Datasheet: Fanless Multi-Range D.C. Power Supply
Datasheet: Fanless Multi-Range D.C. Power Supply
Datasheet: Fanless Multi-Range D.C. Power Supply
Analog
Control LAN
FEATURES
Constant Power Output for Fivefold Multi-Range(V&I) Operation
Natural Convection Cooling Design (Fanless Structure)
Preset Memory Function
Output ON/OFF Delay Function
CV, CC Priority Mode
Adjustable Slew Rate For Voltage and Current
Bleeder Circuit Control
Protection : OVP, OCP, AC FAIL and OTP
Support Front Panel and Rear Panel Output
Built-in USB and RS-232/485 Interface Optional LAN+GPIB
Web Server Monitoring and Control
External Analog Control and Monitor Function
Remote Sensing Function
The RSFR-100 series, a small and high-performance programmable D.C. power supply, adopts natural convection design to
dissipate heat. The fanless structure allows users to focus on their experiments and tests in a quiet environment. Fanless power
supply will not suck in dust and foreign objects, therefore, RSFR-100 series has a longer life cycle compared with that of power
supplies with fan.
The RSFR-100 series is a power supply with a five-fold rated power that allows users to self-define voltage and current under rated
power conditions so as to satisfy them with wider voltage and current operational ranges. RSFR-100 series, with rated 100 W,
provides two models: RSFR-100L- maximum output voltage of 50 V (at 2 A) or maximum output current of 10 A (at 10 V);
RSFR- 100M- maximum output voltage of 250 V (at 0.4 A) or maximum output current of 2 A (at 50 V).
The RSFR-100 series provides front and rear panel output terminals. The front panel output terminal helps users shorten test lead
replacement time while conducting adjustment on front panel's function keys. The rear panel output terminal facilitates an easy
wiring operation for rackmount assembly. 3U height, 70 mm width and 2.5 KG in weight have greatly elevated RSFR-100 series
portability. Furthermore, the multi-drop mode allows users to control up to 31 RSFR-100 series without using switch/Hub that
help users save the equipment cost.
The LAN interface for RSFR-100 is Ethernet port. RSFR-100 also has a built-in web server and intuitive user interface. Users, via
general browsers including Internet Explorer, Mozilla Firefox or Android cellular phones, can monitor RSFR-100's test and
measurement anywhere. Users not only can remotely monitor RSFR-100 via internet, but also remotely observe and adjust their
operating RSFR-100s in the lab from your home. The outputs of RSFR-100 series can be monitored including OVP, OCP, UVL;
and the system information can be checked such as unit's serial number, firmware edition and internet setting. Users can
remotely adjust RSFR-100 settings, including output voltage/current, the slew rate for voltage/current, Bleeder circuit control,
OCP, delayed time for output voltage and Buzzer settings.
The RSFR-100 series provides special functionalities to meet test requirements for different load's characteristics. The CC priority
mode can be applied for DUTs with diode characteristics to prevent DUT from being damaged by inrush current. A slow rise time
for voltage can also protect DUT from inrush current, especially for tests on capacitive load. When power is off or load is
disconnected, the activation of Bleeder circuit control will allow the bleeder resistor to consume filter capacitor's electricity.
Without the bleed resistor, power supply's filter capacitor may still have electricity that is a potential hazard. For automatic testing
equipment systems, the bleeder resistor allows RSFR-100 series to rapidly discharge to prepare itself for the next operation.
RSFR-100L RSFR-100M
Model RSFR-100L RSFR-100M
Output Channel 1 1
Output Voltage 0~ 50 V 0~ 250 V
Output Current 0~ 10 A 0~ 2 A
Rated Power 100 W 100 W
SPECIFICATIONS
Model RSFR-100L RSFR-100M
OUTPUT RATING Rated Output Voltage 50 V 250 V
Rated Output Current 10 A 2A
Rated Output Power 100 W 100 W
REGULATION(CV) Load Regulation (*2) 10 mV 33 mV
Line Regulation (*1) 3 mV 5 mV
REGULATION(CC) Load Regulation (*9) 10 mA 3.2 mA
Line Regulation (*1) 8 mA 1.2 mA
RIPPLE & NOISE (*3) Vp-p (*4) 50 mV 150 mV
Vr.m.s.(*5) 4 mV 15 mV
A r.m.s. 10 mA 2 mA
PROGRAMMING ACCURACY Voltage 0.1% of setting + 40 mV 200 mV
Current 0.2% of setting + 20 mA 2 mA
MEASUREMENT ACCURACY Voltage 0.1% of reading + 40 mV 200 mV
Current 0.2% of reading + 20 mA 2 mA
RESPONSE TIME Rise Time (*6) Rated load 50 ms 200 ms
Fall Time (*7) Rated load 100 ms 300 ms
No load 500 ms 3000 ms
Transient Response Time (*8) 1.5 ms 2 ms
PROGRAMMING RESOLUTION Voltage 2 mV 10 mV
Current 1 mA 0.1 mA
MEASUREMENT RESOLUTION Voltage 2 mV 10 mV
Current 1 mA 0.1 mA
PROTECTION FUNCTION Over Voltage Protection (OVP) Setting range 5~55 V 5~275 V
Over Current Protection (OCP) Setting range 1~11 A 0.2~2.2 A
Under Voltage Limit (UVL) Setting range 0~52.5 V 0~262.5 V
Over Temperature Protection (OTP) Operation Turn the output off. Turn the output off.
Low AC Input Protection (AC-Fail) Operation Turn the output off. Turn the output off.
Power Limit (Power Limit) Operation Turn the output off. Turn the output off.
FRONT PANEL DISPLAY Voltage 0.1% of reading + 40 mV 200 mV
ACCURACY, 4 DIGITS Current 0.2% of reading + 20 mA 2 mA
ENVIRONMENT CONDITION Operaing Temperature 0°C to 40°C
Storage Temperature -20°C to 70°C
Operating Humidity 20% to 80% RH; No condensation
Storage Humidity 20% to 85% RH; No condensation
READBACK TEMP. COEFFICIENT Voltage 100ppm/℃
(After A 30 Minute Warm-up) Current 200ppm/℃
OTHER Analog Control Yes
Interface USB, RS-232/RS-485; Factory option: LAN/GPIB
AC Input 85~265VAC, 47~63Hz, single pahse
DIMENSIONS & WEIGHT 70(W)x124(H)x300(D)mm; Approx.2.5 kg
*1: At 85 ~ 132Vac or 170 ~ 265Vac, constant load.
*2: From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote Sense. RSFR-100 Series Fanless Multi-Range D.C. Power Supply
*3: Measure with JEITA RC-9131B (1:1) probe RSF R- 100 - G L - G T L - 258
*4: Measurement frequency bandwidth is 10Hz to 20MHz. Model: Cable Options:
*5: Measurement frequency bandwidth is 5Hz to 1MHz. L : 0~50V/10A/100W GTL-258 : A GPIB cable including 25 pins Micro-Dconnector
M : 0~250V/2A/100W PSU-232 : An RS-232 cable including RJ-45 connector
*6: From 10%~90% of rated output voltage, with rated resistive load. PSU-485 : An RS-485 cable including RJ-45 connector
*7: From 90%~10% of rated output voltage, with rated resistive load. GTL-246 : A USB cable for TypeA-TypeB connectors
*8: Time for output voltage to recover within 0.1% + 10mV of its rated output for a : None
Interface Options:
load change from 50 to 100% of its rated output current. : USB(Type B)& RS-232/RS-485(RJ-45 connector) as default
*9: For load voltage change, equal to the unit voltage rating, constant input voltage. GL : LAN & GPIB(25 pins Micro-D connector)