Controller CAN Nodes
Controller CAN Nodes
Control system
Overview The controller CAN nodes cover all aspects of DC power system monitoring: AC Mains Voltage, current, frequency and energy consumption Battery symmetry, current and fuse monitoring Alarm outputs and control inputs Load branch current and fuse Climate control of fan/filter cabinets Generator control/fuel tank level measurements
www.eltekvalere.com
Models
Battery Monitor Its compact design and easy connection to the control system through the CAN bus, makes it perfect for both co-located and remote battery banks. Battery temperature is measured by the embedded temperature probe no external sensor and wiring required. The unit has 4 voltage measurement inputs used for battery symmetry monitoring based on midpoint or block measurements. Furthermore the battery monitor has inputs for monitoring one battery shunt and battery breaker.
Load Monitor Individual distribution breaker monitoring can be done with the Load Monitor. The unit has the possibility to connect up to 8 current shunts and monitor 8 fuses individually. It can be used for both positive and negative distributions. However it is important for the current measurements that the shunts are connected to the same pole as the system reference of the control system. CAN repeater and CAN Power device can be used in cases where this is not fulfilled.
I/O Monitors The I/O Monitors are used to expand the standard monitor and alarm capabilities of the controller. Each I/O monitor module has 6 configurable inputs for fuse sense and feeding external signals into the control system, and 6 configurable relay outputs for connecting external alarms. The I/O Monitor Type3 is designed for doing tank level measurements. Some of its inputs are prepared to do high resolution current and voltage measurements. In addition, special inputs and outputs are added for climate control in outdoor cabinets in the I/O Monitor (Outdoor) and Type3.
CAN Power All nodes are powered by the distributed power supplied on the CAN bus by the Smartpack and Smartpack2 basic controllers. If the CAN bus needs to be isolated or additional CAN bus power is need, the CAN power module can be added to supplement the available power. The CAN power module is mandatory if any CAN control units are to be connected to a Compack controller.
www.eltekvalere.com
2(4)
242100.CAN.DS3 v4
Models
AC Mains Monitor With inputs for measuring voltage and current on up to 3 phases of the AC mains of a system, the mains availability, quality and consumed energy are easily monitored. The energy log keeps track of consumption per phase and total, and stores it by hour, day and week. The log is available for download through the WebPower interface to the system. The current range are set by selecting the sensor, 0 50 A up to 0 600 A are available. Due to software restraints the energy log supports only up to 200A. There is also a configurable data log that by default stores AC frequency together with current and voltage for each measured phase and a time stamp. The log interval is configurable and the log has space for the last 5000 samples. The 5 configurable digital inputs can be used for monitoring SPDs and other external equipment
AC Mains Monitor
3 mains current sensor ports (for LEM HAL or equivalent) o o o o Sensor reference Signal Sensor supply Sensor supply + Signal NO/NC, Pull Up/Dn, Diode matrix CSCP Protocol Max 300 mA 402093.009 Energy log (non-volatile memory) of each phase and total (max 200A per phase) o Last 52 hours o Last 52 days o Last 52 weeks Data log with up to 5000 samples with timestamp (default: VAC, IAC and frequency) 176 x 97.6 x 42.8 mm (WxDxH) (6.93 x 3.84 x 1.69) 0V 0 4 Vp-p (45 - 65 Hz) -15 V 15 V 0-300 Vrms(45-65 Hz) (0 60 V)
3 mains voltage inputs o 5 configurable digital inputs o o 1 RS 485 Communication port for customer connection Max. CAN Power consumption
Start 1 1 11 17 33 49 81 97
End 14 10 14 30 46 62 94 110
Number of nodes 14 10 4 14 14 14 14 14
3(4)
Dimensions
242100.CAN.DS3 v4
6 configurable relay outputs: normally activated/deactivated o Dry/Form C, Max 1A/60W/75V o Dry/Form C, Max 8A/300W/75V No1-4(1,3), No1-6(2) No5-6(1,3)
Outdoor cabinet specific ports: temp, fan control/monitoring o 2xTemp sensor inputs (-40-100C with 0.14C res.)(1,3) o 2xFan speed inputs (0-5V or pulse sense 1-10 p/r)(1,3) o 2xFan speed control outputs (0-10V, max -10/+20mA) (1,3) Max. CAN Power consumption SW Part number Functionality 402088.009
(1,2,3)
Load Monitor
Inputs Accuracy based on resolution (calibrated) Functionality 8x Configurable (Fuse failure) 8x Current sense Current (200A): +/- 1A Fuse failure o NO, NC or Diode Matrix Current sense o 50mV or 60mV shunt 402087.009 120mA 155.5 x 70.5 x 31 mm (6.12 x 2.78 x 1.22 ) Dimensions (WxDxH)
Data logging (non-volatile memory) o 10000 time stamped logs o 4 user selectable data points o Default: 2x Temp. 2x Fan Speed 155.5 x 85.2 x 31 mm (1,3) (6.1 x 3.4 x 1.2 ) 135.9 x 59 x 25.6 mm (2) (5.4 x 2.3 x 1.2 )
Applicable Standards
Electrical safety IEC 60950-1 UL 60950-1 CSA C22.2 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 /A1 IEC 61000-6-4 ETSI EN 300 386 v1.3.3 FCC Part 15B Subpart 109 2002/95/EC (RoHS) & 2002/96/EC (WEEE) ETS 300 019-2-1 Class 1.2 ETS 300 019-2-2 Class 2.3 ETS 300 019-2-3 Class 3.2
Specifications are subject to change without notice 241120.200.DS3 v4
EMC
Part numbers
Part no.
Environment
Description
Battery Monitor Load Monitor CAN Power I/O Monitor (Outdoor) I/O Monitor Type 2 I/O Monitor Type 3 AC Mains Monitor
www.eltekvalere.com
Eltek Valere Grterudv. 8, PB 2340 Strms, 3003 Drammen, Norway Phone: +47 32 20 32 00 Fax: +47 32 20 32 10