Health Device Profile
Health Device Profile
Bluetooth® Document
THIS DOCUMENT IS PROVIDED “AS IS” AND BLUETOOTH SIG, ITS MEMBERS, AND THEIR AFFILIATES MAKE NO REPRESENTATIONS OR
WARRANTIES AND DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY, TITLE,
NON-INFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE, THAT THE CONTENT OF THIS DOCUMENT IS FREE OF ERRORS.
TO THE EXTENT NOT PROHIBITED BY LAW, BLUETOOTH SIG, ITS MEMBERS, AND THEIR AFFILIATES DISCLAIM ALL LIABILITY ARISING
OUT OF OR RELATING TO USE OF THIS DOCUMENT AND ANY INFORMATION CONTAINED IN THIS DOCUMENT, INCLUDING LOST
REVENUE, PROFITS, DATA OR PROGRAMS, OR BUSINESS INTERRUPTION, OR FOR SPECIAL, INDIRECT, CONSEQUENTIAL, INCIDENTAL
OR PUNITIVE DAMAGES, HOWEVER CAUSED AND REGARDLESS OF THE THEORY OF LIABILITY, AND EVEN IF BLUETOOTH SIG, ITS
MEMBERS, OR THEIR AFFILIATES HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
This document is proprietary to Bluetooth SIG. This document may contain or cover subject matter that is intellectual propert y of Bluetooth
SIG and its members. The furnishing of this document does not grant any license to any intellectual property of Bluetooth SIG or its
members.
Copyright © 2021 by Bluetooth SIG, Inc. The Bluetooth word mark and logos are owned by Bluetooth SIG, Inc. Other third-party brands and
names are the property of their respective owners.
Hydra 0x1000 (4096 decimal) 11073-20601 IEEE 11073 Part 10101: Nomenclature; IEEE
11073-20601: Application profile – Optimized
Exchange Protocol
Pulse Oximeter 0x1004 (4100 decimal) 11073-10404 Health informatics - Personal health device
communication - Device specialization - Pulse
oximeter
Basic ECG (heart 0x1006 (4102 decimal) 11073-10406 Health informatics - Personal health device
rate) communication - Device specialization - Basic
ECG (heart rate)
Blood Pressure 0x1007 (4103 decimal) 11073-10407 Health informatics - Personal health device
Monitor communication - Device specialization - Blood
pressure monitor
Body 0x1008 (4104 decimal) 11073-10408 Health informatics - Personal health device
Thermometer communication - Device specialization – Body
thermometer
Body Weight 0x100F (4111 decimal) 11073-10415 Health informatics - Personal health device
Scale communication - Device specialization – Body
weight scale
Glucose Meter 0x1011 (4113 decimal) 11073-10417 Health informatics - Personal health device
communication - Device Specialization -
Glucose meter
International 0x1012 (4114 decimal) 11073-10418 Health informatics - Personal health device
Normalized communication - Device Specialization -
Ratio (INR) International Normalized Ratio (INR) Monitor
Monitor
Data Type MDEP Data Type(IEEE 11073- IEEE 11073 IEEE 11073 Document Name
10101 Nomenclature Data Document
Type Code) Number
Body 0x1014 (4116 decimal) 11073-10420 Health informatics - Personal health device
Composition communication - Device specialization - Body
Analyzer composition analyzer
Peak Flow 0x1015 (4117 decimal) 11073-10421 Health informatics - Personal health device
Monitor communication - Device specialization - Peak
flow monitor
Cardiovascular 0x1029 (4137 decimal)[Refer 11073-10441 Health informatics - Personal health device
Fitness and to Note 1 below] communication - Device specialization -
Activity Monitor Cardiovascular Fitness and Activity Monitor
Generic 0x1049 (4169 decimal) 11073-20601 IEEE 11073 Part 10101: Nomenclature; IEEE
11073-20601: Application profile – Optimized
Exchange Protocol
Step Counter 0x1068 (4200 decimal)[Refer 11073-10441 Health informatics - Personal health device
based on 10441 to Note 2 below] communication - Device specialization – Step
Counter based on 10441
Strength Fitness 0x102A (4138 11073-10442 Health informatics - Personal health device
Equipment decimal)[Refer to Note 1 communication - Device specialization -
below] Strength fitness equipment
Independent 0x1047 (4167 decimal)[Refer 11073-10471 Health informatics - Personal health device
Living Activity to Note 1 below] communication - Device specialization -
Hub Independent Living Activity Hub
Fall Sensor 0x1075 (4213 decimal)[Refer 11073-10471 Health informatics - Personal health device
to Note 3 below] communication - Device specialization - Fall
Sensor
Personal 0x1076 (4214 decimal)[Refer 11073-10471 Health informatics - Personal health device
Emergency to Note 3 below] communication - Device specialization -
Response Sensor Personal Emergency Response Sensor
Smoke Sensor 0x1077 (4215 decimal)[Refer 11073-10471 Health informatics - Personal health device
to Note 3 below] communication - Device specialization - Smoke
Sensor
Carbon 0x1078 (4216 decimal)Refer 11073-10471 Health informatics - Personal health device
Monoxide (CO) to Note 3 below] communication - Device specialization -
Sensor Carbon Monoxide (CO) Sensor
Data Type MDEP Data Type(IEEE 11073- IEEE 11073 IEEE 11073 Document Name
10101 Nomenclature Data Document
Type Code) Number
Water Sensor 0x1079 (4217 decimal)Refer 11073-10471 Health informatics - Personal health device
to Note 3 below] communication - Device specialization - Water
Sensor
Gas Sensor 0x107A (4218 decimal)Refer 11073-10471 Health informatics - Personal health device
to Note 3 below] communication - Device specialization - Gas
Sensor
Motion Sensor 0x107B (4219 decimal)Refer 11073-10471 Health informatics - Personal health device
to Note 3 below] communication - Device specialization -
Motion Sensor
Property Exit 0x107C (4220 decimal)Refer 11073-10471 Health informatics - Personal health device
Sensor to Note 3 below] communication - Device specialization -
Property Exit Sensor
Enuresis Sensor 0x107D (4221 decimal)Refer 11073-10471 Health informatics - Personal health device
to Note 3 below] communication - Device specialization -
Enuresis Sensor
Contact Closure 0x107E (4222 decimal)Refer 11073-10471 Health informatics - Personal health device
Sensor to Note 3 below] communication - Device specialization -
Contact Closure Sensor
Usage Sensor 0x107F (4223 decimal)Refer 11073-10471 Health informatics - Personal health device
to Note 3 below] communication - Device specialization - Usage
Sensor
Switch Sensor 0x1080 (4224 decimal)Refer 11073-10471 Health informatics - Personal health device
to Note 3 below] communication - Device specialization - Switch
Sensor
Medication 0x1081 (4225 decimal)Refer 11073-10471 Health informatics - Personal health device
Dosing Sensor to Note 3 below] communication - Device specialization -
Medication Dosing Sensor
Temperature 0x1082 (4226 decimal)Refer 11073-10471 Health informatics - Personal health device
Sensor to Note 3 below] communication - Device specialization -
Temperature Sensor
Medication 0x1048 (4168 decimal) 11073-10472 Health informatics - Personal health device
monitor communication - Device specialization -
Medication monitor
Data Type MDEP Data Type(IEEE 11073- IEEE 11073 IEEE 11073 Document Name
10101 Nomenclature Data Document
Type Code) Number
Power Status 0x101c (decimal 4124) 11073-10427 Health infomatics - Personal health device
Monitor communication - Part 10427: Device
specialization - Power Status Monitor of
Personal Health Devices
All other values 0xXXXX
reserved