Data Sheet M&EUR210EN

New: UR210 Series


AthalonTM Return Line Filters
Athalon™ maximum-life filters deliver the highest level of sustained fluid • K
 eeps fluids the cleanest, longest,
system protection, across all applications, regardless of severity. for the greatest value
Featuring an industry leading BetaX(C)=2000* filter efficiency; the • P
 rovides consistent, reliable,
highest rated filter performance available today. protection of system components
(* per ISO 16889) over the full service life of the filter
element
Notes and Specifications Filter Housing • R
 apidly achieves and sustains
required fluid system cleanliness
• Flows to 265 L/min (70 US gpm)
• D
 elivers maximum filter capacity in
• Pressures to 41 Bar (600 psi)
the smallest footprint
• Port Size 1” and 1¼”
• P
 revents electrostatic discharge
• Rated Fatigue Pressure: from damaging your filter and
41 bar (600 psi) per NFPA T2.06.01R2-2001 CAT C/90/*(1 million degrading your fluid
cycles), verified by testing at 0-48 bar (687 psi) for 1 million cycles.
Contact Pall for applications with higher pressures at lower cycles
Features
• Filter Element Burst Pressure:
• Patented Ultipleat (laid-over pleat)
10 bard (150 psid) filter medium pack
• Fluid Compatibility: • Pall Stress-Resistant Technology
Compatible with all petroleum oils and most water glycols, water-oil (SRT) Media
emulsions, and synthetic hydraulic and lubrication fluids
• Coreless filter element
• Temperature Range: configuration
Fluorocarbon Seals: • Low clean differential pressure for
-29 ˚C to 120 ˚C (-20 ˚F to 248 ˚F) low energy operation
60 ˚C (140 ˚F) maximum in HWCF or water glycol fluids
• Bypass Valve Setting:
4.5 bard (65 psid) or 1.7 bard (25 psid) UR210 Series
filter housing
• Indicator Pressure Setting:
3.5 bard (50 psid) or 1.1 bard (16 psid)
• Materials of Construction:
Head, cover and bowl: Aluminium Element Pressure Drop
• Filter Element : 210 Series Filter Elements – bard/1000 L/min (psid/US gpm)
Inorganic fibers impregnated and bonded with epoxy resins. Length Code AZ AP AN AS AT
Polymer endcaps. Anti-static media design 08 9.93 (0.545) 4.21 (0.231) 2.83 (0.155) 1.76 (0.096) 1.33 (0.073)
13 5.95 (0.327) 2.52 (0.139) 1.70 (0.093) 1.05 (0.058) 0.80 (0.044)
Pressure Drop Information 20 3.95 (0.217) 1.68 (0.092) 1.13 (0.062) 0.70 (0.038) 0.53 (0.029)
Housing pressure drop using fluid with 0.9 S.G.
270285 gravity.
Housing pressure drop is directly proportional to specific Multiply actual flow rate times factor in table below to determine
pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for
Flow (L/min) other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new
S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm
0 50 100 150 200 250
1.25
Sample ∆P calculation
15
1.0
UR210 Series 13” length housing with C20 BSPP ports using AN
grade media. Operating conditions 120 L/min flow rate using a
hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.
0.75
10
Total Filter ∆P
-16 Port = ∆P housing + ∆P element
0.5 = (0.18 x 1.2/0.9) bard (housing)
-20 Port + ((120 x 1.7/1000) x 50/32 x 1.2/0.9) bard (element)
5
= 0.24 (housing) + 0.43 bard (element)
0.25
P (bard)
P (psid)

= 0.67 bard (9.7 psid)

0 0
0 20 40 60 80

Flow (US gpm)

70
Ordering Information
For new installations, select one complete
part number from each section below

Section 1 Housing P/N: UR210 Section 2 Element P/N: UE 210


Table A Table 4 Note: Z indicates fluorocarbon seals are standard. Table 5 Table 3
Other options are available; contact Pall.
Note: Pall Athalon filter housings are supplied without filter elements or
warning devices fitted. Never operate the filter unless a filter element is
Table 5: Filter Element Options
fitted and all warning device ports are sealed.
Code ßx(c) ≥2000 based on ISO 16889 CST Rating* * CST: Cyclic
Note: Z indicates fluorocarbon seals are standard. Other options are available; Stabilization Test
AZ 3 07/04/01 to determine filter
contact Pall. Housing P/N designates indicator port fitted with a plastic shipping plug.
AP 5 11/08/03 rating under stress
conditions, based
AN 7 13/09/04 on SAE ARP4205
Table A
AS 12 15/11/06
Port & Length Options
Tables 1, 2 and 3 AT 25 16/14/08

A1608Z
A1613Z
A2008Z
Section 3 (At least one Differential Pressure Indicator or
‘B’ type blanking plug must be ordered)
A2013Z
A2020Z Differential Pressure Indicator P/N:
C1608Z RC Z Z
C1613Z
Table 6 Table 7
C2008Z
Note: If no differential pressure indicator Note: Z indicates fluorocarbon
C2013Z is selected, ‘B’ type blanking plug (P/N seals are standard. Other
C2020Z HC9000A104Z) must be ordered separately options are available;
and fitted to replace the plastic shipping plug. contact Pall.

Table 1: Housing Port Options Table 6: Indicator Options


Code Port Style Max. Operating Pressure Code Brass Option indicator
A SAE J1926 straight thread 41 bar (600 psi) A218M Electrical switch (SPDT) with Hirschmann connector
C BSP ISO 228 threads 41 bar (600 psi) A218R Electrical switch (SPDT) with Hirschmann connector
with Red and Green LED indicators
Table 2: Port Size Table 3: Housing Length and Seal Options A219D Visual indicator
Code Port Style Code Length and Seal Material Other options are available; contact Pall.
16 1” nominal 08Z 8” nominal length, fluorocarbon seals
Table 7: Indicator Pressue Setting Option
20 1 1/4” nominal 13Z 13” nominal length, fluorocarbon seals
Code Valve
20Z 20” nominal length, fluorocarbon seals
084 For ‘A’ Valve Option - Housings (1.1 bard - 16 psid)
091 For ‘G’ Valve Option - Housings (3.5 bard - 50 psid)
Table 4: Bypass Valve and Service Options
Other setting options are available; contact Pall.
Code Bypass Valve and Service Type
A 1.7 bard (25 psid) bypass valve, Head service
G 4.5 bard (65 psid) bypass valve, Head service

Seal Kit P/N: SR210SKZ


Other seal material options are available; Contact Pall.
Dimensional Drawings
Dimensions in mm (inches)

23.88 mm
0.94 in
48.64 mm
HEAD 1.92 in

INLET OUTLET
98.3 mm
3.87 in 84.07 mm
65.28 mm 3.31 in
2,57 in

90.17 mm
TORQUE BOWL 3.55 in
34/27 Nm
(25/20 LBFT)

08 - 349.8 (13.8 in)


13 - 484.4 mm (19.07 in)
20 - 654.6 mm (25.77 in)

BOWL

DRAIN/VENT PLUG
TORQUE TO 16/15Nm
(12/11 LBFT)
1/4” OD TO SAE J514
FOR A PORT
G1/4” TO ISO228 84.58 mm 76.2 mm
FOR C PORT 3.33 in 3.0 in

3X MOUNTING HOLES
TORQUE 14/19 Nm (10/14 lbft) 50.8 mm
MIN DISTANCE REQUIRED A - PORTS: 5/16”-18 UNC-2B
FOR ELEMENT REMOVAL 2.0 in
X . 38” DEEP MIN 25.4 mm
C - PORTS: M8X1 . 25-6H 1.0 in
X 9.5 mm DEEP MIN
ø 0.25

25.4 mm 12.7 mm
1.0 in 0.5 in 44.45 mm
1.75 in

The equipment has been assessed in accordance


with the guidelines laid down in The European
VENT PLUG
Pressure Directive 97/23/EC and has been classified TORQUE TO 16/15 Nm 32.77 mm
within Sound Engineering Practice S.E.P. Suitable for (12/11 LBFT) 49.15 mm 1.3 in
1/4” OD TO SAE J514 3.8 mm 1.94 in
use with Group 1 and 2 fluids only. Consult Sales for FOR A PORT 0.15 in
other fluid gas group suitability. G1/4” TO ISO228 60.96 mm
FOR C PORT 2.4 in
184.62 mm
5.3 in

25 Harbor Park Drive Visit us on the Web at www.pall.com


Port Washington NY 11050
Pall Corporation has offices and plants throughout the world. For Pall representatives
+1 516 484 3600 telephone in your area, please go to www.pall.com/contact
+1 800 289 7255 toll free US
Because of technological developments related to the products, systems, and/or
services described herein, the data and procedures are subject to change without
Portsmouth - UK notice. Please consult your Pall representative or visit www.pall.com to verify that
+44 (0)23 9233 8000 telephone this information remains valid.
+44 (0)23 9233 8811 fax
[email protected] © Copyright 2015, Pall Corporation. Athalon, Pall and are trademarks of Pall Corporation.
® Indicates a trademark registered in the USA. Better Lives. Better Planet and
Filtration. Separation. Solution.SM are service marks of Pall Corporation.

M&EUR210EN Printed in the UK February 2016

You might also like