Chain Link Fencing - R0

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

8 7 6 5 4 3 2 1

F C F

G.I. WIRE
200 2900 200 2900 200 2900 200 200

G.I. WIRE
MS PLATE (2400x35x3)
FIXED TO THE POST

1800

1800
E E
B B CHAIN LINK FENCE AS PER
VENDOR SPECIFICATION
200

550
GROUND LEVEL G.I. WIRE D
150

800
CHAIN LINK FENCING (VENDER'S RCC CONCRETE PILLAR (M20)

400
SPECIFICATION) (PRECAST)

250
E E
VIEW -AA 500
(SCALE-1:30) RCC (N10)
C

450
(CAST-INSITU) 5-Y8

ROAD SIDE

1800
D D
MS-PLATE
ROAD SIDE

450
2900 2900 2900

DETAIL -D 100

P.ROW
A A (SCALE-1:20) 11000

400
200

(TYP)
PROW

P.ROW
FENCE PLAN (TYP)

200
RCC CONCRETE PILLER NATURAL GROUND LEVEL
(SCALE-1:30)

P.ROW

800
C C

Y8 @ 300 C/C
200 500
SECTION C-C
(SCALE-1:20)
40 100
200

500

5-Y8
NOTES:
B 1. FENCE OPENING & GI WIRE SHALL BE AS PER VENDOR SPECIFICATIONS. B
MS PLATE 2. HOOKS FOR HOLDING THE FENCE (5-Y8) SHALL BE PUT IN PLACE DURING CASTING OF CONCRETE POST.
100 3. RECEIVING SURFACE IN FOUNDATION SHALL BE LEVELED AND RAMMED.
4-Y8 4. PRECAST POST WITH HOOKS SHALL BE PUT IN PLACE AND BACKFILL SHALL BE RAMMED.
5. GI WIRE SHALL BE TIED TO THE HOOKS PLACED AT TOP AND BOTTOM MOST PART OF THE PRECAST CONCRETE POST.
SECTION A-A 6. CHAIN LINK FENCE SHALL BE STRETCHED AND PLACED IN POSITION.
Y8@125 C/C BOTHWAYS
(RC DETAILS) 4-Y8 7. MS PLATE WITH PRE DEFINED HOLES FOR HOOKS SHALL BE FIXED TO THE POST AND HOOKS SHALL BE BENT.
(SCALE-1:5) 8. THE HOOKS SHALL BE WELDED TO MS PLATE
SECTION E-E 9. ONE COAT OF RED OXIDE & REFLECTIVE PAINT SHALL BE APPLIED TO MS PLATE.
(RC DETAILS)
(SCALE-1:10)

M/S. VIJAY NIRMAN COMPANY PVT. LTD. & R.K.CHAVAN INFRASTRUCTURE PVT. LTD.(JOINT VENTURE)
A OWNER NATIONAL HIGHWAYS AUTHORITY OF INDIA EPC CONTRACTOR 105, 7TH MAIN, 4TH CROSS, MLA LAYOUT, RMV EXTENSION 2ND STAGE, BANGALORE - 560094, DRAWING TITLE A
M/S. DHRUV CONSULTANCY SERVICES LIMITED JOINT VENTURE WITH YONGMA TEL: 080-674333355 & 202, RAHUL ENCLAVE, WARJE PUNE - 411052, TEL: 020-25204294/95
AUTHORITY ENGINEERING CO. LTD. IN ASSOCIATE WITH CHO & KIM ENGINEERING PVT. LTD.
AEROTIDE INFRASTRUCTURE ENGINEERING PVT LTD DRAWN : P.W. CHECKED : P.S. SCALE : AS SHOWN
ENGINEER Head Office- 501, Plot No. 67, Pujit Plaza, Opp. K - Star Hotel, Sector-11, DESIGN CONSULTANT METHOD OF
UNIT 305,3RD FLOOR,GLOBE ESTATE,NEW KALYAN ROAD,MIDC PHASE-1,DOMBIVLI EAST,MUMBAI,- 421201.
C.B.D. Belapur, Navi Mumbai - 400 614 APPROVED : V.B. REVIEWED : P.G. DATE : 01-06-2022 PROJECTION
ARSHCONNEKT ENGINEERING CONSULTANTS LLP
PROOF
FOR REVIEW AND APPROVAL R0 01-06-2022 CONSULTANT 17 G/F,NIRMALKASTURI GREEN PARADISE,L/O SACRED,HEARTS ROAD,6TH CROS,NEAR FOUR LANNING OF NH-965G FROM KM 41.369 (BARAMATI) TO KM 83.500 (INDAPUR), DESIGN LENGTH DRAWING NO. -
IPC PRAYER GARDEN CHUR,BANGALORE,KARNATAKA,560036,INDIA SHEET NO. REV.
PROJECT NAME OF CONSULTANT
DESIGN CDF INFRA CON PVT LTD 42.131 KM AND ONE TIME IMPROVEMENT OF SELECTED STRETCHES (PACKAGE–II) IN THE STATE OF
DESCRIPTION REV. DATE SAFETY MAHARASHTRA ON EPC MODE UNDER BHARATMALA PARIYOJNA
DIRECTOR A 401,GOKUL CREST,SAKORE NAGAR,VIMAN NAGAR,PUNE,MAHARASHTRA,4110146 DRAWING NO. R0
CONSULTANT [email protected]