An accessory port is standard on all models The inner glass door features a cam action The gasket flange on the inner door faces
providing power to accessories such as bottle door handle to create a tight seal against the towards the laboratory environment keeping
rollers and flask shakers. gasket eliminating potential leaks saving gas unwanted growth isolated from the growth
and lowering operating costs. chamber. The gasket may be removed and
2 autoclaved separately if so desired.
Microbiological CO2 Incubators

CO2 Incubators

About NuAire. For more than 45 years, NuAire has been committed to bringing you the highest-quality, most dependable
laboratory products on the market. We are universally recognized as one of the world’s leading providers of reliable equipment
for the most demanding environments, including Biological Safety Cabinets, CO2 Incubators,Laminar Air Flow workstations,
Ultra Low Temperature Freezers, Centrifuges,Animal Transfer Stations, Pharmacy Compounding Isolators, Polypropylene Fume
Hoods, Polypropylene Casework, and a variety of complementary products and systems. You can depend on our products to
feature brilliant but practical design, and we pay keen attention to every step of the production process, from fabrication to
assembly to thorough testing. As a NuAire customer, you can also rely on us for outstanding value and dependable service -
the cornerstones of our reputation as the leading provider of laboratory products internationally.

In-VitroCell ES (Energy Saver) CO2 Incubators are designed to provide a reliable controlled in-vitro environment for
optimum tissue cell culture growth as well as the storage and preservation of gametes and animal tissue cell cultures intended
for research at or near body temperature. In-VitroCell CO2 Incubators provides accurate and precise control of humidity,
temperature, CO2, and sterility.

NU-5700 NU-5800 NU-8600


Direct Heat CO 2 Incubator Direct Heat CO 2 Incubator Water Jacketed CO 2 Incubator
5.65 Ft3 (160 Liter) 7 ft3 (200 Liter) 5.65 Ft3 (160 Liter)

3
4
NuTouch

NuTouch Electronic Control System

The NuTouch Electronic Control System (ECS) is a color 127 x 178 mm (5 x 7-inch) touchscreen designed for
high user adoption. Designed after smart-phone technology, NuTouch creates a unique product experience
providing an easy method to control, monitor, and notify. Help screens offer a step-by-step guide to assist in
procedures such as running a sterilization cycle. User activated help pop-up descriptions are available if an
item or icon is unclear. For example, pressing the text “CO2” on the main screen provides the description “This
control setting specifies the measured current value of Carbon Dioxide (CO2) inside the Incubator Chamber.“

Feature Highlights: Sample NuTouch Control Screens:


• Available in English, Spanish, German & French
• Customizable service reminders
• Alarm notifications
• Visual history performance
• On-screen help
• Password protection
• USB Port - Easily download historical data and
update software
• Power Recovery Mode - Assists with the
CO2 History provides a 7-day report of CO2 Temperature History provides a 7-day report of
dissipation of condensation in the event of a power performance as it relates to system set point. temperature performance as it relates to system set point.

outrage
• Temperature Recovery Mode - Activated in the
event of continuous chamber temperature loss,
increased power is routed to heaters until chamber
temperature returns to normal

System Settings menu allows access to CO2 Service Settings allows service personnel to calibrate
incubator information such as performance, system parameters and diagnose service difficulties.
service, system information, and more.

5
Rounded interior corners in the growth chamber
promote more thorough cleaning by eliminating
tight crevasses found in 90-degree corners.

6
Constant Contamination Control

Contamination-Free Design

Construction
The growth chamber is constructed of 16 gauge, type 304L polished stainless steel using a crevice-free design.
The growth chamber walls are completely smooth with rounded corners which allow more complete contact
between the chamber surface and cleaning solutions than a typical 90-degree corner. Shelving, supports and
guide rails are easily removable and can be autoclaved or left in the chamber during a sterilization cycle.

Dual Sterilization Cycles


In-VitroCell Direct Heat CO2 Incubators offer a 145°C high-temperature dry
cycle, and a 95°C high-temperature humidified cycle to eradicate potential
contamination left over in the chamber from user interaction. Each cycle can be 95 °C 145 °C
run as an overnight procedure as part of a regular cleaning plan, perfect when
HUMIDIFIED DRY
DECONTAMINATION DECONTAMINATION
switching cell lines. The NuTouch ECS provides step by step directions how to
initiate the sterilization process. Interior components such as shelving can remain
in the chamber during the sterilization process.
Featured on Sterilization Cycle models only.

7
Closed Loop HEPA Filtration

[E]

Keep Contamination Out


In-VitroCell CO2 incubators are designed with characteristics
similar to an ISO Class 5 Clean Room. The growth
chamber maintains a slightly positive pressure relative to
the surrounding lab, preventing entry of contaminants. + Positive +
Recirculated chamber air and supply gas pass through
99.99% HEPA filters, and the air change rate is once every Direction
20 to 30 minutes to minimize cell desiccation. A sensor bay of Filtered
Outlet Flow
continually samples the chamber environment and makes [D]
adjustments when needed.

[A] [B] [C]

HEPA Filtered Air Chamber Sampled Air

Airflow pattern within the incubator, and sensor bay continuously sampling the growth environment.
[A] HEPA Filter [B] Air Pump [C] Sensor Bay [D] Water Pan [E] Air Inlet Tube

The Closed Loop HEPA filtration system includes filters outside the growth chamber, convenient to service
or replace, with minimal change to the growth environment.

8
Optional Surfaces

Copper Surfaces

Copper Option
Add copper surfaces to the incubator growth chamber and
shelving to reduce bacteria and minimize potential incubator
contamination.

Shelves and water pans fabricated from copper are available as options.

Reduce the risk of contamination with the option of


a growth chamber fabricated from copper

9
Temperature Uniformity and Recovery

Because your samples matter, In-VitroCell CO2 Incubators from NuAire offer the fastest recovery
times in the industry.

Temperature Uniformity and Recovery


The Direct heating elements or the water jacket are wrapped in R5 insulation which surrounds the growth chamber. Dual
temperature sensor probes relay information back to the NuTouch Electronic Control System and make adjustments as needed.

SET POINT
NU-5810 Temperature Recovery After 30 Sec. Door Opening
37.2
37.1
37.0 0.12 °C
36.9 PER MINUTE
Temperature, C°

36.8 (Average)
Open Return to 37° C
36.7
36.6
Closed
Set Point 15 Min. TEMPERATURE
36.5 After Door Closed
36.4
36.3
36.2
36.1
36.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Time, Minutes

Temp. Chamber Temperature Uniformity (Direct Heat): ± 0.3°C @ 37°C Temperature Accuracy: ± 0.1% Temperature Recovery: 0.12°C/Min. Ave.
Chamber Temperature Uniformity (Water Jacketed): ± 0.2°C @ 37°C Temperature Accuracy: ± 0.1% Temperature Recovery: 0.12°C/Min. Ave.

10
Temperature and CO2 Control

CO2 Sensitivity and Accuracy

Sensitivity and Accuracy of Gas Control


A microprocessor-based, non-dispersive, single source dual wave infrared (IR) sensor controls CO2 levels within the chamber.
The wavelengths used are absorbed by only CO2 making the measurement insensitive to other components such as water
vapor. Advanced design provides a very stable output minimizing drift and requiring less frequent calibration.

NU-5800 Series C02 30s Door Opening Recovery SET POINT


6.0
5.5 UP TO
5.0 5%
4.5 +0.2% / -0.5%
4.0 IN 5 MINUTES
3.5 CO2 Percentage (Average)
Door is
3.0
Closed Meets Recovery Recovered 5.3 Minutes CO2
2.5 Specification After Door Opening
2.0
1.5
1.0
0.5 Door Open Recovery Delay Ends
0.0
0.0 0.3 0.7 1.0 1.3 1.7 2.0 2.3 2.7 3.0 3.3 3.7 4.0 4.3 4.7 5.0 5.3 5.7 6.0 6.3 6.7 7.0
Time, Minutes

CO2 Range: 0.1 to 20% Accuracy: ± 0.1% Recovery: Up to 5% -0.50% / +0.20% in 5 Minutes Average

11
O2 and Relative Humidity Control

Oxygen Control - Hypoxic Studies


SET POINT
For more sensitive cells lines prone to stress and DNA damage, 21 % + 0.25 %
CO2 Incubator models featuring Oxygen control utilize an O2
sensor to monitor oxygen in the growth chamber. Nitrogen SET POINT SET POINT 5%
+ 2.0 %
(N2) gas is injected to suppress oxygen to set point. An 15 MINUTES
extensive O2 range applies to various research applications 0.5 % - 0.25 % (On Average)

including the brain, eyes, liver, heart, kidneys, and more. O2 RANGE O2 ACCURACY O2 RECOVERY
Featured on O2 Control models only.

O2 Range: 0.5 to 21% Accuracy: ± 0.25% Recovery: 5% ± 2.0% within 15 Minutes

Humidity Control
Relative humidity levels up to 90% are achieved in the growth SET POINT
chamber through the use of a 3-liter reservoir external to the 90 % +5 %
chamber. The chamber air is routed through the water vapor
SET POINT SET POINT 90 %
saturated the air in an evaporate box to add humidity when ± 5%
the RH sensor indicates more humidity is needed to meet 25 MINUTES
set point.
AMBIENT -3 % (On Average)

Featured on RH models only.


RH RANGE RH ACCURACY RH RECOVERY

RH Range: Ambient to 90% Accuracy: + 5% / - 3% Recovery: 5% within 25 Minutes

12
CO2 Incubator Selection

Selection Guide

NU-5700 NU-5800 NU-8600

Chamber Temperature
Model CO2 Sensor Sterilization Cycles RH (Humidity) Control O2 Control
Volume Control
5.65 ft 3 _ _
NU-5700 Direct Heat Dual Wave IR Water Pan, Convection
(160 L)
5.65 ft 3 _
NU-5710 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified Water Pan, Convection
(160 L)
5.65 ft 3 Reservoir, _
NU-5720 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified
(160 L) Sensor Controlled
5.65 ft 3 Sensor
NU-5731 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified Water Pan, Convection
(160 L) (0.5 - 21%)
5.65 ft 3 Reservoir, Sensor
NU-5741 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified
(160 L) Sensor Controlled (0.5 - 21%)
7.06 ft 3 _ _
NU-5800 Direct Heat Dual Wave IR Water Pan, Convection
(200 L)
7.06 ft 3 _
NU-5810 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified Water Pan, Convection
(200 L)
7.06 ft 3 Reservoir, _
NU-5820 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified
(200 L) Sensor Controlled
7.06 ft 3 Sensor
NU-5831 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified Water Pan, Convection
(200 L) (0.5 - 21%)
7.06 ft 3 Reservoir, Sensor
NU-5841 Direct Heat Dual Wave IR 145°C Dry / 95°C Humidified
(200 L) Sensor Controlled (0.5 - 21%)
5.65 ft 3 _ _
NU-8600 Water Jacket Dual Wave IR Water Pan, Convection
(160 L)
5.65 ft 3 _ Sensor
NU-8631 Water Jacket Dual Wave IR Water Pan, Convection
(160 L) (0.5 - 21%)

13
Incubator Options

[C]
[A]
[B]

Gas Tight Sectioned Inner Doors


Sectioned inner doors allow access to separate area of
the growth chamber. A latch centered between each set of
doors allows access to either with a turn of 90 degrees. [A]
Each door is sealed with a gasket [B], and secured with NU-5700/5800 Series

a stainless steel hinge [C]. This option improves recovery


times by limiting thermal loss and the amount of chamber
atmosphere escaping when the
main door is opened.
NU-8600 Series

Brackets. Safely stack In-VitroCell Left Hinge Door Swing


Model Inner Door Sections
Direct Heat and Water Jacketed
CO2 Incubators.
NU-58XX 6 Sections
NU-57XX 4 Sections
NU-86XX

14
Options and Accessories

Stainless Steel Shelves Copper Shelves Copper Water Pan Automatic Tank Switch

Single Stage CO2 Regulator Two Stage CO2 Regulator Two Stage N2 Regulator Tubing Kit

Platform with Castors / CO2 Analyzer Fyrite Kit (Dry) Surge Suppressor
Leg Levelers Moisture Proof Duplex Outlet
can be used inside the growth - or -
chamber to power equipment O2 Analyzer Fyrite Kit
such as a shaker or roller. (Dry) 0-20%

15
Direct Heat model NU-5700

Model NU-5700 shown featuring add on accessory Platform with Castors / Leg Levelers

Chamber Electrical Exterior Dimensions Chamber Dimensions


Model Net Weight
Volume Configuration (W x D x H) (W x D x H)
5.65 ft 3 115V, 50/60Hz 25 1/2 x 27 1/2 x 36 1/8 in 20 1/4 x 20 1/2 x 24 in
NU-57XX (160 L) E: 230V, 50/60Hz (648 x 699 x 894 mm) (514 x 525 x 610 mm)
220 lbs. (100 kg.)
* Specify models with appropriate letter suffix for electrical specifications. “NU-5700E” for 230 VAC 50/60 Hz

Size: 18” x 18 ¾” (457 x 476 mm) Supplied: 4 Shelves Max. Capacity: 16 Shelves Max. Weight Capacity: 25 lbs. (9 kg) per Shelf / 125 lbs. (23 kg) per Incubator

Standard Features Optional Features Utility Connections C02 Control Systems


NuTouch Electronic Control System Copper Surface (Interior 
Gas Connections: 0.25 in. CO2 Sensor Type:
100% Stainless Steel Coved Chamber) (6.3 mm) Tubing Connections Infrared Single Source
Interior Chamber Copper Surface (Shelving and Gas Input Pressure: Dual Wave Length

Dual Temperature Sensor Probes Guide Brackets) 20 PSIG (1.4 BAR) Input CO2 Control Logic:
Automatic CO2 Tank Switch Pressures Maximum. Two-Stage Fixed Algorithm / Manual
Infrared (IR) CO2 Sensor Environmental Adaptable.
(External) Gas Regulators Required.
Dual Sterilization Cycles Default Set Point: 5%
(NU-5710, 5720, 5731, 5741) Left Hinged Door Swing Temperature Control System
Sectioned Inner Door (4 Sections) CO2 Range: 0.1 to 20%.
Humidity Control System Temperature Sensor Type: (0.0 Set Point Idles System)
(NU-5720, 5741) Additional Stainless Steel Precision Integrated Circuit
Shelves with Guide Brackets CO2 Accuracy: ± 0.1%
O2 Control System Default Set Point: 37°C
(NU-5731, 5741) CO2 Analyzer Fyrite Kit CO2 Recovery: Up to 5%
Chamber Temperature Range: -0.50% / +0.20% in
Four (4) Stainless Steel Shelves (Dry) 0-20%
5°C to 55°C (5°C Above 5 Minutes Average.
Eight (8) Stainless Steel Replacement Fluid for Ambient to 30°C Max. Ambient)
CO2 Analyzer CO2 Display Resolution: 0.1%
Shelf Guides Chamber Temperature
Four (4) Wall Brackets Surge Protector Uniformity: ± 0.3°C @ 37°C RH (NU-5720 / 5741)
Right Hinged Door Swing CO2 Regulator (2 Stage) 
Temperature Accuracy: ± 0.1°C Default Set-Point: 90%
Remote Alarm N2 Regulator (2 Stage) Temperature Recovery: 
RH Range: Ambient to 90%
Output Contacts Platform with Castors 0.12°C/Minute Average RH Accuracy: +5% / -3%
4 to 20 mA Analog Output Temperature Display Resolution: 
RH Recovery: 90% + 5% 25 min.
Electrical Requirements
RS-485 Communication 0.1°C
Startup Power: 475 watts Water Tank Capacity: 3 Liters
Minimum Qualifications for
USB Port
Running Power: 250 watts Sterilization:
CO2 Sample Port 145 DEG Cycle 135°C @ 2 hr O2 (NU-5731 / 5741)
Decon Cycle: 750 watts
Adjustable Leg Levelers 95 DEG Cycle 85°C @ 9 hr
Heat Rejected: 14 BTU / min. Zirconia Ceramic Sensor
Access Port and Plug with Door and Perimeter: Default Set-Point: 21%
Breather Holes Proportional base duty cycle
based on Temperature set point O2 Range: 0.5 to 21%
One (1) Water Pan
and -20 to +20% manually O2 Accuracy: ± 0.25%
One (1) Electrical Cord adjustable to adapt to ambient 
O2 Recovery: 5% ± 2% / 15 min.
conditions.

16
Specifications

Direct Heat model NU-5800

Model NU-5800 shown featuring add on accessory Platform with Castors / Leg Levelers

Chamber Electrical Exterior Dimensions Chamber Dimensions


Model Net Weight
Volume Configuration (W x D x H) (W x D x H)
7.06 ft 3 115V, 50/60Hz 26 3/4 x 27 x 39 1/2 in 21 1/4 x 20 x 28.5 in
NU-58xx (200 L) E: 230V, 50/60Hz (680 x 691 x 1008 mm) (540 x 510 x 724 mm)
235 lbs. (106 kg.)
* Specify models with appropriate letter suffix for electrical specifications. “NU-5700E” for 230 VAC 50/60 Hz

Size: 19 ¾” x 18 ¾” (502 x 476 mm) Supplied: 4 Shelves Max. Capacity: 20 Shelves Max. Weight Capacity: 25 lbs. (9 kg) per Shelf / 125 lbs (23 kg) per Incubator

Standard Features Optional Features Utility Connections C02 Control Systems


NuTouch Electronic Control System Copper Surface (Interior 
Gas Connections: 0.25 in. CO2 Sensor Type:
100% Stainless Steel Coved Chamber) (6.3 mm) Tubing Connections Infrared Single Source
Interior Chamber Copper Surface (Shelving and 
Gas Input Pressure: 20 PSIG Dual Wave Length
Dual Temperature Sensor Guide Brackets) (1.4 BAR) Input Pressures CO2 Control Logic:
Probes Automatic CO2 Tank Switch Maximum. Two-Stage Gas Fixed Algorithm / Manual
(External) Regulators Required. Environmental Adaptable.
Infrared (IR) CO2 Sensor
Left Hinged Door Swing Default Set Point: 5%
Dual Sterilization Cycles Temperature Control System
(NU-5810, 5820, 5831, 5841) Sectioned Inner Door (6 Sections) CO2 Range: 0.1 to 20%.
Temperature Sensor Type:
(0.0 Set Point Idles System)
Humidity Control System Additional Stainless Steel Precision Integrated Circuit
(NU-5820, 5841) Shelves with Guide Brackets CO2 Accuracy: ± 0.1%
Default Set Point: 37°C
O2 Control System CO2 Analyzer Fyrite Kit CO2 Recovery: Up to 5%
Chamber Temperature Range:
(NU-5831, 5841) (Dry) 0-20% -0.50% / +0.20% in
5°C to 55°C (5°C Above 5 Minutes Average.
Four (4) Stainless Steel Shelves Replacement Fluid for Ambient to 30°C Max. Ambient)
Eight (8) Stainless Steel CO2 Analyzer CO2 Display Resolution: 0.1%
Chamber Temperature
Shelf Guides Surge Protector Uniformity: ± 0.3°C @ 37°C RH (NU-5820 / 5841)
Four (4) Wall Brackets CO2 Regulator (2 Stage) 
Temperature Accuracy: ± 0.1°C Default Set-Point: 90%
Right Hinged Door Swing N2 Regulator (2 Stage) Temperature Recovery: 
RH Range: Ambient to 90%
Remote Alarm Platform with Castors 0.12°C/Minute Average
Output Contacts RH Accuracy: +5% / -3%
Temperature Display Resolution:
Electrical Requirements 
RH Recovery: 90% + 5% 25 min.
4 to 20 mA Analog Output 0.1°C
Startup Power: 625 watts Water Tank Capacity: 3 Liters
RS-485 Communication Minimum Qualifications for
Running Power: 250 watts Sterilization:
USB Port O2 (NU-5831 / 5841)
Decon Cycle: 995 watts 145 DEG Cycle 135°C @ 2 hr
CO2 Sample Port Zirconia Ceramic Sensor
Heat Rejected: 14 BTU / min. 95 DEG Cycle 85°C @ 9 hr
Adjustable Leg Levelers Default Set-Point: 21%
Door and Perimeter:
Access Port and Plug with Proportional base duty cycle O2 Range: 0.5 to 21%
Breather Holes based on Temperature set point O2 Accuracy: ± 0.25%
One (1) Water Pan and -20 to +20% manually
adjustable to adapt to ambient 
O2 Recovery: 5% ± 2% / 15 min.
One (1) Electrical Cord
conditions.

17
Water Jacket model NU-8600

Model NU-8600 shown featuring add on accessory Platform with Castors / Leg Levelers

Chamber Electrical Exterior Dimensions Chamber Dimensions Net Weight


Model
Volume Configuration (W x D x H) (W x D x H) (with water and shelving)

5.65 ft 3 115V, 50/60Hz 25 5/8 x 27 x 37 3/4 in 20 3/8 x 20 5/8 x 24 in


NU-86XX (160 L) E: 230V, 50/60Hz (650 x 685 x 958 mm) (518 x 524 x 611 mm)
403 lbs. (183 kg.)
* Specify models with appropriate letter suffix for electrical specifications. “NU-5700E” for 230 VAC 50/60 Hz

Size: 18” x 18 ¾” (457 x 476 mm) Supplied: 4 Shelves Max. Capacity: 16 Shelves Max. Weight Capacity: 25 lbs. (9 kg) per Shelf / 125 lbs. (23 kg) per Incubator

Standard Features Optional Features Temperature Control System C02 Control Systems
NuTouch Electronic Control Copper Surface (Interior Temperature Sensor Type: CO2 Sensor Type:
System Chamber) Precision Integrated Circuit Infrared Single Source
100% Stainless Steel Coved Copper Surface (Shelving and Default Set Point: 37°C Dual Wave Length
Interior Chamber Guide Brackets) 
Chamber Temperature Range: CO2 Control Logic:
Dual Temperature Sensor Automatic CO2 Tank Switch 5°C to 55°C (5°C Above Fixed Algorithm / Manual
Probes (External) Ambient to 30°C Max. Ambient) Environmental Adaptable.

Infrared (IR) CO2 Sensor Left Hinged Door Swing Chamber Temperature Default Set Point: 5%

O2 Control System Sectioned Inner Door (4 Sections) Uniformity: ± 0.2°C @ 37°C CO2 Range: 0.1 to 20%.
(NU-8631) 
Temperature Accuracy: ± 0.1°C (0.0 Set Point Idles System)
Additional Stainless Steel
Four (4) Stainless Steel Shelves Shelves with Guide Brackets Temperature Recovery: CO2 Accuracy: ± 0.1%

Eight (8) Stainless Steel CO2 Analyzer Fyrite Kit 0.12°C/Minute Average
Shelf Guides (Dry) 0-20% Temperature Display Resolution: CO2 Recovery: Up to 5%
0.1°C -0.50% / +0.20% in
Four (4) Wall Brackets Replacement Fluid for
CO2 Analyzer Door and Perimeter: 5 Minutes Average.
Right Hinged Door Swing
Proportional base duty cycle CO2 Display Resolution: 0.1%
Remote Alarm Surge Protector
based on Temperature set
Output Contacts CO2 Regulator (2 Stage) point and -20 to +20% manually O2 (NU-8631)
4 to 20 mA Analog Output N2 Regulator (2 Stage)s adjustable to adapt to ambient Zirconia Ceramic Sensor
conditions.
RS-485 Communication Platform with Castors Default Set-Point: 21%
USB Port O2 Range: 0.5 to 21%
Electrical Requirements
CO2 Sample Port O2 Accuracy: ± 0.25%
Startup Power: 475 watts
Adjustable Leg Levelers 
O2 Recovery: 5% ± 2% / 15 min.
Running Power: 250 watts
Access Port and Plug with
Heat Rejected: 14 BTU / min.
Breather Holes
One (1) Water Pan Utility Connections
One (1) Electrical Cord 
Gas Connections: 0.25 in.
(6.3 mm) Tubing Connections

Gas Input Pressure: 20 PSIG
(1.4 BAR) Input Pressures
Maximum. Two-Stage Gas
Regulators Required.

18
Laboratory Equipment

Complete Your Laboratory

NuAire offers a variety of Laboratory Equipment to meet the needs of the research, vivarium, pharmacy, or environmental
laboratory and more. Join the NuAire family and complete your laboratory with complementary NuAire Quality products.

Biological Safety Cabinets CO2 Incubators Centrifuges CENTRIFUGES

Mini-Centrifuges
Ultralow Freezers Laminar Airflow Workstations Compounding Isolators

Polypropylene Fume Hoods Custom Solutions


Animal Laboratory Products and Casework

Find amazing prices on NuAire Laboratory Equipment with contracts, group purchasing organizations, and more.

CONTRACTED SUPPLIER OF

19
Your Local NuAire Partner

For more information please visit


www.nuaire.com or call 1.763.553.1270

SHARE A PICTURE AND TAG YOUR NUAIRE CO2 INCUBATOR USING #MYNUAIRE

© Copyright 2019. NuAire, Inc. All Rights Reserved.


20-1237-B-D-EN-8-0419 Request a quote online

You might also like