PRODUCT HIGHLIGHTS
12 or 24 VDC input
Maximum Output Voltage
Maximum Iout capability down to 0 VDC
10 or 15 kV DC
Output ripple performance as low as 80 ppm (0.8 Vpp)
ELECTRICAL SPECIFICATIONS
High Voltage Output Range (Adjustable Regulated, Positive or Negative)1 0 to 10,000 VDC 0 to 15,000 VDC
DC Input
Vin (Input Voltage) Range VDC (positive polarity only) 11 to 16 23 to 30 11 to 16 23 to 30
Vpp (standard configuration) < 1.2 <4 < 7.6 < 3.6 < 6.5 < 12
Vpp (with -F-M option) < 0.8 < 3.4 < 7.2 < 3.2 < 4.2 < 11
Vpp (with -F-M-C option) <2 <3 <5 <3 < 4.5 < 7.5
1 Standard product specifications shown unless noted. Custom configurations are available.
2 Nominal ripple measured @ 100% HVout, 100% LOAD into 300 pf bypass capacitor. Valid for 10 to 100% HVout range.
3 ppm = parts per million @ 100% HVout. Vpp = VDC peak to peak @ 100% HVout.
Stability 0.01% (100 ppm) @ 100% HVout (after 30 min warmup interval)
0.02% (200 ppm) @ 100% HVout (per 8 h interval)
Line Regulation 0.01% (100 ppm) @ 100% HVout, 100% Pout, Vin (nominal)
Static Load Regulation 0.01% (100 ppm) @ 100% HVout, 0 to 100% LOAD
Environmental
Regulatory
2 advancedenergy.com
ULTRAVOLT 10A AND 15A SERIES
MECHANICAL SPECIFICATIONS
L6
L4 L5
L3
L2 W6
W1 L1 Not to Scale
J1-1 -8
-2 -9
A
-3 -10
W2 -4 -11
-12
W7 W4 W5 W
-5
-6 -13 B
-7 -14 J2-1 J2-2
L
J1 Header J2 Header Flying Lead
H2
H1
H
HVout
L4 Centerline, J1-1 to J2-1 45.7 1.80 45.7 1.80 Optional Shield Six-sided Mu-Metal
(-M option)
L5 Centerline, J2-1 to J2-2 2.5 0.10 2.5 0.10
Labels Static-dissipative
L6 Centerline, J1-1 to Flying Lead 77.5 3.05 102.5 4.04 polyester
W Overall Width 38.7 1.53 38.7 1.53 Cooling Natural convection
W1 Case Exterior to J1-1 3.8 0.15 3.8 0.15 and conduction
W2 Centerline, J1-1 to J1-7 30.5 1.20 30.5 1.20 Encapsulation Silicone-based RTV
(contact factory
W3 Centerline, J1-6 to J1-7 5.1 0.20 5.1 0.20
for other options)
W4 Centerline, J1-1 to J2-1 26.7 1.05 26.7 1.05
Pins Gold-plated bronze
W5 Centerline, J1-1 to Flying Lead 29.7 1.17 29.7 1.17
1 Approximate nominal dimensions and weights for
W6 Centerline, J1-1 to Hole A 1.3 0.05 1.3 0.05 standard configuration shown. Contact factory
for -M, -C or -E case options.
W7 Centerline, Hole A to Hole B 27.9 1.10 27.9 1.10
2 Standard case (DAP plastic) tolerances
H Case Height (Case Exterior to PCB , max) 25.4 1.00 25.4 1.00
are ±1.27 mm (±0.050 in). Pin-to-pin tolerances
H1 Base of PCB to J1/J2 Header Tip 11.2 0.44 11.2 0.44 are ±0.76 mm (±0.015 in).
H2 Length of Standard Flying Lead 470 18.5 470 18.5 3 Refer to outline drawings and 3D models
for detailed information.
g oz g oz
advancedenergy.com 3
ULTRAVOLT 10A AND 15A SERIES
INTERFACE
The 10A and 15A series’ standard interface permits voltage control and monitoring of both voltage and current output
using analog DC signals whose range and polarity vary by model. The 10A model also offers UltraVolt’s optional -I5 or
–I10 interface which provides simplified control and monitoring of both voltage and current using 0 to 5 VDC or 0 to 10
VDC full-scale analog signals.
J1-4 Enable HVret J2-1 J1-7 Vref Output Control Signal Reference 2
+
J1-2 Vin R C J2-1 HVret Ground High Voltage Return 9
F
J1-1 Gnd J2-2 Vmon Output Monitor HVout Voltage Level
Pin Flying Lead HVout Output High Voltage Output
Case Mounting Screws
Mu-Metal Shield (-M Option)
Mounting Flange (-E Option)
Aluminum Case (-C Option)
J1-12 Vmode
10 VDC (-I10 Option)
Iout J1-1 Gnd Ground DC Input Power Ground
J1-3 Imon J1-2 Vin Input DC Input Power
Example
J-11 Imode J1-3 Imon Output Monitor HVout Current Level 3, 8
Interface Circuit
J1-4 Enable HVret J2-1 J1-7 Vref Output Control Reference Signal 5, 6
J2-2
J1-2 J1-8 Gnd Ground DC Input Power Ground
+ J1-9
Vin R C
F
J1-1 J1-9 Vin Input DC Input Power
Gnd
J1-8
Pin
J1-10 N/C No Connection
Case Mounting Screws
Mu-Metal Shield (-M Option) J1-11 Imode Output Current Mode Indicator 7
Mounting Flange (-E Option)
Aluminum Case (-C Option) J1-12 Vmode Output Voltage Mode Indicator 7
3 Can source an output impedance load > 10 kΩ 7 LOW = Mode ENABLED (open drain) will sink up to 30 mA.
4 Signal input: LOW < 0.5 VDC, HIGH > 2.4 VDC (Default or N/C = DISABLED = LOW)
8 Voltage/current monitors will source/sink to 2 mA.
5 -I5 interface: 5 VDC ±0.1% @ 5 mA (nominal at case temperature = 25°C, 77°F)
9 For proper operation and safety, always route HVret signal through HVret
6 -I10 interface: 10 VDC ±0.1% @ 5 mA (nominal at case temperature = 25°C, 77°F) connection.
4 advancedenergy.com
ULTRAVOLT 10A AND 15A SERIES
Scale Factors 1, 2, 3 SVm (V/V) where HVout Monitor = SVm x Vmon 1000 1000
Positive Polarity Models SVp (V/V) where HVout Control = SVp x Vprog 2155 3233
Negative Polarity Models SVp (V/V) where HVout Control = SVp x (5 - Vprog) -2155 -3233
Slm (mA/V) where Iout Monitor = SIm x Imon 0.167 0.184 0.381 0.158 0.181 0.378
Scale Factors 5, 6, 8, 9 SVm (V/V) where HVout Monitor = SVm x Vmon 2000 N/A
SIm (mA/V) where Iout Monitor = SIm x Imon 0.08 0.30 0.60 N/A
SIp (mA/V) where Iout Control = SIp x Iprog 0.08 0.30 0.60 N/A
Scale Factors 5, 7, 8, 9 SVm (V/V) where HVout Monitor = SVm x Vmon 2000 N/A
SIm (mA/V) where Iout Monitor = SIm x Imon 0.04 0.15 0.3 N/A
SIp (mA/V) where Iout Control = SIp x Iprog 0.04 0.15 0.3 N/A
Input Voltage Protection F (fuse or other protection recommended) See note 10 See note 10
1 For positive polarity models, Vprog varies from 0 to 4.64 VDC. For negative 7 For the -I10 interface, Imon, Iprog, Vmon, and Vprog input/output signals vary
polarity models, Vprog varies inversely from 5 to 0.36 VDC. from 0 to 10 VDC (full-scale).
2 SIm factor is ±2% @ 100% LOAD, 100% HVout. Valid for 10 to 100% Iout range. 8 SVm factor is ±1% for both -I5 and -I10 Interfaces. SVp factor is also ±1%
and is valid from 10 to 100% HVout.
3 SVm factor is ±2% assuming a 10 MΩ measurement impedance.
Valid from 10 to 100% HVout. 9 SIm factor is ±1% for both -I5 and -I10 Interfaces. SIp factor is also ±1%
and is valid from 10 to 100% Iout.
4 See interface schematics for definition.
5 For details on -I5/-I10 interfacing, see technical note TN-I5-I10-1. 10 For details on fuse selection, see technical note TN-23.
6 For the -I5 interface, Imon, Iprog, Vmon, and Vprog input/output signals vary
from 0 to 5 VDC (full-scale).
advancedenergy.com 5
ULTRAVOLT 10A AND 15A SERIES
STANDARD OPTIONS
Both the 10A and 15A series can be configured with standard options that can adapt its performance and
packaging for many application requirements. Customized models to meet specialized performance, packaging,
or environmental needs are also available.
Featured Options
-I5 Upgrades interface to provide more precise control and monitoring of both HVout and Iout using 0 to 5 VDC (full-scale) analog
signals. Also adds Iout control and voltage/current mode indication capability not available on the standard interface. Cannot be
ordered with the -I10 option. Available only on 10A series models.
-I10 Upgrades interface to provide more precise control and monitoring of both HVout and Iout using 0 to 10 VDC (full-scale) analog
signals. Also adds Iout control and voltage/current mode indication capability not available on the standard interface. Cannot be
ordered with the -I5 option. Available only on 10A series models with 24 VDC input.
-F Reduces high voltage ripple when used together with the Mu-Metal shield and a user-supplied external capacitive load.
Available only with the the Mu-Metal shield (-M option).
-M Adds a Mu-Metal shield to reduce the effects of external RF noise sources. Installed on six sides, this shield option
is available on both standard plastic (DAP) and optional aluminum (-C option) cases.
-E Eared mounting flange that permits the standard plastic (DAP) case to be chassis-mounted.
-C Aluminum alloy case with integrated mounting flange that provides both added RF and environmental protection.
-AP Adds non-conductive braiding to the standard HVout flying lead for increased durability. Terminating connector is user-supplied.
Not available with the -WS option.
-WS Replaces the standard HVout flying lead with a 470 mm long shielded coaxial cable for added RF protection.
Terminating connector is user-supplied. Not available with the -AP option.
-25PPM Upgrades module temperature coefficient rating from 50 ppm/°C to 25 ppm/°C for enhanced high voltage output
stability over standard operating temperature ranges.
-H Heatsink option
Standard Interface -I5 and -I10 Interface -E Option (Eared Mounting Plate) -C Option (Aluminum Case)
-H Heatsink
6 advancedenergy.com
ULTRAVOLT 10A AND 15A SERIES
ORDERING INFORMATION
Interfaces Mechanical
Standard Select
Select One Select One
Electrical Performance Features One Ripple Temp
Standard Interface
Plastic Case (DAP)
Other Options
Heatsink
Standard Part
10A24-N15-I10-F-M-C-WS
Output Voltage
Output
Power
Model
Output Polarity
Input Voltage
advancedenergy.com 7
DS TITLE
ENG-HV-10A15A-235-02 7.19