MYPIA Weight Indicator
MYPIA Weight Indicator
Ordering code Operating setting press SET Key until to enter the menu
LM Series Weighing Controller MODEL Functions ↓
Instruction Manual LM LM Series
1 Parameter setting: Alarm 1 setting, range -1999- 9999
Thanks for selecting MYPIN product! 4 48H * 48W *80L
A press and hold SET key until to enter Alarm 1 output controll
Before operating this instrument, please carefully read this manual and SIZE 8 48H * 96W *80L
setting menu. ↓ SET H:High output weight > AL1,AL1 active,
fully understand its contents. If any problems, please contact our sales or 9 96H * 96W *80L
distributors whom you buy from. This manual is subject to change without B Press << /Rst key once, LED flashing weight < AL1-HY1,AL1 inactive
Blank : 220V / 110V AC L: Low output weight < AL1 ,AL1 active
prior notice. Power Press << /Rst to shift LED if need ↓ SET
E 18-30V or 24VDC weighr >AL1+HY1,AL1 inactive
C press Up or Down key to modify data,
Application blank:none
D press SET key to confirm data. Alarm 2 setting, range -1999- 9999
Transmit DC 0-10V
1 Weight measurement and control V E Press SET key to read other parameters, Alarm 2 output controll
output I DC 4-20mA and repeat B,C,D steps to modify data if need
↓ SET H:High output weight > AL2,AL2 active,
*Mixed Batching control R AL3:alarm, no transmit F .press and hold SET key until to quit menu weight < AL2-HY1,AL2 inactive
2 Direct Load :1-4 PCS loadcells, 24 Bits A / D N N: none L: Low output weight < AL2 ,AL2 active
2.Weight Adjustment: ↓SET weight > AL2+HY1,AL2 inactive
3 Digital Input: Start / Stop and Clear Tare AL1 R Relay: AC250V / 3A
Alarm 3 setting(Hidden when no AL3)
4 Output::4-20mA / 0-10V , Relay / SSR / Logic output S SSR : 12 / 24V / 30mA
Alarm A when empty (no load),press DOWN key until
5 Data Peak value holding function for choice. N N: none
↓SET Alarm3 output controll (hidden when no AL3)
‘Oy’ flashing. release DOWN key ; PV LED
6 Communication : RS485 RS232,RJ45(LAN) AL2 R RELAY: AC250V/3A
displays about 0 H:High output weight > AL3,AL3 active,
S SSR,12/24V/30mA weight < AL3-HY1,AL3 inactive
MODBUS-RTU protocol. B Follow step A,placing the weight of this
L: Low output weight < AL3 ,AL3 active
Blank: none calibration, press UP key until SV LED flashing. ↓SET weight > AL3+HY1,AL3 inactive
Panel(for reference) 2 RS232 release UP key.refer parameter setting step
Communication to set SV LED data,SV LED data = the weight
Hysteresis value setting for all alarms.
4 RS485
g Range: ±50.0
AL1 5 LAN RJ45 of this calibration (Equal USP parameter), ↓ SET
PV E.g,the calibrate weight is 50Kg, communication ID address ,Range :000-250,
AL2
T D 5V / 80mA
Setting SV data=50.00, the unit is Kg,
AL3
Kg Excition source B 24V / 3 0mA Baud rate: 9.6K Bit or :19.2Kbit
Setting SV data=0.050, the unit is Ton
E Other:order C Refer Page 2 to lock adjust operation If need ↓ SET
SV SET Reserved,( Tare weight
<<
<<
>>
Alarm: 2-Relay High or Low output, E.g when no load,PV display range: -0.2--+0.2, E.g weight display range 0.0 -200.0 for output
4-20mA (or 0-10V), set trL=0.0
Specifications input: load cells
set PF2=0.3 > |PV|=0.2, PV will display 0.0,
↓ SET
but if PV > PF2, E.g PV value =0.31> 0.2, Transmit output high value:
Power 220V/110V AC 90-260V AC/DC or 24V AC/DC PV LED will normal display 0.31. E.g weright display range 0.0 -200.0 for output
Consumpsion ≤5VA Mounting and Sizes 4-20mA (or 0-10V), set trH=200.0
Accuracy 0.1%F.S±2digit
↓SET
Sampling speed ≤16times/sec 1 LM4 W48 X H48 X L80mm mounting W45 X H45mm weight unit: : g : Kg : Ton
Relay: Normal Open AC 250V 3A or DC 30V 5A 2 LM8 W48 X H96 X L80mm mounting W45 X H92mm
output
Resistive load ;SSR:12V/24V,MAX30mA
3 LM9 W96 X H96 X L80mm mounting W92 X H92mm ↓ SET Parameter lock, range:0-255
Input 1-4 PCS Loadcells Others:mA / V (special order) 4 LM10 W160X H80 X L70mm
LCK=010,is for read only.
Tramsmit output DC 4-20mA / 0-10V etc. mounting: W152X H76mm
LCK=000 Read and Write.
Communication RS232 / RS485 RJ45 MODBUS RTU protocol
press SET Key until to quit the menu or return AL1
Connections
(If any changed, refer the label on the meter).
load cells
Calibration Lock / Unlock LM MODBUS USER INSTRUCTIONS
RST/TARE
press UP and Down key until to enter menu
AL2 AL1 220V AC
L N Baud Rate 1 The instrument RS485/RS232 MODBUS-RTU data format
→
com
-
+
→
9.6K Bit/S OR 19.2K Bit/S
+ 10
11
2
12
→ 1
Start bit Data bit Stop bit Parity Baud rate
→3
4
5
6
7
9
8 factory:9.6K Bit/S
→
110V AC
EXC
↓ Prt=No,Unlock calibration,
SG
SET
LM8-RRD 1 8 1 None 9.6k or 19.2kBitS
Prt=YES,lock calibration,Calibration
load cells
opretion not allowed (refer PAGE 1 2 The format of the data reading and writing is same as standard Modbus protocol.
↓ SET weight adjustment )
RST/TARE AL2 AL1
Definition as follows:
220V AC
PV LED zero value setting. Request:(eg.TX: 01 03 00 62 00 02 65 D5)
→
L N
-
+
→
com
If |PV| < PF2,the PV disiplay is 0
+ 10
11
2
12
→ 1
→3
4
↓SET
5
6
7
9
8
110V AC
EXC
SG
RS232 RS485
Reserved weight=Ct*USP-PVF
ADD COM PV Counts CRC
19
→1 8
17
17
→1 8
↓
→
LM8-RR4D/RR2D SET
GND RXD TXD B- A+ Response: (eg.RX: 01 03 04 6D 96 49 F3 71 66)
Calibration password for factory
load cells 01 03 04 6D96 49F3 7166
RST/TARE AL2 AL1 220V AC press UP and Down key until to quit menu ADD COM Count PV CRC
L N
→
-
+
com
+ 10
11
2
12
→ 1
→3
4
5
6
7
9
8
110V AC
EXC
SG
(49F3H=18931 6D96H=28054)When Max bit is “1”,means negative, E.g PV=ED96 49F3 = - 6D96.49F3H= -28054.2888
→1 8
17
→
LM8-IRRD/VRRD - + 3, Can read OR write 1 parameter only every time,when writing ,Please convert the demical data to hexadecimal data,
OUTPUT 4-20mA OR 0-10V
.For example,100.5,INT 100=0064H,0.5=0.8000H,therefore 100.5=0064.8000H,100.5 data=00 64 80 00
Complete products contains 4 Clear Tare: Parameter PVF(Address 10H), TX: 01 06 00 10 00 00 88 0F, 01:ID number,,06:COM ,ingnore writing data
★1 copy of user manual, 5, Commands: 03H: read holding registers parameters 06H: write single holding register parameter value
★1 inspection QC label,
★2 installing brachets,
10H: write multi holding registers parameters value
We are responsible for the overal repairment for the failure of
manufactorying quality within 12 months since the date of purchase. 5, Communication parameters:LM Weighing meter reading and writing parameter
More information:PLS Down load from : www.mypinchina.com Parameters data address count data address count
(HEX) (w o r d s )
functions Parameters (w o r d s ) functions
IP/wechat: 86-18689341985, Email:[email protected] (HEX)
PV 62H 2 weight value,read only Add 0FH 1 ID address,0-255,R/W
Main Products AL1 00H 2 AL1Value, R/W USP 14H 2 the weight of calibration, R/W
Counter & length meter AM1 03H 1 AL1 control, 0:L,1:H, R/W dp 17H 1 PV decimal point, R/W
Time relay
Temperature controller AL2 04H 2 AL2Value, R/W SFt 18H 1 software filtering Value,R/W
Panel meter
Frequency/Tacho/Line-speed meter AM2 07H 1 AL2 control, 0:L,1:H, R/W TRL 1CH 2 Transmit low value, R/W
Proximity sensor Photo-electrical sensor
Ampere & Voltage Power meter AL3 08H 2 AL3Value, R/W TRH 20H 2 Transmit high value, R/W
Transmitter
Universal Sensor indicator
AM3 0BH 1 AL3 control, 0:L,1:H, R/W Unt 23H 1 weight unit, 0: g, 1: Kg, 2: T, R/W
Power adjustor
HY1 0CH 2 AL1 AL2 AL3 control hysteresis, R/W LCK 24H 1 Parameter lock, R/W