External Bypass - Verification Procedure - Customer Space - Allot Confluence Server
External Bypass - Verification Procedure - Customer Space - Allot Confluence Server
Verification Procedure
Added by Ratinesh Kumar, last edited by Dan Shalem on Jun 09, 2013
Verification Procedure
1. Ensure the NE serial interface (Bypass) is connected to the serial interface (Primary) on the Bypass unit
using the Allot provided DB9 cable.
2. The LED for Mode on the NE will be green when the NE is connected to the Bypass Unit and is active. The
LED will be off (no light) when either the Bypass Unit is not connected to the NE or the NE is in bypass
mode.
3. Connect the Internal interface on the Bypass to the Internal Interface (labeled ‘To NetEnforcer’)
4. Connect the External interface on the Bypass to the Internal Interface (labeled ‘To NetEnforcer’)
5. Connect the Internal interface on the Bypass (NOT labeled ‘To NetEnforcer’. On the left) to the Internal network
router/switch
6. Connect the External interface on the Bypass (NOT labeled ‘To NetEnforcer’. On the left) to the External/Upstream
network router/switch
https://kb.allot.com/display/CUS/External+Bypass+-+Verification+Procedure 1/4
17/06/13 External Bypass - Verification Procedure - Customer Space - Allot Confluence Server
7. On the NX GUI right click on the NE and select ‘Configuration’. In the NE configuration select the ‘Networking’ tab.
Ensure the ‘Enable Bypass Unit’ is checked.
8. Log into the NE via SSH and verify the NE is active with command: ‘go config view network’. System status
should be ‘active’
https://kb.allot.com/display/CUS/External+Bypass+-+Verification+Procedure 2/4
17/06/13 External Bypass - Verification Procedure - Customer Space - Allot Confluence Server
11. To do a loop test to ‘Eliminate the Bypass Unit’ disconnect the Bypass unit from the NE. Connect the Internal
Interface (labeled ‘To NetEnforcer’) on the Bypass Unit to the External Interface (labeled ‘To NetEnforcer’). Ensure the
Serial cable is still connected. Traffic should pass through.
12. To do a loop test to ‘Eliminate the NE’ disconnect the Bypass unit from the NE. Connect the Internal Interface on
the NE to Internal network router/switch and the External Interface to the External/Upstream network router/switch.
Ensure the Bypass is disabled (Uncheck the ‘Enable Bypass in 7 above or enter commend ‘go config network –
https://kb.allot.com/display/CUS/External+Bypass+-+Verification+Procedure 3/4
17/06/13 External Bypass - Verification Procedure - Customer Space - Allot Confluence Server
13. Also verify that the correct type of cables are being used as well as the Duplex and Speed settings are correct.
Change the Duplex and Speed settings of the NE interfaces to Auto to avoid mismatches.
14. Also verify that the NIC 'Action on failure' is set to the desired action.
https://kb.allot.com/display/CUS/External+Bypass+-+Verification+Procedure 4/4