Calcul Coalescer L-L

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 4

SOT6 Ø2200

DATE INTRARE calculations


U.M. input data
Vc [ft3] 67.46 Coalescer volume
C1 - 164 for Plate -Pack w/horizontal sheets
Q [US GPM] 25.18 Liquid/Liquid emulsion flow
h [inch] 0.5 Corrugated plate spacing or structured packing crimp height
d [micrones] 40 Minimum droplet diameter,
μ [cP] 6.9 Continuos phase viscozity
ΔS.G. kgf/m3 0.13 Specific gravity diference between the continuos and dispersed phase
γoil kgf/m 3
0.87 Specific gravity for oil
γwater kgf/m3 1.006 Specific gravity for water
ID [mm] 2176 Internal vesssel diameter
hd [mm] 1760 oil overflow height
hmin [mm] 310 Minimum avaialable height from bottom of vessel
Ad ft2
30.19 Available area for coalescer
Wd ft 2.23
Consideratii:
Scop: separare titei emulsionat din apa
Faza dispersata este considerata a fi 50% din faza continua
Total debit: 5.72 m3/h 25.18 GPM
Faza continua: titei 2.86 m /h
3
12.59 GPM
Faza dispersata : apa 2.86 m /h
3
12.59 GPM

W= 2.23 ft se alege latimea coalescerului 0.8 m


0.68 m

Actual coalescer volume: 2.24 m3


sau 79.24 ft3
Min drop size @ Actual thickness 36.9 μm
SOT6 Ø2200
DATE INTRARE
U.M.
Vc [ft3] 17.38 Coalescer volume
C1 - 164 for Plate -Pack w/horizontal sheets
Q [US GPM] 12.59 Liquid/Liquid emulsion flow
h [inch] 0.5 Corrugated plate spacing or structured packing crimp height
d [micrones] 15 Minimum droplet diameter,
μ [cP] 0.5 Continuos phase viscozity
ΔS.G. kgf/m3 0.13 Specific gravity diference between the continuos and dispersed p
γoil kgf/m 3
0.87 Specific gravity for oil
γwater kgf/m3 1.006 Specific gravity for water
ID [mm] 2176 Internal vesssel diameter
hd [mm] 1760 oil overflow height
hmin [mm] 310 Minimum avaialable height from bottom of vessel

Consideratii:
Scop: separare apa emulsionata din titei
Faza dispersata este considerata a fi 1% din faza continua
Total debit: 2.86 m3/h 12.5922 GPM
Faza continua: apa 2.83 m /h
3
12.46628 GPM
Faza dispersata : titei 0.03 m3/h 0.125922 GPM

W= se alege latimea coalescerului 2 ft


Suprafata necesara: 8.690 ft2 0.807334 m2 rezulta inaltimea:
Actual coalescer volume: 0.521 m3
sau 18.406 ft3
Min drop size @ Actual thickness 14.6 μm
calculations
input data

d packing crimp height

e continuos and dispersed phase

om of vessel

rezulta inaltimea: 0.5 m (suprafata efect.)= 0.855 m2