Clivet Applied Product Solution For Data Center - 20220120

1) Clivet has over 30 years of experience providing sustainable and efficient cooling solutions for data centers and ensuring human well-being. 2) Clivet offers specially designed low pressure ratio centrifugal chillers for large data centers that have high efficiency and intelligent energy management. 3) Clivet also provides free cooling product solutions using air or water that are suitable for small to medium sized data centers to lower energy costs.

Uploaded by

remigius yudhi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
160 views10 pages

Clivet Applied Product Solution For Data Center - 20220120

1) Clivet has over 30 years of experience providing sustainable and efficient cooling solutions for data centers and ensuring human well-being. 2) Clivet offers specially designed low pressure ratio centrifugal chillers for large data centers that have high efficiency and intelligent energy management. 3) Clivet also provides free cooling product solutions using air or water that are suitable for small to medium sized data centers to lower energy costs.

Uploaded by

remigius yudhi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Valid from: January 2022

FOR OVER 30 YEARS WE HAVE BEEN


OFFERING SOLUTIONS TO ENSURE
SUSTAINABLE COMFORT
AND THE WELL-BEING OF PEOPLE
AND THE ENVIRONMENT

www.clivet.com
Applied Product Solution
For Data Center

CLIVET SPA
Via Camp Lonc 25, Z.I. Villapaiera
32032 Feltre (BL) - Italy
Tel. +39 0439 3131 - Fax +39 0439 313300
[email protected]
Demand of Data Center Benefits of Clivet Applied Products

HIGH EFFICIENCY CHILLER


Reliability
● Uninterruptible running of equipment without failure
● Rapid restart after power supply is available
● Standby equipment and emergency cold
source are considered for the system
Low pressure ratio centrifugal chiller Free cooling product solutions (air cooled screw chiller)
Applicable to: Mega and large data centers Applicable to: Small and medium-sized data centers

Energy saving 01 High efficiency

● High sensible heat, low latent heat 02 VFD


Medium/high
● Adopt the unit with high water outlet temperature 03 Low harmonic current
temperature chiller
● Rational use of natural cold source and 04 Quick start
peak-valley price
05 Wide operating range

SPECIALLY DESIGNED LOW PRESSURE RATIO CENTRIFUGAL CHILLER


Intelligent energy ● The design pressure ratio is relatively low, in order to get a good specific speed, a lower design speed is adopted, so that
higher aerodynamic efficiency can be obtained in this range.
● System control logic is different from ordinary
air conditioning system ● IGV, impeller, diffuser, volute and other aerodynamic components are with new aerodynamic design, which can better
● High energy consumption, high requirement adapt to the change of gas inlet volume flow, so that the gas flows into the impeller at an appropriate angle, reduces the
for intelligentization impact loss of the impeller.

Process requirements
● Electronic components are sensitive to temperature,
humidity, and cleanliness, so these factors need to
be under strict control

● Considering the overall use of users, the working conditions with the largest proportion of use are in the highest efficiency
range to ensure good energy saving effect.
Airflow organization ● Two-stage compression, surge margin is larger. Low-pressure head can prevent surge by preventing the speed from being
● Large air flow, small enthalpy difference too low. Under the condition of high pressure head, the speed of the impeller is actively increased and adjusted with guide
vane to achieve stable operation and expand the operating range of compressor. Adopt new surge current identification
● CFD simulation to prevent too cold/hot locally
technology, real-time detection of current waveform, accurate identification of surge risk, to achieve equipment protection.

01 02
Benefits of Clivet Applied Products

QUICK START TWO CONFIGURATIONS


● Remember the startup running state before power failure, and start the unit according to the original state after power Direct free cooling
failure, so as to meet the requirements of rapid changes in the heat of communication equipment, especially in the case of Circulating water in the project system is with glycol.
power failure and restart. Featuring quick start, Clivet centrifugal chiller can restart in as little as 32s after power is restored. Free cooling fin + electric three-way valve, achieve free cooling at
EXV
low ambient temperature.
● It takes only 180s to return to 100% capacity while other comparable chillers need at least 300s to reach full load. Ideal for Direct heat exchange, high heat exchange efficiency.
temperature sensitive applications such as data centers, manufacturing processes and hospitals where need the unit to Overall project circulating water is anti-freeze liquid, strong
restart quickly after a power failure. anti-freezing ability.
Client requires consideration of glycol system design.
Time to reach full load (s)

Other air cooled


screw chiller
Indirect free cooling
AirBoost air cooled Circulating water in the project system is conventional water.
screw chiller Free cooling fin, plate heat exchanger and glycol circulating
pump to form a closed system. EXV Glycol inside
0 50 100 150 200 250 300 350 the unit
Equipped with plate heat exchanger, transfer free cooling energy
to the whole project.
FREE COOLING SOLUTIONS
The terminal system and the water pump do not need to
For data center applications where cooling capacity required is stable in any outdoor condition and it is not effected by outdoor consider the performance attenuation and water resistance
temperature, using solutions that exploit low outdoor temperatures for supplying cooling capacity for free is strongly increase caused by antifreeze liquid.
suggested. Tw o - s t a g e h e a t e xc h a n g e c a n re d u c e h e a t e xc h a n g e
When the outdoor temperature is lower than the temperature of the system's return water, the free cooling system recovers requirements of the compressor.
cold from the external environment and reduces the operation of the compressors until they stop completely. No need for special water system design.
No-Glycol inside
Clivet solution is: Built-in free cooling heat exchanger, less space; Free cooling and compressor refrigeration sharing a set of fans, the project system
energy saving and easy maintenance.
THREE OPERATING MODES

Summer Middle season Winter

Air
flow
Refrigerant system

Glycol soluton

Free cooling is off. Free cooling is on. Free cooling is on.


Compression cycle is on. Compression cycle is on. Compression cycle is off.

03 04
Benefits of Clivet Applied Products

In-Array Series Underfloor Installation

APPLICATION SCENARIOS The air conditioner is under the floor, even if there is water leakage, it does not affect the server and the equipment room will
never be affected by water.
IDC data center, sealed heat/cold channel.

FEATURES
In-Array series VS In-Row series

Installed under the electrostatic floor Installed above the electrostatic floor

p
Energy Saving Installed at the bottom of the server panel, the floor can provide
protection and isolation
Installed side by side with the server panel, without protection
Water leak can cause fatal damage to the server
The water leaks out from under the floor, so there is no water danger
All DC inverter In-Array series precision air conditioner pPUE is as low as 1.008. It saves 71.7% more electricity than In-Row
series.

pPUE
Factory Fabrication
1.04
1.035
1.035
Product modularization. Installation of water pipes, connectors and other engineering installation transferred to factory
1.03
1.025 prefabrication, the installation efficiency increased by 90%+
1.02
1.015
1.01 1.008 Factory fabrication Assembled on site
1.005
1
In-Array series In-Row series

In-Array series pPUE=1.008, In-Row series pPUE=1.035


Transportation

Space Saving
The air conditioner is placed under the electrostatic floor, which saves equipment room space. APPLICATION
The loading rate of the equipment room is increased by 18.2% compared with In-Row series, and the economic income is
In-Array series + High efficiency centrifugal chiller + Free Cooling + Clivet-BMS, realizing the equipment room PUE≤1.25.
increased by 18%+.

Server panel
In-Row series

IT equipment panel PUE≤1.25

High efficiency In-Array series High efficiency centrifugal chiller + Free Cooling
precision air conditioner
Electrostatic floor Electrostatic floor

In-Array series Main control box

Extension box
Clivet-BMS
(Support customized development)

05 06
Benefits of Clivet Applied Products

IDC DATA CENTER AIR CONDITIONING SOLUTION


In-Room Series
APPLICATION SCENARIOS
Precision air
conditioner
Cloud computing, transportation, energy and other
medium and large communication equipment
room and IDC data center.

IT equipment panel

IT equipment panel

IT equipment panel

IT equipment panel
Chilled
water

Underfloor air supply

PRODUCT INTRODUCTION MODULAR DESIGN

Frame type structure, modular design. Flexible combination and easy to expand cooling capacity.
1 Standard with G4 filter, reduce the pollution of dust particles

2 "V/A" type evaporator, high efficiency heat exchange


3
3 Accurately monitor the state of filter and fan to ensure the
1
healthy operation of the unit

4 Modular splicing, easy to disassemble


4

module

module

module
Master

Slave

Slave
2

Master module and Slave module (before assembly) Unit after assembly
(Utility model patent, patent number: CN201520281128.X)
5

5 PTC heater, small heating resistance, high heat transfer EASY INSTALLATION
efficiency, safe and reliable Key components are pre-integrated from the factory to reduce the amount of on-site installation work. Standardized design,
easy to transport.
6 New rotary electric control box, front design, easy 8
7
maintenance
Elevator
7 High efficiency humidifier, large humidification to meet Corridor corner

the humidity requirements


6
8 High efficiency EC fan, sunken design Disassembled into a single
Disassembled into a single
module, easy to pass
module, easy to
the corner of the corridor
transport by elevator

07 08
Benefits of Clivet Applied Products

Cold storage: conventional chiller + dual-working condition centrifugal chiller + cold storage tank
In-Row Series
Cold storage applies to areas with peak and valley electricity prices. At night with valley electricity price, the dual-working
condition centrifugal chiller is used for cooling; in the daytime with peak electricity price, the stored cold capacity is discharged
APPLICATION SCENARIOS for cooling in various working conditions.
IDC data center, medium and large switching equipment
room, local high heat room, high heat density room and
modular data
Cold water
center. pipe network

Chiller
Chilled
PRODUCT INTRODUCTION water
pump

In-Row series precision air conditioner is a row level chilled water temperature control product. It is a
terminal air supply unit installed in the equipment room. It usually forms a complete refrigeration 18°C
Chilled
12°C 18°C
water
system together with water chiller, water pump and chilled water pipe, etc. It adopts EC fan, usually Cold water pump Cold water Cold water
pipe network pipe network pipe network
installed in the row of equipment panel, close to the heat source, providing heat dissipation solu
tions for medium and high density data centers, helping to build the next generation of green data Chilled Data center
water
centers. pump

STABLE AND RELIABLE Chilled water pump


Plate heat exchanger

12°C 7°C
Fans are backup to each other Professional device selection and design
Can be maintained online, no interruption to cooling in the process
of fan replacement Dual-working Glycol pump Ice storage coil
condition unit
Intelligent control Dual power supplies (optional)
Balance running time of each unit, extending service life When the power is cut off in one circuit, it can automatically
switch to the other circuit

ENERGY SAVING ADVANTAGES

High efficiency component Dry coil design Efficient matching Dual-working condition unit and cold storage system can be used as emergency cold sources for a more reliable system.
DC EC fan No dehumidification and Match with high efficiency Clivet chiller Tailored for peak and valley electricity prices to save costs.
Proportional integral water valve flow control humidification power consumption Clivet-BMS AI linkage control
The adoption of cold storage unit can reduce the unit capacity and the initial investment in chiller equipment.
0 power consumption wet film humidification
(optional)
APPLICATION

EASY ACCESS Medium and large data centers

7-inch touch screen Expert-level troubleshooting Full front or back maintenance


Display device running status, user-friendly

09 10
Benefits of Clivet Applied Products

Condensation heat recovery: heat pump centrifugal chiller/screw chiller + precision air conditioner Clivet-BMS

The HVAC systems of IDCs are complex. With the help of the Clivet-BMS, the systems can achieve efficient, stable, and energy
saving operations.
Hot water Heating, domestic hot water
pipe network
Hot water
pump
40°C 50°C 40°C

Management layer
Cloud Energy Air Air side
Mobile
Clivet-BMS DTU energy AI large screen display collection detection billing
O&M
efficiency system system system
Hot water Hot water
pipe network pipe
network
Hot water boiler

Cooling
tower Cold/heat
complementary

Control layer
Multi-agent Multi-agent
Cooling energy-saving energy-saving
water 32°C 37°C
control panel control panel AI core controller
pump (strong and weak (M2 power
current integrated) distribution panel) Clivet cloud gateway

Chilled water pump Data center


18°C 12°C 18°C

Cold water
pipe network
Chiller

Equipment layer
Control switch, sensor, professional valve
(proportional-integral valve, electric valve, dynamic balance adjusting valve, smart valve)
Cold water pipe network
On-site self-control device

ADVANTAGES
Cold/Heat Transmission and Cooling
distribution MAHU FCU FAPU Lighting
source equipment
A large amount of condensation heat is generated during the long-term operation of data center. With the condensation and equipment

heat recovery system, the cooling requirements in summer, heating requirements in winter, and domestic hot water supply all Electromechanical equipment under control Ammeter Air quality Networked
Heat meter detector thermostat
year round in administrative and office areas of the data center can be met. It is energy efficient, improves the comprehensive
energy efficiency of the data center and brings about more economic benefits.

APPLICATION ADVANTAGES

Medium and large data centers The intelligent control of equipment room devices and air side air-conditioning devices is achieved. Based on the running
trend, the system can implement self diagnosis, adjust the operation status, maintain efficient operation of the entire
air-conditioning system, reduce the data center PUE, and save management and operation costs.

11 12
Clivet Application Solutions

Chillers Precision Air Conditioners Clivet-BMS


Inverter direct-drive centrifugal chiller In-Array Series Clivet Cloud Energy Efficiency Management System Strong and Weak Current Integrated Panel

The platform aims to provide visualized, integrated and Intelligent control of chiller plant system and wind
economical energy management services with large data system, cooperate with software application
processing capabilities and provide users with energy
information storage, display, calculation and analysis in the
form of cloud-hosted ser vices, thus maximizing
energy-saving potential and reducing energy consumption.

350-1,700RT 6.5kW

MagBoost magnetic centrifugal chiller In-Room Series

Chiller Plant Control Software Standard Chiller Plant Control Panel


Strong and weak current control of chiller plant and
terminals, cooperate with software application
170-1,250RT 30kW/65kW

AirBoost air cooled screw chiller In-Row Series

80-450RT 30-180kW

13 14
Reference Projects

China Mobile (Suzhou) Cloud Computing Center/R&D Center SPECIAL DESIGN:

1. Auto switch to power supply by generator when the mains is cut, auto start of unit within three minutes.
PERFORMANCE PARAMETERS
2. Low water temperature and low flow operation of cooling water; cooling water pipeline bypass control.
● Cooling capacity: 1800/2000RT
3. Hot gas bypass design to guarantee stable water temperature under low load; load of chiller can be as low as 10%.
● Working conditions: 19/14°C (chilled water), 32/37°C (cooling water)

● Special requirement: high temperature chiller 4. Energy saving design; cooling for equipment room by cooling tower plate heat exchanger in seasons with low temperature.

5. Online cleaning device to prevent condenser scaling.

UNIT SELECTION: 6. Large capacity cold storage tank that can ensure cooling supply for four hours in emergencies.
High voltage centrifugal chiller 1800RT 2

High voltage centrifugal chiller 2000RT 7

15 16
Reference Projects

Shenzhen Pengcheng Cloud Brain II Data Center


PERFORMANCE PARAMETERS

1. Project overview
Pengcheng Cloud Brain directly connects to the innovation base platform of the national new-generation AI development strat-
egy and major scientific engineering, and focuses on areas such as new-generation AI basic research and major scientific and
theoretic issues for information processing breakthrough. The construction of Pengcheng Cloud Brain also represents the
important development of diversified computing methods, and is of great reference value to the further application and prac- China Mobile (2020-2021) China Mobile (2018-2019) China Telecom Guangdong
tice of heterogeneous computing.
2. Design overview
The equipment room building of Pengcheng Data Center has three floors. Floor 1 is for distribution substations, battery rooms,
and operator equipment rooms. Floor 2 and Floor 3 are for data equipment rooms, control rooms, test equipment rooms, and
offices. Steel structure is adopted. The cold source module and chilled/cooling hydraulic module are configured on Floor 1.
3. System overview
The total cooling capacity of the data center is about 4428kW. Three 700RT centrifugal chillers in 2+1 mode are adopted. The
cooling capacity of each chiller is 2461kW (700RT).
Each refrigeration station has three cold source hydraulic modules, one chilled hydraulic module, and one cooling hydraulic
module. Floor 2 is for the liquid cooled cooling system, including one liquid cooled module. Two cold storage tanks are set out-
Shenzhen Sunway Huawei data center
doors. Shenyang Railway Bureau
Communication in Yantai

China Mobile (Harbin) Data center of Guangzhou Huangcun data center of


data center Baiyun International Airport China Unicom's Beijing branch

Financial center of the Industrial China Telecom's Beijing Control center of


and Commercial Bank of China's Science Park Shanghai Metro
Chengdu branch office