6 3 5 4 2
This power supply has been designed specifically internal temperature is reached. The power supply
for use in teaching physics, chemistry and other will turn itself on again, when it has cooled off.
science subjects. The power supply can provide
both direct current (DC) and alternating current (AC).
The power supply can provide both types of electri-
cal power at the same time, and they can be adjus- Important !
ted independently of one another. Separate displays Never connect two power supply outlets in paral-
are provided for DC and AC output. lel. This applies whether the outlets belong to the
same apparatus or to separate units.
Safety
The power supply is of the switched mode type, and
Operation
it adheres to the EN-61558-1 standard. The connec-
The power supply is connected to the power outlet
tion jacks are safety-type 4 mm banana plug con-
230 VAC, 50 Hz (115 V 50/60 Hz) using the power
nectors and are well-suited for use with students.
cord which is provided.
The connectors will also accept leads with ordinary
The apparatus must be connected to a power outlet
banana plugs. The apparatus is CE marked and
with ground.
approved.
A power cord with ground is provided with the ap- The control panel is divided into two sections:
paratus. The apparatus must be connected to a
The DC-controls are to the left, the AC-controls are
power outlet with ground.
to the right. Each section operates independently of
Under extreme conditions, which will rarely occur
the other.
under normal use (high temperature combined with
high loading for a long period of time), the power The numbered items on the control panel (see illu-
supply will automatically shut down when a given stration) correspond to the following functions:
®
A/S Søren Frederiksen, Ølgod Tel. +45 7524 4966 [email protected]
Viaduktvej 35 · DK-6870 Ølgod Fax +45 7524 6282 www.frederiksen.eu
1) On/off switch with lamp Technical data:
2) Connection jacks for AC 230 V version:
3) Connection jacks for DC Input voltage: 200 - 242 volts, 50 Hz
4) Regulating knob for AC Input current: 1.4 amperes
5) Regulating knob for the DC current limiter. Fuses: 2 ea. 3.15 AT
If a current limit is to be set, proceed as follows: (no. 4090.15)
Adjust the voltage adjustment knob (6) to the Power consumption: 320 watts
desired voltage. Short circuit the DC output con- 115 V version:
nectors with a test lead. Use the current adjust-
Input voltage: 100 - 121 volts, 50/60 Hz
ment knob (5) to adjust the maximum current
Input current: 2.8 amperes
desired. Remove the short circuit again.
Fuses: 2 ea. 6.3 AT
The current is now prevented from exceeding this
(no. 4090.09)
value, regardless of the position of the voltage
Power consumption: 320 watts
regulating knob (6).
The maximum current which can be supplied is
shown on the following graph: DC:
Output voltage
continuously adjustable: 0-24 volts
output current (0-12 volts): 0-10 amperes
output current (12-24 volts): 0-10/6 amperes