mib Alarm_CXP2020013_1 Page 1 sur 49

Managed Object Model        2418/155 54-LZA 701 6014/4-V1 Uen BT

Instances in

Management Information Base

Alarm_CXP2020013_1

Fm=1
    +-FmAlarmModel=1
        +-FmAlarmType=AggregatedEthernetLinkFailure

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId AggregatedEthernetLinkFailure
isStateful true
majorType 193
minorType 9175188
moClasses LagPort
probableCause m3100LossOfSignal (8)
specificProblem Aggregated Ethernet Link Failure

        +-FmAlarmType=AlternateOAMConnectionInUse

Name Value
additionalText A management session is utilizing the 
alternate connection service
eventType communicationsAlarm (2)
fmAlarmTypeId AlternateOAMConnectionInUse
isStateful true
majorType 193
minorType 9175162
moClasses OamAccessPoint
probableCause x733CommunicationsProtocolError (305)
specificProblem Alternate Oam Connection In Use

        +-FmAlarmType=AntennaCalibrationFailure

Name Value
additionalText
defaultSeverity MINOR
eventType processingErrorAlarm (4)
fmAlarmTypeId AntennaCalibrationFailure

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 2 sur 49

Name Value
isStateful true
majorType 193
minorType 9175211
moClasses SectorCarrier
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Antenna Calibration Failure

        +-FmAlarmType=AntennaConnectionProblem

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId AntennaConnectionProblem
isStateful true
majorType 193
minorType 9175184
moClasses RfPort
probableCause x733EquipmentMalfunction (315)
specificProblem Antenna Connection Problem

        +-FmAlarmType=ArchiveDiskAlmostFull

Name Value
additionalText Export and remove backups, remove upgrade 
packages and export logs to prevent data 
loss.
defaultSeverity WARNING
eventType other (1)
fmAlarmTypeId ArchiveDiskAlmostFull
isStateful true
majorType 193
minorType 9175161
moClasses SystemFunctions
probableCause m3100StorageCapacityProblem (151)
specificProblem Archive Disk Almost Full

        +-FmAlarmType=AutoExportBackupFailed

Name Value
additionalText Export failed. For more information check the 
progress report for the specific backup
defaultSeverity WARNING
eventType other (1)
fmAlarmTypeId AutoExportBackupFailed
isStateful true

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 3 sur 49

Name Value
majorType 193
minorType 9175045
moClasses BrmBackupScheduler
probableCause x736UnspecifiedReason (418)
specificProblem Auto Export Backup Failed

        +-FmAlarmType=AutonomousModeActivated

Name Value
additionalText Autonomous Mode has been activated
eventType communicationsAlarm (2)
fmAlarmTypeId AutonomousModeActivated
isStateful true
majorType 193
minorType 9175049
moClasses AutonomousMode
probableCause x733CommunicationsSubsystemFailure (306)
specificProblem Autonomous Mode Activated

        +-FmAlarmType=BatteryBackupTimeTooShort

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId BatteryBackupTimeTooShort
isStateful true
majorType 193
minorType 9175080
moClasses BatteryBackup
probableCause m3100BatteryFailure (105)
specificProblem Battery Backup Time Too Short

        +-FmAlarmType=BatteryDisconnected

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId BatteryDisconnected
isStateful true
majorType 193
minorType 9175122
moClasses BatteryBackup
probableCause m3100ExternalIfDeviceProblem (54)
specificProblem Battery Disconnected

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 4 sur 49

        +-FmAlarmType=BatteryFailureBatteryDisconnected

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId BatteryFailureBatteryDisconnected
isStateful true
majorType 193
minorType 9175158
moClasses BatteryBackup
probableCause gsm1211BatteryBreakdown (504)
specificProblem Battery Failure Battery Disconnected

        +-FmAlarmType=BatteryMissing

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId BatteryMissing
isStateful true
majorType 193
minorType 9175081
moClasses BatteryBackup
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Battery Missing

        +-FmAlarmType=BatteryVoltageTooLowMainLoadDisconnected

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId BatteryVoltageTooLowMainLoadDisconnected
isStateful true
majorType 193
minorType 9175082
moClasses PowerDistribution
probableCause x733EquipmentMalfunction (315)
specificProblem Battery Voltage Too Low Main Load 
Disconnected

        +-FmAlarmType=BatteryVoltageTooLowPrioLoadDisconnected

Name Value
additionalText
eventType equipmentAlarm (5)

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 5 sur 49

Name Value
fmAlarmTypeId BatteryVoltageTooLowPrioLoadDisconnected
isStateful true
majorType 193
minorType 9175083
moClasses PowerDistribution
probableCause x733EquipmentMalfunction (315)
specificProblem Battery Voltage Too Low Prio Load 
Disconnected

        +-FmAlarmType=BFUIncompatibleWithPowerConfiguration

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId BFUIncompatibleWithPowerConfiguration
isStateful true
majorType 193
minorType 9175152
moClasses FieldReplaceableUnit
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem BFU Incompatible With Power Configuration

        +-FmAlarmType=BSCConnectionFailure

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId BSCConnectionFailure
isStateful true
majorType 193
minorType 9175139
moClasses AbisIp
probableCause m3100TransmissionError (10)
specificProblem BSC Connection Failure

        +-FmAlarmType=CalendarClockAllNTPServersUnavailable

Name Value
additionalText No NTP server configured, or no NTP service 
available
eventType processingErrorAlarm (4)
fmAlarmTypeId CalendarClockAllNTPServersUnavailable
isStateful true
majorType 193

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 6 sur 49

Name Value
minorType 9175058
moClasses SysM
probableCause x733ReceiveFailure (340)
specificProblem Calendar Clock All NTP Servers Unavailable

        +-FmAlarmType=CalendarClockMisaligned

Name Value
additionalText Clock was adjusted by more than 300 
seconds in order to keep up with the time 
references
eventType processingErrorAlarm (4)
fmAlarmTypeId CalendarClockMisaligned
isStateful true
majorType 193
minorType 9175060
moClasses SysM
probableCause x733UnderlyingResourceUnavailable (356)
specificProblem Calendar Clock Misaligned

        +-FmAlarmType=CalendarClockNTPServerUnavailable

Name Value
additionalText Configured NTP server is not used as basis for 
time of day clock
eventType communicationsAlarm (2)
fmAlarmTypeId CalendarClockNTPServerUnavailable
isStateful true
majorType 193
minorType 9175059
moClasses NTPServer
probableCause m3100Unavailable (14)
specificProblem Calendar Clock NTP Server Unavailable

        +-FmAlarmType=CalibrationFailure

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId CalibrationFailure
isStateful true
majorType 193
minorType 9175142
moClasses AntennaUnitGroup
probableCause x733EquipmentMalfunction (315)

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 7 sur 49

Name Value
specificProblem Calibration Failure

        +-FmAlarmType=CertMAutomaticEnrollmentFailed

Name Value
additionalText Automatic enrollment or renewal failed to 
execute due to local misconfiguration or 
remote enrollment service denial.
defaultSeverity WARNING
eventType processingErrorAlarm (4)
fmAlarmTypeId CertMAutomaticEnrollmentFailed
isStateful true
majorType 193
minorType 9175054
moClasses NodeCredential
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Certificate Management Automatic Enrollment 
Failed

        +-FmAlarmType=CertMCertificateNotAvailable

Name Value
additionalText The certificate provided by the alarming 
object is expired, revoked, or unavailable, 
which may result in the failure of a secure 
using this certificate.
defaultSeverity CRITICAL
eventType operationalViolation (8)
fmAlarmTypeId CertMCertificateNotAvailable
isStateful true
majorType 193
minorType 9175052
moClasses NodeCredential
probableCause x736OutOfService (414)
specificProblem Certificate Management a Valid Certificate is 
Not Available

        +-FmAlarmType=CertMCertificateToExpire

Name Value
additionalText The threshold before certificate expiration has 
been crossed, and the certificate should be 
renewed to prevent a secure service failure.
defaultSeverity WARNING
eventType qualityOfServiceAlarm (3)
fmAlarmTypeId CertMCertificateToExpire

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 8 sur 49

Name Value
isStateful true
majorType 193
minorType 9175053
moClasses NodeCredential
probableCause x733ThresholdCrossed (351)
specificProblem Certificate Management the Certificate is to 
Expire

        +-FmAlarmType=CircuitBreakerTripped

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId CircuitBreakerTripped
isStateful true
majorType 193
minorType 9175084
moClasses EFuse,FieldReplaceableUnit
probableCause m3100FuseFailure (110)
specificProblem Circuit Breaker Tripped

        +-FmAlarmType=ClimateInconsistentConfiguration

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId ClimateInconsistentConfiguration
isStateful true
majorType 193
minorType 9175154
moClasses EquipmentSupportFunction
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Climate Inconsistent Configuration

        +-FmAlarmType=ClockReferenceMissingForLongTime

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId ClockReferenceMissingForLongTime
isStateful true
majorType 193
minorType 9175063
moClasses RadioEquipmentClock

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 9 sur 49

Name Value
probableCause gsm1211ClockSynchronisationProblem (506)
specificProblem Clock Reference Missing For Long Time

        +-FmAlarmType=CloggedAirFilter

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId CloggedAirFilter
isStateful true
majorType 193
minorType 9175102
moClasses Cabinet
probableCause x733HeatingOrVentilationOrCoolingSystemProblem 
(321)
specificProblem Clogged Air Filter

        +-FmAlarmType=ConfigurationRequiresFeatureActivation

Name Value
additionalText
defaultSeverity MAJOR
eventType processingErrorAlarm (4)
fmAlarmTypeId ConfigurationRequiresFeatureActivation
isStateful true
majorType 193
minorType 9175042
moClasses EUtranCellFDD,EUtranCellTDD,NbIotCell,NodeBLocalCell,SectorEquipmentFunction,Trx
probableCause x733ConfigurationOrCustomizationError (307)
specificProblem Configuration Requires Feature Activation

        +-FmAlarmType=ConfigurationRequiresFeatureActivationServiceDegraded

Name Value
additionalText
defaultSeverity MINOR
eventType processingErrorAlarm (4)
fmAlarmTypeId ConfigurationRequiresFeatureActivationServiceDegraded
isStateful true
majorType 193
minorType 9175169
moClasses EUtranCellFDD,NodeBLocalCell
probableCause x733ConfigurationOrCustomizationError (307)
specificProblem Configuration Requires Feature Activation Service 
Degraded

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 10 sur 49

        +-FmAlarmType=CriticalTemperatureBatteryDisconnected

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId CriticalTemperatureBatteryDisconnected
isStateful true
majorType 193
minorType 9175096
moClasses BatteryBackup,FieldReplaceableUnit
probableCause x733EquipmentMalfunction (315)
specificProblem Critical Temperature Battery Disconnected

        +-FmAlarmType=CriticalTemperaturePerformanceDegraded

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId CriticalTemperaturePerformanceDegraded
isStateful true
majorType 193
minorType 9175078
moClasses FieldReplaceableUnit
probableCause x733TemperatureUnacceptable (350)
specificProblem Critical Temperature Performance Degraded

        +-FmAlarmType=CriticalTemperatureTakenOutofService

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId CriticalTemperatureTakenOutofService
isStateful true
majorType 193
minorType 9175079
moClasses EFuse,FieldReplaceableUnit,SupportUnit
probableCause x733TemperatureUnacceptable (350)
specificProblem Critical Temperature Taken Out of Service

        +-FmAlarmType=CrossConnectCableFault

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId CrossConnectCableFault

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 11 sur 49

Name Value
isStateful true
majorType 193
minorType 9175165
moClasses CcLink
probableCause x733EquipmentMalfunction (315)
specificProblem Cross Connect Cable Fault

        +-FmAlarmType=CurrentTooHigh

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId CurrentTooHigh
isStateful true
majorType 193
minorType 9175076
moClasses RfPort
probableCause x733EquipmentMalfunction (315)
specificProblem Current Too High

        +-FmAlarmType=DHCPLeaseExpiry

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId DHCPLeaseExpiry
isStateful true
majorType 193
minorType 9175193
moClasses InterfaceIPv4
probableCause x733CommunicationsProtocolError (305)
specificProblem DHCP Lease Expiry

        +-FmAlarmType=DHCPRequestedParameterMissing

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId DHCPRequestedParameterMissing
isStateful true
majorType 193
minorType 9175194
moClasses InterfaceIPv4
probableCause x733CommunicationsProtocolError (305)
specificProblem DHCP Requested Parameter Missing

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 12 sur 49

Name Value

        +-FmAlarmType=DHCPServerFault

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId DHCPServerFault
isStateful true
majorType 193
minorType 9175192
moClasses InterfaceIPv4
probableCause x733CommunicationsProtocolError (305)
specificProblem DHCP Server Fault

        +-FmAlarmType=E1orT1AlarmIndicationSignal

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId E1orT1AlarmIndicationSignal
isStateful true
majorType 193
minorType 9175124
moClasses E1T1Port
probableCause m3100AlarmIndicationSignal (1)
specificProblem E1 or T1 Alarm Indication Signal

        +-FmAlarmType=E1orT1LossofFrame

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId E1orT1LossofFrame
isStateful true
majorType 193
minorType 9175125
moClasses E1T1Port
probableCause m3100LossOfFrame (6)
specificProblem E1 or T1 Loss of Frame

        +-FmAlarmType=E1orT1LossofSignal

Name Value
additionalText

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 13 sur 49

Name Value
eventType communicationsAlarm (2)
fmAlarmTypeId E1orT1LossofSignal
isStateful true
majorType 193
minorType 9175126
moClasses E1T1Port
probableCause m3100LossOfSignal (8)
specificProblem E1 or T1 Loss of Signal

        +-FmAlarmType=E1orT1RemoteDefectIndication

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId E1orT1RemoteDefectIndication
isStateful true
majorType 193
minorType 9175127
moClasses E1T1Port
probableCause m3100LossOfFrame (6)
specificProblem E1 or T1 Remote Defect Indication

        +-FmAlarmType=E1orT1UnavailableTime

Name Value
additionalText
eventType qualityOfServiceAlarm (3)
fmAlarmTypeId E1orT1UnavailableTime
isStateful true
majorType 193
minorType 9175128
moClasses E1T1Port
probableCause x733ThresholdCrossed (351)
specificProblem E1 or T1 Unavailable Time

        +-FmAlarmType=ECBusUnreliableLink

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId ECBusUnreliableLink
isStateful true
majorType 193
minorType 9175180
moClasses EcBus

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 14 sur 49

Name Value
probableCause gsm1211LinkFailure (517)
specificProblem EC Bus Unreliable Link

        +-FmAlarmType=EFuseTripped

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId EFuseTripped
isStateful true
majorType 193
minorType 9175166
moClasses EFuse
probableCause m3100FuseFailure (110)
specificProblem EFuse Tripped

        +-FmAlarmType=EmergencyUnlockResetKeyRequired

Name Value
additionalText Emergency Unlock Reset Key required
eventType qualityOfServiceAlarm (3)
fmAlarmTypeId EmergencyUnlockResetKeyRequired
isStateful true
majorType 193
minorType 9175048
moClasses EmergencyUnlock
probableCause x733ResourceAtOrNearingCapacity (343)
specificProblem Emergency Unlock Reset Key Required

        +-FmAlarmType=EnclosureDoorOpen

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId EnclosureDoorOpen
isStateful true
majorType 193
minorType 9175085
moClasses Cabinet
probableCause m3100EnclosureDoorOpen (118)
specificProblem Enclosure Door Open

        +-FmAlarmType=EnclosureProductDataMismatch

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 15 sur 49

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId EnclosureProductDataMismatch
isStateful true
majorType 193
minorType 9175086
moClasses Cabinet
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Enclosure Product Data Mismatch

        +-FmAlarmType=EnclosureSmoke

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId EnclosureSmoke
isStateful true
majorType 193
minorType 9175087
moClasses Cabinet
probableCause m3100Smoke (132)
specificProblem Enclosure Smoke

        +-FmAlarmType=EnclosureSmokeDetectorFailure

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId EnclosureSmokeDetectorFailure
isStateful true
majorType 193
minorType 9175088
moClasses Cabinet
probableCause x733EquipmentMalfunction (315)
specificProblem Enclosure Smoke Detector Failure

        +-FmAlarmType=EthernetLinkFailure

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId EthernetLinkFailure
isStateful true
majorType 193

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 16 sur 49

Name Value
minorType 9175061
moClasses EthernetPort
probableCause m3100LossOfSignal (8)
specificProblem Ethernet Link Failure

        +-FmAlarmType=ExternalAlarm

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId ExternalAlarm
isStateful true
majorType 193
minorType 9175089
moClasses AlarmPort
probableCause gsm1211ExternalEquipmentFailure (550)
specificProblem External Alarm

        +-FmAlarmType=ExternalLinkFailure

Name Value
additionalText
defaultSeverity MINOR
eventType equipmentAlarm (5)
fmAlarmTypeId ExternalLinkFailure
isStateful true
majorType 193
minorType 9175110
moClasses ENodeBFunction
probableCause gsm1211LinkFailure (517)
specificProblem External Link Failure

        +-FmAlarmType=ExternalLinktoGNodeBFailure

Name Value
additionalText
defaultSeverity MINOR
eventType equipmentAlarm (5)
fmAlarmTypeId ExternalLinktoGNodeBFailure
isStateful true
majorType 193
minorType 9175203
moClasses ENodeBFunction
probableCause gsm1211LinkFailure (517)
specificProblem External Link to GNodeB Failure

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 17 sur 49

Name Value

        +-FmAlarmType=FallbackOperationStartingSoon

Name Value
additionalText The upgrade operation has not been 
confirmed yet. The ME will soon start fallback 
operation if the upgrade is not confirmed.
defaultSeverity WARNING
eventType other (1)
fmAlarmTypeId FallbackOperationStartingSoon
isStateful true
majorType 193
minorType 9175043
moClasses UpgradePackage
probableCause timeoutExpired (164)
specificProblem A Fallback Operation will soon be started

        +-FmAlarmType=FanDegraded

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId FanDegraded
isStateful true
majorType 193
minorType 9175148
moClasses FieldReplaceableUnit
probableCause x733EquipmentMalfunction (315)
specificProblem Fan Degraded

        +-FmAlarmType=FanDisconnected

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId FanDisconnected
isStateful true
majorType 193
minorType 9175143
moClasses FieldReplaceableUnit
probableCause x733EquipmentMalfunction (315)
specificProblem Fan Disconnected

        +-FmAlarmType=FanFailure

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 18 sur 49

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId FanFailure
isStateful true
majorType 193
minorType 9175090
moClasses FanGroup,FieldReplaceableUnit
probableCause x733EquipmentMalfunction (315)
specificProblem Fan Failure

        +-FmAlarmType=FanPowerSupplyFailure

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId FanPowerSupplyFailure
isStateful true
majorType 193
minorType 9175123
moClasses Cabinet,FanGroup
probableCause m3100PowerProblem (58)
specificProblem Fan Power Supply Failure

        +-FmAlarmType=FanSpeedContinuouslyHigh

Name Value
additionalText Fans have run at maximum speed for *value 
of attribute fanSpeedSupervision* hours.
eventType processingErrorAlarm (4)
fmAlarmTypeId FanSpeedContinuouslyHigh
isStateful true
majorType 193
minorType 9175199
moClasses Climate
probableCause x733SoftwareError (346)
specificProblem Fan Speed Continuously High

        +-FmAlarmType=FeatureResourceMissing

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId FeatureResourceMissing
isStateful true
majorType 193

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 19 sur 49

Name Value
minorType 9175077
moClasses AntennaNearUnit,RfPort,RiPort,SectorEquipmentFunction
probableCause x733ConfigurationOrCustomizationError (307)
specificProblem Feature Resource Missing

        +-FmAlarmType=FrequencySyncIOReferenceFailed

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId FrequencySyncIOReferenceFailed
isStateful true
majorType 193
minorType 9175062
moClasses RadioEquipmentClockReference
probableCause gsm1211ClockSynchronisationProblem (506)
specificProblem FrequencySyncIO Reference Failed

        +-FmAlarmType=GracePeriodActivated

Name Value
additionalText Grace Period Activated
eventType qualityOfServiceAlarm (3)
fmAlarmTypeId GracePeriodActivated
isStateful true
majorType 193
minorType 9175051
moClasses GracePeriod
probableCause x733ThresholdCrossed (351)
specificProblem Grace Period Activated

        +-FmAlarmType=HatchOpen

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId HatchOpen
isStateful true
majorType 193
minorType 9175187
moClasses FieldReplaceableUnit
probableCause m3100EnclosureDoorOpen (118)
specificProblem Hatch Open

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 20 sur 49

        +-FmAlarmType=HighOperatingTemperatureMainLoadDisconnected

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId HighOperatingTemperatureMainLoadDisconnected
isStateful true
majorType 193
minorType 9175091
moClasses PowerDistribution
probableCause x733EquipmentMalfunction (315)
specificProblem High Operating Temperature Main Load 
Disconnected

        +-FmAlarmType=HSPDSCHResourceAllocationFailure

Name Value
additionalText
defaultSeverity MINOR
eventType processingErrorAlarm (4)
fmAlarmTypeId HSPDSCHResourceAllocationFailure
isStateful true
majorType 193
minorType 9175212
moClasses NodeBLocalCellGroup
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem HS PDSCH Resource Allocation Failure

        +-FmAlarmType=HWFault

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId HWFault
isStateful true
majorType 193
minorType 9175071
moClasses AntennaNearUnit,FieldReplaceableUnit,PlugInModule,SupportUnit
probableCause x733EquipmentMalfunction (315)
specificProblem HW Fault

        +-FmAlarmType=IKEConfigurationPayloadFault

Name Value
additionalText

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 21 sur 49

Name Value
eventType communicationsAlarm (2)
fmAlarmTypeId IKEConfigurationPayloadFault
isStateful true
majorType 193
minorType 9175201
moClasses Ikev2Session
probableCause x733CommunicationsProtocolError (305)
specificProblem IKE Configuration Payload Fault

        +-FmAlarmType=IKEPeerCertificateFault

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId IKEPeerCertificateFault
isStateful true
majorType 193
minorType 9175137
moClasses Ikev2Session
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem IKE Peer Certificate Fault

        +-FmAlarmType=IKEPeerNotReachable

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId IKEPeerNotReachable
isStateful true
majorType 193
minorType 9175136
moClasses Ikev2Session
probableCause m3100Unavailable (14)
specificProblem IKE Peer Not Reachable

        +-FmAlarmType=IncompatibleHWConfiguration

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId IncompatibleHWConfiguration
isStateful true
majorType 193
minorType 9175164

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 22 sur 49

Name Value
moClasses FieldReplaceableUnit,SfpModule
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Incompatible HW Configuration

        +-FmAlarmType=InconsistentConfiguration

Name Value
additionalText
defaultSeverity MAJOR
eventType processingErrorAlarm (4)
fmAlarmTypeId InconsistentConfiguration
isStateful true
majorType 193
minorType 9175068
moClasses AlarmPort,AntennaNearUnit,AntennaUnit,Cabinet,EUtranCellFDD,EUtranCellTDD,EcPort,Eq
probableCause x733ConfigurationOrCustomizationError (307)
specificProblem Inconsistent Configuration

        +-FmAlarmType=IndoorRAPCableInsertionLoss

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId IndoorRAPCableInsertionLoss
isStateful true
majorType 193
minorType 9175170
moClasses RdiPort
probableCause x733EquipmentMalfunction (315)
specificProblem Indoor RAP Cable Insertion Loss

        +-FmAlarmType=IndoorRAPCommunicationProblem

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId IndoorRAPCommunicationProblem
isStateful true
majorType 193
minorType 9175171
moClasses RdiPort
probableCause gsm1211LinkFailure (517)
specificProblem Indoor RAP Communication Problem

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 23 sur 49

        +-FmAlarmType=IndoorRAPConfigurationNotSupported

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId IndoorRAPConfigurationNotSupported
isStateful true
majorType 193
minorType 9175172
moClasses FieldReplaceableUnit
probableCause x733EquipmentMalfunction (315)
specificProblem Indoor RAP Configuration Not Supported

        +-FmAlarmType=IndoorRAPDesensitizationNoiseFigureOutofRange

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId IndoorRAPDesensitizationNoiseFigureOutofRange
isStateful true
majorType 193
minorType 9175185
moClasses SectorEquipmentFunction
probableCause x733ConfigurationOrCustomizationError (307)
specificProblem Indoor RAP Desensitization Noise Figure Out of 
Range

        +-FmAlarmType=IndoorRAPHWFault

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId IndoorRAPHWFault
isStateful true
majorType 193
minorType 9175173
moClasses FieldReplaceableUnit
probableCause x733EquipmentMalfunction (315)
specificProblem Indoor RAP HW Fault

        +-FmAlarmType=IndoorRAPIncompatibleSoftware

Name Value
additionalText
defaultSeverity MINOR
eventType processingErrorAlarm (4)

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 24 sur 49

Name Value
fmAlarmTypeId IndoorRAPIncompatibleSoftware
isStateful true
majorType 193
minorType 9175214
moClasses FieldReplaceableUnit
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Indoor RAP Incompatible Software

        +-FmAlarmType=IndoorRAPNoConnection

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId IndoorRAPNoConnection
isStateful true
majorType 193
minorType 9175174
moClasses FieldReplaceableUnit,RdiPort
probableCause x733EquipmentMalfunction (315)
specificProblem Indoor RAP No Connection

        +-FmAlarmType=IndoorRAPPowerOverEthernetFault

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId IndoorRAPPowerOverEthernetFault
isStateful true
majorType 193
minorType 9175175
moClasses FieldReplaceableUnit
probableCause x733EquipmentMalfunction (315)
specificProblem Indoor RAP Power Over Ethernet Fault

        +-FmAlarmType=IndoorRAPSWDownloadFailure

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId IndoorRAPSWDownloadFailure
isStateful true
majorType 193
minorType 9175176
moClasses FieldReplaceableUnit

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 25 sur 49

Name Value
probableCause m3100SoftwareDownloadFailure (156)
specificProblem Indoor RAP SW Download Failure

        +-FmAlarmType=IndoorRAPSWError

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId IndoorRAPSWError
isStateful true
majorType 193
minorType 9175177
moClasses FieldReplaceableUnit
probableCause x733SoftwareError (346)
specificProblem Indoor RAP SW Error

        +-FmAlarmType=IndoorRAPTemperatureExceptional

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId IndoorRAPTemperatureExceptional
isStateful true
majorType 193
minorType 9175178
moClasses FieldReplaceableUnit
probableCause x733TemperatureUnacceptable (350)
specificProblem Indoor RAP Temperature Exceptional

        +-FmAlarmType=InsufficientBatteryCharging

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId InsufficientBatteryCharging
isStateful true
majorType 193
minorType 9175092
moClasses BatteryBackup
probableCause gsm1211BatteryChargingFault (505)
specificProblem Insufficient Battery Charging

        +-FmAlarmType=InterNodeCarrierAggregationServiceUnavailable

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 26 sur 49

Name Value
additionalText
defaultSeverity MINOR
eventType communicationsAlarm (2)
fmAlarmTypeId InterNodeCarrierAggregationServiceUnavailable
isStateful true
majorType 193
minorType 9175198
moClasses ExternalENodeBFunction
probableCause m3100Unavailable (14)
specificProblem Inter Node Carrier Aggregation Service 
Unavailable

        +-FmAlarmType=InterNodeFeatureIncompatibility

Name Value
additionalText
defaultSeverity MINOR
eventType processingErrorAlarm (4)
fmAlarmTypeId InterNodeFeatureIncompatibility
isStateful true
majorType 193
minorType 9175186
moClasses ExternalENodeBFunction
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Inter Node Feature Incompatibility

        +-FmAlarmType=KeyFileFault

Name Value
additionalText Key file fault in Managed Element
eventType processingErrorAlarm (4)
fmAlarmTypeId KeyFileFault
isStateful true
majorType 193
minorType 9175046
moClasses Lm
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem License Key File Fault

        +-FmAlarmType=LACPFailure

Name Value
additionalText

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 27 sur 49

Name Value
eventType communicationsAlarm (2)
fmAlarmTypeId LACPFailure
isStateful true
majorType 193
minorType 9175209
moClasses LagPort
probableCause x733CommunicationsProtocolError (305)
specificProblem LACP Failure

        +-FmAlarmType=LargeNumberOfCounters

Name Value
additionalText
eventType qualityOfServiceAlarm (3)
fmAlarmTypeId LargeNumberOfCounters
isStateful true
majorType 193
minorType 9175056
moClasses Pm
probableCause x733PerformanceDegraded (334)
specificProblem Large Number of Counters

        +-FmAlarmType=LicensedCapacityExceeded

Name Value
additionalText
defaultSeverity MINOR
eventType processingErrorAlarm (4)
fmAlarmTypeId LicensedCapacityExceeded
isStateful true
majorType 193
minorType 9175163
moClasses ExtTrx,NodeBLocalCell,Trx
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Licensed Capacity Exceeded

        +-FmAlarmType=LicenseKeyCloseToExpiration

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId LicenseKeyCloseToExpiration
isStateful true
majorType 193

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 28 sur 49

Name Value
minorType 9175204
moClasses Lm
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem License Key Close to Expiration

        +-FmAlarmType=LicenseKeyNotAvailable

Name Value
additionalText Key missing for feature or capacity
eventType processingErrorAlarm (4)
fmAlarmTypeId LicenseKeyNotAvailable
isStateful true
majorType 193
minorType 9175047
moClasses FeatureState
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem License Key Not Available

        +-FmAlarmType=LinearizationDisturbancePerformanceDegraded

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId LinearizationDisturbancePerformanceDegraded
isStateful true
majorType 193
minorType 9175155
moClasses FieldReplaceableUnit
probableCause gsm1211TransceiverProblem (529)
specificProblem Linearization Disturbance Performance 
Degraded

        +-FmAlarmType=LinkDegraded

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId LinkDegraded
isStateful true
majorType 193
minorType 9175197
moClasses RiLink
probableCause x733EquipmentMalfunction (315)

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 29 sur 49

Name Value
specificProblem Link Degraded

        +-FmAlarmType=LinkFailure

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId LinkFailure
isStateful true
majorType 193
minorType 9175144
moClasses RiLink
probableCause x733EquipmentMalfunction (315)
specificProblem Link Failure

        +-FmAlarmType=LinkStability

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId LinkStability
isStateful true
majorType 193
minorType 9175145
moClasses RiLink
probableCause gsm1211LinkFailure (517)
specificProblem Link Stability

        +-FmAlarmType=LogHasReachedFullCapacity

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId LogHasReachedFullCapacity
isStateful true
majorType 193
minorType 9175057
moClasses Log
probableCause x733FileError (317)
specificProblem Log Has Reached Full Capacity

        +-FmAlarmType=LossofMains

Name Value
additionalText

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 30 sur 49

Name Value
eventType environmentalAlarm (6)
fmAlarmTypeId LossofMains
isStateful true
majorType 193
minorType 9175093
moClasses FieldReplaceableUnit,PowerSupply,SupportUnit
probableCause m3100CommercialPowerFailure (106)
specificProblem Loss of Mains

        +-FmAlarmType=LowBatteryCapacity

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId LowBatteryCapacity
isStateful true
majorType 193
minorType 9175094
moClasses BatteryBackup
probableCause m3100BatteryFailure (105)
specificProblem Low Battery Capacity

        +-FmAlarmType=MissingBFUConfigurationandConnection

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId MissingBFUConfigurationandConnection
isStateful true
majorType 193
minorType 9175121
moClasses BatteryBackup
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Missing BFU Configuration and Connection

        +-FmAlarmType=MissingSXU

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId MissingSXU
isStateful true
majorType 193
minorType 9175101

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 31 sur 49

Name Value
moClasses FieldReplaceableUnit
probableCause m3100ReplaceableUnitMissing (62)
specificProblem Missing SXU

        +-FmAlarmType=NoConnection

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId NoConnection
isStateful true
majorType 193
minorType 9175073
moClasses AntennaNearUnit,Cabinet,EcBus,EquipmentSupportFunction,ExternalNode,FanGroup,Field
probableCause x733EquipmentMalfunction (315)
specificProblem No Connection

        +-FmAlarmType=NodeGroupSyncConfigurationFault

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId NodeGroupSyncConfigurationFault
isStateful true
majorType 193
minorType 9175150
moClasses NodeGroupSyncMember
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Node Group Sync Configuration Fault

        +-FmAlarmType=NodeGroupSyncLossofAllSoCC

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId NodeGroupSyncLossofAllSoCC
isStateful true
majorType 193
minorType 9175149
moClasses NodeGroupSyncMember
probableCause gsm1211ClockSynchronisationProblem (506)
specificProblem Node Group Sync Loss of All SoCC

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 32 sur 49

        +-FmAlarmType=NotPossibletoStartAILG

Name Value
additionalText
defaultSeverity MINOR
eventType processingErrorAlarm (4)
fmAlarmTypeId NotPossibletoStartAILG
isStateful true
majorType 193
minorType 9175111
moClasses EUtranCellFDD,EUtranCellTDD
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Not Possible to Start AILG

        +-FmAlarmType=NumberofHWEntitiesMismatch

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId NumberofHWEntitiesMismatch
isStateful true
majorType 193
minorType 9175095
moClasses Cabinet,EcBus
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Number of HW Entities Mismatch

        +-FmAlarmType=OutputCurrentTooHigh

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId OutputCurrentTooHigh
isStateful true
majorType 193
minorType 9175160
moClasses SupportUnit
probableCause gsm1211ExternalEquipmentFailure (550)
specificProblem Output Current Too High

        +-FmAlarmType=PartlyDisconnected

Name Value
additionalText

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 33 sur 49

Name Value
eventType equipmentAlarm (5)
fmAlarmTypeId PartlyDisconnected
isStateful true
majorType 193
minorType 9175159
moClasses SupportUnit
probableCause x733EquipmentMalfunction (315)
specificProblem Partly Disconnected

        +-FmAlarmType=PLMNServiceDegraded

Name Value
additionalText
defaultSeverity MINOR
eventType communicationsAlarm (2)
fmAlarmTypeId PLMNServiceDegraded
isStateful true
majorType 193
minorType 9175140
moClasses EUtranCellFDD,EUtranCellTDD,NbIotCell
probableCause m3100Unavailable (14)
specificProblem PLMN Service Degraded

        +-FmAlarmType=PLMNServiceUnavailable

Name Value
additionalText
defaultSeverity MAJOR
eventType communicationsAlarm (2)
fmAlarmTypeId PLMNServiceUnavailable
isStateful true
majorType 193
minorType 9175141
moClasses EUtranCellFDD,EUtranCellTDD,NbIotCell
probableCause m3100Unavailable (14)
specificProblem PLMN Service Unavailable

        +-FmAlarmType=PowerInconsistentConfiguration

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId PowerInconsistentConfiguration
isStateful true
majorType 193

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 34 sur 49

Name Value
minorType 9175153
moClasses EquipmentSupportFunction
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Power Inconsistent Configuration

        +-FmAlarmType=PowerLoss

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId PowerLoss
isStateful true
majorType 193
minorType 9175147
moClasses FieldReplaceableUnit
probableCause gsm1211PowerSupplyFailure (522)
specificProblem Power Loss

        +-FmAlarmType=ProblemstoScheduleSIMessages

Name Value
additionalText
defaultSeverity MINOR
eventType qualityOfServiceAlarm (3)
fmAlarmTypeId ProblemstoScheduleSIMessages
isStateful true
majorType 193
minorType 9175112
moClasses EUtranCellFDD,EUtranCellTDD,NbIotCell
probableCause x733Congestion (308)
specificProblem Problems to Schedule SI Messages

        +-FmAlarmType=ResourceActivationTimeout

Name Value
additionalText
defaultSeverity MAJOR
eventType processingErrorAlarm (4)
fmAlarmTypeId ResourceActivationTimeout
isStateful true
majorType 193
minorType 9175118
moClasses EUtranCellFDD,EUtranCellTDD,NbIotCell,NodeBLocalCell,SectorEquipmentFunction,Trx
probableCause gsm1211TimeoutExpired (546)

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 35 sur 49

Name Value
specificProblem Resource Activation Timeout

        +-FmAlarmType=ResourceActivationTimeoutServiceDegraded

Name Value
additionalText
defaultSeverity MINOR
eventType processingErrorAlarm (4)
fmAlarmTypeId ResourceActivationTimeoutServiceDegraded
isStateful true
majorType 193
minorType 9175183
moClasses EUtranCellFDD,EUtranCellTDD,ExtTrx,NbIotCell,NodeBLocalCell,Trx
probableCause gsm1211TimeoutExpired (546)
specificProblem Resource Activation Timeout Service Degraded

        +-FmAlarmType=ResourceAllocationFailure

Name Value
additionalText
defaultSeverity MAJOR
eventType processingErrorAlarm (4)
fmAlarmTypeId ResourceAllocationFailure
isStateful true
majorType 193
minorType 9175113
moClasses EUtranCellFDD,EUtranCellTDD,ExtTrx,MbmsService,NbIotCell,NodeBLocalCell,NodeBSecto
probableCause x733ConfigurationOrCustomizationError (307)
specificProblem Resource Allocation Failure

        +-FmAlarmType=ResourceAllocationFailureServiceDegraded

Name Value
additionalText
defaultSeverity MINOR
eventType processingErrorAlarm (4)
fmAlarmTypeId ResourceAllocationFailureServiceDegraded
isStateful true
majorType 193
minorType 9175167
moClasses EUtranCellFDD,EUtranCellTDD,NbIotCell,NodeBLocalCell,NodeBSectorCarrier,SectorCarrie
probableCause x733ConfigurationOrCustomizationError (307)
specificProblem Resource Allocation Failure Service Degraded

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 36 sur 49

        +-FmAlarmType=ResourceConfigurationFailure

Name Value
additionalText
defaultSeverity MAJOR
eventType processingErrorAlarm (4)
fmAlarmTypeId ResourceConfigurationFailure
isStateful true
majorType 193
minorType 9175075
moClasses EUtranCellFDD,EUtranCellTDD,ExtTrx,NbIotCell,NodeBLocalCell,SectorEquipmentFunction
probableCause x733ConfigurationOrCustomizationError (307)
specificProblem Resource Configuration Failure

        +-FmAlarmType=ResourceConfigurationFailureServiceDegraded

Name Value
additionalText
defaultSeverity MINOR
eventType processingErrorAlarm (4)
fmAlarmTypeId ResourceConfigurationFailureServiceDegraded
isStateful true
majorType 193
minorType 9175182
moClasses EUtranCellFDD,EUtranCellTDD,ExtTrx,NbIotCell,NodeBLocalCell,Trx
probableCause x733ConfigurationOrCustomizationError (307)
specificProblem Resource Configuration Failure Service Degraded

        +-FmAlarmType=ResourceNotInstalled

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId ResourceNotInstalled
isStateful true
majorType 193
minorType 9175179
moClasses SectorEquipmentFunction
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem Resource Not Installed

        +-FmAlarmType=RETFailure

Name Value
additionalText

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 37 sur 49

Name Value
eventType equipmentAlarm (5)
fmAlarmTypeId RETFailure
isStateful true
majorType 193
minorType 9175120
moClasses RetSubUnit
probableCause x733EquipmentMalfunction (315)
specificProblem RET Failure

        +-FmAlarmType=RETNotCalibrated

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId RETNotCalibrated
isStateful true
majorType 193
minorType 9175074
moClasses RetSubUnit
probableCause x733EquipmentMalfunction (315)
specificProblem RET Not Calibrated

        +-FmAlarmType=RFReflectedPowerHigh

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId RFReflectedPowerHigh
isStateful true
majorType 193
minorType 9175119
moClasses RfPort
probableCause x733EquipmentMalfunction (315)
specificProblem RF Reflected Power High

        +-FmAlarmType=RNCConnectionFailure

Name Value
additionalText
defaultSeverity MAJOR
eventType communicationsAlarm (2)
fmAlarmTypeId RNCConnectionFailure
isStateful true
majorType 193
minorType 9175041

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 38 sur 49

Name Value
moClasses NbapCommon
probableCause x733CommunicationsSubsystemFailure (306)
specificProblem RNC Connection Failure

        +-FmAlarmType=RollbackEscalationStarted

Name Value
additionalText Software error occured. Rollback to previous 
backup starts in one hour unless operator 
logs into ME.
eventType processingErrorAlarm (4)
fmAlarmTypeId RollbackEscalationStarted
isStateful true
majorType 193
minorType 9175066
moClasses SysM
probableCause x733SoftwareProgramError (348)
specificProblem Rollback Escalation Started

        +-FmAlarmType=RunningonBatterySupply

Name Value
additionalText
eventType environmentalAlarm (6)
fmAlarmTypeId RunningonBatterySupply
isStateful true
majorType 193
minorType 9175097
moClasses BatteryBackup
probableCause m3100BatteryDischarging (104)
specificProblem Running on Battery Supply

        +-FmAlarmType=RXBranchImbalanceFault

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId RXBranchImbalanceFault
isStateful true
majorType 193
minorType 9175200
moClasses AntennaUnitGroup
probableCause x733EquipmentMalfunction (315)
specificProblem RX Branch Imbalance Fault

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 39 sur 49

        +-FmAlarmType=RXDiversityLost

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId RXDiversityLost
isStateful true
majorType 193
minorType 9175181
moClasses AntennaUnitGroup
probableCause x733EquipmentMalfunction (315)
specificProblem RX Diversity Lost

        +-FmAlarmType=ScheduledBackupFailed

Name Value
additionalText The scheduled backup creation failed or an event could not be scheduled
defaultSeverity WARNING
eventType processingErrorAlarm (4)
fmAlarmTypeId ScheduledBackupFailed
isStateful true
majorType 193
minorType 9175044
moClasses BrmBackupScheduler,BrmCalendarBasedPerodicEvent,BrmPerodicEvent,BrmSingleEvent
probableCause x733SoftwareProgramError (348)
specificProblem Scheduled Backup Failed

        +-FmAlarmType=SCTPEndpointInconsistentConfiguration

Name Value
additionalText
defaultSeverity MAJOR
eventType processingErrorAlarm (4)
fmAlarmTypeId SCTPEndpointInconsistentConfiguration
isStateful true
majorType 193
minorType 9175189
moClasses ENodeBFunction
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem SCTP Endpoint Inconsistent Configuration

        +-FmAlarmType=ServiceDegraded

Name Value
additionalText

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 40 sur 49

Name Value
defaultSeverity MINOR
eventType qualityOfServiceAlarm (3)
fmAlarmTypeId ServiceDegraded
isStateful true
majorType 193
minorType 9175114
moClasses EUtranCellFDD,EUtranCellRelation,EUtranCellTDD,NbIotCell
probableCause x733PerformanceDegraded (334)
specificProblem Service Degraded

        +-FmAlarmType=ServiceUnavailable

Name Value
additionalText
defaultSeverity MAJOR
eventType processingErrorAlarm (4)
fmAlarmTypeId ServiceUnavailable
isStateful true
majorType 193
minorType 9175115
moClasses EUtranCellFDD,EUtranCellTDD,NbIotCell
probableCause x733UnderlyingResourceUnavailable (356)
specificProblem Service Unavailable

        +-FmAlarmType=SFPHWFault

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId SFPHWFault
isStateful true
majorType 193
minorType 9175196
moClasses SfpModule
probableCause x733EquipmentMalfunction (315)
specificProblem SFP HW Fault

        +-FmAlarmType=SFPNotPresent

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId SFPNotPresent
isStateful true
majorType 193

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 41 sur 49

Name Value
minorType 9175156
moClasses SfpModule
probableCause m3100ReplaceableUnitMissing (62)
specificProblem SFP Not Present

        +-FmAlarmType=SFPPowerFailure

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId SFPPowerFailure
isStateful true
majorType 193
minorType 9175157
moClasses SfpModule
probableCause m3100PowerProblem (58)
specificProblem SFP Power Failure

        +-FmAlarmType=SFPProductNumberMismatch

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId SFPProductNumberMismatch
isStateful true
majorType 193
minorType 9175213
moClasses SfpModule
probableCause m3100ReplaceableUnitTypeMismatch (63)
specificProblem SFP Product Number Mismatch

        +-FmAlarmType=SFPStabilityProblem

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId SFPStabilityProblem
isStateful true
majorType 193
minorType 9175146
moClasses SfpModule
probableCause x733EquipmentMalfunction (315)
specificProblem SFP Stability Problem

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 42 sur 49

        +-FmAlarmType=SoftwareManagementLostConnectiontoFileServer

Name Value
additionalText Connectivity to the upgrade package file server 
is lost. Software download is not possible
defaultSeverity WARNING
eventType processingErrorAlarm (4)
fmAlarmTypeId SoftwareManagementLostConnectiontoFileServer
isStateful true
majorType 193
minorType 9175195
moClasses UpgradePackage
probableCause x733ConfigurationOrCustomizationError (307)
specificProblem Software Management Lost Connection to File 
Server

        +-FmAlarmType=STNtoBSCLinkDown

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId STNtoBSCLinkDown
isStateful true
majorType 193
minorType 9175129
moClasses TgTransport
probableCause gsm1211ConnectionEstablishmentError (566)
specificProblem STN to BSC Link Down

        +-FmAlarmType=SuspectedSleepingCell

Name Value
additionalText
defaultSeverity MAJOR
eventType qualityOfServiceAlarm (3)
fmAlarmTypeId SuspectedSleepingCell
isStateful true
majorType 193
minorType 9175117
moClasses EUtranCellFDD,EUtranCellTDD,NodeBLocalCell
probableCause x733ThresholdCrossed (351)
specificProblem Suspected Sleeping Cell

        +-FmAlarmType=SWDownloadFailure

Name Value

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 43 sur 49

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId SWDownloadFailure
isStateful true
majorType 193
minorType 9175069
moClasses AntennaNearUnit,FieldReplaceableUnit
probableCause m3100SoftwareDownloadFailure (156)
specificProblem SW Download Failure

        +-FmAlarmType=SWError

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId SWError
isStateful true
majorType 193
minorType 9175070
moClasses AntennaNearUnit,FieldReplaceableUnit
probableCause x733SoftwareError (346)
specificProblem SW Error

        +-FmAlarmType=SyncEReferenceConfigurationNotSupported

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId SyncEReferenceConfigurationNotSupported
isStateful true
majorType 193
minorType 9175106
moClasses RadioEquipmentClockReference
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem SyncE Reference Configuration Not Supported

        +-FmAlarmType=SyncEReferenceFailed

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId SyncEReferenceFailed
isStateful true
majorType 193

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 44 sur 49

Name Value
minorType 9175064
moClasses RadioEquipmentClockReference
probableCause gsm1211ClockSynchronisationProblem (506)
specificProblem SyncE Reference Failed

        +-FmAlarmType=SyncFrequencyPDVProblem

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId SyncFrequencyPDVProblem
isStateful true
majorType 193
minorType 9175107
moClasses RadioEquipmentClockReference
probableCause m3100Unavailable (14)
specificProblem Sync Frequency PDV Problem

        +-FmAlarmType=SyncFrequencyReferenceNotReliable

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId SyncFrequencyReferenceNotReliable
isStateful true
majorType 193
minorType 9175131
moClasses RadioEquipmentClockReference
probableCause m3100Unavailable (14)
specificProblem Sync Frequency Reference Not Reliable

        +-FmAlarmType=SyncFrequencyServerReachabilityFault

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId SyncFrequencyServerReachabilityFault
isStateful true
majorType 193
minorType 9175108
moClasses RadioEquipmentClockReference
probableCause m3100Unavailable (14)
specificProblem Sync Frequency Server Reachability Fault

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 45 sur 49

        +-FmAlarmType=SyncPTPTimeAvailabilityFault

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId SyncPTPTimeAvailabilityFault
isStateful true
majorType 193
minorType 9175133
moClasses RadioEquipmentClockReference
probableCause m3100Unavailable (14)
specificProblem Sync PTP Time Availability Fault

        +-FmAlarmType=SyncPTPTimePDVProblem

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId SyncPTPTimePDVProblem
isStateful true
majorType 193
minorType 9175132
moClasses RadioEquipmentClockReference
probableCause m3100Unavailable (14)
specificProblem Sync PTP Time PDV Problem

        +-FmAlarmType=SyncPTPTimeReachabilityFault

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId SyncPTPTimeReachabilityFault
isStateful true
majorType 193
minorType 9175135
moClasses RadioEquipmentClockReference
probableCause m3100Unavailable (14)
specificProblem Sync PTP Time Reachability Fault

        +-FmAlarmType=SyncPTPTimeReliabilityFault

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId SyncPTPTimeReliabilityFault

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 46 sur 49

Name Value
isStateful true
majorType 193
minorType 9175134
moClasses RadioEquipmentClockReference
probableCause m3100Unavailable (14)
specificProblem Sync PTP Time Reliability Fault

        +-FmAlarmType=SyncReferenceQualityLevelTooLow

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId SyncReferenceQualityLevelTooLow
isStateful true
majorType 193
minorType 9175168
moClasses RadioEquipmentClockReference
probableCause m3100SynchronisationSourceMismatch (64)
specificProblem Sync Reference Quality Level Too Low

        +-FmAlarmType=SystemGeneralProblem

Name Value
additionalText This is a non-recoverable SW error, a HWfault 
not detectable by HW test, or a configuration 
fault.
eventType processingErrorAlarm (4)
fmAlarmTypeId SystemGeneralProblem
isStateful true
majorType 193
minorType 9175067
moClasses SystemFunctions
probableCause x733SoftwareProgramError (348)
specificProblem System General Problem

        +-FmAlarmType=SystemOvervoltage

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId SystemOvervoltage
isStateful true
majorType 193
minorType 9175098
moClasses PowerSupply

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 47 sur 49

Name Value
probableCause m3100PowerProblem (58)
specificProblem System Overvoltage

        +-FmAlarmType=SystemUndervoltage

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId SystemUndervoltage
isStateful true
majorType 193
minorType 9175099
moClasses PowerSupply
probableCause m3100PowerProblem (58)
specificProblem System Undervoltage

        +-FmAlarmType=TemperatureSensorFailure

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId TemperatureSensorFailure
isStateful true
majorType 193
minorType 9175100
moClasses BatteryBackup,FieldReplaceableUnit
probableCause x733EquipmentMalfunction (315)
specificProblem Temperature Sensor Failure

        +-FmAlarmType=TimeSyncIOReferenceFailed

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId TimeSyncIOReferenceFailed
isStateful true
majorType 193
minorType 9175065
moClasses RadioEquipmentClockReference
probableCause gsm1211ClockSynchronisationProblem (506)
specificProblem TimeSyncIO Reference Failed

        +-FmAlarmType=TMFConfigurationFailure

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 48 sur 49

Name Value
additionalText
eventType processingErrorAlarm (4)
fmAlarmTypeId TMFConfigurationFailure
isStateful true
majorType 193
minorType 9175138
moClasses AntennaNearUnit
probableCause x733ConfigurationOrCustomizationError 
(307)
specificProblem TMF Configuration Failure

        +-FmAlarmType=TransportSessionDown

Name Value
additionalText
eventType communicationsAlarm (2)
fmAlarmTypeId TransportSessionDown
isStateful true
majorType 193
minorType 9175130
moClasses TgTransport
probableCause gsm1211ConnectionEstablishmentError (566)
specificProblem Transport Session Down

        +-FmAlarmType=UnreliableResource

Name Value
additionalText
defaultSeverity MINOR
eventType processingErrorAlarm (4)
fmAlarmTypeId UnreliableResource
isStateful true
majorType 193
minorType 9175116
moClasses EUtranCellFDD,EUtranCellTDD,NbIotCell,NodeBLocalCell,Trx
probableCause x733ConfigurationOrCustomizationError (307)
specificProblem Unreliable Resource

        +-FmAlarmType=VSWROverThreshold

Name Value
additionalText
eventType equipmentAlarm (5)
fmAlarmTypeId VSWROverThreshold
isStateful true

http://localhost:9032/alexserv?AC=LINK&ID=7055&FN=2418_15554-LZA7016014... 02/02/2023
mib Alarm_CXP2020013_1 Page 49 sur 49

Name Value
majorType 193
minorType 9175040
moClasses RfPort
probableCause x733EquipmentMalfunction (315)
specificProblem VSWR Over Threshold

mib Alarm_CXP2020013_1