100% found this document useful (1 vote)
558 views19 pages

Z-Purlin Data Sheet Rev06. 19-2-17

The document provides specifications for Z-Purlins, which are secondary structural members used to support roof sheeting and wall cladding. Key details include: - Z-Purlins are characterized by having a high strength to weight ratio and being economical. They can be used for large spans up to 11 meters. - Material specifications include galvanized steel between 1.5mm to 3.0mm thickness. Yield strengths range from 345 to 500 MPa. - Charts provide section properties and dimensions for various purlin profiles with depths from 100mm to 450mm.

Uploaded by

Akhil VN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
558 views19 pages

Z-Purlin Data Sheet Rev06. 19-2-17

The document provides specifications for Z-Purlins, which are secondary structural members used to support roof sheeting and wall cladding. Key details include: - Z-Purlins are characterized by having a high strength to weight ratio and being economical. They can be used for large spans up to 11 meters. - Material specifications include galvanized steel between 1.5mm to 3.0mm thickness. Yield strengths range from 345 to 500 MPa. - Charts provide section properties and dimensions for various purlin profiles with depths from 100mm to 450mm.

Uploaded by

Akhil VN
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 19

Cold Formed Profile Z—Purlin

Technical Data Sheet & Load Tables Page 1 of 19

PRODUCT DESCRIPTION

Our Z-Purlins are the secondary structural members used to support the roof sheeting / wall cladding.
Besides being economical to use, they give an excellent strength- to- weight ratio, thus providing substantial
cost savings.

Our Z-Purlins are characterized by:


 Having a high strength to weight ratio
 Being economical;
 Being usable for large spans upto 11.0m;
 Being quickly installed

Material and Product Specifications


Usage Structural member
Material
Galvanized Iron (GI) Structural Steel (SS), Grade 50 Class 1,
ASTM A 653M
Coating /Finish G90 (275 grams/m2 Zinc Coating)
Minimum Specified Yield strength FY 345 N/mm²
Material thickness 1.5 mm to 3.0 mm
Purlin length Up to 11 meters
Purlin depth (d) 100 mm to 450 mm
A) Design of Purlins is based on AISI- 2012(ASD-Allowable Stress
Notes applicable for all following Design Method)
pages B) Allowable loads applicable up to slopes of 3:10only
C) Allowable capacities for uplift loads are not increased.
D) Sag rods are located at equal distances
E) For laps please refer General Structural Detail sheet

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 2 of 19

GENERAL PROPERTIES SECTION PROPERTIES

Section Weight d t a b c lx defl Sx (b) Sxe(t) Sxe(b)


sx(t) Rx ly Sy Ry
Kg/m (mm) (mm) (mm) (mm) (mm) cm4 cm3 cm3 cm3 cm3 cm cm4 cm3 cm
122Z15 2.92 122 1.50 55 50 17 88.500 14.800 14.230 13.099 13.922 4.864 29.920 4.610 2.828
142Z15 3.21 142 1.50 55 50 20 128.900 18.480 17.830 17.203 17.600 5.585 33.650 5.010 2.854
142Z18 3.85 142 1.8 55 50 20 153.300 21.990 21.210 21.990 21.210 5.571 39.900 5.960 2.842
142Z20 4.29 142 2.00 55 50 20 169.300 24.290 23.430 24.290 23.430 5.561 43.990 6.580 2.834
142Z25 5.36 142 2.50 55 50 20 208.600 29.920 28.860 29.920 28.860 5.537 53.910 8.090 2.815
172Z15 3.45 172 1.50 55 50 15 194.000 22.950 22.190 20.040 21.490 6.617 27.580 4.330 2.495
172Z18 4.14 172 1.80 55 50 15 231.000 27.320 26.420 25.690 26.080 6.602 32.680 5.140 2.483
172Z20 4.60 172 2.00 55 50 15 255.300 30.200 29.200 28.820 28.920 6.592 36.010 5.670 2.476
172Z25 5.75 172 2.50 55 50 15 315.000 37.250 36.020 37.250 36.020 6.567 44.080 6.970 2.457
182Z15 3.57 182 1.50 55 50 16 223.700 24.980 24.190 22.110 23.490 6.965 28.740 4.460 2.497
182Z18 4.28 182 1.80 55 50 16 266.400 29.750 28.810 29.690 28.490 6.950 34.070 5.300 2.485
182Z20 4.76 182 2.00 55 50 16 294.500 32.890 31.850 31.740 31.620 6.939 37.550 5.840 2.478
182Z25 5.95 182 2.50 55 50 16 363.500 40.600 39.300 40.600 39.300 6.914 45.960 7.180 2.459
202Z15 3.92 202 1.50 60 55 16 301.700 30.320 29.440 26.290 28.410 7.721 35.860 5.160 2.662
202Z18 4.7 202 1.80 60 55 16 359.600 36.130 35.080 32.500 34.200 7.705 42.540 6.130 2.650
202Z20 5.23 202 2.00 60 55 16 397.700 39.960 38.800 37.490 38.250 7.695 46.910 6.770 2.643
202Z25 6.53 202 2.50 60 55 16 491.400 49.380 47.940 48.050 47.670 7.670 57.510 8.330 2.624
232Z15 4.53 232 1.50 70 65 17 462.700 40.400 39.380 31.970 37.540 8.900 55.220 6.890 3.075
232Z18 5.44 232 1.80 70 65 17 551.900 48.190 46.980 41.400 45.210 8.884 65.610 8.200 3.063
232Z20 6.04 232 2.00 70 65 17 610.800 53.340 51.990 45.880 50.050 8.874 72.420 9.060 3.056
232Z25 7.55 232 2.50 70 65 17 755.900 66.010 64.340 62.070 63.450 8.849 89.020 11.170 3.037
252Z15 4.76 252 1.50 70 65 16 558.900 44.900 43.820 34.060 41.650 9.563 53.410 6.710 2.956
252Z18 5.71 252 1.80 70 65 16 666.800 53.580 52.290 46.120 50.240 9.547 63.440 7.990 2.945
252Z20 6.34 252 2.00 70 65 16 738.100 59.310 57.870 50.940 55.570 9.537 70.020 8.830 2.937
252Z25 7.93 252 2.50 70 65 16 913.900 73.430 71.660 68.630 70.470 9.511 86.060 10.880 2.918
262Z15 5.18 262 1.50 80 72 20 672.800 52.300 50.450 38.150 47.850 10.069 81.490 8.890 3.504
262Z18 6.22 262 1.80 80 72 20 803.200 62.430 60.230 51.100 57.530 10.054 96.930 10.590 3.493
262Z20 6.91 262 2.00 80 72 20 889.300 69.130 66.680 58.870 64.050 10.044 107.070 11.710 3.485
262Z25 8.63 262 2.50 80 72 20 1101.900 85.660 82.620 75.890 80.220 10.019 131.890 14.460 3.466
302Z18 6.85 302 1.80 85 80 16 1159.100 77.550 75.990 54.030 71.170 11.483 106.240 11.250 3.477
302Z20 7.61 302 2.00 85 80 16 1283.800 85.900 84.170 64.840 79.330 11.473 117.370 12.440 3.469
302Z25 9.52 302 2.50 85 80 16 1592.200 106.530 104.380 87.610 98.900 11.447 144.640 15.370 3.450
302Z30 11.42 302 3.00 85 80 16 1895.800 126.850 124.18 115.05 116.09 11.430 171.00 18.840 3.430
342Z20 8.76 342 2.00 100 92 20 1932.030 114.08 110.90 77.570 77.170 13.100 193.680 12.940 4.138
342Z25 10.87 342 2.50 100 92 20 2387.65 141.63 137.680 114.36 112.82 13.670 239.096 16.430 4.120
342Z30 13.16 342 3.00 100 92 20 2845.67 168.810 164.080 145.18 147.000 13.041 283.345 21.389 4.102

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 3 of 19

BUTT JOINT SYSTEM


Working Loads
Weight Total Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN [Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 3.50 metres
122Z15 2.92 5.04 1.44 1.20 0.96 0.80 0.72 6.16 3.25 5.13 - -
142Z15 3.21 6.23 1.78 1.48 1.19 0.99 0.89 8.96 4.21 6.31 - -
142Z18 3.85 8.05 2.30 1.92 1.53 1.28 1.15 10.68 5.00 8.13 - -
142Z20 4.29 9.28 2.65 2.21 1.77 1.47 1.33 11.80 553 9.39 - -
142Z25 5.36 12.53 3.58 2.98 2.39 1.99 1.70 14.53 6.81 12.43 - -
Span 4.00 metres
122Z15 2.92 4.44 1.11 0.93 0.74 0.62 0.56 4.72 2.84 4.49 - -
142Z15 3.21 5.48 1.37 1.14 0.91 0.76 0.69 6.88 3.68 5.52 - -
142Z18 3.85 7.04 1.76 1.47 1.17 0.98 0.88 8.20 4.38 7.10 - -
142Z20 4.29 8.12 2.03 1.69 1.35 1.13 1,02 9.00 4.82 8.21 - -
142Z25 5.36 10.96 2.74 2.28 1.83 1.52 1.37 11.08 5.96 10.19 - -
172Z15 3.45 6.28 1.57 1.31 1.05 0.87 0.79 10.28 4.32 6.38 - -
BUTT SYSTEM

172Z18 4.14 8.20 2.05 1.71 1.37 1.14 1.03 12.28 5.30 8.31 - -
172Z20 4.6 9.52 2.38 1.98 1.59 1.32 1.19 13.60 6.03 9.48 - -
172Z25 5.75 13.08 3.27 2.73 2.18 1.82 1.64 16.80 7.44 11.73 - -
Span 4.50 metres
142Z15 3.21 4.86 1.08 0.90 0.72 0.60 0.54 5.40 3.28 4.90 - -
142Z18 3.85 6.26 1.39 1.16 0.93 0.77 0.70 6.44 3.90 6.11 - -
142Z20 4.29 7.25 1.61 1.34 1.07 0.89 0.81 7.16 4.30 6.76 - -
142Z25 5.36 9.77 2.17 1.81 1.45 1.21 1.09 8.78 5.30 8.40 - -
172Z15 3.45 5.58 1.24 1.03 0.83 0.69 0.62 8.15 3.84 5.67 - -
172Z18 4.14 7.29 1.62 1.35 1.08 0.90 0.81 9.77 4.72 6.82 - -
172Z20 4.6 8.46 1.88 1.57 1.25 1.04 0.94 10.71 5.36 7.55 - -
172Z25 5.75 11.61 2.58 2.15 1.72 1.43 1.29 13.32 6.61 9.38 - -
182Z15 3.57 6.08 1.35 1.13 0.90 0.75 0.68 9.41 4.24 6.13 - -
182Z18 4.28 7.92 1.76 1.47 1.17 0.98 0.88 11.25 5.23 7.50 - -
182Z20 4.76 9.18 2.04 1.70 1.36 1.13 1.02 12.47 5.85 8.31 - -
182Z25 5.95 12.6 2.80 2.33 1.87 1.56 1.40 15.39 7.22 10.32 - -
202Z15 3.92 6.93 1.54 1.28 1.03 0.86 0.77 12.78 4.88 7.01 - -
202Z18 4.7 9.05 2.01 1.68 1.34 1.12 1.01 15.12 6.12 9.17 - -
202Z20 5.23 10,58 2.35 1.96 1.57 1.31 1.18 16.65 6.87 10.70 - -
202Z25 6.53 14.76 3.28 2.73 2.19 1.82 1.64 20.75 8.75 14.59 - -

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 4 of 19

BUTT JOINT SYSTEM


Working Loads
Weight Total Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN [Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 5.00 metres
172Z15 3.45 5.00 1.00 0.83 0.67 0.56 0.50 6.60 4.45 5.04 - -
172Z18 4.14 6.55 1.31 1.09 0.87 0.73 0.66 7.85 5.33 6.38 - -
172Z20 4.6 7.65 1.53 1.28 1.02 0.85 0.77 8.7 5.92 7.05 - -
172Z25 5.75 10.45 2.09 1.74 1.39 1.16 1.05 10.75 7.41 8.71 - -
182Z15 3.57 5.45 1.09 0.91 0.73 0.61 0.55 7.65 4.93 5.52 - -
182Z18 4.28 7.10 1.42 1.18 0.95 0.79 0.71 9.05 - 5.89 7.03 -
182Z20 4.76 8.25 1.65 1.38 1.10 0.92 0.83 10.10 6.53 7.77 - -
182Z25 5.95 11.35 2.27 1.89 1.51 1.26 1.14 12.45 8.16 9.59 - -
202Z15 3.92 6.25 1.25 1.04 0.83 0.69 0.63 10.35 6.31 6.31 - -
202Z18 4.7 8.15 1.63 1.36 1.09 0.91 0.82 12.35 7.87 8.25 - -
202Z20 5.23 9.50 1.90 1.58 1.27 1.06 0.95 13.55 8.72 9.62 - -
202Z25 6.53 13.3 2.66 2.22 1.77 1.48 1.33 16.8 12.54 13.13 - -
4.53 7.60 1.52 1.27 1.01 0.84 0.76 15.8 7.70 7.70 - -
BUTT SYSTEM

232Z15
232Z18 5.44 10.0 2.00 1.67 1.33 1.11 1.00 18.85 10.09 10.09 - -
232Z20 6.04 11.65 2.33 1.94 1.55 1.29 1.17 20.9 11.80 11.80 - -
232Z25 7.55 16.20 3.24 2.70 2.16 1.80 1.80 25.75 10.14 16.38 16.38 -
Span 5.50 metres
172Z25 5.75 9.52 1.73 1.44 1.15 0.96 0.87 7.34 - 5.77 7.10 -
182Z15 3.57 4.95 0.90 0.75 0.60 0.50 0.45 6.27 - 3.77 4.81 -
182Z18 4.28 6.44 1.17 0.98 0.78 0.65 0.59 7.54 - 4.53 5.72 -
182Z20 4.76 7.54 1.37 1.14 0.91 0.76 0.69 8.58 - 5.03 6.33 -
182Z25 5.95 10.29 1.87 1.56 1.25 1.04 0.94 10.23 5.90 6.34 7.83 -
202Z15 3.92 5.67 1.03 0.83 0.69 0.57 0.52 8.47 - 5.22 5.74 -
202Z18 4.70 7.43 1.35 1.13 0.90 0.75 0.68 10.18 - 6.24 7.50 -
202Z20 5.23 8.64 1.57 1.31 1.05 0.87 0.79 11.22 5.62 6.92 8.38 -
202Z25 6.53 12.10 2.20 1.83 1.47 1.22 1.10 13.92 7.16 10.40 11.84 -
232Z15 4.53 6.93 1.26 1.05 0.84 0.70 0.63 13.04 - 7.00 7.00 -
232Z18 5.44 9.08 1.65 1.38 1.10 0.92 0.83 15.57 6.26 9.17 9.17 -
232Z20 6.04 10.62 1.93 1.61 1.29 1.07 0.97 17.22 7.16 10.73 10.73 -
232Z25 7.55 14.74 2.68 2.23 1.79 1.49 1.34 21.34 9.21 13.95 14.89 -
252Z15 4.76 7.43 1.35 1.13 0.80 0.75 0.68 15.79 - 7.49 7.49 -
252Z18 5.71 9.74 1.77 1.48 1.18 0.98 0.89 18.87 6.89 9.85 9.85 -
252Z20 6.34 11.44 2.08 1.73 1.39 1.16 1.04 20.85 7.95 11.55 11.55 -
252Z25 7.93 15.95 2.90 2.42 1.93 1.61 1.45 25.69 10.22 15.08 16.12 -

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 5 of 19

BUTT JOINT SYSTEM


Working Loads
Weight Total Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN [Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 6.00 metres
182Z20 4.76 6.90 1.15 0.96 0.77 0.64 0.58 7.02 4.38 5.68 -
182Z25 5.95 9.42 1.57 1.31 1.05 0.87 0.79 8.58 5.41 6.30 -
202Z18 4.70 6.78 1.13 0.94 0.75 0.63 0.57 8.52 4.86 6.24 -
202Z20 5.23 7.92 1.32 1.10 0.88 0.73 0.66 9.42 5.40 6.90 -
202Z25 6.53 11.10 1.85 1.54 1.23 1.03 0.93 11.64 8.52 10.06 -
232Z15 4.53 6.36 1.06 0.88 0.71 0.59 0.53 10.98 6.41 6.41 -
232Z18 5.44 8.34 1.39 1.16 0.93 0.77 0.70 13.14 8.08 8.41 -
232Z20 6.04 9.72 1.62 1.35 1.08 0.90 0.81 14.52 9.09 9.83 -
232Z25 7.55 13.5 2.25 1.88 1.50 1.25 1.13 17.94 11.53 13.49 -
BUTT SYSTEM

252Z15 4.76 6.78 1.13 0.94 0.75 0.63 0.57 13.26 6.86 6.86 -
252Z18 5.71 8.94 1.49 1.24 0.99 0.83 0.75 15.90 8.63 9.03 -
252Z20 6.34 10.5 1.75 1.46 1.17 0.97 0.88 17.52 9.69 10.58 -
252Z25 7.93 14.64 2.44 2.03 1.63 1.36 1.36 21.72 12.34 14.53 -
Span 6.50 metres
202Z20 5.23 7.28 1.12 0.93 0.75 0.62 0.56 8.00 4.76 5.60 -
202Z25 6.53 10.27 1.58 1.32 1.05 0.88 0.79 9.95 6.87 8.51 -
232Z15 4.53 5.85 0.90 0.75 0.60 0.50 0.45 9.36 5.46 5.92 -
232Z18 5.44 7.67 1.18 0.98 0.79 0.66 0.59 11.12 6.70 7.77 -
232Z20 6.04 8.97 1.38 1.15 0.92 0.77 0.69 12.29 7.54 8.99 -
232Z25 7.55 12.48 1.92 1.60 1.28 1.07 0.96 15.28 9.40 11.49 -
252Z18 5.71 8.26 1.27 1.06 0.85 0.71 0.64 13.46 7.05 8.34 -
252Z20 6.34 9.69 1.49 1.24 0.99 0.83 0.75 14.95 7.97 9.67 -
252Z25 7.93 13.52 2.08 1.73 1.39 1.16 1.04 18.46 9.93 12.40 -
262Z15 5.18 7.15 1.10 0.92 0.73 0.61 0.55 13.65 7.22 7.22 -
262Z18 6.22 9.36 1.44 1.20 0.96 0.80 0.72 10.79 9.47 9.47 -
262Z20 6.91 10.92 1.68 1.40 1.12 0.93 0.84 11.96 11.00 11.06 -
262Z25 8.63 15.28 2.35 1.96 1.57 1.31 1.18 22.30 14.20 15.49 -

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 6 of 19

BUTT JOINT SYSTEM


Working Loads
Weight Total Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN
[Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 7.00 metres
202Z25 6.53 9.52 1.36 1.13 0.91 0.76 0.68 8.61 5.62 7.13
232Z18 5.44 7.14 1.02 0.85 0.68 0.57 0.51 9.59 5.46 6.85
232Z20 6.04 8.33 1.19 0.99 0.79 0.66 0.60 10.64 6.06 7.70
232Z25 7.55 11.55 1.65 1.38 1.10 0.92 0.83 13.16 7.60 9.70
252Z18 5.71 7.63 1.09 0.91 0.73 0.61 0.55 11.62 5.78 7.31
252Z20 6.34 9.59 1.37 1.14 0.91 0.76 0.69 12.88 6.41 8.21
252Z25 7.93 12.53 1.79 1.49 1.19 0.99 0.90 15.89 8.04 10.38
262Z18 6.22 8.68 1.24 1.03 0.83 0.69 0.62 14.07 9.33 8.78
262Z20 6.91 10.15 1.45 1.21 0.97 0.81 0.73 15.54 9.92 10.27
262Z25 8.63 14.14 2.02 1.68 1.35 1.12 1.01 19.25 11.85 14.05
Span 7.50 metres
202Z25 6.53 8.85 1.18 0.98 0.79 0.66 0.59 7.43 5.25 5.88
232Z20 6.04 7.80 1.04 0.87 0.69 0.58 0.52 9.23 5.26 6.53
BUTT SYSTEM

232Z25 7.55 10.80 1.44 1.20 0.96 0.80 0.72 11.40 6.76 8.10
252Z20 6.34 8.40 1.12 0.93 0.75 0.62 0.56 11.18 5.84 6.92
252Z25 7.93 11.70 1.56 1.30 1.04 0.87 0.78 13.80 7.50 8.57
262Z18 6.22 8.10 1.08 0.90 0.72 0.60 0.54 12.23 6.97 8.20
262Z20 6.91 9.45 1.26 1.05 0.84 0.70 0.63 13.58 7.80 9.56
262Z25 8.63 13.2 1.76 1.47 1.17 0.98 0.88 16.73 9.76 12.31
Span 8.00 metres
202Z25 6.53 8.32 1.04 0.87 0.69 0.58 0.52 10.08 4.92 4.92 -
232Z25 7.55 10.16 1.27 1.06 0.85 0.71 0.64 12.24 6.33 6.71 -
252Z25 7.93 10.96 1.37 1.14 0.91 0.76 0.69 14.72 7.03 7.08 -
262Z20 6.91 8.88 1.11/ 0.93 0.74 0.62 0.56 21.20 6.44 8.30 -
262Z25 8.63 12.40 1.55 1.29 1.03 0.86 0.78 27.00 - 8.08 10.32
302Z20 7.61 9.92 1.24 1.03 0.83 0.69 0.62 30.53 - 8.28 10.03
302Z25 9.52 14.00 1.75 1.46 1.17 0.97 0.88 37.95 - 10.5 13.27
302Z30 11.42 18.48 2.31 1.93 1.54 1.28 1.16 45.18 - 12.99 16.03
Span 8.50 metres
232Z25 7.55 9.52 1.12 0.93 0.75 0.62 0.5 8.93 5.96 5.96 -
252Z25 7.93 10.29 1.21 1.01 0.81 0.67 0.61 10.8 6.62 6.62 -
262Z20 6.91 8.33 0.98 0.82 0.65 0.54 0.49 10.46 5.75 7.14 -
262Z25 8.63 11.65 1.37 1.14 0.91 0.76 0.69 13.09 7.60 10.75 -
302Z20 7.61 9.35 1.10 0.92 0.73 0.61 0.55 15.13 6.98 8.90 -
302Z25 9.52 13.18 1.55 1.29 1.03 0.86 0.78 18.87 8.95 11.41 -
302Z30 11.42 17.34 2.04 1.70 1.36 1.13 1.02 22.45 11.28 13.88

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 7 of 19

BUTT JOINT SYSTEM


Working Loads
Weight Total Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN
[Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 9.00 metres
232Z15 4.53 4.23 0.47 0.39 0.31 0.26 0.24 4.86 2.89 2.89 4.28
232Z18 5.44 5.58 0.62 0.52 0.41 0.35 0.31 5.85 3.83 3.83 5.61
232Z20 6.04 6.48 0.72 0.60 0.48 0.40 0.36 6.39 4.38 4.38 6.56
232Z25 7.55 9.00 1.00 0.83 0.67 0.56 0.50 7.92 5.63 5.63 8.45
252Z15 4.76 4.50 0.50 0.42 0.33 0.28 0.25 5.94 3.09 3.09 4.57
252Z18 5.71 5.94 0.66 0.55 0.44 0.37 0.33 7.02 4.21 4.21 6.02
252Z20 6.34 7.02 0.78 0.65 0.52 0.43 0.39 7.74 4.86 4.86 7.05
252Z25 7.93 9.72 1.08 0.90 0.72 0.60 0.54 9.63 6.25 6.25 9.13
262Z15 5.18 5.13 0.57 0.48 0.38 0.32 0.29 7.02 3.46 4.46 5.22
262Z18 6.22 6.75 0.75 0.63 0.50 0.42 0.38 8.46 4.59 5.44 6.83
262Z20 6.91 7.92 0.88 0.73 0.59 0.49 0.44 9.36 5.43 6.02 7.98
262Z25 8.63 10.98 1.22 1.02 0.81 0.68 0.61 11.61 7.18 7.51 11.19
BUTT SYSTEM

302Z20 7.61 8.82 0.98 0.82 0.65 0.54 0.49 13.50 5.96 7.72 8.92
302Z25 9.52 12.42 1.38 1.15 0.92 0.77 0.69 16.83 8.46 9.76 12.57
302Z30 11.42 16.38 1.82 1.52 1.21 1.01 0.91 20.03 10.65 12.0 16.61
342Z20 8.76 10.98 1.22 1.02 0.81 0.68 0.61 18.70 9.90 11.1 11.11
342Z25 10.87 15.39 1.71 1.43 1.14 0.95 0.86 23.19 12.95 15.5 15.59
342Z30 13.16 20.25 2.25 1.88 1.50 1.25 1.13 27.59 15.82 19.4 20.55
Span 9.50 metres
252Z15 4.76 4.28 0.45 0.38 0.30 0.28 0.23 5.32 2.93 2.93 4.33
252Z18 5.71 5.61 0.59 0.49 0.39 0.33 0.30 6.27 3.99 3.99 5.66
252Z20 6.34 6.65 0.70 0.58 0.47 0.39 0.35 7.03 4.61 4.61 6.33
252Z25 7.93 9.22 0.97 0.81 0.65 0.54 0.49 8.65 5.92 5.92 8.07
262Z15 5.18 4.85 0.51 0.43 0.34 0.28 0.26 6.37 3.28 3.87 4.94
262Z18 6.22 6.37 0.67 0.56 0.45 0.37 0.34 7.60 4.35 4.63 6.47
262Z20 6.91 7.51 0.79 0.66 0.53 0.44 0.40 8.36 5.15 5.15 7.57
262Z25 8.63 10.36 1.09 0.91 0.73 0.51 0.55 10.36 6.80 6.80 10.60
302Z18 6.85 7.13 0.75 0.63 0.50 0.42 0.38 10.93 4.67 5.89 7.19
302Z20 7.61 8.36 0.88 0.73 0.59 0.49 0.44 12.16 5.60 6.65 8.45
302Z25 9.52 11.78 1.24 1.03 0.83 0.69 0.62 15.01 8.01 8.45 11.91
302Z30 11.42 15.58 1.64 1.37 1.09 0.91 0.82 17.86 10.09 10.28 15.74
342Z20 8.76 10.36 1.09 0.91 0.73 0.61 0.55 17.71 8.65 10.47 10.52
342Z25 10.87 12.07 1.27 1.06 0.85 0.71 0.64 21.97 11.16 14.17 14.77
342Z30 13.14 19.19 2.02 1.68 1.35 1.12 1.01 26.14 13.77 17.19 19.48

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 8 of 19

BUTT JOINT SYSTEM


Working Loads
Weight Total Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN [Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 10.00 metres
342Z20 8.76 9.90 0.99 0.83 0.66 0.55 0.50 16.83 7.63 9.48 9.99
BUTT SYSTEM

34Z25 10.87 13.80 1.38 1.15 0.92 0.77 0.69 20.87 9.72 12.50 14.03
342Z30 13.16 18.20 1.82 1.52 1.21 1.01 0.91 24.83 12.14 15.14 18.51
Span 10.50 metres
342Z20 8.76 9.45 0.90 0.75 0.60 0.50 0.45 16.03 6.66 8.39 9.52
342Z25 10.87 13.13 1.25 1.04 0.83 0.69 0.63 19.88 8.87 10.91 13.36
342Z30 13.16 17.33 1.65 1.38 1.10 0.92 0.83 23.65 11.56 13.31 17.62
Span 11.00 metres
342Z20 8.76 11.22 1.02 0.85 0.68 0.57 0.51 15.30 5.87 7.47 9.09
342Z25 10.87 16.72 1.52 1.27 1.01 0.84 0.76 18.97 8.47 9.60 12.76
342Z30 13.16 21.89 1.99 1.66 1.33 1.11 1.00 22.57 11.04 11.81 16.82

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 9 of 19

SLEEVE JOINT SYSTEM


Working Loads
Weight Total Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN [Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 3.50 metres
122Z15 2.92 5.99 1.71 1.43 1.14 0.95 0.86 11.83 5.90
142Z15 3.21 7.35 2.10 1.75 1.40 1.17 1.05 17.23 7.29
142Z18 3.85 9.49 2.71 2.26 1.81 1.51 1.36 20.49 9.38
142Z20 4.29 10.96 3.13 2.62 2.09 1.74 1.57 22.63 10,84
142Z25 5.36 14.77 4.22 3.52 2.81 2.34 2.11 27.88 14.63
Span 4.00 metres
122Z15 2.92 5.24 1.31 1.09 0.87 0.73 0.66 9.06 5.16
142Z15 3.21 6.44 1.61 1.34 1.07 0.89 0.81 13.19 6.37
142Z18 3.85 8.28 2.07 1.73 1.38 1.15 1.04 15.69 8.21
142Z20 4.29 9.56 2.39 1.99 1.59 1.33 1.20 17.33 9.48
5.36 12.92 3.23 2.69 2.15 1.79 1.62 21.35 12.80
SLEEVE SYSTEM

142Z25
172Z15 3.45 7.44 1.86 1.55 1.24 1.03 0.93 19.86 9.19
172Z18 4.14 9.88 2.47 2.06 1.65 1.37 1.24 23.64 9.56
172Z20 4.60 11.28 2.82 2.35 1.88 1.57 1.41 26.13 11.12
172Z25 5.75 15.44 3.86 3.22 2.57 2.14 1.93 32.24 15.24
Span 4.50 metres
142Z15 3.21 5.72 1.27 1.06 0.85 0.71 0.64 10.42 5.67 5.67
142Z18 3.85 7.38 1.64 1.37 1.09 0.91 0.82 12.4 7.30 7.30
142Z20 4.29 8.51 1.89 1.58 1.26 1.05 0.95 13.69 8.43 8.43
142Z25 5.36 11.48 2.55 2.13 1.70 1.42 1.28 16.87 11.38 11.38
172Z15 3.45 6.61 1.47 1.23 0.98 0.82 0.74 15.69 6.53 6.53
172Z18 4.14 8.60 1.91 1.59 1.27 1.06 0.96 18.68 8.50 8.50
172Z20 4.60 10.03 2.23 1.86 1.49 1.24 1.12 20.64 9.89 9.89
172Z25 5.75 13.73 3.05 2.54 2.03 1.69 1.53 25.47 13.55 13.55
182Z15 3.57 7.16 1.59 1.33 1.06 0.88 0.80 18.09 7.08 7.08
182Z18 4.28 9.32 2.07 1.73 1.38 1.15 1.04 21.54 9.22 9.22
182Z20 4.76 10.85 2.41 2.00 1.61 1.34 1.21 23.81 10.72 10.72
182Z25 5.95 14.85 3.30 2.75 2.20 1.83 1.65 29.4 14.69 14.69
202Z15 3.92 8.19 1.82 1.52 1.21 1.01 0.91 24.4 8.10 8.10
202Z18 4.70 10.26 2.28 1.90 1.52 1,27 1.14 29.08 10,58 10,58
202Z20 5.23 12,47 2.77 2.31 1.85 1.54 1.39 32.16 12.33 12.33
202Z25 6.53 17.01 3.78 3.15 2.52 2.10 1.89 39.74 17.21 17.21

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 10 of 19

SLEEVE JOINT SYSTEM


Working Loads
Weight Total Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN [Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 5.00 metres
172Z15 3.45 5.95 1.19 0.99 0.79 0.66 0.60 12.71 5.88 5.88
172Z18 4.14 7.75 1.55 1.29 1.03 0.86 0.78 15.13 7.65 7.65
172Z20 4.60 9.00 1.80 1.50 1.20 1.00 0.90 16.72 8.90 8.90
172Z25 5.75 12.35 2.47 2.06 1.65 1.37 1.24 20.63 12.20 12.20
182Z15 3.57 6.45 1.29 1.08 0.86 0.72 0.65 14.65 6.37 6.37
182Z18 4.28 8.40 1.68 1.40 1.12 0.93 0.84 17.45 8.30 8.30
182Z20 4.76 9.05 1.81 1.51 1.21 1.00 0.91 19.29 9.65 9.65
182Z25 5.95 13.40 2.68 2.23 1.79 1.49 1.34 23.81 13.23 13.23
202Z15 3.92 7.35 1.47 1.23 0.98 0.82 0.74 19.76 7.29 7.29
202Z18 4.70 9.65 1.93 1.61 1.29 1.07 0.97 23.55 9.53 9.53
202Z20 5.23 11.25 2.25 1.88 1.50 1.25 1.13 26.05 11.10 11.10
SLEEVE SYSTEM

202Z25 6.53 15.30 3.06 2.55 2.04 1.70 1.53 32.19 15.50 15.50
232Z15 4.53 9.00 1.80 1.50 1.20 1.00 0.90 30.31 8.89 8.89
232Z18 5.44 11.80 2.36 1.97 1.57 1.31 1.18 36.15 11.65 11.65
232Z20 6.04 13.75 2.75 2.29 1.83 1.53 1.38 40.01 13.62 13.62
232Z25 7.55 19.10 3.82 3.18 2.55 2.12 1.91 49.51 18.90 18.90
Span 5.50 metres
182Z15 3.57 5.83 1.06 0.88 0.71 0.59 0.53 12.11 5.79 5.79
182Z18 4.28 7.65 1.39 1.16 0.93 0.77 0.70 14.42 7.54 7.54
182Z20 4.76 8.86 1.61 1.34 1.07 0.89 0.81 15.94 8.77 8.77
182Z25 5.95 12.16 2.21 1.84 1.47 1.23 1.11 19.68 12.02 12.02
202Z15 3.92 6.71 1.22 1.02 0.81 0.68 0.61 16.33 6.63 6.63
202Z18 4.70 8.75 1.59 1.33 1.06 0.88 0.80 19.47 8.66 8.66
202Z20 5.23 10.23 1.86 1.55 1.24 1.03 0.93 21.53 10.10 10.10
202Z25 6.53 13.92 2.53 2.11 1.68 1.41 1.27 26.6 14.08 14.08
232Z15 4.53 8.14 1.48 1.23 0.99 0.82 0.74 25.05 8.08 8.08
232Z18 5.44 10.73 1.95 1.63 1.30 1.08 0.98 29.88 10.60 10.60
232Z20 6.04 12.49 2.27 1.89 1.51 1.26 1.14 33.06 12.38 12.38
232Z25 7.55 17.38 3.16 2.63 2.11 1.76 1.58 40.92 17.17 17.17
25215 4.76 8.75 1.59 1.33 1.06 0.88 0.80 30.25 8.66 8.66
252Z18 5.71 11.50 2.09 1.74 1.39 1.16 1.05 36.10 11.39 11.39
252Z20 6.34 13.48 2.45 2.04 1.63 1.36 1.23 39.96 13.34 13.34
252Z25 7.93 18.81 3.42 2.85 2.28 1.90 1.71 49.47 18.62 18.62

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 11 of 19

SLEEVE JOINT SYSTEM


Working Loads
Weight Total Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN [Purlin Centers in mms] Deflection [Metal cladding] No of Antisag

1000 1200 1500 1800 2000 Span/180 0 1 2 3


Span 6.00 metres
182Z18 4.28 6.96 1.16 0.97 0.77 0.64 0.58 12.12 6.91 6.91
182Z20 4.76 8.16 1.36 1.13 0.91 0.76 0,68 13.40 8.04 8.04
182Z25 5.95 11.16 1.86 1.55 1.24 1.03 0.93 16.53 11.02 11.02
202Z15 3.92 6.12 1.02 0.85 0.68 0.57 0.51 13.72 6.08 6.08
202Z18 4.70 8.04 1.34 1.12 0.89 0.74 0.67 16.35 7.94 7.94
202Z20 5.23 9.36 1.56 1.30 1.04 0.87 0.78 18.09 9.25 9.25
202Z25 6.53 12.78 2.13 1.78 1.42 1.18 1.07 22.35 12.92 12.92
232Z15 4.53 7.50 1.25 1.04 0.83 0.69 0.63 21.04 7.41 7.41
232Z18 5.44 9.84 1.64 1.37 1.09 0.91 0.82 25.10 9.70 9.70
232Z20 6.04 11.46 1.91 1.59 1.27 1.06 0.96 27.78 11.35 11.35
SLEEVE SYSTEM

232Z25 7.55 15.90 2.65 2.21 1.77 1.47 1.33 34.38 15.74 15.74
252Z15 4.76 7.98 1.33 1.11 0.89 0.74 0.67 25.42 7.94 7.94
252Z18 5.71 10.56 1.76 1.47 1.17 0.98 0.88 30.33 10.44 10.44
252Z20 6.34 12.36 2.06 1.72 1.37 1.14 1.03 33.57 12.23 12.23
232Z25 7.93 17.22 2.87 2.39 1.91 1.59 1.44 41.57 17.06 17.06
Span 6.50 metres
202Z18 4.70 7.41 1.14 0.95 0.76 0.63 0.57 13.94 7.32 7.32
202Z20 5.23 8.65 1.33 1.11 0.89 0.74 0.67 15.41 8.54 8.54
202Z25 6.53 11.77 1.81 1.51 1.21 1.00 0.91 19.05 11.92 11.92
232Z15 4.53 6.89 1.06 0.88 0.71 0.59 0.53 17.93 6.84 6.84
232Z18 5.44 9.04 1.39 1.16 0.93 0.77 0.70 21.39 8.96 8.96
232Z20 6.04 10.60 1.63 1.36 1.09 0.91 0.82 23.67 10.47 10.47
232Z25 7.55 14.69 2.26 1.88 1.51 1.26 1.13 29.30 14.53 14.53
252Z15 4.76 7.41 1.14 0.95 0.76 0.63 0.57 21.66 7.33 7.33
25218 5.71 9.75 1.50 1.25 1.00 0.83 0.75 25.84 9.64 9.64
252Z20 6.34 11.38 1.75 1.46 1.17 0.97 0.88 28.61 11.28 11.28
252Z25 7.93 15.93 2.45 2.04 1.63 1.36 1.23 35.42 15.74 15.74
262Z15 5.18 8.45 1.30 1.08 0.87 0.72 0.65 26.08 8.32 8.32
262Z18 6.22 11.05 1.70 1.42 1.13 0.94 0.85 31.13 10,89 10,89
262Z20 6.91 12.94 1.99 1.66 1.33 1.11 1.00 34.47 12.72 12.72
262Z25 8.63 18.07 2.78 2.32 1.85 1.54 1.39 42.71 17.79 17.79

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 12 of 19

SLEEVE JOINT SYSTEM


Working Loads
Weight Total
Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN
[Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 7.00 metres
202Z20 5.23 8.05 1.15 0.96 0.77 0.64 0.58 13.29 7.93 7.93
202Z25 6.53 10.92 1.56 1.30 1.04 0.87 0.78 16.42 11.97 11.97
232Z18 5.44 8.40 1.20 1.00 0.80 0.67 0.60 18.44 8.32 8.32
232Z20 6.04 9.80 1.40 1.17 0.93 0,78 0.70 20.41 9.72 9.72
232Z25 7.55 13.65 1.95 1.63 1.30 1.09 0.98 25.26 13.50 13.50
252Z18 5.71 9.03 1.29 1.08 0.86 0.72 0.65 22.28 8.95 8.95
25Z020 6.34 10.57 1.51 1.26 1.00 0.84 0.76 24.67 10.48 10.48
252Z25 7.93 14.77 2.11 1.76 1.41 1.17 1.06 30.54 14.62 14.62
262Z15 5.18 7.77 1.11 0.93 0.74 0.62 0.56 22.48 7.73 7.73
262Z18 6.22 10.22 1.46 1.22 0.97 0.81 0.73 26.84 10.12 10.12
262Z20 6.91 11.97 1.71 1.43 1.14 0.95 0.86 29.72 11.81 11.81
262Z25 8.63 16.8 2.40 2.00 1.60 1.33 1.20 36.83 16.52 16.52
Span 7.50 metres
SLEEVE SYSTEM

202Z20 5.23 7.50 1.00 0.83 0.67 0.56 0.50 11.58 7.40 7.40
202Z25 6.53 10.2 1.36 1.13 0.91 0.76 0.68 14.3 10.33 10.33
232Z18 5.44 7.88 1.05 0.88 0.70 0.58 0.53 16.06 7.77 7.77
232Z20 6.04 9.15 1.22 1.02 0.81 0.68 0.61 17.78 9.08 9.08
232Z25 7.55 12.8 1.70 1.42 1.13 0.94 0.85 22.00 12.59 12.59
252Z18 5.71 8.40 1.12 0.93 0.75 0.62 0.56 19.41 8.35 8.35
252Z20 6.34 9.90 1.32 1.10 0.88 0.73 0.66 21.49 9.78 9.78
252Z25 7.93 13.8 1.84 1.53 1.23 1.02 0.92 26.60 13.64 13.64
262Z18 6.22 9.60 1.28 1.07 0.85 0.71 0.64 23.38 9.44 9.44
262Z20 6.91 11.18 1.49 1.24 0.99 0.83 0.75 25.89 11.92 11.92
262Z25 8.63 15.68 2.09 1.74 1.39 1.16 1.05 32.08 15.42 15.42
Span 8.00 metres
232Z20 6.04 8.64 1.08 0.90 0.72 0.60 0.54 15.63 8.51 8.51
232Z25 7.55 11.92 1.49 1.24 0.99 0.83 0.75 19.34 11.81 11.81
252Z20 6.34 9.28 1.16 0.97 0.77 0.64 0.58 18.88 9.17 9.17
252Z25 7.93 12.96 1.62 1.35 1.08 0.90 0.81 23.38 12.79 12.79
262Z18 6.22 8.96 1.12 0.93 0.75 0.62 0.56 20.55 8.85 8.85
262Z20 6.91 10.48 1.31 1.09 0.87 0.73 0.66 22.70 10.34 10.34
262Z25 8.63 14.64 1.83 1.53 1.22 1.02 0.92 28.19 14.46 14.46
302Z18 6.85 10.00 1.25 1.04 0.83 0.69 0.63 29.66 9.87 9.87
302Z20 7.61 11.68 1.46 1,22 0.97 0.81 0.73 32.85 11.60 11.60
302Z25 9.52 16.48 2.06 1.72 1.37 1.14 1.03 40.74 16.33 16.33
302Z30 11.42 21.76 2.72 2.27 1.81 1.36 1.51 48.48 21.56 21.56

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 13 of 19

SLEEVE JOINT SYSTEM


Working Loads
Weight Total Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN [Purlin Centers in mms] Deflection [Metal cladding] No of Antisag

1000 1200 1500 1800 2000 Span/180 0 1 2 3


Span 8.50 metres
232Z25 7.55 11.22 1.32 1.10 0.88 0.73 0.66 17.13 11.11 11.11
252Z20 6.34 8.67 1.02 0.85 0.68 0.57 0.51 16.73 8.63 8.63
252Z25 7.93 12.16 1.43 1.19 0.95 0.79 0.72 20.71 12.04 12.04
262Z18 6.22 8.50 1.00 0.83 0.67 0.56 0.50 18.2 8.33 8.33
262Z20 6.91 9.86 1.16 0.97 0.77 0.64 0.58 20.15 9.73 9.73
262Z25 8.63 13.86 1.63 1.36 1.09 0.91 0.82 24.97 13.61 13.61
302Z18 6.85 9.35 1.10 0.92 0.73 0.61 0.55 26.27 9.29 9.29
302Z20 7.61 11.05 1.30 1.08 0.87 0.72 0.65 29.1 10.92 10.92
302Z25 9.52 15.56 1.83 1.53 1.22 1.02 0.92 36.09 15.36 15.36
302Z30 11.42 20.49 2.41 2.00 1.61 1.34 1.21 42.95 20.29 20.29
Span 9.00 metres
232Z25 7.55 10.62 1.18 0.98 0.79 0.66 0.59 15.28 10.49 10.4
SLEEVE SYSTEM

252Z25 7.93 11.52 1.28 1.07 0.85 0.71 0.64 18.47 11.37 11.37
262Z20 6.91 9.36 1.04 0.87 0.69 0.58 0.52 17.98 9.19 9.19
262Z25 8.63 13.05 1.45 1.21 0.97 0.81 0.73 22.28 12.85 12.8
302Z20 7.61 10.44 1.16 0.97 0.77 0.64 0.58 25.96 10.31 10.31
302Z25 9.52 14.67 1.63 1.36 1.09 0.91 0.82 32.19 14.51 14.51
302Z30 11.42 19.35 2.15 1.79 1.43 1.19 1.08 38.31 19.16 19.16
342Z20 8.76 12.96 1.44 1.20 0.96 0.80 0.72 35.23 12.79 12.79
342Z25 10.87 18.18 2.02 1.68 1.35 1.12 1.01 43.69 17.94 17.94
342Z30 13.16 23.94 2.66 2.22 1.77 1.48 1.33 51.98 23.62 23.62
Span 9.50 metres
252Z25 7.93 10.93 1.15 0.96 0.77 0.64 0.58 16.58 10.78 10.78 10.78
262Z25 8.63 12.35 1.30 1.08 0.87 0.72 0.65 20.0 12.17 12.1 12.17
302Z20 7.61 9.88 1.04 0.87 0.69 0.58 0.52 23.29 9.77 9.77 9.77
302Z25 9.52 13.87 1.46 1.22 0.97 0.81 0.73 28.89 13.75 13.7 13.75
302Z30 11.42 18.34 1.93 1.61 1.29 1.07 0.97 34.38 18.15 18.15 18.15
342Z20 8.76 12.26 1.29 1.08 0.86 0.72 0.65 33.38 12.11 12.11 12.11
342Z25 10.87 17.20 1.81 1.51 1.21 1.00 0.91 41.39 17.00 17.00 17.00
342Z30 13.16 22.70 2.39 1.99 1.59 1.33 1.20 49.25 22.39 22.39 22.39
Span 10.00 metres
342Z20 8.76 11.70 1.17 0.98 0.78 0.65 0.59 31.71 11.50 11.50
342Z25 10.87 16.40 1.64 1.37 1.09 0.91 0.82 39.32 16.15 16.15
342Z30 13.16 21.60 2.16 1.80 1.44 1.20 1.08 46.78 21.26 21.26

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 14 of 19

SLEEVE JOINT SYSTEM


Working Loads
Weight Total
Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN
[Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
SLEEVE SYSTEM

1000 1200 1500 1800 2000 Span/180 0 1 2 3


Span 10.50 metres
342Z20 8.76 11.13 1.06 0.88 0.71 0.59 0.53 30.20 10.96 10.96
342Z25 10.87 15.54 1.48 1.23 0.99 0.82 0.74 37.45 15.37 15.37
342Z30 13.16 20.58 1.96 1.63 1.31 1.09 0.98 44.56 20.26 20.26
Span 11.00 metres
342Z25 10.87 14.63 1.33 1.11 0.89 0.74 0.67 3 5.75 14.68 14.68
342Z30 13.16 19.58 1.78 1.48 1.19 0.99 0.89 42.53 19.33 19.33

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 15 of 19

OVERLAPJOINT SYSTEM
Working Loads
Weight Total
Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN
[Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 5.00 metres
172Z15 3.45 8.90 1.78 1.48 1.19 0.99 0.89 14.80 8.55
172Z18 4.14 11.6 2.32 1.93 1.55 1.29 1.16 17.00 10.51
172Z20 4.60 13.5 2.70 2.25 1.80 1.50 1.35 19.00 11.94
172Z25 5.75 18.5 3.70 3.08 2.47 2.06 1.85 23.15 14.73
182Z15 3.57 9,65 1.93 1.61 1.29 1.07 0.97 17.05 9.45
182Z18 4.28 12.55 2.51 2.09 1.67 1.39 1.26 19.95 11.65
182Z20 4.76 14.60 2.92 2.43 1.95 1.62 1.46 21.95 13.02
182Z25 5.95 20.05 4.01 3.34 2.67 2.23 2.01 27.00 16.08
202Z15 3.92 11.05 2.21 1.84 1.47 1.23 1.11 22.90 10.88
202Z18 4.7 14.45 2.89 2.41 1.93 1.61 1.45 27.00 13.64
202Z20 5.23 16.85 3.37 2.81 2.25 1.87 1.69 29.70 15.30
202Z25 6.53 23.50 4.70 3.92 3.13 2.61 2.35 36.10 19.49
Span 5.50 metres
172Z15 3.45 8.14 1.48 1.23 0.99 0.82 0.74 12.27 8.00
OVERLAP SYSTEM

172Z18 4.14 10.56 1.92 1.60 1.28 1.07 0.96 14.3 9.58
172Z20 4.60 12.27 2.23 1.86 1.49 1.24 1.12 15.73 10.88
172Z25 5.75 16.83 3.06 2.55 2.04 1.70 1.53 19.20 13.42
182Z15 3.57 8.80 1.60 1.33 1.07 0.89 0.80 14.03 8.61
182Z18 4.28 11.44 2.08 1.73 1.39 1.16 1.04 16.56 10,62
182Z20 4.76 13.31 2.42 2.02 1.61 1.34 1.21 18.15 11.87
182Z25 5.95 18.26 3.32 2.77 2.21 1.84 1.66 22.11 14.65
202Z15 3.92 10.07 1.83 1.53 1.22 1.02 0.92 19.03 9.91
202Z18 4.70 13.15 2.39 1.99 1.59 1.33 1.20 22.39 12.44
202Z20 5.23 15.35 2.79 2.33 1.86 1.55 1.40 24.42 13.95
202Z25 6.53 21.40 3.89 3.24 2.59 2.16 1.95 29.76 17.65
Span 6.00 metres
182Z15 3.57 8.04 1.34 1.12 0.89 0.74 0.67 11.76 7.10
182Z18 4.28 10.44 1.74 1.45 1.16 0.97 0.87 13.86 9.68
182Z20 4.76 12.12 2.02 1.68 1.35 1.12 1.01 15.12 10.82
182Z25 5.95 16.56 2.76 2.30 1.84 1.53 1.38 18.42 13.27
202Z15 3.92 9.18 1.53 1,28 1.02 0.85 0.77 15.78 9.04
202Z18 4.70 11.94 1.99 1.66 1.33 1.11 1.00 18.48 11.33
202Z20 5.23 13.98 2.33 1.94 1.55 1.29 1.17 20.40 12.72
202Z25 6.53 19.50 3.25 2.71 2.17 1.81 1.63 24.90 16.19
232Z15 4.53 11.22 1.87 1.56 1.25 1.04 0.94 24.30 10.71
232Z18 5.44 14.70 2.45 2.04 1.63 1.36 1.23 28.32 14.10
232Z20 6.04 17.16 2.86 2.38 1.91 1.59 1.43 31.32 16.20
232Z25 7.55 23.82 3.97 3.31 2.65 2.21 1.99 38.28 20.84
Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 16 of 19

OVERLAP JOINT SYSTEM


Working Loads
Weight Total
Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN
[Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 6.50 metres
182Z15 3.57 7.41 1.14 0.95 0.76 0.63 0.57 10.01 7.27
182Z18 4.28 9.69 1.49 1.24 0.99 0.83 0.75 11.70 8.96
182Z20 4.76 11.25 1.73 1.44 1.15 0.96 0.87 12.87 10.01
182Z25 5.95 15.41 2.37 1.98 1.58 1.32 1.19 15.73 12.36
202Z15 3.92 8.52 1.31 1.09 0.87 0.73 0.66 13.46 8.37
202Z18 4.70 11.12 1.71 1.43 1.14 0.95 0.86 15.80 10.49
202Z20 5.23 12.94 1.99 1.66 1.33 1.11 1.00 17.36 11.77
202Z25 6.53 18.07 2.78 2.32 1.85 1.54 1.39 21.19 14.98
232Z15 4.53 10.34 1.59 1.33 1.06 0.88 0.80 20.61 9.91
232Z18 5.44 13.00 2.00 1.67 1.33 1.11 1.00 24.12 13.10
232Z20 6.04 15.86 2.44 2.03 1.63 1.36 1.22 26.78 15.00
OVERLAP SYSTEM

232Z25 7.55 21.19 3.26 2.72 2.17 1.81 1.63 32.57 19.28
Span 7.00 metres
182Z18 4.28 8.96 1.28 1.07 0.85 0.71 0.64 10.01 8.28
182Z20 4.76 10.36 1.48 1.23 0.99 0.82 0.74 11.06 9.25
182Z25 5.95 13.86 1.98 1.65 1.32 1.10 0.99 13.51 10.43
202Z15 3.92 7.84 1.12 0.93 0.75 0.62 0.56 11.62 7.73
202Z18 4.70 10.29 1.47 1.23 0.98 0.81 0.74 13.58 9.69
202Z20 5.23 11.97 1.71 1.43 1.14 0.95 0.86 14.91 10.87
202Z25 6.53 16.66 2.38 1.98 1.59 1.32 1.19 18.2 13.85
232Z15 4.53 9.59 1.37 1.14 0.91 0.76 0.69 17.64 9.16
232Z18 5.44 12.53 1.79 1.49 1.19 0.99 0.90 20.72 12.11
232Z20 6.04 14.63 2.09 1.74 1.39 1.16 1.05 22.68 13.85
232Z25 7.55 20.37 2.91 2.43 1.94 1.62 1.46 28.07 17.82
252Z15 4.76 10.29 1.47 1.23 0.98 0.82 0.74 21.56 9.78
252Z18 5.71 13.51 1.93 1.61 1.29 1.07 0.97 25.34 13.34
252Z20 6.34 15.82 2.26 1.88 1.51 1.26 1.13 27.10 15.39
252Z25 7.93 22.05 3.15 2.63 2.10 1.75 1.58 33.53 19.80
262Z15 5.18 11.62 1.66 1.38 1.11 0.92 0.83 25.76 10.95
262Z18 6.22 15.26 2.18 1.82 1.45 1.21 1.09 30.10 14.52
262Z20 6.91 17.78 2.54 2.12 1.69 1.41 1.27 33.46 17.20
262Z25 8.63 24.92 3.56 2.97 2.37 1.98 1.78 40.46 22.72

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 17 of 19

OVERLAP JOINT SYSTEM


Working Loads
Weight Total
Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN
[Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 7.50 metres
182Z18 4.28 8.33 1.11 0.93 0.74 0.62 0.56 8.93 7.74
182Z20 4.76 9.60 1.28 1.07 0.85 0.71 0.64 9.90 8.66
182Z25 5.95 11.93 1.59 1.33 1.06 0.88 0.80 12.08 10.69
202Z18 4.70 9.60 1.28 1.07 0.85 0.71 0.64 12.08 9.07
202Z20 5.23 11.18 1.49 1.24 0.99 0.83 0.75 13.35 10.17
202Z25 6.53 15.60 2.08 1.73 1.39 1.16 1.04 16.35 12.96
232Z18 5.44 11.78 1.57 1.31 1.05 0.87 0.79 18.68 11.33
232Z20 6.04 13.73 1.83 1.53 1.22 1.02 0.92 20.48 12.96
232Z25 7.55 19.05 2.54 2.12 1.69 1.41 1.27 25.13 16.67
OVERLAP SYSTEM

252Z18 5.71 12.60 1.68 1.40 1.12 0.93 0.84 22.50 12.48
252Z20 6.34 14.78 1.97 1.64 1.31 1.09 0.99 24.83 14.39
252Z25 7.93 20.63 2.75 2.29 1.83 1.53 1.38 30.30 18.52
262Z18 6.22 14.25 1.90 1.58 1.27 1.06 0.95 27.15 13.59
262Z20 6.91 16.65 2.22 1.85 1.48 1.23 1.11 29.70 16.10
262Z25 8.63 23.33 3.11 2.59 2.07 1.73 1.56 36.68 21.25
Span 8.00 metres
202Z18 4.70 8.96 1.12 0.93 0.75 0.62 0.56 10.56 8.46
202Z20 5.23 10.48 1.31 1.09 0.87 0.73 0.66 11.60 9.50
202Z25 6.53 14.56 1.82 1.52 1.21 1.01 0.91 14.32 12.10
232Z18 5.44 10.96 1.37 1.14 0.91 0.76 0.69 16.32 10.58
232Z20 6.04 12.80 1.60 1.33 1.07 0.89 0.80 17.92 12.10
232Z25 7.55 17.76 2.22 1.85 1.48 1.23 1.11 22.16 15.56
252Z18 5.71 11.76 1.47 1.23 0.98 0.82 0.74 19.60 11.65
252Z20 6.34 13.84 1.73 1.44 1.15 0.96 0.87 21.76 13.44
252Z25 7.93 19.28 2.41 2.00 1.61 1.34 1.21 26.72 17.29
262Z18 6.22 13.28 1.66 1.38 1.11 0.92 0.83 23.84 12.97
262Z20 6.91 15.52 1.94 1.62 1.29 1.08 0.97 26.08 15.02
262Z25 8.63 21.76 2.72 2.27 1.81 1.51 1.36 32.16 19.84

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 18 of 19

OVERLAP JOINT SYSTEM


Working Loads
Weight Total
Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN
[Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 8.50 metres
202Z18 4.70 8.50 1.00 0.83 0.67 0.56 0.50 9.35 8.00
202Z20 5.23 9.61 1.13 0.94 0.75 0.63 0.57 10.37 8.96
202Z25 6.53 13.77 1.62 1.35 1.08 0.90 0.81 12.58 11.41
232Z15 4.53 7.91 0.93 0.78 0.61 0.52 0.47 12.24 7.55
232Z18 5.44 10.37 1.22 1.02 0.81 0.68 0.61 14.37 9.98
232Z20 6.04 12.07 1.42 1.18 0.95 0.79 0.71 15.9 11.41
232Z25 7.55 16.75 1.97 1.64 1.31 1.09 0.99 19.47 14.68
252Z15 4.76 8.42 0.99 0.83 0.66 0.55 0.50 14.71 8.05
252Z18 5.71 11.14 1.31 1.09 0.87 0.73 0.66 17.34 10.99
252Z20 6.34 13.00 1.53 1.28 1.02 0.85 0.77 19.21 12.67
252Z25 7.93 18.19 2.14 1.78 1.43 1.19 1.07 23.46 16.31
262Z15 5.18 9.61 1.13 0.94 0.75 0.63 0.57 17.85 9.03
262Z18 6.22 12.58 1.48 1.23 0.99 0.82 0.74 21.00 11.97
OVERLAP SYSTEM

262Z20 6.91 14.71 1.73 1.44 1.15 0.96 0.87 22.95 14.17
262Z25 8.63 20.49 2.41 2.00 1.61 1.34 1.21 28.39 18.68
302Z18 6.85 14.03 1.65 1.38 1.10 0.92 0.83 30.77 13.70
302Z20 7.61 16.49 1.94 1.62 1.29 1.08 0.97 34.00 15.65
302Z25 9.52 23.21 2.73 2.28 1.82 1.52 1.37 41.4 22.06
Span 9.00 metres
202Z25 6.53 10.26 1.14 0.95 0.76 0.63 0.57 11.22 10.31
232Z15 4.53 8.28 0.92 0.77 0.61 0.51 0.46 10.92 7.94
232Z18 5.44 9.72 1.08 0.90 0.72 0.60 0.54 12.81 9.44
232Z20 6.04 11.34 1.26 1.05 0.84 0.70 0.63 14.18 10.80
232Z25 7.55 15.75 1.75 1.46 1.17 0.97 0.88 17.36 13.90
252Z18 5.71 10.44 1.16 0.97 0.77 0.64 0.58 15.47 10.40
252Z20 6.34 12.24 1.36 1.13 0.91 0.76 0.68 17.13 12.00
252Z25 7.93 17.10 1.90 1.58 1.27 1.06 0.95 20.93 15.43
262Z15 5.18 9.00 1.00 0.83 0.67 0.56 0.50 15.92 8.54
262Z18 6.22 11.79 1.31 1.09 0.87 0.73 0.66 18.73 11.32
262Z20 6.91 13.77 1.53 1.28 1.02 0.85 0.77 20.47 13.41
262Z25 8.63 19.35 2.15 1.79 1.43 1.19 1.08 25.32 17.71
302Z20 7.61 15.48 1.72 1.43 1.15 0.96 0.86 30.33 14.58
302Z25 9.52 21.78 2.42 2.02 1.61 1.34 1.21 36.92 22.55
342Z20 8.76 19.17 2.13 1.78 1.42 1.18 1.07 44.04 19.57
342Z25 10.87 27.00 3.00 2.50 2.00 1.67 1.50 54.61 27.49
342Z30 13.16 35.55 3.95 3.29 2.63 2.19 1.98 64.98 34.22

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .
Cold Formed Profile Z—Purlin
Technical Data Sheet & Load Tables Page 19 of 19

OVERLAP JOINT SYSTEM


Working Loads
Weight Total
Allowable downward loads in Kn/m2 Total UDL Kn Total Uplifting Loads in KN
Section Kg/m UDL KN
[Purlin Centers in mms] Deflection [Metal cladding] No of Antisag
1000 1200 1500 1800 2000 Span/180 0 1 2 3
Span 9.50 metres
232Z18 5.44 9.22 0.97 0.81 0.65 0.54 0.49 7.49 8.92
232Z20 6.04 10.74 1.13 0.94 0.75 0.63 0.57 8.30 10.20
232Z25 7.55 15.01 1.58 1.32 1.05 0.88 0.79 10.07 13.12
252Z18 5.71 9.88 1.04 0.87 0.69 0.58 0.52 11.50 9.82
252Z20 6.34 11.69 1.23 1.03 0.82 0.68 0.62 12.72 11.32
252Z25 7.93 16.15 1.70 1.42 1.13 0.94 0.85 15.58 14.57
262Z15 5.18 8.55 0.90 0.75 0.60 0.50 0.45 11.77 8.06
262Z18 6.22 11.21 1.18 0.98 0.79 0.66 0.59 13.88 10.69
262Z20 6.91 13.11 1.38 1.15 0.92 0.77 0.69 15.38 12.66
262Z25 8.63 18.34 1.93 1.61 1.29 1.07 0.97 18.78 16.72
302Z18 6.85 12.54 1.32 1.10 0.88 0.73 0.66 14.29 11.50
302Z20 7.61 14.73 1.55 1.29 1.03 0.86 0.78 16.81 13.76
302Z25 9.52 20.71 2.18 1.82 1.45 1.21 1.09 18.37 19.70
OVERLAP SYSTEM

342Z20 8.76 18.24 1.92 1.60 1.28 1.07 0.96 41.72 18.39
342Z25 10.87 25.56 2.69 2.24 1.79 1.49 1.35 51.74 24.91
342Z30 13.16 33.73 3.55 2.96 2.37 1.97 1.78 61.56 31.43
Span 10.00 metres
232Z20 6.04 10.20 1.02 0.85 0.68 0.57 0.51 7.49 9.65
232Z25 7.55 13.00 1.30 1.08 0.87 0.72 0.65 9.09 12.42
252Z20 6.34 11.0 1.10 0.92 0,73 0.61 0.55 11.48 10.73
252Z25 7.93 13.8 1.38 1.15 0.92 0.77 0.69 14.06 13.80
262Z18 6.22 10.60 1.06 0.88 0.71 0.59 0.53 12.53 10.12
262Z20 6.91 12.40 1.24 1.03 0.83 0.69 0.62 13.88 11.99
262Z25 8.63 16.80 1.68 1.40 1.12 0.93 0.84 16.95 15.83
302Z18 6.85 11.20 1.12 0.93 0.75 0.62 0.56 12.90 10.88
302Z20 7.61 13.30 1.33 1.11 0.89 0.74 0.67 15.17 13.03
302Z25 9.52 19.60 1.96 1.63 1.31 1.09 0.98 16.58 18.66
342Z20 8.76 17.30 1.73 1.44 1.15 0.96 0.87 37.75 16.60
342Z25 10.87 24.20 2.42 2.02 1.61 1.34 1.21 46.81 22.85
342Z30 13.16 31.90 3.19 2.66 2.13 1.77 1.60 55.70 29.76
Span 10.50 metres
342Z20 8.76 16.49 1.57 1.31 1.05 0.87 0.79 37.75 14.90
342Z25 10.87 23.103 2.20 1.83 1.47 1.22 1.10 46.81 21.80
342Z30 13.16 30.45 2.90 2.42 1.93 1.61 1.45 55.70 28.40
Span 11.00 metres
342Z20 8.76 15.73 1.43 1.19 0.95 0.79 0.72 36.03 14.19
342Z25 10.87 22.003 2.00 1.67 1.33 1.11 1.00 44.68 20.74
342Z30 13.16 28.93 2.63 2.19 1.75 1.46 1.32 53.16 27.06

Rev 06 19/02/2017
T: +971 6 533 8449
E: [email protected]

The Roof & Cladding Company Website: TigerPROFILES.com

Information contained here was, at the time of publishing, accurate and true to the best of our knowledge. We reserve the right to make any changes for continuous improvement .

You might also like