Equipment List For Conversion Mv. Yutaka - With Supplier
Equipment List For Conversion Mv. Yutaka - With Supplier
Equipment List For Conversion Mv. Yutaka - With Supplier
MV.YUTAKA
QUANTITY
UNIT/ SET
MODEL REMARKS
NO EQUIPMENT
SPECIFICATION
Supply Equipment by Mr. Joe – China Email: [email protected] Done
By Pak TJ
1 Motor Driven Screw Air Compressor KHAISAN JN335W-6-II / Motor=250KW, 2
Electro Motor 380 Volt 50 Hz Output=62.5CBM
2 Air Dryer for Compressor Capacity 62.5 CBM KSAD-70SW 380-volt 50 Hz 2
3 Receiver Tank + Safety Valve 80A Capacity 5m3 1
4 Plate sea water heat exchanger (140m3)/Hrs 1
For Compressor 2 x 62.5 M3
5 Pneumatic Waver Butterfly Valve 125A JIS 10K (With Actuator Valve) 4
NBR Rubber hardness 80
6 Pneumatic Waver Butterfly Valve 100A JIS 10K (With Actuator Valve) 4
7 Pneumatic Waver Butterfly Valve 200A JIS 10K (With Actuator Valve) 1
8 Pneumatic Waver Butterfly Valve 250A JIS 10K (With Actuator Valve) 4
9 Pneumatic Gate Valve Butterfly 350A JIS 10K (With Piston Actuator Valve) 2
10 Pneumatic Gate Valve 350A JIS 10K Only valve for spare (Not include actuator) 1
11 Tank Receiver capacity 5 M3 with safety valve For Tank receiver blow tank A &B 1
12 Manual Gear Type Butterfly Valve 450A JIS 10K For Loading pneumatic 1 line 1
13 Rubber Hose for Discharge 12-inch JIS 10K Length 6 Meter 4
14 Baby Compressor 1.0 M3/Min 0.12 Mpa 380 Volt 50 Hz 1
15 Air Receiver Tank + Safety Valve 40A Capacity 1 M3 1
16 Pressure Tank (blow tank) Capacity 15M3 Height 4.2 Mtr 2
17 Filter set (Oil Water Separator) For compressor JN335-6-II 6
18 Hydraulic Crane SWL 1.5 Ton Length 12 Meter For Cargo Hose Handling 1
19 Limit switch Box AUTOMA ALS10 Type Mechanical switch 20
AC 16A-125V or 250V DC 0,6A-125V 3A 250V
Supply Equipment by PT. Azbil Berca Indonesia Pic : Panitis , Hp : 085782000096 done
24 Electric pressure transmitter for tank A, B & Tank Azbil Model: SPS300A203A11D 3
receiver Range: 0 – 1000 kpa volt. 220
25 Electric pressure transmitter Azbil Model: PTG60G-G5B1G3-X-X 2
Range: 0 – 2MPa SUPPLY 24VDC
Supply Equipment by PT. CKD TRADING Pic : Andika, Hp : 08111717210 done
INDONESIA
26 Solenoid Valve CKD 4F629-M3L AC 220 volt 50hz For Open / Closed Actuator pneumatic Valve 20
pressure 0.15-1.0 (mpa) (for pneumatic valve)
Supply Equipment by PT. Sinar Mas Sakti Pic : YONO, Tlp : 021-6393408 done
Supply Equipment by TAIKO KIKAI INDUSTRIES Pic : Yamaguchi, Telp : 0820-52 3113 / 3114 done
CO,. LTD Email : [email protected]
36 FW Cooling Pump 140M3/Hour 0,2mpa Lift distance 20 mtr horizontal 55M 1
Elmot 380 Volt 50 hZ