Open Psychrometric Chart in Oc

The document is a psychrometric chart published by ASHRAE showing temperature and humidity measurements at sea level atmospheric pressure. It displays lines of constant enthalpy, humidity ratio, and sensible heat ratio. The chart allows users to determine thermal properties of air at different temperature and moisture levels.

Uploaded by

Yidenek Nigussie
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
167 views1 page

Open Psychrometric Chart in Oc

The document is a psychrometric chart published by ASHRAE showing temperature and humidity measurements at sea level atmospheric pressure. It displays lines of constant enthalpy, humidity ratio, and sensible heat ratio. The chart allows users to determine thermal properties of air at different temperature and moisture levels.

Uploaded by

Yidenek Nigussie
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ASHRAE Psychrometric Chart No.

1
Normal Temperature
Barometric Pressure: 101.325 kPa

1992 American Society of Heating, 0.36


Refrigerating and Air-Conditioning Engineers, Inc.
30
Sea Level
100 28 0.40

0.9
4
30
Σ 1.0 1.0 –Σ
0.8 1.5
120
10.0 0.7 2.0 – 5.0
0.6 4.0 – 2.0 26
Sensible heat DH – Σ 90
0.5 —————– = ——S – 4.0 30
. 0 Total heat DHT – 2.0 0.0
5 0.4 1.0 0.45

3
–0
24

0.
1.0

.5
4.0

0.2
– 0.2

0.1
0 80

0.9
110
DHS
DHT

r
ai 22

2.0
y

2 vo
0.50

3.0
dr

2.5
lum
am

e
Enthalpy Dh gr
—————— = —— ilo 70 25

cub
Humidity ratio D e rk 20
sp 0.55
Total heat

ic m
le
Sensible heat
—————– = ——

jou 100

eter
ilo 25

%
)k 18

per
wet
b

90
(h 60 ulb 0.60

0.9
py tem

0
kilo
al per

%
th atu gra

80
En re °
C
m
°C 16 0.65
re
dry

%
a tu
50 20

70
er
air

p 90 0.70
m
te 14
n
tio % 0.75
ra 60

0.8
tu 20

8
40 Sa 0.80
% 12
Humidity ratio ( ) grams moisture per kilogram dry air

50 0.85
15 80 0.90
% 10 0.95
30 40

0.8
6
15 1.0

10 30% 8
20 70

0.8
4
10
6
5 20%

0.8
5

2
y 4
umidit
lative h
0 10% re 60

0.8
0

0.7
2

8
0 10 20 30 40 50
927

Dry bulb temperature °C


APPENDIX 1

Prepared by Center for Applied Thermodynamic Studies, University of Idaho.

FIGURE A–31
Psychrometric chart at 1 atm total pressure.
Reprinted from American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA.