In Vitrocell Co2 Incubator Product Brochure
In Vitrocell Co2 Incubator Product Brochure
In Vitrocell Co2 Incubator Product Brochure
CO2 Incubators
About NuAire. For more than 45 years, NuAire has been committed to bringing you the highest-quality, most dependable
laboratory products on the market. We are universally recognized as one of the world’s leading providers of reliable equipment
for the most demanding environments, including Biological Safety Cabinets, CO2 Incubators,Laminar Air Flow workstations,
Ultra Low Temperature Freezers, Centrifuges,Animal Transfer Stations, Pharmacy Compounding Isolators, Polypropylene Fume
Hoods, Polypropylene Casework, and a variety of complementary products and systems. You can depend on our products to
feature brilliant but practical design, and we pay keen attention to every step of the production process, from fabrication to
assembly to thorough testing. As a NuAire customer, you can also rely on us for outstanding value and dependable service -
the cornerstones of our reputation as the leading provider of laboratory products internationally.
In-VitroCell ES (Energy Saver) CO2 Incubators are designed to provide a reliable controlled in-vitro environment for
optimum tissue cell culture growth as well as the storage and preservation of gametes and animal tissue cell cultures intended
for research at or near body temperature. In-VitroCell CO2 Incubators provides accurate and precise control of humidity,
temperature, CO2, and sterility.
3
4
NuTouch
The NuTouch Electronic Control System (ECS) is a color 127 x 178 mm (5 x 7-inch) touchscreen designed for
high user adoption. Designed after smart-phone technology, NuTouch creates a unique product experience
providing an easy method to control, monitor, and notify. Help screens offer a step-by-step guide to assist in
procedures such as running a sterilization cycle. User activated help pop-up descriptions are available if an
item or icon is unclear. For example, pressing the text “CO2” on the main screen provides the description “This
control setting specifies the measured current value of Carbon Dioxide (CO2) inside the Incubator Chamber.“
outrage
• Temperature Recovery Mode - Activated in the
event of continuous chamber temperature loss,
increased power is routed to heaters until chamber
temperature returns to normal
System Settings menu allows access to CO2 Service Settings allows service personnel to calibrate
incubator information such as performance, system parameters and diagnose service difficulties.
service, system information, and more.
5
Rounded interior corners in the growth chamber
promote more thorough cleaning by eliminating
tight crevasses found in 90-degree corners.
6
Constant Contamination Control
Contamination-Free Design
Construction
The growth chamber is constructed of 16 gauge, type 304L polished stainless steel using a crevice-free design.
The growth chamber walls are completely smooth with rounded corners which allow more complete contact
between the chamber surface and cleaning solutions than a typical 90-degree corner. Shelving, supports and
guide rails are easily removable and can be autoclaved or left in the chamber during a sterilization cycle.
7
Closed Loop HEPA Filtration
[E]
Airflow pattern within the incubator, and sensor bay continuously sampling the growth environment.
[A] HEPA Filter [B] Air Pump [C] Sensor Bay [D] Water Pan [E] Air Inlet Tube
The Closed Loop HEPA filtration system includes filters outside the growth chamber, convenient to service
or replace, with minimal change to the growth environment.
8
Optional Surfaces
Copper Surfaces
Copper Option
Add copper surfaces to the incubator growth chamber and
shelving to reduce bacteria and minimize potential incubator
contamination.
Shelves and water pans fabricated from copper are available as options.
9
Temperature Uniformity and Recovery
Because your samples matter, In-VitroCell CO2 Incubators from NuAire offer the fastest recovery
times in the industry.
SET POINT
NU-5810 Temperature Recovery After 30 Sec. Door Opening
37.2
37.1
37.0 0.12 °C
36.9 PER MINUTE
Temperature, C°
36.8 (Average)
Open Return to 37° C
36.7
36.6
Closed
Set Point 15 Min. TEMPERATURE
36.5 After Door Closed
36.4
36.3
36.2
36.1
36.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Time, Minutes
Temp. Chamber Temperature Uniformity (Direct Heat): ± 0.3°C @ 37°C Temperature Accuracy: ± 0.1% Temperature Recovery: 0.12°C/Min. Ave.
Chamber Temperature Uniformity (Water Jacketed): ± 0.2°C @ 37°C Temperature Accuracy: ± 0.1% Temperature Recovery: 0.12°C/Min. Ave.
10
Temperature and CO2 Control
CO2 Range: 0.1 to 20% Accuracy: ± 0.1% Recovery: Up to 5% -0.50% / +0.20% in 5 Minutes Average
11
O2 and Relative Humidity Control
including the brain, eyes, liver, heart, kidneys, and more. O2 RANGE O2 ACCURACY O2 RECOVERY
Featured on O2 Control models only.
Humidity Control
Relative humidity levels up to 90% are achieved in the growth SET POINT
chamber through the use of a 3-liter reservoir external to the 90 % +5 %
chamber. The chamber air is routed through the water vapor
SET POINT SET POINT 90 %
saturated the air in an evaporate box to add humidity when ± 5%
the RH sensor indicates more humidity is needed to meet 25 MINUTES
set point.
AMBIENT -3 % (On Average)
12
CO2 Incubator Selection
Selection Guide
Chamber Temperature
Model CO2 Sensor Sterilization Cycles RH (Humidity) Control O2 Control
Volume Control
5.65 ft 3 _ _
NU-5700 Direct Heat Dual Wave IR Water Pan, Convection
(160 L)
5.65 ft 3 _
NU-5710 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified Water Pan, Convection
(160 L)
5.65 ft 3 Reservoir, _
NU-5720 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified
(160 L) Sensor Controlled
5.65 ft 3 Sensor
NU-5731 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified Water Pan, Convection
(160 L) (0.5 - 21%)
5.65 ft 3 Reservoir, Sensor
NU-5741 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified
(160 L) Sensor Controlled (0.5 - 21%)
7.06 ft 3 _ _
NU-5800 Direct Heat Dual Wave IR Water Pan, Convection
(200 L)
7.06 ft 3 _
NU-5810 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified Water Pan, Convection
(200 L)
7.06 ft 3 Reservoir, _
NU-5820 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified
(200 L) Sensor Controlled
7.06 ft 3 Sensor
NU-5831 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified Water Pan, Convection
(200 L) (0.5 - 21%)
7.06 ft 3 Reservoir, Sensor
NU-5841 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified
(200 L) Sensor Controlled (0.5 - 21%)
5.65 ft 3 _ _
NU-8600 Water Jacket Dual Wave IR Water Pan, Convection
(160 L)
5.65 ft 3 _ Sensor
NU-8631 Water Jacket Dual Wave IR Water Pan, Convection
(160 L) (0.5 - 21%)
13
Incubator Options
[C]
[A]
[B]
14
Options and Accessories
Stainless Steel Shelves Copper Shelves Copper Water Pan Automatic Tank Switch
Single Stage CO2 Regulator Two Stage CO2 Regulator Two Stage N2 Regulator Tubing Kit
Platform with Castors / CO2 Analyzer Fyrite Kit (Dry) Surge Suppressor
Leg Levelers Moisture Proof Duplex Outlet
can be used inside the growth - or -
chamber to power equipment O2 Analyzer Fyrite Kit
such as a shaker or roller. (Dry) 0-20%
15
Direct Heat model NU-5700
Model NU-5700 shown featuring add on accessory Platform with Castors / Leg Levelers
Size: 18” x 18 ¾” (457 x 476 mm) Supplied: 4 Shelves Max. Capacity: 16 Shelves Max. Weight Capacity: 25 lbs. (9 kg) per Shelf / 125 lbs. (23 kg) per Incubator
Dual Temperature Sensor Probes Guide Brackets) 20 PSIG (1.4 BAR) Input CO2 Control Logic:
Automatic CO2 Tank Switch Pressures Maximum. Two-Stage Fixed Algorithm / Manual
Infrared (IR) CO2 Sensor Environmental Adaptable.
(External) Gas Regulators Required.
Dual Sterilization Cycles Default Set Point: 5%
(NU-5710, 5720, 5731, 5741) Left Hinged Door Swing Temperature Control System
Sectioned Inner Door (4 Sections) CO2 Range: 0.1 to 20%.
Humidity Control System Temperature Sensor Type: (0.0 Set Point Idles System)
(NU-5720, 5741) Additional Stainless Steel Precision Integrated Circuit
Shelves with Guide Brackets CO2 Accuracy: ± 0.1%
O2 Control System Default Set Point: 37°C
(NU-5731, 5741) CO2 Analyzer Fyrite Kit CO2 Recovery: Up to 5%
Chamber Temperature Range: -0.50% / +0.20% in
Four (4) Stainless Steel Shelves (Dry) 0-20%
5°C to 55°C (5°C Above 5 Minutes Average.
Eight (8) Stainless Steel Replacement Fluid for Ambient to 30°C Max. Ambient)
CO2 Analyzer CO2 Display Resolution: 0.1%
Shelf Guides Chamber Temperature
Four (4) Wall Brackets Surge Protector Uniformity: ± 0.3°C @ 37°C RH (NU-5720 / 5741)
Right Hinged Door Swing CO2 Regulator (2 Stage)
Temperature Accuracy: ± 0.1°C Default Set-Point: 90%
Remote Alarm N2 Regulator (2 Stage) Temperature Recovery:
RH Range: Ambient to 90%
Output Contacts Platform with Castors 0.12°C/Minute Average RH Accuracy: +5% / -3%
4 to 20 mA Analog Output Temperature Display Resolution:
RH Recovery: 90% + 5% 25 min.
Electrical Requirements
RS-485 Communication 0.1°C
Startup Power: 475 watts Water Tank Capacity: 3 Liters
Minimum Qualifications for
USB Port
Running Power: 250 watts Sterilization:
CO2 Sample Port 145 DEG Cycle 135°C @ 2 hr O2 (NU-5731 / 5741)
Decon Cycle: 750 watts
Adjustable Leg Levelers 95 DEG Cycle 85°C @ 9 hr
Heat Rejected: 14 BTU / min. Zirconia Ceramic Sensor
Access Port and Plug with Door and Perimeter: Default Set-Point: 21%
Breather Holes Proportional base duty cycle
based on Temperature set point O2 Range: 0.5 to 21%
One (1) Water Pan
and -20 to +20% manually O2 Accuracy: ± 0.25%
One (1) Electrical Cord adjustable to adapt to ambient
O2 Recovery: 5% ± 2% / 15 min.
conditions.
16
Specifications
Model NU-5800 shown featuring add on accessory Platform with Castors / Leg Levelers
Size: 19 ¾” x 18 ¾” (502 x 476 mm) Supplied: 4 Shelves Max. Capacity: 20 Shelves Max. Weight Capacity: 25 lbs. (9 kg) per Shelf / 125 lbs (23 kg) per Incubator
17
Water Jacket model NU-8600
Model NU-8600 shown featuring add on accessory Platform with Castors / Leg Levelers
Size: 18” x 18 ¾” (457 x 476 mm) Supplied: 4 Shelves Max. Capacity: 16 Shelves Max. Weight Capacity: 25 lbs. (9 kg) per Shelf / 125 lbs. (23 kg) per Incubator
Standard Features Optional Features Temperature Control System C02 Control Systems
NuTouch Electronic Control Copper Surface (Interior Temperature Sensor Type: CO2 Sensor Type:
System Chamber) Precision Integrated Circuit Infrared Single Source
100% Stainless Steel Coved Copper Surface (Shelving and Default Set Point: 37°C Dual Wave Length
Interior Chamber Guide Brackets)
Chamber Temperature Range: CO2 Control Logic:
Dual Temperature Sensor Automatic CO2 Tank Switch 5°C to 55°C (5°C Above Fixed Algorithm / Manual
Probes (External) Ambient to 30°C Max. Ambient) Environmental Adaptable.
Infrared (IR) CO2 Sensor Left Hinged Door Swing Chamber Temperature Default Set Point: 5%
O2 Control System Sectioned Inner Door (4 Sections) Uniformity: ± 0.2°C @ 37°C CO2 Range: 0.1 to 20%.
(NU-8631)
Temperature Accuracy: ± 0.1°C (0.0 Set Point Idles System)
Additional Stainless Steel
Four (4) Stainless Steel Shelves Shelves with Guide Brackets Temperature Recovery: CO2 Accuracy: ± 0.1%
Eight (8) Stainless Steel CO2 Analyzer Fyrite Kit 0.12°C/Minute Average
Shelf Guides (Dry) 0-20% Temperature Display Resolution: CO2 Recovery: Up to 5%
0.1°C -0.50% / +0.20% in
Four (4) Wall Brackets Replacement Fluid for
CO2 Analyzer Door and Perimeter: 5 Minutes Average.
Right Hinged Door Swing
Proportional base duty cycle CO2 Display Resolution: 0.1%
Remote Alarm Surge Protector
based on Temperature set
Output Contacts CO2 Regulator (2 Stage) point and -20 to +20% manually O2 (NU-8631)
4 to 20 mA Analog Output N2 Regulator (2 Stage)s adjustable to adapt to ambient Zirconia Ceramic Sensor
conditions.
RS-485 Communication Platform with Castors Default Set-Point: 21%
USB Port O2 Range: 0.5 to 21%
Electrical Requirements
CO2 Sample Port O2 Accuracy: ± 0.25%
Startup Power: 475 watts
Adjustable Leg Levelers
O2 Recovery: 5% ± 2% / 15 min.
Running Power: 250 watts
Access Port and Plug with
Heat Rejected: 14 BTU / min.
Breather Holes
One (1) Water Pan Utility Connections
One (1) Electrical Cord
Gas Connections: 0.25 in.
(6.3 mm) Tubing Connections
Gas Input Pressure: 20 PSIG
(1.4 BAR) Input Pressures
Maximum. Two-Stage Gas
Regulators Required.
18
Laboratory Equipment
NuAire offers a variety of Laboratory Equipment to meet the needs of the research, vivarium, pharmacy, or environmental
laboratory and more. Join the NuAire family and complete your laboratory with complementary NuAire Quality products.
Mini-Centrifuges
Ultralow Freezers Laminar Airflow Workstations Compounding Isolators
Find amazing prices on NuAire Laboratory Equipment with contracts, group purchasing organizations, and more.
CONTRACTED SUPPLIER OF
19
Your Local NuAire Partner
SHARE A PICTURE AND TAG YOUR NUAIRE CO2 INCUBATOR USING #MYNUAIRE