CR60K5-PFV

HCFC, R-22, 60Hz, 1- Phase, 208/230 V


Air Conditioning
Production Status: Available for sale to all U.S. customers. Please check with your local Emerson Climate
Technologies Representative for international availability.

Performance Mechanical
Number of Cylinders: 2 Displ(in^3/Rev): 5.82
Evap(°F)/Cond(°F) 45 / 130 45 / 100
Bore Size(in): 1.96 Displ(ft^3/hr): 706.92
RG(°F)/Liq(°F) 65.0 / 115.0 65.0 / 85.0 Stroke(in): 0.96
Capacity 58500 75000
(Btu/hr)
Power (Watts): 5750 4660 Overall Length (in): 11.38 Mounting Length (in): 7.50
Current (Amps): 25.90 20.90 Overall Width (in): 9.38 Mounting Width (in): 7.50
EER (Btu/Wh): 10.10 16.10 Overall Height (in): 15.88 Mounting Height (in): 16.25 *
Mass Flow (lbs/hr): 855 965
Suction Size (in): 7/8 Stub
Sound Power (dBA): 79 Avg 84 Max Discharge Size (in): 1/2 Stub
Vibration (mils(peak- 5.0 Avg 6.0 Max Oil Recharge (oz): 66
Initial Oil Charge (oz): 70
Record Date: 2012-02-13 Net Weight (lbs): 87
Internal Free Volume (in^3):
Horse Power:
*Overall compressor height on Copeland Brand Product's specified
mounting grommets.

Electrical
LRA-High*: 135.0 MCC (Amps): 43.0 UL File No:
LRA-Half Winding: RPM: 3500 UL File Date:
LRA Low*: Max Operating Current:
RLA(=MCC/1.4;use for contactor selection): 30.7
RLA(=MCC/1.56;use for breaker & wire size 27.6

*Low and High refer to the low and high nominal voltage ranges for which the motor is approved.

Type Part No Low MFD High MFD Volts User Description


Start Capacitor 014-0006-13 189.0 227.0 330 HIGH TORQUE
Run Capacitor 014-0064-15 45.0 0.0 440
Start Capacitor 014-0064-15 45.0 0.0 440 LOW TORQUE

Alternate Applications
Refrigerant Freq (Hz) Phase Voltage Application
R-502 CFC 50 1 200

R-502 CFC 60 1 208/230

R-22 HCFC 50 1 200 Air Conditioning