Daikin FBA50BA
Daikin FBA50BA
Daikin FBA50BA
Trusted name
7
Every day we breathe in 10,000 litres of air. It
nourishes us. Enriches us. A deep breath of clean air Daikin technology 8
is exactly what nature intended. It’s amazing that
something we can’t see can make such a difference Premium Inverter Ducted 10
to our health and well-being – and it’s why we
believe every breath should be ‘perfect’. Inverter Ducted 12
At Daikin, we’ve been ‘perfecting the air’ for over 50 FBA Slimline Ducted 14
years to make your home a calm and comfortable
place – for you and your family. FDYBA Bulkhead System 15
Daikin AirHub 16
Features checklist 22
Product specifications 24
2 3
Daikin Daikin Ducted 3 5
Ducted Air Daikin’s exclusive AirFX range of ducted
installation accessories is designed to meet
relevant Australian standards and to ensure your
and AirFX
accessories
Whole house comfort ducted system operates efficiently and reliably.
1
may be lost through the flexible duct network,
impacting both your comfort and power bills.
Comprised of a concealed indoor unit, a
sophisticated zone controller and a compact
7
To get the most out of your ducted system,
outdoor unit, Daikin ducted air conditioning always insist that compliant flexible duct is
provides high-performance comfort without installed with an insulation R-Value* rating
compromising on your home’s overall aesthetic. appropriate to your climate zone. Daikin AirFX
2
flexible duct is also manufactured in Australia,
supporting our local industries.
*R1.0, R1.5 or R2.0 based on the climate zone you’re in and AS/NZS 4254.1 & AS/NZS 4859.1 certified.
4 5
Trusted What is
Name Seasonal
Daikin Ducted -
more for your money
Performance?
Air conditioning units receive seasonal performance ratings which
When you choose a Daikin, you can be confident take into consideration the local climate where the air conditioner
you’ve made a smart choice for your home and is installed and the seasonal temperature differences experienced
your family. throughout the year.
Local after sales service and support The rating system divides Australia into three distinct climate
Daikin has an established Service Department zones; hot, average and cold. Air conditioning systems will perform
including an in-house call centre, spare parts division differently depending on where they’re installed, so it’s important to
and support centre for all technical enquiries. choose the right model for your zone.
AVERAGE
Australian Made Certification
Through our commitment to expand our local
manufacturing capability, all Daikin ducted indoor
units* have received ‘Australian Made’ certification.
TCSPF/HSPF refers to the seasonal efficiency of an air conditioner as outlined in the GEMS 2019 Determination.
TCSPF: Total Cooling Seasonal Performance Factor as per AS/NZS 3823.4.1:2014.
HSPF: Heating Seasonal Performance Factor as per AS/NZS 3823.4.2:2014.
6 7
Daikin For over 90 years, Daikin has invested heavily in Research and
Development to deliver more effective climate control for you and
your family. Daikin technologies help make Daikin air conditioners
Technology
energy efficient, powerful, reliable and easy to use.
Indoor Unit
2 Outdoor Unit 8
3 6
4 7
1 5
1. Indoor heat exchanger 3. Sirocco fan Conventional Inverter 5. Inverter compressor 7. Saw edge fan blade
Our new indoor heat exchangers Daikin’s ducted units are fitted Daikin’s swing and scroll DC sine The addition of a saw tooth edge
have been designed to deliver with lightweight single injection wave inverter compressors are at the rear of the blade smooths
maximum capacity output in a moulded Sirocco Fans. These quieter and more efficient than air flow over the blade surface,
compact casing size. Through fans feature an aerodynamic conventional compressors thanks reducing turbulence which in
the use of cutting-edge fan blade design which reduces to their high pressure dome turn results in a quieter, more
technologies, our indoor heat turbulence for a more efficient construction and the usage of efficient means of delivering
exchangers utilise 5mm copper and quieter delivery. high pressure lubrication oil. comfort to your home.
DC Sine Wave Inverter
pipes to ensure heat is removed
from your home efficiently.
7.1kW 18.0kW
6
R32 MODELS
SINGLE
PHASE
16.0kW
– TO –
CAPACITY RANGE
6
R410A MODELS
THREE
PHASE
24.0kW
– TO –
CAPACITY RANGE
5.0kW 18.0kW
14
R32 MODELS
SINGLE
+
THREE
PHASE OPTIONS
15.5kW
– TO –
CAPACITY RANGE
3
R410A MODELS
THREE
PHASE
– TO –
23.5kW
CAPACITY RANGE
Inverter Ducted
Improved energy performance Expanded 3 phase range Space saving outdoor unit Compact indoor unit
Adopting advanced technologies such as a Designed for homes with a 3 phase power The Inverter series outdoor units are more Today’s modern home designs are maximising
DC Fan motor, Cross-Pass Heat Exchanger on supply in place, our new R32 Inverter series compact than ever before. Models up to 200 living spaces with higher ceilings resulting
the outdoor unit with increased heat exchange ensures a simple and convenient installation Class are now encased in a space saving side in shallower roof spaces. Our Inverter series
area and Daikin’s patented swing compressor, without the need to worry about unbalanced discharge outdoor unit, allowing you to place features compact indoor units with a low
our new Inverter series is designed to operate electrical loads at your electrical distribution the unit on the side access of your home and profile height of ≤360mm allowing them to fit
with improved efficiencies throughout the year. board. not compromise its external appearance. comfortably into modern homes.
Ducted System
5.0kW 2.5kW
15
R32 MODELS
SINGLE
+
THREE
PHASE OPTIONS
14.0kW
– TO –
CAPACITY RANGE
5
R32 MODELS
SINGLE
PHASE
7.1kW
– TO –
CAPACITY RANGE
*BDG20A09A1 for 25 Class, BDG20A15A1 for 35-50 Class & BDG20A20A1 for 60-71
Class. Only compatible with BRC1E63 controller.
^BAE20A62 for 25 Class, BAE20A82 for 35-50 Class & BAE20A102 for 60-71 Class (all
Note: R
32 ducted indoor units must be installed in the ceiling space. models extend depth by 188mm). Only compatible with BRC1E63 controller.
Not suitable for under floor installation. Note: R32 Bulkhead indoor units are not suitable for under floor installation.
14 15
Daikin’s AirHub Touch Zone Controller with its contemporary design,
intuitive controls and innovative features will give you the flexibility to
deliver precise temperature control and ultimate comfort where it is AirHub comes in two versions
needed in your home.
1. ON/OFF ZONE CONTROL* 2. LINEAR ZONE CONTROL**
Allows users to air-condition occupied zones Enables users to switch zones on and off as
and switch off unoccupied zones. Features well as set the zone temperature to within
Airside Control. ±2°C. Features Opti-Zone Control.
Zone 1
ON 22°C
22°C
Zone 4
OFF
Example: Example:
Temperature set Main temperature
point @ 22º C in set point @ 22º C 23°C
all ON zones with a ±2º C range
Daikin AirHub *Only compatible with all Premium Inverter and Inverter Ducted models, however Airside Control feature is not available on R410A (FDYQN) Inverter Ducted models.
**Only compatible with R32 (FDYA) Premium Inverter and R32 (FDYAN) Inverter Ducted models.
16 17
At Daikin, we have a range of other controllers
available to control your ducted air conditioning
system to suit your lifestyle needs.
Standard
controllers
Zone Controller (On/Off Control Only) Nav Ease Controller
Features Features
Notes:
1. Premium Inverter, Inverter & Slim-Line Ducted models are compatible with Nav Ease & Zone Controller, Bulkhead models are only compatible with Nav Ease Controller
2. Airside Control function regulates the fan RPM between 60% to 100% of the indoor unit’s nominal airflow rate
3. Airbase is not compatible with Sub Zone Controller
18 19
Operation Push On/off Zone
mode notification Timer Control
Smart home
With Daikin Airbase your ducted system can “Hey Google,
now be part of the Google and Amazon home turn on
automation ecosystem alongside 3rd party the aircon”
supplied lights, garage doors, security systems etc.
Daikin
Airbase
Features
DUCTED/ DUCTED WITH DUCTED WITH
FUNCTION BULKHEAD ON/OFF ZONE LINEAR ZONE
Three ways to connect
Control at your fingertips
WITH NAV EASE CONTROL CONTROL
Start/stop operation P P P
Temperature setting P P P
1. Direct connection
Fan speed settings P P O
Daikin Airbase puts your ducted system’s frequently used For locations without a Wi-Fi network, the app can
Mode selection
functions at your fingertip with an easy-to-use app. P P P wirelessly connect directly to a WLAN adaptor equipped
(cool/heat/fan/dry)
air conditioner, when in range.
Zone on/off O P P
In conjunction with Daikin’s BRP15B61 wireless LAN adaptor,
Zone Temperature (±2º C)
the Airbase app lets you use your smartphone or tablet* to O O P
2. Wi-Fi connection
operate your air conditioning unit via your in-home Wi-Fi or 24 hour on/off timer P P P A WLAN adaptor equipped air conditioner can easily
remotely with an internet connection. Enter zone names O P P be joined to a local Wi-Fi network. Once connected, the
Error notification P P P system can be controlled from any networked Android
Up to 10 systems** can be conveniently monitored and Room temperature
P P P
or iOS device.
controlled on the app anywhere, anytime. display
Filter clean reminder P P P 3. Internet connection
Push notification
P P P
Monitor and control your system from virtually anywhere,
(on/off alerts) adjusting temperature and setting for a comfortable
Automatic adaptor
P P P
environment ready for when you arrive home. With no
firmware update subscription costs from Daikin, all you need is a permanent
Setup Wizard in app P P P internet connection for your Wi-Fi network, and an internet
connection for your phone or tablet.
*Only compatible with Android (≥ 5.0) & iOS (≥ 8.0) devices and in portrait orientation only
**Each ducted system requires a BRP15B61 adaptor & must be connected on the same Wi-Fi network
20 21
Features checklist Features and benefits
PREMIUM
INVERTER
(71-160 CLASS)
PREMIUM
INVERTER
(180-250 CLASS)
SLIMLINE BULKHEAD INVERTER
(50-160 CLASS)
INVERTER
(180-250 CLASS) Energy efficiency Comfort control
FDYA71AV1 FDYQ180LCV1 FBA50BAVMA FDYBA25AV1 FDYAN50AV1 FDYQN180LCV1 Inverter operation Night Quiet Mode
FDYA85AV1 FDYQ200LCV1 FBA60BAVMA FDYBA35AV1 FDYAN60AV1 FDYQN200LCV1 An inverter system works like the accelerator of a car, Outdoor unit noise is automatically reduced by 3dB when
FDYA100AV1 FDYQ250LCV1 FBA71BVMA FDYBA50AV1 FDYAN71AV1 FDYQN250LBV1
FDYA125AV1 FBA85BVMA FDYBA60AV1 FDYAN85AV1 gently increasing or decreasing power to steadily outdoor temperatures fall more than 6˚C from the day’s
FDYA140AV1 FBA100BVMA FDYBA71AV1 FDYAN100AV1 maintain your optimum temperature without maximum (set during installation).
FDYA160AV1 FBA125BVMA FDYAN125AV1
FBA140BVMA FDYAN140AV1 fluctuations. That means uninterrupted comfort and
FDYAN160AV1 significant savings on running costs. Daikin Premium Program Dry Mode
Inverter Operation Inverters can also reach your desired temperature faster In this mode, priority is given to reducing the level of
DC Indoor Fan Motor than conventional air conditioners. humidity in the room rather than room temperature.
Swing Compressor
Automatic mode changeover Intelligent Defrost
Scroll Compressor
Automatically selects heating or cooling modes to suit During heating operation in low ambient temperature
High Efficiency Indoor Heat
Exchanger Coil
thermostat settings and prevailing room temperature. conditions, frost can form on the outdoor unit heat
exchanger which can reduce your air conditioner’s
Automatic Mode Changeover
Predicted Mean Vote (PMV) Control performance. Daikin’s Intelligent Defrost system constantly
P.M.V. Control Operations
Measures indoor and outdoor temperatures to calculate monitors a range of system parameters and temperatures
Temperature Limit Operations 1 1 1 1 1 the ideal room temperature, gently adjusting it for the to determine the optimum time to commence a defrost
Home Leave 1 1 1 1 1 optimum balance between efficiency and comfort. operation for maximum performance in cold conditions.
Auto Restart After Power Failure
Self Diagnostics
Temperature limit operations Hot start
Anti-Corrosion Coating for Outdoor
Lets you pre-define temperature range for cooling or Prior to heating, the indoor unit warms to a pre-set
Heat Exchanger
heating, to reduce energy consumption. temperature before the fan switches on, ensuring only
Indoor Unit Designed and warm air is discharged, eliminating cold drafts.
Built in Australia Home Leave
Long Piping Length Ideal for cold climates, Home Leave turns your air Quick cool/heat - Powerful Mode
High Strength Galvanized
conditioner on automatically when room temperatures This feature temporarily increases power to more rapidly
Steel Casing drop below 10˚C, keeping your home at or above 10˚C reach your desired room temperature, before automatically
Night Quiet Mode 2 2 2 2 2 2 so it never gets really cold. returning to normal operation.
Low Noise Operation 3
3
3
3
3
Program Dry Mode
Intelligent Defrost
Hot Start
Automatic functions Timer control
Quick Cool / Heat
– Powerful Mode
Auto restart after power failure 24 hour on/off timer
The air conditioner memorises the settings for mode, This timer can be pre-set to start and stop at any time
Automatic Fan Speed
airflow, temperature etc. and automatically returns to within a 24 hour period.
Automatic Airflow Adjustment 4 them when power is restored after a power failure.
Indoor Fan Cycles with Compressor 5 5 5 5 5 Night Set Mode
24 Hour On/Off Timer Self diagnosis with digital display A timer off circuit gradually adjusts pre-set cooling and
Night Set Mode 2 Malfunction codes are displayed on your control panel heating levels, preventing sudden temperature changes
Seven Day Time Clock
for fast, easy fault diagnosis and maintenance. during the night and improving economy.
Electronic Control System
Anti-corrosion coating Seven day time clock
Airside Control 6
6
6
An anti-corrosion coating on outdoor heat exchangers This allows you to program your air conditioner to turn on
OptiZone Control 7 7 gives greater resistance to salt damage and or off at set times for every day of the week.
Wireless LAN Connection 8 8 8 10 8 8 atmospheric corrosion.
R22 Retrofit Capability 9
Auto Clean Air Filter Module
Compact design
10
The compact design of Daikin ducted indoor units
3-D Auto Swing Grille 10 allows them to be installed in confined areas, and they
Demand Enabled Response (DRED) 11 11 11 11 11 11 can also be dismantled for easier installation in tight
1 7
roof spaces.
Only available on Nav Ease Only available on AirHub Linear Controller
2 8
Night Quiet & Night Set modes may reduce capacity Optional accessory & only compatible with Nav Ease or Zone Controller
3 9
Low Noise Operation requires optional PCB Only available when connected to RZYQ-TY1
4 10
Only available on FDYQN180-200LCV1 Optional accessory & only compatible with Nav Ease Controller
5 11
Can be set up by installer during installation Optional accessory, compliant to AS/NZS 4755.3.1:2012
6
Only available on AirHub On/Off Zone Controller & Zone Controller Note: Not all features available on all models. Please refer to checklist on page 22
22 23
Product Specification Product Specification
Premium Inverter - Single Phase Premium Inverter - Three Phase
RZYQ7T
RZAS100C RZYQ8T
RZAS125C RZYQ10T
RZAS140C RZYQ7TA
RZAS160C RZYQ8TA
RZYQ10TA
RZAS71C
RZAS85C
FDYQ180LC
FDYQ200LC
FDYQ250LC
FDYA71A
FDYA85A FDYA140A
FDYA100A FDYA125A FDYA160A
INDOOR UNIT FDYA71AV1 FDYA85AV1 FDYA100AV1 FDYA125AV1 FDYA140AV1 FDYA160AV1 INDOOR UNIT FDYQ180LCV1 FDYQ200LCV1 FDYQ250LCV1 FDYQ180LCV1 FDYQ200LCV1 FDYQ250LCV1
OUTDOOR UNIT RZAS71CV1 RZAS85CV1 RZAS100CV1 RZAS125CV1 RZAS140CV1 RZAS160CV1 OUTDOOR UNIT RZYQ7TY1 RZYQ8TY1 RZYQ10TY1 RZYQ7TAY1 RZYQ8TAY1 RZYQ10TAY1
Cool (kW) 7.1 8.5 10.0 12.5 14.0 16.0 Cool (kW) 18.0 20.0 24.0 18.0 20.0 24.0
Rated Capacity Rated Capacity
Heat (kW) 7.5 10.0 12.5 15.0 16.5 18.0 Heat (kW) 20.0 22.4 26.8 20.0 22.4 26.8
Cool (kW) 3.2-8.0 4.0-10.0 5.0-11.2 5.0-14.0 5.0-16.0 7.3-17.0 Cool (kW) 9.0-20.0 10.0-22.4 11.7-24.0 9.0-20.0 10.0-22.4 11.7-24.0
Capacity Range Capacity Range
Heat (kW) 3.5-9.0 4.1-11.2 5.1-14.0 5.1-16.0 5.1-18.0 7.3-20.0 Heat (kW) 10.0-22.4 11.2-25.0 13.4-26.8 10.0-22.4 11.2-25.0 13.4-26.8
Cool (kW) 1.90 2.35 2.61 3.45 3.93 4.85 Cool (kW) 5.61 6.08 7.47 5.61 6.08 7.47
Power Input (Rated) Power Input (Rated)
Heat (kW) 1.75 2.46 3.13 3.80 4.28 4.65 Heat (kW) 5.81 6.17 8.14 5.81 6.17 8.14
E.E.R/C.O.P C/H 3.74/4.29 3.62/4.07 3.83/3.99 3.62/3.95 3.56/3.86 3.30/3.87 E.E.R/C.O.P C/H 3.21/3.44 3.29/3.63 3.21/3.29 3.21/3.44 3.29/3.63 3.21/3.29
TCSPF (Residential) Hot/Average/Cold 5.21/4.52/4.58 4.90/4.32/4.39 4.69/4.23/4.27 4.57/4.18/4.26 5.00/4.55/4.69 4.77/4.38/4.56 TCSPF (Residential) Hot/Average/Cold - - - 3.79/3.23/3.19 3.86/3.32/3.29 3.97/3.48/3.48
HSPF (Residential) Hot/Average/Cold 3.87/3.80/3.51 4.20/3.95/3.54 4.43/4.07/3.62 4.43/3.92/3.36 4.11/3.67/3.16 3.96/3.65/3.21 HSPF (Residential) Hot/Average/Cold - - - 3.21/3.15/3.02 3.42/3.35/3.20 3.60/3.37/3.15
Airflow Rate (Nominal/Max) l/s 425/566 580/600 680/800 755/840 900/1000 950/1120 Airflow Rate (Nominal/Max) l/s 1160/1200 1200/1300 1400/1600 1160/1200 1200/1300 1400/1600
Indoor Sound Level (H) @ 1.5m dBA (C/H) 37.3/40.5 42.0/42.5 42.3/45.0 44.8/46.2 45.9/47.4 47.2/49.6 Indoor Sound Level (H) @1.5m dBA (C/H) 45.0/45.0 44.0/44.0 46.0/46.0 45.0/45.0 44.0/44.0 46.0/46.0
Piping Length m 75 Piping Length m 150 165
Indoor Fan Speeds H/M/L Indoor Fan Speeds H/M/L
Indoor (mm) 300x1210x900 360x1520x935 400x1505x980 Indoor (mm) 470x1200x997 470x1400x997 470x1200x997 470x1400x997
Dimensions (HxWxD) Dimensions (HxWxD)
Outdoor (mm) 990x940x320 1430x940x320 Outdoor (mm) 1657x930x765
Indoor (kg) 40 41 46 56 60 60 Indoor (kg) 70 79 85 70 79 85
Weight Weight
Outdoor (kg) 69 78 93 93 93 99 Outdoor (kg) 192 192 203 185 185 200
Power Supply V/Hz 1 Phase, 220-240V, 50Hz Power Supply V/Hz 3 Phase, 380-415V, 50Hz
Compressor Type Hermetically Sealed Swing Type Compressor Type Hermetically Sealed Scroll Type
Refrigerant R32 Refrigerant R410A
Liquid (mm) 9.5 (Flared) Liquid (mm) 9.5 (Brazed)
Pipe Sizes Gas (mm) 15.9 (Flared) Pipe Sizes Gas (mm) 19.1 (Brazed) 22.2 (Brazed) 19.1 (Brazed) 22.2 (Brazed)
Drain (mm) ID 25 / OD 32 Drain (mm) BSP 3/4 inch Internal Thread BSP 3/4 inch Internal Thread
Supply Air Opening mm (HxW, Flange) 185x852 245x1152 295x1152 Supply Air Opening mm (HxW, Flange) 350x918 350x1118 350x918 350x1118
Return Air Opening mm 1x400 (Oval) 2x350 (Oval) 2x400 (Oval) Return Air Opening mm 393x918 (Flange) 393x1118 (Flange) 393x918 (Flange) 393x1118 (Flange)
Cool (º CDB) -5 to 50 Cool (º CDB) -5 to 49
Outdoor Operating Range Outdoor Operating Range
Heat (º CWB) -15 to 16 Heat (º CWB) -20 to 16
EPA Sound Power Level dBA 67 71 70 71 73 75 EPA Sound Power Level dBA - - - 76 76 78
Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) 48/50 52/53 51/53 52/54 54/56 56/58 Outdoor Sound Level (H) @1m Pressure dBA (C/H) 56/56 56/56 57/57 56/56 56/56 57/57
Notes: Notes:
i. The Rated Capacity, Power Input and Running Current are measured in accordance with AS/NZS 3823.1.2 i. The Rated Capacity, Power Input and Running Current are measured in accordance with AS/NZS 3823.1.2
Cooling: Indoor temp: 27ºCDB/19ºCWB, Outdoor temp: 35ºCDB/24ºCWB Cooling: Indoor temp: 27º CDB/19 º CWB, Outdoor temp: 35º CDB/24º CWB
Heating: Indoor temp: 20ºCDB/15ºCWB, Outdoor temp: 7ºCDB/6ºCWB Heating: Indoor temp: 20 º CDB/15º CWB, Outdoor temp: 7º CDB/6º CWB
ii. Indoor and outdoor sound levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions ii. Indoor and outdoor sound levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions
iii. TCSPF: Total Cooling Seasonal Performance Factor & HSPF: Heating Seasonal Performance Factor as defined under GEMS 2019 Determination iii. TCSPF: Total Cooling Seasonal Performance Factor & HSPF: Heating Seasonal Performance Factor as defined under GEMS 2019 Determination
iv. R32 ducted indoor units must be installed in the ceiling space, it is not to be installed under floor iv. R32 ducted indoor units must be installed in the ceiling space, it is not to be installed under floor
24 25
Product Specification Product Specification
Inverter - Single Phase Inverter - Three Phase
RZA140C
RZA160C
RZA140C
RZA85C RZA160C
RZA100C RZQ180M RZQ250L
RZA125C RZA71C RZQ200M
RZA50C RZA85C
RZA60C RZA100C
RZA71C RZA125C
FDYAN50A FDYQN250LB
FDYAN60A FDYAN71A FDYAN125A RZQ250L
FDYAN71A FDYAN125A FDYAN85A FDYAN140A FDYQN180LC
FDYAN85A FDYAN140A FDYAN100A FDYAN160A FDYQN200LC
FDYAN100A FDYAN160A
INDOOR UNIT FDYAN50AV1 FDYAN60AV1 FDYAN71AV1 FDYAN85AV1 FDYAN100AV1 FDYAN125AV1 FDYAN140AV1 FDYAN160AV1 INDOOR UNIT FDYAN71AV1 FDYAN85AV1 FDYAN100AV1 FDYAN125AV1 FDYAN140AV1 FDYAN160AV1 FDYQN180LCV1 FDYQN200LCV1 FDYQN250LBV1
OUTDOOR UNIT RZA50CV1 RZA60CV1 RZA71CV1 RZA85CV1 RZA100CV1 RZA125CV1 RZA140CV1 RZA160CV1 OUTDOOR UNIT RZA71CY1 RZA85CY1 RZA100CY1 RZA125CY1 RZA140CY1 RZA160CY1 RZQ180MY1 RZQ200MY1 RZQ250LY1
Cool (kW) 5.0 6.0 7.1 8.5 10.0 12.5 14.0 15.5 Cool (kW) 7.1 8.5 10.0 12.5 14.0 15.5 18.0 19.5 23.5
Rated Capacity Rated Capacity
Heat (kW) 6.0 7.0 7.5 10.0 12.5 15.0 16.5 18.0 Heat (kW) 7.5 10.0 12.5 15.0 16.5 18.0 20.0 22.4 26.8
Cool (kW) 1.4-6.0 1.4-7.1 1.8-8.0 3.2-10.0 3.2-11.2 4.0-14.0 5.0-16.0 7.3-16.3 Cool (kW) 3.2-8.0 3.2-10.0 3.2-11.2 4.0-14.0 5.0-16.0 7.3-16.3 9.0-18.0 10.1-19.5 15.0-23.5
Capacity Range Capacity Range
Heat (kW) 1.4-7.1 1.4-8.0 2.0-9.0 3.5-11.2 3.5-14.0 4.1-16.0 5.1-18.0 7.3-18.2 Heat (kW) 3.5-9.0 3.5-11.2 3.5-14.0 4.1-16.0 5.1-18.0 7.3-18.2 10.0-20.0 11.2-22.4 16.8-26.8
Cool (kW) 1.35 1.78 2.20 2.53 3.10 3.94 4.30 4.95 Power Input Cool (kW) 2.20 2.53 3.10 3.94 4.30 4.95 5.82 6.11 7.85
Power Input (Rated)
Heat (kW) 1.62 1.95 1.93 2.80 3.35 4.00 4.50 4.90 (Rated) Heat (kW) 1.93 2.80 3.35 4.00 4.50 4.90 6.11 6.85 8.47
E.E.R/C.O.P C/H 3.70/3.70 3.37/3.59 3.23/3.89 3.36/3.57 3.23/3.73 3.17/3.75 3.26/3.67 3.13/3.67 E.E.R/C.O.P C/H 3.23/3.89 3.36/3.57 3.23/3.73 3.17/3.75 3.26/3.67 3.13/3.67 3.09/3.27 3.19/3.27 2.99/3.16
Hot/Average/ Hot/Average
TCSPF (Residential) 4.43/3.74/3.68 4.36/3.77/3.78 4.43/3.88/3.94 4.29/3.85/3.90 4.28/3.88/3.97 4.26/3.91/4.02 4.19/3.87/3.97 4.05/3.76/3.87 TCSPF (Residential) 4.44/3.92/4.00 4.29/3.85/3.90 4.28/3.88/3.97 4.26/3.91/4.02 4.19/3.87/3.97 4.05/3.76/3.87 3.61/3.15/3.13 3.57/3.14/3.11 3.73/3.41/3.46
Cold /Cold
Hot/Average
Hot/Average/ HSPF (Residential) 4.17/3.90/3.55 3.97/3.67/3.32 3.85/3.48/3.04 4.31/3.31/2.77 3.90/3.51/3.05 3.87/3.53/3.12 3.23/2.95/2.61 3.25/2.97/2.63 3.41/3.08/2.72
HSPF (Residential) 4.51/4.02/3.49 4.46/3.76/3.15 4.17/3.85/3.41 3.97/3.67/3.32 3.85/3.48/3.04 4.31/3.31/2.77 3.90/3.51/3.05 3.87/3.53/3.12 /Cold
Cold
Airflow Rate
l/s 425/566 580/600 680/800 755/840 900/1000 950/1120 1160/1200 1400/1600 1400/1600
Airflow Rate (Nominal/Max)
l/s 315/370 340/400 425/566 580/600 680/800 755/840 900/1000 950/1120
(Nominal/Max)
Indoor Sound
dBA (C/H) 37.3/40.5 42.0/42.4 43.5/45.8 44.2/45.5 46.6/47.9 47.9/50.7 45.0/45.0 46.0/46.0 49.5/49.5
Level (H) @1.5m
Indoor Sound
dBA (C/H) 33.3/35.0 34.1/35.9 37.3/40.5 42.0/42.4 43.5/45.8 44.2/45.5 46.6/47.9 47.9/50.7 Piping Length m 50
Level (H) @1.5m
Indoor Fan Speeds H/M/L
Piping Length m 50
Dimensions Indoor (mm) 300x1210x900 360x1520x935 470x1200x997 470x1400x997 500x1430x970
Indoor Fan Speeds H/M/L
(HxWxD) Outdoor (mm) 990x940x320 1430x940x320 1680x930x765
Dimensions Indoor (mm) 300x1210x900 360x1520x935
Indoor (kg) 40 40 45 55 55 56 70 85 92
(HxWxD) Outdoor (mm) 595x845x300 990x940x320 1430x940x320 Weight
Outdoor (kg) 69 69 69 78 93 99 138 138 193
Indoor (kg) 37 37 40 40 45 55 55 56
Weight Power Supply V/Hz 3 Phase, 380-415V, 50Hz
Outdoor (kg) 45 45 45 69 69 78 93 99
Compressor Type Hermetically Sealed Swing Type Hermetically Sealed Scroll Type
Power Supply V/Hz 1 Phase, 220-240V, 50Hz
Refrigerant R32 R410A
Compressor Type Hermetically Sealed Swing Type
Liquid (mm) 9.5 (Flare) 9.5 (Brazed)
Refrigerant R32
Pipe Sizes Gas (mm) 15.9 (Flare) 19.1 (Brazed) 22.2 (Brazed)
Liquid (mm) 6.4 (Flare) 9.5 (Flare)
Drain (mm) ID 25/OD 32 BSP 3/4 inch Internal Thread
Pipe Sizes Gas (mm) 12.7 (Flare) 15.9 (Flare)
Supply Air mm (HxW,
Drain (mm) ID 25 / OD 32 185x852 245x1152 350x918 350x1118 376x938
Opening Flange)
mm (HxW,
Supply Air Opening 185x852 245x1152 Return Air 393x918 393x1118 350x1118
Flange) mm 1x400 (Oval) 2x350 (Oval) 2x400 (Oval)
Opening (Flange) (Flange) (Flange)
Return Air Opening mm 1x400 (Oval) 2x350 (Oval) 2x400 (Oval)
Outdoor Cool (º CDB) -5 to 46 -5 to 43
Outdoor Cool (º CDB) -5 to 46 Operating Range Heat (º CWB) -15 to 16 -20 to 16
Operating Range Heat (º CWB) -15 to 16
EPA Sound
dBA 67 70 71 72 73 75 72 74 79
EPA Sound Power Level
dBA 68 68 68 70 71 72 73 75
Power Level Outdoor Sound Pressure
48/50 51/54 52/54 53/56 54/56 56/58 57/58 58/59 57/58
Level (H) @1m dBA (C/H)
Outdoor Sound Pressure dBA
48/51 48/51 48/51 51/54 52/54 53/56 54/56 56/58
Level (H) @1m (C/H)
Notes: Notes:
i. The Rated Capacity, Power Input and Running Current are measured in accordance with AS/NZS 3823.1.2 i. The Rated Capacity, Power Input and Running Current are measured in accordance with AS/NZS 3823.1.2
Cooling: Indoor temp: 27º CDB/19 º CWB, Outdoor temp: 35º CDB/24º CWB Cooling: Indoor temp: 27º CDB/19 º CWB, Outdoor temp: 35º CDB/24º CWB
Heating: Indoor temp: 20 º CDB/15º CWB, Outdoor temp: 7º CDB/6º CWB Heating: Indoor temp: 20 º CDB/15º CWB, Outdoor temp: 7º CDB/6º CWB
ii. Indoor and outdoor sound levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions ii. Indoor and outdoor sound levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions
iii. TCSPF: Total Cooling Seasonal Performance Factor & HSPF: Heating Seasonal Performance Factor as defined under GEMS 2019 Determination iii. TCSPF: Total Cooling Seasonal Performance Factor & HSPF: Heating Seasonal Performance Factor as defined under GEMS 2019 Determination
iv. R32 ducted indoor units must be installed in the ceiling space, it is not to be installed under floor iv. R32 ducted indoor units must be installed in the ceiling space, it is not to be installed under floor
26 27
Product Specification Product Specification
FBA - Single Phase FBA - Three Phase
RZAV71C RZAV100F
RZAV85C RZAV125F RZAV71C RZAV100F
RZAV50C RZAC85C RZAV140F RZAV85C RZAV125F
RZAV60C RZAC85C RZAV140F
FBA85B
FBA50BA FBA100B RZAC71C
FBA60BA FBA125B
FBA71B FBA140B FBA85B
FBA100B
FBA71B FBA125B
FBA140B
Notes: Notes:
i. The Rated Capacity, Power Input and Running Current are measured in accordance with AS/NZS 3823.1.2 i. The Rated Capacity, Power Input and Running Current are measured in accordance with AS/NZS 3823.1.2
Cooling: Indoor temp: 27º CDB/19 º CWB, Outdoor temp: 35º CDB/24º CWB Cooling: Indoor temp: 27º CDB/19 º CWB, Outdoor temp: 35º CDB/24º CWB
Heating: Indoor temp: 20 º CDB/15º CWB, Outdoor temp: 7º CDB/6º CWB Heating: Indoor temp: 20 º CDB/15º CWB, Outdoor temp: 7º CDB/6º CWB
ii. Indoor and outdoor sound levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions ii. Indoor and outdoor sound levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions
iii. TCSPF: Total Cooling Seasonal Performance Factor & HSPF: Heating Seasonal Performance Factor as defined under GEMS 2019 Determination iii. TCSPF: Total Cooling Seasonal Performance Factor & HSPF: Heating Seasonal Performance Factor as defined under GEMS 2019 Determination
iv. R32 ducted indoor units must be installed in the ceiling space, it is not to be installed under floor iv. R32 ducted indoor units must be installed in the ceiling space, it is not to be installed under floor
28 29
Product Specification
FDYBA - Single Phase
RZAC50G
RZAC60G RZAC71G
FDYBA25A RZAC25G
FDYBA35A RZAC35G
FDYBA50A
FDYBA60A
FDYBA71A
Pipe Sizes
Liquid (mm)
Gas (mm)
6.4 (Flared)
9.5 (Flared)
Hermetically Sealed Swing Type
R32
6.4 (Flared)
12.7 (Flared)
Specialist Dealer?
Drain (mm) ID 20 / OD 26
Like us, our Dealers are specialists. They To take the stress out of air conditioning your
Supply Air Opening mm (HxW, Flange) 153x660 153x860 153x1060
know the ups and downs, ins and outs of air home, speak to a Daikin Specialist Dealer. With
Return Air Opening mm (HxW, Flange) 163x575 163x775 163x975
conditioning. So their expertise ensures you over 450 Specialist Dealers across Australia, our
Cool (°CDB) -10 to 50 get the right advice for your needs. specialists are ready to help you fit the right air
Outdoor Operating Range
Heat (°CWB) -15 to 18 conditioning solution for your home.
EPA Sound Power Level dBA 60 60 62 63 67 Daikin Specialist Dealers provide custom
Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) 45/48 47/48 47/50 48/51 53/55 designed solutions for your home through All appointed Daikin Specialist Dealers
an in-home quotation. Dealers will not are independently owned and operated
only supply and install the best possible air businesses.
conditioning solution but will also provide
ongoing maintenance to ensure peak efficient
performance over the life of the system.
Notes:
i. The Rated Capacity, Power Input and Running Current are measured in accordance with AS/NZS 3823.1.2
Cooling: Indoor temp: 27º CDB/19 º CWB, Outdoor temp: 35º CDB/24º CWB
Heating: Indoor temp: 20 º CDB/15º CWB, Outdoor temp: 7º CDB/6º CWB
ii. Indoor and outdoor sound levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions
iii. TCSPF: Total Cooling Seasonal Performance Factor & HSPF: Heating Seasonal Performance Factor as defined under GEMS 2019 Determination
iv. R32 bulkhead indoor units must be installed in the ceiling space, it is not to be installed under floor
30 31
© Copyright in the contents of this brochure is ENVIRONMENTAL CERTIFICATIONS
owned by Daikin Australia Pty Limited and no part Daikin Industries Limited has received ISO 14001 Environmental
of the document may be reproduced in any form Certification for the Daikin production facilities listed below. ISO
without the express written permission of Daikin
14001 is an international standard specifying requirement for an
Australia Pty Limited.
environmental management system, enabling an organisation to
ASSUMPTIONS formulate policy and objectives, taking into account legislative
All representations made in Daikin marketing and requirements and information about significant environmental
promotional material arebased on the assumptions that impacts. It applies to those environmental aspects within the
the correct equipment has been selected, appropriately organisation’s control and over which it can be expected to have
sized and installed in accordance with Daikin’s an influence.
installation instructions and standard industry practices. The certification relates only to the environmental management
system and does not constitute any endorsement of the products
QUALITY CERTIFICATIONS shipped from the facility by the International Organisation for
Daikin Industries Limited was the first air conditioning Standardisation.
equipment manufacturer in Japan to receive ISO Head Office / Tokyo Office Certificate number: EC02J0355
9001 certification. All Daikin manufacturing facilities Shiga Plant (Japan) Certificate number: EC99J2044
have been certified to ISO 9001 Quality Management Sakai Plant (Japan) Certificate number: JQA-E-80009
System requirements. ISO 9001 is a certificate for Daikin Industries Ltd (Thailand) Certificate number: JQA-E-90108
quality assurance concerning ‘design, development, Yodogawa Plant (Japan) Certificate number: EC99J2057
manufacturing, installation and related service’ of Daikin Australia Pty. Ltd. Certificate number: CEM20437
products manufactured at that factory.
Commercial Air Conditioning May 12, 2006 February 2021 October 27, 2006
and Refrigeration Sydney, Brisbane, Adelaide, Sydney Sydney, Brisbane, Adelaide,
Manufacturing Div (ISO 9001) Melbourne, Newcastle, Melbourne, Perth
JMI0107 December 28, 1992 Townsville, Perth
(Kanaoka Factory and Rinkai
Factory at Sakai Plant)
Industrial System and Chiller Daikin Europe N.V (ISO 9001)
Products Manufacturing Div Lloyd 928589.1 June 2, 1993
(ISO 9001)
JQA-0495 May 16, 1994 Daikin Industries (Thailand) Ltd
(Yodogawa Plant and Kanaoka JQA-1452 September 13, 2002
Factory and Kishiwada Factory) (ISO 9001)
CONTACT