RoCorr MFL-A
RoCorr MFL-A
RoCorr MFL-A
THE SOLUTION
ROSEN’s Magnetic Flux Leakage Technology is the right
choice to reliably and effectively detect and characterize
internal and external metal loss features.
Our inspection tools embody robust and multi-faceted
technology with a proven record of sensitivity and accuracy,
ensuring the best possible results in every performance
category.
Our well-structured, certified data evaluation process
enables ROSEN’s data analysts to provide the required high-
quality assessment on time.
Our reporting software ensures easy data visualization and
facilitates the broad use of inspection results.
SERVICE OPTIONS
All aspects from the inspection request to the final report are
covered with the flexibility to choose from various service
options.
• Cleaning – operational and pre inspection
• Speed Control – inspection at high flow rates
• XYZ – route mapping and strain assessment
• Multi-Diameter – pipelines with varying diameter
• Combo – multiple inspection technologies in one run
• BiDi – single entry pipelines
• Offshore – long distance and high pressure
• Post-ILI – data alignment and combined evaluation
• Integrity Assessments – RBI, FFP, CGA
• NIMA – versatile asset integrity software suite
www.rosen-group.com
ROCORR MFL-A SERVICE
IN-LINE HIGH-RESOLUTION METAL LOSS DETECTION AND SIZING
TECHNICAL SPECIFICATIONS
Standard Operating Specifications Metal Loss Feature Classification
Tool sizes available 3" - 56" All reported metal loss features are classified according to
Pipeline product Gas or liquids the dimensions shown in the following Pipeline Operators’
Product temperature range 0 °C - 65 °C (32 °F - 150 °F) Forum (POF) specification graph.
Maximum operating pressure 15 MPa (2,175 psi)
25 MPa (3,625 psi) optional A = wall thickness or 10 mm (0.39”), whichever value is greater
Width/A
Circumferential grooving
Product flow range* Up to 12 m/s (26.8 mph)
Minimum pipeline bend radius 1.5D 8
Circumferential slotting
Wall thickness range 4 - 32 mm (0.15" - 1.26")
7
Maximum operating time 400 hours
Maximum inspection length 800 km (500 miles) 6
* Fitted with optional speed control system (gas lines only)
Note: Please contact ROSEN for conditions outside of these specifications. 5 General
Performance Specifications
General Axial Circumf. Circumf.
metal loss Pitting Grooving Grooving Slotting1)
Depth at POD = 90 % 0.1t 0.1t 0.1t 0.1t 0.15t
Depth sizing accuracy at 80 % certainty ±0.1 t ±0.1 t ±0.15 t ±0.1 t ±0.1 t
Width sizing accuracy at 80 % certainty ±15 mm (0.59") ±12 mm (0.47") ±12 mm (0.47") ±12 mm (0.47") ±15 mm (0.59”)
Length sizing accuracy at 80 % certainty ±15 mm (0.59") ±10 mm (0.39") ±10 mm (0.39") ±10 mm (0.39") ±10 mm (0.39”)
Abbreviations: POD = Probability of Detection; t = wall thickness
www.rosen-group.com