Contents
1. Introduction......................................................................................................................... 3
2. Packing List......................................................................................................................... 3
3. Features................................................................................................................................ 3
4. Specifications..................................................................................................................... 3
5. Panel Layout....................................................................................................................... 4
5.1 Ethernet, Power............................................................................................................................ 4
5.2 RS-232/485/422 Port.....................................................................................................................6
5.3 LED indications............................................................................................................................ 6
6. Installation........................................................................................................................... 6
7. Software installation and setting................................................................................... 7
7.1 Software installation....................................................................................................................7
7.2 Virtual COM port setting.............................................................................................................9
7.2.1 Search serial device server NP301B.................................................................................... 9
7.2.2 Create virtual serial port.................................................................................................... 11
7.3 WinSock access setting........................................................................................................... 13
8. High level setting............................................................................................................. 14
8.1 Set PPPOE function...................................................................................................................14
8.2 Pass router setting.....................................................................................................................15
9. Application......................................................................................................................... 16
9.1 Virtual COM port......................................................................................................................... 16
9.2 Virtual serial connection.......................................................................................................... 16
10. FAQ.................................................................................................................................... 16
Page 2 of 16
LBNP16301B User Manual
1. Introduction
LBNP16301B is a high performance Ethernet to RS232/485/422 Ethernet bridge. LBNP16301B obtain
UDP or TCP data package, separate data package inside Ethernet, transfer the data through.
RS-232/485/422 interface according to the LBNP16301B setting demand. LBNP16301B obtain data from
RS-232/485/422 interface, pack to UDP or TCP format inside LBNP16301B, transfer the data to the
device through Ethernet port.
2. Packing List
3. Features
4. Specifications
Ethernet
Standard:10Base-T,100Base-TX
Speed:10/100M auto-sensing
Working: TCP Server, TCP Client, UDP and Real COM driver
Memory: Most 32Kbyte
Transmission: 100m
Electromagnetism isolate: 1KV
Connector: RJ45
Page 3 of 16
LBNP16301B User Manual
Serial
Standard: RS-232/RS-485/RS-422
Signals: RS-232:DCD,RXD,TXD,DTR,GND,DSR,RTS,CTS
RS-485:D+,D-,GND
RS-422:T+,T-,R+,R-,GND
Working mode: Asynchronous format, point to point, 2 wires half duplex, 4 wires full duplex
Parity: None, Even, Odd, Space, Mark
Data bits: 7bit, 8bit
Baud rate: 300bps ~115.2Kbps
Flow control: RTS/CTS
Direction control: RS485 side adopt ADDC technology, auto text and control data transfer
direction
Loading: RS-485/422 side support 32 nodes (customize 128 nodes) loopback
Transmission: RS-485/422 side 1200M,
RS-232 port 15M
Interface protection:1500W surge protection,
15KV ESD protection
Software
Network protocols: Support TCP, UDP, ARP, ICMP and DHCP
Driver support: Windows Real COM driver
(WindowsNT/2000,WindowsXP/2003)
Configuration options: SOCKET, Windows
Power
Power input: 12~36VDC
Consumption: 300mA
Environment
Working temperature:-20℃~60℃(-4F~140F)
Storage temperature:-25℃~85℃(-13F~185F)
Humidity: Relative humidity 5% to 95%
Appearance
Color: Black
L×W×H: 100mm×69mm×22mm
Material: Iron (Shell)
Weight: 240g
Warranty: 5 years
Approvals: FCC, CE, RoHS approvals
5. Panel Layout
Page 4 of 16
LBNP16301B User Manual
Power:
V-,FG,V+:12~36VDC input
RJ45 port support automatic MDI/MDI-X operation. can connect the PC, Server,
Converter and HUB by straight–though cable wiring . Pin 1, 2, 3, 6 Corresponding connection
in MDI. 1→3, 2→6, 3→1, 6→2 are used as cross wiring in the MDI-X port of Converter and
HUB. 10Base-T are used in MDI/MDI-X, the define of Pin in the table as below.
MDI(Straight-through cable):
RJ45
8
TX+ 3 3 RX+
TX- 6 6 RX-
RX+ 1 1 TX+
RX- 2 2 TX-
Page 5 of 16
LBNP16301B User Manual
5.2 RS-232/485/422 Port
DB9M
6. Installation
Page 6 of 16
LBNP16301B User Manual
DIN-Rail Installation
(1)Click “Next”
Page 7 of 16
LBNP16301B User Manual
(3)You can use “Change…” revise the location of the software installation
(4)Click “Next”
Page 8 of 16
LBNP16301B User Manual
(5)Click “Next”
Page 9 of 16
LBNP16301B User Manual
(2) Choose Tool menu IP-Search(Using this option searching LBNP16301B address in the
Ethernet and providing revise operation) option. You will send a serene as follows:
(4) Click the LBNP16301B IP address of the red circle, the IP address will present to the
green circle, setting the IP address to make sure that the IP address locate in the same
network segment, Click Alter after appearing correct hint, then click Refresh to check the
IP address changed or not in the red circle.
Page 10 of 16
LBNP16301B User Manual
7.2.2 Create virtual serial port
(1) Click button on the red circle choosing the COM port, Click Create COM port.
(2)Setting the parameter to this COM port.The IP Address and Port with red circle is show
for LBNP16301B. Choose On The Fly, Automatic obtain serial device parameter, do not
set by hand, you can also do not choose One The Fly to setting the parameter by hand.
Input the IP address into the IP Address, click “Add” button, you will see the screen as
follows:
Page 11 of 16
LBNP16301B User Manual
NOTE:
You can delete or edit the COM port through “Delete” and “Edit”. Finish these operation, the
device can communicate to the PC.
Page 12 of 16
LBNP16301B User Manual
7.3 WinSock access setting
Search Serial Device Server LBNP16301B
(1) Click “Start” → “Program” → “VirCOM”, Running the VSPort.exe(You can see the
screen as follows):
(2) Choose Tool menu IP-Search(Using this option searching LBNP16301B IP address in the
Ethernet and providing revise operation)option. You will send a serene as follows:
(3) Click Refresh button, procedure will search local network segment’s LBNP16301B and
display the device as follows diagram. If you want to modification the IP address of
LBNP16301B , Knock the red circle as follows. Then you will see the blue circle will
display the LBNP16301B IP address and SubMask. Knock “Alter” button,remember the
modification IP address. If do not modification , just remember the IP address of
LBNP16301B.
Page 13 of 16
LBNP16301B User Manual
Page 14 of 16
LBNP16301B User Manual
Instruction: “User Name” and “Password” input the User name and Password that telecom
distributed
“Connection Mode” is connection mode optional. Usually the mode is TCP Client
“Connection Port Number” and “Remote Host IP Address (For Client Only)”are far
server’s port number and IP address
Note: The serial parameter of the LBNP16301B must setting by hand with the same as the
serial device.
8.2 Pass router setting
Connect PC through Cross-over cable, set the PC IP address to a static IP address and let the
IP address locate in 192.168.200.X(X is not 200) network segment. Input 192.168.200.200
at the Web browser address. Input user name and password (default: admin). Enter into the
management interface as follows:
Page 15 of 16
LBNP16301B User Manual
Instruction:
“IP Address”, “Subnet mask” and “Gateway” input the IP address, Subnet mask and
Gateway that the LBNP16301B locate the network segment.
“Connection Mode” is connection mode optional. Usually the mode is TCP Client
“Connection Port Number” and “Remote Host IP Address (For Client Only)”are far
server’s port number and IP address
Setting finished, click “APPLY” button.
9. Application
10. FAQ