Vertical Electrical
Vertical Electrical
Vertical Electrical
MECH. INSP.
- SEAT-F/O (4MS)
A. Referenced Information
REFERENCE DESIGNATION
Ref. AMM Operational Test of the Captain and First
25-11-00-710-001 Officer Seats
Ref. AMM Removal of the CAPT/F/O Seat
25-11-51-000-001
Ref. AMM Installation of the CAPT/F/O Seat
25-11-51-400-001
3. Fault Confirmation
SUBTASK 25-11-00-710-051-A
A. Test
(1) Do the operational test of the Captain and First Officer seats
(3MS, 4MS) Ref. AMM 25-11-00-710-001.
4. Fault Isolation
SUBTASK 25-11-00-810-051-A
A. If during the operational test the vertical electrical control of the First
Officer seat is inoperative:
MECH. INSP.