Flange , Plate , Pipe , PF Sheet & Physical & Chemical ASME Sec II & Approved
1 100% Review of MTC's MTC R R
Wool Properties Drawing
WPS/PQR/
2 WPS , PQR & WPQ Document Review Sample Review ASME Sec.IX R R
WPQ
ASME Sec VIII Div I Appendix 100% RT for Diffuser Assembly
3 Weld Soundness Surface Defect Free 100% NDT (PT/RT) Report P R
8,ASME Sec V ARTICALE 6 only.Refer Note 1
Hydro Test for Diffuser ASSY
ASME Sec VIII Div I & Hydro Test
4 Hydro test Leak Test 100% Visual & Leak test P W Only.(Hydro Test Pressure as per
Approved Drawing Report
GAD)
5 PMI Alloy Verification 100% Measurement ASME Sec VIII Div I Report W W
Visual &
6 Dimension & Visual Completeness 100% Approved Drawing Report R W
Measurement
7 Surface Preaparation Cleaning 100% Visual Approved Drawing Report R R
Report/Paint
8 Painting DFT 100% Visual Approved Drawing R W
Certificates
Final Inspection ( Critical Dimension
9 Verification 100% Visual & Dimension Approved Drawing Report W W Refer Note 2
& Workmanship)
R Review
H Hold
PRABU P Perform
P.R . ACOUSTICAL & ENGG. WORKS (P) LTD Material Test Certificates
TRICHY. Penetrant Test
Dry Film Thickness
Note 1 PT should be done for Outer Shell , Diffuser Assembly , Support Bracket & Lifting lug welding 1.Vendor
Note 2 Critical Dimension which are mentioned in the approved drawing only ( See Dimension Report ) 2.Thermax
Client