Rahim 2020 IOP Conf. Ser. Earth Environ. Sci. 476 012058

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

IOP Conference Series: Earth and Environmental Science

PAPER • OPEN ACCESS You may also like


- Bamboo Conditions for Processing
Investigation of bamboo as concrete reinforcement Bamboo Fiber with Combing Method
Qiang Jin, Wei Zhang and Wenbin Yao
in the construction for low-cost housing industry - Bonding Strength of Buluhpring Bamboo
Reinforcement Parallel and Non-Parallel
Notches U-Type in Concrete
To cite this article: N L Rahim et al 2020 IOP Conf. Ser.: Earth Environ. Sci. 476 012058 H Arifin, A A Afriansya and A A Amiruddin

- Chemical contents and thermal stability of


Madu bamboo (Gigantochloa albociliata)
for natural-bonded fiber composites
M S R Yusoff, S A Bahari, R M A A
View the article online for updates and enhancements. Haliffuddin et al.

This content was downloaded from IP address 103.19.139.242 on 21/01/2023 at 16:08


2nd International Conference on Civil & Environmental Engineering IOP Publishing
IOP Conf. Series: Earth and Environmental Science 476 (2020) 012058 doi:10.1088/1755-1315/476/1/012058

Investigation of bamboo as concrete reinforcement in the


construction for low-cost housing industry

N L Rahim1,2, N M Ibrahim1,2, S Salehuddin1, S A Mohammed1 and M Z


Othman1
1
School of Enviromental Engineering, University Malaysia Perlis, Kompleks Pusat
Pengajian Jejawi 3, 02600 Arau, Perlis Malaysia
2
Sustainable Environment Research Group (SERG), Centre of Excellence
Geopolymer and Green Technology (CEGeoGTech), School of Environmental
Engineering, Universiti Malaysia Perlis (UniMAP), Kompleks Pusat Pengajian Jejawi
3,02600 Arau, Perlis, Malaysia

E-mail: [email protected]

Abstract. Concrete is the most consumed material, with three tonnes per year used for every
person in the world. Twice as much concrete is used in construction as all other building
materials combined. Concrete has excellent characteristic in compressive strength, but low in
tensile strength. Steel commonly used in reinforcing material because of high tensile strength.
The usage of steel as reinforcing material is limited because it is costly and also has an effect
on air pollution during its manufacturing process. As an alternative to overcome this problem,
bamboo material has been used as a replacement of reinforcement in concrete. Bamboo is a
suitable material because it is a natural material, cheap and also available material. In this
research, the performance of bamboos as an alternative material in reinforced concrete has
been evaluated. Tensile strength test of bamboos has been performed to identify the yields
stress of bamboos. From the test, result has shown that bamboo has a similar characteristic with
steel and bamboo can be used as an alternative material for reinforcing concrete. However, the
characteristic of bamboos showed high water absorption and low bonding strength between
bamboo’s surface and concrete. In this research, a waterproofing agent has been used to
minimize water absorption and increase the bonding strength. Flexural strength test of the
bamboo singly reinforced beam with the size of 150 mm x 150 mm x 750 mm has been
undertaken to determine the performance of bamboo as reinforcement. From the test, it has
resulted that bamboo give good potential as an alternative material in concrete reinforcement
for low-cost housing industry.

1. Introduction
Concrete is an extensively used construction material for its various advantages such as low cost,
availability, fire resistance etc. But it cannot be used alone everywhere because of its low tensile
strength. The plain concrete possesses a very low tensile strength, limited ductility, and little resistance
to cracking. So, generally, steel is used to reinforce the concrete because steel has a high tensile
strength to complement the low tensile strength of concrete. In construction, the use of steel is very
costly and caused so much energy-consuming in its manufacturing process. Thus, a suitable material
must be used to substitute steel in construction. The material must provide availability with a low cost,
environmentally friendly and also less energy-consuming. Addressing all these problems, bamboo is

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution
of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
Published under licence by IOP Publishing Ltd 1
2nd International Conference on Civil & Environmental Engineering IOP Publishing
IOP Conf. Series: Earth and Environmental Science 476 (2020) 012058 doi:10.1088/1755-1315/476/1/012058

one of the suitable replacements of reinforcing bar in concrete for low-cost constructions. Bamboo is
easily accessible as it is available in almost every tropical and subtropical region.
One of the characteristics that would make bamboo an excellent substitute to steel in reinforced
concrete is its strength. The strength of bamboo is greater than many advantageous timber products,
but it is quite less than the tensile strength of steel. Bamboo is natural, cheap, widely available and
most importantly strong in both tension and compression. The tensile strength of bamboo is relatively
high and can attain 370 MPa [1], which makes bamboo an attractive substitute to steel in tensile
loading applications. This material can reduce the cost of construction and increases the strength of the
buildings that would otherwise be unreinforced. This paper aims to study the characteristic of the
bamboos for concrete reinforcement performance, investigate the characteristic yields stress of the
bamboo and to compare the bamboo and steel reinforcement for low-cost housing industry.

2. Material
Below are the materials that have been used in this study:

2.1. Selection and preparation of bamboo


For the sample selection of bamboo, the brown colour of bamboo with longer and great diameter
culms has been selected. Bamboo culms are cylindrical shells as shown in Figure 1, and are divided by
nodes as solid transversal diaphragms. The strength distribution is more uniform at the bottom of
bamboo than at the top or at the middle of it since it is subjected to maximum bending stress due to
wind at the top portion of the culms [1]. Based on the previous studies [2], the following criteria have
been measured in this research for the selection of bamboo culm for use as a reinforcement in the
concrete structures:
i. The bamboo showing a brown colour with at least three years old is selected.
ii. The accessible biggest diameter of the culm is being selected.
iii. The whole culm of green bamboo is not being used.
iv. Avoid cutting the bamboo in spring or early summer because the bamboo is weaker due to
increase in fibre and moisture content.
In this research, three years old bamboos plants of pronounced colour were selected. Samples (1 m
each) were collected from the bottom of the plant having four or five nodes.

Internodal Length
Culm
Node

Figure 1. Whole bamboo culm [2].

Bamboo sticks are generally more popular than whole culms in construction works. After cutting
the bamboo plant, it should be allowed to dry and season for three to four weeks before using. For the
sample preparation, bamboo has been allowed to dry for 30 days and split according to the suitable
dimension. The bamboos culms can be split or cut by using hand knife and machines equipment’s. In
this research, the dimension of 10 mm x 20 mm x 700 mm has been used for the sample preparation of
the beam reinforcement. The thickness of the sample varies throughout its length since it is a natural
material whose properties cannot be controlled strictly. For the tensile test, the diameter and length
that have been used for the testing was 10 mm x 300 mm. The specimens for concrete reinforcement
sample is shown in Figure 2.

2
2nd International Conference on Civil & Environmental Engineering IOP Publishing
IOP Conf. Series: Earth and Environmental Science 476 (2020) 012058 doi:10.1088/1755-1315/476/1/012058

Figure 2. Samples of bamboo used in concrete reinforcement.

2.2. Water-proof material


By referring to the previous study [3], the characteristic of bamboos showed high water absorption and
low bonding strength between bamboo’s surface and concrete when used as a reinforcement in
concrete. In order to prevent this problem, ‘Tack coat’ has been used to minimize the swelling of
bamboo and to increase the bonding strength. The coated has been applied one day before the
bamboos being used as a reinforcement in the beam sample.

2.3. Steel bar


High yield steel deformed (HYSD) were used in this study in order to identify the performance of
standard reinforcement used in concrete and to make a comparison with the bamboo reinforcement.

2.4. Concrete
The concrete to be used in the beams was made using Ordinary Portland Cement, sand as the fine
aggregate and stone chips as coarse aggregate with a maximum size of 20 mm. The concrete mix
proportion (cement: fine aggregate: coarse aggregate) was 1:2:4 with 0.5 water cement ratio used in
this study.

3. Methodology

3.1. Mechanical properties of bamboo


Mechanical properties are important to identify the characteristic strength of bamboo. All the
characteristic values were used in the design calculation. Based on the previous study [4], the equation
and design procedure can be used to design bamboo reinforced concrete if all mechanical properties
values were substitute in the reinforcement calculation. The mechanical properties have been
determined in this study by conducting few tests such as tensile test, compressive test and pull-out test.

3.1.1. Tensile test of bamboo stick. Bamboo sample with 300 mm length was selected for the tensile
test. The tensile tests were conducted for several samples on the specimen having no nodes at the
center across its length. During the tension test of bamboos reinforcement, an effort was prepared to
prevent the failure at the grip by covering the end of the specimen by galvanized wire. Appropriate
gripping is a significant factor in the tensile test to get the accurate result. According to [5], in order to
solve this gripping problem between surface of bamboos and machine, galvanized wires (2 mm
diameter) were wringed spirally at the both ends of the specimens. The use of galvanized wires spiral
around the ends of bamboos specimens has been presented in Figure 3.

3
2nd International Conference on Civil & Environmental Engineering IOP Publishing
IOP Conf. Series: Earth and Environmental Science 476 (2020) 012058 doi:10.1088/1755-1315/476/1/012058

Figure 3. Galvanized wire spiral around the ends of bamboo specimens.

3.1.2. Compressive strength test of bamboo. For the compressive strength test, the sample bamboo
with hollow culms of 150 mm were prepared with a different type of sample specimen was selected.
One of the sample specimens having a nodes and the other one without nodes was prepared as shown
in Figure 4. The dimension of each sample was measured and was placed in the UTM machine. From
the ultimate load graph, the compressive strength was determined.

Figure 4. Bamboo samples in compressive strength test.

3.1.3. Pull-out test. Pull-out test has been performed using the UTM machine to identify the bonding
strength between bamboo surface and concrete. Three different type of samples such a coated bamboo,
uncoated bamboo and steel have been tested. The test has been conducted according to [6] with the
length of bonding in concrete is 150 mm. The schematic diagram is shown in Figure 5. The bond
stress is determined from the ultimate load by using the formula of bond stress (unit are in N/mm2):

Zbd = P / π d Lb (1)
Where:
Zbd = bond stress
P = ultimate load at failure
d = diameter of specimen
Lb = lengths of bonding

4
2nd International Conference on Civil & Environmental Engineering IOP Publishing
IOP Conf. Series: Earth and Environmental Science 476 (2020) 012058 doi:10.1088/1755-1315/476/1/012058

Figure 5. Schematic diagram of specimen [6].

3.2. Beam specimen


In this research, the standard EUROCODE 2: design of concrete structures – part -1-1: General Rules
and Rules for Building [7] has been referred to design concrete by using bamboo reinforcement and
steel reinforcement. The load for the concrete sample has been assumed 25 kN/m (including
permanent and variable load). The mechanical properties have been changed for bamboo
reinforcements design which involved the values of characteristic strength of bamboo (fyk) and the
safety factor of the material. The characteristic strength of bamboo (fyk) is 168.31 N/mm2 (from the
tensile test). By referring to [8], the safety factor for the bamboo material is 1.5 or 2. In this study, the
factor of safety 2.0 has been used.
The size of bamboo reinforcement that has been used for concrete beam sample is 10 mm x 20 mm
and the steel bar reinforcement was 12 mm diameter. In this research, three types of beam were
produced namely bamboo reinforcement (BR2) with two pieces of bamboo reinforced, bamboo
reinforcement (BR6) with six pieces of bamboo reinforced and steel reinforcement (SR). The
dimension of beam is shown in Figure 6. The beams specimen has been designed for singly supported
to determine the feasibility of the bamboo reinforced in concrete reinforcement. The strength of the
beams is being determined by conducting the flexural test.

5
2nd International Conference on Civil & Environmental Engineering IOP Publishing
IOP Conf. Series: Earth and Environmental Science 476 (2020) 012058 doi:10.1088/1755-1315/476/1/012058

150 mm 750 mm

150 mm

Figure 6. Dimensions of sample beam.

According to [4], the placement of bamboo should not be placed fewer than 40 mm from the face
of the concrete surface. The suitable spacing between bamboo strips must not be fewer than the
maximum size of coarse aggregate. This is important to make sure the honeycomb will not occur
during the casting of the concrete. The bamboo strips have been strongly tight with galvanized wire
before casting process. Figure 7 showed the placement of bamboo before concrete casting.

Figure 7. Bamboo placement.

3.2.1. Compressive strength test (concrete cube). The concrete that has been used in the beams was
made by using Ordinary Portland Cement (OPC), sand as the fine aggregate and stones chips as coarse
aggregate with a maximum size of 20 mm. The cubes dimension is 150 mm x 150 mm x 150 mm.
After casting the concrete cubes, the concrete was demoulded after 24 hours and were placed for
curing for 28 days. Three cubes were tested at the age of 7 days and three cubes were tested at the age
of 28 days.

3.2.2. Flexural test for concrete beam. The beam was carefully placed under the testing machine and
support was placed at the measured location of 150 mm inside from each end. Figure 8 illustrates the
test setup. The deflection of the beam at mid-span was measured at regular interval of loading. From
the flexural test, the performance of reinforcement has been identified for the three types of
specimens.

6
2nd International Conference on Civil & Environmental Engineering IOP Publishing
IOP Conf. Series: Earth and Environmental Science 476 (2020) 012058 doi:10.1088/1755-1315/476/1/012058

Figure 8. Test setup for flexural test of the beam.

4. Results and discussion


Below are the result and discussion for this study.

4.1. Tensile test of bamboo stick


The tensile strength test was conducted using Universal Testing Machine (UTM). Specimen was
positioned in the machine and tensile load was applied until break. The tensile tests were conducted
for several samples which having no nodes at the center across its length. The result for tensile test can
be seen from the Table 1. From the result, the average stress is 169.27 MPa has been taken for the
three samples of bamboo specimen.

Table 1. Tensile stress of bamboo specimen.


Sample Area Ultimate load Stress (MPa)
(mm2) (kN)
1 200.00 34.03 170.17
2 200.00 32.04 160.20
3 200.00 35.49 177.45
Average 169.27

4.2. Compressive strength test of bamboo


The first type of specimen contains central nodes and the second types of specimen is without nodes.
The failure of bamboos was observed and from the result, it can be seen that the stress value obtained
for specimen without nodes is greater compared to the specimen with central nodes. The average
compressive stress of bamboos is 39.90 MPa. The results of the compressive test can be seen in Table
2.

Table 2. Result of compressive strength test for bamboo specimen.


Sample Maximum load (N) Compressive strength (MPa)
1 79.87 34.86
2 102.92 44.93
Average 39.90

7
2nd International Conference on Civil & Environmental Engineering IOP Publishing
IOP Conf. Series: Earth and Environmental Science 476 (2020) 012058 doi:10.1088/1755-1315/476/1/012058

4.3. Pull-out test of bamboo sticks and steel


Pull-out failure occurred due to the shear strength between the bamboo and concrete. From Table 3, it
shows that the bond stress of coated bamboo and uncoated bamboo are nearly the same. It is observed
that the bond stress of bamboo is 4.2 times less than steel.

Table 3. Pull-out test result for coated, uncoated bamboo and HYSD bar.
Sample Length of Bond stress of Bond stress of Bond stress of
bonding coated bamboo uncoated HYSD bar
(mm) bamboo
5.86
1 150.00 2.17 1.95
6.39
2 150.00 1.95 1.85
6.20
3 150.00 1.88 1.81
Average 2.00 1.87 6.15

4.4. Compressive strength test (concrete cube)


Compressive test was conducted to determine the compressive strength of the cement concrete cubes
of grades M20. The same mixed designed has been used as would normally be used with steel
reinforced concrete. The results obtained for compressive test are shown in Table 4.

Table 4. Result of compressive strength test on concrete cube.

Compressive
Sample Days Load (N) Average (MPa)
strength (MPa)

1 7 597.85 26.57
2 7 574.12 25.52 25.61

3 7 556.84 24.75
4 28 765.59 34.03
5 28 753.55 33.49 32.95

6 28 705.12 31.34

Target mean strength of concrete has been calculated in this research based on the study by [9].
Considering the inherent variability of concrete strength during production it is necessary to design the
mix to have a target mean strength which is greater than characteristic strength by a suitable margin.
The formula used to calculate target mean strength:

ft = fck + k × S (2)

Where:
ft = target of Strength
fck = characteristic strength of concrete
k = a constant depending upon the definition of characteristic strength
S = standard deviation of the particular mix

In this research, the value of k that has been used is equal to 1.65 where not more than 5% of the
test results were expected to fall below the characteristic strength. Table 5 and 6 show the value of
constant (k) and standard deviation (S). From the formula, concrete strength on 28 days was targeted

8
2nd International Conference on Civil & Environmental Engineering IOP Publishing
IOP Conf. Series: Earth and Environmental Science 476 (2020) 012058 doi:10.1088/1755-1315/476/1/012058

at 26.6 MPa as shown in Equation (3). From the result of compressive test for concrete cubes on 28
days (Table 4) showed the value of 32.95 MPa which is more than the target strength.

ft = 20 + 1.65(4.0) = 26.6 MPa (3)

Table 5. Value of statistical constant (k) [9].

Percentage of result below the


20 10 5 2.5 1
characteristic strength

Constant (k) 0.84 1.28 1.65 1.96 2.33

Table 6. Assumed standard deviation (S) [9]

Grade of concrete M10 M15 M20 M25 M30 M35 M40 M45
Standard deviation assumed
3.0 3.5 4.0 4.0 5.0 5.0 5.0 5.0
(N/mm2)

4.5. Flexural test for concrete beam


In this research, flexural test has been conducted for three beam specimens i.e. steel reinforced (SR),
two strips bamboo reinforced (BR2) and six strips bamboo reinforced (BR6). Figure 9 shows the
comparison strength between the three types of specimen. Based on the graph, three type of specimens
have shown the different value of strength. Steel reinforcement (SR) has shown the highest value of
strength with the ultimate load of 69.15 kN (for 7 days) and 110.37 kN (for 28 days) compared to
bamboo reinforcement with six’s strip (BR6) and bamboo reinforcement with two strips (BR2). For
BR2 specimens, the maximum load for 7 days is 51.8 kN and 76.80 kN for 28 days. This shows that
the BR2 beam can carry the load based on the design load of 25 kN/m. BR6 beam shows the ultimate
load of 62.13 kN (for 7 days) and 85.83 kN (for 28 days). Flexural test has been conducted for three
samples for each day that means three samples for 7 days and three samples for 28 days.

120

100
Ultimate Load (kN)

80

60 SR
BR6
40
BR2
20

0
0 5 10 15 20 25 30
Days

Figure 9. Strength comparison between SR, BR6 and BR2.

For the steel reinforcement beam (SR), the failure pattern of the beam specimen showed a ductile
failure. The firsts crack started at the central of the beam. The shear crack developed at the bottom of

9
2nd International Conference on Civil & Environmental Engineering IOP Publishing
IOP Conf. Series: Earth and Environmental Science 476 (2020) 012058 doi:10.1088/1755-1315/476/1/012058

the beam element and transmitted towards the central portion of the beam. The crack widened with the
increase of the load from the flexural test. The failure pattern of the SR beam reinforced can be seen in
Figure 10. For BR2 beam, crack also started at the central of the beam. The crack developed at the
bottom in tension zone of the beam element. The crack propagated vertically toward the top of the
beam. This proved that the beam was able to undertake shear load but weak to undertake the flexural
load. The crushing of the concrete also took place at the top of the beam. The beam failed in ductile
failure. The failures pattern of the beam is shown in Figure 11. BR6 beam also failed in ductile failure
similar with SR beam. The shear crack generated at the bottom of the beam element and propagated
towards the central portion of the beam as can be seen in Figure 12. The crack widened with the
increase of the load from the flexural test.

Figure 10. Failure pattern for SR beam. Figure 11. Failure pattern for BR2 beam.

Figure 12. Failure pattern for BR6 beam.

Some parameters during casting and preparation of sample also affect the strength of beam
specimen especially in compaction. Honeycomb was found in concrete specimen and this is one of the
parameters that affect the strength of the beam specimen. Another major factor that can be related with
the strength of bamboo reinforcement is the characteristic of the material. Bamboo is a material that
has high water absorption. Bonding strength between bamboo surface and concrete also affect the
strength of the concrete. From the pull-out test, it can be seen that the bonding stress of steel is higher
than bamboo.

5. Conclusion
This study provides bamboo as a potential reinforcement in concrete. From the flexural test of bamboo
reinforced beam, it has been seen that using bamboo as reinforcement in concrete can increases the
load carrying capacity of the beam. From the tensile test, it shows that bamboos have similar
behaviour like steel which consist the elastic characteristic. As bamboo is eco-friendly material,
limiting the use of steel can reduce the carbon dioxide emissions. In the green building concept, the
use of bamboo reinforced concrete may be recommendable. Further study must focus on how to
improve the bonding strength between bamboos and concrete. Water absorption of bamboo is very
high and waterproofing agent is recommended to minimize the water absorption during concrete
casting in order to improve the bonding strength between concrete and bamboo. The study should be

10
2nd International Conference on Civil & Environmental Engineering IOP Publishing
IOP Conf. Series: Earth and Environmental Science 476 (2020) 012058 doi:10.1088/1755-1315/476/1/012058

focusing on how to minimize the water absorption and improve the bonding strength by using suitable
waterproofing agent.

References
[1] Ghavami K 1995 Cement & Concrete Composites 17 pp 281-288
[2] Rahman M M 2011 International Journal of Engineering & Technology (IJET-IJENS) 11 (4) pp
142-146
[3] Ghavami K 2003 Cement & Concrete Composites 27 pp 637–649
[4] Sabnani C 2013 International Journal of Chemical, Environmental & Biological Sciences
(IJCEBS) 1 (2) pp 257-262
[5] Paulinmary B B 2013 International Journal of Engineering Research and Applications (IJERA)
3 (2) pp 683-686
[6] Sakaray H 2012 International Journal of Engineering Research and Applications
(IJERA) 2 pp 077-083.
[7] British Standards Institution 2005 EUROCODE 2: Design of concrete structures – part -1-1:
General Rules and Rules for Building. London, ISBN: 9780580454141
[8] Chung K F 2002 Engineering Structures 24 pp 429-442
[9] Krishnaswami B N 2009 Concrete Mix Design Civil Engineers & Architects Association
Kumbakonam Department of Civil Engineering Nit Trichy

11