NA To Sls en 1991-1-2 2021

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

SRI LANKA STANDARD

NA TO SLS EN 1991-1-2:2021
UDC 614.84

NATIONAL ANNEX TO
SLS EN 1991-1-2:2021,
ACTIONS ON STRUCTURES –
PART 1-2: GENERAL ACTIONS - ACTIONS
ON STRUCTURES EXPOSED TO FIRE

SRI LANKA STANDARDS INSTITUTION

Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.
Licensed by SLSI to Urban development Authority
2022-06-28
Single-user licence only, copying and networking prohibited.
NATIONAL ANNEX TO SLS EN 1991-1-2:2021,
ACTIONS ON STRUCTURES -PART 1-2: GENERAL ACTIONS - ACTIONS ON
STRUCTURES EXPOSED TO FIRE

NA to SLS EN 1991-1-2:2021

Gr. 3

Copyright Reserved
SRI LANKA STANDARDS INSTITUTION
No.17, Victoria Place
Elvitigala Mawatha
Colombo 8
SRI LANKA.

Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.
Sri Lanka Standards are subject to
periodical revision in order to
accommodate the progress made by
industry. Suggestions for improvement
will be recorded and brought to the notice
of the Committees to which the revisions
are entrusted.

This Standard does not purport to include


all the necessary provisions of a contract

© SLSI 2021

All right reserved. Unless otherwise specified, no part of this publication may be reproduced
or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm, without permission in writing from the SLSI.

Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.
Committee responsible for this National Annex

The preparation of this National Annex was entrusted by Committee SC35/WG/12, upon which the
following bodies were represented:

Eng. S A Karunarathne (Chairman) -The Society of Structural Engineers, Sri Lanka


Eng.(Dr) K.Baskaran - University of Moratuwa, Department of Civil Engineering
Eng. (Dr) Ruwan Appuhamy - University of Ruhuna, Department of Civil and Environmental Engineering
Mr. J. Kannangara -Fire Service Department
Eng. W M D N Ranasinghe -Personal Capacity (former Deputy Chief Secretary- Provincial
Engineering Organization– Western Province)
Eng. G T R de Silva - The Institution of Engineers, Sri Lanka
Eng.(Mrs.) T.J.Jayasundara -Central Engineering Consultancy Bureau
Eng. M A R M A Jabbar -Road Development Authority
Eng.(Ms.) T A E I Siriwardhane - Sri Lanka Standards Institution
(Secretary )

Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.
Licensed by SLSI to Urban development Authority
2022-06-28
Single-user licence only, copying and networking prohibited.
NA to SLS EN 1991-1-2:2021

NATIONAL ANNEX (INFORMATIVE) TO SLS EN 1991-1-2:2015,


ACTIONS ON STRUCTURES -PART 1-2: GENERAL ACTIONS - ACTIONS ON
STRUCTURES EXPOSED TO FIRE

INTRODUCTION

This National Annex has been prepared based on EN 1991-1-2:2002 by the Working group on
the development of the National Annexes to Euro Codes (SC35/WG/12). It is to be used in
conjunction with SLS EN 1991-1-2:2015, along with any further revision, amendment or
corrigendum thereto.
This National Annex was approved by the Sectoral Committee on Building and Construction
Materials and was authorized for adoption and publication as a Sri Lanka National annex by
the Council of the Sri Lanka Standards Institution on 2021-07-29.
In the preparation of this standard the assistance derived from the publication of the European
Committee for Standardization (CEN) and British Standards Institution (BSI) is gratefully
acknowledged.

NA.1 SCOPE

This National Annex gives:

a) the Sri Lanka decisions for the Nationally Determined Parameters described in the
following sub clauses of SLS EN 1991-1-2: 2015:
- 2.4 (4)
- 3.1 (10)
- 3.3.1.2 (1)
- 3.3.1.3 (1)
- 3.3.2 (2)
- 4.2.2 (2)
- 4.3.1 (2)
b) the Sri Lanka decisions on the status of SLS EN 1991-1-2:2015 informative annexes.

NA.2 NATIONALLY DETERMINED PARAMETERS

NA.2.1 Temperature analysis


[SLS EN 1991-1-2:2015, 2.4 (4)]

SLS EN 1991-1-2 recommends that temperature analysis is performed using a


nominal temperature-time curve or a fire model.

When performing temperature analysis in terms of the nominal temperature-time


curve, the period of time within which to make the temperature analysis is
specified in CIDA Publication No. CIDA/DEV/14 (3 rd Edition, June 2018), Fire
Regulations or latest revisions
When performing temperature analysis using fire models, no limited periods of
fire resistance are specified. Fire models used should be soundly based, robust
and suitable for the given fire design scenario.
3

Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.
NA to SLS EN 1991-1-2:2021

NA.2.2 Thermal actions for temperature analysis


[SLS EN 1991-1-2:2015, 3.1 (10)]

The use of the nominal temperature-time curves specified in SLS EN 1991-1-2:2015,


3.2 is permitted as appropriate to the application.
NOTE The nominal time-temperature relationships are taken from the furnace
heating curves described in BS EN 1363-1 and BS EN 1363-2.
The use of the natural fire models specified in SLS EN 1991-1-2:2015, 3.3 is
permitted.
NA.2.3 Simplified fire models - Compartment fires
[SLS EN 1991-1-2:2015, 3.3.1.2 (1)]

The heating conditions for determining the gas temperature of compartment fires may
be calculated in accordance with SLS EN 1991-1-2:2015, Annex A or Annex B but
only in conjunction with the complementary information in PD 6688-1-2:2007, 3.2 and
Chapter 3 Structural Fire Precautions of CIDA Publication No. CIDA/DEV/14 (3 rd
Edition, June 2018), Fire Regulations or latest revisions.

NA.2.4 Simplified fire models - Localised fires


[SLS EN 1991-1-2:2015, 3.3.1.3 (1)]

The heating conditions for local fires may be calculated in accordance with PD 6688-1-
2:2007, 4.1. The use of SLS EN 1991-1-2:2015, Annex C is not permitted.

NA.2.5 Advanced fire models


[SLS EN 1991-1-2:2002, 3.3.2 (2)]

The "one-zone, two-zone", "multi-zone" and "computational fluid dynamic" advanced


fire models described in SLS EN 1991-1-2:2015, 3.3.2 (2) may be used.

NA.2.6 Simultaneity of actions -Additional actions


[SLS EN 1991-1-2:2002, 4.2.2 (2)]

No additional actions need to be considered.

NA.2.7 Combination rules for actions [SLS EN 1991-1-2:2002, 4.3.1 (2)]

The representative value of the variable action Q 1 should be taken as the frequent
value ψ 1.1 Q1

Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.
NA to SLS EN 1991-1-2:2021

NA.3 DECISIONS ON THE STATUS OF THE INFORMATIVE ANNEXES

NA.3.1 Parametric temperature time curves


[SLS EN 1991-1-2:2015, Annex A]
This annex may be used but only in conjunction with the complementary information
in PD 6688-1-2:2007, 3.1.1.
NA.3.2 Thermal actions for external members
[SLS EN 1991-1-2:2015, Annex B]
This annex may be used but only in conjunction with the complementary information
in PD 6688-1-2:2007, 3.1.2 and Chapter 3 Structural Fire Precautions of CIDA
Publication No. CIDA/DEV/14 (3 rd Edition, June 2018), Fire Regulations or latest
revisions (33to 61 pages)
NA.3.3 Localised fires [SLS EN 1991-1-2:2015, Annex C]
This annex may not be used.
PD 7974-1:2019, 8.1 to 8.7 should be used as a replacement.
NA.3.4 Advanced fire models
[S L S EN 1991-1-2:2002, Annex D]
This annex may be used.

NA.3.5 Fire load densities


[SLS EN 1991-1-2: 2015, Annex E]
This annex may not be used.
PD 6688-1-2:2007, Annex A should be used as a replacement.
NA.3.6 Equivalent time of fire exposure [SLS EN 1991-1-2:2015, Annex F]
This annex may not be used.
PD 6688-1-2:2007, Annex B should be used as a replacement.

NA.3.7 Configuration factor


[SLS EN 1991-1-2:2015, Annex G]
This annex may be used.

NA.4 REFERENCES TO NON-CONTRADICTORY COMPLEMENTARY


INFORMATION
The following is a list of references that contain non-contradictory complementary
information for use with SLS EN 1991-1-2:2015.
• PD 6688-1
• ISO 16730‐1
• PD 7974‐1:2019 Application of Fire Safety Engineering
Principles to the Design of Buildings Part 1 Initiation and
development of fire within the enclosure of origin (Sub‐system 1)
• All other PD 7974: 2019 series part 2, 3, etc. up to 7.
• CIDA Fire Regulation No. CIDA/DEV/14 (3 rd Edition ,June 2018)

Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.
Licensed by SLSI to Urban development Authority
2022-06-28
Single-user licence only, copying and networking prohibited.
Licensed by SLSI to Urban development Authority
2022-06-28
Single-user licence only, copying and networking prohibited.
Licensed by SLSI to Urban development Authority
2022-06-28
Single-user licence only, copying and networking prohibited.

You might also like