1) The document contains lighting design plans for a service road and flyover near TCS 01. 2) For the service road, 249W LED luminaires arranged in a double row configuration with 34m pole spacing are proposed. Illuminance levels between 40-82 lux are calculated. 3) For the flyover, the same 249W LED luminaires with 34m pole spacing are proposed. Illuminance levels between 40-75 lux are calculated for the two roadways.

Uploaded by

Vishnu Prajapati
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
76 views6 pages

TCS 01

1) The document contains lighting design plans for a service road and flyover near TCS 01. 2) For the service road, 249W LED luminaires arranged in a double row configuration with 34m pole spacing are proposed. Illuminance levels between 40-82 lux are calculated. 3) For the flyover, the same 249W LED luminaires with 34m pole spacing are proposed. Illuminance levels between 40-75 lux are calculated for the two roadways.

Uploaded by

Vishnu Prajapati
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Project 1

16.12.2018

Bajaj Electricals ltd Operator Rohit Sharma


Telephone 9716940017
DLF Moti nagar Fax
e-Mail [email protected]

TCS 01 SERVICE ROAD / Planning data

Street Profile

Service Road (Width: 7.500 m)


Seprator (Width: 1.000 m)
Flyover (Width: 23.500 m)
Seprator (Width: 1.000 m)
Service Road (Width: 7.500 m)

Light loss factor: 0.85

Luminaire Arrangements

Luminaire: BRTFG 250W LED I


Luminous flux (Luminaire): 33110 lm Maximum luminous intensities
Luminous flux (Lamps): 33110 lm at 70°: 237 cd/klm
Luminaire Wattage: 249.0 W at 80°: 19 cd/klm
Arrangement: Double row, opposing at 90°: 1.02 cd/klm
Pole Distance: 34.000 m Any direction forming the specified angle from the downward vertical, with
Mounting Height (1): 10.200 m the luminaire installed for use.
Height: 10.100 m Arrangement complies with luminous intensity class
Overhang (2): 6.700 m G3.
Boom Angle (3): 5.0 ° Arrangement complies with glare index class D.5.
Boom Length (4): 1.500 m

Page 1
Project 1
16.12.2018

Bajaj Electricals ltd Operator Rohit Sharma


Telephone 9716940017
DLF Moti nagar Fax
e-Mail [email protected]

TCS 01 SERVICE ROAD / Service Road / Value Chart (E)

Values in Lux, Scale 1 : 317

Grid: 12 x 5 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
57 40 82 0.702 0.488

Page 2
Project 1
16.12.2018

Bajaj Electricals ltd Operator Rohit Sharma


Telephone 9716940017
DLF Moti nagar Fax
e-Mail [email protected]

TCS 01 SERVICE ROAD / Service Road / Value Chart (E)

Values in Lux, Scale 1 : 317

Grid: 12 x 5 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
57 40 82 0.702 0.488

Page 3
Project 1
16.12.2018

Bajaj Electricals ltd Operator Rohit Sharma


Telephone 9716940017
DLF Moti nagar Fax
e-Mail [email protected]

TCS 01 FLYOVER / Planning data

Street Profile

Roadway 2 (Width: 10.500 m, Number of lanes: 3, tarmac: R3, q0: 0.070)


Median 1 (Width: 1.500 m, Height: 0.000 m)
Roadway 1 (Width: 10.500 m, Number of lanes: 3, tarmac: R3, q0: 0.070)

Light loss factor: 0.85

Luminaire Arrangements

Luminaire: BRTFG 250W LED I


Luminous flux (Luminaire): 33110 lm Maximum luminous intensities
Luminous flux (Lamps): 33110 lm at 70°: 210 cd/klm
Luminaire Wattage: 249.0 W at 80°: 18 cd/klm
Arrangement: Double row, opposing at 90°: 2.71 cd/klm
Pole Distance: 34.000 m Any direction forming the specified angle from the downward vertical, with
Mounting Height (1): 10.500 m the luminaire installed for use.
Height: 10.402 m Arrangement complies with luminous intensity class
Overhang (2): 0.509 m G3.
Boom Angle (3): 10.0 ° Arrangement complies with glare index class D.5.
Boom Length (4): 0.500 m

Page 4
Project 1
16.12.2018

Bajaj Electricals ltd Operator Rohit Sharma


Telephone 9716940017
DLF Moti nagar Fax
e-Mail [email protected]

TCS 01 FLYOVER / Valuation Field Roadway 1 / Value Chart (E)

Values in Lux, Scale 1 : 286


Not all calculated values could be displayed.

Grid: 12 x 9 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
54 40 75 0.743 0.533

Page 5
Project 1
16.12.2018

Bajaj Electricals ltd Operator Rohit Sharma


Telephone 9716940017
DLF Moti nagar Fax
e-Mail [email protected]

TCS 01 FLYOVER / Valuation Field Roadway 2 / Value Chart (E)

Values in Lux, Scale 1 : 286


Not all calculated values could be displayed.

Grid: 12 x 9 Points
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
54 40 75 0.743 0.533

Page 6