3) What Aramco Engineering Standard for safety requirement for coating application?
Ans. SAES-H- 102
8) Which standard to be follow for surface cleanliness for commercial blast cleaning?
Ans. SA2 / SSPC-SP6 / NACE No. 3
10) Which standard to be follow for surface cleanliness for near white metal blast cleaning?
Ans. SA 2.5 /SSPC SP10 / NACE No. 2
11) How many percent of blast clean for near white metal blast cleaning?
Ans. Cleaning has a limit of staining of not more than 5%.
12) Which standard to be follow for surface cleanliness for white metal blast cleaning?
Ans. SA 3 /SSPC SP5 / NACE No.1
13.) How many percent of blast clean for white metal blast cleaning?
Ans. Removes all visible oil, grease, dust, dirt, mill scale, rust, coating, oxides, corrosion
products and any other foreign matter on the surface.
14) Which standard to be follow for surface cleanliness for Brush-off blast cleaning?
Ans. SA 1 /SSPC SP7 / NACE No.4
15.) How many percent of blast clean for Brush-off blast cleaning?
Ans. Removes all visible oil, grease, dust, dirt, as well as loose mill scale but tightly
adherent mill scale rust, and the coating may remain.
16) What does the discontinuity mean?
Ans. Holiday
17) In what sequence the internal blasting will be done for the tank?
Ans. From top to bottom
26) Can new galvanized will be coated with APCS for more protection?
Ans. Yes
29) What is the 45:1 ratio for the airless spray pump?
Ans. The inlet to outlet pump ratio
34) Solvent and paints shall not be applied over substrate if temperature is greater than?
Ans. 80 ºC
35) Solvent shall not be flushed into the containers that are hotter than?
Ans.50 ºC
37) Coating pull back in after paint cure happen on the sharp edges?
Ans. True
38) When surface contamination in steel like salt spray dust and other debris what failure will
occur?
Ans. Lack of adhesion
39) During internal blasting of a crude oil tank what surface preparation is required prior to start
blasting?
Ans. Solvent cleaning
40) Wet sponge holiday volts for the internal tank
Ans. 67.5 volts
41) Before filling the water inside the tank what test has to be done?
Ans. Holiday test with repair/water
42) Paint over buried SS pipe?
Ans. Halide liquid free coating, liquid coating recommended by RSA?
43) Profile range given in msds, pds, apcs specification?
44) During water jetting blasting which device will protect from slippery of nozzle?
Ans. Whip Lock
45) The trigger safety catch shall be engaged whenever the airless gun is left unattended?
Ans. Airless Spray
2. The following coating defect may be seen immediately after a thick film of epoxy coating
sprayed
a) checking and cracking
b) sagging
c) mud cracking and chalking
d) blistering
3. Anode, cathode, metallic pathway and electrolyte are elements of corrosion cells
a) True
b) False
5. After applying paint on the surface, paint got wetted by raining, as a painting inspector what will
you do?
a) recoat painting without removing existing coating
b) wait for water dry
c) Re-blast and re application
d) abrade and remove affected area by sanding
10. Saudi Aramco Engineering standard which describe safety rules of abrasive blasting and coating
a) SAES-H-002
b) SAES-H-002v
c) SAES-H-102
d) SAES-H-001
23. The distance from nozzle to blotter paper when performed the compressed air quality test shall be
a) 30-40 cm
b) 45-60 cm
c) 60-70 cm
d) 55-65 cm
26. If an airless spray pump ratio 35:1 fluid pressure 2800 required for inlet pressure
a) 100 psi
b) 90 psi
c) 80 psi
d) 60 psi
31. Name the gauge used for measuring pressure at the blast nozzle
a) hypodermic needle pressure gauge
b) relief pressure gauge
c) air pressure gauge
d) all of above
32. The air receivers that are used as a surge tank between compressor and blasting pot shall be hydro
tested at a pressure of at least
a) 150 psi
b) 125 psi
c) 175 psi
d) 250 psi
33. Coating materials used for construction site must be cover and the temporary storage period shall
not exceed
a) 10 days
b) 05 days
c) 14 days
d) 07 days
34. The use of recycled abrasives is permitted only in shops provided that the recycling
system is
a) inspected and approved by coating inspector
b) approved by project manager
c) Evaluated and approved by csd
d) approved by project inspection department
35. After blasting the external coating surface chloride content shall not exceed
a) 30 mg/m²
b) 15 mg/m²
c) 20 mg/m²
d) 40 mg/m²
36. After blasting the internal coating surface chloride content shall not exceed
a) 30 mg/m²
b) 15 mg/m²
c) 20 mg/m²
d) 40 mg/m²
37. In case of brush application, the maximum brush size shall be used
a) 75 mm
b) 100 mm
c) 125 mm
d) 150 mm
38. what defect could occur if the profile is higher than specified
a) blister
b) mill scale
c) pinpoint rusting
d) cause paint adhesion
40. The temperature of which moisture begins to condensate on a steel surface is called
a) relative humidity
b) dew point
c) maximum surface temperature
d) minimum surface temperature
41. What standard explains how to measure dry film thickness with magnetic gages?
a) sspc-pa1
b) sspc-pa2
c) sspc-pa3
d) sspc-pa4
42. what documents will describe the health and safety of hazard of a coating material?
a) the job specification
b) material safety data sheets
c) sspc safety specification
d) osha standard
44. Standard test method for measuring adhesion by the tape test.
a) astm d 3359
b) astm d 3363
c) astm d 3350
d) astm d 3747
45. wet sponge holiday detector is checked with-----dc volts for dft not exceeding-------
a) 90v/ 600microns
b) 69.5v/ 500microns
c) 67.5v/ 500microns
d) 67.5v/ 1000microns
46. what DFT will get, when applied 150µ wft with 50% of volume solid?
a) 85micron
b) 90micron
c) 100micron
d) 75micron DFT= WFT x VS% 150 x 50 7500 = 75microns
100 100 100
47. If the given DFT is 400 microns and volume of solids is 100% what is the WFT
a) 450micron
b) 500micron
e) 400micron WFT= DFT x 100 400 x 100 = 40000 = 400microns
VS% 100 100
c) 350micron
48. What would be the volume of solid by percentage can be obtained on 375 microns WFT & 120
microns DFT?
f) 85micron
g) 90micron
h) 100micron
i) 75micron VS%= DFT x 100 120 x 100 12000 = 32% VS
WFT 375 375
50. what is the minimum nozzle air pressure required for abrasive blasting?
a) 90 psi
b) 75 psi
c) 100 psi
d) 80 psi
51. What would you do if you receive coatings that have exceeded their shelf life?
a) use the coating if it’s the appearance is normal
b) use the material if there is no hard setting of pigment
c) shall be set aside and must not be used unless written authorization to the
contrary is given by the consulting services department.
d) contact the coating manufacturer for information about the usability of the coatings.
52. what is the correct formula for computing the wet film thickness (wft), needed to achieve the
specified dry film thickness (dft) of a coating?
a) wft = dft x percent solids by volume
b) wft = dft x 0.50
c) wft = dft x percent of solids by wt.
d) dft x vs
53. Which of the following characteristics of paint is easily tested in the field?
a) viscosity
b) dry opacity
c) identification of the solvent in the paint
d) identification of the paint resin
54. Windy condition can cause which of the following paint defects?
a) wrinkling
b) sagging
c) fish eyes
d) dry spray
55. Grounding wire for blasting and coating equipment shall be awg?
a) 6 or larger
b) 8 or larger
c) 4 or larger
d) 5 or larger
59. For Internal FBE coating, the weld cap or internal root protrusion shall not be more than
a) 5mm
b) 10mm
c) 2.5mm
d) 1.5mm
62. What is the DC volt range for holiday testing of FBE coating?
a) 1000-1500 dc
b) 2000-5000 dc
c) 1500-2000 dc
d) 2500-4000 dc
68. What is the speed of high voltage holiday detector while performed testing?
a) 90cm/sec
b) 80cm/sec
c) 30cm/sec
d) 75cm/sec
69. While repair on touch up of galvanized steel surface, what generic paint used as primer?
a) zinc phosphate epoxy
b) zinc silicate
c) zinc rich epoxy
d) mastic epoxy
71. For blasting nozzle size of 1/2”, what shall be the minimum cfm of compressor??
a) 800cfm
b) 412cfm
c) 550cfm
d) 620cfm
Abrasive cleanliness
SSPC-SP 7
74. Which is not surface preparation method?
Heating
Thoroughly
75. Buried stainless steel lines shall be externally coated with FBE, halide free liquid
coating, apcs-113a, or viscoelastic coating apcs-113c depending on operating temperature
When the steel surface is at least 3°c above the dew point
The blasting hose shall be the static dissipating type with external couplings
78. Unit for adhesion pull off test as per ASTM 4541 result
Whip Lock
Low cost, Easy to clean, Complex structures, Less moving parts and contaminants
The time between the first coat and the next coat
DFT measurement
APCS 19a
APCS 19b
86. Brush off blasting standard?
SSPC SP-7
88.When the blaster is about to faint which device helps him from stopping the blasting?
Deadman switch
89. The minimum temperature difference between metal temperature and the dew point?
3 degrees
Pigment
Dial Micrometer
250 mm
92. When steel surface is contaminated by water of salts, the failure the coating occurs in
the form of bubbles shape is called?
Osmatic blisters
1.) What does PH value shows?
Ans. Acid and Alkaline nature
2.) FBE powder coating?
3.) Solvent and paints shall not be applied over substrate if temperature are
Greater than ……?
Ans. 80 ºC
4.) Brush off blast cleaning?
Ans. SSPC SP7
5.) What is the Swedish Standard for near white metal blast cleaning?
SA 2.5 / Very Thorough Blast Cleaning
6.)