Compact Fans For AC and DC 2016 01 BEN

Download as pdf or txt
Download as pdf or txt
You are on page 1of 272

Compact fans for AC and DC

version 2016-01
Trendsetter in fan technology

Uncompromising quality made by ebm-papst

Among the best.


Trendsetting with innovative technologies. Listening to customers’ needs.
Developing new ideas to meet requirements and realising them with
pioneering spirit. This philosophy has made ebm-papst the technological
leader in the world of fans.

A brand which has very little real competition because every fan is a
product of decades of application expertise gained from large-volume
production and because we are in a position to produce highly efficient
quality products. Our intelligent solutions for electronics cooling ensure
that you are one step ahead of competitors thanks to innovative, reliable
top-quality technology which is cost-favourable and in line with market
requirements. And if required, tailor-made right down to the last detail. In
other words, if you need fans which do not yet actually exist, contact us.

Insist on ebm-papst.
2016-01

2
Information
Table of contents

DC axial fans
Information – Speed setting 178
– The company 4 – Protected fans, Degree of protection: IP 54 / IP 68 181
– GreenTech: The Green Company 6

DC centrifugal fans
– Expertise and technology 8 ACmaxx / EC fans 183
– Tailor-made 10 – ACmaxx axial fans 188
– Optional special designs 12 – GreenTech EC-compact fans 192
– Types of fans 13 – Energy-saving axial fans 194
– Selecting the correct fan 14 – EC axial fans 196
– Fan installation 15 – ACmaxx in-line duct fan 200
– Service life 17
– Definitions 18 AC axial fans 203

DC fans - specials
– Standard test equipment to test the fan characteristics 19 – Axial fans 206
– Type code 20
AC centrifugal fans 231
DC axial fans 25 – Centrifugal fans 233
– Axial fans 31
Accessories 241
DC centrifugal fans 91 – Guard grilles 242

ACmaxx / EC fans
– Centrifugal fans 96 – Filter guard grilles 250
– Cross-flow blowers 138 – Inlet nozzles 252
– Centrifugal fans and blowers 140 – Connection cables 255
– Handheld programmer 256
DC fans - specials 165 – Accessories 257
– Speed signal 168 – Electrical connections 258
– Alarm signal 172
– Vario-Pro® 177
ebm-papst representatives & subsidiaries 265

AC axial fans
AC centrifugal fans
Accessories
Representatives
2016-01

3
Company profile: ebm-papst

The entire scope of ventilation and drive technology: this is the world of ebm-papst. More than 12.000 people – in Germany and throughout the world –
develop, produce and sell our motors and fans. Our global presence and our unique range of products based on a quality standard that surpasses every
other have made us what we are: world market leader in motors and fans. Expertly knowing what our customers need and incessantly striving to arrive
at the perfect application solution for a wide variety of different industries is what determines our daily work.
Those who know us know the high standards we apply to our work and know our creed: to be as close to our customers as possible and to simply be the
best in terms of innovation and reliability.
2016-01

4
Information
DC axial fans
Our history – Our drive of production and throughout all processes: consulting customers,
Rooted in ebm, PAPST and mvl, the three leading innovators in the development, material selection through to picking certified, choice
development and production of motors and fans, ebm-papst has suppliers and on to the production of parts and final delivery. On top of

DC centrifugal fans
established itself as the world market leader. Now as ever, our legendary this, our products have to pass the most rigorous tests under all realistic
inventive spirit shines through in products that set standards in many operating conditions: continuous stress test, salt spray test, vibration test,
segments of industry worldwide. We are proud to say that despite difficult or precision noise measuring, just to mention a few. And the product gets
competition, our performance has always been exemplary and outstanding clearance for serial production only after all the desired characteristics
– in business, in our personal relationship with our customers, and of have been determined to be just right.
course with respect to technology and engineering. For decades, we have Environmental care is another priority with ebm-papst. This is why we

DC fans - specials
contributed to the world of air technology and drive engineering with small have developed our product line in EC technology, which makes for very
revolutions and large milestones. low power consumption. Due to our manufacturing philosophy, there is
To maintain this advantage in skills and knowledge to get maximum absolute focus on environmental care in production, recycling, waste and
quality and thus the highest degree of customer satisfaction, our wastewater disposal.
employees around the world put their passion and dedication to work
for you. Global Domestic
In order to be specialist for customised solutions throughout the world,

ACmaxx / EC fans
Passionately involved in R&D you need strong partners. Global Domestic – i.e. being present all over the
Our catalogues just list the results of our incessant efforts in R&D: world and being a national company in each individual country – is how
products of highest quality and reliability. After all, it is our passion to we have established ourselves in all important markets on this globe with
constantly try something new and improve what we have. In doing so, our successful subsidiaries. And so you will always find ebm-papst close
we take advantage of the latest development methods and state-of- to home, speaking your language, and knowing the demands of your
the-art technology and invest quite heavily in R&D facilities. Best of all, markets. Besides, our worldwide production alliance serves as a basis
though, we rely on excellently trained and skilled engineers and for competitive pricing. Our global services and logistic outlets, i.e. IT

AC axial fans
technicians to be at your service in R&D and Sales & Distribution. networking, safeguard short reaction times and just-in-time delivery.

Producing and safeguarding high-quality products and services All our efforts are documented in a comprehensive quality management
This is our promise without any compromise. Whether produced in one of system, both for products and services. Being certified as complying with
our six factories in Germany or one of our eleven international production the tough requirements of the international standards DIN EN ISO 9001,
sites, our products always have the same high level of quality. This quality ISO/TS 16949-2 and of standard DIN EN ISO 14001 is just one seal of
control is something you can definitely rely on! And this across all levels approval we have received for our unceasing efforts to provide only the AC centrifugal fans
best quality products and services.
Accessories
Representatives
2016-01

5
Sustainability is at the centre of our
thoughts and actions. Out of conviction!

Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked according to the simple but
strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better than the last one in terms of economy and ecology.”
GreenTech is the ultimate expression of our corporate philosophy.

GreenTech is pro-active development. GreenTech is eco-friendly production.


Even in the design phase, the materials and processes we use are GreenTech also stands for maximum energy efficiency in our production
optimised for the greatest possible eco-friendliness, energy balance and processes. There, the intelligent use of industrial waste heat and
– wherever possible – recyclability. We continually improve the material groundwater cooling, photovoltaics and, of course, our own cooling and
and performance of our products, as well as the flow and noise charac- ventilation technology are of the utmost importance. Our most modern
teristics. At the same time, we significantly reduce energy conumption. plant, for instance, consumes 91% less energy than currently specified
Close co-operation with universities and scientific institutes and the and required. In this way, our products contribute to protecting the
professorship we endow in the area of power engineering and regenerative environment, from their origin to their recyclable packaging.
energies allows us to profit from the latest research finings in these fields –
and at the same time ensure highly qualified young academics.

GreenTech
follows a firm
philosophy.

GreenTech is
pro-active
GreenTech development.
pays off
for our
customers.

GreenTech is
eco-friendly
production.
GreenTech is
acknowledged
and certified.
2016-01

6
Information
DC axial fans
GreenTech is acknowledged and certified. Our customers profit from this every day.
Every step in our chain of production meets the stringent standards of The heart of GreenTech is future-oriented EC technology from
environmental specialists and the public. ebm-papst. The EC technology at the core of our most efficient

DC centrifugal fans
This supports our position as Germany‘s most sustainable company motors and fans allows efficiency of up to 90%, saves energy at
2013, as does the DEKRA Award 2012 we received in the category a very high level, significantly extends service life and makes our
“Umwelt – Herausforderung Energiewende / Environment – Challenge: products maintenance-free. These values pay off not only for the
Transition to more sustainable energy systems”, to name only environment, but every cent also pays off for the user! All ebm-papst
a few of a large number of examples. The environmental advantage products – even those for which GreenTech EC technology does not
gained in the performance of the products developed from our Green- (yet) make sense from an application viewpoint – feature the greatest

DC fans - specials
Tech philosophy can also be measured in the fulfillment of the most possible connection of economy and ecology.
stringent energy and environmental standards. In many instances, our
products are already well below the thresholds energy legislation will
impose a few years from now – several times over.

ACmaxx / EC fans
AC axial fans
AC centrifugal fans
Accessories
Representatives
2016-01

7
Expertise and technology

Drive expertise Long service life


For the past 60 years, all conceivable types and applications of drive The bearing system plays a vital role both in the long life time and
engineering have played an essential role at ebm-papst. A commit- quietness of device fans. The SINTEC compact bearing provides most
ment that is the foundation for the development of optimum drive solu- of the device fans with a proven bearing system. Constant low noise
tions – regardless of the type of fan and its usage. DC fans are during the entire operating time and considerably lower shock sensi-
generally equipped with electronically commutated external rotor mo- tivity are the outstanding features of this bearing technology. In
tors; in order to save as much space as possible, commutation elec- addition, with regard to temperature endurance, Sintec compact
tronic components are integrated in the hub of the fan. Our AC fans are bearings can be used without problems in most applications. Despite
mostly driven by shaded-pole or capacitor motors based on the the slightly higher noise and shock sensitivity of ball bearings, this
external rotor principle. In the 3900 and 9900 range of particularly bearing technology should be given preference for fans exposed to
slim fans, internal rotor motors are used. extreme thermal and adverse application conditions (e.g. extreme
environmental conditions, critical installation position, etc.). The
Low-noise performance service life data provided in this catalogue is based on extensive
Our aerodynamically optimised design and high mechanical precision service life tests and mathematically / scientifically proven service
produces outstanding noise properties in series production. So-called life calculations. Our product descriptions are continuously updated
“soft” commutation electronics of the DC fans ensure an excellent with all relevant data obtained from long-term tests.
noise performance. By avoiding steep switching edges when the indi-
vidual coils are switched, this reduces the structure-borne noise from
the motor. Computer-aided measurements and series of analyses per-
formed in a state-of-the-art sound measuring chamber are conducted
on each fan model from the very beginning.
2016-01

8
Information
DC axial fans
DC centrifugal fans
DC fans - specials
Streamline: Aerodynamics Safety is included
With the aid of state-of-the-art computer programs, we are able to It goes without saying that all ebm-papst fans conform to the approval
optimise the fan impellers and the inner shape of the housing. Air requirements of the VDE (Association of German Electrical Engineers)
output and available motor performance are exactly matched with the and the standards and regulations of UL and CSA. All fans conform to

ACmaxx / EC fans
size of fan. This guarantees the low noise that is typical for ebm-papst, the European Standard EN 60335 or EN 60950 plus those of the UL
even at high back pressure. (Underwriters Laboratories) and CSA (Canadian Standards Association).
With few exceptions, our DC fans are designed to meet the require-
Sturdy construction – in metal or plastic ments of protection class 3 / protection class voltage. AC fans are
Fans of all-metal construction: Sturdy and resistant. The housing is protection class 1. ebm-papst fans meet the highest requirements of
made of an aluminium alloy whereas the metal surfaces that are electrical safety. All design variants feature reverse polarity and locked
subject to corrosion are permanently protected by an impact- and rotor protection.

AC axial fans
abrasion-resistant electrophoretic baked enamel. This particular
version is highly recyclable. Fans with fibreglass-reinforced plastic Quality in detail
housing and impeller: Excellent stability and low weight distinguish It is in the important details where the motto "made by ebm-papst"
this highly efficient fan concept. Combinations of metal housing and comes into its own: Consistent adherence to development and design
plastic impeller unite the advantages of both types of design. processes and a targeted commitment to quality along the entire process
chain are the foundation for the fans' above-average service life.
Product images 100.000 hours and above are now possible. AC centrifugal fans
The dimensioned drawings and product photos that appear in the The no-compromise ebm-papst quality assurance spans over all
catalogue are for orientation purposes and may differ in some details process levels – from the choice of materials and the use of carefully
from the actual product design. selected, certified suppliers, from the production of parts up to final
assembly. These details combine to result in reliable fan products with
Product liability an above-average service life.
Motors and fans from ebm-papst are components intended for proper
installation. The customer bears responsibility for the overall end ErP guidelines
Accessories

product. All products with power consumption between 125 W and 500 kW are
subject to the European "Energy-related Products Directive" (ErP) for im-
proving energy efficiency, with the first stage coming into force from 2013
and the second as of 2015. Thanks to ground-breaking GreenTech EC
technology, all of our fans and motors in these performance classes
already exceed the ErP Directive today.
Representatives
2016-01

9
Tailor-made to meet your special requirements

Practice-oriented: Fans – customised and intelligent

ebm-papst has always developed customer-specific intelligent fans which meet the exact requirements of the application. We provide a wide range of
standard fan types, in many sizes and designs; with intelligent motor features, monitoring and control functions as well as special designs for use under
extreme conditions. They are all based on the standard type fans which you will find in this catalogue. Special fan types for your application can be
produced in economical batch sizes. Our expert engineers will assist you in selecting the right configuration.
2016-01

10
Information
DC axial fans
Innovation at its best: The main applications are units which demand load-dependent
Vario-Pro® with “intelligence inside”. Its programmed intelligence individual speed profiles or systems with stand-by minimum cooling
thanks to customer-specifically configured software modules makes requirements and varied speed increase at varying power peaks.

DC centrifugal fans
the cooling of electronics even more economical and flexible. For
example, temperature-dependent speed profiles are possible with a “Electronic tachometer” thanks to sensor signal
number of freely selectable interpolation points. External speed Do you wish to be informed about the current fan speed at all times?
settings and a variety of combinable alarm and tachometer functions ebm-papst has fans with an integrated “electronic tachometer” which
can also be programmed. The digital motor management achieves registers the actual value of the fan speed. Via an integrated sensor,
high control accuracy. the fan generates speed-dependent signals which can be directly

DC fans - specials
utilised. Depending on the number of poles of the motor, 2, 3 or 6
Higher degree of protection for every type of application pulses per revolution are generated.
ebm-papst provides, on request, many fan series in versions which
conform to the requirements of degree of protection IP 54 and IP 68: Alarm signal for more safety
Their stator and all electrical components are fully encapsulated. If your application requires monitored fan operation, in addition to
Stainless steel ball bearings can be used for operation in particularly speed monitoring, ebm-papst also provides a multitude of varying
aggressive media and use under extreme environmental conditions, alarm signals. Depending on the type of fan in question, the signal

ACmaxx / EC fans
thus providing additional reliability. is either static, already evaluated or interface-compatible.
The alarm signal output provides reliable longterm monitoring and
Virtually everything is possible a status signal if critical operating conditions evolve.
Regardless of your cooling and ventilation tasks, we develop the right
solution and what is more, the most economical one. Based on the fans S-Force
listed in this catalogue, well over 4000 different versions are available. The new measure of things!
When you need to provide extremely fast, powerful and efficient

AC axial fans
Temperature-controlled fans cooling for electronic components of all kinds, the generation of
Fans with temperature-controlled speed have particularly quiet cooling S-Force high-performance fans finishes first: in air performance,
characteristics. Thanks to integrated IC technology, they adapt their pressure build-up and technology. Extremely efficient drives and
speed to the current cooling requirements, which results in a drastic optimised aerodynamics form the core technology of the S-Force fans,
reduction of noise in most operating modes. A temperature sensor which we offer in both an axial and brand-new centrifugal model.
provides the fan with thermal information: either externally via a single
lead or integrated into the hub of the fan. S-Panther AC centrifugal fans
S-Panther power delivered quietly. Wherever there is need for power
Speed setting via interfaces and reduced noise, fans from the S-Panther range are the right
With a wide range of DC fans with separate control input, ebm-papst solution. A strong pressure saddle curve at optimum air flow
provides an alternative to the NTC-controlled types of fans. They are provides the power of a real big cat.
especially suitable for systems and units which already have standard
interfaces for varying speed via internal switching and control circuits.
Accessories
Representatives
2016-01

11
Optional special versions
(see chapter DC fans - specials)

In the catalogue, a text box in the upper right corner provides infor- max. 44 m /h 3
DC axial fans
mation on the special designs which are technically possible in 60 x 25 mm

the fan range. – Material: Housing: GRP1) (PBT) – Possible special versions:
(See chapter DC fans - specials)
Impeller: GRP1) (PA)
– Direction of air flow: Exhaust over struts - Speed signal
Please note that these special versions are not possible for all voltages – Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Alarm with limit speed
and speeds, and not in all combinations.The special versions are – Highlights:
TR 64
Developed for applications with
- External temperature sensor
- PWM control input
demanding environmental - Analog control input
designed for specific customers and projects and are not usually requirements - Humidity protection
– Mass: 70 g - Salt fog protection
available off the shelf. - Degree of protection: IP 54 / IP 68

Possible special designs are depicted on the catalogue page.

m3 cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

40 23,5 12 6 33 5,2 1,8 5 900 -20...+70 85 000 / 42 500 142 500


6 44 25,9 12 1 35 5,4 1,5 6 300 -20...+70 85 000 / 42 500 142 500

40 23,5 24 1 34 5,1 1,6 5 900 -20...+70 85 000 / 42 500 142 500


Speed signal /2, /12 Analog control
58 input
34,1 24 1 44 6,1 3,2 8 500 -20...+70 75 000 / 37 500 127 500
58 34,1 24 1 44 6,1 3,2 8 500 -20...+70 75 000 / 37 500 127 500
The fan uses a separate wire to output information about its speed, The speed of44the25,9fan48can
4
be 35changed
5,4
via
1,8
a6 300control
-20...+70
voltage. This control
85 000 / 42 500 142 500

and thus about the speed of the rotor. For technical details, please voltage is applied to a specially provided wire. For technical details,
refer to page 168 ff. please refer to page 179.

Go- / NoGo-alarm /37, /39 Multi-option control input


The fan uses a separate wire to output a static signal when it is The fan has a control input that the user can trigger either using a
stationary, thus providing information about whether or not the rotor PWM signal, an analog signal or a resistor. For technical details, please
is turning. For technical details, please refer to page 175 f. refer to page 180.

Alarm with limit speed /17, /19 Humidity protection


t
If one of the speeds defined in the fan electronics is not met, the fan Protection for the fan's electronics against moisture and condensation.
conveys via a static signal that the set limit speed has not been met. For technical details, please refer to page 181.
For technical details, please refer to page 172 ff.
Degree of protection IP 54* / IP 68*
Protection of motor and PCB board against splashed water and
External temperature sensor
humidity. For technical details, please refer to page 181.
A NTC resistor (negative temperature coefficient) is attached to the
fan via a separate wire and the fan changes its speed depending Salt fog protection
on the temperature on the NTC. For technical details, please refer to Protection of fan against the damaging effects of salt fog. For technical
page 178. details, please refer to page 181.

Internal temperature sensor Direction of rotation


In this case, the NTC is integrated into the fan and the fan changes its On many variants, the direction of rotation can be changed via a
speed depending on the temperature at the NTC. For technical details, control input.
please refer to page 178.

PWM control input


The speed of the fan can be changed via a pulse-width-modulated
signal. This signal is applied to a specially provided wire. For technical
* IP = International degree of protection marking
details, please refer to page 179.
2016-01

12
Information
Types of fans and their function

DC axial fans
Axial fans:
High air flow with medium to relatively high pressure build-up
The air flow in axial fans, whose impeller is similar to that of a

DC centrifugal fans
propeller, is conducted to a great extent parallel to the axis of rotation,
in other words in the axial direction. Axial fans with free air delivery
at zero static pressure have the lowest power input that rises with
increasing back pressure. Axial fans for cooling of electronic equip-
ment are mostly equipped with external housing and an electric motor
integrated into the fan hub. This compact design allows space-saving

DC fans - specials
accommodation of all devices; the flange is equipped with mounting
holes.

Diagonal fans:
High flow rate at relatively high pressure build-up
At first glance diagonal fans only differ slightly from axial fans. Intake

ACmaxx / EC fans
is axial, whereas exhaust is diagonal. Due to the conical shape of the
wheel and housing, the air is pressurised more. In direct comparison
with axial fans of the same size and comparable performance, these
fans are distinguished by the lower operating noise at high pressures.

AC axial fans
Centrifugal fans:
High pressure build-up at limited flow rate
Many of the cooling problems that occur can be optimally solved by
axial and/or diagonal fans. If, for example, the required cooling air
has to be conducted at an angle of 90° or if even high pressure is
necessary, centrifugal fans are more effective. For your application,
ebm-papst offers not only complete centrifugal fans but also AC centrifugal fans

motor/impeller combinations without external housing.

Tangential fans:
High flow rate at low pressure
Tangential fans are used above all-, for large-surface air flow in
Accessories

devices. The air flows through the roller-shaped impellers twice in the
radial direction: in the intake area from the outside to the inside and in
the outflow area from the inside to the outside. Whirls form in the roller
due to the vanes which guarantee a steady flow of air through the
impeller.
Representatives
2016-01

13
Selecting the correct fan

1. Dissipated energy 3. Required cooling air flow


A large amount of the energy consumed by electrical and electronic • In the below diagram a horizontal line is drawn from the dissipated
devices is converted into heat. In selecting the correct fan, therefore, enery to intersect with the selected ΔT line.
it is important to determine the dissipated energy that must be • Read down from this point to obtain the required value for the
removed. The electrical power consumption of the unit to be cooled, cooling air flow. The diagram is based on the following formula:
often represents a suitable value for this purpose. PV
qV =
C PL . ρ L . ΔT
2. Permissible temperature rise
The air flow which the selected fan is required to generate, is 4. Optimum operating range
determined by the dissipated energy and the permissible rise (ΔT) The required fan, however, must also be able to deliver a suitable static
of the cooling air flow (from entry to exit of the device to be cooled). pressure increase Δpf,
= abzuführende in order toinforce
Verlustleistung [W] the cooling air through the
The max. allowable ΔT depends greatly on the temperature sensitivity device. A fan must therefore be selected that provides the required air
of the individual device components. flow performance within its optimum operating range (see also the air
ΔT = 5K means e.g. that the average air flow leaving the device to performance curves under technical data).
be cooled may only be 5°C warmer than the ambient temperature (a
large volume of air is required for this purpose). A lower air flow rate 5. Fan selection
is sufficient if a higher temperature difference (e.g. ΔT = 20K), can If the requirements of an application are fulfilled by more than one fan,
be tolerated. the noise level, space requirements, economy and ambient conditions
will assist in making the final choice.

Definitions
P V = amount of heat to be dissipated in [W] ρ L = air density in [kg/m3 ]
C PL = specific heat capacity of air in [J/kg/K] ρ L = 1,2 kg/m 3
C PL = 1010 [J/kg/K] ΔT = T1-T2 temperature difference in [K] between inlet and outlet
2016-01

14
Information
Fan installation

DC axial fans
Intake or exhaust side installation
Under ideal conditions, the operating point is represented as the Baffle
intersection between the fan and loss curves, regardless of whether

DC centrifugal fans
the fan is positioned at the air intake or exhaust side of the device. In
addition to ensuring the required flow rate, several additional aspects
Multidirectional intake,
must be considered for determining an appropriate fan concept.
laminar currents
The intake air currents of a fan are mainly laminar, comprising nearly
the entire suction area. By contrast, the exhaust air of a fan is gener-
ally turbulent, while it flows on a preferred direction, e.g. axial for an

DC fans - specials
axial fan. The turbulences of the exhaust intensify the heat transfer
from components within the air currents, so that mounting the fan at
the air intake side of the device is recommended for cooling and heat-
ing. Mounting the fan at the device intake is also advantageous be- Unidirectional exhaust,
turbulent
cause the fan will not be subjected to the dissipated heat of the device.
Therefore, it operates at low ambient temperatures and has a higher
life expectancy.

ACmaxx / EC fans
Information on installation
When a fan is operated for the first time in an application, the user may Accident prevention
have noticed that the flow rate in the device was lower than expected. The turning rotor and the high speeds that are sometimes involved
What is the reason for this? mean that our fan products carry an inherent risk of injury. They
• The values stated in this catalogue were determined under optimum, may only be operated after correct installation and with suitable

AC axial fans
constant and comparable measurement conditions. protective facilities (e.g. with a guard grille). More information can
• Ideal mounting conditions under which free air intake and exhaust be found in the internet at: www.ebmpapst.com/safety
are present are seldom feasible in practice. Quite frequently the fans
must be mounted in close proximity to other components or cabinet
panels. As a consequence, the intake and exhaust currents may be
restricted, causing the air flow to diminish and the noise level to
increase. Fans are particularly sensitive to obstructions which are AC centrifugal fans
positioned directly in front of the output cross section as they often
cause an increase in tonal noise.

Our advice: The distance between the fan and adjacent components
should be at least equal to the installation depth of the fan.
Accessories
Representatives
2016-01

15
Connection instructions for S-Force fans

Special features of S-Force fans


The S-Force series is the most powerful product series on the market.
S-Force stands for the highest innovation in motor technology, fluid
mechanics and electronics. The one-of-a-kind power density of the
products requires special attention to the application at the customer's
facility.

Service life
Due to the high currents in the fans, the load on the electrolyte
capacitors is greater, which reduces the service life of the capacitor.
As a larger or additional capacitor cannot be housed in the fan, the
capacitor must be housed in the supply line.
If the power pack of the application has a corresponding capacitor, in
some cases it may be possible to omit the external capacitor.
Recommended measure: Additional external capa-
citor (thus must be installed as close to the fan as
possible < 30 cm).
Fan Capacitor
required

S-Force axial Recommended capacitors


8200 / 3200 JH3-JH4 no We recommend using the following capacitors from Rubycon:
4100 NH3 / NH4 / NH5 / NH6 no 24 VDC:
4100 NH7 / NH8 yes 50 ZL 680 mF; 12,5 mm x 30 mm or
5300 / 5300 TD no 50 ZLH 680 mF 12,5 mm x 30 mm
6300 / 6300 TD / DV 6300 no
2200 FTD no 48 VDC:
100 YXG 470 mF; 16 mm x 35,5 mm or
S-Force centrifugal 100 ZLH 470 mF 16 mm x 31,5 mm
RET 97 TD yes
RER 120 TD yes Other capacitors with equal or greater capacitance and equal or lower
RER 133 TD no serial resistance can also be used.
RER 160 NTDHH / RG 160 NTDHH yes ebm-papst St. Georgen offers the following capacitors ex stock:
REF 175 TD no 24 VDC: 1000 mF / 50 V, 16 mm x 25 mm
RER 175 TD no Art. No.: 992 0345 000 (LZ 354)
RER 190 TD / RG 190 TD no
RER 220 TD / RG 220 TD no 48 VDC: 680 mF / 100 V, 18 mm x 40 mm
RER 225 TDM / RG 225 TDM no Art. No. : 992 0355 000 (LZ 355)
RER 225 TD / RG 225 TD no
2016-01

16
Information
m

Service life Housing: GRP1


Impeller: GRP1
-
- Go- / NoGo-alarm
Via single wires AWG 22, - Alarm with limit speed

DC axial fans
TR 64 - External temperature sensor
– Developed for applications with - PWM control input
demanding environmental - Analog control input
requirements - Humidity protection
– 7 - Salt fog protection
- Degree of protection: IP 54 / IP 68

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Service life data from ebm-papst St. Georgen

Nominal speed
Ball bearings

Input power
Our fans catalogue gives three different values for the service life of each product. The first

DC centrifugal fans
Curve
column usually states the service life L10 at 40°C. the second column usually states
m 3
theVDCservice
cfm VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

life L10 at Tmax. Exceptions are marked in the column headings. The third column
40 states
23,5 the
12 new
6 33 5,2 1,8 5 900 -20...+70 85 000 / 42 500 142 500 ➀
44 25,9 12 1 35 5,4 1,5 6 300 -20...+70 85 000 / 42 500 142 500 ➁
value, life expectancy L10IPC (40 °C). 40 23,5 24 1 34 Example
5,1 of the
1,6 service
5 900 life figures85on
-20...+70 000 /the catalogue
42 500 142 500 page.
58 34,1 24 1 44 6,1 3,2 8 500 -20...+70 75 000 / 37 500 127 500
58 34,1 24 1 44 6,1 3,2 8 500 -20...+70 75 000 / 37 500 127 500

44 25,9 48 4 35 5,4 1,8 6 300 -20...+70 85 000 / 42 500 142 500

DC fans - specials
Service life L10 (40 °C) and L10 (Tmax) Summary:
The values given in the first two columns have been derived from The life span calculations have been carried out to the best of our
intensive, in-house service life endurance tests, in which our products knowledge and are based on experience gained by ebm-papst. The
are operated in various positions at 40°C and 70°C until they fail. A fan specified L10 (40 °C), L10 (Tmax) and L10IPC (40 °C) values all allow
is deemed to have failed when it deviates from its defined air flow and statements to be made about the theoretical calculated service life

ACmaxx / EC fans
speed values, or when the operating noise becomes noticeable. Such under certain assumptions. The values determined here are extra-
t

tests can take several years before a representative number of failures polations from our own service life tests and from statistical variables.
have been registered, and even today, some fans are still in the In the respective customer applications, different influences may occur
process of endurance testing, even though they began tests in the which cannot be included in the calculations due to their complexity.
1980s. These fans are proof of the legendary "made by ebm-papst" The service life information is explicitly not a guarantee of service life,
reliability. but strictly a theoretical quality figure.
Test results are presented in a diagram and the service life of the
product L10 at the temperature tested is determined on the basis of

AC axial fans
Fans in an endurance test cabinet at
the Weibull distribution. ebm-papst St. Georgen.
These tests have given us years of experience in the way various 1500 fans are operated in tempera-
ture cabinets until they fail.
design parameters and temperatures can affect the service life of a
product. Data for service life at various temperatures for new products
can be stated with a very high degree of precision on the basis of

AC centrifugal fans
tests, product specifications and of commonalities in the design of
the product.

New: Life expectancy L10IPC (40 °C)


The new third service life column states the expected service life
L10IPC . This information is based on the international norm IPC 9591.
Again here, the foundations for the service life values are our service
life endurance tests at high ambient temperatures. The service life at
Accessories

temperatures below the test temperatures is calculated using fixed


factors. This method produces much higher service life values,
Example of the influence of factors from
especially at room temperature (see diagram on right). various manufacturers on the expected
Bathtub curve and Weibull distribution. service life.
Representatives
2016-01

17
Definitions

Nominal voltage (Volts) generation but not the flow rate. The pressure Input power [Watts]
The voltage at which the nominal values generated at other air densities may be Input performance of the fan motor when
(the tabular values listed in this catalogue) were estimated with the formula Dr2 = Dr1 (r2 / r1). operating free blowing at nominal voltage.
determined. The fan operation for DC fans is not The nominal speed values, air flow and power Depending on the operating condition in the
limited to the nominal voltage. Fan speed and input listed in the table were measured in free application, the power input may be higher.
fan performance can vary according to the air operation with horizontal shaft at an ambient
permissible voltage range that is specified on temperature of 20 +5 °C, air density Temperature range [°C]
the nameplate of each fan. Be aware here that r = 1.2 kg/m3 after a warm-up period of 5 min. The permissible ambient temperature range
this is not a pulsed or modulated DC voltage. within which the fan can be expected to run
Optimum operating range continuously.
Frequency (Hz) During operation, fans are required to produce
ebm-papst AC fans are made for operating an air flow with a simultaneous increase of Service life [h]
frequencies of 50 Hz or 60 Hz. Their technical pressure. These operating conditions are Service life L10 at 40 °C and Tmax
data alter accordingly. described in the section “Optimum Operating Standard figures for service life at ebm-papst.
Range”. The optimum operating range is These two temperatures are based on intensive,
Air flow [m3/h]
therefore always indicated in this catalogue in in-house endurance tests and on the experience
The air performance of the fan in free air
the shaded area. In this range the fans operate more than 60 years developing fans.
operation, i.e. the fan blows into the free space
best with respect to efficiency and noise level.
without static pressure build-up. Life expectancy L10IPC (40 °C)
Within this optimum operating range the noise
Information calculated in line with the norm
level only fluctuates insignificantly.
Fan curves IPC 9591. Data based on the internal expected
The fan curves are determined in accordance service life at 70°C, more optimistically
Noise [dB(A), Bel(A)]
with DIN ISO 5801 specifications on a extrapolated to 40°C.
1. Sound pressure level – dB(A)
dual-chamber test stand with intake-side
Noise ratings of the fan in free air operation, i.e. We expressly state that none of the
measurement. This measurement technique
at maximum flow rate. information or data in this catalogue is
closely approximates the operating conditions
to be construed as a guarantee or warranty
experienced in typical applications for fans 2. Sound power level – Bel(A) / dB(A)
of properties.
and yields realistic performance curves. The Extent of the overall sound radiation of the fan.
curves apply to an air density of r = 1.2 kg/m , 3 The sound power level is determined in the
Unit conversion
corresponding to an air pressure of 1013 mbar optimum operating range.
Air flow Pressure
at 20 °C. Variations in air density affect pressure 1cfm = 1,7 m3/h 1Pa = 1x10-5 bar
PAPST Sintec® sleeve bearings
1l/s = 3,6 m3/h 1 inch H2O = 249 Pa
A particularly efficient bearing system with
1l/min = 0,06 m3/h 1 mm H2O = 9,81 Pa
excellent qualities:
– Very precise, large sintered bearings
– Low running noise
– High service life expectancy
Subject to technical alterations.
– Insensitive to shock and vibration Our products are not designed for use in the aerospace
industry!
German and international patents, registered designs and
Ball bearings utility models.
Precision ball bearings for particularly high ebm-papst is a registered trademark of ebm-papst Mulfingen
GmbH & Co. KG.
ambient temperatures and high service life
PAPST, SINTEC, VARIOFAN and Vario-Pro are registered
expectancy. trademarks of ebm-papst St. Georgen GmbH & Co. KG.
2016-01

18
Information
Standard test equipment to test the
fan characteristics

DC axial fans
Pressure-flow rate:

Blow-down test facility acc. ISO 5801

DC centrifugal fans
Flow rate measurement

DC fans - specials
aux. fan
test object

meshes

P∞ Pst

ACmaxx / EC fans
T∞

Sound power level pressure-flow rate:

AC axial fans
Outlet side regulated test rig in semi-anechoic chamber according to ISO 10302

Pst
discharge
throttle
test object

AC centrifugal fans

10 microphones (r = 2 m)
P∞
T∞
Accessories
Representatives
2016-01

19
Type code

3-digit DC axial fan e.g. 412 FM

Housing dimensions (W x H x D) Options (various versions possible)


Value Edge dimensions (W x H) Installation depth (D) Operating voltage A Analog speed control input (input voltage: 0…5 / 0...10 V DC)
2 25 x 25 mm 8 mm Value Nominal voltage D Reinforced flange corners with through-holes (Series 44xx F)
4 40 x 40 mm 10 / 20 / 25 / 28 mm 2 12 V Constant speed control independent from operating voltage
5 50 x 50 mm 15 mm 4 24 V E Economy fan with round flange
6 60 x 60 mm 15 / 25 / 32 mm 5 5V F Flat construction / frequency-modulated signal
7 70 x 70 mm 15 mm 8 48 V G Sleeve bearing
H High speed
HH Further increased speed
H3-H8 Additional further increased speeds

412 FM
(H8 - maximum fan speed)
I Integrated temperature sensor (NTC behaviour, i.e. thermistor)
J Jet characteristic / rigid curve
L Low speed
M Medium speed
ML Between low and medium speed
Motor and housing version N Standard or basic speed (only DC fans)
Value Version O Multi-option speed control input (analog or PWM signal)
1 4xx fan, 10 / 20 / 25 / 28 mm (D) P PWM speed control input (pulse-width modulated signal)
1 6xx fan, 15 / 25 / 32 mm (D) R Moisture protection coating
2 25 / 28 mm (D) Circuit board and winding (IP 20), optional stainless steel ball bearing
3 63x fan, 25 mm (D) S Speed signal (additional wires for hall signal, obsolete technology)
5 2xx fan, 8 mm (D) T External temperature sensor (NTC behaviour, i.e. thermistor)
TD Turbo drive (extremely powerful 3-phase motor)
U Environmentally friendly fan (min. IP 54)
V / VP VARIOFAN
W Additional wires (standard length 310 mm)
X Mounting bore hole 3.7 mm
-xxx Variant number

4-digit DC axial fan, e.g. 4312 GM

Housing dimensions (W x H x D) Options (various versions possible)


Value Edge dimensions (W x H) Installation depth (D) A Analog speed control input (input voltage: 0…5 / 0...10 V DC)
2 Ø 220 x 200 mm 51 mm D Reinforced flange corners with through-holes (Series 44xx F)
3 92 x 92 mm 25 / 32 / 38 mm Connection type and direction of rotation Constant speed control independent from operating voltage
4 119 x 119 mm 25 / 32 / 38 mm Value Connection type Direction of rotation DV Diagonal Venturi fan
5 127 x 127 mm 38 mm 1 Wires, length = 310 mm E Economy fan with round flange
5 135 x 135 mm 38 mm 5 Wires, length = 310 mm F Flat construction / frequency-modulated signal
5 140 x 140 mm 51 mm 6 Plug, 2.8 x 0.8 mm Counter-clockwise (CCW) G Sleeve bearing
6 Ø 172 mm 51 mm 7 Plug, 2.8 x 0.8 mm Clockwise (CW) H High speed
6 Ø 172 x 150 / 160 mm 51 mm 8 Plug, 2.8 x 0.5 mm Counter-clockwise (CCW) HH Further increased speed
7 Ø 150 mm 38 / 55 mm 9 Plug, 2.8 x 0.5 mm Clockwise (CW) H3-H8 Additional further increased speeds
8 80 x 80 mm 25 / 32 / 38 mm (H8 - maximum fan speed)
I Integrated temperature sensor (NTC behaviour, i.e. thermistor)
J Jet characteristic / rigid curve
L Low speed

4312 GM
M Medium speed
ML Between low and medium speed
N Standard or basic speed (only DC fans)
O Multi-option speed control input (analog or PWM signal)
P PWM speed control input (pulse-width modulated signal)
R Moisture protection coating
Motor and housing version Operating voltage Circuit board and winding (IP 20), optional stainless steel ball bearing
Value Version Value Nominal voltage S Speed signal (additional wires for hall signal, obsolete technology)
1 38 mm (D) 2 12 V T External temperature sensor (NTC behaviour, i.e. thermistor)
2 38 mm (D) 4 24 V TD Turbo drive (extremely powerful 3-phase motor)
3 32 mm (D) 6 36 V U Environmentally friendly fan (min. IP 54)
4 25 / 38 / 51 mm (D) 8 48 V V / VP VARIOFAN
W Additional wires (standard length 310 mm)
X Mounting bore hole 3.7 mm
-xxx Variant number
2016-01

20
Information
Type code

DC axial fans
DC centrifugal fan e.g. RER 160-28/12 N

DC centrifugal fans
Options (various versions possible)
A Analog speed control input (input voltage: 0…5 / 0...10 V DC)
D Reinforced flange corners with through-holes (Series 44xx F)
Constant speed control independent from operating voltage
E Economy fan with round flange
F Flat construction / frequency-modulated signal
G Sleeve bearing
H High speed
HH Further increased speed
H3-H8 Additional further increased speeds
(H8 - maximum fan speed)

DC fans - specials
I Integrated temperature sensor (NTC behaviour, i.e. thermistor)
J Jet characteristic / rigid curve
L Low speed
M Medium speed
ML Between low and medium speed
N Standard or basic speed (only DC fans)
O Multi-option speed control input (analog or PWM signal)
P PWM speed control input (pulse-width modulated signal)
Type Housing and fan impeller versions R Moisture protection coating
Housing Impeller blade design Circuit board and winding (IP 20), optional stainless steel ball bearing
RE None Non-curved, no direction of rotation set S Speed signal (additional wires for hall signal, obsolete technology)

ACmaxx / EC fans
REF None Forwards/backwards-curved impeller blades, flat T External temperature sensor (NTC behaviour, i.e. thermistor)
RER None Backwards-curved impeller blades TD Turbo drive (extremely powerful 3-phase motor)
RET None Forwards-curved impeller blades U Environmentally friendly fan (min. IP 54)
RG Square Forwards/backwards-curved impeller blades V / VP VARIOFAN
RL Round Forwards-curved impeller blades W Additional wires (standard length 310 mm)
RLF Round Forwards/backwards-curved impeller blades, flat X Mounting bore hole 3.7 mm
RV Round Forwards-curved impeller blades Height fan impeller blade -xxx Variant number

RER 160 - 28 / 12 N

AC axial fans
Impeller diameter in mm Operating voltage
Value Nominal voltage
/12 12 V
/14 24 V
/18 48 V

AC centrifugal fans
Tangential blower e.g. QG 030-148/12

Housing dimensions (W x H)
Value Edge dimensions (W x H) Impeller length Total length
148 48 x 50 mm 148 mm 201 mm
Type Housing and fan impeller versions 198 48 x 50 mm 198 mm 258 mm
Housing Impeller blade design 303 48 x 50 mm 303 mm 363 mm
QG Round Compressor drum 353 48 x 50 mm 353 mm 413 mm
Accessories

QG 030 - 148 / 12
Impeller diameter in mm Operating voltage
Value Nominal voltage
/12 12 V
/14 24 V
Representatives
2016-01

21
Type code

4-digit GreenTech EC compact fans axial e.g. ACi 4420 HH

Housing dimensions (W x H x D) Options (various versions possible)


Value Edge dimensions (W x H) Installation depth (D) Operating voltage A Analog speed control input (input voltage:
1 Ø 98,5 mm 130 mm Value Nominal voltage Frequency Design 0…5 / 0...10 V DC)
3 92 x 92 mm 38 mm 0 115 / 230 V 50 / 60 Hz Wide voltage range input D Reinforced flange corners with through-holes (Series 44xx F)
4 119 x 119 mm 25 / 32 / 38 mm (85-265 V AC) Constant speed control independent from operating voltage
6 Ø 172 51 mm 1 115 V 50 Hz E Economy fan with round flange
8 80 x 80 mm 32 mm 2 230 V 50 Hz F Flat construction / frequency-modulated signal
G Sleeve bearing
H High speed
HH Further increased speed

AC i 4420 HH
H3-H8 Additional further increased speeds
(H8 - maximum fan speed)
I Integrated temperature sensor (NTC behaviour,
i.e. thermistor)
J Jet characteristic / rigid curve
L Low speed
Basic design Motor and housing version Bearing type and insulation class M Medium speed
Value Design Value Version Value Bearing type Insulation class ML Between low and medium speed
AC DC basic fan with 0 130 mm (D) 0 Ball bearing E N Standard or basic speed (only DC fans)
integrated AC/DC 1 51 mm (D) O Multi-option speed control input (analog or PWM signal)
power supply unit 2 38 / 51 mm (D) P PWM speed control input (pulse-width modulated signal)
ACi EC technology 3 32 mm (D) R Moisture protection coating
(electronics completely 4 25 / 38 mm (D) Circuit board and winding (IP 20), optional stainless
integrated) steel ball bearing
S Speed signal (additional wires for hall signal,
obsolete technology)
T External temperature sensor (NTC behaviour, i.e. thermistor)
TD Turbo drive (extremely powerful 3-phase motor)
U Environmentally friendly fan (min. IP 54)
V / VP VARIOFAN
W Additional wires (standard length 310 mm)
X Mounting bore hole 3.7 mm
-xxx Variant number

AC axial fan e.g. 3950 L

Housing dimensions (W x H x D) Options (various versions possible)


Value Edge dimensions (W x H) Installation depth (D) Operating voltage A Air intake via struts (attachment bore ø)
3 92 x 92 mm 25 / 38 mm Value Nominal voltage Frequency E Made by ebm-papst Mulfingen (6xxx, 7xxx range) or round flange
4 119 x 119 mm 25 / 32 / 38 mm 0 115 V 60 Hz H Speed signal
5 127 x 127 mm 38 mm 2 115 V 60 Hz 1 Impulses per 360 degrees (additional magnet sensor and hall sensor)
5 135 x 135 mm 38 mm 3 115 V 60 Hz L Low speed
5 140 x 140 mm 51 mm 4 115 V 50 Hz M Medium speed
6 Ø 172 mm 51 / 52 mm 5 230 V 50 Hz N Air intake via struts (ø mounting bore hole)
7 Ø 150 mm 55 mm 6 115 V / 230 V 50 Hz / 60 Hz R Moisture protection coating
7 Ø 150 x 172 mm 38 mm 7 230 V 50 Hz Circuit board and winding (IP 20), optional stainless steel ball bearing
8 80 x 80 mm 38 mm 8 230 V 60 Hz S Integrated temperature switch
9 119 x 119 mm 25 mm 9 230 V 60 Hz T Assembly bracket
U Environmentally friendly fan (min. IP 54)
V Air exhaust via struts
W Additional wires (standard length 310 mm)

3950 L
X Mounting bore hole 3.7 mm
-xxx Variant number
Z Air exhaust via struts, reinforced flange corners with through-holes

Motor and housing version Bearing type and insulation class


Value Version Value Bearing type Insulation class
4 Shaded-pole motor, 55 mm (D) medium speed 0 Sleeve bearing E
5 Shaded-pole motor, 38 mm (D) medium / high speed 5 Ball bearing E
6 Shaded-pole motor, 38 mm (D) high speed 6 Ball bearing F
7 Shaded-pole motor, 38 mm (D) with assembly bracket 8 Ball bearing E
8 Shaded-pole motor, slow / medium speed
9 Shaded-pole motor, 25 / 38 mm (D)
2016-01

22
Information
Type code

DC axial fans
AC centrifugal fan e.g. RER 160-28/56 S

Options (various versions possible)

DC centrifugal fans
A Intake via bars
E Made by ebm-papst Mulfingen (6xxx, 7xxx range) or round flange
H Speed signal
1 Impulses per 360 degrees (additional magnet sensor and hall sensor)
L Low speed
M Medium speed
N Air intake via struts (ø mounting bore hole)
R Moisture protection coating
Type Housing and fan impeller versions Circuit board and winding (IP 20), optional stainless steel ball bearing
Housing Impeller blade design S Integrated temperature switch
RE None Non-curved, no direction of rotation set T Assembly bracket

DC fans - specials
REF None Forwards/backwards-curved impeller blades, flat U Environmentally friendly fan (min. IP 54)
RER None Backwards-curved impeller blades V Air exhaust via bars
RET None Forwards-curved impeller blades W Additional wires (standard length 310 mm)
RG Square Forwards/backwards-curved impeller blades X Mounting bore hole 3.7 mm
RL Round Forwards-curved impeller blades -xxx Variant number
RLF Round Forwards/backwards-curved impeller blades, flat Z Air exhaust via bars, reinforced flange joints with through-holes
RV Round Forwards-curved impeller blades Height fan impeller blade

RER 160 - 28 / 56 S

ACmaxx / EC fans
Impeller diameter in Operating voltage
Value Nominal voltage Frequency
/00 115 V 60 Hz
/06 115 V 60 Hz
/50 230 V 50 Hz
/56 230 V 50 Hz

AC axial fans
DC centrifugal fan e.g. R3G 190-RN 38-01
Note: This type code specifies fans from ebm-papst Mulfingen and can be used to clearly identify
and order them:

Type Housing and fan impeller versions


AC centrifugal fans
A Axial fan
S Axial fan with guard grille
W Axial fan with wall ring
V Axial combination
R Centrifugal fan, single inlet
G Centrifugal blower, single inlet (with scroll housing) Key for Key for
B Centrifugal fan, dual inlet
G Centrifugal blower, dual inlet (with scroll housing) mechanical mechanical
K Centrifugal combination Impeller diameter in mm design variants

R3G 190 - RN38 - 01


Accessories

Number of poles (AC) Motor type Key for


2 2-pole D Three-phase motor electrical
E Single-phase motor with
design
Number of cores (DC/EC) capacitor
1 1-phase/core G DC/EC motor
Representatives

3 3-phase/core
2016-01

23
2016-01

24
DC axial fans

DC axial fan overview


DC axial fans / DC diagonal fans

25
31
27

2016-01

Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans DC axial fans Information
DC axial fans

Technical information

Range of fans Voltage range


ebm-papst offers you the widest full product line of DC axial and dia- Many of our DC fans can be operated on voltages that are up to 50%
gonal fans: From 25 mm to 280 mm in size. Every single type of fan can lower and 25% higher than their nominal voltage (see Voltage range in
be optimally integrated in the respective device concept. The highly the technical tables). This enables the air performance to be adapted to
economical brushless motor technology of these fans provides a unique the cooling requirements and allows the noise to be reduced, even if the
variety of intelligent innovations that can be realised today at prices that fan does not have a control input.
would have been unthinkable just a few years ago.
Closed-loop speed control and monitoring
Electronic protection against reverse polarity Closed-loop speed control and function monitoring are becoming in-
ebm-papst DC fans have electronically commutated drives with electronic creasingly important in many applications. ebm-papst offers many fans in
protection against reverse polarity. The electronics are conveniently loca- the standard design with a control input and open collector speed signal.
ted in the fan hub.
S-Force
Product life expectancy The new S-Force fans with their extremely high blower capacity of up to
A distinctive feature of DC fan technology is the convincingly high product 1100 m3/h and pressure build-up of up to 1400 pascals are capable of
life expectancy. Thanks to the excellent efficiency of the brushless drives, dealing with the extreme heat load. If needed, these fans can produce up
the thermal load of the bearings is reduced, thus considerably increasing to 100% more output under full load and they work with a much broader
the life expectancy of the fans. delivery bandwidth than current models. This makes them ideal for equip-
ment and systems with a high density of components. Thanks to intelli-
Degree of protection gent motor features, they can be individually adapted for any application.
DC fans with sleeve and ball bearings are powered by class E insulated S-Force fans are available in 5 standard dimensions.
motors. All ebm-papst fans conform to the requirements of degree of
protection IP 20. Fans conforming to IP 54 / IP 68 and special degrees of S-Panther
protection are also available. S-Panther power delivered quietly. Wherever there is need for power
and reduced noise, fans from the S-Panther range are the right
solution. A strong pressure saddle curve at optimum air flow
provides the power of a real big cat.
2016-01

26
Information
Axial fans for DC operation
Overview of air performance

DC axial fans
Dimensions

Air flow
Series

Page
10 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 2500
mm m3/h
c 25 x 8 250 2,3...4,6 31
c

DC centrifugal fans
40 x 10 400 F 6...9 32
c 40 x 20 400 10...13,5 33
c 40 x 28 420 J 24...38 34
c 50 x 15 500 F 11...20 35
c 60 x 15 600 F 19...33 36
c 60 x 25 620 21...67 37
c 60 x 25 630 40...44 38
c 60 x 25 600 N 21...56 39
c 60 x 25 600 N VARIOFAN 16...41 40
c 60 x 32

DC fans - specials
600 J 70...82 41
c 70 x 15 700 F 28...44 42
c 80 x 25 8450 32...117 43
c 80 x 25 8400 N 33...79 44
c 80 x 25 8400 N VARIOFAN 20...58 45
c 80 x 32 8300 32...80 46
c 80 x 38 8200 J 132...222 47
c 92 x 25 3400 N 61...102 48
c 92 x 25 3400 N VARIOFAN 44...84 49
c 92 x 32

ACmaxx / EC fans
3300 N 56...133 50
c 92 x 38 3200 J 130...280 51
c 92 x 38 3250 J 145...270 52
c 119 x 25 4400 F 94...170 53
Ø 127 4400 F 91 NEW 54
c 119 x 25 4400 FN 200...225 55
c 119 x 32 4300 95...204 56
c 119 x 32 4300 VARIOFAN 65...170 57
Subject to alterations

10 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 2500

AC axial fans
m3/h

AC centrifugal fans
Accessories
Representatives
2016-01

27
Axial fans for DC operation
Overview of air performance
Dimensions

Air flow
Series

Page
mm m3/h 10 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 2500

c 119 x 38 4400 100...285 58/59


c 119 x 38 4100 N 160...237 60
c 119 x 38 4100 NHH..NH6 260...440 61
c 119 x 38 4100 NH7..NH8 500...570 62
c 119 x 38 DV 4100 280 63
c 127 x 38 5200 N 187...340 64
c 127 x 38 DV 5200 270...320 65
c 135 x 38 5100 N 260 66
c 140 x 51 5300 340 67
c 140 x 51 5300 TD 410...670 68
Ø 150 x 38 7100 N 308...360 69
Ø 150 x 55 7200 N 360 70
172x150x51 6400 350...480 71
172x150x51 6400 TD 90...900 72
172x160x51 DV 6400 530 73
172x160x51 DV 6400 TD 100...680 74
172x160x51 6300 TD 710...930 75
Ø 172 x 51 6300 N 540...685 76
Ø 172 x 51 6300 NTD 970...1030 77
Ø 172 x 51 6300 395...545 78
Ø 172 x 51 6300 TD 600...930 79
Ø 172 x 51 DV 6300 TD 630...1100 80
220x200x51 2200 FTD 790...1220 81
c 225 x 80 K1G 200 1020...1245 82
c 225 x 89 K3G 200 725...905 84
Ø 250 W1G 250 2070 86
Ø 300 *1G 300 2320...2345 88
Subject to alterations

10 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 2500
m3/h
2016-01

28
Information
Axial fans for DC operation
Overview of technically feasible designs

ings

ation
re se r
bear

nsor
nso

f rot
put
re se
/ball

rol in

DC axial fans
spee

ut
ings

tion
n
eratu

t
eratu

tion
ectio
l inp
larm

Analo trol inpu

cont
bear

direc
limit

rotec
temp

ntro

prot
emp
Go-a
CSA

tion
igna
ns

eve

with

rsible
g co

fog p
con
ensio

= 54
idity
nal t
c sle

i-op
/ No

rnal
, UL,

ds

Alarm

PWM

IP 68

Reve
Page
Hum
Spee

Mult
Sinte

Inter
Exte

IP >
Dim

Salt
Go-
VDE Please note that these special versions are not possible for
Axial fans
all voltages and speeds, and not in all combinations.
mm Series OPTIONAL P.
c 25 x 8
The special versions are designed for specific customers
250 ja • – – – – – – – • – – – – 31

DC centrifugal fans
c
and projects. As a rule they are not available off the shelf
40 x 10 400 F ja • • – – – – – – • – – – – 32
c
and are tied to minimum volumes.
40 x 20 400 ja • • – – – • – – • – – – – 33
c 40 x 28 420 J ja • • – • – • – – • – – • – 34
c 50 x 15 500 F ja • • – – – • – – • – – – – 35
Please consult your customer support representative
c 60 x 15 600 F ja • • – – – • – – • – – – – 36
about the feasibility of your special variant.
c 60 x 25 620 ja • • • • • • • – • – – – – 37
c 60 x 25 630 ja • • • • – • • – • • • • – 38
c 60 x 25 600 N ja / • • – – – – – – • • • – – 39

DC fans - specials
c 60 x 25 600 N VARIOFAN ja / • • – • • – – – • – – – – 40
c 60 x 32 600 J ja • • – • – • • – • – – – – 41
c 70 x 15 700 F ja • • – – – – – – • – – – – 42
c 80 x 25 8450 ja / • • • • • • • – • – – – – 43
c 80 x 25 8400 N ja / • • • • • • • – • • • – – 44
c 80 x 25 8400 N VARIOFAN ja • • – • • – – – • – – – – 45
c 80 x 32 8300 ja • • • • • • • – • • • • – 46
c 80 x 38 8200 J ja • • • • • • • – • • – – – 47

ACmaxx / EC fans
c 92 x 25 3400 N ja / • • • • • • • – • • • – – 48
c 92 x 25 3400 N VARIOFAN ja • • – • • – – – • – – – – 49
c 92 x 38 3300 N ja • • – • • • • – • • • • – 50
c 92 x 38 3200 J ja • • • • • • • – • • • – – 51
c 92 x 38 3250 J ja • • – • • • • – • • • • – 52
c 119 x 25 4400 F ja / • • • • • • • – • – – – – 53
NEW Ø 172 4400 F ja • • • • • • • – • – – – • 54
c 119 x 25 4400 FN ja • • • • • • • – • – – – – 55

AC axial fans
c 119 x 32 4300 ja / • • • • • • • – • • • • – 56
c 119 x 32 4300 VARIOFAN ja • • • • • • • – • – – – – 57
Subject to alterations

– not yet available Sleeve bearings


• available Ball bearings

AC centrifugal fans
Accessories
Representatives
2016-01

29
Axial fans for DC operation
Overview of technically feasible designs

ings

ation
re se r
bear

nsor
o
sens

f rot
put
/ball

rol in

o
e
spee

ut
r
ings

tion
n
eratu

t
eratu

tion
ectio
l inp
larm

Analo trol inpu

cont
bear

direc
limit

rotec
temp

ntro

prot
emp
Go-a
CSA

tion
igna
ns

eve

with

rsible
g co

fog p
con
ensio

= 54
idity
nal t
c sle

i-op
/ No

rnal
, UL,

ds

Alarm

PWM

IP 68

Reve
Page
Hum
Spee

Mult
Sinte

Inter
Exte

IP >
Dim

Salt
Go-
VDE Please note that these special versions are not possible for
Axial fans
all voltages and speeds, and not in all combinations.
mm Series OPTIONAL P.
c
The special versions are designed for specific customers
119 x 38 4400 ja • • • • • • • – • • – – – 58/59
c
and projects. As a rule they are not available off the shelf
119 x 38 4100 N ja / • • • • • • • – • • • • – 60
c
and are tied to minimum volumes.
119 x 38 4100 NH..NH6 ja • • • • • • • – • • • • – 61
c 119 x 38 4100 NH7..NH8 ja • • • • • • • – • – – • – 62
c 119 x 38 DV 4100 ja • • • • • • • – • • • • – 63
Please consult your customer support representative
c 127 x 38 5200 N ja • • • • • • • – • • • • – 64
about the feasibility of your special variant.
c 127 x 38 DV 5200 ja • • • • • • • – • • – • – 65
c 135 x 38 5100 N ja • • • • • • • – • • – • – 66
c 140 x 51 5300 ja • • • • • • • – • • – • – 67
c 140 x 51 5300 TD ja • • • • • • • • • • – • – 68
Ø 150 x 38 7100 N ja • • • • • • • – • • • • – 69
Ø 150 x 55 7200 N ja • • • • • • • – • • • • – 70
172 x 150 x 51 6400 ja • • • • • • • – • • – • – 71
172 x 150 x 51 6400 TD ja • • • • • • • – • • – • • 72
172 x 150 x 51 DV 6400 ja • • • • • • • – • • – • – 73
172 x 150 x 51 DV 6400 TD ja • • • • • • • – • • – • • 74
172 x 160 x 51 6300 TD ja • • • • • • • • • • – • – 75
Ø 172 x 51 6300 N ja • • • • • • • • • • • • – 76
Ø 172 x 51 6300 NTD ja • • • • • • • • • • – • – 77
Ø 172 x 51 6300 ja • • • • • • • – • • – • – 78
Ø 172 x 51 6300 TD ja • • • • • • • • • • – • – 79
Ø 172 x 51 DV 6300 TD ja • • • • • • • • • • – • – 80
Ø 200 x 51 2200 FTD ja • • • • • • • • • • – • – 81
c 225 x 80 K1G 200 ja • • • • – • • • • – – • – 82
c 225 x 89 K3G 200 ja • • • • – • • • • – – • – 84
Subject to alterations

– not yet available Sleeve bearings


• available Ball bearings
2016-01

30
Information
max. 4,6 m /h 3
DC axial fans
 25 x 8 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Humidity protection
on rotor
– Connection: Via single wires AWG 28,
TR 64
– Mass: 5g

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (20 °C)

Service life L10 (60 °C)


Series 250

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

255 M 2,3 1,2 5 4,5...5,5 5 <3 0,2 6 500 -10...+70 45 000 / 17 500 47 500 ➀
255 N 3,5 1,9 5 4,5...5,5 16 <3 0,4 9 600 -10...+70 40 000 / 15 000 42 500 ➁
255 H 4,6 2,6 5 4,5...5,5 23 4,4 0,6 12 000 -10...+55 35 000 / 15 000* 37 500 ➂
252 N 3,4 1,9 12 10...14 15 <3 0,5 9 000 -10...+70 40 000 / 15 000 42 500 ➁

ACmaxx / EC fans
252 H 4,6 2,6 12 10...14 23 4,4 0,7 12 000 -10...+55 35 000 / 15 000* 37 500 ➂
Subject to alterations

* at 55 °C

AC axial fans
AC centrifugal fans
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis. tin-p
lated
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
31
max. 9 m /h 3
DC axial fans
 40 x 10 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Humidity protection
– Connection: Via single wires AWG 28,
TR 64
– Highlights: Some models are suitable
for use at high ambient
temperatures
– Mass: 17 g

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (20 °C)

Service life L10 (60 °C)


Series 400 F

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

405 F 8 4,7 5 4,5...5,5 22,1 4,4 0,7 5 400 -20...+70 45 000 / 17 500 47 500 ➁
405 FH 9 5,3 5 4,5...5,5 26,0 4,6 0,9 6 000 -20...+70 45 000 / 17 500 47 500 ➂
412 FM 6 3,5 12 10...14 17,0 3,8 0,5 4 300 -20...+70 45 000 / 17 500 47 500 ➀
412 F 8 4,7 12 10...14 22,1 4,4 0,7 5 400 -20...+70 45 000 / 17 500 47 500 ➁
412 FH 9 5,3 12 10...14 26,0 4,6 0,8 6 000 -20...+70 45 000 / 17 500 47 500 ➂
414 F 8 4,7 24 20...28 22,1 4,4 0,8 5 400 -20...+70 45 000 / 17 500 47 500 ➁
414 FH 9 5,3 24 21,6...26,4 26,0 4,4 0,9 6 000 -20...+70 45 000 / 17 500 47 500 ➂

Model with temperature range up to +85 °C.


412 FM-074 6 3,5 12 10...14 17,0 3,8 0,4 4 300 -20...+85 45 000 / 17 500 47 500 ➀
412 F-130 8 4,7 12 10...14 22,1 4,4 0,6 5 400 -20...+85 45 000 / 17 500 47 500 ➁
412 FH-132 9 5,3 12 10...14 26,0 4,6 0,8 6 000 -20...+85 45 000 / 17 500 47 500 ➂
Subject to alterations

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement tin-p
lated
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

32 from p. 242
Information
max. 13,5 m /h 3
DC axial fans
 40 x 20 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - PWM control input
– Connection: Via single wires AWG 28, - Humidity protection
TR 64
– Highlights: Some models are suitable
for use at high ambient
temperatures
– Mass: 27 g

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (20 °C)

Service life L10 (60 °C)


Series 400

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

405 10,0 5,9 5 4,5...5,5 18 3,8 0,9 6 000 -20...+70 50 000 / 20 000 52 500 ➀
412 10,0 5,9 12 10...14 18 3,8 0,8 6 000 -20...+70 50 000 / 20 000 52 500 ➀
412 H 13,5 7,9 12 10...14 29 4,7 1,6 8 100 -20...+60 45 000 / 17 500 47 500 ➁

ACmaxx / EC fans
414 10,0 5,9 24 20...28 18 3,8 1,0 6 000 -20...+70 50 000 / 20 000 52 500
414 H 13,5 7,9 24 20...26,5 29 4,7 1,7 8 100 -20...+60 45 000 / 17 500 47 500 ➁

Model with temperature range up to +85 °C.

412-099 10,0 5,9 12 10...14 18 3,8 0,8 6 000 -20...+85 50 000 / 20 000 52 500 ➀
Subject to alterations

AC axial fans
AC centrifugal fans
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement tin-p
lated
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
33
max. 38 m /h 3
DC axial fans
 40 x 28 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - External temperature sensor
– Connection: Via single wires AWG 28, - PWM control input
UL 1061 - Humidity protection
– Mass: 45 g - Salt fog protection

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 420 J

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

422 JM 24 14,2 12 8...13,8 42 5,5 2,4 11 400 -20...+70 75 000 / 37 500 127 500 ➀
422 JN 31 18,3 12 8...13,8 48 6,0 4,1 14 250 -20...+70 67 500 / 35 000 115 000 ➁
422 JH 38 22,4 12 8...13,8 54 6,6 6,9 17 250 -20...+70 60 000 / 30 000 102 500 ➂
424 JM 24 14,2 24 16...28 42 5,5 2,7 11 400 -20...+70 75 000 / 37 500 127 500 ➀
424 JN 31 18,3 24 16...28 48 6,0 4,3 14 250 -20...+70 67 500 / 35 000 115 000 ➁
424 JH 38 22,4 24 16...26,4 54 6,6 6,9 17 250 -20...+65 60 000 / 32 500 102 500 ➂
Subject to alterations

tin-plate
d

Air performance measured as per: ISO 5801, Ø 42,5 ± 0,3


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

34 from p. 242
Information
max. 20 m /h 3
DC axial fans
 50 x 15 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - PWM control input
– Connection: Via single wires AWG 28, - Humidity protection
TR 64
– Highlights: Some models are suitable
for use at high ambient
temperatures
– Mass: 27 g

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (20 °C)

Service life L10 (60 °C)


Series 500 F

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

512 F 20 11,8 12 10,8...13,2 30 4,5 0,8 5 000 -20...+70 50 000 / 20 000 52 500 ➁
514 F 20 11,8 24 21,6...26,4 30 4,5 0,9 5 000 -20...+70 50 000 / 20 000 52 500 ➁

Model with temperature range up to +85 °C.

ACmaxx / EC fans
512 FL-547 11 6,5 12 10,2...13,8 18 3,7 0,4 3 000 -20...+85 50 000 / 20 000 52 500 ➀
512 F-532 20 11,8 12 10,8...13,2 30 4,5 0,9 5 000 -20...+85 50 000 / 20 000 52 500 ➁
Subject to alterations

AC axial fans
AC centrifugal fans

tin-p
lated
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
35
max. 33 m /h 3
DC axial fans
 60 x 15 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - PWM control input
– Connection: Via single wires AWG 28, - Humidity protection
TR 64
– Highlights: Some models are suitable
for use at high ambient
temperatures
– Mass: 30 g

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (20 °C)

Service life L10 (60 °C)


Series 600 F

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

605 F 29 17,1 5 4,5...5,2 27 4,4 1,1 4 000 -20...+50 50 000 / 20 000 52 500 ➁
612 FL 19 11,2 12 11,5...13,2 16 3,6 0,4 2 650 -20...+70 50 000 / 20 000 52 500 ➀
612 F 29 17,1 12 10,8...13,2 27 4,4 1,0 3 900 -20...+70 50 000 / 20 000 52 500 ➁
612 FH 33 19,4 12 10,0...13,2 31 4,8 1,5 4 500 -20...+60 45 000 / 17 500 47 500 ➂
614 F 29 17,1 24 21,6...26,4 27 4,4 1,1 3 900 -20...+70 50 000 / 20 000 52 500 ➁
614 F/39 H-691 33 19,4 24 16...28 31 4,8 1,4 4 500 -20...+60 45 000 / 17 500 47 500 ➂

Model with temperature range up to +80 / 85 °C.

612 FL-680 19 11,2 12 11,5...14 16 3,6 0,5 2 650 -20...+85 50 000 / 20 000 52 500 ➀
612 F-637 29 17,1 12 10,8...12,6 27 4,4 1,0 3 900 -20...+80 50 000 / 20 000 52 500 ➁
Subject to alterations

tin-p
lated

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

36 from p. 242
Information
max. 67 m /h 3
DC axial fans
 60 x 25 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Alarm with limit speed
TR 64 - External temperature sensor
– Highlights: Very low-noise motor - Internal temperature sensor
– Mass: 85 g - PWM control input
- Analog control input
- Humidity protection

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 620

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

622 L 21 12,4 12 8...15 20 3,7 0,5 3 200 -20...+85 80 000 / 20 000 135 000 ➀
622 M 30 17,7 12 8...15 29 4,3 1,0 4 550 -20...+75 77 500 / 30 000 130 000 ➁
622 N 40 23,5 12 8...15 35 4,7 1,9 6 100 -20...+70 72 500 / 35 000 122 500 ➂
622 H 46 27,1 12 8...15 39 5,1 2,3 6 850 -20...+70 70 000 / 35 000 117 500 ➃

ACmaxx / EC fans
622 HH 56 33,0 12 8...15 43 5,6 3,5 8 200 -20...+70 65 000 / 32 500 110 000 ➄
622/2 H3P 67 39,4 12 8...13,2 48 5,9 5,5 9 700 -20...+60 52 500 / 32 500 87 500 ➅
624 L 21 12,4 24 18...28 20 3,7 1,0 3 200 -20...+70 80 000 / 40 000 135 000 ➀
624 M 30 17,7 24 12...28 29 4,3 1,5 4 550 -20...+70 77 500 / 37 500 130 000 ➁
624 N 40 23,5 24 12...28 35 4,7 2,2 6 100 -20...+70 72 500 / 35 000 122 500 ➂
624 H 46 27,1 24 18...28 39 5,1 2,4 6 850 -20...+70 70 000 / 35 000 117 500 ➃
624 HH 56 33,0 24 18...28 43 5,6 3,6 8 200 -20...+70 65 000 / 32 500 110 000 ➄

AC axial fans
624/2 H3P 67 39,4 24 18...28 48 5,9 5,6 9 700 -20...+60 52 500 / 32 500 87 500 ➅
628 HH 56 33,0 48 36...60 43 5,6 4,2 8 200 -20...+70 65 000 / 32 500 110 000 ➄
Subject to alterations

AC centrifugal fans

tin-p
lated
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
37
max. 44 m /h 3
DC axial fans
 60 x 25 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Alarm with limit speed
TR 64 - External temperature sensor
– Highlights: Developed for applications with - PWM control input
demanding environmental - Analog control input
requirements - Humidity protection
– Mass: 70 g - Salt fog protection
- Degree of protection: IP 54 / IP 68

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 630

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

632 NU 40 23,5 12 6...15 33 5,2 1,8 5 900 -20...+70 85 000 / 42 500 142 500 ➀
632/2 HPU 44 25,9 12 10,8...13,2 35 5,4 1,5 6 300 -20...+70 85 000 / 42 500 142 500 ➁
634 NU 40 23,5 24 12...30 34 5,1 1,6 5 900 -20...+70 85 000 / 42 500 142 500 ➀
634 HHU 58 34,1 24 18...28 44 6,1 3,2 8 500 -20...+70 75 000 / 37 500 127 500 ➂
634/2 HHPU 58 34,1 24 18...28 44 6,1 3,2 8 500 -20...+70 75 000 / 37 500 127 500 ➂
638/2 HPU 44 25,9 48 40...60 35 5,4 1,8 6 300 -20...+70 85 000 / 42 500 142 500 ➁
Subject to alterations

tin-pla
ted

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

38 from p. 242
Information
max. 56 m /h 3
DC axial fans
 60 x 25 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Humidity protection
TR 64 - Degree of protection: IP 54 / IP 68
– Highlights: Some models are suitable
for use at high ambient
temperatures until 85 °C
– Mass: 66 g

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 600 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

612 NGLE 21 12,4 12 8...15 16 3,6 0,6 2 500 -20...+85 80 000 / 27 500 135 000 ➀
612 NLE 21 12,4 12 8...15 16 3,6 0,4 2 500 -20...+85 80 000 / 27 500 135 000 ➀
612 NGMLE 25 14,7 12 8...15 19 3,9 0,7 3 000 -20...+80 80 000 / 32 500 135 000 ➁
612 NMLE 25 14,7 12 8...15 19 3,9 0,4 3 000 -20...+85 80 000 / 27 500 135 000 ➁

ACmaxx / EC fans
612 NGME 35 20,6 12 8...15 28 4,6 1,2 4 100 -20...+75 80 000 / 35 000 135 000 ➂
612 NME 35 20,6 12 8...15 28 4,6 0,8 4 100 -20...+75 80 000 / 35 000 135 000 ➂
612 NN 42 24,7 12 8...15 35 5,0 1,5 5 100 -20...+70 70 000 / 35 000 117 500 ➃
612 NH 43 25,3 12 8...15 37 5,3 1,8 5 600 -20...+70 70 000 / 35 000 117 500 ➄
612 NHH-118 56 33,0 12 8...15 41 5,7 2,9 6 800 -20...+70 60 000 / 30 000 102 500 ➅
614 NGL 21 12,4 24 18...28 16 3,6 1,0 2 500 -20...+70 80 000 / 40 000 135 000 ➀
614 NL 21 12,4 24 18...28 16 3,6 0,8 2 500 -20...+70 80 000 / 40 000 135 000 ➀
614 NGML 25 14,7 24 18...28 19 3,9 1,2 3 000 -20...+70 80 000 / 40 000 135 000 ➁

AC axial fans
614 NML 25 14,7 24 18...28 19 3,9 1,0 3 000 -20...+70 80 000 / 40 000 135 000 ➁
614 NGM 35 20,6 24 18...28 28 4,6 1,7 4 100 -20...+70 80 000 / 40 000 135 000 ➂
614 NM 35 20,6 24 18...28 28 4,6 1,3 4 100 -20...+70 80 000 / 40 000 135 000 ➂
614 NN 42 24,7 24 18...28 35 5,0 1,8 5 100 -20...+70 70 000 / 35 000 117 500 ➃
614 NH 43 25,3 24 18...26 37 5,3 2,1 5 600 -20...+70 70 000 / 35 000 117 500 ➄
614 NHH 56 33,0 24 18...26 41 5,7 2,9 6 850 -20...+70 60 000 / 30 000 102 500 ➅
614 NHH-119 56 33,0 24 18...28 41 5,7 2,9 6 850 -20...+70 60 000 / 30 000 102 500 ➅ AC centrifugal fans

618 NM 35 20,6 48 36...56 28 4,6 1,9 4 100 -20...+70 80 000 / 40 000 135 000 ➂
618 NN 42 24,7 48 36...56 35 5,0 2,1 5 100 -20...+65 70 000 / 40 000 117 500 ➃

tin-pla
ted
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
39
max. 41 m /h 3
DC axial fans
 60 x 25 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Automatic speed adjustment - Humidity protection
with temperature sensor
– Mass: 66 g

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 600 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

VARIOFAN

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

30°C 18 10,6 14 3,5 1,3 2 150 ➀


612 NGMI 12 8...12,6 -20...+65 80 000 / 45 000 135 000
55°C 35 20,6 28 4,6 1,7 4 100 ➁
30°C 16 9,4 16 3,6 1,0 2 400 ➂
612 NMI 12 8...12,6 -20...+65 80 000 / 45 000 135 000
55°C 35 20,6 28 4,6 1,4 4 100 ➃
30°C 23 13,5 18 3,8 1,7 2 900 ➄
612 NGNI 12 8...12,6 -20...+65 70 000 / 40 000 117 500
55°C 41 24,1 35 5,0 2,4 5 100 ➅
30°C 23 13,5 18 3,8 1,2 2 900 ➄
612 NNI 12 8...12,6 -20...+65 70 000 / 40 000 117 500
55°C 41 24,1 35 5,0 1,5 5 100 ➅
30°C 23 13,5 18 3,8 1,7 2 900 ➄
612 NGNV 12 8...12,6 -20...+65 70 000 / 40 000 117 500
55°C 41 24,1 35 5,0 2,4 5 100 ➅
Subject to alterations

Air performance measured as per:


ISO 5801, Installation category A,
without accidental contact.
Noise: Total sound power level LWA
ISO 103002 measured on half-sphere
of 2 m; Sound pressure level LpA
measured at 1 m distance to fan axis.
The acoustic values are only valid for
the described measurement set-up
and may vary depending on the
installation situation. In case of any
deviation to the standard setup, the
values have to be checked and
reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general
conditions

V-Types I-Types

tin-pla
ted

The temperature sensor for con-


trolling the motor speed is not in- Temperature sensor (NTC-resistor)
cluded in delivery. for controlling the motor speed is
Temperature sensor LZ 370 see positioned directly in the air flow.
accessories.

Guard grilles
2016-01

40 from p. 242
Information
max. 82 m /h 3
DC axial fans
 60 x 32 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 24, - Alarm with limit speed
TR 64 - External temperature sensor
– Mass: 100 g - PWM control input
- Analog control input
- Humidity protection

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 600 J

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

612 JH 70 41,1 12 7...13,6 53 6,4 7,7 11 700 -20...+70 57 500 / 27 500 97 500 ➀
614 JH 70 41,1 24 14...26,4 53 6,4 7,7 11 700 -20...+70 57 500 / 27 500 97 500 ➀
618 JH 70 41,1 48 36...56 53 6,4 7,7 11 700 -20...+70 57 500 / 27 500 97 500 ➀

ACmaxx / EC fans
Fan types with streamer and integrated guard grille.
614 J/2 HHP 82 48,3 24 18...30 62 7,6 14,6 15 000 -20...+75 65 000 / 25 000 110 000 ➁
618 J/2 HHP 82 48,3 48 38...58 62 7,6 14,6 15 000 -20...+75 65 000 / 25 000 110 000 ➁
Subject to alterations

Rear view of types 614 J/2HHP and 618 J/2HHP

AC axial fans
AC centrifugal fans

tin-pla
ted
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
41
max. 44 m /h 3
DC axial fans
 70 x 15 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Humidity protection
– Connection: Via single wires AWG 24 to
AWG 28, TR 64
– Mass: 53 g

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 700 F

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

712 F/2L-005* 28 16,5 12 8...13,8 25 4,7 0,6 3 300 -20...+70 60 000 / 30 000 102 500 ➀
712 F/2M-006* 36 21,2 12 8...13,8 32 5,0 1,1 4 300 -20...+70 60 000 / 30 000 102 500 ➁
712 F 44 25,9 12 8...13,8 38 5,3 1,7 5 300 -20...+70 60 000 / 30 000 102 500 ➂
714 F 44 25,9 24 18...28 38 5,3 1,5 5 300 -20...+70 60 000 / 30 000 102 500 ➂
Subject to alterations

*Version with 3-pin Molex plug housing 22-01-2035


Molex Contacts 08-50-0113

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement tin-pla
ted
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

42 from p. 242
Information
max. 117 m /h 3
DC axial fans
 80 x 25 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 24, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Very low-noise motor - PWM control input
– Mass: 105 g - Analog control input
- Humidity protection

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 8450

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

8452 GL 32 18,8 12 8...15 14 3,3 0,4 1 700 -20...75 80 000 / 35 000 135 000 ➀
8452 GM 58 34,1 12 8...15 32 4,7 1,3 3 100 -20...75 80 000 / 35 000 135 000 ➁
8452 GN 68 40,0 12 8...15 36 5,0 1,8 3 600 -20...70 70 000 / 35 000 117 500 ➂

ACmaxx / EC fans
Models with 25 kHz PWM control and speed signal to 4-wire specification (see page 179).
8452/2 GHP 75 44,1 12 10,8...13,2 38 5,3 2,5 4 000 -20...70 70 000 / 35 000 117 500 ➃
8452/2 GHHP 83 48,8 12 10,8...13,2 42 5,5 3,5 4 400 -20...60 65 000 / 40 000 110 000 ➄

Models with 1-30 kHz PWM control and speed signal.


8452/2 H4P 117 68,8 12 8...15 50 6,4 6,8 6 200 -20...70 60 000 / 30 000 102 500 ➅
8454/2 H4P 117 68,8 24 20,0...26,4 50 6,4 6,8 6 200 -20...70 60 000 / 30 000 102 500 ➅
Subject to alterations

AC axial fans
AC centrifugal fans

tin-pla
ted
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
43
max. 79 m /h 3
DC axial fans
 80 x 25 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 24, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Some models are suitable - PWM control input
for use at high ambient - Analog control input
temperatures until 85 °C - Humidity protection
– Mass: 95 g - Degree of protection: IP 54 / IP 68

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 8400 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

8412 NGLE 33 19,4 12 8...15 12 3,5 0,5 1 500 -20...+85 80 000 / 27 500 135 000 ➀
8412 NLE 33 19,4 12 8...15 17 3,7 0,3 1 500 -20...+85 80 000 / 27 500 135 000 ➀
8412 NGMLE 45 26,5 12 8...15 19 3,9 0,9 2 050 -20...+80 80 000 / 32 500 135 000 ➁
8412 NMLE 45 26,5 12 8...15 21 4,0 0,6 2 050 -20...+85 80 000 / 27 500 135 000 ➁
8412 NGME 58 34,1 12 8...15 26 4,3 1,4 2 600 -20...+75 80 000 / 35 000 135 000 ➂
8412 NME 58 34,1 12 8...15 27 4,4 1,0 2 600 -20...+75 80 000 / 35 000 135 000 ➂
8412 NG 69 40,6 12 8...15 32 4,7 2,0 3 100 -20...+70 70 000 / 35 000 117 500 ➃
8412 N 69 40,6 12 8...15 32 4,7 1,7 3 100 -20...+70 70 000 / 35 000 117 500 ➃
8412 NH 79 46,5 12 8...13,2 37 5,0 2,1 3 600 -20...+70 70 000 / 35 000 117 500 ➄
8412 NH-217 79 46,5 12 8...15 37 5,0 2,5 3 600 -20...+70 70 000 / 35 000 117 500 ➄
8414 NGL 33 19,4 24 18...28 12 3,5 0,9 1 500 -20...+70 80 000 / 40 000 135 000 ➀
8414 NL 33 19,4 24 18...28 17 3,7 0,8 1 500 -20...+70 80 000 / 40 000 135 000 ➀
8414 NGML 45 26,5 24 18...28 19 3,9 1,2 2 050 -20...+70 80 000 / 40 000 135 000 ➁
8414 NML 45 26,5 24 18...28 21 4,0 1,1 2 050 -20...+70 80 000 / 40 000 135 000 ➁
8414 NGM 58 34,1 24 18...28 26 4,3 1,4 2 600 -20...+70 80 000 / 40 000 135 000 ➂
8414 NM 58 34,1 24 18...28 27 4,4 1,4 2 600 -20...+70 80 000 / 40 000 135 000 ➂
8414 NG 69 40,6 24 18...28 32 4,7 2,2 3 100 -20...+70 70 000 / 35 000 117 500 ➃
8414 N 69 40,6 24 18...28 32 4,7 1,8 3 100 -20...+70 70 000 / 35 000 117 500 ➃
8414 NH 79 46,5 24 18...26 37 5,0 2,4 3 600 -20...+70 70 000 / 35 000 117 500 ➄
8414 NH-221 79 46,5 24 18...28 37 5,0 2,2 3 600 -20...+70 70 000 / 35 000 117 500 ➄
8418 N 69 40,6 48 36...56 32 4,7 2,0 3 100 -20...+70 70 000 / 35 000 117 500 ➃

tin-pla
ted

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

44 from p. 242
Information
max. 58 m /h 3
DC axial fans
 80 x 25 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - External temperature sensor
– Connection: Via single wires AWG 24, - Internal temperature sensor
TR 64 - Humidity protection
– Highlights: Automatic speed adjustment
with temperature sensor
– Mass: 95 g

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 8400 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

VARIOFAN

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

30°C 20 11,8 < 10 <3 0,9 900 ➀


8412 NGLV 12 10...14 -20...+65 80 000 / 45 000 135 000
50°C 33 19,4 12 3,5 1,1 1 500 ➁
30°C 27 15,9 < 10 3,0 1,1 1 200 ➂
8412 NGMLV 12 8...14 -20...+65 80 000 / 45 000 135 000
50°C 45 26,6 19 3,9 1,5 2 050 ➃

ACmaxx / EC fans
30°C 35 20,6 < 13 3,5 1,4 1 600 ➄
8412 NGMI 12 8...14 -20...+65 80 000 / 45 000 135 000
50°C 58 34,1 26 4,3 2,0 2 600 ➅
Subject to alterations

Air performance measured as per: ISO 5801, Installation category A, without accidental contact.
AC axial fans
AC centrifugal fans
Noise: Total sound power level LWA ISO 103002 measured on half-sphere of 2 m; Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement set-up and may vary depending on the installation situation. In case of any deviation to the standard setup,
the values have to be checked and reviewed once installed or fitted. For detailed information see http://www.ebmpapst.com/general conditions

V-Types I-Types
tin-pla
ted
Accessories

The temperature sensor for con-


trolling the motor speed is not in- Temperature sensor (NTC-resistor)
cluded in delivery. for controlling the motor speed is
Temperature sensor LZ 370 see positioned directly in the air flow.
Representatives

accessories.

Guard grilles
2016-01

from p. 242
45
max. 80 m /h 3
DC axial fans
 80 x 32 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Alarm with limit speed
TR 64 - External temperature sensor
– Mass: 170 g - Internal temperature sensor
- PWM control input
- Analog control input
- Humidity protection
- Protection against fog
- Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 8300

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

8312 L 32 18,8 12 6...15 24 4,0 1,2 2 000 -20...+75 80 000 / 32 500 135 000 ➀
8312 M 48 28,3 12 6...15 34 5,0 2,2 3 000 -20...+75 70 000 / 27 500 117 500 ➁
8312 54 31,8 12 6...15 36 5,2 2,6 3 300 -20...+75 70 000 / 27 500 117 500 ➂
8312 HL 67 39,4 12 6...15 43 5,8 4,0 4 200 -20...+75 62 500 / 25 000 105 000 ➃
8312 H 80 47,1 12 6...12,6 48 6,2 6,4 5 000 -20...+60 55 000 / 35 000 92 500 ➄
8314 L 32 18,8 24 12...31,5 24 4,0 1,0 2 000 -20...+75 80 000 / 32 500 135 000 ➀
8314 M 48 28,3 24 12...31,5 34 5,0 2,3 3 000 -20...+75 70 000 / 27 500 117 500 ➁
8314 54 31,8 24 12...31,5 36 5,2 2,7 3 300 -20...+75 70 000 / 27 500 117 500 ➂
8314 HL 67 39,4 24 12...31,5 43 5,8 4,3 4 200 -20...+75 62 500 / 25 000 105 000 ➃
8314 H 80 47,1 24 12...28 48 6,2 6,0 5 000 -20...+75 55 000 / 20 000 92 500 ➄
8318 54 31,8 48 36...60 36 5,2 3,0 3 300 -20...+75 70 000 / 27 500 117 500 ➂
8318 HL 67 39,4 48 36...60 43 5,8 4,2 4 200 -20...+75 62 500 / 25 000 105 000 ➃
8318 H 80 47,1 48 36...60 48 6,2 6,2 5 000 -20...+65 55 000 / 30 000 92 500 ➄
Subject to alterations

Rotor protrusion max. 0,4 mm.

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
tin-pla
values have to be checked and reviewed once installed or ted
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

46 from p. 242
Information
max. 222 m /h 3
DC axial fans
 80 x 38 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 24 - External temperature sensor
(H3 and H4: AWG 22), TR 64 - Internal temperature sensor
– Mass: 160 g (H3 and H4: 200 g) - PWM control input
- Analog control input
- Humidity protection
- Degree of protection: IP 54 / IP 68

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 8200 J

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

8212 JN 132 78 12 7...13,8 55 6,6 10 8 400 -20...+70 62 500 / 32 500 105 000 ➀
8212 JH3 190 112 12 6...13,8 66 7,3 26* 12 000 -20...+70 55 000 / 27 500 92 500 ➁
8212 JH4 222 131 12 6...13,8 71 7,8 39* 14 000 -20...+70 50 000 / 25 000 85 000 ➂
8214 JN 132 78 24 18...26,4 55 6,6 11 8 400 -20...+70 62 500 / 32 500 105 000 ➀

ACmaxx / EC fans
8214 JH3 190 112 24 12...27,6 66 7,3 26* 12 000 -20...+70 55 000 / 27 500 92 500 ➁
8214 JH4 222 131 24 12...27,6 71 7,8 38* 14 000 -20...+70 50 000 / 25 000 85 000 ➂
8218 JN 132 78 48 36...53 55 6,6 11 8 400 -20...+70 62 500 / 32 500 105 000 ➀
8218 JH3 190 112 48 36...53 66 7,3 25* 12 000 -20...+70 55 000 / 27 500 92 500 ➁
8218 JH4 222 131 48 20...58 71 7,8 36* 14 000 -20...+70 50 000 / 25 000 85 000 ➂
Subject to alterations

8200 JH3 and JH4 also available as standard with PWM control input and speed signal.
Speed control range from 2000 rpm up to maximum speed. Stationary at 0 % PWM, maximum speed at interruption of control wire.

AC axial fans
* Input power at free air flow, these values can be significantly higher in the operating point.

AC centrifugal fans
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis. tin-pla
The acoustic values are only valid for the described measurement
ted
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
47
max. 102 m /h 3
DC axial fans
 92 x 25 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 24, - External temperature sensor
TR 64 - Internal temperature sensor
– Mass: 100 g - PWM control input
- Analog control input
- Humidity protection
- Degree of protection: IP 54 / IP 68

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 3400 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

3412 NGLE 61 35,9 12 8...15 23 4,0 1,1 1 950 -20...+80 80 000 / 22 500 135 000 ➀
3412 NLE 61 35,9 12 8...15 23 4,0 0,8 1 950 -20...+85 80 000 / 17 500 135 000 ➀
3412 NGME 72 42,4 12 8...15 28 4,3 1,6 2 300 -20...+75 75 000 / 27 500 127 500 ➁
3412 NME 72 42,4 12 8...15 28 4,3 1,1 2 300 -20...+75 75 000 / 27 500 127 500 ➁
3412 NG 84 49,4 12 8...15 32 4,7 1,9 2 700 -20...+70 70 000 / 35 000 117 500 ➂
3412 N 84 49,4 12 8...15 32 4,7 1,7 2 700 -20...+70 70 000 / 35 000 117 500 ➂
3412 NGH 94 55,3 12 8...15 36 5,0 2,3 3 000 -20...+70 70 000 / 35 000 117 500 ➃
3412 NH 94 55,3 12 8...15 36 5,0 2,1 3 000 -20...+70 70 000 / 35 000 117 500 ➃
3412 NGHH 102 60,0 12 8...13,2 39 5,1 3,2 3 250 -20...+60 70 000 / 45 000 117 500 ➄
3412 NHH 102 60,0 12 8...13,2 39 5,1 2,9 3 250 -20...+60 70 000 / 45 000 117 500 ➄
3412 NHH-379 102 60,0 12 8...15 39 5,1 2,7 3 250 -20...+70 70 000 / 35 000 117 500 ➄
3414 NGL 61 35,9 24 18...28 23 4,0 1,4 1 950 -20...+70 80 000 / 40 000 135 000 ➀
3414 NL 61 35,9 24 18...28 23 4,0 1,1 1 950 -20...+70 80 000 / 40 000 135 000 ➀
3414 NGM 72 42,4 24 18...28 28 4,3 1,7 2 300 -20...+70 75 000 / 37 500 127 500 ➁
3414 NM 72 42,4 24 18...28 28 4,3 1,4 2 300 -20...+70 75 000 / 37 500 127 500 ➁
3414 NG 84 49,4 24 18...28 32 4,7 2,5 2 700 -20...+70 70 000 / 35 000 117 500 ➂
3414 N 84 49,4 24 18...28 32 4,7 2,1 2 700 -20...+70 70 000 / 35 000 117 500 ➂
3414 NGH 94 55,3 24 18...26 36 5,0 3,0 3 000 -20...+70 70 000 / 35 000 117 500 ➃
3414 NH 94 55,3 24 18...26 36 5,0 2,3 3 000 -20...+70 70 000 / 35 000 117 500 ➃
3414 NGHH 102 60,0 24 18...26 39 5,1 3,2 3 250 -20...+70 70 000 / 35 000 117 500 ➄
3414 NGHH-389 102 60,0 24 18...28 39 5,1 3,2 3 250 -20...+70 70 000 / 35 000 117 500 ➄
3414 NHH 102 60,0 24 18...26 39 5,1 3,1 3 250 -20...+70 70 000 / 35 000 117 500 ➄
3414 NHH-386 102 60,0 24 18...28 39 5,1 3,2 3 250 -20...+70 70 000 / 35 000 117 500 ➄
3418 N 84 49,4 48 36...56 32 4,7 2,4 2 700 -20...+70 70 000 / 35 000 117 500 ➂
Other 48 VDC models on request.

tin-pla
ted

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

48 from p. 242
Information
max. 84 m /h 3
DC axial fans
 92 x 25 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - External temperature sensor
– Connection: Via single wires AWG 24, - Internal temperature sensor
TR 64 - Humidity protection
– Highlights: Automatic speed adjustment
with temperature sensor
– Mass: 100 g

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 3400 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

VARIOFAN

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

30°C 44 25,9 14 3,5 1,5 1 400 ➀


3412 NGMV 12 8...14 -20...+65 75 000 / 42 500 127 500
50°C 72 42,4 28 4,3 2,0 2 300 ➁
30°C 50 29,4 16 3,7 1,6 1 600 ➂
3412 NGV 12 8...12,6 -20...+65 75 000 / 42 500 127 500
50°C 84 49,4 32 4,7 2,5 2 700 ➃

ACmaxx / EC fans
Subject to alterations

AC axial fans
The temperature sensor for con-
trolling the motor speed is not in-
cluded in delivery.
Temperature sensor LZ 370 see
accessories.

AC centrifugal fans

tin-pla
ted
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
49
max. 133 m /h 3
DC axial fans
 92 x 32 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 24 - External temperature sensor
UL 1061, TR 64 - Internal temperature sensor
– Mass: 190 g - PWM control input
- Analog control input
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54 / IP 68

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 3300 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

3312 NL 56 33 12 6...15 24 4,1 0,8 1 850 -20...+75 80 000 / 35 000 135 000 ➀
3312 NM 68 40 12 6...15 29 4,5 1,3 2 250 -20...+75 70 000 / 30 000 117 500 ➁
3312 NN 80 47 12 6...15 35 4,7 1,8 2 650 -20...+75 70 000 / 30 000 117 500 ➂
3312 NH 93 54 12 6...15 38 5,1 2,8 3 050 -20...+75 65 000 / 27 500 110 000 ➃
3312 NHH 107 63 12 6...15 42 5,4 3,4 3 450 -20...+75 57 500 / 25 000 97 500 ➄
3312 NH3 133 78 12 6...14 50 6,0 6,7 4 350 -20...+70 50 000 / 25 000 85 000 ➅
3314 NN 80 47 24 18...28 35 4,7 1,8 2 650 -20...+75 70 000 / 30 000 117 500 ➂
3314 NH 93 54 24 18...28 38 5,1 2,6 3 050 -20...+75 65 000 / 27 500 110 000 ➃
3314 NHH 107 63 24 18...28 42 5,4 3,5 3 450 -20...+75 57 500 / 25 000 97 500 ➄
3314 NH3 133 78 24 18...28 50 6,0 6,7 4 350 -20...+75 50 000 / 22 500 85 000 ➅
3318 NN 80 47 48 36...60 35 4,7 1,8 2 650 -20...+75 70 000 / 30 000 117 500 ➂
3318 NH 93 54 48 36...60 38 5,1 3,5 3 050 -20...+75 65 000 / 27 500 110 000 ➃
3318 NH3 133 78 48 36...58 50 6,0 6,5 4 350 -20...+75 50 000 / 22 500 85 000 ➅
Subject to alterations

tin-plated

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002 Ø 100,1 ± 0,3
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

50 from p. 242
Information
max. 280 m /h 3
DC axial fans
 92 x 38 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 24 - Alarm with limit speed
(H3 and H4: AWG 22), TR 64 - External temperature sensor
– Mass: 240 g (H3 and H4: 280 g) - Internal temperature sensor
- PWM control input
- Analog control input
- Humidity protection
- Degree of protection: IP 54 / IP 68

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 3200 J

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

3212 JN 130 76,5 12 7...13,8 51 6,1 7,5 6 000 -20 ...+70 70 000 / 35 000 117 500 ➀
3212 JH 146 86,0 12 7...15 55 6,4 9,0 6 800 -20 ...+70 70 000 / 35 000 117 500 ➁
3212 JH3 237 139,5 12 6...13,8 69 7,8 31,0* 11 000 -20 ...+70 65 000 / 32 500 110 000 ➂
3212 JH4 280 164,8 12 6...13,8 73 8,2 50,0* 13 000 -20 ...+70 60 000 / 30 000 110 000 ➃

ACmaxx / EC fans
3214 JN 130 76,5 24 11...28 51 6,1 6,5 6 000 -20 ...+70 70 000 / 35 000 117 500 ➀
3214 JH 146 86,0 24 12...30 55 6,4 9,0 6 800 -20 ...+70 70 000 / 35 000 117 500 ➁
3214 JH3 237 139,5 24 12...27,6 69 7,8 30,0* 11 000 -20 ...+70 65 000 / 32 500 110 000 ➂
3214 JH4 280 164,8 24 12...27,6 73 8,2 50,0* 13 000 -20 ...+70 60 000 / 30 000 110 000 ➃
3218 JN 130 76,5 48 36...56 51 6,1 7,0 6 000 -20 ...+70 70 000 / 35 000 117 500 ➀
3218 JH 146 86,0 48 36...53 55 6,4 9,5 6 800 -20 ...+70 70 000 / 35 000 117 500 ➁
3218 JH3 237 139,5 48 20...58,0 69 7,8 29,0* 11 000 -20 ...+70 65 000 / 32 500 110 000 ➂

AC axial fans
3218 JH4 280 164,8 48 20...58,0 73 8,2 50,0* 13 000 -20 ...+70 60 000 / 30 000 110 000 ➃
Subject to alterations
3200 JH3 and JH4 also available as standard with PWM control input and speed signal.
Speed control range from 2000 rpm up to maximum speed. Standstill at 0 % PWM, maximum speed if control wire is interrupted.
* Input power at free air flow, these values can be significantly higher in the operating point.

AC centrifugal fans

tin-pla
ted
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
51
max. 270 m /h 3
DC axial fans
 92 x 38 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Mass: 240 g - PWM control input
- Analog control input
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54 / IP 68

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 3250 J

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

3252 J/2 H3P 270 158 12 7...13,2 64 7,6 35,0 7 450 -20...+70 85 000 / 42 500 142 500 ➂
3254 J/2 H3P 270 158 24 14...26,4 64 7,6 35,0 7 450 -20...+70 85 000 / 42 500 142 500 ➂
3258 J/2 HP** 145 85 48 36...56,0 46 5,8 7,0 4 100 -20...+70 100 000 / 50 000 170 000 ➀
3258 J/2 HHP 235 138 48 36...56,0 59 7,0 24,3 6 650 -20...+70 90 000 / 45 000 152 500 ➁
3258 J/2 H3P 270 158 48 36...56,0 64 7,6 33,6 7 450 -20...+70 85 000 / 42 500 142 500 ➂
Subject to alterations
* Input power at free air flow, these values can be significantly higher in the operating point.
** On request

2
tin-pla
ted

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
1 measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
cfm
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

52 from p. 242
Information
max. 170 m /h 3
DC axial fans
 119 x 25 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 24, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Ball bearings and sleeve - PWM control input
bearings available - Analog control input
– Mass: 175 g - Humidity protection

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 4400 F

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

4412 FGL 94 55 12 7...14 26 3,9 1,3 1 600 -20...+75 80 000 / 32 500 135 000 ➀
4412 FGML 114 67 12 7...12,6 32 4,3 2,0 1 950 -20...+75 75 000 / 30 000 127 500 ➁
4412 FML 114 67 12 7...12,6 32 4,3 2,0 1 950 -20...+75 75 000 / 30 000 127 500 ➁
4412 FGM 140 82 12 7...12,6 38 4,8 3,2 2 400 -20...+75 70 000 / 27 500 117 500 ➂

ACmaxx / EC fans
4412 FM 140 82 12 7...12,6 38 4,8 3,2 2 400 -20...+75 70 000 / 27 500 117 500 ➂
4412 FG 170 100 12 8...12,6 43 5,3 5,3 2 900 -20...+60 60 000 / 37 500 102 500 ➃
4412 F 170 100 12 8...12,6 43 5,3 5,3 2 900 -20...+60 60 000 / 37 500 102 500 ➃
4414 FL 94 55 24 18...28 26 3,9 1,2 1 600 -20...+75 80 000 / 32 500 135 000 ➀
4414 FM 140 82 24 12...28 38 4,8 3,1 2 400 -20...+75 70 000 / 27 500 117 500 ➂
4414 FG 170 100 24 12...28 43 5,3 5,0 2 900 -20...+60 60 000 / 37 500 102 500 ➃
4414 F 170 100 24 12...28 43 5,3 5,0 2 900 -20...+60 60 000 / 37 500 102 500 ➃

AC axial fans
4418 FG 170 100 48 28...53 43 5,3 5,4 2 900 -20...+60 60 000 / 37 500 102 500 ➃
4418 F 170 100 48 28...53 43 5,3 5,4 2 900 -20...+60 60 000 / 37 500 102 500 ➃
Subject to alterations

Available on request:
Fan housing with moulded-in
spacers. For mounting over AC centrifugal fans
both flanges.
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis. tin-pla
The acoustic values are only valid for the described measurement ted
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
53
max. 170 m /h 3
DC axial fans
Ø 127 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 24, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Ball bearings and sleeve - PWM control input
bearings available - Analog control input
optional: - Rotation reversal - Humidity protection
- Symmetrical - Reversible direction of rotation
impeller - Symmetrical impeller
– Mass: 170 g
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 4400 F

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

NEW 4412 FGL-573 91 54 12 7...15 26 3,9 1,2 1 600 -20...+75 80 000 / 32 500 135 000 ➀
NEW 4412 FGML-XXX* 114 67 12 7...12,6 32 4,3 2,0 1 950 -20...+75 75 000 / 30 000 127 500 ➁
NEW 4412 FGM-XXX* 140 82 12 7...12,6 38 4,8 3,2 2 400 -20...+75 75 000 / 27 500 117 500 ➂
NEW 4412 FG-XXX* 170 100 12 8...12,6 43 5,3 5,3 2 900 -20...+60 60 000 / 37 500 102 500 ➃
Subject to alterations

* On request Other voltage versions (24VDC, 48VDC), speed variations and ball bearing designs are available as additional versions.

n Ped LwA n Ped LwA


rpm W dB(A) rpm W dB(A)

  1 515 1 44   2 225 4 51
  1 516 1 38   2 235 4 50
  1 547 1 40   2 304 4 51
  1 567 1 39   2 369 4 52

  1 856 2 50   2 670 6 59
  1 848 2 44   2 685 6 59
  1 882 2 44   2 783 6 56
  1 929 2 46   2 869 6 57

200 4
0,2

150 ±0
,5
27
3 Ø1
0,15

100 Air performance measured as per: ISO 5801,


2
Installation category A, without accidental contact.
0,1

Noise: Total sound power level LWA ISO 103002


1 measured on half-sphere of 2 m;
50
0,05

Sound pressure level LpA measured at 1 m distance to fan axis.


The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
0 20 40 60 80 cfm to be checked and reviewed once installed or fitted.
For detailed information see
20 40 60 80 100 120 140 http://www.ebmpapst.com/general conditions tin-plated

Guard grilles
2016-01

54 from p. 242
Information
max. 225 m /h 3
DC axial fans
 119 x 25 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Mass: 240 g - PWM control input
- Analog control input
- Humidity protection

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 4400 FN

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

4412 FNH 225 132 12 9...13,2 55 6,7 12 5 400 -20...+70 60 000 / 30 000 102 500 ➁
4414 FNN 200 118 24 14...28 52 6,5 8,3 4 850 -20...+70 60 000 / 30 000 102 500 ➀
4414 FNH 225 132 24 18...26,4 55 6,7 12 5 400 -20...+70 60 000 / 30 000 102 500 ➁

ACmaxx / EC fans
4418 FNH 225 132 48 36...53 55 6,7 12 5 400 -20...+70 60 000 / 30 000 102 500
Subject to alterations

AC axial fans
AC centrifugal fans

tin-pla
ted
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
55
max. 204 m /h 3
DC axial fans
 119 x 32 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Alarm with limit speed
TR 64 - External temperature sensor
– Highlights: Ball bearings and sleeve - Internal temperature sensor
bearings available - PWM control input
– Mass: 220 g - Analog control input
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 4300

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

4312 GL 95 56 12 6...15 30 4,3 1,2 1 550 -20...+75 80 000 / 35 000 135 000 ➀
4312 L 95 56 12 6...15 30 4,3 1,2 1 550 -20...+75 80 000 / 35 000 135 000 ➀
4312 GM 140 82 12 6...15 39 5,3 3,1 2 300 -20...+75 70 000 / 30 000 117 500 ➁
4312 M 140 82 12 6...15 39 5,3 3,1 2 300 -20...+75 70 000 / 30 000 117 500 ➁
4312 G 170 100 12 6...15 45 5,8 5,0 2 800 -20...+70 62 500 / 30 000 105 000 ➂
4312 170 100 12 6...15 45 5,8 5,0 2 800 -20...+70 62 500 / 30 000 105 000 ➂
4312-179 204 120 12 6...13,2 51 6,4 9,4 3 400 -20...+65 47 500 / 27 500 80 000 ➄
4314 L 95 56 24 12...28 30 4,3 1,2 1 550 -20...+75 80 000 / 35 000 135 000 ➀
4314 M 140 82 24 12...28 39 5,3 2,8 2 300 -20...+75 70 000 / 30 000 117 500 ➁
4314 G 170 100 24 12...28 45 5,8 4,7 2 800 -20...+75 62 500 / 27 500 105 000 ➂
4314 170 100 24 12...28 45 5,8 5,0 2 800 -20...+75 62 500 / 27 500 105 000 ➂
4314-147 180 106 24 12...28 47 6,1 4,7 3 000 -20...+75 57 500 / 25 000 80 000 ➃
4314-180 204 120 24 12...26 51 6,4 8,5 3 400 -20...+70 45 000 / 22 500 75 000 ➄
4318 M 140 82 48 36...56 39 5,3 3,6 2 300 -20...+75 70 000 / 30 000 117 500 ➁
4318 170 100 48 36...53 45 5,8 5,1 2 800 -20...+75 62 500 / 27 500 105 000 ➂
Subject to alterations

Rotor protrusion max. 0.4 mm.

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have tin-pla
ted
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

56 from p. 242
Information
max. 170 m /h 3
DC axial fans
 119 x 32 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Alarm with limit speed
TR 64 - External temperature sensor
– Highlights: Speed automatically adjusted - Internal temperature sensor
to cooling requirement - PWM control input
– Mass: 220 g - Analog control input
- Humidity protection

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 4300

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

VARIOFAN

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

25°C 65 38 25 3,9 1,1 1 100 ➀


4312 MT 12 8...15 -20...+65 70 000 / 40 000 117 500
50°C 138 81 39 5,3 3,3 2 300 ➁
25°C 85 50 29 4,2 1,7 1 400 ➂
4312 T 12 8...13,2 -20...+65 65 000 / 35 000 110 000
50°C 170 100 45 5,8 5,0 2 800 ➃

ACmaxx / EC fans
30°C 85 50 29 4,2 1,6 1 400 ➂
4314 T 24 18...32 -20...+65 65 000 / 35 000 110 000
50°C 170 100 45 5,8 4,8 2 800 ➃
Subject to alterations

AC axial fans
The temperature sensor for controlling the
motor speed is not included in delivery.
Temperature sensor LZ 370 see accessories.

AC centrifugal fans

Rotor protrusion max. 0.4 mm.


Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have tin-pla
ted
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
57
max. 205 m /h 3
DC axial fans
 119 x 38 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 24, - Alarm with limit speed
TR 64 - External temperature sensor
– Mass: 270 g - Internal temperature sensor
- PWM control input
- Analog control input
- Humidity protection
- Degree of protection: IP 54

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 4400

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

4412 L 150 88 12 7...14 37 5,0 2,2 2 700 -20...+80 67 500 / 22 500 115 000 ➂
4412 ML 168 99 12 7...15 40 5,1 3,0 3 000 -20...+80 67 500 / 22 500 115 000 ➃
4412 M 184 108 12 7...14 42 5,3 3,8 3 300 -20...+75 65 000 / 25 000 110 000 ➄
4412 N 205 121 12 7...14 46 5,6 5,3 3 650 -20...+70 62 500 / 30 000 105 000 ➅
4414 L3 100 59 24 12...28 26 4,0 1,0 1 800 -20...+80 75 500 / 22 500 127 500 ➀
4414 LL 124 73 24 12...28 33 4,5 1,6 2 250 -20...+80 70 000 / 22 500 117 500 ➁
4414 L 150 88 24 18...28 37 5,0 2,4 2 700 -20...+80 67 500 / 22 500 115 000 ➂
4414 ML 168 99 24 12...28 40 5,1 3,2 3 000 -20...+80 67 500 / 22 500 115 000 ➃
4414 M 184 108 24 18...28 42 5,3 4,1 3 300 -20...+75 65 000 / 25 000 110 000 ➄
4414 N 205 121 24 18...28 46 5,6 5,4 3 650 -20...+70 62 500 / 30 000 105 000 ➅
4418 L 150 88 48 36...60 37 5,0 2,5 2 700 -20...+75 67 500 / 27 500 115 000 ➂
4418 ML 168 99 48 36...60 40 5,1 3,2 3 000 -20...+75 67 500 / 27 500 115 000 ➃
4418 M 184 108 48 36...60 42 5,3 4,2 3 300 -20...+70 65 000 / 32 500 110 000 ➄
4418 N 205 121 48 36...60 46 5,6 5,4 3 650 -20...+70 62 500 / 30 000 105 000 ➅
Subject to alterations

Further variants can be found on page 59.

tin-pla
ted

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

58 from p. 242
Information
max. 285 m /h 3
DC axial fans
 119 x 38 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 24, - Alarm with limit speed
TR 64 - External temperature sensor
– Mass: 270 g - Internal temperature sensor
- PWM control input
- Analog control input
- Humidity protection
- Degree of protection: IP 54

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 4400

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

4412 H 240 141 12 7...14 50 6,0 8,6 4 300 -20...+70 57 500 / 27 500 97 500 ➀
4412/2 HHP 285 168 12 7...14,5 55 6,4 13,0 5 000 -20...+70 50 000 / 25 000 85 000 ➁
4414 H 240 141 24 18...28 50 6,0 8,6 4 300 -20...+70 57 500 / 27 500 97 500 ➀
4414 HH 285 165 24 16...28 55 6,4 14,0 5 000 -20...+70 50 000 / 25 000 85 000 ➁

ACmaxx / EC fans
4414/2 HHP 285 168 24 18...28 55 6,4 12,0 5 000 -20...+70 50 000 / 25 000 85 000 ➁
4418 H 240 141 48 36...60 50 6,0 8,6 4 300 -20...+70 57 500 / 27 500 97 500 ➀
4418/2 HHP 285 168 48 36...60 55 6,4 13,0 5 000 -20...+70 50 000 / 25 000 85 000 ➁
Subject to alterations

AC axial fans
AC centrifugal fans

tin-pla
ted
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
59
max. 237 m /h 3
DC axial fans
 119 x 38 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Intake over struts - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: On flat connectors, 2.8 x 0.5 mm - Alarm with limit speed
Also available with wires as - External temperature sensor
an option - Internal temperature sensor
– Highlights: Housing with grounding lug for - PWM control input
screw M4 x 8 (Torx) - Analog control input
– Mass: 390 g - Humidity protection
- Salt fog protection
- Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 4100 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

4182 NGX 160 94 12 6...15 44 5,3 3,7 2 800 -20...+75 85 000 / 37 500 142 500 ➀
4182 NX 180 106 12 6...15 49 5,7 4,9 3 200 -30...+75 85 000 / 37 500 142 500 ➁
4182 NXH 237 140 12 7...14 57 6,5 11,0 4 400 -30...+55 70 000 / 50 000 117 500 ➂
4184 NGX 160 94 24 12...31,5 44 5,3 3,3 2 800 -20...+75 85 000 / 37 500 142 500 ➀
4184 NXM 160 94 24 12...31,5 44 5,3 3,2 2 800 -30...+75 85 000 / 37 500 142 500 ➀
4184 NX 180 106 24 12...31,5 49 5,7 4,9 3 200 -30...+70 85 000 / 42 500 142 500 ➁
4184 NXH 237 140 24 12...28 57 6,5 11,0 4 400 -30...+70 70 000 / 35 000 117 500 ➂
4188 NGX 160 94 48 36...60 44 5,3 3,6 2 800 -20...+75 85 000 / 37 500 142 500 ➀
4188 NXM 160 94 48 36...60 44 5,3 3,5 2 800 -30...+75 85 000 / 37 500 142 500 ➀
Subject to alterations

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles Connection cables


2016-01

60 from p. 242 from p. 255


Information
max. 440 m /h 3
DC axial fans
 119 x 38 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Intake over struts - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22 UL - Alarm with limit speed
1007, TR 64 - External temperature sensor
– Highlights: Housing with grounding lug for - Internal temperature sensor
screw M4 x 8 (Torx) - PWM control input
– Mass: 390 g - Analog control input
- Humidity protection
- Salt fog protection

DC centrifugal fans
- Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 4100 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

High Performance

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

4112 NHH 260 153 12 9...15 60 6,8 13,3 5 000 -20...+65 70 000 / 55 000 117 500 ➀
4112 NH3 310 182 12 9...15 65 7,2 21,6 6 000 -20...+65 65 000 / 37 500 110 000 ➁
4112 NH4 355 209 12 9...14 67 7,4 32,0 6 800 -20...+65 62 500 / 35 000 105 000 ➂
4114 NHH 260 153 24 16...30 60 6,8 12,4 5 000 -20...+65 70 000 / 52 500 117 500 ➀

ACmaxx / EC fans
4114 NH3 310 182 24 16...30 65 7,2 19,5 6 000 -20...+65 65 000 / 37 500 110 000 ➁
4114 NH4 355 209 24 16...30 67 7,4 30,0 6 800 -20...+65 62 500 / 35 000 105 000 ➂
4114 NH5 390 230 24 16...30 70 7,6 45,0* 7 500 -20...+65 62 500 / 35 000 105 000 ➃
4114 NH6 440 259 24 16...30 73 8,1 65,0* 8 400 -20...+65 60 000 / 32 500 102 500 ➄
4118 NHH 260 153 48 36...60 60 6,8 12,0 5 000 -20...+65 70 000 / 52 500 117 500 ➀
4118 NH3 310 182 48 36...60 65 7,2 20,0 6 000 -20...+65 65 000 / 37 500 110 000 ➁
4118 NH4 355 209 48 36...60 67 7,4 28,0 6 800 -20...+65 62 500 / 35 000 105 000 ➂

AC axial fans
4118 NH5 390 230 48 36...60 70 7,6 45,0* 7 500 -20...+65 62 500 / 35 000 105 000 ➃
4118 NH6 440 259 48 36...60 73 8,1 62,0* 8 400 -20...+65 60 000 / 32 500 102 500 ➄
Subject to alterations
* Input power at free air flow, these values can be significantly higher in the operating point.

* Input power - in operation


Fan type optimum
operating range (W) AC centrifugal fans
4114 NH5 55
4114 NH6 95
4118 NH5 55
4118 NH6 95

tin-pla
ted
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
61
max. 570 m /h 3
DC axial fans
 119 x 38 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Intake over struts - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 18, 20 or - Alarm with limit speed
AWG 22, TR 64, speed signal - External temperature sensor
and control input AWG 22 - Internal temperature sensor
– Highlights: Highly efficient and smoothly - PWM control input
running 3-phase fan drive - Analog control input
Housing with grounding lug for - Humidity protection
screw M4 x 8 (Torx) - Salt fog protection
– Mass: 425 g
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 4100 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

High Performance

Nominal speed
Input power**
Voltage range

Ball bearings
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

4114 N/2 H7P 500 294 24 16...30 76 8,5 90 9 500 -20...+75 57 500 / 25 000 97 500 ➀
4114 N/2 H8P 570 336 24 16...30 78 8,9 120 11 000 -20...+75 55 000 / 22 500 92 500 ➁
4118 N/2 H7P 500 294 48 36...60* 76 8,5 90 9 500 -20...+75 57 500 / 25 000 97 500 ➀
4118 N/2 H8P 570 336 48 36...60* 78 8,9 120 11 000 -20...+75 55 000 / 22 500 92 500 ➁
Subject to alterations
* 36...72 VDC on request.

Speed control range from 500 rpm up to maximum speed. Standstill at 0 % PWM, maximum speed if control wire is interrupted.
To attain the specified service life, an external capacitor must be wired between the plus and minus strands.
Please note the wiring suggestion on page 16.
** Input power at free air flow, these values can be significantly higher in the operating point.

** Input power - in operation


Fan type optimum
operating range (W)
4114 NH7P 100
4114 NH8P 160
4118 NH7P 100
4118 NH8P 160

tin-pla
ted

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

62 from p. 242
Information
max. 280 m /h 3
DC axial fans
 119 x 38 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Available in Die-cast aluminium (See chapter DC fans - specials)
Impeller: GRP1) (PA) - Speed signal

DC axial fans
– Direction of air flow: Exhaust over struts - Go- / NoGo-alarm
– Direction of rotation: Counter-clockwise, seen - Alarm with limit speed
on rotor - External temperature sensor
– Connection: Via single wires AWG 22, - Internal temperature sensor
TR 64 - PWM control input
– Highlights: Housing with grounding lug for - Analog control input
screw M4 x 8 (Torx) - Humidity protection
– Mass: 375 g - Salt fog protection

DC centrifugal fans
(with metal housing: 455 g) - Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series DV 4100

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

DV 4112 N 280 165 12 9...15 61 6,9 21,0 6 000 -20...+65 70 000 / 40 000 117 500 ➀
DV 4114 N 280 165 24 16...30 61 6,9 20,5 6 000 -20...+65 70 000 / 40 000 117 500 ➀
DV 4118 N 280 165 48 36...60 61 6,9 20,0 6 000 -20...+65 70 000 / 40 000 117 500 ➀

ACmaxx / EC fans
Subject to alterations
* Input power at free air flow, these values can be significantly higher in the operating point.

AC axial fans
AC centrifugal fans
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis. tin-pla
The acoustic values are only valid for the described measurement ted
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
63
max. 340 m /h 3
DC axial fans
 127 x 38 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Mass: 310 g - PWM control input
- Analog control input
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 5200 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Input power**
Voltage range

Ball bearings
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

5212 NM 187 110 12 7...14,5 43 5,3 4,1 2 750 -20...+75 62 500 / 27 500 105 000 ➀
5212 NN 216 127 12 7...14 46 5,6 6,2 3 150 -20...+70 57 500 / 25 000 97 500 ➁
5212 NH 252 148 12 7...14 51 6,0 9,8 3 650 -20...+70 45 000 / 22 500 75 000 ➂
5212 NHH* 340 200 12 9...15 58 6,6 19,0 4 900 -20...+65 45 000 / 25 000 75 000 ➃
5214 NM 187 110 24 12...28 43 5,3 4,6 2 750 -20...+75 62 500 / 27 500 105 000 ➀
5214 NN 216 127 24 12...28 46 5,6 6,0 3 150 -20...+75 57 500 / 25 000 97 500 ➁
5214 NH 252 148 24 12...28 51 6,0 9,8 3 650 -20...+70 45 000 / 22 500 75 000 ➂
5214 NHH* 340 200 24 16...30 58 6,6 17,5 4 900 -20...+65 45 000 / 25 000 75 000 ➃
5218 NM 187 110 48 36...56 43 5,3 4,5 2 750 -20...+75 62 500 / 27 500 105 000 ➀
5218 NN 216 127 48 36...56 46 5,6 6,2 3 150 -20...+70 57 500 / 32 500 97 500 ➁
5218 NH 252 148 48 36...56 51 6,0 9,6 3 650 -20...+55 45 000 / 32 500 75 000 ➂
5218 NHH* 340 200 48 36...60 58 6,6 18,0 4 900 -20...+65 45 000 / 25 000 75 000 ➃
Subject to alterations
** Input power at free air flow, these values can be significantly higher in the operating point.

*Models NHH: Fan housing


with moulded-in spacers.

tin-pla
ted

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

64 from p. 242
Information
max. 320 m /h 3
DC axial fans
 127 x 38 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Available in Die-cast aluminium (See chapter DC fans - specials)
Metal flange - Speed signal

DC axial fans
Impeller: GRP1) (PA) - Go- / NoGo-alarm
– Direction of air flow: Exhaust over struts - Alarm with limit speed
– Direction of rotation: Counter-clockwise, seen - External temperature sensor
on rotor - Internal temperature sensor
– Connection: Via single wires AWG 22, - PWM control input
TR 64 - Analog control input
– Highlights: Housing with grounding lug for - Humidity protection
screw M4 x 8 (Torx) - Salt fog protection

DC centrifugal fans
– Mass: 415 g (with metal housing: 490 g) - Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series DV 5200

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

DV 5212 N 270 159 12 9...15 56 6,4 21,0 5 000 -20...+65 70 000 / 40 000 117 500 ➀
DV 5214 N 270 159 24 16...30 56 6,4 20,4 5 000 -20...+65 70 000 / 40 000 117 500 ➀
DV 5218 N 270 159 48 36...60 56 6,4 18,5 5 000 -20...+65 70 000 / 40 000 117500 ➀

ACmaxx / EC fans
Model comes standard with speed signal and PWM control input. Other versions by request.

DV 5214/2 HP 320 188 24 16...30 62 7,2 38,5 6 000 -20...+65 62 500 / 35 000 105 000 ➁
Subject to alterations
Speed control range from 1000 rpm up to maximum speed. Standstill at 0 % PWM,
maximum speed if control wire is interrupted.
* Input power at free air flow, these values can be significantly higher in the operating point.

AC axial fans
AC centrifugal fans

tin-pla
ted
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
65
max. 260 m /h 3
DC axial fans
 135 x 38 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: Painted sheet steel (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Housing with grounding lug for - PWM control input
screw M4 x 8 (Torx) - Analog control input
48 V version incl. screws - Humidity protection
– Mass: 650 g - Salt fog protection
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 5100 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

5112 N 260 153 12 6...15 48 6,1 9,5 2 900 -25...+72 80 000 / 37 500 135 000 ➀
5114 N 260 153 24 12...30 48 6,1 9,5 2 900 -25...+72 80 000 / 37 500 135 000 ➀
5118 N 260 153 48 24...60 48 6,1 9,5 2 900 -25...+72 80 000 / 37 500 135 000 ➀
Subject to alterations
* Input power at free air flow, these values can be significantly higher in the operating point.

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
tin-pla
The acoustic values are only valid for the described measurement ted
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

66 from p. 242
Information
max. 340 m /h 3
DC axial fans
 140 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Intake over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Housing with grounding lug for - PWM control input
screw M4 x 8 (Torx) - Analog control input
– Mass: 900 g - Humidity protection
- Salt fog protection

DC centrifugal fans
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 5300

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

5314/2 HP 340 200 24 16...28 64 7,2 28,4 5 000 -20...+65 77 500 / 40 000 130 000 ➀
5318/2 HP 340 200 48 36...72 64 7,2 27 5 000 -20...+65 77 500 / 40 000 130 000 ➀
Subject to alterations
Speed control range from 700 rpm up to maximum speed. Standstill at 0 % PWM,
maximum speed if control wire is interrupted.

ACmaxx / EC fans
* Input power at free air flow, these values can be significantly higher in the operating point.

AC axial fans
AC centrifugal fans

tin-pla
ted
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
67
max. 670 m /h 3
DC axial fans
 140 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Intake over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 20 and - External temperature sensor
AWG 22, TR 64 - Internal temperature sensor
– Highlights: Highly efficient and smoothly - PWM control input
running 3-phase fan drive - Analog control input
– Mass: 900 g - Multi-option control input
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 5300 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

5312/2 TDHP 410 241 12 8...16 70 7,7 43 6 000 -20...+70 70 000 / 35 000 117 500 ➀
5314/2 TDHP 410 241 24 16...36 70 7,7 42 6 000 -20...+70 70 000 / 35 000 117 500 ➀
5314/2 TDHHP 490 288 24 16...36 75 8,1 67 7 000 -20...+70 62 500 / 30 000 105 000 ➁
5318/2 TDHP 410 241 48 36...72 70 7,7 42 6 000 -20...+70 70 000 / 35 000 117 500 ➀
5318/2 TDHHP 490 288 48 36...72 75 8,1 66 7 000 -20...+70 62 500 / 30 000 105 000 ➁
5318/2 TDH4P 670 394 48 36...72 79 8,8 149 9 200 -20...+65 57 500 / 32 500 97 500 ➂
Subject to alterations
Speed control range from 1000 rpm up to maximum speed. Standstill at 0 % PWM,
maximum speed if control wire is interrupted.
* Input power at free air flow, these values can be significantly higher in the operating point.

tin-pla
ted

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

68 from p. 242
Information
max. 360 m /h 3
DC axial fans
Ø 150 x 38 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: Painted sheet steel (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Housing with grounding lug for - PWM control input
screw M4 x 8 (Torx) - Analog control input
– Mass: 620 g - Humidity protection
- Salt fog protection

DC centrifugal fans
- Degree of protection: IP 54 / IP 68

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 7100 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

7112 N 308 181 12 6...15 53 6,2 12,0 2 850 -25...+72 80 000 / 37 500 135 000 ➀
7114 N 308 181 24 12...30 53 6,2 12,0 2 850 -25...+72 80 000 / 37 500 135 000 ➀
7114 NH 360 212 24 12...26,5 58 6,7 19,0 3 350 -25...+72 75 000 / 35 000 127 500 ➁

ACmaxx / EC fans
7118 N 308 181 48 24...60 53 6,2 12,0 2 850 -25...+72 80 000 / 37 500 135 000
Subject to alterations
* Input power at free air flow, these values can be significantly higher in the operating point.

AC axial fans
AC centrifugal fans

Strand fastened using cable tie;


cable tie protrudes 1 mm.
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact. tin-pla
ted
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
69
max. 360 m /h 3
DC axial fans
Ø 150 x 55 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Housing with grounding lug for - PWM control input
screw M4 x 8 (Torx) - Analog control input
– Mass: 725 g - Humidity protection
- Salt fog protection
- Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 7200 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

7212 N 360 212 12 6...15 53 6,2 12,0 3 050 -25...+72 80 000 / 37 500 135 000 ➀
7214 N 360 212 24 12...30 53 6,2 12,0 3 050 -25...+72 80 000 / 37 500 135 000 ➀
7218 N 360 212 48 24...60 53 6,2 12,0 3 050 -25...+72 80 000 / 37 500 135 000 ➀
Subject to alterations
* Input power at free air flow, these values can be significantly higher in the operating point.

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see tin-pla
ted
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

70 from p. 242
Information
max. 480 m /h 3
DC axial fans
172 x 150 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: On flat plugs 3 x 0.5 mm - External temperature sensor
– Highlights: Housing with grounding lug for - Internal temperature sensor
screw M4 x 8 (Torx) - PWM control input
– Mass: 760 g - Analog control input
- Humidity protection
- Salt fog protection

DC centrifugal fans
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 6400

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Input power***
Voltage range

Ball bearings
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

6412 M 350 206 12 8...15 52 6,0 12 2 850 -20...+72 80 000 / 37 500 135 000 ➀
6424 M 350 206 24 12...32 52 6,0 12 2 850 -20...+72 80 000 / 37 500 135 000 ➀
6424 410 241 24 12...28 57 6,4 17 3 400 -20...+72 75 000 / 35 000 127 500 ➁
6424 H 480 283 24 12...28 63 7,1 26 4 000 -20...+55** 70 000 / 50 000 117 500 ➂

ACmaxx / EC fans
6448 410 241 48 28...60 57 6,4 17 3 400 -20...+72 75 000 / 35 000 127 500 ➁
6448 H* 480 283 48 28...60 63 7,1 26 4 000 -20...+55** 70 000 / 50 000 117 500 ➂
Subject to alterations
* Strand 310 mm.
** 72 °C versions on request
*** Input power at free air flow, these values can be significantly higher in the operating point.

AC axial fans
AC centrifugal fans
Accessories

7,5 d
eep
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
Representatives

fitted. For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles Connection cables


2016-01

from p. 242 from p. 255


71
max. 900 m /h 3
DC axial fans
172 x 150 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 18, 20 - External temperature sensor
or AWG 22, TR 64, speed signal - Internal temperature sensor
and control input AWG 22 - PWM control input
– Highlights: Highly efficient and smoothly - Analog control input
running 3-phase fan drive - Humidity protection
Housing with grounding lug - Salt fog protection
for screw M4 x 8 (Torx) - Degree of protection: IP 54
– Mass: 760 g - Reversible direction of rotation
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 6400 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Input power**
Voltage range

Ball bearings
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

min 90 53 18 — 2 800 ➀
6424 TD... 24 16...28 -20...+60 70 000 / 45 000 117 500
max 600 353 65 7,4 50 5 100 ➁
min 90 53 18 — 2 800 ➀
6448 TD... 48 40...55* -20...+60 70 000 / 45 000 117 500
max 600 353 65 7,4 50 5 100 ➁
min 90 53 18 — 2 800 ➀
6448 TDHH... 48 36...72 -20...+60 70 000 / 45 000 117 500
max 900 530 78 8,6 163 7 500 ➂
Subject to alterations
* Variants with an extended voltage range available to deliver on request.

Models 6424 TD..., 6448 TD... and 6448 TDHH... are available in customer-specific, custom-developed variants only.
The data specified here is technically feasible benchmark values. The fans can be specially adapted to your application with signal
outputs and control inputs.
For details of the technical possibilities, refer to the chapters on the sensor signal, alarm signal and control inputs beginning on page 165.
** Input power at free air flow, these values can be significantly higher in the operating point.

tin-plate
d

(7,5 de
ep)

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

72 from p. 242
Information
max. 530 m /h 3
DC diagonal fans
172 x 160 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Housing with grounding lug for - PWM control input
screw M4 x 8 (Torx) - Analog control input
– Mass: 820 g - Humidity protection
- Salt fog protection

DC centrifugal fans
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series DV 6400

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

DV 6424 530 312 24 16...28 65 7,3 40 4 300 -20...+75 90 000 / 35 000 152 500 ➀
DV 6448 530 312 48 28...60 65 7,3 40 4 300 -20...+75 90 000 / 35 000 152 500 ➀
Subject to alterations

ACmaxx / EC fans
AC axial fans
AC centrifugal fans

tin-pla
ted
Accessories

(7,5
deep
)
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
Representatives

fitted. For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
73
max. 680 m /h 3
DC diagonal fans
172 x 160 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Highly efficient and smoothly - PWM control input
running 3-phase fan drive - Analog control input
Housing with grounding lug - Humidity protection
for screw M4 x 8 (Torx) - Salt fog protection
– Mass: 820 g - Degree of protection: IP 54
- Reversible direction of rotation
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series DV 6400 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

DV 6424 TD 680 400 24 16...28 71 7,9 91 5 500 -20...+60 65 000 / 40 000 110 000 ➁
min 100 59 29 — 2 800 ➀
DV 6424 TD... 24 16...28 -20...+60 65 000 / 40 000 110 000
max 680 400 71 7,9 91 5 500 ➁
min 100 59 29 — 2 800 ➀
DV 6448 TD... 48 40...55 -20...+60 65 000 / 40 000 110 000
max 680 400 71 7,9 86 5 500 ➁
Subject to alterations
Models DV 6424 TD... and DV 6448 TD... are available in customer-specific, custom-developed variants only.
The data specified here is technically feasible benchmark values. The fans can be specially adapted to your application with signal
outputs and control inputs.
For details of the technical possibilities, refer to the chapters on the sensor signal, alarm signal and control inputs beginning on page 165.
* Input power at free air flow, these values can be significantly higher in the operating point.

tin-pla
ted

(7,5 d
eep)
Air performance measured as per: ISO 5801,
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

74 from p. 242
Information
max. 930 m /h 3
DC axial fans
172 x 160 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 18, 20 - External temperature sensor
or AWG 22, TR 64, speed signal - Internal temperature sensor
and control input AWG 22 - PWM control input
– Highlights: Highly efficient and smoothly - Analog control input
running 3-phase fan drive - Multi-option control input
Housing with grounding lug - Humidity protection

DC centrifugal fans
for screw M4 x 8 (Torx) - Salt fog protection
– Mass: 910 g - Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 6300 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

6314/2 TDHHP-015 710 418 24 16...36 69 7,9 67 7 000 -20...+75 62 500 / 25 000 105 000 ➀
6318/2 TDH4P-007 930 546 48 36...72 75 8,4 150 9 200 -20...+75 52 500 / 20 000 87 500 ➁
Subject to alterations
Speed control range from 1000 rpm up to maximum speed. Standstill at 0 % PWM,
maximum speed if control wire is interrupted.

ACmaxx / EC fans
* Input power at free air flow, these values can be significantly higher in the operating point.

AC axial fans
AC centrifugal fans

tin-pla
ted
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure- 7,6 d
eep
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
Representatives

fitted. For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
75
max. 685 m /h 3
DC axial fans
Ø 172 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP 1) (PA) (See chapter DC-fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: (+) and GND AWG 20, UL 1007, - External temperature sensor
TR 64, speed signal and control - Internal temperature sensor
input AWG 22, UL 1007, TR 64 - PWM control input (Standard)
– Highlights: Highly efficient and smoothly - Analog control input
running 3-phase fan drive - Multi-option control input
Housing with grounding lug - Humidity protection
for screw M4 x 8 (Torx) - Salt fog protection
– Mass: 850 g - Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 6300 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

6314 N/2 HHP 540 318 24 16…36 - 6,9 30 4 000 -20…+70 80 000 / 40 000 135 000 ➀
6318 N/2 H3P 685 403 48 36…72 - 7,5 53 5 000 -20…+70 77 500 / 40 000 130 000 ➁
Subject to alterations
Speed control range from 1000 rpm up to maximum speed. Standstill at 0 % PWM, maximum speed if control wire is interrupted.
* Input power at free air flow, these values can be significantly higher in the operating point.

tin-plated

Ø 162+0,15
-0,3

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact. Ø 166
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to
fan axis. The acoustic values are only valid for the described
measurement set-up and may vary depending on the
installation situation. In case of any deviation to the
standard setup, the values have to be checked and
reviewed once installed or fitted. For detailed information
see http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

76 from p. 242
max. 1 030 m /h 3
DC axial fans
Ø 172 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP 1) (PA) (See chapter DC-fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: AWG 18, 20 UL 1007, - External temperature sensor
TR 64, speed signal and control - Internal temperature sensor
input AWG 22, UL 1007, TR 64 - PWM control input (Standard)
– Highlights: Highly efficient and smoothly - Analog control input
running 3-phase fan drive - Multi-option control input
Housing with grounding lug - Humidity protection
for screw M4 x 8 (Torx) - Salt fog protection
– Mass: 850 g - Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 6300 NTD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

6314 N/2 TDHHP 970 571 24 16…36 - 8,3 135 7 200 -20…+70 62.500 / 32.500 105.000 ➀
6318 N/2 TDH3P 1 030 606 48 36…72 83 8,4 152 7 500 -20…+70 60.000 / 30.000 102.500 ➁
Subject to alterations
Speed control range from 1000 rpm up to maximum speed. Standstill at 0 % PWM, maximum speed if control wire is interrupted.
* Input power at free air flow, these values can be significantly higher in the operating point.

Ø 162+0,15
-0,3

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact. Ø 166
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to
fan axis. The acoustic values are only valid for the described
measurement set-up and may vary depending on the
installation situation. In case of any deviation to the
standard setup, the values have to be checked and
reviewed once installed or fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
77
max. 545 m /h 3
DC axial fans
Ø 172 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Housing with grounding lug for - PWM control input
screw M4 x 8 (Torx) - Analog control input
– Mass: 910 g - Humidity protection
- Salt fog protection
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 6300

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

6314/2 MP 395 232 24 16...30 51 6,0 14 3 700 -20...+75 82 500 / 32 500 140 000 ➀
6314/2 NP 470 276 24 16...30 56 6,5 23 4 400 -20...+70 80 000 / 40 000 135 000 ➁
6314/2 HP 545 320 24 16...30 58 6,9 31 5 000 -20...+65 77 500 / 42 500 130 000 ➂
6318/2 HP 545 320 48 36...72 58 6,9 32 5 000 -20...+65 77 500 / 42 500 130 000 ➂
Subject to alterations
Speed control range from 1000 rpm up to maximum speed.
Standstill at 0 % PWM, maximum speed if control wire is interrupted.
* Input power at free air flow, these values can be significantly higher in the operating point.

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis. tin-pla
ted
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation 7,6 d
eep
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

78 from p. 242
Information
max. 930 m /h 3
DC axial fans
Ø 172 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 18, 20 - External temperature sensor
or AWG 22, TR 64, speed signal - Internal temperature sensor
and control input AWG 22 - PWM control input
– Highlights: Highly efficient and smoothly - Analog control input
running 3-phase fan drive - Multi-option control input
Housing with grounding lug - Humidity protection

DC centrifugal fans
for screw M4 x 8 (Torx) - Salt fog protection
– Mass: 910 g - Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 6300 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

6312/2 TDHP 600 353 12 8...16 60 7,3 40 5 500 -20...+70 75 000 / 37 500 127 500 ➁
6314/2 TDHP-298 600 353 24 16...30 60 7,3 42 5 500 -20...+65 75 000 / 42 500 127 500 ➀
6314/2 TDHP 600 353 24 16...36 60 7,3 40 5 500 -20...+75 75 000 / 30 000 127 500 ➁
6314/2 TDHHP 710 418 24 16...36 69 7,9 67 7 000 -20...+75 62 500 / 25 000 105 000 ➂

ACmaxx / EC fans
6314/2 TDH4P 930 545 24 16...36 75 8,4 150 9 200 -20...+75 52 500 / 20 000 87 500 ➄
6318/2 TDHP-299 600 353 48 36...60 60 7,3 42 5 500 -20...+65 75 000 / 42 500 127 500 ➀
6318/2 TDHP 600 353 48 36...72 60 7,3 40 5 500 -20...+75 75 000 / 30 000 127 500 ➁
6318/2 TDHHP 710 418 48 36...72 69 7,9 67 7 000 -20...+75 62 500 / 25 000 105 000 ➂
6318/2 TDH4P 930 545 48 36...72 75 8,4 150 9 200 -20...+75 52 500 / 20 000 87 500 ➃
Subject to alterations
Speed control range from 1000 rpm up to maximum speed.
Standstill at 0 % PWM, maximum speed if control wire is interrupted.

AC axial fans
* Input power at free air flow, these values can be significantly higher in the operating point.

AC centrifugal fans

* Input power - in operation


Fan type optimum
operating range (W)
6318/2 TDHHP 115
6318/2 TDH4P 270
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m; tin-pla
Sound pressure level LpA measured at 1 m distance to fan axis. ted
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation 7,6 d
eep
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
Representatives

fitted. For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
79
max. 1 100 m /h 3
DC diagonal fans
Ø 172 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: (+) and GND: AWG 18, UL 1007, - External temperature sensor
TR 64, speed signal and control - Internal temperature sensor
input AWG 22, UL 1007, TR 64 - PWM control input
– Highlights: Highly efficient and smoothly - Analog control input
running 3-phase fan drive - Multi-option control input
Housing with grounding lug - Humidity protection
for screw M4 x 8 (Torx) - Salt fog protection
– Mass: 1050 g - Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series DV 6300 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

DV 6318/2 TDHP* 630 371 48 36…72 68 7,6 75 4 000 -20…+65 70 000 / 40 000 117 500 ➀
DV 6318/2 TDHHP* 770 453 48 36…72 73 8,0 135 4 900 -20…+65 60 000 / 32 500 102 500 ➁
DV 6318/2 TDH4P 1 050 617 48 36…72 77 8,7 300 6 500 -20…+65 50 000 / 27 500 85 000 ➂
DV 6318/2 TDH5P** 1 100 647 48 36…72 79 8,9 360 6 800 -20…+65 40 000 / 22 500 67 500 ➃
Subject to alterations

* On request Speed control range from 1000 rpm up to maximum speed.


** Rotor protrusion Standstill at 0 % PWM, maximum speed if control wire is interrupted.
a = 3 mm Power boost function leeds to a higher speed & air performance in the stall area.

n Ped LwA L10 (40 °C) L10 (65 °C) L10IPC (40 °C) n Ped LwA L10 (40 °C) L10 (65 °C) L10IPC (40 °C)
rpm W dB(A) rpm W dB(A)

  4 000 65,5 79 70 000 40 000 117 500   6 500 280 90 50 000 27 500 85 000
  3 835 64,5 78 72 500 40 000 122 500   6 230 275 89 62 500 35 000 105 000
  3 815 64,5 76 75 000 42 500 127 500   6 200 280 88 70 000 40 000 117 500
  3 930 65 76 77 500 42 500 130 000   6 450 281 88 72 500 40 000 122 500
  4 240 66 79 77 500 42 500 130 000   6 900 283 92,5 72 500 40 000 122 500

  4 900 120 83 60 000 32 500 102 500   6 950 345 92 40 000 22 500 67 500
  4 690 119 82 67 500 37 500 115 000   6 720 345 91 57 500 32 500 97 500
  4 670 119 80 72 500 40 000 122 500   6 630 345 89,5 62 500 35 000 105 000
  4 870 120 81 75 000 42 500 127 500   6 850 345 89 67 500 37 500 115 000
  5 190 121 85 75 000 42 500 127 500   7 300 345 94 72 500 40 000 122 500

tin-plated

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance
to fan axis. The acoustic values are only valid for the
described measurement set-up and may vary depending 9,0 deep
on the installation situation. In case of any deviation
to the standard setup, the values have to be checked
and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

80 from p. 242
Information
max. 1 220 m /h 3
DC axial fans
220 x 200 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 18, 20 - External temperature sensor
or AWG 22, TR 64, speed signal - Internal temperature sensor
and control input AWG 22 - PWM control input
– Highlights: Highly efficient and smoothly - Analog control input
running 3-phase fan drive - Multi-option control input
Housing with grounding lug - Humidity protection

DC centrifugal fans
for screw M4 x 8 (Torx) - Salt fog protection
– Mass: 1000 g - Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series 2200 FTD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power*
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm °C Hours Hours

2214 F/2 TDHO 790 465 24 16...30 62 7,1 35 4 250 -20...+75 90 000 / 42 500 152 500 ➀
2214 F/2 TDHHO 940 553 24 16...36 66 7,4 48 5 000 -20...+70 85 000 / 42 500 142 500 ➁
2218 F/2 TDHO 790 465 48 36...57 62 7,1 35 4 250 -20...+75 90 000 / 42 500 152 500 ➀
2218 F/2 TDHHO 940 553 48 36...72 66 7,4 48 5 000 -20...+70 85 000 / 42 500 142 500 ➁

ACmaxx / EC fans
2218 F/2 TDH4P 1 220 718 48 36...72 72 8,2 103 6 500 -20...+65 70 000 / 40 000 117 500 ➂
Subject to alterations
Speed control range from 1000 rpm up to maximum speed. Standstill at 0 % PWM / 0 V,
Type O: standstill if control wire is interrupted; Type P: maximum speed if control wire is interrupted.
* Input power at free air flow, these values can be significantly higher in the operating point.

AC axial fans
AC centrifugal fans
Accessories

tin-pla
Air performance measured as per: ISO 5801, ted
Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m; 7,6 d
eep
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have to
be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
81
max. 1 245 m /h 3
DC diagonal module
 225 x 80 mm

– Material: Housing and support bracket: Fibreglass-reinforced plastic (PA6)


Impeller: Fibreglass-reinforced plastic (PA6)
Rotor: Coated in black
– Number of blades: 7
– Direction of air flow: "V"
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: A C IP 44, B D IP 20, depending on installation and position

– Insulation class: "B"


– Mounting position: Any
– Condensate discharges: A C none, B D seen on rotor

– Mode of operation: Continuous operation (S1)


– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound power level

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Mass
Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) °C kg

K1G 200-AD65-04 M1G 074-BF A 24 16...28 1 020 3 400 95 4,7 76 -25...+60 1,8 p. 262 / J5)

K1G 200-AD31-02 M1G 074-BF B 24 16...28 1 045 3 500 110 5,4 77 -25...+70 1,7 p. 262 / J5)

K1G 200-AD49-04 M1G 074-BF C 48 36...57 1 095 3 650 120 3,4 77 -25...+60 1,8 p. 262 / J5)

K1G 200-AD37-02 M1G 074-BF D 48 36...57 1 245 4 140 183 5,6 81 -25...+70 1,7 p. 262 / J5)
Subject to alterations

n Ped I L WA
in wg
Pa

Curves: rpm W A dB(A)

D A 1 3 400 95 4,70 76
500
2

A 2 3 410 116 5,61 74


A 3 3 410 119 5,75 74
A 4 3 410 117 5,62 76
400 C
B B 1 3 500 110 5,40 77
1.5

A B 2 3 510 127 6,24 75


B 3 3 510 129 6,31 75
300 B 4 3 510 125 6,15 76
C 1 3 650 120 3,40 77
1

C 2 3 645 141 3,90 75


200 C 3 3 640 145 3,99 76
C 4 3 645 141 3,88 80
D 1 4 140 183 5,60 81
0.5

100 D 2 4 080 212 6,46 79


D 3 4 060 213 6,52 79
D 4 4 105 211 6,43 80

0 100 200 300 400 500 600 700 cfm


Pfs

qv 200 400 600 800 1000 1200 m³/h


Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side
noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the
measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the
specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

82
Information
– Technical features: See electrical connections p. 262
– EMC: Interference emission acc. to EN 55022 (Class B)
Interference immunity acc. to EN 61000-6-2 (industrial environment)

DC axial fans
– Cable exit: lateral
– Protection class: I (if customer has provided connection for protective earth)
– Product conforming
to standards: EN 60335-1
– Approvals: A C UL 1004-1, CSA C22.2 Nr. 77

B D EAC, UL 1004-1, CSA C22.2 Nr. 77

DC centrifugal fans
DC fans - specials
ACmaxx / EC fans
Ø276 ±0.5
225
Ø4.6 (4x) 80 ±1
Ø288

AC axial fans
6
45°

AC centrifugal fans
4x90°

Ø2
67
.5
20
0+
35

0
±1
85
Accessories

6
"V"

Cable assignment:
Red = UN
Yellow = 0-10 VDC Connection line PVC AWG 20,
White = Speed monitoring output 4 x lead tips crimped
Blue = GND
Representatives

Electrical connections
2016-01

p. 262
83
max. 905 m /h 3
DC diagonal module
 225 x 89 mm

– Material: Housing and support bracket: Plastic PA


Impeller: Plastic PA
Rotor: Coated in black
– Number of blades: 7
– Direction of air flow: "V"
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: A C IP 44, B D IP 20, depending on installation and position

– Insulation class: "B"


– Mounting position: Any
– Condensate discharges: A C none, B D seen on rotor

– Mode of operation: Continuous operation (S1)


– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound power level

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Mass
Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) °C kg

K3G 200-BD46-04 M3G 074-CF A 24 16...28 1 240 4 120 170 7,0 80 -25...+60 2,3 p. 262 / J5)

K3G 200-BD44-02 M3G 074-CF B 24 16...28 1 445 4 830 275 11,5 84 -25...+60 2,3 p. 262 / J5)

K3G 200-BD64-04 M3G 074-CF C 48 36...57 1 475 4 875 275 5,8 85 -25...+60 2,3 p. 262 / J5)

K3G 200-BDA8-02 M3G 074-CF D 48 36...57 1 650 5 470 400 8,4 88 -25...+60 2,3 p. 262 / J5)
Subject to alterations

n Ped I L WA
in wg
Pa

Curves: rpm W A dB(A)


D
A 1 4 120 170 7,00* 80
800 A 2 4 025 180 7,52* 77
A 3 4 005 187 7,80* 76
3

B
C A 4 4 045 187 7,78* 78
B 1 4 830 275 11,50* 84
600 B 2 4 720 294 12,24* 81
B 3 4 685 299 12,48* 80
A
B 4 4 715 295 12,30* 83
2

C 1 4 875 275 5,80* 85


400
C 2 4 795 300 6,27* 81
C 3 4 755 307 6,41* 80
C 4 4 780 304 6,35* 82
1

D 1 5 470 400 8,40* 88


200
D 2 5 365 426 8,89* 85
D 3 5 310 438 9,17* 83
D 4 5 355 431 9,01* 87
* Current measured at nominal voltage.
0 200 400 600 800 1000 cfm
Pfs

qv 400 800 1200 1600 m³/h


Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side
noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the
measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the
specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

84
Informationen
– Technical features: See electrical connections p. 262
– EMV (48 V): Interference emission acc. to EN 55022 (Class B)
Interference immunity acc. to EN 61000-6-2 (industrial environment)

DC-Axiallüfter
– Cable exit: lateral
– Product conforming
to standards: EN 60335-1
– Approvals: (24 V) EAC
(48 V) EAC, CCC

DC-Radiallüfter
DC-Lüfter - Specials
ACmaxx / EC fans
225 ±0.5 83 ±1 219 ±0.5
Ø4.6 ±0.2 (4x) 6

AC axial fans
Ø2
76 ± 45°
0.5
45°

Mounting
Ø 27 dimensions
6 ±0.5

AC-Radiallüfter
Ø2
69
±0
.5
500 +20
85 ±10
8

"V"
Zubehör

Cable assignment:
Red = UN
Yellow = 0-10 VDC Connection line PVC AWG 16,
White = Speed monitoring output 4 x lead tips crimped
Blue = GND
Vertretungen

Electrical connections
2016-01

p. 262
85
max. 2 070 m /h 3
DC axial fans
Ø 250 mm

– Material: Wall ring: Die-cast aluminium


Blades: Plastic (PP)
Rotor: Thick layer passivated
– Number of blades: 7
– Direction of air flow: "V"
– Direction of rotation: Counter-clockwise, seen on rotor
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: On rotor side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Max. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A Pa °C

W1G250-HJ87 -02 M1G 074-BF A 24 16-28 2 070 3 090 120 7,00 150 -25...+60 p. 258 / E)

W1G250-HJ63 -02 M1G 074-BF B 48 36-57 2 070 3 090 120 3,40 150 -25...+60 p. 258 / E)
Subject to alterations
in H2O

n Ped I L WA
Pa

Curves: rpm W A dB(A)


B
160 A
A 1 3 090 120 6,80 74
0,6

4
A 2 2 950 124 7,10 73
140
A 3 2 820 127 7,43 73
A 4 2 730 130 7,80 78
0,5

120
B 1 3 090 120 3,40 74
B 2 2 950 124 3,55 73
3
0,4

100 B 3 2 820 127 3,74 73


B 4 2 730 130 3,90 78
80
0,3

60
2
0,2

40
0,1

20

1
pfs

0 200 400 600 800 1000 1200 cfm


qV 400 800 1200 1600 2000 m3/h

Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side
noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the
measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the
specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

86
Information
– Technical features: See electrical connections p. 258
– EMC: Interference emission acc. to EN 55022 (Class B)
Interference immunity acc. to EN 61000-6-2 (industrial environment)

DC axial fans
– Electrical connection: Via terminal strip
– Protection class: I
– Product conforming
to standards: EN 60950-1

DC centrifugal fans
DC fans - specials
ACmaxx / EC fans
For self-tapping
screws M6

AC axial fans
AC centrifugal fans
Accessories

For self-tapping "V"


screws M5
(1) Control input
(2) Speed monitoring
Representatives

Guard grilles Electrical connections


2016-01

p. 245 p. 258
87
max. 2 345 m /h 3
DC axial fans – HyBlade®
Ø 300 mm

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Plastic (PP)
Rotor: Coated in black
– Number of blades: 5
– Direction of air flow: "V"
– Direction of rotation: Counter-clockwise, seen on rotor
– Degree of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Max. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A Pa °C

*1G 300 M1G 074-CF A 24 16-28 2 320 1 830 80 3,80 100 -25..+60 p. 262 / J5)

*1G 300 M1G 074-CF B 48 36-57 2 345 1 830 80 1,90 100 -25..+60 p. 262 / J5)
Subject to alterations
in H2O

n Ped I L WA
Pa

Curves: rpm W A dB(A)


110

A 1 1 810 80 3,80 67
0,4

100
A
B A 2 1 730 86 4,03 67
90 4 4 A 3 1 690 87 4,10 66
A 4 1 635 89 4,21 70
80
B 1 1 870 87 2,00 68
0,3

70 3 B 2 1 805 90 2,10 67
B 3 1 765 91 2,13 67
60 3
B 4 1 695 92 2,19 69
0,2

50
2
40

30 2
0,1

20

10

1
pfs

0 200 400 600 800 1000 1200 cfm


qV 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 m3/h

Air performance measured as per: ISO 5801, Installation category A, in ebm-papst full nozzle and without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

88
Information
– Technical features: See electrical connections p. 262
– EMC: Interference emission acc. to EN 55022 (Class B)
Interference immunity acc. to EN 61000-6-2 (industrial environment)

DC axial fans
– Cable exit: lateral
– Product conforming
to standards: EN 60950-1, UL 1004-1, CSA C22.2 Nr. 100
– Approvals: GOST, UL

DC centrifugal fans
Mass with guard grille
Direction of air flow

for short nozzle


Mass with full
Mass without

round nozzle
attachments

DC fans - specials
"V" "V" "V"
Without With full round With guard grille
attachments kg nozzle
kg for short nozzle
kg

"V" A1G 300-AC19 -54 1,8 W1G 300-DC19 -54 3,8 S1G 300-AC19 -54 2,8

"V" A1G 300-AC33 -54 1,8 W1G 300-DC33 -54 3,8 S1G 300-AC33 -54 3,1

ACmaxx / EC fans
A1G 300 Depth of screw max. 6 mm
79±5 45°
57.5 ±3 M4 (4x)

AC axial fans
Ø300 ±1

90°
Ø92

31450 +20

75 Ø58±0.15

"V" Connection line PVC AWG 20, AC centrifugal fans


6
85±10

4 x lead tips crimped


80 Ø380
11 Ø9 (6x) 15°
60 25±3
°
(6
x)

Ø300 ±1
Ø329.6
Ø326
Ø397

Ø360

Accessories

4.5 4.3
57.2 29±5
W1G 300 S1G 300
Representatives

Electrical connections
2016-01

p. 262
89
2016-01

90
DC centrifugal fans
DC centrifugal fans

DC cross-flow blowers
DC centrifugal fan overview

DC centrifugal fans and blowers

91
140
138
95
93

2016-01

Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans DC axial fans Information
DC centrifugal fans

Technical information

Product line Voltage range


Our centrifugal product line includes fans for every application. Whether Many of our DC fans can be operated on voltages that are up to 50%
as free-running impellers with a diameter between 97 mm and 225 mm lower and 25% higher than their nominal voltage (see Voltage range in
or as assemblies in a ready-to-install, compact housing with inlet nozzle the technical tables). This enables the air performance to be adapted to
with an edge length between 51 mm and 270 mm. Of course, all models the cooling requirements and allows the noise to be reduced, even if the
feature highly efficient, brushless motor technology. fan does not have a control input.

Electronic protection against reverse polarity Closed-loop speed control and monitoring
ebm-papst DC fans have electronically commutated drives with electronic Closed-loop speed control and function monitoring are becoming
protection against reverse polarity. The electronics are conveniently increasingly important in many applications. ebm-papst offers many
located in the fan hub. fans in the standard design with a control input and open collector
speed signal.
Product life expectancy
A distinctive feature of DC fan technology is the convincing high product S-Force centrifugal – RadiCal
life expectancy. Thanks to the excellent efficiency of the brushless drives, The new S-Force centrifugal fans provide peak performance among fans
the thermal load of the bearings is reduced, thus considerably increasing of this type. With air flow capacity of over 1500 m³/h and a pressure
the life expectancy of the fans. build-up of up to 1000 pascals, the highest heat flows are manageable.
In addition, the models are extremely efficient due to the multi-pole,
Degree of protection electronically commutated drive motors and can be adapted individually
DC fans with sleeve and ball bearings are powered by class E insulated to every application thanks to intelligent motor features. Some models
motors. All ebm-papst fans conform to the requirements of degree of use our new, highly efficient RadiCal impellers.
protection IP 20. Fans conforming to IP 54 / IP 68 and special degrees of
protection are also available.
2016-01

92
Information
Centrifugal fans for DC operation
Overview of air performance

DC axial fans
Dimensions

Air flow
Series

Page
mm m3/h 10 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1 000 2 000 2 500

105 x 59 x 79 RV 40 18...24 95
c

DC centrifugal fans
51 x 15 RLF 35 9,6 96
c 76 x 27 RL 48 22...28 97
97 x 93,5 x 33 RL 65 56...61 98
c 121 x 37 RL 90 N 40...55 99
c 127 x 25 RLF 100 64...80 100
c 135 x 38 RG 90 N 55 101
c 180 x 40 RG 125 N 60...137 102
c 180 x 40 RG 140 NTD 118 NEW 103
c 220 x 56 RG 160 N 139...209 104
c 220 x 56 RG 160 NTD 59...444 105

DC fans - specials
c 226 x 85 RG 190 TD 630...930 106
c 270 x 99 RG 220 TD 1 090...1 100 107
c 270 x 119 RG 225 TD 1 040...1 450 108
Ø 97 x 41 RET 97 TD 220 109
Ø 104 x 25 REF 100 86...104 110
Ø 101 x 52 RER 101 N 162...190 111
Ø 120 x 54 RER 120 TD 320...390 112
Ø 120 R1G 120 250 114
Ø 138 x 35 RER 125 N 110...166 116

ACmaxx / EC fans
Ø 133 x 91 RER 133 TD 460...565 117
Ø 165 x 51 RER 160 N 255 118
Ø 165 x 51 RER 160 NTD 66...370 119
Ø 175 x 55 REF 175 TD 800 120
Ø 175 x 69 RER 175 TD 600...980 121
Ø 190 x 69 RER 190 TD 650...970 122
Ø 190 R3G 190 880...930 124
Ø 220 R3G 220 1 185...1 210 126
Ø 220 x 71 RER 220 TD 1 090...1 250 128

AC axial fans
Ø 225 x 99 RER 225 TD 1 190...1 600 129
Ø 225 R3G 225 1 275...1 400 130
Ø 250 R3G 250 1 640...1 650 132
Ø 280 R3G 280 2 175...2 210 134
Ø 310 R3G 310 2 380...2 420 136
201...413 x 50 x 48 QG 030 75...155 138
Ø 85 *1G 085 95 140
Ø 97 *1G 097 95 142
Ø 108 *1G 108 200 144
AC centrifugal fans
Ø 120 *1G 120 255 146
Ø 133 *1G 133 225 148
Ø 140 *1G 140 400...410 150
Ø 146 *1G 146 465...470 152
Ø 160 *1G 160 505 154
Ø 133 D1G 133 700 156
Ø 133 D1G 133 1 020 158
Ø 146 D1G 146 1 000 160
Ø 160 D1G 160 980 162
Accessories

Subject to alterations

10 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1 000 2 000 2 500
m3/h
Representatives
2016-01

93
Centrifugal fans for DC operation
Overview of technically feasible designs

gs
earin

re se r
nsor
o
sens
all b

ut
l inp
gs/b

d
ture
spee

ut

tion
o
in

t
eratu

tion
l inp

r
larm

cont
pera
bear

l inp

c
limit

rotec
ntro

prot
emp
Go-a

m
CSA

nal

tion
eve
ns

r
e
with

cont
g co

fog p
t
d sig
ensio

= 54
c sle

idity
nal t

i-op
/ No

rnal
, UL,

Alarm

Analo
PWM

IP 68

Page
Hum
Spee
Sinte

Mult
Inter
Exte

IP >
Dim

Salt
Go-
VDE

Please note that these special versions are not possible


Centrifugal fans
mm Series OPTIONAL p. for all voltages and speeds, and not in all combinations.
105 x 59 x 79 RV 40 • • – – – – – – – • – – – 95 The special versions are designed for specific customers
c 51 x 15 RLF 35 yes • – – – – • – – • – – – 96 and projects. As a rule they are not available off the
c 76 x 27 RL 48 yes • • • • • • • – • – – – 97
shelf and are subject to minimum volumes.
97 x 93,5 x 33 RL 65 yes • • • • • • • – • – – – 98
c 121 x 37 RL 90 N yes / • • • • • • • – • • • • 99
c 127 x 25 RLF 100 yes • • • • • • • – • • – – 100
Please consult your customer support representative
c 135 x 38 RG 90 N yes / • • • • • • • – • • • • 101 about the feasibility of your special variant.
c 180 x 40 RG 125 N yes • • • • • • • – • • • • 102
NEW c 180 x 40 RG 140 NTD yes • • • • – • • • • • • • 103
c 220 x 56 RG 160 N yes • • • • • • • – • • – • 104
c 220 x 56 RG 160 NTD yes • • • • • • • – • • – • 105
c 226 x 85 RG 190 TD yes • • • • • • • • • • – • 106
c 270 x 99 RG 220 TD yes • • • • • • • – • • – • 107
c 270 x 132 RG 225 TD yes • • • • • • • – • • – • 108
Ø 97 x 41 RET 97 TD yes • • • • • • • – • – – – 109
Ø 100 x 25 REF 100 yes • • • • • • • – • • – – 110
Ø 101 x 52 RER 101 N yes • • • • • • • – • – – – 111
Ø 120 x 54 RER 120 TD yes • • • • • • • – • – – – 112
Ø 138 x 35 RER 125 N yes • • • • • • • – • • • • 116
Ø 133 x 91 RER 133 TD yes • • • • • • • • • • – • 117
Ø 165 x 51 RER 160 N yes • • • • • • • – • • – • 118
Ø 165 x 51 RER 160 NTD yes • • • • • • • – • • – – 119
Ø 175 x 55 REF 175 TD yes • • • • • • • • • • – – 120
Ø 175 x 69 RER 175 TD yes • • • • • • • • • • – • 121
Ø 190 x 69 RER 190 TD yes • • • • • • • • • • – • 122
Ø 220 x 71 RER 220 TD yes • • • • • • • • • • – • 128
Ø 225 x 99 RER 225 TD yes • • • • • • • • • • – • 129
201...413 x 50 x 48 QG 030 yes / • – – – – – – – • – – – 138
Subject to alterations

– not yet available Sleeve bearings


• available Ball bearings

Optional special versions (see page 12)


On the catalogue pages and in the overview on page 12, we provide versions are designed for specific customers and projects and are not
information about the special designs that are technically feasible in available off the shelf usually.
the fan series. Please note that these special versions are not possible
for all voltages and speeds, and not in all combinations. The special
2016-01

94
Information
max. 24 m /h 3
DC centrifugal fans
105 x 59 x 79 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
– Direction of air flow: Axial: Intake - Speed signal

DC axial fans
Centrifugal: Exhaust - Humidity protection
– Connection: Via single wires AWG 26,
TR 64
– Highlights: Forwards-curved impeller
– Mass: 100 g

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RV 40

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RV 40-18/12 L 18 10,6 12 9...16 4,0 2,0 3 900 -20...+70 70 000 / 35 000 117 500 ➀
RV 40-18/12 H 24 14,1 12 9...16 5,0 4,5 4 800 -20...+70 50 000 / 25 000 85 000 ➁
Subject to alterations

ACmaxx / EC fans
AC axial fans
AC centrifugal fans

Ø 30 Ø 31 2,3
18
4,2 (2x)

Air performance measured as per: ISO 5801,


Installation category A, without accidental 10,5
60,4

Accessories

contact.
45,78

Noise: Total sound power level LWA ISO


103002 measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m 27
opening
Intake

Ø 40
Ø 46,5

distance to fan axis.


The acoustic values are only valid for the
described measurement set-up and may vary
42,04

depending on the installation situation.


In case of any deviation to the standard
setup, the values have to be checked and 18,35
reviewed once installed or fitted.
For detailed information see
36,35 12 2,51
Representatives

http://www.ebmpapst.com/general
conditions 58,85 44,9 32,4
2016-01

95
max. 9,6 m /h 3
DC centrifugal fans
 51 x 15 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
– Direction of air flow: Axial: Intake - Speed signal
Centrifugal: Exhaust - PWM control input
– Connection: Via single wires AWG 26, - Humidity protection
TR 64
– Highlights: Forwards-curved impeller
– Mass: 40 g

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RLF 35

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RLF 35-8/12 N 9,6 5,7 12 8...13,2 5,5 3,5 6 700 -20...+70 60 000 / 30 000 102 500 ➀
RLF 35-8/14 N 9,6 5,7 24 14...28 5,5 4,3 6 700 -20...+70 60 000 / 30 000 102 500 ➀
Subject to alterations

tin-pla
ted

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values
have to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions
2016-01

96
Information
max. 28 m /h 3
DC centrifugal fans
 76 x 27 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
– Direction of air flow: Axial: Intake - Speed signal

DC axial fans
Centrifugal: Exhaust - Go- / NoGo-alarm
– Connection: Via single wires AWG 26, - Alarm with limit speed
TR 64 - External temperature sensor
– Highlights: Forwards-curved impeller - Internal temperature sensor
– Mass: 75 g - PWM control input
- Analog control input
- Humidity protection

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RL 48

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RL 48-19/12 ML 22 12,9 12 8...15 5,3 5,0 3 500 -20...+70 70 000 / 35 000 117 500 ➀
RL 48-19/12 28 16,5 12 8...13,5 5,7 4,6 4 400 -20...+70 60 000 / 30 000 102 500 ➁
RL 48-19/14 ML 22 12,9 24 18...28 5,3 5,0 3 500 -20...+70 70 000 / 35 000 117 500 ➀
RL 48-19/14 28 16,5 24 18...26,4 5,7 4,4 4 400 -20...+70 60 000 / 30 000 102 500 ➁

ACmaxx / EC fans
Subject to alterations

AC axial fans
AC centrifugal fans

tin-plate
d
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values
have to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions
2016-01

97
max. 61 m /h
3
DC centrifugal fans
97 x 93,5 x 33 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
– Direction of air flow: Axial: Intake - Speed signal
Centrifugal: Exhaust - Go- / NoGo-alarm
– Connection: Via single wires AWG 26, - Alarm with limit speed
TR 64 - External temperature sensor
– Highlights: Forwards-curved impeller - Internal temperature sensor
– Mass: 170 g - PWM control input
- Analog control input
- Humidity protection

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RL 65

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RL 65-21/12 56 33 12 6,8...13,8 6,6 15,0 4 500 -20...+70 60 000 / 30 000 102 500 ➀
RL 65-21/12 H 61 36 12 6,8...13,2 6,8 19,2 4 900 -20...+55 55 000 / 40 000 92 500 ➁
RL 65-21/14 56 33 24 12...26,4 6,6 14,0 4 500 -20...+70 60 000 / 30 000 102 500 ➀
RL 65-21/14 H 61 36 24 12...26,4 6,8 18,0 4 900 -20...+60 55 000 / 35 000 92 500 ➁
Subject to alterations

Snap-in fins
Snap-in fins for
for
easy latch
easy assembly

tin-plate
d

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values
have to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions
2016-01

98
Information
max. 55 m /h 3
DC centrifugal fans
 121 x 37 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
Base plate: Sheet steel - Speed signal

DC axial fans
– Direction of air flow: Axial: Intake - Go- / NoGo-alarm
Centrifugal: Exhaust - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Forwards-curved impeller - PWM control input
– Mass: 420 g - Analog control input
- Humidity protection
- Salt fog protection

DC centrifugal fans
- Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RL 90 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RL 90-18/12 N 40 23,5 12 7...15 5,8 6,3 2 500 -30...+75 62 500 / 27 500 105 000 ➀
RL 90-18/14 NG 40 23,5 24 12...28 5,8 5,6 2 500 -20...+75 62 500 / 27 500 105 000 ➀
RL 90-18/14 N 40 23,5 24 12...28 5,8 5,6 2 500 -30...+75 62 500 / 27 500 105 000 ➀

ACmaxx / EC fans
RL 90-18/18 NH 55 32,4 48 36...53 6,9 14,7 3 500 -30...+65 32 500 / 17 500 55 000
Subject to alterations

AC axial fans
AC centrifugal fans

37,3 + 0,7
3,5
60,3 26,5
45 2

Air performance measured as per: ISO 5801,


Installation category A, without accidental
Accessories

contact.
310 +10

104,8 + 0,2

Noise: Total sound power level LWA ISO


57,6

120,6
80

103002 measured on half-sphere of 2 m;


71,4 + 0,2

67,4 + 0,4
97

Sound pressure level LpA measured at 1 m


6+1

2,5

54

distance to fan axis.


The acoustic values are only valid for the
described measurement set-up and may
vary depending on the installation situation. tin-plated
12±0,5

In case of any deviation to the standard 4,2 + 0,4


6+ 0,3

setup, the values have to be checked and 15,5


reviewed once installed or fitted. 100,8 + 0,2 30+_ 0,3
For detailed information see 112,7 + 0,2
120,6
Representatives

http://www.ebmpapst.com/general
conditions Screw clip M4 or 8-32UNC. Screw-in depth max. 12.5 min. 9.0
2016-01

99
max. 80 m /h
3
DC centrifugal fans
 127 x 25 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
Base plate: Sheet steel - Speed signal
– Direction of air flow: Axial: Intake - Go- / NoGo-alarm
Centrifugal: Exhaust - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Optional protective cap for - PWM control input
outlet opening - Analog control input
Backwards-curved impeller - Humidity protection
– Mass: 320 g - Degree of protection: IP 54

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RLF 100

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RLF 100-11/12 64 37,7 12 8...15 6,4 8,0 5 100 -20...+75 80 000 / 30 000 135 000 ➀
RLF 100-11/14 64 37,7 24 16...30 6,4 8,0 5 100 -20...+75 80 000 / 30 000 135 000 ➀
RLF 100-11/18 64 37,7 48 36...60 6,4 8,6 5 100 -20...+75 80 000 / 30 000 135 000 ➀

High speed models with Open Collector Tacho and PWM speed control.
RLF 100-11/12/2 HP-200 80 47,1 12 10...13,2 7,5 18,6 6 400 -20...+60 72 500 / 45 000 122 500 ➁
RLF 100-11/18/2 HP-182 80 47,1 48 43...53 7,5 17,0 6 400 -20...+70 72 500 / 35 000 122 500 ➁
Subject to alterations

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002 tin-pla
measured on half-sphere of 2 m; ted
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have to
be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions
2016-01

100
Information
max. 55 m /h 3
DC centrifugal fans
 135 x 38 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
Base plate: Sheet steel - Speed signal

DC axial fans
– Direction of air flow: Axial: Intake - Go- / NoGo-alarm
Centrifugal: Exhaust - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
48 V model: Flat plug - PWM control input
6.3 x 0.8 mm for protective earth - Analog control input
– Highlights: Forwards-curved impeller - Humidity protection
– Mass: 440 g - Salt fog protection

DC centrifugal fans
- Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RG 90 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RG 90-18/12 N 55 32,4 12 7...15 5,5 6,7 2 200 -30...+75 62 500 / 27 500 105 000 ➀
RG 90-18/14 NG 55 32,4 24 12...28 5,5 6,2 2 200 -10...+75 62 500 / 27 500 105 000 ➀
RG 90-18/14 N 55 32,4 24 12...28 5,5 6,2 2 200 -30...+75 62 500 / 27 500 105 000 ➀

ACmaxx / EC fans
RG 90-18/18 N 55 32,4 48 36...56 5,5 6,1 2 200 -30...+75 62 500 / 27 500 105 000
Subject to alterations

AC axial fans
AC centrifugal fans
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m; tin-pla
Sound pressure level LpA measured at 1 m distance to fan axis. ted
The acoustic values are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have to
be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions
2016-01

101
max. 137 m /h 3
DC centrifugal fans
 180 x 40 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
Base plate: Sheet steel - Speed signal
– Direction of air flow: Axial: Intake - Go- / NoGo-alarm
Centrifugal: Exhaust - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
48 V model: Flat plug - PWM control input
6.3 x 0.8 mm for protective earth - Analog control input
– Highlights: Backwards-curved impeller - Humidity protection
– Mass: 730 g - Salt fog protection
- Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RG 125 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RG 125-19/12 NM 60,0 35,3 12 7...15 4,8 2,0 1 750 -30...+75 70 000 / 30 000 117 500 ➀
RG 125-19/12 N 87,5 51,5 12 7...15 5,8 5,2 2 550 -30...+75 62 500 / 27 500 105 000 ➁
RG 125-19/14 NM 60,0 35,3 24 12...28 4,8 2,0 1 750 -30...+75 70 000 / 30 000 117 500 ➀
RG 125-19/14 N 87,5 51,5 24 12...28 5,8 4,9 2 550 -30...+75 62 500 / 27 500 105 000 ➁
RG 125-19/18 N 87,5 51,5 48 36...56 5,8 4,8 2 550 -30...+75 62 500 / 27 500 105 000 ➁
RG 125-19/18 NH 137 80,6 48 36...56 7,0 19,0 4 000 -20...+70 55 000 / 27 500 92 500 ➂
Subject to alterations

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
tin-p
The acoustic values are only valid for the described measurement lated
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have to
be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions
2016-01

102
Information
max. 118 m /h 3
DC centrifugal fans
 180 x 40 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
Base plate: Sheet steel - Speed signal

DC axial fans
– Direction of air flow: Axial: Intake - Go / No-go alarm
Centrifugal: Exhaust - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - PWM control input
– Highlights: Backwards-curved impeller - Analog control input
3-phase fan drive with special - Multi-option control input
commutation electronic for - Humidity protection
extremely low-noise operation - Salt fog protection

DC centrifugal fans
– Mass: 750 g - Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RG 140 NTD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

NEW RG 140-22/14 N/2 TDPU 118 69,4 24 20,4...27,6 6,0 9,3 2 500 -20...+70 62 500 / 32 500 105 000 ➀
Subject to alterations

Higher performance levels on request.

ACmaxx / EC fans
AC axial fans
n Ped LWA
rpm W dB(A)

  2 504 9 61 AC centrifugal fans


  2 504 9 61
  2 504 9 62
  2 504 9 64

200
0,7
0,6

150
Accessories
0,5
0,4

100 Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
0,3

Noise: Total sound power level LWA ISO 103002


measured on half-sphere of 2 m;
0,2

50 Sound pressure level LpA measured at 1 m distance to fan axis.


tin-p
The acoustic values are only valid for the described measurement lated
0,1

set-up and may vary depending on the installation situation.


In case of any deviation to the standard setup, the values have to
0 10 20 30 40 50 60 cfm be checked and reviewed once installed or fitted.
Representatives

For detailed information see


20 40 60 80 100 http://www.ebmpapst.com/general conditions
2016-01

103
max. 209 m /h 3
DC centrifugal fans
 220 x 56 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
Base plate: Sheet steel - Speed signal
– Direction of air flow: Axial: Intake - Go- / NoGo-alarm
Centrifugal: Exhaust - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
48 V model: Flat plug - PWM control input
6.3 x 0.8 mm for protective earth - Analog control input
– Highlights: Backwards-curved impeller - Humidity protection
– Mass: 1,4 kg - Salt fog protection
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RG 160 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RG 160-28/12 NM 139 81 12 7...14 5,6 7,5 1 900 -20...+70 80 000 / 40 000 135 000 ➀
RG 160-28/12 N 209 123 12 7,5...14 6,6 21,0 2 850 -20...+70 70 000 / 35 000 117 500 ➁
RG 160-28/14 NM 139 81 24 12...28 5,6 7,0 1 900 -20...+70 80 000 / 40 000 135 000 ➀
RG 160-28/14 N 209 123 24 12...28 6,6 20,0 2 850 -20...+70 70 000 / 35 000 117 500 ➁
RG 160-28/18 N 209 123 48 28...60 6,6 20,0 2 850 -20...+70 70 000 / 35 000 117 500 ➁
Subject to alterations

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
tin-pla
The acoustic values are only valid for the described measurement ted
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have to
be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions
2016-01

104
Information
max. 444 m /h 3
DC centrifugal fans
 220 x 56 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
Base plate: Sheet steel - Speed signal

DC axial fans
– Direction of air flow: Axial: Intake - Go- / NoGo-alarm
Centrifugal: Exhaust - Alarm with limit speed
– Connection: Via single wires AWG 22, TR 64 - External temperature sensor
48 V model: Flat plug - Internal temperature sensor
6.3 x 0.8 mm for protective earth - PWM control input
– Highlights: Smoothly running 3-phase - Analog control input
fan drive - Humidity protection
Backwards-curved impeller - Degree of protection: IP 54

DC centrifugal fans
– Mass: 1,4 kg
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RG 160 NTD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

min. 59 35 — 2,0 800 ➀


RG 160-28/14 NTD... 24 16...28 -20...+60 55 000 / 35 000 92 500
max. 308 181 7,5 64,0 4 200 ➁
RG 160-28/14 NTD 308 181 24 16...28 7,5 64,0 4 200 -20...+60 55 000 / 35 000 92 500 ➁
RG 160-28/14 NTDH 370 218 24 16...28 7,8 101,0 5 000 -20...+60 50 000 / 32 500 85 000 ➂

ACmaxx / EC fans
min. 59 35 — 2,0 800 ➀
RG 160-28/18 NTD... 48 38...57 -20...+70 55 000 / 27 500 92 500
max. 308 181 7,5 59,0 4 200 ➁
RG 160-28/18 N/2 TDHHP* 444 261 48 36...60 8,5 159 6 000 -20...+65 40 000 / 22 500 67 500 ➃
Subject to alterations
Models RG 160-28/14 NTD... and RG 160-28/18 NTD... are available in customer-specific, custom-developed variants only.
The data specified here are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs
and control inputs.
*The specific service life is valid when an external capacitor is wired between the plus and minus wires.

AC axial fans
Please note the wiring suggestion.

AC centrifugal fans
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measurement tin-pla
ted
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have to
be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions
2016-01

105
max. 930 m /h 3
DC centrifugal fans
 226 x 85 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
– Direction of air flow: Axial: Intake, Centrifugal: Exhaust - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 18, 20 or - Alarm with limit speed
AWG 22, TR 64, speed signal - External temperature sensor
and control input AWG 22 - Internal temperature sensor
– Highlights: Highly efficient and smoothly - PWM control input
running 3-phase fan drive - Analog control input
Backwards-curved RadiCal - Multi-option control input
impeller - Humidity protection
– Mass: 1210 g - Salt fog protection
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RG 190 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RG 190-39/14/2 TDMLO 630 371 24 16...30 7,6 54 3 000 -20...+60 55 000 / 35 000 92 500 ➀
RG 190-39/14/2 TDMO 820 482 24 16...36 7,9 113 3 900 -20...+65 52 500 / 30 000 87 500 ➁
RG 190-39/18/2 TDMLO* 630 371 48 36...57 7,6 52 3 000 -20...+65 55 000 / 30 000 92 500 ➀
RG 190-39/18/2 TDMO 820 482 48 36...72 7,9 113 3 900 -20...+65 52 500 / 30 000 87 500 ➁
RG 190-39/18/2 TDO 930 547 48 36...72 8,3 140 4 400 -20...+65 40 000 / 22 500 67 500 ➂
* On request
Subject to alterations Speed control range from 800 rpm up to maximum speed. Standstill at 0 % PWM / 0 V,
Type O: Standstill if control wire is interrupted. see p. 180.

tin-plated

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

106 p. 249
Information
max. 1 100 m /h 3
DC centrifugal fans – RadiCal
 270 x 99 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
– Direction of air flow: Axial: Intake - Speed signal

DC axial fans
Centrifugal: Exhaust - Go- / NoGo-alarm
– Direction of rotation: Clockwise, seen on rotor - Alarm with limit speed
– Connection: Via single wires AWG 18, 20 or - External temperature sensor
AWG 22, TR 64, speed signal - Internal temperature sensor
and control input AWG 22 - PWM control input
– Highlights: Highly efficient and smoothly - Analog control input
running 3-phase fan drive - Humidity protection
Backwards-curved impeller - Salt fog protection

DC centrifugal fans
– Mass: 1560 g - Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RG 220 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RG 220-43/14/2 TDMO 1 100 647 24 16...36 7,5 101 3 000 -20...+55 55 000 / 40 000 92 500 ➀
RG 220-43/18/2 TDMO* 1 100 647 48 36...72 7,5 101 3 000 -20...+55 55 000 / 40 000 92 500 ➀
* On request
Subject to alterations
Speed control range from 800 rpm up to maximum speed. Standstill at 0 % PWM / 0 V,
Type O: Standstill if control wire is interrupted. see p. 180.

ACmaxx / EC fans
Further types available on request.

AC axial fans
AC centrifugal fans
Pa

in H O
2

500
tin-plated
1,75

400
1,5

Accessories
1,25

300
1,0

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
200
0,75

Noise: Total sound power level LWA ISO 103002


measured on half-sphere of 2 m;
0,5

Sound pressure level LpA measured at 1 m distance to fan axis.


100 The acoustic values are only valid for the described measure-
0,25

ment set-up and may vary depending on the installation


situation. In case of any deviation to the standard setup, the
0 100 200 300 400 500 600 cfm
values have to be checked and reviewed once installed or
Representatives

fitted. For detailed information see


200 400 600 800 1000 m3/h
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

p. 249
107
max. 1 450 m /h 3
DC centrifugal fans – RadiCal
 270 x 119 mm

– Material: Scroll housing: GRP1) – Possible special versions:


Impeller: GRP1) (See chapter DC fans - specials)
– Direction of air flow: Axial: Intake, Centrifugal: Exhaust - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 18, 20 or - Alarm with limit speed
AWG 22, TR 64, speed signal - External temperature sensor
and control input AWG 22 - Internal temperature sensor
– Highlights: Highly efficient and smoothly - PWM control input
running 3-phase fan drive - Analog control input
Backwards-curved RadiCal - Humidity protection
impeller - Salt fog protection
– Mass: 1750 g - Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RG 225 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RG 225-55/14/2 TDMLO 1 090 641 24 16...36 7,4 80 2 500 -20...+65 52 500 / 30 000 87 500 ➀
RG 225-55/18/2 TDMLO* 1 090 641 48 36...72 7,4 80 2 500 -20...+65 52 500 / 30 000 87 500 ➀
RG 225-55/18/2 TDMO 1 210 712 48 36...72 7,9 116 2 800 -20...+55 55 000 / 40 000 92 500 ➁
RG 225-55/18/2 TDO 1 450 853 48 36...60 8,1 192 3 300 -20...+40 30 000 / 30 000 50 000 ➂
* On request
Subject to alterations
Speed control range from 800 rpm up to maximum speed. Standstill at 0 % PWM / 0 V,
Type O: Standstill if control wire is interrupted. see p. 180.
The specific service life is valid when an external capacitor is wired between the plus and minus wires.
Please note the wiring suggestion.

tin-plated

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

108 p. 249
Information
max. 220 m /h 3
DC centrifugal fans
Ø 97 x 41 mm

– Material: Impeller: Galvanised sheet – Possible special versions:


steel (See chapter DC fans - specials)
– Direction of air flow: Axial: Intake, Centrifugal: Exhaust - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 18, 20 or - Alarm with limit speed
AWG 22, TR 64, speed signal - External temperature sensor
and control input AWG 22 - Internal temperature sensor
– Highlights: Highly efficient and smoothly - PWM control input
running 3-phase fan drive - Analog control input
Forwards-curved impeller - Humidity protection
Fan requires a scroll housing

DC centrifugal fans
– Mass: 430 g

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RET 97 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RET 97-25/14/2 TDP 220 129 24 16...32 8,1 77 6 000 -20...+60 80 000 / 50 000 135 000 ➀
RET 97-25/18/2 TDP 220 129 48 36...60 8,1 76 6 000 -20...+60 80 000 / 50 000 135 000 ➀
Subject to alterations
Speed control range from 800 rpm up to maximum speed. Standstill at 0 % PWM,
Type P: maximum speed if control wire is interrupted.

ACmaxx / EC fans
The specific service life is valid when an external capacitor is wired between the plus and minus wires.
Please note the wiring suggestion.

AC axial fans
AC centrifugal fans
6 +1

tin-plated
310 +10

Accessories

Air performance measured as per: ISO 5801,


ø 58,3
ø 47,1

Installation category A, with ebm-papst spiral housing without


97

protection against accidental contact.


Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
M4 (4x)

The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
24,4
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or fitted. 7,95 + 1
40,5 +1
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Inlet nozzles
2016-01

from p. 252
109
max. 104 m /h 3
DC centrifugal fans
Ø 104 x 25 mm

– Material: Impeller: GRP1) – Possible special versions:


– Direction of air flow: Axial: Intake (See chapter DC fans - specials)
Centrifugal: Exhaust - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Alarm with limit speed
TR 64 - External temperature sensor
– Highlights: Backwards-curved impeller - Internal temperature sensor
– Mass: 160 g - PWM control input
- Analog control input
- Humidity protection
- Degree of protection: IP 54

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series REF 100

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

REF 100-11/12 86 50,6 12 8...15 6,3 7,5 5 400 -20...+75 80 000 / 30 000 135 000 ➀
REF 100-11/14 86 50,6 24 16...30 6,3 7,5 5 400 -20...+75 80 000 / 30 000 135 000 ➀
REF 100-11/18 86 50,6 48 36...60 6,3 8,2 5 400 -20...+75 80 000 / 30 000 135 000 ➀
REF 100-11/18 H 104 61,2 48 36...56 6,9 14,8 6 700 -20...+70 67 500 / 32 500 115 000 ➁
Subject to alterations

The air flow and noise level of the centrifugal fans without
external housing depend on their individual installation
conditions. The stated air flow and noise level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate 127 x 127 mm.
Cover plate 127 x 127 mm, with an air inlet opening Ø 70 mm,
arranged concentrically to the impeller.

tin-pla
ted

Air performance measured as per: ISO 5801,


Installation category A, with ebm-papst inlet nozzle without
protection against accidental contact.
Noise: Total sound power level LWA ISO 103002
measuredon half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis
The acoustic values given are only valid for the described measure-
ment set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have to
6 deep

be checked and reviewed once installed or fitted.


For detailed information see
http://www.ebmpapst.com/general conditions
2016-01

110
Information
max. 190 m /h 3
DC centrifugal fans
Ø 101 x 52 mm

– Material: Impeller: GRP1) – Possible special versions:


– Direction of air flow: Axial: Intake (See chapter DC fans - specials)
Centrifugal: Exhaust - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Alarm with limit speed
TR 64 - External temperature sensor
– Highlights: Backwards-curved impeller - Internal temperature sensor
– Mass: 305 g - PWM control input
- Analog control input
- Humidity protection

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RER 101 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RER 101-36/12 NH 162 95 12 9...13,6 6,9 13,0 5 000 -20...+70 65 000 / 32 500 110 000 ➁
RER 101-36/12 NHH 190 112 12 9...13,6 7,2 20,5 6 000 -20...+70 60 000 / 30 000 102 500 ➀
RER 101-36/14 NHH 190 112 24 18...27,2 7,2 22,5 6 050 -20...+70 60 000 / 30 000 102 500 ➀

ACmaxx / EC fans
RER 101-36/18 NHH 190 112 48 36...60 7,2 19,4 5 850 -20...+70 60 000 / 30 000 102 500 ➀
Subject to alterations

The air flow and noise level of the centrifugal fans without
external housing depend on their individual installation
conditions. The stated air flow and noise level were recorded
under the following measurement parameters:

AC axial fans
Centrifugal fan mounted on a foundation plate 148 x 148 mm.
Cover plate 148 x 148 mm, with an air inlet opening Ø 66 mm,
arranged concentrically to the impeller.

AC centrifugal fans

tin-p
lated
36,7
Accessories
O 100 +- 0,5
O 60 +- 0,2

Air performance measured as per: ISO 5801,


Installation category A, with ebm-papst inlet nozzle without
protection against accidental contact.
Noise: Total sound power level LWA ISO 103002
measuredon half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis
The acoustic values given are only valid for the described
measurement set-up and may vary depending on the 6,0 +- 0,2
M 4 (3x)
10 deep

installation situation. 7,0 +- 0,45


In case of any deviation to the standard setup, the values have 8,0 +- 0,55
to be checked and reviewed once installed or fitted.
50,25 +- 0,95
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions 51,7 +- 0,9
2016-01

111
max. 390 m /h 3
DC centrifugal fans
Ø 120 x 54 mm

– Material: Impeller: GRP1) – Possible special versions:


– Direction of air flow: Axial: Intake (See chapter DC fans - specials)
Centrifugal: Exhaust - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 18, 20 or - Alarm with limit speed
AWG 22, TR 64, speed signal - External temperature sensor
and control input AWG 22 - Internal temperature sensor
– Highlights: Highly efficient and smoothly - PWM control input
running 3-phase fan drive - Analog control input
Backwards-curved impeller - Humidity protection
– Mass: 430 g

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RER 120 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RER 120-26/14/2 TDMP* 320 188 24 16...32 tbd 51 5 200 -20...+60 60 000 / 37 500 102 500 ➀
RER 120-26/14/2 TDP 377 222 24 16...32 8,2 78 6 100 -20...+60 55 000 / 35 000 92 500 ➁
RER 120-26/18/2 TDMP* 320 188 48 36...60 tbd 51 5 200 -20...+60 57 500 / 35 000 97 500 ➀
RER 120-26/18/2 TDP 390 230 48 36...60 8,3 92 6 300 -20...+60 50 000 / 30 000 85 000 ➂
* On request
Subject to alterations
Speed control range from 800 rpm up to maximum speed. Standstill at 0 % PWM.
Type P: maximum speed if control wire is interrupted.
The specific service life is valid when an external capacitor is wired between the plus and minus wires.
Please note the wiring suggestion.

The air flow and noise level of the centrifugal fans without
external housing depend on their individual installation
conditions. The stated air flow and noise level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate 140 x 140 mm.
Cover plate 140 x 140 mm, with an air inlet opening Ø 94,4 mm,
arranged concentrically to the fan impeller.

tin-plated

Air performance measured as per: ISO 5801,


Installation category A, with ebm-papst inlet nozzle without
protection against accidental contact.
Noise: Total sound power level LWA ISO 103002
max. 8 deep

measuredon half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values given are only valid for the described measure-
ment set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have to
be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Inlet nozzles
2016-01

112 from p. 252


113
2016-01

Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans DC axial fans Information
max. 250 m /h 3
DC centrifugal fans
Ø 120 mm

– Material: Impeller: PA 6.6 plastic, fibreglass-reinforced


Rotor: Galvanised
– Number of blades: 9
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 20
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound pressure level

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) °C

R1G 120 M1G 045-BE A 24 16-28 250 4 060 26 1,20 62 -25..+50 p. 259 / G)

R1G 120 M1G 045-BE A 48 36-57 250 4 060 26 0,60 62 -25..+50 p. 259 / G)
Subject to alterations

n Ped LpA htL


Curves: rpm W dB(A) %

UN = nominal A 1’ 4 520 36 65 —
voltage A 2’ 4 500 36 64 27
(24 V /48 V) A 3’ 4 540 36 61 45
A 4’ 4 750 32 64 39
UR = overvoltage A 1 4 060 26 62 —
(28 V / 57 V) A 2 4 000 26 61 27
A 3 4 050 26 58 45
A 4 4 200 23 61 39
A 5 3 270 14 56 —
A 6 3 250 14 55 27
A 7 3 280 14 53 45
A 8 3 400 13 56 39

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

114
Information
– Technical features: See electrical connections p. 259
– Cable exit: Axial
– Product conforming

DC axial fans
to standards: EN 60950-1
– Approvals: EAC

DC centrifugal fans
centrifugal fans

DC fans - specials
Mass

Inlet nozzle
Centrifugal fans kg (long)

R1G 120-AD13 -02 0,5 96120-2-4013

R1G 120-AD11 -02 0,5 96120-2-4013

ACmaxx / EC fans
Depth of screw
max. 4 mm

AC axial fans
Lead tips crimped

AC centrifugal fans
Accessories
Representatives

Inlet nozzles Electrical connections


2016-01

p. 253 p. 259
115
max. 166 m /h 3
DC centrifugal fans
Ø 138 x 35 mm

– Material: Impeller: GRP1) – Possible special versions:


– Direction of air flow: Axial: Intake (See chapter DC fans - specials)
Centrifugal: Exhaust - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Alarm with limit speed
TR 64 - External temperature sensor
– Highlights: Backwards-curved impeller - Internal temperature sensor
– Mass: 320 g - PWM control input
- Analog control input
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RER 125 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RER 125-19/12 N 110 64,7 12 7...15 5,7 4,6 2 650 -30...+75 62 500 / 27 500 105 000 ➀
RER 125-19/14 N 110 64,7 24 12...28 5,7 4,3 2 650 -30...+75 62 500 / 27 500 105 000 ➀
RER 125-19/14 NH 166 97,7 24 12...28 7,0 13,0 4 000 -20...+70 55 000 / 27 500 92 500 ➁
RER 125-19/18 N 110 64,7 48 36...56 5,7 4,2 2 650 -30...+75 62 500 / 27 500 105 000 ➀
Subject to alterations

The air flow and noise level of the centrifugal fans without
external housing depend on their individual installation
conditions. The stated air flow and noise level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate 120 x 120 mm.
Cover plate 120 x 120 mm, with an air inlet opening Ø 86 mm,
arranged concentrically to the impeller.
5 deep

Air performance measured as per: ISO 5801,


Installation category A, with ebm-papst inlet nozzle without
protection against accidental contact.
Noise: Total sound power level LWA ISO 103002
measuredon half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values given are only valid for the described measure-
ment set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have to
be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions tin-plated
2016-01

116
Information
max. 565 m /h 3
DC centrifugal fans
Ø 133 x 91 mm

– Material: Impeller: GRP1) – Possible special versions:


– Direction of air flow: Axial: Intake (See chapter DC fans - specials)
Centrifugal: Exhaust - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 18, 20 or - Alarm with limit speed
AWG 22, TR 64, speed signal - External temperature sensor
and control input AWG 22 - Internal temperature sensor
– Highlights: Highly efficient and smoothly - PWM control input
running 3-phase fan drive - Analog control input
Backwards-curved impeller - Multi-option control input
– Mass: 890 g - Humidity protection

DC centrifugal fans
- Salt fog protection
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RER 133 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RER 133-41/14/2 TDMP 460 271 24 16...30 tbd 58 5 000 -20...+65 72 500 / 40 000 122 500 ➀
RER 133-41/14/2 TDP* 565 332 24 16...36 tbd 90 6 000 -20...+65 70 000 / 37 500 117 500 ➁
RER 133-41/18/2 TDMP* 460 271 48 36...57 tbd 50 5 000 -20...+65 72 500 / 40 000 122 500 ➀
RER 133-41/18/2 TDP 565 332 48 36...72 8,2 87 6 000 -20...+65 70 000 / 37 500 117 500 ➁

ACmaxx / EC fans
* On request
Subject to alterations
Speed control range from 800 rpm up to maximum speed. Standstill at 0 % PWM
Type P: maximum speed if control wire is interrupted.

The air flow and noise level of the centrifugal fans without
external housing depend on their individual installation
conditions. The stated air flow and noise level were recorded
under the following measurement parameters:

AC axial fans
Centrifugal fan mounted on a foundation plate 140 x 140 mm.
Cover plate 140 x 140 mm, with an air inlet opening Ø 87 mm,
arranged concentrically to the impeller.

AC centrifugal fans

tin-plated

Air performance measured as per: ISO 5801,


Accessories

Installation category A, with ebm-papst inlet nozzle


without protection against accidental contact.
Noise: Total sound power level LWA ISO 103002
measuredon half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance
to fan axis.
The acoustic values given are only valid for the
max. 8 deep

described measurement set-up and may vary


depending on the installation situation.
In case of any deviation to the standard setup, the
values have to be checked and reviewed once
installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Inlet nozzles
2016-01

from p. 252
117
max. 255 m /h 3
DC centrifugal fans
Ø 165 x 51 mm

– Material: Impeller: GRP1) – Possible special versions:


– Direction of air flow: Axial: Intake (See chapter DC fans - specials)
Centrifugal: Exhaust - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Backwards-curved impeller - PWM control input
– Mass: 590 g - Analog control input
- Humidity protection
- Salt fog protection
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RER 160 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RER 160-28/12 N 255 150 12 7...14 6,4 19,0 3 000 -20...+70 75 000 / 37 500 127 500 ➀
RER 160-28/14 N 255 150 24 12...28 6,4 19,0 3 000 -20...+70 75 000 / 37 500 127 500 ➀
RER 160-28/18 N 255 150 48 28...60 6,4 19,0 3 000 -20...+70 75 000 / 37 500 127 500 ➀
Subject to alterations

The air flow and noise level of the centrifugal fans without
external housing depend on their individual installation
conditions. The stated air flow and noise level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate 260 x 260 mm.
Cover plate 260 x 260 mm, with an air inlet opening Ø 100 mm,
arranged concentrically to the impeller.

tin-plated

Air performance measured as per: ISO 5801,


Installation category A, with ebm-papst inlet nozzle without
protection against accidental contact.
Noise: Total sound power level LWA ISO 103002
max. 8 deep

measuredon half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values given are only valid for the described measure-
ment set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have to
be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Inlet nozzles
2016-01

118 from p. 252


Information
max. 370 m /h 3
DC centrifugal fans
Ø 165 x 51 mm

– Material: Impeller: GRP1) – Possible special versions:


– Direction of air flow: Axial: Intake (See chapter DC fans - specials)
Centrifugal: Exhaust - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Alarm with limit speed
TR 64 - External temperature sensor
– Highlights: Highly efficient and smoothly - Internal temperature sensor
running 3-phase fan drive - PWM control input
Backwards-curved impeller - Analog control input
– Mass: 590 g - Humidity protection
- Degree of protection: IP 54

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RER 160 NTD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RER 160-28/14 NTD… 360 211 24 16...28 7,4 51 4 200 -20...+60 55 000 / 27 500 92 500 ➁
RER 160-28/18 NTD… 360 211 48 38...57 7,4 48 4 200 -20...+70 55 000 / 27 500 92 500 ➀
Subject to alterations
Model RER 160-28/18 NTD... is available in customer-specific, custom-developed variant only.
The data specified here are technically feasible benchmark values. The fans can be specially adapted to your application

ACmaxx / EC fans
with signal outputs and control inputs.
* The specific service life is valid when an external capacitor is wired between the plus and minus wires.
Please note the wiring suggestion.

The air flow and noise level of the centrifugal fans without
external housing depend on their individual installation
conditions. The stated air flow and noise level were recorded
under the following measurement parameters:

AC axial fans
Centrifugal fan mounted on a foundation plate 260 x 260 mm.
Cover plate 260 x 260 mm, with an air inlet opening Ø 100 mm,
arranged concentrically to the impeller.

AC centrifugal fans

tin-plated
Accessories

Air performance measured as per: ISO 5801,


Installation category A, with ebm-papst inlet nozzle without
protection against accidental contact.
Noise: Total sound power level LWA ISO 103002
max. 8 deep

measuredon half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values given are only valid for the described measure-
ment set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have to
be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Inlet nozzles
2016-01

from p. 252
119
max. 800 m /h 3
DC centrifugal fans
Ø 175 x 55 mm

– Material: Impeller: Galvanised sheet steel – Possible special versions:


– Direction of air flow: Axial: Intake, Centrifugal: Exhaust (See chapter DC fans - specials)
– Direction of rotation: Clockwise, seen on rotor - Speed signal
– Connection: Via single wires AWG 18, 20 or - Go- / NoGo-alarm
AWG 22, TR 64, speed signal - Alarm with limit speed
and control input AWG 22 - External temperature sensor
– Highlights: Highly efficient and smoothly - Internal temperature sensor
running 3-phase fan drive - PWM control input
Backwards-curved impeller - Analog control input
– Mass: 930 g - Multi-option control input
- Humidity protection
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series REF 175 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

REF 175-30/18/2 TDP 800 470 48 36 ... 72 8,3 144 4 400 -20...+60 65 000 / 37 500 110 000 ➀
Subject to alterations
Speed control range from 800 rpm up to maximum speed. Standstill at 0 % PWM.
Type P: maximum speed if control wire is interrupted.

The air flow and noise level of the centrifugal fans without
external housing depend on their individual installation
conditions. The stated air flow and noise level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate 180 x 180 mm.
Cover plate 180 x 180 mm, with an air inlet opening Ø 125,5 mm,
arranged concentrically to the impeller.

tin-plated

Air performance measured as per: ISO 5801,


Installation category A, with ebm-papst inlet nozzle without
protection against accidental contact.
Noise: Total sound power level LWA ISO 103002
measuredon half-sphere of 2 m;
max. 8 deep

Sound pressure level LpA measured at 1 m distance to fan axis.


The acoustic values given are only valid for the described
measurement set-up and may vary depending on the
installation situation.
In case of any deviation to the standard setup, the values
have to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Inlet nozzles
2016-01

120 from p. 252


Information
max. 980 m /h 3
DC centrifugal fans
Ø 175 x 69 mm

– Material: Impeller: GRP1) – Possible special versions:


– Direction of air flow: Axial: Intake (See chapter DC fans - specials)
Centrifugal: Exhaust - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 18, 20 or - Alarm with limit speed
AWG 22, TR 64, speed signal - External temperature sensor
and control input AWG 22 - Internal temperature sensor
– Highlights: Highly efficient and smoothly - PWM control input
running 3-phase fan drive - Analog control input
Backwards-curved impeller - Multi-option control input
– Mass: 775 g - Humidity protection

DC centrifugal fans
- Salt fog protection
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RER 175 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RER 175-42/14/2 TDMLP 600 353 24 16...30 7,3 48 3 400 -20...+65 72 500 / 40 000 122 500 ➀
RER 175-42/14/2 TDMP 865 509 24 16...36 8,2 110 4 800 -20...+65 70 000 / 40 000 117 500 ➁
RER 175-42/18/2 TDMLP 600 353 48 36...57 7,3 46 3 400 -20...+65 72 500 / 40 000 122 500 ➀
RER 175-42/18/2 TDMP* 865 509 48 36...72 8,2 110 4 800 -20...+65 70 000 / 40 000 117 500 ➁

ACmaxx / EC fans
RER 175-42/18/2 TDP 980 577 48 36...72 8,5 166 5 400 -20...+65 60 000 / 32 500 102 500 ➂
* On request
Subject to alterations
Speed control range from 800 rpm up to maximum speed. Standstill at 0 % PWM.
Type P: maximum speed if control wire is interrupted.

The air flow and noise level of the centrifugal fans without
external housing depend on their individual installation
conditions. The stated air flow and noise level were recorded

AC axial fans
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate 180 x 180 mm.
Cover plate 180 x 180 mm, with an air inlet opening Ø 125,5 mm,
arranged concentrically to the impeller.

AC centrifugal fans
6 +1

tin-plated
425 +10

Accessories
ø175 +0,5
ø58 + 0,1
ø 72 +0,3

Air performance measured as per: ISO 5801,


Installation category A, with ebm-papst inlet nozzle without
protection against accidental contact.
Noise: Total sound power level LWA ISO 103002
max. 8 deep
M4 (4x)

measuredon half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values given are only valid for the described measurement
set-up and may vary depending on the installation situation.
In case of any deviation to the standard setup, the values have to be 6,8+ 0,8
checked and reviewed once installed or fitted. 42
Representatives

For detailed information see


69 ±1
http://www.ebmpapst.com/general conditions

Inlet nozzles
2016-01

from p. 252
121
max. 970 m /h 3
DC centrifugal fans – RadiCal
Ø 190 x 69 mm

– Material: Impeller: GRP1) – Possible special versions:


– Direction of air flow: Axial: Intake, Centrifugal: Exhaust (See chapter DC fans - specials)
– Direction of rotation: Clockwise, seen on rotor - Speed signal
– Connection: Via single wires AWG 18, 20 or - Go- / NoGo-alarm
AWG 22, TR 64, speed signal - Alarm with limit speed
and control input AWG 22 - External temperature sensor
– Highlights: Highly efficient and smoothly - Internal temperature sensor
running 3-phase fan drive - PWM control input
Backwards-curved RadiCal - Analog control input
impeller - Multi-option control input
– Mass: 870 g - Humidity protection
- Salt fog protection
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RER 190 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RER 190-39/14/2 TDMLO 650 382 24 16...30 7,6 58 3 000 -20...+60 55 000 / 35 000 92 500 ➀
RER 190-39/14/2 TDMO 860 506 24 16...36 7,9 110 3 900 -20...+65 52 500 / 30 000 87 500 ➁
RER 190-39/18/2 TDMLO* 650 382 48 36...57 7,6 56 3 000 -20...+65 55 000 / 30 000 92 500 ➀
RER 190-39/18/2 TDMO* 860 506 48 36...72 7,9 105 3 900 -20...+65 52 500 / 30 000 87 500 ➁
RER 190-39/18/2 TDO 970 571 48 36...72 8,3 148 4 400 -20...+65 40 000 / 22 500 67 500 ➂
*On request
Speed control range from 800 rpm up to maximum speed. Standstill at 0 % PWM / 0 V,
Subject to alterations
Type O: Standstill if control wire is interrupted. see p. 180.

The air flow and noise level of the centrifugal fans without
external housing depend on their individual installation
conditions. The stated air flow and noise level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate 195 x 195 mm.
Cover plate 195 x 195 mm, with an air inlet opening Ø 125,5 mm,
arranged concentrically to the impeller.
6 +1

tin-plated
425 +10

Air performance measured as per: ISO 5801,


Installation category A, with ebm-papst inlet nozzle
190 + 0,3
72 +0,3
58 + 0,1

without protection against accidental contact.


Noise: Total sound power level LWA ISO 103002
measuredon half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance
max. 8 deep

to fan axis.
M4 (4x)

The acoustic values given are only valid for the


described measurement set-up and may vary
depending on the installation situation.
In case of any deviation to the standard setup, the 39
values have to be checked and reviewed once instal- 6,5 +1
led or fitted. 69 +1
For detailed information see
http://www.ebmpapst.com/general conditions

Inlet nozzles
2016-01

122 from p. 252


123
2016-01

Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans DC axial fans Information
max. 930 m /h 3
DC centrifugal fans – RadiCal
Ø 190 mm

– Material: Impeller: Plastic PA


Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 44, depending on installation and position
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound power level

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) °C

R3G 190 M3G 074-CF A 24 16-28 880 4 570 180 7,50 76 -25..+60 p. 262 / J5)

R3G 190 M3G 074-CF B 48 36-57 930 4 800 192 4,00 76 -25..+60 p. 262 / J5)
Subject to alterations

n Ped I L WA
Curves: rpm W A dB(A)
B
A 1 4 570 180 7,50 84
A 2 4 525 188 7,83 79
A 3 4 435 199 8,34 77
A
A 4 4 520 191 7,96 81
B 1 4 800 192 4,00 84
B 2 4 690 212 4,41 80
B 3 4 640 221 4,60 79
B 4 4 740 205 4,28 81

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

124
Information
– Technical features: See electrical connections p. 262
– Cable exit: Variabel
– Product conforming

DC axial fans
to standards: EN 60950-1
– Approvals: EAC

DC centrifugal fans
centrifugal fans

DC fans - specials
Mass

Centrifugal fans kg Inlet nozzle

R3G 190-RN38 -01 1,9 09576-2-4013

R3G 190-RN99 -02 1,9 09576-2-4013

ACmaxx / EC fans
Accessory part: Inlet nozzle 09576-2-4013
not included in the standard scope of
Depth of screw
delivery
max. 12 - 14 mm

AC axial fans
AC centrifugal fans
Accessories

Connecting line PVC AWG 16


4 x crimped core-end sleeves
Representatives

Inlet nozzles Electrical connections


2016-01

p. 254 p. 262
125
max. 1 210 m /h 3
DC centrifugal fans – RadiCal
Ø 220 mm

– Material: Impeller: Plastic PA


Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 44, depending on installation and position
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound power level

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) °C

R3G 220 M3G 074-CF A 24 16-28 1 200 3 460 157 6,50 73 -25...+60 p. 262 / J5)

R3G 220 M3G 074-CF B 48 36-57 1 215 3 510 160 3,40 73 -25...+60 p. 262 / J5)
Subject to alterations

n Ped I L WA
Curves: rpm W A dB(A)

B A 1 3 460 157 6,50 81


A 2 3 420 171 7,11 77
A 3 3 360 182 7,59 74
A
A 4 3 455 168 6,97 79
B 1 3 510 160 3,40 81
B 2 3 450 168 3,50 77
B 3 3 385 178 3,71 74
B 4 3 460 167 3,47 79

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

126
Information
– Technical features: See electrical connections p. 262
– Cable exit: Variabel
– Product conforming

DC axial fans
to standards: EN 60950-1
– Approvals: EAC

DC centrifugal fans
centrifugal fans

DC fans - specials
Mass

Centrifugal fans kg Inlet nozzle

R3G 220-RN12 -01 1,9 09609-2-4013

R3G 220-RNB6 -02 1,9 09609-2-4013

ACmaxx / EC fans
Accessory part: Inlet nozzle 09609-2-4013
not included in the standard scope of
delivery
Depth of screw
max. 12 - 14 mm

AC axial fans
AC centrifugal fans
Accessories

Connecting line PVC AWG 16


4 x crimped core-end sleeves
Representatives

Inlet nozzles Electrical connections


2016-01

p. 253 p. 262
127
max. 1 250 m /h 3
DC centrifugal fans – RadiCal
Ø 221 x 71 mm

– Material: Impeller: GRP1) – Possible special versions:


– Direction of air flow: Axial: Intake (See chapter DC fans - specials)
Centrifugal: Exhaust - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 18, 20 or - Alarm with limit speed
AWG 22, TR 64, speed signal - External temperature sensor
and control input AWG 22 - Internal temperature sensor
– Highlights: Highly efficient and smoothly - PWM control input
running 3-phase fan drive - Analog control input
Backwards-curved impeller - Multi-option control input
– Mass: 940 g - Humidity protection
- Salt fog protection
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RER 220 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RER 220-43/14/2 TDMO* 1 063 625 24 16...36 tbd 110 3 000 -20...+55 65 000 / 45 000 110 000 ➀
RER 220-43/18/2 TDMO 1 063 625 48 36...72 tbd 110 3 000 -20...+55 65 000 / 45 000 110 000 ➀
RER 220-43/18/2 TDO 1 250 735 48 36...72 tbd 160 3 500 -20...+55 60 000 / 42 500 102 500 ➁
Subject to alterations
Speed control range from 800 rpm up to maximum speed. Standstill at 0 % PWM / 0 V,
* On request
Type O: Standstill if control wire is interrupted. see p. 180.

The air flow and noise level of the centrifugal fans without
external housing depend on their individual installation
conditions. The stated air flow and noise level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate 230 x 230 mm.
Cover plate 230 x 230 mm, with an air inlet opening Ø 155 mm,
arranged concentrically to the impeller.

tin-plated

Air performance measured as per: ISO 5801,


Installation category A, with ebm-papst inlet nozzle without
protection against accidental contact.
Noise: Total sound power level LWA ISO 103002
measuredon half-sphere of 2 m;
max. 8 deep

Sound pressure level LpA measured at 1 m distance to fan axis.


The acoustic values given are only valid for the described
measurement set-up and may vary depending on the
installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions

Inlet nozzles
2016-01

128 from p. 253


Information
max. 1 600 m /h 3
DC centrifugal fans
Ø 225 x 99 mm

– Material: Impeller: GRP1) – Possible special versions:


– Direction of air flow: Axial: Intake (See chapter DC fans - specials)
Centrifugal: Exhaust - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 18, 20 or - Alarm with limit speed
AWG 22, TR 64, speed signal - External temperature sensor
and control input AWG 22 - Internal temperature sensor
– Highlights: Highly efficient and smoothly - PWM control input
running 3-phase fan drive - Analog control input
Backwards-curved impeller - Multi-option control input
– Mass: 1030 g - Humidity protection

DC centrifugal fans
- Salt fog protection
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series RER 225 TD

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VDC VDC Bel(A) / Watts rpm °C Hours Hours

RER 225-63/18/2 TDMLO 1 190 700 48 36...72 7,2 77 2 500 -20...+55 70 000 / 50 000 122 500 ➀
RER 225-63/18/2 TDMO 1 340 789 48 36...72 7,8 108 2 800 -20...+55 55 000 / 40 000 92 500 ➁
RER 225-63/18/2 TDO 1 600 941 48 36...72 8,1 163 3 300 -20...+55 52 500 / 37 500 87 500 ➂
Subject to alterations

ACmaxx / EC fans
Speed control range from 800 rpm up to maximum speed. Standstill at 0 % PWM / 0 V,
Type O: Standstill if control wire is interrupted. see p. 180.

The air flow and noise level of the centrifugal fans without
external housing depend on their individual installation
conditions. The stated air flow and noise level were recorded
under the following measurement parameters:

AC axial fans
Centrifugal fan mounted on a foundation plate 230 x 230 mm.
Cover plate 230 x 230 mm, with an air inlet opening Ø 146 mm,
arranged concentrically to the impeller.

AC centrifugal fans

tin-plated

Air performance measured as per: ISO 5801,


Accessories

Installation category A, with ebm-papst inlet nozzle


without protection against accidental contact.
Noise: Total sound power level LWA ISO 103002
measuredon half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance
to fan axis.
max. 8 deep

The acoustic values given are only valid for the


described measurement set-up and may vary
depending on the installation situation.
In case of any deviation to the standard setup, the
values have to be checked and reviewed once
installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Inlet nozzles
2016-01

from p. 252
129
max. 1 400 m /h 3
DC centrifugal fans – RadiCal
Ø 225 mm

– Material: Impeller: Plastic PA


Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 44, depending on installation and position
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound power level

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) °C

R3G 225 M3G 074-CF A 24 16-28 1 300 3 270 205 8,50 75 -25...+60 p. 262 / J5)

R3G 225 M3G 074-CF B 48 36-57 1 340 3 400 230 4,80 73 -25...+60 p. 262 / J5)
Subject to alterations

n Ped I L WA
Curves: rpm W A dB(A)

A 1 3 270 205 8,50 81


B A 2 3 200 208 8,66 78
A 3 3 185 213 8,88 74
A 4 3 260 194 8,02 77
A
B 1 3 400 230 4,80 83
B 2 3 440 257 5,35 80
B 3 3 435 260 5,43 76
B 4 3 500 239 4,97 78

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

130
Information
– Technical features: See electrical connections p. 262
– Cable exit: Variabel
– Product conforming

DC axial fans
to standards: EN 60950-1
– Approvals: EAC

DC centrifugal fans
centrifugal fans

DC fans - specials
Mass

Centrifugal fans kg Inlet nozzle

R3G 225-RN28 -01 2,1 96358-2-4013

R3G 225-RN18 -02 2,1 96358-2-4013

ACmaxx / EC fans
Accessory part: Inlet nozzle 96358-2-4013
not included in the standard scope of
Depth of screw
delivery
max. 12 - 14 mm

AC axial fans
AC centrifugal fans
Accessories

Connecting line PVC AWG 16


4 x crimped core-end sleeves
Representatives

Inlet nozzles Electrical connections


2016-01

p. 254 p. 262
131
max. 1 650 m /h 3
DC centrifugal fans – RadiCal
Ø 250 mm

– Material: Impeller: Plastic PA


Rotor: Coated in black
– Number of blades: 7
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 44, depending on installation and position
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound power level

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) °C

R3G 250 M3G 074-CF A 24 16-28 1 505 2 850 175 7,20 73 -25...+60 p. 262 / J5)

R3G 250 M3G 074-CF B 48 36-57 1 640 3 100 230 4,80 73 -25...+60 p. 262 / J5)
Subject to alterations

n Ped I L WA
Curves: rpm W A dB(A)
B
A A 1 2 850 175 7,20 81
A 2 3 075 260 10,80 77
A 3 3 035 276 11,45 75
A 4 3 095 256 10,66 75
B 1 3 100 230 4,75 81
B 2 3 065 249 5,20 77
B 3 3 025 266 5,55 75
B 4 3 090 244 4,80 78

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

132
Information
– Technical features: See electrical connections p. 262
– Cable exit: Variabel
– Product conforming

DC axial fans
to standards: EN 60950-1
– Approvals: EAC

DC centrifugal fans
centrifugal fans

DC fans - specials
Mass

Centrifugal fans kg Inlet nozzle

R3G 250-RN46 -01 2,1 96359-2-4013

R3G 250-RNB5 -02 2,1 96359-2-4013

ACmaxx / EC fans
Accessory part: Inlet nozzle 96359-2-4013
not included in the standard scope of
delivery Depth of screw
max. 12 - 14 mm

AC axial fans
AC centrifugal fans
Accessories

Connecting line PVC AWG 16


4 x crimped core-end sleeves
Representatives

Inlet nozzles Electrical connections


2016-01

p. 254 p. 262
133
max. 2 210 m /h 3
DC centrifugal fans – RadiCal
Ø 280 mm

– Material: Impeller: Plastic PP


Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 44, depending on installation and position
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound power level

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) °C

R3G 280 M3G 074-CF A 24 16-28 2 190 1 900 142 5,90 67 -25...+60 p. 262 / J5)

R3G 280 M3G 074-CF B 48 36-57 2 160 1 910 140 2,90 67 -25...+60 p. 262 / J5)
Subject to alterations

n Ped I L WA
Curves: rpm W A dB(A)
A
A 1 1 900 142 5,90 74
B A 2 1 870 162 6,76 67
A 3 1 840 173 7,21 64
A 4 1 905 153 6,36 68
B 1 1 910 140 2,90 74
B 2 1 845 158 3,30 67
B 3 1 830 163 3,40 64
B 4 1 900 141 2,93 68

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

134
Information
– Technical features: See electrical connections p. 262
– Cable exit: Variabel
– Product conforming

DC axial fans
to standards: EN 60950-1
– Approvals: EAC

DC centrifugal fans
centrifugal fans

DC fans - specials
Mass

Centrifugal fans kg Inlet nozzle

R3G 280-RN30 -01 2,4 28000-2-4013

R3G 280-RNB1 -02 2,4 28000-2-4013

ACmaxx / EC fans
Accessory part: Inlet nozzle 28000-2-4013
not included in the standard scope of
delivery Depth of screw
max. 12 - 14 mm

AC axial fans
AC centrifugal fans
Accessories

Connecting line PVC AWG 16


4 x crimped core-end sleeves
Representatives

Inlet nozzles Electrical connections


2016-01

p. 254 p. 262
135
max. 2 420 m /h 3
DC centrifugal fans – RadiCal
Ø 310 mm

– Material: Impeller: Plastic PP


Rotor: Coated in black
– Number of blades: 6
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 44, depending on installation and position
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound power level

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h RPM W A dB(A) °C

R3G 310 M3G 074-CF A 24 16-28 2 310 1 580 108 4,50 64 -25...+60 p. 262 / J5)

R3G 310 M3G 074-CF B 48 36-57 2 380 1 620 123 2,60 64 -25...+60 p. 262 / J5)
Subject to alterations

n Ped I L WA
Curves: rpm W A dB(A)
B
A 1 1 580 108 4,50 70
A 2 1 540 145 6,03 67
A 3 1 520 152 6,34 63
A A 4 1 550 143 5,95 65
B 1 1 620 123 2,60 70
B 2 1 570 147 3,07 66
B 3 1 545 156 3,26 63
B 4 1 580 144 3,01 66

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst inlet nozzle without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

136
Information
– Technical features: See electrical connections p. 262
– Cable exit: Variabel
– Product conforming

DC axial fans
to standards: EN 60950-1
– Approvals: EAC

DC centrifugal fans
centrifugal fans

DC fans - specials
Mass

Centrifugal fans kg Inlet nozzle

R3G 310-RN99 -01 2,8 31000-2-4013

R3G 310-RN98 -02 2,8 31000-2-4013

ACmaxx / EC fans
Accessory part: Inlet nozzle 31000-2-4013
not included in the standard scope of Depth of screw
delivery max. 12 - 14 mm

AC axial fans
AC centrifugal fans
Accessories

Connecting line PVC AWG 16


4 x crimped core-end sleeves
Representatives

Inlet nozzles Electrical connections


2016-01

p. 254 p. 262
137
max. 155 m /h 3
DC cross-flow blowers
201...413 x 50 x 48 mm

– Material: Housing: Aluminium – Possible special versions:


Housing side parts: Plastic (See chapter DC fans - specials)
Impeller: Aluminium - Speed signal
– Direction of air flow: See photo - Humidity protection
– Connection: Via single wires AWG 24,
TR 64
– Highlights: Motor with ball bearing system
Impeller retaining plate with
sleeve bearing
– Mass: 235 / 290 / 380 / 415 g

Sintec sleeve bearings

Life expectancy L10IPC


Service life L10 (40 °C)

Service life L10 (Tmax)


Series QG 030

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VDC VDC db(A) Bel(A) / Watts °C Hours Hours

QG 030-148/12 75 44 12 8...14 49 5,7 / 6,2 -20...+60 30 000 / 20 000 50 000 ➀


QG 030-198/12 100 59 12 8...14 51 5,8 / 8,0 -20...+60 30 000 / 20 000 50 000 ➁
QG 030-303/12 140 82 12 8...14 51 5,8 / 8,7 -20...+60 30 000 / 20 000 50 000 ➂
QG 030-353/12 155 91 12 8...14 51 5,9 / 9,6 -20...+60 30 000 / 20 000 50 000 ➃
QG 030-148/14 75 44 24 16...28 49 5,7 / 6,2 -20...+60 30 000 / 20 000 50 000 ➀
QG 030-198/14 100 59 24 16...28 51 5,8 / 8,0 -20...+60 30 000 / 20 000 50 000 ➁
QG 030-303/14 140 82 24 16...28 51 5,8 / 8,7 -20...+60 30 000 / 20 000 50 000 ➂
QG 030-353/14 155 91 24 16...28 51 5,9 / 9,6 -20...+60 30 000 / 20 000 50 000 ➃
Subject to alterations

The values for service life were recorded with the


fan installed horizontally.
Type Dimension: L L1 Mass

QG 030-148/ .. 203,4 +1,5 148 235 g


QG 030-198/ .. 260,4 +1,5 198 290 g
+1,5
QG 030-303/ .. 365,4 303 380 g
QG 030-353/ .. 415,4 +1,5 353 415 g

Cross-flow blowers are only suitable for operation


with high rate and low back pressure.

Air performance measured as per: ISO 5801,


Installation category A, without accidental
contact.
Noise: Total sound power level LWA ISO
103002 measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m
distance to fan axis.
The acoustic values are only valid for the
described measurement set-up and may vary
depending on the installation situation.
In case of any deviation to the standard
setup, the values have to be checked and
reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions Cut-out for square nut M3 DIN 562, flat (6x)
2016-01

138
139
2016-01

Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans DC axial fans Information
max. 95 m /h 3
DC centrifugal fans and blowers
Ø 85 mm

– Material: Housing: Die-cast aluminium


Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound pressure level

Min. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C

*1G 085 M1G 045-BE A 24 16-28 95 2 850 14 0,64 57 0 -25...+60 p. 259 / G)

*1G 085 M1G 045-BE A 48 36-57 95 2 850 14 0,32 57 0 -25...+60 p. 259 / G)


Subject to alterations

n Ped LpA htL


Curves: rpm W dB(A) %

UN = nominal A 1’ 3 180 19 59 —
voltage A 2’ 3 300 16 57 28
(24 V /48 V) A 3’ 3 500 15 57 32
A 4’ 3 800 12 57 37
UR = overvoltage A 1 2 850 14 57 —
(28 V / 57 V) A 2 3 000 12 55 28
A 3 3 180 11 55 32
A 4 3 400 9 54 37
A 5 1 890 5 46 —
A 6 1 970 4 44 25
A 7 2 070 4 44 30
A 8 2 170 3 42 33

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

140
Information
– Technical features: See electrical connections p. 259
– Cable exit: Axial
– Product conforming

DC axial fans
to standards: EN 60950-1
– Approvals: EAC

DC centrifugal fans
centrifugal blowers
centrifugal fans

DC fans - specials
Mass

Mass

Centrifugal blowers
Centrifugal fans kg with flange kg

R1G 085-AB05 -01 0,5 G1G 085-AB05 -01 0,8

R1G 085-AB07 -01 0,5 G1G 085-AB07 -01 0,8

ACmaxx / EC fans
Depth of screw
max. 4 mm

AC axial fans
AC centrifugal fans
Brass lead tips
Accessories
Representatives

Guard grilles Inlet nozzles Electrical connections


2016-01

p. 247 p. 253 p. 259


141
max. 95 m /h 3
DC centrifugal fans and blowers
Ø 97 mm

– Material: Housing: Hot-dip galvanised sheet steel


Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound pressure level

Min. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C

*1G 097 M1G 045-BE A 24 16-28 95 2 650 16 0,75 59 0 -25...+60 p. 259 / G)

*1G 097 M1G 045-BE A 48 36-57 95 2 650 16 0,38 59 0 -25...+60 p. 259 / G)


Subject to alterations

n Ped LpA htL


Curves: rpm W dB(A) %

UN = nominal A 1’ 2 920 22 62 —
voltage A 2’ 3 030 21 61 41
(24 V /48 V) A 3’ 3 300 17 59 48
A 4’ 3 700 13 58 48
UR = overvoltage A 1 2 650 16 59 —
(28 V / 57 V) A 2 2 730 15 58 41
A 3 2 960 13 56 48
A 4 3 290 10 55 48
A 5 1 615 4 45 —
A 6 1 650 4 45 38
A 7 1 745 4 43 46
A 8 1 880 3 42 47

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

142
Information
– Technical features: See electrical connections p. 259
– Cable exit: Axial
– Product conforming

DC axial fans
to standards: EN 60950-1
– Approvals: EAC

DC centrifugal fans
centrifugal blowers
centrifugal fans

DC fans - specials
Mass

Mass

Centrifugal blowers
Centrifugal fans kg with flange kg

R1G 097-AA05 -01 0,5 G1G 097-AA05 -01 0,8

R1G 097-AA07 -01 0,5 G1G 097-AA07 -01 0,8

ACmaxx / EC fans
Depth of screw
max. 4 mm

Brass lead tips AC axial fans


AC centrifugal fans
Accessories
Representatives

Guard grilles Inlet nozzles Electrical connections


2016-01

p. 242 p. 253 p. 259


143
max. 200 m /h 3
DC centrifugal fans and blowers
Ø 108 mm

– Material: Housing: Die-cast aluminium


Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound pressure level

Min. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C

*1G 108 M1G 055-BD A 24 16-28 200 3 000 42 2,00 65 0 -25...+60 p. 259 / G)

*1G 108 M1G 055-BD .A 48 36-57 200 3 000 42 1,00 65 0 -25...+60 p. 259 / G)
Subject to alterations

n Ped LpA htL


Curves: rpm W dB(A) %

UN = nominal A 1’ 3 230 55 67 —
voltage A 2’ 3 410 52 66 33
(24 V /48 V) A 3’ 3 800 43 65 41
A 4’ 4 100 35 64 33
UR = overvoltage A 1 3 000 42 65 —
(28 V / 57 V) A 2 3 140 40 64 33
A 3 3 420 32 63 41
A 4 3 690 26 63 33
A 5 2 300 20 61 —
A 6 2 380 17 58 33
A 7 2 550 14 55 41
A 8 2 720 11 55 33

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

144
Information
– Technical features: See electrical connections p. 259
– Cable exit: Axial
– Protection class: I

DC axial fans
– Product conforming
to standards: EN 60950-1
– Approvals: A (24 VDC) UL, CSA, A (48 VDC) CCC

DC centrifugal fans
centrifugal blowers
centrifugal fans

DC fans - specials
Mass

Mass

Centrifugal blowers
Centrifugal fans kg with flange kg

R1G 108-AB17 -02 0,7 G1G 108-AB17 -02 1,4

R1G 108-AB41 -02 0,7 G1G 108-AB41 -02 1,4

ACmaxx / EC fans
Depth of screw
max. 6 mm

Brass lead tips AC axial fans


AC centrifugal fans
Accessories
Representatives

Guard grilles Inlet nozzles Air filter Electrical connections


2016-01

p. 247 p. 253 p. 254 p. 259


145
max. 255 m /h 3
DC centrifugal fans and blowers
Ø 120 mm

– Material: Housing: Die-cast aluminium


Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound pressure level

Min. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C

*1G 120 M1G 055-BD A 24 16-28 255 2 200 40 1,90 62 0 -25...+60 p. 259 / G)

*1G 120 M1G 055-BD A 48 36-57 255 2 200 40 0,95 62 0 -25...+60 p. 259 / G)
Subject to alterations

n Ped LpA htL


Curves: rpm W dB(A) %

UN = nominal A 1’ 2 410 50 63 —
voltage A 2’ 2 620 47 62 58
(24 V /48 V) A 3’ 2 870 44 61 60
A 4’ 3 200 36 62 55
UR = overvoltage A 1 2 200 40 62 —
(28 V / 57 V) A 2 2 410 36 60 59
A 3 2 600 32 58 62
A 4 2 880 25 58 55
A 5 1 870 24 55 —
A 6 1 990 21 54 58
A 7 2 100 18 53 61
A 8 2 310 14 54 54

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

146
Information
– Technical features: See electrical connections p. 259
– Cable exit: Axial
– Protection class: I

DC axial fans
– Product conforming
to standards: EN 60950-1
– Approvals: A (24 VDC) UL, CSA, A (48 VDC) CCC

DC centrifugal fans
centrifugal blowers
centrifugal fans

DC fans - specials
Mass

Mass

Centrifugal blowers kg
Centrifugal fans kg with flange

R1G 120-AB67 -02 0,8 G1G 120-AB67 -02 1,6

R1G 120-AB71 -02 0,8 G1G 120-AB71 -02 1,6

ACmaxx / EC fans
Depth of screw
max. 6 mm

Brass lead tips AC axial fans


AC centrifugal fans
Accessories
Representatives

Guard grilles Inlet nozzles Air filter Electrical connections


2016-01

p. 247 p. 253 p. 254 p. 259


147
max. 225 m /h 3
DC centrifugal fans and blowers
Ø 133 mm

– Material: Housing: Die-cast aluminium


Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound pressure level

Min. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C

*1G 133 M1G 055-BD A 24 16-28 225 2 000 40 2,20 64 0 -25...+60 p. 259 / G)

*1G 133 M1G 055-BD A 48 36-57 225 2 000 40 1,10 64 0 -25...+60 p. 259 / G)
Subject to alterations

n Ped LpA htL


Curves: rpm W dB(A) %

UN = nominal A 1’ 2 170 57 66 —
voltage A 2’ 2 410 51 66 47
(24 V /48 V) A 3’ 2 750 44 64 49
A 4’ 3 200 36 66 32
UR = overvoltage A 1 2 000 45 64 —
(28 V / 57 V) A 2 2 230 40 64 49
A 3 2 540 35 62 51
A 4 2 920 27 63 33
A 5 1 750 28 60 —
A 6 1 910 24 59 50
A 7 2 120 20 58 53
A 8 2 370 15 59 35

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housig without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

148
Information
– Technical features: See electrical connections p. 259
– Cable exit: Lateral
– Protection class: I

DC axial fans
– Product conforming
to standards: EN 60950-1
– Approvals: A (24 VDC) UL, CSA, A (48 VDC) CCC

DC centrifugal fans
centrifugal blowers
centrifugal fans

DC fans - specials
Mass

Mass

Centrifugal blowers
Centrifugal fans kg with flange kg

R1G 133-AE19 -02 0,7 G1G 133-DE19 -02 1,3

R1G 133-AE03 -02 0,7 G1G 133-DE03 -02 1,3

ACmaxx / EC fans
Depth of screw
max. 6 mm

AC axial fans
Brass lead tips
AC centrifugal fans
Accessories
Representatives

Guard grilles Inlet nozzles Air filter Electrical connections


2016-01

p. 242 p. 253 p. 254 p. 259


149
max. 410 m /h 3
DC centrifugal fans and blowers
Ø 140 mm

– Material: Housing: Die-cast aluminium


Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound pressure level

Min. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C

*1G 140 M1G 055-BD A 24 16-28 400 1 750 54 2,50 63 0 -25...+60 p. 259 / G)

*1G 140 M1G 055-BD A 48 36-57 410 1 750 54 1,30 63 0 -25...+60 p. 259 / G)
Subject to alterations

n Ped LpA htL


Curves: rpm W dB(A) %

UN = nominal A 1’ 1 850 65 64 —
voltage A 2’ 2 020 61 61 50
(24 V /48 V) A 3’ 2 200 57 59 54
A 4’ 2 550 43 60 40
UR = overvoltage A 1 1 750 54 63 —
(28 V / 57 V) A 2 1 900 50 59 51
A 3 2 030 45 58 54
A 4 2 310 32 58 40
A 5 1 500 34 60 —
A 6 1 580 29 56 50
A 7 1 670 25 54 53
A 8 1 880 19 53 41

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

150
Information
– Technical features: See electrical connections p. 259
– Cable exit: Axial
– Protection class: I

DC axial fans
– Product conforming
to standards: EN 60950-1
– Approvals: A (48 VDC) CCC

DC centrifugal fans
centrifugal blowers
centrifugal fans

DC fans - specials
Mass

Mass

Centrifugal blowers
Centrifugal fans kg with flange kg

R1G 140-AV17 -02 1,0 G1G 140-AV17 -02 2,3

R1G 140-AV21 -02 1,0 G1G 140-AV21 -02 2,3

ACmaxx / EC fans
Depth of screw
max. 6 mm

Brass lead tips AC axial fans


AC centrifugal fans
Accessories
Representatives

Guard grilles Inlet nozzles Air filter Electrical connections


2016-01

p. 247 p. 253 p. 254 p. 259


151
max. 470 m /h 3
DC centrifugal fans and blowers
Ø 146 mm

– Material: Housing: Die-cast aluminium


Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound pressure level

Min. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C

*1G 146 M1G 074-BF A 24 16-28 470 2 200 100 5,00 68 0 -25...+60 p. 259 / G)

*1G 146 M1G 074-BF A 48 36-57 465 2 150 100 2,60 67 0 -25...+60 p. 259 / G)
Subject to alterations

n Ped LpA htL


Curves: rpm W dB(A) %

UN = nominal A 1’ 2 400 140 70 —


voltage A 2’ 2 650 130 67 45
(24 V /48 V) A 3’ 3 000 110 66 49
A 4’ 3 300 100 67 45
UR = overvoltage A 1 2 200 100 68 —
(28 V / 57 V) A 2 2 445 90 65 46
A 3 2 750 84 64 49
A 4 3 025 77 65 45
A 5 1 890 68 63 —
A 6 2 075 57 60 46
A 7 2 250 48 61 49
A 8 2 335 41 61 45
A 9 1 520 37 59 —
A 10 1 670 32 55 46
A 11 1 815 27 55 49
A 12 1 920 23 55 45

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

152
Information
– Technical features: See electrical connections p. 259
– Cable exit: Axial
– Protection class: I

DC axial fans
– Product conforming
to standards: EN 60950-1
– Approvals: UL, CSA, CCC (only centrifugal blowers)

DC centrifugal fans
centrifugal blowers
centrifugal fans

DC fans - specials
Mass

Mass

Centrifugal blowers
Centrifugal fans kg with flange kg

R1G 146-AA07 -52 1,4 G1G 146-BA07 -52 2,8

R1G 146-AA11 -52 1,4 G1G 146-BA11 -52 2,8

ACmaxx / EC fans
Depth of screw
max. 6 mm

Brass lead tips AC axial fans


AC centrifugal fans
Accessories
Representatives

Guard grilles Inlet nozzles Air filter Electrical connections


2016-01

p. 247 p. 253 p. 254 p. 259


153
max. 505 m /h 3
DC centrifugal fans and blowers
Ø 160 mm

– Material: Housing: Die-cast aluminium


Impeller: Hot-dip galvanised sheet steel
Rotor: Galvanised
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound pressure level

Min. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C

*1G 160 M1G 074-BF A 24 16-28 505 1 750 105 5,80 67 0 -25...+60 p. 259 / G)

*1G 160 M1G 074-BF A 48 36-57 505 1 750 105 2,90 67 0 -25...+60 p. 259 / G)
Subject to alterations

n Ped LpA htL


Curves: rpm W dB(A) %

UN = nominal A 1’ 1 890 134 68 —


voltage A 2’ 2 200 118 67 52
(24 V /48 V) A 3’ 2 500 110 67 57
A 4’ 2 900 102 69 52
UR = overvoltage A 1 1 750 105 67 —
(28 V / 57 V) A 2 2 030 95 66 52
A 3 2 270 90 65 57
A 4 2 550 81 67 44
A 5 1 580 72 62 —
A 6 1 810 66 62 52
A 7 2 000 58 62 57
A 8 2 200 48 63 54

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housig without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

154
Information
– Technical features: See electrical connections p. 259
– Cable exit: Axial
– Protection class: I

DC axial fans
– Product conforming
to standards: EN 60950-1
– Approvals: UL, CSA

DC centrifugal fans
centrifugal blowers
centrifugal fans

DC fans - specials
Mass

Mass

Centrifugal blowers
Centrifugal fans kg with flange kg

R1G 160-AH29 -52 1,4 G1G 160-BH29 -52 2,8

R1G 160-AH39 -52 1,4 G1G 160-BH39 -52 2,8

ACmaxx / EC fans
Depth of screw
max. 6 mm

Brass lead tips AC axial fans


AC centrifugal fans
Accessories
Representatives

Guard grilles Inlet nozzles Air filter Electrical connections


2016-01

p. 247 p. 253 p. 254 p. 259


155
max. 700 m /h 3
DC Centrifugal blowers
Ø 133 mm

– Material: Housing: Galvanised sheet steel


Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor anti-vibration mounted
on both sides
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound pressure level

Min. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C

D1G 133 M1G 074-BF A 24 16-28 700 1 780 105 5,60 62 50 -25...+60 p. 259 / G)

D1G 133 M1G 074-BF A 48 36-57 700 1 780 105 2,80 62 50 -25...+60 p. 259 / G)
Subject to alterations

n Ped LpA htL


Curves: rpm W dB(A) %

UN = nominal A 1’ — — — —
voltage A 2’ 2 050 121 63 49
(24 V /48 V) A 3’ 2 490 106 62 41
A 4’ 2 820 100 62 37
UR = overvoltage A 1 1 780 105 62 —
(28 V / 57 V) A 2 1 900 97 61 49
A 3 2 310 86 59 41
A 4 2 630 80 60 37
A 5 1 500 73 59 —
A 6 1 720 67 57 49
A 7 2 020 58 56 41
A 8 2 230 49 56 37

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

156
Information
– Technical features: See electrical connections p. 259
– Cable exit: Variabel
– Protection class: I

DC axial fans
– Product conforming
to standards: EN 60950-1
– Approvals: UL, CSA; A (48 VDC) auch CCC

DC centrifugal fans
centrifugal blowers

DC fans - specials
Mass

Centrifugal blowers kg
without flange

D1G 133-AB29 -52 3,3

D1G 133-AB39 -52 3,3

ACmaxx / EC fans
AC axial fans
AC centrifugal fans

Brass lead tips


Accessories
Representatives

Guard grilles Electrical connections


2016-01

p. 246 p. 259
157
max. 1 020 m /h 3
DC Centrifugal blowers
Ø 133 mm

– Material: Housing: Galvanised sheet steel


Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor anti-vibration mounted
on both sides
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound pressure level

Min. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C

D1G 133 M1G 074-BF A 24 16-28 1 020 1 580 118 6,00 64 0 -25...+60 p. 259 / G)

D1G 133 M1G 074-BF A 48 36-57 1 020 1 580 118 3,00 64 0 -25...+60 p. 259 / G)
Subject to alterations

n Ped LpA htL


Curves: rpm W dB(A) %

UN = nominal A 1’ 1 700 145 65 —


voltage A 2’ 1 930 133 62 38
(24 V /48 V) A 3’ 2 290 122 59 41
A 4’ 2 700 99 61 32
UR = overvoltage A 1 1 580 118 64 —
(28 V / 57 V) A 2 1 790 107 61 38
A 3 2 100 95 57 41
A 4 2 410 73 58 32
A 5 1 400 78 60 —
A 6 1 580 70 56 38
A 7 1 760 56 53 41
A 8 2 000 44 53 32

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

158
Information
– Technical features: See electrical connections p. 259
– EMV (24 VDC): Interference emission acc. to EN 55022, class B
Interference immunity acc. to EN 61000-6-2

DC axial fans
– Cable exit: Variabel
– Protection class: I
– Product conforming
to standards: EN 60950-1
– Approvals: UL, CSA

DC centrifugal fans
centrifugal blowers

DC fans - specials
Mass

Centrifugal blowers kg
without flange

D1G 133-DC13 -52 3,4

D1G 133-DC17 -52 3,4

ACmaxx / EC fans
AC axial fans
AC centrifugal fans
Accessories

Brass lead tips


Representatives

Guard grilles Electrical connections


2016-01

p. 246 p. 259
159
max. 1 000 m /h 3
DC Centrifugal blowers
Ø 146 mm

– Material: Housing: Galvanised sheet steel


Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor anti-vibration mounted
on both sides
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound pressure level

Min. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C

D1G 146 M1G 074-CF A 24 16-28 1 000 1 350 105 5,10 61 0 -25...+60 p. 259 / G)

D1G 146 M1G 074-CF A 48 36-57 1 000 1 350 105 2,60 61 0 -25...+60 p. 259 / G)
Subject to alterations

n Ped LpA htL


Curves: rpm W dB(A) %

UN = nominal A 1’ 1 460 129 63 —


voltage A 2’ 1 680 119 60 53
(24 V /48 V) A 3’ 1 890 111 58 61
A 4’ 2 240 95 59 55
UR = overvoltage A 1 1 350 105 61 —
(28 V / 57 V) A 2 1 570 95 58 53
A 3 1 750 88 56 61
A 4 2 010 70 57 55
A 5 1 210 70 56 —
A 6 1 360 60 54 53
A 7 1 460 53 52 61
A 8 1 670 42 51 55

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

160
Information
– Technical features: See electrical connections p. 259
– EMV (24 VDC): Interference emission acc. to EN 55022, class B
Interference immunity acc. to EN 61000-6-2

DC axial fans
– Cable exit: Variabel
– Protection class: I
– Product conforming
to standards: EN 60950-1
– Approvals: UL, CSA

DC centrifugal fans
centrifugal blowers

DC fans - specials
Mass

Centrifugal blowers kg
without flange

D1G 146-AA19 -52 3,5

D1G 146-AA33 -52 3,5

ACmaxx / EC fans
AC axial fans
AC centrifugal fans

Brass lead tips


Accessories
Representatives

Guard grilles Electrical connections


2016-01

p. 246 p. 259
161
max. 980 m /h 3
DC Centrifugal blowers
Ø 160 mm

– Material: Housing: Galvanised sheet steel


Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 42
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor anti-vibration mounted
on both sides
– Bearings: Maintenance-free ball bearings

Technical features and


electrical connections
Sound pressure level

Min. back-pressure

Perm. amb. temp.


Nominal voltage

Voltage range

Current draw
Speed / rpm

Input power
Air flow
Curve

Nominal data

Type Motor VDC VDC m3/h rpm W A dB(A) Pa °C

D1G 160 M1G 074-CF A 24 16-28 980 1 250 112 5,60 60 0 -25...+60 p. 259 / G)

D1G 160 M1G 074-CF A 48 36-57 980 1 250 112 2,90 60 0 -25...+60 p. 259 / G)
Subject to alterations

n Ped LpA htL


Curves: rpm W dB(A) %

UN = nominal A 1’ 1 330 142 63 —


voltage A 2’ 1 520 128 61 64
(24 V /48 V) A 3’ 1 790 115 59 66
A 4’ 2 090 105 60 60
UR = overvoltage A 1 1 250 112 60 —
(28 V / 57 V) A 2 1 420 102 59 64
A 3 1 660 92 58 66
A 4 1 900 80 58 60
A 5 1 100 75 58 —
A 6 1 250 69 56 64
A 7 1 420 58 54 66
A 8 1 580 47 53 60

Air performance measured as per: ISO 5801, Installation category A, with ebm-papst scroll housing without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

162
Information
– Technical features: See electrical connections p. 259
– Cable exit: Variabel
– Protection class: I

DC axial fans
– Product conforming
to standards: EN 60950-1
– Approvals: UL, CSA

DC centrifugal fans
centrifugal blowers

DC fans - specials
Mass

Centrifugal blowers kg
without flange

D1G 160-DA19 -52 3,6

D1G 160-DA33 -52 3,6

ACmaxx / EC fans
AC axial fans
Brass lead tips
AC centrifugal fans
Accessories
Representatives

Guard grilles Electrical connections


2016-01

p. 246 p. 259
163
2016-01

164
Information
DC fans - specials

DC axial fans
Speed signal 168
Alarm signal 172
Vario-Pro / Speed setting / Control input 177

DC centrifugal fans
Protection against ambient influences,
Degree of protection IP 54 / IP 68 181

DC fans - specials
ACmaxx / EC fans
AC axial fans
AC centrifugal fans
Accessories
Representatives
2016-01

165
DC fans - specials

Technical information

Cooling capacity and efficiency 1. Speed adjustment via temperature sensor


Greater power density, increasing miniaturisation and extreme electronic ebm-papst answers with a complete range of DC fans with temperature-
component density are posing increased demands on the cooling capacity controlled speed adjustment via a temperature sensor, available in a
and efficiency of fans. The intelligent and space-saving integration of the variety of standard dimensions.
fan in the device configuration is therefore of major importance:
Installation is very simple. The control electronics receive thermal
• Tailor-made cooling adapted to the situation as and when required. information for the speed adjustment continuously and without losses,
either externally via a freely designed and positionable strand, or
• Programmable cooling by defining speed profiles.
internally directly in the fan hub in the air flow. A range of temperature
• Transparency of function thanks to complete, interactive monitoring in sensors can be found on page 178.
all operating conditions.

2. DC fans with separate control input


Standard fans in electronics cooling have proven themselves millions of Open or closed-loop speed control is also possible with DC fans that have
times. a separate control input. A variation in speed can thus be implemented via
a control voltage or a pulse-width modulated signal. These possibilities
With a constant speed and a correspondingly high noise level, they conti-
are used primarily in devices that have appropriate standard interfaces
nuously provide the air flow needed for extreme cases. These extreme
and thus require a load-dependent variation of the fans.
situations, however, occur extremely rarely, if at all, during the operating
period. An intelligent fan is needed, which adapts automatically to the
currently required level of cooling.

ebm-papst provides intelligent cooling concepts which are optimally


adapted to requirements. For example:
2016-01

166
Information
DC fans - specials

DC axial fans
DC centrifugal fans
Technical information

DC fans - specials
3. Speed signal 6. Vario-Pro fans
DC fans with speed signal. This high-end fan concept by ebmpapst with programmed intelligence
The integrated „electronic tachometer“ continuously provides an actual and customer-specific integrated functions makes your electronics
speed signal for external evaluation. The user is informed at all times of cooling even more versatile and competitive. Vario-Pro ensures a fresh
the current fan speed via an extremely simple signal evaluation on the economic breeze for all demanding cooling tasks – e.g. where greater
customer side. The speed signal is via a separate lead. reliability, more flexibility and intelligent function features such as alarm

ACmaxx / EC fans
function, speed control etc. are required.
4. Alarm signal
For applications which require monitored fan operation with alarm The successful concept of Vario-Pro is: Tailor-made software instead of
signal, ebm-papst has numerous alarm signal versions, either a static, fixed hardware, because programmed software modules for motor control
pre-processed or interface-compatible high or low continuous signal and application intelligence are responsible for the work that analog com-
depending on the type of fan. ponents were responsible for in the past. This central control unit of the
Vario-Pro comprises a microcontroller and an EEPROM, on which all char-
5. Turbo drives acteristics are stored.
Fans with three-phase EC drives and microprocessor-controlled motor

AC axial fans
electronics. These three-phase motors whose torque is virtually non- 7. Protection against environmental influences
reliant on the rotor position are used for extremely high running smooth- Some applications place particular demands on the fans resistance to
ness. The speed of these fans can be controlled over a very wide range ambient influences, such as dust, moisture, water and salt. ebm-papst
with PWM, analog voltage or temperature. Optionally, the fans can be offer solutions for adapting fans to these ambient conditions.
supplied with reversible direction of rotation and active brake operation.

AC centrifugal fans
Accessories
Representatives
2016-01

167
Speed signal /2

– Speed-proportional square-wave signal for external speed monitoring of fan motor


– 2, 3 or 6 pulses per revolution
– Open collector signal output
– Extremely wide operating voltage range
– Easy adaptation to user interface
– Connection via separate lead
– The sensor signal also serves as a major comparison variable for setting and
maintaining the setpoint speed for interactive or controlled cooling with one or
several interconnected fans.

Pulses per revolution


Perm. sink current
Condition: Isource

voltage UBS max.


Sensor operating

Fan description
Condition: Isink
Speed signal

Speed signal
Electrical connection

Basic type
Isink max.
US High
US Low
Signal data

Type VDC mA VDC mA VDC mA Page


250 £ 0,4 2 £ 30 0 30 2 2 31
400 F £ 0,4 1 £ 30 0 30 2 2 32
400 £ 0,4 1 £ 30 0 30 2 2 33
420 J £ 0,4 2 £ 15 0 15 4 2 34
All voltages measured to ground. 500 F £ 0,4 1 £ 30 0 30 2 2 35
External load resistor Ra / US / UBS required. 600 F £ 0,4 1 £ 30 0 30 2 2 36
620 £ 0,4 2 £ 30 0 30 4 2 37
630 U £ 0,4 2 £ 30 0 30 4 2 38
600 N £ 0,4 2 £ 28 0 28 4 2 39
600 J £ 0,4 2 £ 30 0 30 4 2 41
700 F £ 0,4 2 £ 30 0 30 4 2 42
8450 £ 0,4 2 £ 28 0 28 4 2 43
8400 N £ 0,4 2 £ 28 0 28 4 2 44
8400 N VARIOFAN £ 0,4 2 £ 30 0 30 4 2 45
8300 £ 0,4 2 £ 30 0 30 4 2 46
8200 J £ 0,4 2 £ 30 0 30 4 2 47
3400 N £ 0,4 2 £ 28 0 28 4 2 48
3400 N VARIOFAN £ 0,4 2 £ 30 0 30 4 2 49
3300 N £ 0,4 2 £ 30 0 30 4 2 50
3212 J / 3214 J £ 0,4 2 £ 30 0 30 4 2 51
3218 J £ 0,4 2 £ 60 0 60 4 2 51
3250 J £ 0,4 2 £ 60 0 60 4 3 52
4412 F / 4414 F £ 0,4 2 £ 30 0 30 4 2 53
4418 F £ 0,4 2 £ 60 0 60 4 2 53
4400 FN £ 0,4 2 £ 30 0 30 4 2 55
4312 / 4314 £ 0,4 2 £ 30 0 30 4 2 56
4318 £ 0,4 2 £ 60 0 60 4 2 56
4312 / 4314 VARIOFAN £ 0,4 2 £ 30 0 30 4 2 57
4318 VARIOFAN £ 0,4 2 £ 60 0 60 4 2 57
4400 £ 0,4 2 £ 30 0 30 4 2 58/59
4100 N £ 0,4 2 £ 30 0 30 4 2 60
4100 NHH...NH6 £ 0,4 2 £ 60 0 60 10 2 61
4100 NH7...NH8 £ 0,4 2 £ 60 0 60 20 3 62
DV 4100 £ 0,4 2 £ 30 0 30 4 2 63
5200 N £ 0,4 2 £ 30 0 30 4 2 64
DV 5200 £ 0,4 2 £ 30 0 30 4 2 65
Subject to alterations
2016-01

168
Information
Available on request:
– Electrically isolated sensor and signal circuit
– Varying voltage potentials for power and logic circuit

DC axial fans
DC centrifugal fans
Pulses per revolution
Perm. sink current
Condition: Isource

voltage UBS max.


Sensor operating

Fan description
Condition: Isink
Speed signal

Speed signal

Basic type
Isink max.
US High
US Low

Signal data

Type VDC mA VDC mA VDC mA Page

DC fans - specials
5112 N £ 0,4 2 £ 15 0 5 20 2 66
5114 N / 5118 N £ 0,4 2 £ 60 0 60 20 2 66
5300 £ 0,4 2 £ 60 0 60 4 2 67
5300 TD £ 0,4 2 £ 60 0 60 20 6 68
7112 N / 7118 N £ 0,4 2 £ 60 0 60 20 2 69
7114 N £ 0,4 2 £ 30 0 30 20 2 69
7200 N £ 0,4 2 £ 15 0 15 20 2 70

ACmaxx / EC fans
6400 £ 0,4 2 £ 60 0 60 20 2 71
6300 TD £ 0,4 2 £ 60 0 60 20 6 75
6300 N £ 0,4 2 £ 60 0 60 20 6 76
6300 NTD £ 0,4 2 £ 60 0 60 20 6 77
6300 £ 0,4 2 £ 60 0 60 20 2 78
DV 6300 TD £ 0,4 2 £ 60 0 60 20 6 80
2200 FTD £ 0,4 2 £ 60 0 60 20 6 81
RL 48 £ 0,4 2 £ 30 0 30 4 2 97

AC axial fans
RL 65 £ 0,4 2 £ 30 0 30 4 2 98
RL 90 N £ 0,4 2 £ 30 0 30 4 2 99
RLF 100 £ 0,4 2 £ 30 0 30 4 2 100
RG 90 N £ 0,4 2 £ 30 0 30 4 2 101
RG 125 N £ 0,4 2 £ 30 0 30 4 2 102
RG 140 N £ 0,4 3 £ 60 0 60 4 2 103
RG 160 N £ 0,4 2 £ 30 0 30 20 2 104 AC centrifugal fans
RG 160 NTD £ 0,4 2 £ 60 0 60 20 6 105
RG 190 TD £ 0,4 2 £ 60 0 60 20 6 106
RG 220 TD £ 0,4 2 £ 60 0 60 20 6 107
RG 225 TD £ 0,4 2 £ 60 0 60 20 6 108
RET 97 TD £ 0,4 2 £ 60 0 60 20 6 109
REF 100 £ 0,4 2 £ 30 0 30 4 2 110
RER 120 TD £ 0,4 2 £ 60 0 60 20 6 112
Accessories

RER 133 TD £ 0,4 2 £ 60 0 60 20 6 117


RER 160 NTD £ 0,4 2 £ 60 0 60 20 6 119
REF 175 TD £ 0,4 2 £ 60 0 60 20 6 120
RER 175 TD £ 0,4 2 £ 60 0 60 20 6 121
RER 190 TD £ 0,4 2 £ 60 0 60 20 6 122
RER 220 TD £ 0,4 2 £ 60 0 60 20 6 128
Note:
With these fan options, deviations in regard to temperature range, voltage
RER 225 TD £ 0,4 2 £ 60 0 60 20 6 129 range and power consumption are possible compared with standard fan
Subject to alterations
Representatives

data.
2016-01

169
Speed signal /12

– Speed-proportional square-wave signal for external speed monitoring of fan motor


– 2, 3 or 6 pulses per revolution
– TTL-compatible
– Integrated pull-up resistor
– Connection via separate lead
– The sensor signal also serves as a major comparison variable for setting and maintaining
the setpoint speed for interactive or controlled cooling with one or more interconnected
fans.

Electrical connection

Perm. sink current


Condition: Isource

Fan description
Condition: Isink
Speed signal

Speed signal

Basic type
Isink max.
US High
US Low
Signal data

Type VDC mA VDC mA mA Page


614 N/12 GM £ 0,4 1 2,5–5,5 1 1 39
All voltages measured to ground. 618 N/12 N £ 0,4 1 2,5–5,5 1 1 39

8412 N/12 H £ 0,4 1 2,5–5,5 1 1 44

4412 F/12 GM £ 0,4 1 2,5–5,5 1 1 53


4418 F/12 £ 0,4 1 2,5–5,5 1 1 53

4312 /12 M £ 0,4 1 2,5–5,5 1 1 56


4314 /12 £ 0,4 1 2,5–5,5 1 1 56

4182 N/12 X £ 0,4 1 2,5–5,5 1 1 60


Subject to alterations

Note:
With these fan options, deviations in regard to temperature range, voltage range
and power consumption are possible compared with standard fan data.
2016-01

170
Information
Available on request:
– Electrically isolated sensor and signal circuit
– Varying voltage potentials for power and logic circuit

DC axial fans
DC centrifugal fans
Perm. sink current
Condition: Isource

Fan description
Condition: Isink
Speed signal

Speed signal

Basic type
Isink max.
US High
US Low

DC fans - specials
Signal data

Type VDC mA VDC mA mA Page


7214 N/12 £ 0,4 2 2,5–5,5 1 £ 20 70

6424/12 H £ 0,4 2 2,5–5,5 1 £ 20 71

DV 6424/12 £ 0,4 2 4,5–5,25 2 £ 12 73


DV 6448/12 £ 0,4 2 4,5–5,25 2 £ 12 73

ACmaxx / EC fans
RG 125-19/12 N/12 £ 0,4 1 2,5–5,5 1 £1 103

RG 160-28/12 N/12 £ 0,4 2 2,5–5,5 1 £5 104


RG 160-28/18 N/12 £ 0,4 2 2,5–5,5 1 £ 20 104

RER 125-19/12 N/12 £ 0,4 1 2,5–5,5 1 £1 116

RER 160-28/12 N/12 £ 0,4 2 2,5–5,5 1 £5 118


RER 160-28/18 N/12 £ 0,4 2 2,5–5,5 1 £ 20 118

AC axial fans
Subject to alterations

Note:
With these fan options, deviations in regard to temperature range, voltage
range and power consumption are possible compared with standard fan data.

AC centrifugal fans
Accessories
Representatives
2016-01

171
Alarm signal /17

– Alarm signal for speed monitoring


– Signal output via open collector
– The fan emits a high continuous signal during trouble-free operation within the permissible
voltage range.
– Low signal when speed limit is not reached
– After elimination of fault, the fan returns to its setpoint speed;
the alarm signal reverts to high.

voltage UBA max.

Max. permissible
Alarm operating-
voltage UA High
voltage UA Low

Fan description
Speed limit nG
Alarm start-up
Alarm output-
Alarm output

delay time t6
Sink current

Basic type
Condition:

Condition:

Condition:

Condition:

Condition:
Isource
Isink =

Alarm
signal data

Type VDC mA VDC mA VDC mA s rpm Page


8318 /17 £ 0,4 n < nG 2 £ 60 n > nG 0 60 20 £ 15 * 1500 ± 100 46

8318 /17 H £ 0,4 n < nG 2 £ 60 n > nG 0 60 20 £ 15 * 1500 ± 100 46

4318 /17 £ 0,4 n < nG 2 £ 60 n > nG 0 60 20 £ 15 * 850 ± 100 56

4184 N /17 X £ 0,4 n < nG 2 £ 60 n > nG 0 60 20 £ 15 * 1500 ± 100 60

Subject to alterations

Note:
Fans that come with these fan specials in addition could have different temperature ranges, different voltage ranges and
different power consumptions compared to standard fans without specials.

Electrical connection Supply voltage

All voltages measured to ground.


External load resistor Ra from UA to UBA required. t 6 = Alarm signal suppression during start-up
* n < speed limit nG by braking or locking.
2016-01

172
Information
Available on request:
– Integrated signal latching for subsequent recognition of short-time faults (Latch)
– Alarm circuit open collector or TTL

DC axial fans
– Electrically isolated for maximum device safety
Defects in the power circuit do not affect the alarm circuit.

DC centrifugal fans
voltage UBA max.

Max. permissible
Alarm operating-
voltage UA High
voltage UA Low

Fan description
Speed limit nG
Alarm start-up
Alarm output-
Alarm output

delay time t6
Sink current

Basic type
Condition:

Condition:

Condition:

Condition:

Condition:
Isource
Isink =

DC fans - specials
Alarm
signal data

Type VDC mA VDC mA VDC mA s rpm Page


4312/17 MT £ 0,4 n < nG 2 £ 60 n > nG 0 60 20 £ 15 * 1500 ± 100 57
VARIOFAN

4312/17 T £ 0,4 n < nG 2 £ 60 n > nG 0 60 20 £ 15 * 1500 ± 100 57


VARIOFAN

ACmaxx / EC fans
4314/17 T £ 0,4 n < nG 2 £ 60 n > nG 0 60 20 £ 15 * 1150 ± 100 57
VARIOFAN

4318/17 T £ 0,4 n < nG 2 £ 60 n > nG 0 60 20 £ 15 * 850 ± 100 57


VARIOFAN

7214 N/17 £ 0,4 n < nG 2 £ 60 n > nG 0 60 15 £ 15 * 1330 ± 60 70

Subject to alterations * After switching on UB

AC axial fans
Note:
Fans that come with these fan specials in addition could have different temperature ranges, different voltage ranges and
different power consumptions compared to standard fans without specials.

AC centrifugal fans
Accessories
Representatives
2016-01

173
Alarm signal /19

– Alarm signal for speed monitoring


– Signal output via open collector
– The fan emits a continuous high signal during nominal operation.
– High signal when speed limit is not reached
– After elimination of fault, the fan returns to its setpoint speed; the alarm signal
reverts to low.

voltage UBA max.

Max. permissible
Alarm operating-
voltage UA High
voltage UA Low

Fan description
Speed limit nG
Alarm start-up
Alarm output-
Alarm output

delay time t6
Sink current

Basic type
Condition:

Condition:

Condition:

Condition:

Condition:
Isource
Isink =

Alarm
signal data

Type VDC mA VDC mA VDC mA s rpm Page


8314/19 H £ 0,4 n > nG 2 £ 60 n < nG 0 60 20 £ 15 * 1500 ± 100 46

4312/19 £ 0,4 n > nG 2 £ 60 n < nG 0 60 20 £ 15 * 1500 ± 100 56

7214 N/19 £ 0,4 n > nG 2 £ 60 n < nG 0 60 10 £ 15 * 1800 ± 20 70

RLF 100-11/14/19 £ 0,4 n > nG 2 £ 28 n < nG 0 28 10 £ 15 * 1900 ± 100 100

RER 101-36/18N/19 HH £ 0,4 n > nG 2 £ 28 n < nG 0 28 10 £ 15 * 1900 ± 100 111

Subject to alterations * After switching on UB

Note:
Fans that come with these fan specials in addition could have different temperature ranges, different voltage ranges and
different power consumptions compared to standard fans without specials.

Available on request:
– Integrated signal latching for subsequent recognition of short-term faults (Latch).
– Alarm circuit open collector or TTL.
– Electrically isolated for max. device safety; defects in power circuit have no effect on the alarm circuit.

Electrical connection Supply voltage

All voltages measured to ground. t 6 = Alarm signal suppression during start-up.


External load resistor Ra from UA to UBA required. * n < Speed limit nG by braking or locking.
2016-01

174
Information
Alarm signal /37
Go- / NoGo-alarm

– Alarm signal for speed monitoring


– Signal output via open collector
– The fan emits a continuous high signal during nominal operation.

DC axial fans
– Low signal when speed limit is not reached
– After elimination of fault, the fan returns to its setpoint speed; the alarm signal
reverts to high.

DC centrifugal fans
voltage UBA max.

Max. permissible
Alarm operating-
voltage UA High
voltage UA Low

Fan description
Speed limit nG
Alarm output-
Alarm output

Sink current

Alarm delay

Basic type
Condition:

Condition:

Condition:

Condition:

Condition:
Isource
Isink =

time t7

DC fans - specials
Alarm
signal data

Type VDC mA VDC mA VDC mA s rpm Page


8412 N/37 GMLV £ 0,4 n £ nG 2 £ 28 n > nG 0 28 10 <1 * 0 45

3412 N/37 GV £ 0,4 n £ nG 2 £ 28 n > nG 0 28 10 <1 * 0 49

Subject to alterations * After switching on UB

ACmaxx / EC fans
Note:
Fans that come with these fan specials in addition could have different temperature ranges, different voltage ranges and
different power consumptions compared to standard fans without specials.

AC axial fans
Available on request:
– Alarm circuit TTL compatible.

Electrical connection Supply voltage


AC centrifugal fans
Accessories

All voltages measured to ground. * Speed limit nG = 0 apm


External load resistor Ra from UA to UBA required.
Representatives
2016-01

175
Alarm signal /39
Go- / NoGo-alarm

– Alarm signal for speed monitoring


– Signal output via open collector
– The fan emits a continuous high signal during nominal operation.
– High signal when speed limit is not reached
– After elimination of fault, the fan returns to its setpoint speed;
the alarm signal reverts to low.

voltage UBA max.

Max. permissible
Alarm operating-
voltage UA High
voltage UA Low

Fan description
Speed limit nG
Alarm output-
Alarm output

Sink current

Alarm delay

Basic type
Condition:

Condition:

Condition:

Condition:

Condition:
Isource
Isink =

time t7
Alarm
signal data
Type VDC mA VDC mA VDC mA s rpm Page
412/39 £ 0,5 n > nG 2 £ 28 n = nG 0 28 10 <1 * 0 33

612 F/39 H £ 0,5 n > nG 2 £ 28 n = nG 0 28 10 <1 * 0 36


614 N/39 M £ 0,5 n > nG 2 £ 28 n = nG 0 28 10 <1 * 0 39
618 N/39 N £ 0,5 n > nG 2 £ 28 n = nG 0 28 10 <1 * 0 39

3412 N/39 H £ 0,5 n > nG 2 £ 28 n = nG 0 28 10 <1 * 0 48


3414 N/39 HH £ 0,5 n > nG 2 £ 28 n = nG 0 28 10 <1 * 0 48
4412 F/39 GL £ 0,5 n > nG 2 £ 28 n = nG 0 28 10 <1 * 0 53
4412 F/39 M £ 0,5 n > nG 2 £ 28 n = nG 0 28 10 <1 * 0 53
4414 F/39 £ 0,5 n > nG 2 £ 28 n = nG 0 28 10 <1 * 0 53
4414 FN/39 H £ 0,4 n > nG 2 £ 30 n = nG 0 30 4 <1 * 0 55

Subject to alterations * After switching on UB

Note:
Fans that come with these fan specials in addition could have different temperature ranges, different voltage ranges and
different power consumptions compared to standard fans without specials.

Electrical connection Supply voltage

All voltages measured to ground * Speed limit nG = 0 apm


External load resistor Ra from UA to UBA required.
2016-01

176
Information
Vario-Pro®

– ”Software instead of hardware“ – aptly describes the unique fan concept,


equipped at the plant with tailor-made intelligence for cooling electronics.
– Flexible configuration using software, allows quicker availability, sampling from

DC axial fans
the factory and the ability to supply customer-specific solutions in any quantity.

DC centrifugal fans
Vario-Pro-Features

External Speed setting Alarm and tachometer functions Motor management

DC fans - specials
– Speed setting via temperature, PWM or – Optional alarm and/or tachometer function – High control accuracy due to digital
analog control voltage – Selectable alarm speed limit (with motor management
See page 178 (Speed setting) hysteresis) and alarm delay time – Higher operating efficiency due to
– Description of speed curve with up to – Latching of alarm signal optimum adaptation of motor hardware
14 selectable interpolation points – Delay only when starting or permanently and software
Linear interpolation between the points active
– Zero speed possible – ”High“ or ”Low“ output signal in case of
– Recognition of sensor failure: In case of alarm

ACmaxx / EC fans
loss of sensor, the fan operates at – Optional alarm if temperature sensor fails
programmable (fail-safe) speed. – Optional alarm in case of excess
temperature

Fan series Page Fan series Page Fan series Page

AC axial fans
620 37 4100 NH 7-8 62 6300 78
8400 N 44 DV 4100 63 DV 6300 TD 80
8300 46 5200 N 64 RL 90 N 99
8200 J 47 DV 5200 65 RLF 100 100
3400 N 48 5100 N 66 RG 90 N 101
3300 N 50 5300 67 RG 125 N 102
3200 J 51 7100 N 69 RG 140 N 103 AC centrifugal fans
3250 J 52 7200 N 70 RG 160 N 104
4400 FN 55 6400 71 REF 100 110
4300 56 DV 6400 73 RER 101 N 111
4100 N 60 6300 N 76 RER 125 N 116
4100 NH...NH6 61 6300 NTD 77 RER 160 N 118
Accessories
Representatives
2016-01

177
Speed setting via
temperature sensor
– The control variable is a temperature sensor which is either integrated into the fan or
connected to an additional control wire.

External temperature sensor type T Internal temperature sensor type I

– Ext. NTC type LZ370 (p. 257) is required – NTC integrated into the fan hub
(to be ordered seperatly)

internal ref. internal ref.

Standard speed-temperature curve Optionally available with customer specific


for type T and type I temperature-speed control curve

n max n max

n min

n min

30°C 50°C T min T max

nmin  1/2 nmax nmin  800 1/min nmax model-dependent


Tmin  30 °C; Tmax = 50 °C Tmin  5 °C Tmax ≤ 85 °C, model-dependent
2016-01

178
Speed setting with

Information
control voltage or PWM
– The control variable is a PWM signal or analog control voltage.

DC axial fans
DC centrifugal fans
Speed setting via analog control voltage type A Speed setting via PWM type P

– Standard control range 0 ... 10 V – Standard PWM signal in two versions


a) PWM frequency, mainly 1– 10 kHz (0–100%),
Open collector input

DC fans - specials
b) Four-wire interface in accordance with Intel specifications
for 12 VDC fans, PWM frequency 25 kHz, incl. speed signal /2

internal ref.

ACmaxx / EC fans
Typical input resistance >10 k

– Optional with potentiometer

AC axial fans
internal ref.

Internal reference = +5V AC centrifugal fans


R1 typical 4.7...10 k
R2 typical 100 k

Standard curve P / A Optionally available with customer specific


P / A speed control curve
Accessories
Representatives
2016-01

179
Speed setting via
multi-option control input
– Customer can operate input either with PWM signal, analog voltage, external temperature
control module or resistor.
– The control signal-speed characteristics of the fan differ from the standard curve of the
A and P inputs (see p. 179).
– To set up maximum speed, the control wire must be connected to UB.
– The control input is usually combined with an open collector tachometer
(Type /2, see page 168).

Speed setting via multi-option control input type 0


Notes on various control possibilities and their applications
Maximum ripple
± 3.5%
red

33 K 4,7 K
Lin/PWM control input
0-10 VDC / PWM
violet
Counter

Tach output Isink max. 10 mA


Controller
U pulses per revolution
PWM
10 K white
Alarm

12 V 12 V Speed display

GND
Temperature Speed setting Speed setting Full speed Speed setting blue
control module with
PWM 1 - 10 kHz potentiometer 1 V - 10 V
50002-1-0174
50003-1-0174
100% PWM -> n=max 10 V -> n =max
approx. 10% PWM -> n=min approx. 1 V -> n = min
< 10% PWM -> n=0 < 1 V -> n = 0

start up at > 14 % start up at > 1.4 V

Customer circuit Connection Fan

Line 1
0-10 V
Tacho

PWM
GND
+

red blue white violet

Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 + red Maximum ripple ± 3.5 % 1 Tach white Tach output:
GND blue GND 3 pulses / revolution
0-10 V / PWM violet Control input (Impedance 100 k)
2016-01

180
Information
Protected fans
against environmental influences

– Capable to fulfill special requirements for a broad range of applications


– Resistant to environmental influences, such as dust, splash water, humidity, spray water and
salt fog

DC axial fans
– Highly competent solutions for adapting fans to environmental conditions

DC centrifugal fans
Moisture protection Salt fog protection
Coated motor and printed circuit board protects against humidity and Salt fog is extremely demanding on the resistance of the product.
condensation. ebm-papst makes use of technologies that protect fans and blowers

DC fans - specials
from salt fog reliably and durably.
Degree of protection: IP 54 / IP 68
In the degree of protection IP 54, the motor and circuit boards are coated Stainless steel bearings
and therefore protected against spray water and moisture. Special bearings made of stainless steel provide additional protection.
The degree of protection IP 68 is important for ebm-papst products, as it
ensures a high degree of protection for the encapsulated motor and
electronic against foreign bodies and water, whilst protecting the user
against potential hazards upon contact. Degree of protections higher than

ACmaxx / EC fans
IP 68 are possible upon request.

The available solutions could be different depending on the fan size. We would be glad to
develop solutions tailored to the demands of your application.

Degree of protection – IP code*

AC axial fans
Protection against foreign bodies and accidental contact (first digit) Water protection (second digit)
X No protection X No protection
1 Protection against foreign bodies > 50 mm (back of the hand) 1 Protection against dripping water or condensation
2 Protection against foreign bodies > 12 mm (finger) 2 Protection against dripping water, fans tilted 15° from vertical
3 Protection against foreign bodies > 2,5 mm (tool) 3 Protection against water spray up to 60° from vertical
4 Protection against foreign bodies > 1 mm (wire) 4 Protection against water spray from all sides
AC centrifugal fans
5 Protection against dust in harmful quantities 5 Protection against low-pressure water jets
6 Dust-proof 6 Protection against high-pressure water jets
7 Protection against temporary submersion (15 cm - 1 m)
8 Protection against continuous submersion

* IP = International degree of protection marking


Accessories
Representatives
2016-01

181
2016-01

182
Information
ACmaxx / EC fans

DC axial fans
Technical information about ACmaxx 184
Overview 187
ACmaxx axial fans 188

DC centrifugal fans
GreenTech EC-compact fans 192
Energy-saving axial fans 194
EC axial fans 196
ACmaxx in-line duct fan 200

DC fans - specials
ACmaxx / EC fans
AC axial fans
AC centrifugal fans
Accessories
Representatives
2016-01

183
ACmaxx / EC fans

Technical information
about ACmaxx / GreenTech EC-compact fans

AC ACmaxx ACi

Progress made by ebm-papst Independent of mains frequency and mains voltage


The best example: The ACmaxx fans from ebm-papst, which, thanks to an The ACmaxx and GreenTech EC-compact fans are prepared for direct
ingenious yet simple improvement over conventional AC fans, provide connection to wide ranges of AC voltages and frequencies. The speed,
substantial benefits. and thus
The aim in developing the new ACmaxx series was to raise the technology important properties of the fan such as air flow and noise, are
standard of the conventional AC fan significantly and, in the process, independent of the power frequency and do not change, even within
facilitate the transition to the new technology by retaining the overall the defined voltage range. Voltage fluctuations in the power system are
mounting dimensions. In short, to ensure the fans can be replaced 1:1 automatically compensated for.
without any peripheral changes or changes to the voltage situation.
ebm-papst offers two generations of ACmaxx products that meet Long service life
different needs. The efficiency of ACmaxx and GreenTech EC-compact fan motors is up to
75% higher than that of conventional AC fan variants. This not only saves
What ACmaxx and GreenTech EC-compact fan have in common: energy, it also means less self-heating in the motor. The reduced
Energy efficiency heating has a direct, positive effect on the bearing system, which is why
The drive concept is based on state-of-the-art GreenTech EC technology the fans have a service life that is up to 85% longer! This also extends
with outstanding motor efficiency. Compared to AC fans of the same size, the service and maintenance intervals significantly. The expense of
ACmaxx energy consumption is up to 77% lower–for higher cooling replacement fans, and even more expensive downtimes, are kept to a
capacity! Just the energy savings means that the products pay for manageable minimum.
themselves after only a few months. The savings over the entire service
life, especially in systems with multiple fans, is considerable.
2016-01

184
Information
ACmaxx / EC fans

DC axial fans
DC centrifugal fans
Technical information
about ACmaxx / GreenTech EC-compact fans

AC ACmaxx ACi

DC fans - specials
Safety GreenTech EC-compact fan is more efficient!
• Safety certifications: UL, CSA and VDE 0805 / EN60950. ACmaxx saves energy, and the GreenTech EC-compact fan generation
VDE 0700 / EN60335 on request. saves even more. While an AC fan at 50 Hz can barely reach an overall
• Our fans have the CE mark of conformity. efficiency of 5-6%, the ACmaxx makes it to approx. 20-25%. With the new
• EMC protection: GreenTech EC-compact fans ACi 4400, a remarkable level of up to 30% is
> EN61000-4-4 Level 1 (1 kV or 2 kV)B reached. This is the result of the optimisation of the entire package made

ACmaxx / EC fans
> EN61000-4-2 Level 8 kV/15 kV or 4 kV/8 kV up of drive, electronics, AC/DC conversion and aerodynamics. Thus the
> EN61000-4-3 new GreenTech EC-compact fans series boasts energy savings of almost
> EN61000-4-6 75% compared to the corresponding AC fan, thus providing significantly-
> EN61000-4-8 higher savings than the 40% level of the old AC 4300 generation.
> EN55022 Class B

Ambient influences
AC fans are extremely common and are used in a wide variety of

AC axial fans
applications. In control cabinet cooling, beer coolers, cooling cabinets,
wood-burning stoves, medical devices – all have different requirements
for resistance to ambient influences. ACmaxx and GreenTech EC-compact
fans offer the same features for Humidity protection, splash water and
rough ambient conditions.

Particular design features of the GreenTech EC-compact fan (ACi 4400): AC centrifugal fans
GreenTech EC-compact fan is more compact!
As large as existing AC fans – and not a bit larger. This is the most GreenTech EC-compact fan is quieter!
outstanding feature of the new GreenTech EC-compact fans ACi 4400. The GreenTech EC-compact fan ACi 4400 is quieter! Quieter than AC fans
Even in the hub area, the fan does not differ from typical and quieter than the existing ACmaxx generation. The reason for this are
119 x 119 x 38 mm AC fans. Out with the AC, in with the GreenTech the optimised aerodynamics and the drive, which is optimised for mini-
EC-compact fans ACi 4400 – it's that simple. mum structure-borne noise. Thus the fan is only half as loud at compara-
ble air performance, and is up to 6 dB(A) quieter at some operating points.
Accessories

Speed independent of voltage and frequency


For the GreenTech EC-compact fans ACi 4400, the speed, and thus the air
flow and operating noise, are independent of the supply voltage and
power frequency.
Versions are available for 115 VAC with a voltage range from 85 to
132 VAC and 230 VAC with a voltage range of 195 to 265 VAC. Voltage
Representatives

fluctuations and frequency differences in the power system are


ACmaxx ACi compensated for automatically.
2016-01

185
ACmaxx / EC fans

Technical information
about ACmaxx / GreenTech EC-compact fans

AC ACmaxx ACi

Particular design features of the ACmaxx: setting to long-term function checks using an alarm or speed signal
outputs, ACmaxx offers optional interfaces that allow you to monitor
Prepared for all common AC voltages operation quickly and easily.
These types have a very wide voltage range from 85 to 265 VAC – the
global voltage range, so to speak. This enables the fan to be used around You can find further information about these fan options in the
the world, opening up large savings potentials. In addition to reduced "Specialised fans" chapter, starting on page 161.
logistics effort and stock-keeping, worldwide availability is key. ACmaxx is Or you can simply contact our application engineers to discuss your ideal
compatible with every supply voltage–no switching needed. From 85 to ACmaxx or GreenTech EC-compact fan.
265 volts and mains frequencies of 50 and 60 hertz. Voltage fluctuations
in the power system are automatically compensated for.

Higher performance
Unlike conventional AC technology, the state-of-the-art drive concept of
this fan series is not linked to a fixed power frequency. This allows the
motor speed to be increased over a wide range. Thus ACmaxx provides
significantly higher air flow and significantly increased pressure.

Higher flexibility
The flexibility of ACmaxx is one-of-a-kind. With its intelligent features,
ACmaxx can be individually adapted to the specific application: standby
mode, overload mode at peak times or night reduction all the way to
temperature-controlled quiet operation are all possible. From speed
2016-01

186
Information
Fans for AC operation

Overview of air performance

DC axial fans
Dimension

Air flow
Series

Page
3 3 10 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 2500
mm mm/h/h

DC centrifugal fans
c 80 x 32 AC 8300 80 188
c 92 x 38 AC 3200 J 144 109 189
c 119 x 25 AC 4400 FN 205 110 190
c 119 x 32 AC 4300 204 18 191
c 119 x 38 ACi 4400 100...175 192
Ø 172 x 51 AC 6200 N 350 193
Ø 130 W1G 130 220...370 194

DC fans - specials
Ø 200 W3G 200 560...1000 196
Ø 250 W3G 250 900...1700 198
Ø 98,5 x 130 AC 100 40...135 200
Subject to alterations

Overview of technically feasible designs

ACmaxx / EC fans
s
aring

nsor
nsor
all be

put
re se
re se
d

rol in
gs / b

spee

put

n
eratu
ratu
put

tion
ectio
larm

cont
ol in
earin

limit

rol in

rotec
e
temp

prot
emp
Go-a
CSA

eve b

ontr
nal

tion
with
on

cont
d sig

fog p
= 54
idity
nal t

og c
i-op
, UL,

/ No
c sle

rnal
ensi

Alarm

PWM

IP 68

Page
Spee

Hum
Sinte

Mult
Inter

Anal
Exte

IP >
Dim

VDE

Salt
Go-

AC axial fans
ACmaxx / ACi axial fans
mm Series OPTIONAL p.

c 80 x 32 AC 8300 yes • • • • • • • – • • – • 188


c 92 x 38 AC 3200 J no • • • • • • • – • • – • 189
c 119 x 25 AC 4400 FN yes • • • • • • • – • – – – 190
c 119 x 32 AC 4300 yes • • • • • • • – • • • • 191
AC centrifugal fans
c 119 x 38 ACi 4400 yes – – – – – – – – • • – • 192
Ø 172 x 51 AC 6200 N yes • • • • • • • – • • – • 193
Ø 98,5 x 130 AC 100 * – – – – – – – – • • – – 200
Subject to alterations

– not yet available Sleeve bearings


• available Ball bearings
* Partially granted, partially in registration stage.
Accessories

Please note that these special versions are not possible for all voltages and speeds, and not in all combinations.
The special versions are designed for specific customers and projects. As a rule they are not available off the
shelf and are tied to minimum volumes.
Please consult your customer support representative about the feasibility of your special variant.
Representatives
2016-01

187
max. 80 m /h 3
ACmaxx axial fans
 80 x 32 mm

– Material: Housing: GRP1) (PBTP) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Alarm with limit speed
TR 64 - External temperature sensor
– Highlights: Universally usable for all - Internal temperature sensor
mains voltages between 85 - PWM control input
and 265 VAC - Analog control input
– Mass: 325 g - Humidity protection
- Salt fog protection
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series AC 8300

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Frequency
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

AC 8300 H 80 47 115 / 230 50 / 60 85 ... 265 48 6,2 8,3 5 000 -20...+75 55 000 / 20 000 92 500 ➀
Subject to alterations

Speed variants available on request.

5 22
32 + 0,3

64 + 0,5

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or tin-p
lated
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

188 p. 244
Information
max. 144 m /h 3
ACmaxx axial fans
 92 x 38 mm

– Material: Housing: GRP1) (PBTP) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Alarm with limit speed
TR 64 - External temperature sensor
– Highlights: Universally usable for all - Internal temperature sensor
mains voltages between 85 - PWM control input
and 265 VAC - Analog control input
– Mass: 325 g - Humidity protection
- Salt fog protection

DC centrifugal fans
- Degree of protection: IP 54
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series AC 3200 J

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Frequency
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

AC 3200 JH 144 85 115 / 230 50 / 60 85 ... 265 55 6,4 12 6 800 -20...+70 70 000 / 35 000 117 500 ➀
Subject to alterations

Speed variants available on request.

ACmaxx / EC fans
AC axial fans
54.2 + 0.15
61.7+ 0.2

6+ 0.3 6+ 0.3 AC centrifugal fans


38 + 0.5
70.7 + 0.8
0.3

tin-pla
ted
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
Representatives

fitted. For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

p. 244
189
max. 205 m /h 3
ACmaxx axial fans
 119 x 25 mm

– Material: Housing: GRP1) (PBTP) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Counter-clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Universally usable for all - PWM control input
mains voltages between - Analog control input
85 and 265 VAC - Humidity protection
– Mass: 370 g

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series AC 4400 FN

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Frequency
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

AC 4400 FNN 205 121 115 / 230 50 / 60 85 ... 265 53 6,2 12 4 850 -20...+70 60 000 / 30 000 102 500 ➀
Subject to alterations

Speed variants available on request.

25.4 + 0.15

57.9 + 0.5

tin-pla
ted

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

190 p. 244
Information
max. 204 m /h 3
ACmaxx axial fans
 119 x 32 mm

– Material: Housing: GRP1) (PBTP) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Go- / NoGo-alarm
– Connection: Via single wires AWG 22, - Alarm with limit speed
TR 64 - External temperature sensor
– Highlights: Universally usable for all - Internal temperature sensor
mains voltages between - PWM control input
85 and 265 VAC - Analog control input
– Mass: 325 g - Humidity protection

DC centrifugal fans
- Salt fog protection
- Degree of protection: IP 54 / IP 68
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series AC 4300

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Frequency
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

AC 4300 H 204 120 115 / 230 50 / 60 85 ... 265 51 6,4 12 3 400 -20...+70 45 000 / 22 500 75 500 ➀
Subject to alterations

Speed variants available on request.

ACmaxx / EC fans
Rotorüberstand
Rotor protusion
0,4 mm
max. 0,4
max. mm

AC axial fans
52,7
54
O

AC centrifugal fans
22
64 + 0,6
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the tin-pla
values have to be checked and reviewed once installed or ted
Representatives

fitted. For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

p. 244
191
max. 175 m /h 3
GreenTech EC-Compact fans
 119 x 38 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Humidity protection
– Direction of rotation: Clockwise, seen on rotor - Salt fog protection
– Connection: via 2 flat plugs 2,8 x 0,5 mm - Degree of protection: IP 54
flying leads optional
– Highlights: Fully integrated converter
and fan electronics
– Mass: 250 g

1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series ACi 4400

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Frequency
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

ACi 4420 ML 100 59 230 50 / 60 195...265 25 4,1 1,7 1 850 -20...+75 65 000 / 25 000 110 000 ➀
ACi 4420 N 147 86 230 50 / 60 195...265 36 4,9 2,8 2 700 -20...+75 65 000 / 25 000 110 000 ➁
ACi 4420 H 160 94 230 50 / 60 195...265 39 5,1 3,2 3 000 -20...+75 65 000 / 25 000 110 000 ➂
ACi 4420 HH 175 103 230 50 / 60 195...265 42 5,3 4,6 3 300 -20...+75 65 000 / 25 000 110 000 ➃
ACi 4410 HH 175 103 115 50 / 60 85...132 42 5,3 4,4 3 300 -20...+75 65 000 / 25 000 110 000 ➃
Subject to alterations

38 +0,5
6 +0,3 6 +0,3

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles Connection cables


2016-01

192 p. 244 p. 255


Information
max. 350 m /h 3
ACmaxx axial fans
Ø 172 x 51 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Exhaust over struts - Speed signal

DC axial fans
– Direction of rotation: Counter clockwise, seen - Go- / NoGo-alarm
on rotor - Alarm with limit speed
– Connection: Via single wires AWG 22, - External temperature sensor
TR 64 - Internal temperature sensor
– Highlights: Universally usable for all - PWM control input
mains voltages between - Analog control input
85 and 265 VAC, 50-60 Hz - Humidity protection
Housing with grounding lug - Salt fog protection

DC centrifugal fans
for screw M4 x 8 (Torx) - Degree of protection: IP 54
– Mass: 900 g
1) Fibreglass-reinforced plastic

Sintec sleeve bearings

Life expectancy L10IPC


Sound pressure level

Service life L10 (40 °C)

Service life L10 (Tmax)


Series AC 6200 N

Temperature range
Sound power level

(40 °C) see page 17


ebm-papst Standard

ebm-papst Standard
Nominal voltage

Nominal speed
Voltage range

Ball bearings

Input power
Frequency
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

AC 6200 NM 350 206 115 / 230 50 / 60 85 ... 265 50 5,7 14 2 850 -20...+70 80 000 / 40 000 135 000 ➀
Subject to alterations

Speed variants available on request.

ACmaxx / EC fans
83,3 +0,6
166

AC axial fans
0,8 0,8
63,7
74

10

7,5
7,5

AC centrifugal fans

15 30,5 +0,2
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis. tin-pla
The acoustic values are only valid for the described measure- ted
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
8,2

values have to be checked and reviewed once installed or


de
ep

Representatives

fitted. For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

p. 244
193
max. 370 m /h 3
Energy-saving axial fans
Ø 130 mm

– Material: Wall ring: Plastic PP, fibreglass-reinforced


Blades: Plastic PA, fibreglass-reinforced
– Number of blades: 7
– Direction of air flow: "V", exhaust over struts
– Direction of rotation: Counter-clockwise, seen on rotor
– Degree of protection: IP 54
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Electrical connections
Max. back-pressure
Max. current draw(1)
Max. input power(1)

Perm. amb. temp.


Nominal voltage

Speed / rpm(1)
Frequency
Curve

Mass
Nominal data

Type Motor VAC Hz rpm W A Pa °C kg

W1G130-AA49 -01 M1G 055-AI A 1~ 115 50/60 3 200 24 0,38 90 -30..+60 0,75 p. 264 / J7)

W1G130-AA25 -01 M1G 055-AI B 1~ 230 50/60 3 200 24 0,19 90 -30..+70 0,75 p. 264 / J7)
(1)
Subject to alterations Nominal data in operating point with maximum load and 115 or 230 VAC

A n Ped I L WA
Curves: rpm W A dB(A)
B

A 1 3 200 23 0,38 63
A 2 3 200 24 0,38 61
A 3 3 200 24 0,38 60
A 4 3 200 24 0,38 63
A 5 2 800 16 0,26 60
A 6 2 800 16 0,26 58
A 7 2 800 16 0,26 57
A 8 2 800 16 0,26 60
B 1 3 200 23 0,19 63
B 2 3 200 24 0,19 61
B 3 3 200 24 0,19 60
B 4 3 200 24 0,19 63
B 5 2 800 16 0,13 60
B 6 2 800 16 0,13 58
B 7 2 800 16 0,13 57
B 8 2 800 16 0,13 60

Air performance measured as per: ISO 5801, Installation category A, in ebm-papst full nozzle and without protection against
accidental contact. Suction-side noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic
values given are only valid under the measurment conditions listed and may vary depending on the installation situation.
With any deviation to the standard setup, the specific values have to be checked and reviewed once installed or fitted!
For detailed information see http://www.ebmpapst.com/general conditions
2016-01

194
Information
– Motor protection: Via electronics and TOP
– Electrical connection: Plug-in connection on motor side
– Protection class: II

DC axial fans
– Product conforming
to standards: CE; EN 60335-1
– Approvals: VDE, GOST (are available); UL, CSA (are applied for)
– Speed: Using the programming unit 2 speeds between nmin and nmax can be programmed

DC centrifugal fans
DC fans - specials
ACmaxx / EC fans
AC axial fans
AC centrifugal fans
Accessories

❮ "V"

Connection lead (total length 450 mm)


is fitted ex works and can be detached.
Representatives

Connection leads Handheld Programmer Electrical connections


2016-01

p. 256 p. 256 p. 264


195
max. 1 000 m /h 3
EC axial fans
Ø 200 mm

– Material: Wall ring: Die-cast aluminium


Blades: Plastic PP
Rotor: Thick layer passivated
– Number of blades: 7
– Direction of air flow: "V", exhaust over struts
– Direction of rotation: Counter-clockwise, seen on rotor
– Degree of protection: Depending on installation and position(2)
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None, open rotor
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. back-pressure
Max. current draw(1)
Max. input power(1)

Technical features
Perm. amb. temp.
Nominal voltage

Speed / rpm(1)

and electrical
connection
Frequency
Curve

Mass
Nominal data

Type Motor VAC Hz rpm W A Pa °C kg

W3G200-HD01 -01 M3G 055-BD A 1~ 200-240 50/60 2 900 54 0,55 96 -25..+60 1,6 p. 260 / H3)

W3G200-HD01 -03 M3G 055-BD B 1~ 200-240 50/60 2 900 54 0,55 96 -25..+60 1,6 p. 261 / H4)
(1) (2)
Subject to alterations Nominal data in operating point with maximum load and 230 VAC Not suitable for permanent outdoor use, special version available on request.
0,40 in H2O

n Ped I L WA
Pa

Curves: rpm W A dB(A)


B
100 A
A 2 Speed stages Step 2 4
A 1 2 970 50 0,49 65
0,36

90 A 2 2 890 54 0,53 64
B Speed-controlled A 3 2 830 58 0,56 65
0,32

80 A
Step 1 8 A 4 2 900 54 0,55 70
0,28

70 3 A 5 2 645 36 0,37 62
A 6 2 575 39 0,40 61
0,24

60 A 7 2 530 42 0,42 62
7
A 8 2 500 43 0,43 67
0,20

50
B 1 2 970 50 0,49 65
2 890 54 0,53 64
0,16

40 2 B 2

B 3 2 830 58 0,56 65
0,12

6
30 B 4 2 900 54 0,55 70
0,08

20
0,04

10

5 1
pfs

0 100 200 300 400 500 cfm


qV 200 400 600 800 m3/h

Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side
noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under
the measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup,
the specific values have to be checked and reviewed once installed or fitted! For detailed information see
http://www.ebmpapst.com/general conditions
2016-01

196
Information
– Technical features: See electrical connections p. 260/61
– Touch current: <= 3.5 mA acc. to IEC 60990 (test circuit, illustration 4)
– Electrical connection Via terminal strip

DC axial fans
– Protection class: I (if customer has provided connection for protective earth)
– Product conforming
to standards: EN 60335-1, CE
– Approvals: VDE, cURUS

DC centrifugal fans
DC fans - specials
ACmaxx / EC fans
A B

AC axial fans
5
22

AC centrifugal fans
Accessories
Ø4.5 (8x)

Ø240 4 4
Ø260 80±0.3

"V" › "V" ›
Representatives

Guard grilles Electrical connections


2016-01

p. 245 p. 260/261
197
max. 1 700 m /h 3
EC axial fans
Ø 250 mm

– Material: Wall ring: Die-cast aluminium


Blades: Plastic PP
Rotor: Thick layer passivated
– Number of blades: 7
– Direction of air flow: "V", exhaust over struts
– Direction of rotation: Counter-clockwise, seen on rotor
– Degree of protection: Depending on installation and position(2)
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None, open rotor
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Max. back-pressure
Max. current draw(1)
Max. input power(1)

Technical features
Perm. amb. temp.
Nominal voltage

Speed / rpm(1)

and electrical
connection
Frequency
Curve

Mass
Nominal data

Type Motor VAC Hz rpm W A Pa °C kg

W3G250-HH07 -01 M3G 055-CF A 1~ 200-240 50/60 2 330 83 0,72 100 -25...+60 2,1 p. 260 / H3)

W3G250-HH07 -03 M3G 055-CF B 1~ 200-240 50/60 2 330 83 0,72 100 -25...+60 2,1 p. 261 / H4)
(1) (2)
Subject to alterations Nominal data in operating point with maximum load and 230 VAC Not suitable for permanent outdoor use, special version available on request.
in H2O

n Ped I L WA
Pa

B
Curves: A
rpm W A dB(A)
Step 2
0,40

100 4

A 2 Speed stages A 1 2 465 67 0,59 69


0,36

90 A 2 2 410 75 0,65 69
B Speed-controlled A 3 2 375 80 0,68 68
0,32

80
A 4 2 330 83 0,72 69
0,28

70 A 3 A 5 1 900 33 0,33 63
Step 1 A 6 1 880 37 0,37 63
8
0,24

60 A 7 1 860 40 0,38 62
A 8 1 850 42 0,40 63
0,20

50
B 1 2 465 67 0,59 69
7
2 410 75 0,65 69
0,16

40 2 B 2

B 3 2 375 80 0,68 68
0,12

30 B 4 2 330 83 0,72 69
6
0,08

20
0,04

10

5 1
pfs

0 100 200 300 400 500 600 700 800 900 1000 cfm
qV 200 400 600 800 1000 1200 1400 1600 m3/h

Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side
noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the
measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the
specific values have to be checked and reviewed once installed or fitted! For detailed information see
http://www.ebmpapst.com/general conditions
2016-01

198
Information
– Technical features: See electrical connections p. 260/261
– Touch current: <= 3.5 mA acc. to IEC 60990 (test circuit, illustration 4)
– Electrical connection Via terminal strip

DC axial fans
– Protection class: I (if customer has provided connection for protective earth)
– Product conforming
to standards: EN 60335-1, CE
– Approvals: VDE, cURUS

DC centrifugal fans
DC fans - specials
ACmaxx / EC fans
A B
20° 15°

AC axial fans
0
28

90
Ø2

AC centrifugal fans

PE N L
Accessories

Ø4.4+0.2(8x) Ø5.5+0.2(8x) 7 7
Ø295 80
Ø320

"V" › "V" ›
Representatives

Guard grilles Electrical connections


2016-01

p. 245 p. 260/261
199
max. 135 m /h 3
ACmaxx in-line duct fan
Ø 98,5 x 130 mm

– Material: Housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See chapter DC fans - specials)
– Direction of air flow: Intake over struts - Speed signal
– Direction of rotation: Clockwise, seen on rotor - PWM control input
– Connection: Via 3-pin terminal strip Europa - Analog control input 0…10 VDC
max. 1,5 mm2 - Humidity protection
– Highlights: Universally usable for all main - Degree of protection: IP 44 (IP 45
voltages between 85 and 265 possible depending on mounting
VAC, 50-60 Hz, Boost function position)
Vibration-isolated motor
Optional: new impeller for high
pressure
Two speeds over jumper adjustable
– Mass: 400 g 1) Fibreglass-reinforced plastic

Sintec sleeve bearings


Sound pressure level
Series AC 100

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Voltage range

Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Nominal data

Curve
Type high flow m3/h cfm VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

nominal 55 32 33 4,5 1,8 2 050 ➀


AC 100 MR 115/230 50-60 85...265 -10...+55 70 000 / 50 000
boost 90 53 40 5,0 3,8 3 150 ➂
nominal 80 47 35 4,7 2,5 2 750 ➁
AC 100 NR 115/230 50-60 85...265 -10...+55 70 000 / 50 000
boost 105 62 42 5,3 4,5 3 500 ➃
max. AC 100 HR* 135 79 115/230 50-60 85...265 tbd tbd 7,0 4 500 -10...+55 tbd ➄

Type high pressure m3/h cfm VAC Hz VAC dB(A) Bel(A) / Watts rpm °C Hours Hours

nominal 40 23 31 4,2 tbd 2 050* ➅


AC 100 MR* 115/230 50-60 85...265 -10...+55 70 000 / 50 000
boost 62 36 38 4,7 tbd 3 150* ➇
nominal 53 31 33 4,4 2,8 2 680 ➆
AC 100 NR-017 115/230 50-60 85...265 -10...+55 70 000 / 50 000
boost 66 39 40 5,0 3,5 3 300 ➈
Subject to alterations

* on request

Impeller Type Boost off, Boost off, Boost on


Jumper low Jumper high
high flow AC 100 MR 1 250 2 050 3 150
high flow AC 100 NR 2 200* 2 750 3 500
high pressure AC 100 MR* 1 250* 2 050* 3 150*
high pressure AC 100 NR-017 2 180 2 680 3 300

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions
2016-01

200
Information
Highest energy efficiency: 0.03 - 0.045 W/m3/h free air (Specific fan power).
Boost speed setting: 2 speed settings possible via boost function.
Vibration isolation: Reduced transmission of vibrations from motor to

DC axial fans
housing.
Intelligence: Speed settings and control outputs optional.

DC centrifugal fans
Connection

Example 1: Example 2:
Continuous operation at Nominal speed via light

DC fans - specials
nominal speed boost switch, separate boost
speed via light switch. switch.

N SL N SL

L L

ACmaxx / EC fans
Example 3: Example 4:
Simple connection, Simple connection, boost
nominal speed speed without switching.
without switching.

N N

AC axial fans
Jumper Jumper L L
Low High

AC centrifugal fans
Scope of delivery
Accessories
Representatives
2016-01

201
2016-01

202
AC axial fans

AC axial fans
AC axial fan overview

203
206
205

2016-01

Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans DC axial fans Information
AC axial fans

Technical information

Product line Bearings


The renowned ebm-papst AC fans are used when DC voltage is not AC fans with sleeve bearings are powered by Class E insulated motors.
available. The AC range of fans is based on experience gained from Fans with ball bearings are equipped with Class B, E or F insulated
decades of development activity, millions of units in series production motors.
and competence in innovation of a world-wide technological leader.
Degree of protection
A wide range of fans for AC operation is presented in this catalogue. In All fans are equipped with degree of protection IP 20 as standard.
addition to complete device fans, you will also find fans without external IP 54 / IP 68 and further degrees of protection are available on request.
housing, providing a particularly economical advantage when the air duct
can be integrated in the respective device. AC voltage
The line of AC fans for Euro voltage according
Variety of sizes to IEC 60038 (230 V + 6 %, -10 %) is basically also available for 115 V.
AC fans are available in a variety of sizes with either air exhaust or air
intake over struts. Silent running models with sleeve bearings. Frequencies
Electrical connection with plug connection or external leads are available. AC fans can be operated at frequencies of 50 Hz or 60 Hz. However, their
technical data then changes accordingly.
Shaded-pole or capacitor motors
Fan drives by shaded-pole or capacitor motors, most of which incorporate Capacitor
the world-famous ebm-papst external rotor principle: The fan blades are Fans driven by capacitor external motors
directly attached to the external rotor of the external rotor motor, thus provide particularly high operating efficiency. Generally, the required
combining both high performance and profitability. operating capacitor is already integrated in the fan housing.

Flat built AC fans Overloading


ebm-papst also has particularly flat built AC fans with internal rotor motor. Almost all AC fans are protected against overloading (e.g. due to locked
Their advantage: quick start to full speed. A plastic impeller and the both rotor) the drive motors are either impedance protected (marked
smaller and lighter internal rotor motor lead to a lower moment of inertia. “Impedance protected”, and/or “Z.P.”) or are equipped with a thermal
switch (marked “Thermally protected” or “Th.P.”). The model designation
of these fans ends with “S”.
2016-01

204
Information
Axial fans for AC operation

DC axial fans
Overview of air performance
Dimension

Air flow
Series

Page
mm m3/h 10 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 3000

DC centrifugal fans
c 80 x 38 8000 N 30...61 206
Ø 76 x 37 8000 TV 24...47 207
c 92 x 25 3900 31...70 208
c 92 x 38 3000 49...89 209
c 119 x 25 9900 84...135 210
c 119 x 38 4000 N 80...180 211
c 119 x 38 4000 Z 100...180 212
Ø 108 x 37 4600 TZ 125...140 213
c 127 x 38 5900 150...206 129 214

DC fans - specials
c 135 x 38 5600 235...270 215
150 x 172 x 38 7000 320...380 216
Ø 150 x 55 7800 325...380 217
Ø 150 x 55 7400 380...425 218
Ø 172 x 51 6000 375...500 219
c 225 x 80 W2E 200 880...1030 220
c 280 x 80 W2E 250 1865 222
Ø 200 K2E 200 765...840 224
Ø 200 K2E 200 765...850 226

ACmaxx / EC fans
Ø 200 K2D 200 780...880 228
Subject to alterations

Overview of technically feasible designs


n

tion
ectio
s/
bear earing

rotec
prot
SA

nal

AC axial fans
ings
ball sleeve b
n

UL, C

fog p
d sig
ensio

= 54
idity

IP 68

Page
Hum
Spee
c

IP >
,
Dim

Salt
Sinte
VDE

Axial fan
mm Series OPTIONAL p.
c 80 x 38 8000 N ja / – • • • • 206
Ø 76 x 37 8000 TV ja / – • • • • 207
c 92 x 25 3900 ja / – • – – – 208
c 92 x 38 3000 ja / – • • • • 209
AC centrifugal fans
c 119 x 25 9900 ja / – • – – – 210
c 119 x 38 4000 N ja / • • • • • 211
c 119 x 38 4000 Z ja / • • • • • 212
Ø 108 x 37 4600 TZ ja / – • • • • 213
c 127 x 38 5900 ja / – • – – – 214
c 135 x 38 5600 ja – • • – • 215
150 x 172 x 38 7000 ja – – – – – 216
Ø 150 x 55 7800 ja • – – – – 217
Ø 150 x 55 7400 ja – – – – – 218
Accessories

Ø 172 x 51 6000 ja – – – – – 219


Subject to alterations

• available – not yet available Sleeve bearings Ball bearings


Representatives
2016-01

205
max. 61 m /h 3
AC axial fans
 80 x 38 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: Painted sheet steel (See page 12)
– Direction of air flow: Exhaust over struts - Humidity protection
– Direction of rotation: Clockwise, seen on rotor - Salt fog protection
– Connection: Via 2 single wires - Degree of protection: IP 54 / IP 68
grounding lug for M4 x 8
– Mass: 490 g
– Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 188.

Sintec sleeve bearings


Sound pressure level
Series 8000 N

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours Hours

8880 N 30 17,7 230 50 18 3,3 9,0 1 750 -10...+80 60 000 / 25 000 ➀


8850 N 37 21,8 230 50 24 3,9 12,5 2 150 -10...+70 52 500 / 25 000 ➁
8550 N 50 29,4 230 50 30 4,4 12,0 2 700 -10...+70 52 500 / 25 000 ➂
8556 N 50 29,4 230 50 31 4,5 12,0 2 800 -40...+90 52 500 / 15 000 ➂
8830 N 36 21,2 115 60 21 3,7 8,0 1 950 -10...+80 62 500 / 25 000 ➃
8800 N 47 27,7 115 60 28 4,3 11,0 2 500 -10...+70 55 000 / 27 500 ➄
8500 N 61 35,9 115 60 34 4,8 11,0 3 200 -10...+75 55 000 / 25 000 ➅
8506 N 61 35,9 115 60 35 5,0 11,0 3 300 -40...+95 55 000 / 15 000 ➅
Subject to alterations

Fan type Length “L” Lead wires


8880 N 8830 N 8800 N 8550 N 8500 N 310 mm long AWG 18, TR 64
8556 N 8506 N 310 mm long AWG 22
8850 N 440 mm long AWG 18, TR 64

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
tin-pla
values have to be checked and reviewed once installed or ted
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

206 from p. 242


Information
max. 47 m /h3
AC axial fans
Ø 76 x 37 mm

– Material: Impeller: Die-cast aluminium – Possible special versions:


Mounting bracket: Metal (See page 12)
– Direction of air flow: Exhaust over mounting bracket - Humidity protection

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Salt fog protection
– Connection: Via 2 single wires - Degree of protection: IP 54 / IP 68
– Mass: 370 g

DC centrifugal fans
Sintec sleeve bearings
Series 8000 TV Sound pressure level

Temperature range
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Nominal data

DC fans - specials
Type m3/h cfm VAC Hz dB(A) / Watts rpm °C Hours Hours

8880 TV 24 14,1 230 50 15 9,0 1 650 -10...+80 60 000 / 25 000


8850 TV 31 18,2 230 50 20 12,0 2 100 -10...+70 52 500 / 25 000
8550 TV 40 23,5 230 50 27 12,0 2 650 -10...+70 52 500 / 25 000
8556 TV 40 23,5 230 50 28 12,0 2 750 -40...+90 52 500 / 15 000

ACmaxx / EC fans
8830 TV 27 15,9 115 60 18 8,0 1 850 -10...+80 62 500 / 25 000
8800 TV 36 21,2 115 60 24 11,0 2 450 -10...+70 55 000 / 27 500
8500 TV 47 27,7 115 60 32 11,0 3 150 -10...+75 55 000 / 25 000
8506 TV 47 27,7 115 60 33 11,0 3 250 -40...+95 55 000 / 15 000
Subject to alterations

The air flow and noise level of fans without external Fan type Length “L” Lead wires
housing depends on the installation conditions. The

AC axial fans
8880 TV 8850 TV 8830 TV 8800 TV 325 mm long AWG 18, TR 64
stated air flow and noise has been measured with an
orifice 76.5 mm Ø at a distance of approx. 17 mm from 8550 TV 8500 TV 325 mm long AWG 18, TR 64
the mounting bracket. Under exceptionally favourable 8556 TV 8506 TV 325 mm long AWG 18
mounting conditions, the air flow of fan series 8000 N
is achievable. The noise in the optimal operating range
can only be measured for these fans in a specific
application.

AC centrifugal fans

10
3,7 + 0,15

37 +1
3 R4
Accessories
0,3

101 + 0,2
ø75,8
325 +10
6 +1

Representatives

tin-plated
90°
2016-01

207
max. 70 m /h 3
AC axial fans
 92 x 25 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: Mineral-reinforced (See page 12)
plastic PA - Humidity protection
– Direction of air flow: Exhaust over struts
– Direction of rotation: Counter-clockwise, seen
on rotor
– Connection: Via 2 flat plugs 2,8 x 0,5 mm
grounding lug for M4
– Mass: 280 g
– Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 189.

Sintec sleeve bearings


Sound pressure level
Series 3900

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours Hours

3950 L 31 18,2 230 50 24 3,8 6,0 1 550 -10...+80 70 000 / 27 500 ➀


3956 L 31 18,2 230 50 24 3,8 6,0 1 550 -40...+80 70 000 / 27 500 ➀
3950 M 45 26,5 230 50 29 4,2 6,0 2 150 -10...+80 70 000 / 27 500 ➁
3956 M 45 26,5 230 50 29 4,2 6,0 2 150 -40...+80 70 000 / 27 500 ➁
3950 59 34,7 230 50 35 4,7 11,0 2 650 -20...+80 55 000 / 20 000 ➂
3956 59 34,7 230 50 35 4,7 11,0 2 650 -40...+80 55 000 / 20 000 ➂
3900 L 39 23,0 115 60 27 4,0 5,0 1 850 -10...+80 70 000 / 27 500 ➃
3906 L 39 23,0 115 60 27 4,0 5,0 1 850 -40...+80 70 000 / 27 500 ➃
3900 M 53 31,2 115 60 34 4,6 5,0 2 600 -10...+80 70 000 / 27 500 ➄
3906 M 53 31,2 115 60 34 4,6 5,0 2 600 -40...+80 70 000 / 27 500 ➄
3900 70 41,2 115 60 40 5,1 9,0 3 150 -20...+80 60 000 / 22 500 ➅
3906 70 41,2 115 60 40 5,1 9,0 3 150 -40...+80 60 000 / 22 500 ➅
Subject to alterations

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles Connection cables


2016-01

208 from p. 242 p. 255


Information
max. 89 m /h 3
AC axial fans
 92 x 38 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: Painted sheet steel (See page 12)
– Direction of air flow: Exhaust over struts - Humidity protection

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Salt fog protection
– Connection: Via 2 single wires - Degree of protection: IP 54 / IP 68
grounding lug for M4 x 8
– Mass: 420 g
– Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 189.

DC centrifugal fans
Sintec sleeve bearings
Series 3000 Sound pressure level

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours Hours

3850 49 28,8 230 50 24 3,7 9,0 1 750 -10...+75 60 000 / 27 500 ➀


3856 54 31,8 230 50 26 3,9 9,0 1 950 -40...+90 60 000 / 20 000 ➁
3550 67 39,4 230 50 32 4,4 8,5 2 300 -10...+80 60 000 / 25 000 ➂
3556 67 39,4 230 50 33 4,5 8,5 2 400 -40...+90 60 000 / 20 000 ➂

ACmaxx / EC fans
3650 75 44,1 230 50 36 4,8 12,0 2 650 -10...+55 52 500 / 37 500 ➃
3656 75 44,1 230 50 37 4,9 12,0 2 700 -40...+75 52 500 / 22 500 ➃
3800 54 31,8 115 60 26 3,9 8,0 1 900 -10...+80 62 500 / 25 000 ➄
3806 60 35,3 115 60 29 4,2 8,0 2 150 -40...+95 62 500 / 17 500 ➅
3500 73 43,0 115 60 35 4,6 8,0 2 500 -10...+80 62 500 / 25 000 ➆
3506 73 43,0 115 60 36 4,7 8,0 2 600 -40...+95 62 500 / 17 500 ➆
3600 89 52,4 115 60 41 5,1 11,0 3 100 -10...+65 55 000 / 30 000 ➇

AC axial fans
3606 89 52,4 115 60 42 5,2 11,0 3 200 -40...+75 55 000 / 25 000 ➇
Subject to alterations

Fan type Length “L” Lead wires


With sleeve bearings 310 mm long AWG 18, TR 64
With ball bearings 310 mm long AWG 18
AC centrifugal fans
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the tin-pla
values have to be checked and reviewed once installed or ted
Representatives

fitted. For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
209
max. 135 m /h 3
AC axial fans
 119 x 25 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: Mineral-reinforced (See page 12)
plastic PA - Humidity protection
– Direction of air flow: Exhaust over struts
– Direction of rotation: Counter-clockwise, seen
on rotor
– Connection: Via 2 flat plugs 2,8 x 0,5 mm
grounding lug for M4
– Mass: 320 g
– Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 192.

Sintec sleeve bearings


Sound pressure level
Series 9900

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours Hours

9956 L 84 49,4 230 50 29 4,4 9,5 1 850 -40...+80 57 500 / 22 500 ➀


9956 M 104 61,2 230 50 35 4,7 10,0 2 250 -40...+80 57 500 / 22 500 ➁
9950 117 68,9 230 50 37 5,0 14,0 2 450 -20...+70 47 500 / 22 500 ➂
9956 117 68,9 230 50 37 5,0 14,0 2 450 -40...+70 47 500 / 22 500 ➂
9906 L 100 58,9 115 60 34 4,6 8,0 2 100 -40...+80 62 500 / 25 000 ➃
9906 M 111 65,3 115 60 37 5,0 8,0 2 450 -40...+80 62 500 / 25 000 ➄
9900 135 79,5 115 60 42 5,4 12,0 2 850 -20...+70 52 500 / 25 000 ➅
9906 135 79,5 115 60 42 5,4 12,0 2 850 -40...+70 52 500 / 25 000 ➅
Subject to alterations

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles Connection cables


2016-01

210 from p. 242 p. 255


Information
max. 180 m /h 3
AC axial fans
 119 x 38 mm

– Material: Housing: Die-cast aluminium – Optionally available:


Impeller: Painted sheet steel Variants with strengthened mounting
– Direction of air flow: Intake over struts flanges and customizable single

DC axial fans
Types 4890 N and 4840 N strands
exhaust over struts
– Direction of rotation: Clockwise, seen on rotor – Possible special versions:
– Connection: Via 2 flat plugs 2,8 x 0,5 mm (See page 12)
grounding lug for M4 - Speed signal
– Mass: 550 g - Humidity protection
– Note: - Salt fog protection
Please note our new ACmaxx series. With identical - Degree of protection: IP 54 / IP 68

DC centrifugal fans
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 192.

Sintec sleeve bearings


Series 4000 N Sound pressure level

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours Hours

4890 N 80 47 230 50 25 4,0 11,0 1 550 -10...+70 55 000 / 27 500 ➀


4850 N* 100 59 230 50 32 4,4 10,0 1 800 -10...+70 57 500 / 27 500 ➁
4580 N* 123 72 230 50 41 5,2 18,0 2 350 -10...+55 40 000 / 27 500 ➂
4550 N* 145 85 230 50 44 5,4 16,5 2 550 -10...+55 42 500 / 30 000 ➃

ACmaxx / EC fans
4650 N 160 94 230 50 46 5,4 19,0 2 650 -10...+55 37 500 / 27 500 ➄
4656 N 160 94 230 50 47 5,5 19,0 2 650 -40...+85 37 500 / 15 000 ➄
4840 N 85 50 115 60 26 4,1 10,0 1 650 -10...+75 57 500 / 25 000 ➅
4800 N* 97 57 115 60 32 4,3 9,0 1 750 -10...+75 60 000 / 27 500 ➆
4530 N* 151 89 115 60 45 5,4 16,0 2 700 -10...+65 42 500 / 25 000 ➇
4500 N* 169 100 115 60 48 5,7 15,0 3 000 -10...+65 47 500 / 25 000 ➈
4600 N 180 106 115 60 50 5,7 18,0 3 100 -10...+60 40 000 / 25 000 ➉

AC axial fans
4606 N 180 106 115 60 51 5,8 18,0 3 100 -40...+90 40 000 / 15 000 ➉
Subject to alterations

* Fan with 3 blades.

AC centrifugal fans
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
Representatives

fitted. For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles Connection cables


2016-01

from p. 242 p. 255


211
max. 180 m /h 3
AC axial fans
 119 x 38 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: Painted sheet steel (See page 12)
– Direction of air flow: Exhaust over struts - Speed signal
– Direction of rotation: Clockwise, seen on rotor - Humidity protection
– Connection: Via 2 flat plugs 2,8 x 0,5 mm - Salt fog protection
grounding lug for M4 x 8 - Degree of protection: IP 54 / IP 68
– Mass: 540 g
– Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 192.

Sintec sleeve bearings


Sound pressure level
Series 4000 Z

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours Hours

4850 Z 100 59 230 50 26 4,0 13,0 1 700 -10...+65 50 000 / 27 500 ➀


4856 Z 100 59 230 50 26 4,0 13,0 1 700 -40...+75 50 000 / 20 000 ➀
4580 Z 115 68 230 50 30 4,3 13,0 1 900 -10...+65 50 000 / 27 500 ➁
4586 Z 115 68 230 50 30 4,3 13,0 1 900 -40...+75 50 000 / 20 000 ➁
4650 Z 160 94 230 50 40 5,3 19,0 2 650 -10...+50 37 500 / 30 000 ➂
4656 Z 160 94 230 50 40 5,3 19,0 2 650 -40...+75 37 500 / 17 500 ➂
4800 Z 105 62 115 60 28 4,1 12,0 1 800 -10...+70 52 500 / 25 000 ➃
4806 Z 105 62 115 60 28 4,1 12,0 1 800 -40...+75 52 500 / 17 500 ➃
4530 Z 120 71 115 60 32 4,4 12,0 2 000 -10...+70 52 500 / 25 000 ➄
4536 Z 120 71 115 60 32 4,4 12,0 2 000 -40...+75 52 500 / 17 500 ➄
4600 Z 180 106 115 60 45 5,6 18,0 3 100 -10...+60 40 000 / 25 000 ➅
4606 Z 180 106 115 60 45 5,6 18,0 3 100 -40...+85 40 000 / 15 000 ➅
Subject to alterations

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles Connection cables


2016-01

212 from p. 242 p. 255


Information
max. 140 m /h 3
AC axial fans
Ø 108 x 37 mm

– Material: Impeller: Die-cast aluminium – Possible special versions:


Mounting bracket: Metal (See page 12)
– Direction of air flow: Exhaust over mounting bracket - Humidity protection

DC axial fans
– Direction of rotation: Clockwise, seen on rotor - Salt fog protection
– Connection: Via 2 single wires - Degree of protection: IP 54 / IP 68
– Mass: 430 g

DC centrifugal fans
Sintec sleeve bearings
Series 4600 TZ Sound pressure level

Temperature range
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Nominal data

DC fans - specials
Type m3/h cfm VAC Hz dB(A) / Watts rpm °C Hours Hours

4650 TZ 125 73,6 230 50 42 19,0 2 600 -10...+50 37 500 / 30 000


4656 TZ 125 73,6 230 50 42 19,0 2 600 -40...+65 37 500 / 20 000

4600 TZ 140 82,4 115 60 45 18,0 2 950 -10...+50 40 000 / 32 500


4606 TZ 140 82,4 115 60 45 18,0 2 950 -40...+75 40 000 / 17 500

ACmaxx / EC fans
Subject to alterations

Fan type Lead wires


The air flow and noise level of fans without external
4650 TZ 4600 TZ AWG 22, TR 32
housing depends on the installation conditions. The
stated air flow and noise has been measured with an 4656 TZ 4606 TZ AWG 18
orifice 109 mm Ø at a distance of approx. 17 mm from
the mounting bracket. Under exceptionally favourable
mounting conditions, the air flow of fan series 4000 Z

AC axial fans
is achievable. The noise in the optimal operating range
can only be measured for these fans in a specific
application.

AC centrifugal fans

16 37 + 1
3
4,3 + 0,15
R4

0,5 + 0,3
Accessories
ø108 + 0,3
148,2 + 0,2

375 +10
6 +1

tin-plated
Representatives

90°
2016-01

213
max. 206 m /h 3
AC axial fans
 127 x 38 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: GRP1) (PA) (See page 12)
– Direction of air flow: Exhaust over struts - Humidity protection
– Direction of rotation: Counter-clockwise, seen
on rotor
– Connection: Via 2 flat plugs 2,8 x 0,8 mm
grounding lug for M4 x 6
– Mass: 570 g

1) Fibreglass-reinforced plastic

Sintec sleeve bearings


Sound pressure level
Series 5900

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours Hours

5988 150 88 230 50 37 4,9 13,0 2 250 -30...+55 35 000 / 20 000 ➀


5950 180 106 230 50 43 5,4 18,0 2 700 -20...+50 40 000 / 32 500 ➂
5958 180 106 230 50 44 5,5 18,0 2 750 -30...+60 40 000 / 25 000 ➂
5938 162 95 115 60 40 4,9 12,0 2 500 -30...+55 35 000 / 20 000 ➁
5900 206 121 115 60 46 5,7 17,0 3 050 -20...+55 42 500 / 30 000 ➃
5908 206 121 115 60 47 5,8 17,0 3 100 -30...+75 42 500 / 20 000 ➃
Subject to alterations

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles Connection cables


2016-01

214 from p. 242 p. 255


Information
max. 270 m /h 3
AC axial fans
 135 x 38 mm

– Material: Housing: Die-cast aluminium – Possible special versions:


Impeller: Painted sheet steel (See page 12)
– Direction of air flow: Exhaust over struts - Humidity protection

DC axial fans
– Direction of rotation: Counter-clockwise, seen - Salt fog protection
on rotor - Degree of protection: IP 54
– Connection: Via 2 flat plugs 2,8 x 0,5 mm
grounding lug for M4 x 8
– Mass: 800 g

DC centrifugal fans
Sintec sleeve bearings
Series 5600 Sound pressure level

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours Hours

5656 S 235 138 230 50 46 5,9 30,0 2 700 -35...+70 45 000 / 20 000 ➀
5606 S 270 159 115 60 50 6,2 26,0 3 100 -35...+80 47 500 / 20 000 ➁
Subject to alterations

ACmaxx / EC fans
AC axial fans
AC centrifugal fans
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
Representatives

fitted. For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles Connection cables


2016-01

from p. 242 p. 255


215
max. 380 m /h 3
AC axial fans
150 x 172 x 38 mm

– Material: Housing: Die-cast aluminium


Impeller: Painted sheet steel
– Direction of air flow: Exhaust over struts
– Direction of rotation: Counter-clockwise, seen
on rotor
– Connection: Via 2 flat plugs 2,8 x 0,5 mm
grounding lug for M4 x 8
– Mass: 900 g
– Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency.
See page 194, 196, 198.

Sintec sleeve bearings


Sound pressure level
Series 7000

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours Hours

7056 ES 320 188 230 50 51 6,4 27,0 2 800 -25...+55 60 000 / 32 000 ➀
7006 ES 380 224 115 60 56 6,8 28,0 3 350 -25...+65 55 000 / 18 000 ➁
Subject to alterations

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles Connection cables


2016-01

216 from p. 242 p. 255


Information
max. 380 m /h 3
AC axial fans
Ø 150 x 55 mm

– Material: Housing: Die-cast aluminium


Impeller: Painted sheet steel
– Direction of air flow: Exhaust over struts

DC axial fans
– Direction of rotation: Counter-clockwise, seen
on rotor
– Connection: Via 2 single wires, wire
ends with brass lead tips
grounding lug for M4 x 8
– Mass: 1,1 kg
– Note:
Please note our new ACmaxx series. With identical

DC centrifugal fans
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 194.

Sintec sleeve bearings


Series 7800 Sound pressure level

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours Hours

7855 ES 325 191 230 50 49 6,0 45,0 2 800 -25...+50 60 000 / 47 500 ➀
7856 ES 325 191 230 50 49 6,0 45,0 2 800 -25...+70 60 000 / 30 000 ➀
7805 ES 380 224 115 60 53 6,4 38,0 3 250 -25...+70 60 000 / 47 500 ➁
7806 ES 380 224 115 60 53 6,4 38,0 3 250 -25...+90 60 000 / 15 000 ➁

ACmaxx / EC fans
Subject to alterations

AC axial fans
AC centrifugal fans
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
Representatives

fitted. For detailed information see tin-pla


http://www.ebmpapst.com/general conditions ted

Guard grilles
2016-01

from p. 242
217
max. 425 m /h 3
AC axial fans
Ø 150 x 55 mm

– Material: Housing: Die-cast aluminium


Impeller: Painted sheet steel
– Direction of air flow: Intake over struts
– Direction of rotation: Counter-clockwise, seen
on rotor
– Connection: Via 2 single wires, wire
ends with brass lead tips
grounding lug for M4 x 8
– Mass: 1,1 kg
– Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series
achieves higher energy efficiency. See page 194.

Sintec sleeve bearings


Sound pressure level
Series 7400

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours Hours

7450 ES 380 224 230 50 60 6,8 47,0 2 700 -25...+50 63 000 / 50 000 ➀
7400 ES 425 250 115 60 62 6,9 46,0 3 050 -25...+70 50 000 / 24 000 ➁
Subject to alterations

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis. tin-pla
The acoustic values are only valid for the described measure- ted
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

218 from p. 242


Information
max. 500 m /h 3
AC axial fans
Ø 172 x 51 mm

– Material: Housing: Die-cast aluminium


Impeller: Painted sheet steel
– Direction of air flow: Exhaust over struts

DC axial fans
– Direction of rotation: Counter-clockwise, seen
on rotor
– Connection: Via 2 flat plugs 2,8 x 0,5 mm
grounding lug for M4 x 6
– Mass: 1,0 kg
– Note:
Please note our new ACmaxx series. With identical
mounting dimensions and voltages, this series

DC centrifugal fans
achieves higher energy efficiency. See page 196,198.

Sintec sleeve bearings


Series 6000 Sound pressure level

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VAC Hz dB(A) Bel(A) / Watts rpm °C Hours Hours

6058 ES 375 221 230 50 55 5,9 24,0 2 800 -25...+70 62 000 / 31 000 ➀
6078 ES 420 247 230 50 54 6,3 26,0 2 800 -25...+60 62 000 / 39 000 ➁
6008 ES 440 259 115 60 60 6,4 26,0 3 300 -25...+70 57 000 / 28 000 ➂
6028 ES 500 284 115 60 58 6,7 29,0 3 300 -25...+75 57 000 / 22 000 ➃

ACmaxx / EC fans
Subject to alterations

AC axial fans
AC centrifugal fans
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
Representatives

fitted. For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
219
max. 1 000 m /h 3
AC axial fans
 225 x 80 mm

– Material: Housing: Die-cast-aluminium


Impeller: Sheet steel, coated in black
Rotor: Coated in black
– Number of blades: 7
– Direction of air flow: "V"
– Direction of rotation: Counter-clockwise, seen on rotor
– Degree of protection: IP 44, depending on installation and position
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Electrical connection
Max. back-pressure
Sound power level

Perm. amb. temp.


Nominal voltage

Input current
Speed / rpm

Input power
Frequency

Capacitor
Air flow
Curve

Nominal data

Mass
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg

A 1~115 50 880 2 550 64 0,58 5,0/220 --- 80 -25...+60 2,0


W2E 200-HK86-01 M2E 068-BF p. 263 / A1)
B
1~115 60 1 000 2 800 80 0,70 5,0/220 --- 95 -25...+65 2,0
C 1~230 50 880 2 550 64 0,29 1,5/450 --- 80 -25...+60 2,1
W2E 200-HK38-01 M2E 068-BF p. 263 / A1)
D
1~230 60 1 000 2 800 80 0,35 1,5/450 --- 95 -25...+65 2,1
Subject to alterations

n Ped I L WA
in wg
Pa

Curves: rpm W A dB(A)


B D

A 1 2 640 56 0,56 ---


100
0.4

A 2 2 595 58 0,57 ---


A 3 2 550 61 0,58 ---
A 4 2 480 64 0,60 ---
80 A C
B 1 2 980 67 0,58 ---
B 2 2 880 71 0,62 ---
B 3 2 790 75 0,65 ---
60 B 4 2 660 80 0,69 ---
C 1 2 630 60 0,30 ---
0.2

C 2 2 585 64 0,31 ---


40 C 3 2 530 66 0,31 ---
B 4 2 480 69 0,32 ---
D 1 3 000 70 0,31 ---
20 D 2 2 935 73 0,32 ---
D 3 2 850 77 0,34 ---
D 4 2 705 83 0,36 ---

0 100 200 300 400 500 cfm


Pfs

qv 200 400 600 800 m³/h

Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise
levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment
conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have
to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions
2016-01

220
Information
– Motor protection: TOP wired internally
– Touch current: < 0,75 mA acc. to IEC 60990 (test circuit, illustration 4)
– Cable exit: Variabel

DC axial fans
– Electrical connection Via terminal strips (operating capacitor connected)
– Protection class: I (if customer has provided connection for protective earth)
– Product conforming
to standards: EN 60335-1, CE
– Approvals: A B EAC, UL 507, VDE, CSA C22.2 Nr. 113, CCC

C D EAC, UL 2111, VDE, CSA C22.2 Nr. 113, CCC

DC centrifugal fans
DC fans - specials
ACmaxx / EC fans
"V" ›

AC axial fans
5
22

AC centrifugal fans

N L

PE N L
Accessories
Ø4.5 +0.2
(8x)

Ø240 7 7
Ø260 80 ±0.3
Representatives

Guard grilles Connection cables


2016-01

p. 245 p. 263
221
max. 1 880 m /h 3
AC axial fans
 225 x 80 mm

– Material: Housing: Die-cast-aluminium


Impeller: Plastic PP
Rotor: Coated in black
– Number of blades: 7
– Direction of air flow: "V"
– Direction of rotation: Counter-clockwise, seen on rotor
– Degree of protection: IP 44, depending on installation and position
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Electrical connection
Max. back-pressure
Max. Input current(1)
Max. Input power(1)

Sound power level

Perm. amb. temp.


Nominal voltage

Speed / rpm(1)
Frequency

Capacitor
Air flow
Curve

Nominal data

Mass
Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg

A 1~115 50 1 740 2 375 125 1,10 12/320 70 100 -25...+50 2,7


W2E 250-HP08-01 M2E 068-CF p. 263 / A3)
B
1~115 60 1 880 2 350 165 1,45 12/320 72 110 -25...+45 2,7
C 1~230 50 1 695 2 320 125 0,55 3,0/400 70 100 -25...+60 2,7
W2E 250-HP06-01 M2E 068-CF p. 263 / A3)
D
1~230 60 1 840 2 300 160 0,71 3,0/400 71 110 -25...+50 2,7
Subject to alterations (1) Nominal data in operating point with maximum load and 115/230 VAC

n Ped I L WA
in wg
Pa

Curves: rpm W A dB(A)

A 1 2 580 108 0,96 70


100
0.4

A 2 2 510 115 1,02 69


B D A 3 2 455 121 1,06 68
A C A 4 2 375 125 1,10 68
80
B 1 2 785 149 1,30 72
0.3

B 2 2 655 154 1,35 70


B 3 2 490 162 1,41 70
60 B 4 2 350 165 1,45 70
C 1 2 550 101 0,44 70
0.2

C 2 2 480 109 0,47 69


40 C 3 2 410 115 0,50 68
B 4 2 320 125 0,55 68
D 1 2 750 134 0,59 71
0.1

20 D 2 2 600 145 0,63 70


D 3 2 420 152 0,66 69
D 4 2 300 160 0,71 70

0 200 400 600 800 1000 cfm


Pfs

qv 400 800 1200 1600 m³/h

Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side noise
levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the measurment
conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the specific values have
to be checked and reviewed once installed or fitted! For detailed information see http://www.ebmpapst.com/general conditions
2016-01

222
Information
– Motor protection: TOP wired internally
– Touch current: < 0,75 mA acc. to IEC 60990 (test circuit, illustration 4)
– Cable exit: Variabel

DC axial fans
– Electrical connection Via terminal strips (operating capacitor connected)
– Protection class: I (if customer has provided connection for protective earth)
– Product conforming
to standards: EN 60335-1, CE
– Approvals: A B UL 2111, CSA C22.2 Nr. 77

C D EAC, UL 2111, CSA C22.2 Nr. 77

DC centrifugal fans
DC fans - specials
ACmaxx / EC fans
4x90°
20° 15°
4x9
0° "V" ›
+0.2 (8x)
Ø4.4

90
Ø2

AC axial fans
PE N L

"V" ›
Ø5.4+0.25

W2E 250-HP06-01
AC centrifugal fans
0
28

7 7
90
0

80±0.5
Ø2
28

Ø4.4
+0.2

Ø295
(8x)

Ø320
4x90°
20°

W2E 250-HP08-01
4x90°

Accessories
15°

PE N L
Ø5.4+0.25 (8x)

Ø295 7 7
Representatives

Ø320 80±0.5

Guard grilles Connection cables


2016-01

p. 245 p. 263
223
max. 850 m /h 3
AC diagonal module
Ø 200 mm

– Material: Housing: Plastic PA


Support bracket: Plastic PA
Impeller: Plastic PA
Rotor: Coated in black
– Number of blades: 7
– Direction of air flow: "V"
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 44, depending on installation and position
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Electrical connection
Max. back-pressure
Sound power level

Perm. amb. temp.


Nominal voltage

Input current
Speed / rpm

Input power
Frequency

Capacitor
Air flow
Curve

Mass
Nominal data

Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg

A 1~ 115 50 760 2 650 64 0,56 6,0/250 70 200 -25..+65 2,1


K2E 200-AA12 -01 M2E 068-CF p. 263 / A1)
B 1~ 115 60 830 2 910 88 0,77 6,0/250 72 240 -25..+65 2,1
Subject to alterations

n Ped I L WA
Curves: rpm W A dB(A)

50 Hz B
A 1 2 650 64 0,56 70
A 2 2610 67 0,59 68
60 Hz A 3 2 580 70 0,61 67
A
A 4 2 590 69 0,61 69
B 1 2 910 88 0,77 72
B 2 2 815 93 0,81 69
B 3 2 755 96 0,84 69
B 4 2 780 95 0,83 71

Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side
noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the
measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the
specific values have to be checked and reviewed once installed or fitted! For detailed information see
http://www.ebmpapst.com/general conditions
2016-01

224
Information
– Motor protection: TOP wired internally
– Touch current: < 0,75 mA acc. to IEC 60990 (test circuit, illustration 4)
– Cable exit: Lateral

DC axial fans
– Electrical connection Via connector
– Protection class: I (if customer has provided connection for protective earth)
– Product conforming
to standards: EN 60335-1, CE
– Approvals: UL 2111, CSA C22.2 Nr. 77

DC centrifugal fans
DC fans - specials
ACmaxx / EC fans
X

AC axial fans
Mounting dimensions

AC centrifugal fans

Coded plug system View X


Universal-Mate-N-Lok
Connector shell: AMP 350 780-1 1 = not used
3 x Pin connector: AMP 926 885-1 2 = N + condensator
Mating connector (not part of 3=L
Accessories

delivery): 4 = PE
1 2 3 4
Connector shell: AMP 350 779-4
3 x female terminal: AMP 926 884-1
Representatives

Electrical connections
2016-01

p. 263
225
max. 850 m /h 3
AC diagonal module
Ø 200 mm

– Material: Housing: Plastic PA


Support bracket: Plastic PA
Impeller: Plastic PA
Rotor: Coated in black
– Number of blades: 7
– Direction of air flow: "V"
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 44, depending on installation and position
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Electrical connection
Max. back-pressure
Sound power level

Perm. amb. temp.


Nominal voltage

Input current
Speed / rpm

Input power
Frequency

Capacitor
Air flow
Curve

Mass
Nominal data

Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg

A 1~ 230 50 765 2 650 65 0,30 2,0/400 70 200 -25..+80 2,1


K2E 200-AA52 -02 M2E 068-CF p. 263 / A1)
B 1~ 230 60 845 2 950 90 0,40 2,0/400 73 245 -25..+80 2,1
Subject to alterations

n Ped I L WA
Curves: rpm W A dB(A)

50 Hz B A 1 2 650 65 0,30 70
A 2 2 620 67 0,30 68
60 Hz A 3 2 605 68 0,30 67
A
A 4 2 610 68 0,30 69
B 1 2 950 90 0,40 73
B 2 2 865 93 0,41 70
B 3 2 820 96 0,42 69
B 4 2 840 94 0,41 71

Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side
noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the
measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the
specific values have to be checked and reviewed once installed or fitted! For detailed information see
http://www.ebmpapst.com/general conditions
2016-01

226
Information
– Motor protection: TOP wired internally
– Touch current: < 0,75 mA acc. to IEC 60990 (test circuit, illustration 4)
– Cable exit: Lateral

DC axial fans
– Electrical connection Via connector
– Protection class: I (if customer has provided connection for protective earth)
– Product conforming
to standards: EN 60335-1, CE
– Approvals: UL 2111, CSA C22.2 Nr. 77

DC centrifugal fans
DC fans - specials
ACmaxx / EC fans
X

AC axial fans
Mounting dimensions

AC centrifugal fans

Coded plug system View X


Universal-Mate-N-Lok
Connector shell: AMP 350 780-1 1 = not used
3 x Pin connector: AMP 926 885-1 2 = N + condensator
Mating connector (not part of 3=L
Accessories

delivery): 4 = PE
1 2 3 4
Connector shell: AMP 350 779-4
3 x female terminal: AMP 926 884-1
Representatives

Electrical connections
2016-01

p. 263
227
max. 880 m /h 3
AC diagonal module
Ø 200 mm

– Material: Housing: Plastic PA


Support bracket: Plastic PA
Impeller: Plastic PA
Rotor: Coated in black
– Number of blades: 7
– Direction of air flow: "V"
– Direction of rotation: Clockwise, seen on rotor
– Degree of protection: IP 44, depending on installation and position
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Electrical connection
Max. back-pressure
Sound power level

Perm. amb. temp.


Nominal voltage

Input current
Speed / rpm

Input power
Frequency

Capacitor
Air flow
Curve

Mass
Nominal data

Type Motor VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C kg

A 3~ 400 Y 50 780 2 700 65 0,15 --- 71 210 -25..+75 2,0


K2D 200-AA02 -02 M2D 068-CF p. 263 / C2)
B 3~ 400 Y 60 880 3 050 90 0,16 --- 73 260 -25..+75 2,0
Subject to alterations

n Ped I L WA
Curves: rpm W A dB(A)
B

50 Hz A 1 2 700 65 0,15 71
A 2 2 695 69 0,16 69
60 Hz A A 3 2 675 71 0,16 68
A 4 2 680 70 0,16 69
B 1 3 050 90 0,16 73
B 2 3 010 94 0,16 71
B 3 2 970 98 0,17 70
B 4 2 975 96 0,17 72

Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. Suction-side
noise levels: LWA as per ISO 13347, LpA measured at 1 m distance to fan axis. The acoustic values given are only valid under the
measurment conditions listed and may vary depending on the installation situation. With any deviation to the standard setup, the
specific values have to be checked and reviewed once installed or fitted! For detailed information see
http://www.ebmpapst.com/general conditions
2016-01

228
Information
– Motor protection: TOP wired internally
– Touch current: < 0,75 mA acc. to IEC 60990 (test circuit, illustration 4)
– Cable exit: Lateral

DC axial fans
– Electrical connection Via connector
– Protection class: I (if customer has provided connection for protective earth)
– Product conforming
to standards: EN 60335-1, CE

DC centrifugal fans
DC fans - specials
ACmaxx / EC fans
X

AC axial fans
Mounting dimensions

AC centrifugal fans

Coded plug system View X


Universal-Mate-N-Lok
Connector shell: AMP 350 780-1 1 = L3
3 x Pin connector: AMP 926 885-1 2 = L1
Mating connector (not part of 3 = L2
Accessories

delivery): 4 = PE
1 2 3 4
Connector shell: AMP 350 779-4
3 x female terminal: AMP 926 884-1
Representatives

Electrical connections
2016-01

p. 263
229
2016-01

230
AC centrifugal fans
AC centrifugal fans

AC centrifugal fan overview

231
234
233

2016-01

Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans DC axial fans Information
AC centrifugal fans

Technical information

Product line Bearings


The renowned ebm-papst AC fans are used when DC voltage is not AC fans with sleeve bearings are powered by Class E insulated motors.
available. The AC range of fans is based on experience gained from Fans with ball bearings are equipped with Class B, E or F insulated
decades of development activity, millions of units in series production motors.
and competence in innovation of a world-wide technological leader.
Degree of protection
A wide range of fans for AC operation is presented in this catalogue. In All ebm-papst fans conform to the requirements of IP 20. Fans con-
addition to complete device fans, you will also find fans without external forming to IP 54 / IP 68 and special degrees of protection are also
housing, providing a particularly economical advantage when the air duct available.
can be integrated in the respective device.
AC voltage
Variety of sizes The line of AC fans for Euro voltage according to IEC 60038 (230 V ± 10
AC fans are available in a variety of sizes with either air exhaust or air %) is basically also available for 115 V.
intake over struts. Silent running models with sleeve bearings.
Electrical connection with plug connection or external leads are available. Frequencies
AC fans can be operated at frequencies of 50 Hz or 60 Hz. However, their
Shaded-pole or capacitor motors technical data then change accordingly.
Fan drives by shaded-pole or capacitor motors, most of which incorporate
the world-famous ebm-papst external rotor principle: The fan blades are Capacitor
directly attached to the external rotor of the external rotor motor, thus Fans driven by capacitor external motors provide particularly high
combining both high performance and profitability. operating efficiency. Generally, the required operating capacitor is already
integrated in the fan housing.
Flat built AC fans
ebm-papst also has particularly flat built AC fans with internal rotor motor. Overloading
Their advantage: quick start to full speed. A plastic impeller and the both Almost all AC fans are protected against overloading (e.g. due to locked
smaller and lighter internal rotor motor lead to a lower moment of inertia. rotor) the drive motors are either impedance protected (marked
“Impedance protected”, and/or “Z.P.”) or are equipped with a thermal
switch (marked “Thermally protected” or “Th.P.”). The model designation
of these fans ends with “S”.
2016-01

232
Information
Centrifugal fans for AC operation

DC axial fans
Overview of air performance
Dimension

Air flow
Series

Page
mm m3/h 10 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 3000

DC centrifugal fans
c 121 x 37 RL 90 40...42 234
c 135 x 38 RG 90 47...54 235
c 180 x 40 RG 125 86...94 236
c 220 x 56 RG 160 202...223 237
Ø 138 x 40 RER 125 104...115 238
Ø 176 x 54 RER 160 234...274 239

Subject to alterations

DC fans - specials
Overview of technically feasible designs
n

tion
ectio
s/

ACmaxx / EC fans
bear earing

rotec
prot
CSA

nal
ings
ball sleeve b
n

fog p
d sig
ensio

= 54
idity
, UL,

IP 68

Page
Hum
Spee
c

IP >
Dim

Salt
Sinte
VDE

Centrifugal fans
mm Series OPTIONAL p.
c 121 x 37 RL 90 ja / – • • – • 234
c 135 x 38 RG 90 ja / – • • – • 235
c 180 x 40 RG 125 ja – • • – • 236
c 220 x 56 RG 160 ja – • • – • 237

AC axial fans
Ø 138 x 40 RER 125 ja – • • – • 238
Ø 176 x 54 RER 160 ja – • • – • 239
Subject to alterations

• availabe – not yet available Sleeve bearings Ball bearings

AC centrifugal fans
Accessories
Representatives
2016-01

233
max. 42 m /h 3
AC centrifugal fans
 121 x 37 mm

– Material: Spiral housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See page 12)
Housing base: Steel plate - Humidity protection
– Direction of air flow: Centrifugal: Air outlet via - Salt fog protection
window in housing - Degree of protection: IP 54
– Direction of rotation: Clockwise, seen on rotor
– Connection: Via 2 single wires; housing
base with flat plugs
6,3 x 0,8 mm for protective
earth conductor
– Highlights: forwards-curved impeller
– Mass: 680 g
1) Fibreglass-reinforced plastic

Sintec sleeve bearings


Series RL 90

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VAC Hz Bel(A) / Watts rpm °C Hours Hours

RL 90-18/50 40 23,5 230 50 5,6 20,0 2 450 -10...+50 37 500 / 30 000 ➀


RL 90-18/56 40 23,5 230 50 5,6 20,0 2 450 -30...+70 37 500 / 20 000 ➀
RL 90-18/00 42 24,7 115 60 6,0 19,5 2 550 -10...+60 37 500 / 25 000 ➁
RL 90-18/06 42 24,7 115 60 6,0 19,5 2 550 -30...+85 37 500 / 15 000 ➁
Subject to alterations

Fan type Lead wires


RL 90-18/50 RL 90-18/00 AWG 18, TR 32
RL 90-18/56 RL 90-18/06 AWG 22

Air performance measured as per: ISO 5801,


Installation category A, without accidental
contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m
distance to fan axis.
The acoustic values are only valid for the
described measurement set-up and may vary
depending on the installation situation. In case tin-plated
of any deviation to the standard setup, the
values have to be checked and reviewed once
installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions
2016-01

234
Information
max. 54 m /h 3
AC centrifugal fans
 135 x 38 mm

– Material: Spiral housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See page 12)
Housing base: Steel plate - Humidity protection

DC axial fans
– Direction of air flow: Centrifugal: Air outlet via - Salt fog protection
window in housing - Degree of protection: IP 54
– Direction of rotation: Clockwise, seen on rotor
– Connection: Via 2 single wires AWG 22
– Highlights: forwards-curved impeller
– Mass: 560 g

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings


Series RG 90

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VAC Hz Bel(A) / Watts rpm °C Hours Hours

RG 90-18/50 54 32 230 50 5,8 22,0 2 200 -30...+60 35 000 / 22 500 ➀


RG 90-18/56 54 32 230 50 5,8 22,0 2 200 -30...+60 35 000 / 22 500 ➀
RG 90-18/00 47 28 115 60 6,2 22,0 1 900 -30...+65 35 000 / 20 000 ➁
RG 90-18/06 47 28 115 60 6,2 22,0 1 900 -30...+65 35 000 / 20 000 ➁

ACmaxx / EC fans
Subject to alterations

AC axial fans
AC centrifugal fans
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
tin-pla
Sound pressure level LpA measured at 1 m distance to fan axis. ted
The acoustic values are only valid for the described measure-
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
Representatives

fitted. For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
235
max. 94 m /h 3
AC centrifugal fans
 180 x 40 mm

– Material: Spiral housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See page 12)
Housing base: Steel plate - Humidity protection
– Direction of air flow: Centrifugal: Air outlet via - Salt fog protection
window in housing - Degree of protection: IP 54
– Direction of rotation: Clockwise, seen on rotor
– Connection: Via 2 single wires AWG 22
– Highlights: backwards-curved impeller
– Mass: 850 g

1) Fibreglass-reinforced plastic

Sintec sleeve bearings


Series RG 125

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VAC Hz Bel(A) / Watts rpm °C Hours Hours

RG 125-19/56 86 51 230 50 5,8 20,0 2 550 -30...+70 37 500 / 20 000 ➀


RG 125-19/06 94 55 115 60 6,0 19,0 2 750 -30...+80 40 000 / 15 000 ➁
Subject to alterations

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure- tin-pla
ment set-up and may vary depending on the installation ted
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
fitted. For detailed information see
http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

236 from p. 242


Information
max. 223 m /h 3
AC centrifugal fans
 220 x 56 mm

– Material: Spiral housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See page 12)
Housing base: Steel plate - Humidity protection

DC axial fans
– Direction of air flow: Centrifugal: Air outlet via
window in housing
– Direction of rotation: Counter-clockwise, seen
on rotor
– Connection: Via 2 single wires AWG 18
– Highlights: backwards-curved impeller
– Mass: 1,7 kg

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings


Series RG 160

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VAC Hz Bel(A) / Watts rpm °C Hours Hours

RG 160-28/56S 202 119 230 50 6,6 47,0 2 750 -30...+70 30 000 / 15 000 ➀
RG 160-28/06S 223 131 115 60 6,9 50,0 3 050 -30...+80 27 500 / 12 500 ➁
Subject to alterations

ACmaxx / EC fans
AC axial fans
AC centrifugal fans
Accessories

Air performance measured as per: ISO 5801,


Installation category A, without accidental contact.
Noise: Total sound power level LWA ISO 103002
measured on half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values are only valid for the described measure- tin-pla
ted
ment set-up and may vary depending on the installation
situation. In case of any deviation to the standard setup, the
values have to be checked and reviewed once installed or
Representatives

fitted. For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles
2016-01

from p. 242
237
max. 115 m /h 3
AC centrifugal fans
Ø 138 x 40 mm

– Material: Spiral housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See page 12)
with steel plate reinforced - Humidity protection
– Direction of air flow: centrifugal - Salt fog protection
– Direction of rotation: Clockwise, seen on rotor - Degree of protection: IP 54
– Connection: Via 2 single wires AWG 22
– Highlights: backwards-curved impeller
– Mass: 500 g

1) Fibreglass-reinforced plastic

Sintec sleeve bearings


Series RER 125

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

Type m3/h cfm VAC Hz Bel(A) / Watts rpm °C Hours Hours

RER 125-19/56 104 61 230 50 6,2 19,0 2 600 -30...+60 37 500 / 22 500 ➀
RER 125-19/06 115 68 115 60 6,5 18,0 2 850 -30...+70 40 000 / 20 000 ➁
Subject to alterations

The air flow and noise level of fans without


external housing depend on the installation
conditions. The stated air flow and noise
levels have been measured under the
following conditions:
Centrifugal fan mounted on a
base plate 220 x 220 mm.
Cover plate 220 x 220 mm with an air inlet of
Ø 86 mm, concentric to the impeller.

Air performance measured as per: ISO 5801,


Installation category A, with ebm-papst inlet nozzle without
protection against accidental contact.
Noise: Total sound power level LWA ISO 103002 measured on
half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values given are only valid for the described
measurement set-up and may vary depending on the
installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
For detailed information see
http://www.ebmpapst.com/general conditions tin-plated

Guard grilles Inlet nozzles


2016-01

238 from p. 242 from p. 252


Information
max. 274 m /h 3
AC centrifugal fans
Ø 176 x 54 mm

– Material: Spiral housing: GRP1) (PBT) – Possible special versions:


Impeller: GRP1) (PA) (See page 12)
with steel plate reinforced - Humidity protection

DC axial fans
– Direction of air flow: centrifugal
– Direction of rotation: Counter-clockwise, seen
on rotor
– Connection: Via 2 single wires AWG 18
– Highlights: backwards-curved impeller
– Mass: 1,0 kg

DC centrifugal fans
1) Fibreglass-reinforced plastic

Sintec sleeve bearings


Series RER 160

Temperature range
Sound power level
Nominal voltage

Service life L10


Nominal speed
Ball bearings

Input power
Frequency

at T max
at 40 °C
Air flow

Air flow

Curve
Nominal data

DC fans - specials
Type m3/h cfm VAC Hz Bel(A) / Watts rpm °C Hours Hours

RER 160-28/56S 234 138 230 50 6,6 45,0 2 800 -30...+60 30 000 / 20 000 ➀
RER 160-28/06S 274 161 115 60 6,8 46,0 3 250 -30...+70 30 000 / 15 000 ➁
Subject to alterations

ACmaxx / EC fans
The air flow and noise level of fans without
external housing depend on the installation
conditions. The stated air flow and noise
levels have been measured under the

AC axial fans
following conditions:
Centrifugal fan mounted on a
base plate 260 x 260 mm.
Cover plate 260 x 260 mm with an air inlet of
Ø 100 mm, concentric to the impeller.

AC centrifugal fans

tin-plated
Accessories

Air performance measured as per: ISO 5801,


Installation category A, with ebm-papst inlet nozzle without
protection against accidental contact.
Noise: Total sound power level LWA ISO 103002 measured on
half-sphere of 2 m;
Sound pressure level LpA measured at 1 m distance to fan axis.
The acoustic values given are only valid for the described
measurement set-up and may vary depending on the
installation situation.
In case of any deviation to the standard setup, the values have
to be checked and reviewed once installed or fitted.
Representatives

For detailed information see


http://www.ebmpapst.com/general conditions

Guard grilles Inlet nozzles


2016-01

from p. 242 from p. 252


239
2016-01

240
Information
Accessories

DC axial fans
Guard grilles 242
Fan filter guard grilles 250
Inlet nozzles 252

DC centrifugal fans
Connection cables / Accessories 255
Electrical connections 258

DC fans - specials
ACmaxx / EC fans
AC axial fans
AC centrifugal fans
Everything that you need for your fan. ebm-papst provides an extensive
range of accessories for optimum fan operation: From temperature
sensing for speed-controlled fans to finger guards of all types, connecting
cable, filter, screens, spacers and assembly parts. In addition to the
accessories and assembly parts listed in this catalogue, ebm-papst also
supplies numerous special parts for fan operation. The sales experts at
ebm-papst will be happy to assist you in your enquiries concerning fan
Accessories

assembly and application.

From selection to accessories: Insist on the efficient and reliable service


provided by ebm-papst.
Representatives
2016-01

241
Guard grilles

– Material: Zinc-plated or nickel-plated steel wire


– Note: Guard grille in line with DIN EN ISO 13857 (previously EN 294).
Additional guard grilles that do not meet DIN EN ISO 13857 can be delivered
on request.
Our guard grilles are designed specifically for use with ebm-papst fans.
They combine the highest degree of safety with minimum effect on operating
noise. Please note that safety-relevant clearances cannot be guaranteed
when using guard grilles from other manufacturers.

Fan series Guard grilles Fan series Guard grilles Fan series Guard grilles
400 LZ29-1 5100 LZ25 2200 F LZ22
420 J LZ29-1 5600 LZ25 DV 4100 LZ30-4 Intake-/Outlet side
500 LZ31 5200 LZ35 DV 5200 LZ35 Intake-/Outlet side
600 LZ28-1 5300 LZ53 DV 6300 TD LZ37 Intake side
3000 LZ23-1 5900 LZ35 DV 6300 TD LZ52 Outlet side
8000 LZ32-4 / LZ22-2 7000 LZ36 DV 6400 LZ38 Intake side
9000 LZ30-4 / LZ 30 / LZ 30-3 6300 LZ37 DV 6400 LZ39 Outlet side
4000 LZ30-4 / LZ 30 / LZ 30-3 6400 LZ38 Subject to alterations

LZ29-1 Fan size 40 x 40 LZ31 Fan size 50 x 50 LZ28-1 Fan size 60 x 60

50
42 1,8

2 +0,3
50
42

5
0,
4,5


4,

30+1 4,2 +0,5


4,8 59

LZ22-2 Fan size 80 x 80 LZ32-4 Fan size 80 x 80 LZ23-1 Fan size 92 x 92

71,5 82,5
105,5 +0,5
48±1

78±1

71,5

82,5

2 + 0,3
2 + 0,3
2
0,
+

2
0,
3

3+

4,3+0,2 2,5+0,3
4,

4,

4,7+1 4,7+1
40+1 40+1
_
78,2 ±0,5 92 1
2016-01

242
Information
LZ30 Fan size 119 x 119 LZ30-3 Fan size 119 x 119 LZ30-4 Fan size 119 x 119

104,8

DC axial fans
153,5 ±1
115 ±1

104,8
3±0,25 2+0,3

DC centrifugal fans
2
0,
3+
4,
4,3+0,2 5+1 51,5 +1 4,7+1
_
119 1

LZ35 Fan size 127 x 127 LZ25 Fan size 135 x 135 LZ53 Fan size 140 x 140

124,5 + 0,2

DC fans - specials
136,5
70

ACmaxx / EC fans
5
6,45 +1

+
0,
LZ36 Fan size 150 x 172 LZ37 Fan size 172 x 51 LZ38 2 Fan size 172 x 51

AC axial fans
AC centrifugal fans

LZ39 Fan size 172 x 51 LZ52 Fan size 172 x 51 LZ22 Fan size 200 x 51
14
8,
5
199,5 + 0,5
186,5 )

Accessories
(

5 + 0,2 8,45 +1

27,5
Representatives
2016-01

243
Guard grilles

– Material: Zinc-plated or nickel-plated steel wire


– Note: Guard grille in line with DIN EN ISO 13857 (previously EN 294).
The guard grilles detailed on this page are intended specifically for the ACmaxx /
GreenTech EC compact fan ranges and are mounted on the pressure side.

Fan series Guard grilles Fan series Guard grilles


AC 8300 H LZ32-4 Intake side ACi 4400 LZ30 Intake side
AC 8300 H LZ32-7 Outlet side ACi 4400 LZ30 Outlet side
AC 3200 J LZ23-1 Intake side AC 6200 N LZ37 Intake side
AC 3200 J LZ23-6 Outlet side AC 6200 N LZ37-2 Outlet side
AC 4400 FN LZ30-4 Intake side * Outlet-side grilles on request
AC 4400 FN LZ30-9 Outlet side
AC 4300 LZ30-4 Intake side
AC 4300 LZ30-9 Outlet side

LZ30-9 Fan size 119 X 119 LZ37-2 Fan size Ø 172 X 51 LZ23-6 Fan size 92 x 92

82,5 + 0,2

104,8
162 ±0,3

63,7
89
+0,5

Ø
51,5

15
8,
104,8

2,5
2 +0,3

4,5 + 0,1
7,3
2
0,
3+
4,

51,5 +1 4,7+1
4,3 ±0,2 6 ±0,5
119 -1

LZ32-7 Fan size 80 x 80

71,5 + 0,2
0,5

61,1 + 0,25
79,8

4,5 + 0,1 6,3 + 0,3

12,9 + 0,3
2016-01

244
Information
Guard grilles

– Material: Steel wire, plastic-coated,


silver-metallic gloss

DC axial fans
DC centrifugal fans
Fan series Guard grilles Fan series Guard grilles
W3G 200 78128-2-4039 W1G 250 09418-2-4039
W3G 250 09418-2-4039

DC fans - specials
ACmaxx / EC fans
78128-2-4039 Size 200 09418-2-4039 Size 250

AC axial fans
AC centrifugal fans
Accessories
Representatives
2016-01

245
Guard grilles

– Material: Steel wire

Guard grilles for centrifugal blowers with dual inlet


Part no. Size a b c Coating

83319-2-4039 097 (1) 96,0 3,5 71,0 phosphated, plastic-coated in RAL no. 9005
09485-2-4039 097 (2) 114,0 3,5 88,0 phosphated, plastic-coated in RAL no. 9005
09500-2-4039 133 / 146 145,0 4,0 122,0 phosphated, plastic-coated in RAL no. 9005
Subject to alterations (1) for D2E097-CH (2) for D2E097-B *

– Material: Phosphated steel wire, plastic-


coated, silver-metallic gloss

Guard grilles for centrifugal blowers with dual inlet (versions with EW motor)
Part no. Size a b c d e

35000-2-4039 160 182,0 12,0 144,0 2,4 4,5


Subject to alterations
2016-01

246
Information
Guard grilles

– Material: Welded grille made of galvanised


steel, frame made of tinned sheet
iron 0.4 mm thick

DC axial fans
DC centrifugal fans
(4)
Size 160

Guard grilles for centrifugal blowers with single inlet


Part no. Size a b c

DC fans - specials
09489-2-4039 085 (3) 90,0 74,0 84,0
09490-2-4039 108 126,0 110,0 118,0
09494-2-4039 120 140,0 124,0 132,0
09492-2-4039 140 / 146 168,0 152,0 158,0
09503-2-4039 160 (4) 183,0 170,0 175,0
Subject to alterations (3) 3 drilled holes staggered by 120°

ACmaxx / EC fans
– Material: steel wire

AC axial fans
AC centrifugal fans
Guard grilles for centrifugal blowers with single inlet
Part no. Size a b c d e Coating

09603-2-4039 076 / 085 101,0 6,0 79,0 4,3 8,0 plastic coated, silver-metallic gloss
98214-2-4039 108 120,0 3,5 88,0 4,3 8,0 plastic coated, silver-metallic gloss
25028-2-4039 140 / 146 162,0 8,5 139,0 4,3 8,0 galvanised, chromatised in blue
17729-2-4039 160 175,0 3,5 139,0 4,6 7,0 galvanised, chromatised in blue
Accessories

Subject to alterations
Representatives
2016-01

247
Guard grilles

– Material: Fibreglass-reinforced plastic


– Note: Guard grille acc. to DIN EN ISO 13857 (previously EN 294).
Plastic grilles must not be used for the following models:
8200 JH3 / JH4
3200 JH3 / JH4
4100 NH5 - NH8

Guard grilles Mounting B C D E Guard grilles Mounting B C D E


LZ28-3 A3 60 -0,5
50,0 ±0,2
3,0 24 LZ30-5 A2 119 -0,5
105 ±0,2
6,5 50
LZ32-2 A1 80 -0,5
71,5 ±0,2
7,0 34 LZ30-6 A4 119-0,5 105±0,2 6,5 50
LZ32-3 A3 80 -0,5
71,5 ±0,2
7,0 34 LZ33-1 A2 127 -0,5
113,5 ±0,2
6,5 50
LZ23-2 A1 92,5 -0,5
82,5 ±0,2
6,5 46 LZ33-2 A4 127-0,5 113,5±0,2 6,5 50
Subject to alterations
LZ23-3 A3 92,5-0,5 82,5±0,2 6,5 46

LZ28-3 Size 60 x 60

LZ32-2 / LZ32-3 Size 80 x 80

LZ23-2 / LZ23-3 Size 92 x 92

LZ30-5 / LZ30-6 Size 119 x 119

LZ33-1 / LZ33-2 Size127 x 127

Only suitable for bore hole diameter


¯ 4,3 - ¯ 4,7.

LZ28-3 Fan size 60 x 60 LZ32P Fan size 80 x 80 LZ30P Fan size 119 x 119
2016-01

248
Information
Guard grilles
for compact centrifugal modules

– Material: Fibreglass-reinforced plastic PA


– Highlights: Flame protection class in line with UL 94V-0

DC axial fans
DC centrifugal fans
Fan series Guard grilles a b
RG 190 LZ46-1 133 9,0
RG 220 LZ47-1 166 8,7

DC fans - specials
RG 225 LZ48-1 158 8,7
Subject to alterations

ACmaxx / EC fans
AC axial fans
AC centrifugal fans
Accessories
Representatives
2016-01

249
Fan filter guard grilles

– Material: Filter guard LZ40 N: black, fibreglass-reinforced plastic with


inserted wire mesh LZ60.
Filter LZ60: stainless steel wire mesh
Mounting lug LZ40-1 for mounting

Fan series DC Fan series AC


4400 F AC 4300
4400 FN 9900
4300 4000 N
4400 4000 Z
4100 N Subject to alterations

LZ40N Panel LZ40-1 Mounting lug LZ60 Coarse filter


2016-01

250
Information
Fan filter guard grilles

– Material: Grille cover: polycarbonate (PC) with matt finish


Mounting plate: wire mesh with black powder coating
Filter pad: white, synthetically joined fibres

DC axial fans
– Note:
Filter guard grille suitable for fitting on axial fan ranges in the following dimensions:
60 mm, 80 mm, 92 mm, 119 mm, ø 172 mm. All filter units fit directly on the mounting
holes on the fans.
Filter guard grille consisting of 3 parts: outer grille cover, inner mounting plate and
replaceable filter pad.
The filter pad can be replaced quickly and easily via a quick release on the grille cover.
The filter pads can be replaced even while the fan is running, as protection is provided

DC centrifugal fans
by the welded wire mesh.

Protection filter Fan size A B C D Replacement filter*


FF60 60 x 60 mm 65 65 13,5 50,0 RF 60
FF80 80 x 80 mm 85 85 14,0 71,5 RF 80

DC fans - specials
FF92 92 x 92 mm 125 105 17,5 82,5 RF 92
FF119 119 x 119 mm 162 136 18,5 104,5 RF 119
FF172 ø 172 mm 226 190 19,5 162,0 RF 172
Subject to alterations
* Replacement filters only in packs of 5 pcs.

ACmaxx / EC fans
FF60 / FF80 FF92 / FF 119

Fan size: 60 x 60 mm Fan size: 92 x 92 mm


80 x 80 mm 119 x 119 mm

A C D A C D

AC axial fans
B
B

D
D

AC centrifugal fans

FF 172

Fan size: Ø 172 mm

A C D

Filter performance
The filter guard grille filters 75% of dust
Accessories

particles with a size of 5-10 microns and can


B

withstand temperatures of up to 100 °C. Filter


class G3 in line with DIN EN 779.
Flame-retardant in line with DIN 53438, class
F1. With a clean mounted filter, a reduction of
air flow of 20-30% is possible.
Representatives
2016-01

251
Inlet nozzles
for centrifugal fans

– Material: Galvanised sheet steel

Fan Vers. k m o q r1 s t u No.:


RET 97 (S) 1 116,0 80,0 10,0 0,80 10,0 108,0 3x4,5 – LZ 1000-097
RER 120 (P) 1 146,0 94,4 18,0 0,80 16,0 134,0 4x4,5 126,0 LZ 1000-120
RER 133 (P) 1 129,0 87,0 13,0 1,00 8,0 118,0 4x4,5 103,0 LZ 1000-133
RER 160 (S) 1 142,0 100,0 9,0 1,00 8,0 132,0 4x4,5 – LZ 1000-160
RER 175 / 190 (P) 1 170,0 125,5 14,0 1,25 10,0 158,0 4x4,5 146,0 LZ 1000-175
RER 220 (P) 2 252,0 155,0 21,0 0,80 22,0 – – 199,0 LZ 1000-220
RER 225 (P) 1 223,0 146,0 28,0 1,50 25,0 210,0 4x4,5 196,0 LZ 1000-225
(P) = plastic, (S) = sheet steel

Vers. 1 Vers. 2

118 45
°

4,
0 3
4 x 90°
Øk

Øu

5
Øs

242
24
r1
Øm

t 6x 5,5
q 60
°
2016-01

252
Information
Inlet nozzles
for centrifugal fans

– Material: Galvanised sheet steel


Vers. 1

DC axial fans
DC centrifugal fans
Inlet nozzles for backward curved centrifugal fans
Part no. Size(1) Vers. k m n o q r1 r2 r3 s t u

96120-2-4013 120 (P) 1 146,0 94,4 — 18,0 0,80 16,0 — — 134,0 4x4,5 126,0

DC fans - specials
Subject to alterations (1) Size with key for impeller material: (P) = plastic, (S) = sheet steel, (A) = aluminium

ACmaxx / EC fans
Vers. 1
– Material: Galvanised sheet steel

AC axial fans
Inlet nozzles for forward curved centrifugal fans
Part no. Size Vers. a b c d e f r u AC centrifugal fans

09560-2-4013 085 (1) 1 92,0 63,4 84,0 6,0 3x4,2 0,80 6,8 —
09563-2-4013 097 (1) 1 116,0 80,0 108,0 10,0 3x4,5 0,80 10,0 —
09566-2-4013 108 1 129,0 87,0 118,0 13,0 4x4,5 1,00 8,0 —
09569-2-4013 120 1 142,0 100,0 132,0 9,0 4x4,5 1,00 8,0 —
09572-2-4013 133 1 150,0 112,0 142,0 12,0 4x4,5 1,00 10,0 —
09576-2-4013 140 / 146 1 170,0 125,5 158,0 14,0 4x4,5 1,25 10,0 —
Accessories

09588-2-4013 160 1 (2) 185,0 130,0 175,0 17,0 4x4,5 0,75 12,0 —
Subject to alterations (1) 3 drilled holes staggered by 120° (2) only for 09588-2-4013
Representatives
2016-01

253
Inlet nozzles / Air filter
for centrifugal fans

Vers. 1 Vers. 2
– Material: Galvanised sheet steel

Inlet nozzles without measuring device for backward curved centrifugal fans
Part no. Size Vers. Dimensions

09576-2-4013 190 1 see corresponding product page


09609-2-4013 220 2 see corresponding product page
96358-2-4013 225 1 see corresponding product page
96359-2-4013 250 1 see corresponding product page
28000-2-4013 280 1 see corresponding product page
31000-2-4013 310 1 see corresponding product page
Subject to alterations

– Material: Steel wire / sheet steel plate, plastic coated


in RAL no. 9005, black
– Filter: Viledon filter type R: PSB / 29 OS
(according to DIN 24185)
Separation capacity: < 86 %
Efficiency: < 20 %
Dust binding capacity: 650 g/m2

Air filters for centrifugal blowers (with die-cast aluminium housing)

Part no. Size a b c d e Spare filter

95777-1-5171 108 / 120 142,0 66,0 83,0 118-132 145,0 95779-1-5171


95778-1-5171 140 / 146 / 160 185,0 74,0 91,0 158-175 185,0 95780-1-5171
Subject to alterations
2016-01

254
Information
Connection cables

– Connection cable with moulded plug connection in varying lengths.


– Wire end with core crimp sleeve, core-end sleeve or tin-plated.
– Straight or angled plug.

DC axial fans
– For all fan types with pin 2.8 / 3.0 x 0.5.

DC centrifugal fans
Plug model L1 (mm) Leads Plug Leads end Receptacle for tabs Application
2
LZ120 610 0,5 mm G C 2,8 x 0,5 AC
LZ120-4 2 000 0,5 mm2 G A 2,8 x 0,5 AC

DC fans - specials
LZ120-5 380 0,5 mm2 W B 2,8 x 0,5 DC
2
LZ120-6 610 0,5 mm W B 2,8 x 0,5 DC
LZ120-11 2 000 0,5 mm2 G A 2,8 x 0,5 DC
LZ120-16 800 0,5 mm2 G B 2,8 x 0,5 AC
2
LZ120-18 4 000 0,5 mm G A 2,8 x 0,5 AC
LZ126 1 000 0,5 mm2 G C 2,8 x 0,5 AC
LZ127 1 600 0,5 mm2 G B 2,8 x 0,5 AC

ACmaxx / EC fans
2
LZ130-1 610 0,82 mm G C 2,8 x 0,5 AC *
LZ140 610 0,73 mm2 G B 2,8 x 0,8 AC

* UL-approved

Connection cable Straight plug (G)


2±0,2
16,5

8,5 ±0,1
7,5
15
12

AC axial fans
11 10 4
22,5
31 L1

Connection cable Angled plug (W)


AC centrifugal fans
3,5 –0,25
8,5 ±0,1
16 –0,5

8
6

4
7,5 5,5 –0,25
20 +0,5 L1 8
Accessories

Cor crimp sleeve Leads end A Tin-plated Leads end B Core end sleeve Leads end C
ȯ1,5
ȯ1,5

10+5
–2

6 6
Representatives
2016-01

255
Connection leads (ESM) / Handheld Programmer

– Design: Cable conforms to UL standards,


sealed plug.
Custom-built connection leads on
request.

Jacketed cable, internal line Brass lead tips


(UL Style 2464/1061)
3 x AWG20 (approx. 0.5 mm2)

Connection leads for energy-saving motors 115/230 VAC

Part no. a

13060-4-1040 450
13061-4-1040 1500
Subject to alterations

– Easy speed programming

– Battery operated

– User-friendly navigation menu

– Protective boot with kickstand

For Energy Saving Motor (ESM) based products


Part no.

CBC 000-AF08-01
Subject to alterations

Makes quick work of programming the two ESM selectable operating speeds. Eliminates the need for a personal computer, software, power adapter
and 2nd cable. Good for production line or field service use. Automatic shut-off function for an extended battery life. Mini-USB connector for uploading
software upgrades. Batteries, programming cable and operating manual included.
2016-01

256
Information
Accessories

In addition to the accessories and assembly parts listed in this catalogue, ebm-papst also
supplies numerous special parts for fans. The sales experts at ebm-papst will be happy to
assist you in your enquiries concerning fan assembly and application.

DC axial fans
DC centrifugal fans
Fan series Accessories Fan series Accessories
8300 LZ212 / LZ260 5100 LZ210
8400 N LZ261 5600 LZ210

DC fans - specials
3400 N LZ261 5200 LZ210
9000 LZ210 5900 LZ210
4000 LZ210 7000 LZ210
4300 LZ212 / LZ260 VARIOFAN LZ370

ACmaxx / EC fans
LZ212 LZ260 / LZ261 LZ210

AC axial fans
Screw clip of stainless steel. Spacer of fibreglass reinforced plastic. For screw Screw clip of hardened steel. For mounting
For mounting fans with threaded mounting over both fan mounting flanges. fans with threaded pin 6-32 UNC and/or 3.5
pin 3.5 DIN EN ISO 1478 (7970). DIN 7970.
AC centrifugal fans

LZ370 LZ550

(2x) 0,5x45°
Ø 6,6
Ø 11

50°
(2x) Ø 4

0,5
Accessories

12 6,9 ±0,1 11±0,3

Temperature sensor for speed-controlled Rubber anti-vibration mounts


fan operation. Temperature range 30...50 °C. for fans with a hole ø of 4.3 ±0.2 mm and
flange thickness of 3 - 5.5 mm.
For a carrier plate with a hole ø of 6.5 ±0.15 mm
and plate thickness of 1 - 2 mm.
Representatives
2016-01

257
Electrical connections EC
E)
Technical features (Nominal voltage 24 / 48 VDC):
• Control input 0-10 VDC / PWM
• Tach output
• Reverse polarity and locked-rotor protection
• Motor current limitation
• Voltage-dependent derating
• Over-temperature protected electronics / motor
• Soft start

Notes on various control possibilities and their applications


Maximum ripple
± 3.5%
red

33 K 4.7 K
Lin/PWM control input
RE > 100 K
0-10 VDC / PWM
yellow
Counter

Tach output Isink max. 10 mA


Controller
U pulses per revolution
PWM
680 V
10 K white
Alarm

12 V 12 V Speed display
47 V

GND
Temperature Speed setting Speed setting Full speed Speed setting blue
control module with
PWM 1 - 50 kHz potentiometer 1 V - 10 V
50002-1-0174
50003-1-0174
100% PWM -> n=max 10 V -> n =max
approx. 10% PWM -> n=min approx. 1 V -> n = min
< 10% PWM -> n=0 < 1 V -> n = 0
safe start-up at safe start-up at
UNom - 30% as of 40% PWM UNom - 30% as of 4V Ucontr.

Customer circuit Connection Fan

Line 1
0-10 V
Tacho

PWM
GND
+

red blue white yellow

Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 + red Maximum ripple ± 3.5 % 1 Tacho white Tach output
GND blue GND 0-10 V / PWM yellow Control input
2016-01

258
Information
Electrical connections EC
G)
Technical features (Nominal voltage 24 / 48 VDC):
• Control input 0-10 VDC / PWM

DC axial fans
• Tach output
• Reverse polarity and locked-rotor protection

DC centrifugal fans
Notes on various control possibilities and their applications
Maximum ripple
± 3.5%
red

33 K 4.7 K
Lin/PWM control input
0-10 VDC / PWM

DC fans - specials
yellow
Counter

Tach output Isink max. 10 mA


Controller
U pulses per revolution
PWM
680 V
10 K white
Alarm

12 V 12 V Speed display
47 V

ACmaxx / EC fans
GND
Temperature Speed setting Speed setting Full speed Speed setting blue
control module with
PWM 1 - 10 kHz potentiometer 1 V - 10 V
50002-1-0174
50003-1-0174
100% PWM -> n=max 10 V -> n =max
approx. 10% PWM -> n=min approx. 1 V -> n = min
< 10% PWM -> n=0 < 1 V -> n = 0

start up at > 14 % start up at > 1.4 V

Customer circuit Connection Fan

AC axial fans
Line 1
0-10 V
Tacho

PWM
GND
+

red blue white yellow

Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 + red Maximum ripple ± 3.5 % 1 Tacho white Tach output:
GND blue GND 2 pulses / revolution (M1G045/M1G055) AC centrifugal fans
3 pulses / revolution (M1G074/M1G084)
0-10 V / PWM yellow Control input (Impedance 100 kV)
Accessories
Representatives
2016-01

259
Electrical connections EC
H3)
Technical features (M3G 045 / M3G 055 with 2 Speed stages):
• Speed adjustment input (230V)
• Over-temperature protected electronics / motor
• Motor current limitation
• Locked-rotor protection
• Soft start

Customer circuit Connection Fan

L AC1 P
CON10
N AC2 N
CON11
SL
CON70
PE
CON10 CON11 CON12
PE1
CON70 CON70

Line Connection Colour Assignment / function


CON10 L black Power supply 230 VAC, 50 - 60 Hz, see type plate for voltage range
CON11 N blue Neutral conductor
CON12 PE green/yellow Protective earth
CON70 SL brown Speed selection: switch open = speed 1; switch closed = speed 2
2016-01

260
Information
Electrical connections EC
H4)
Technical features (M3G 055 Speed-controlled):
• Output 10 VDC max. 1,1 mA

DC axial fans
• Tach output
• Over-temperature protected electronics / motor
• Motor current limitation
• Soft start
• Locked-rotor protection
• Control input 0-10 VDC / PWM
• Control interface with SELV potential safely disconnected from the mains

DC centrifugal fans
Customer circuit Connection Fan

max. Speed L AC1 P


speed setting L
N 3.15AT
+ 10V 0-10V/PWM AC2 N

DC fans - specials
N

PE
1-10V
PE
0-10V/PWM GND PE1
10V -> n = max
1V -> n = min
<1V -> n = 0
1 3
+10V
+ 10V
Imax=1.1mA 2 4

ACmaxx / EC fans
10V/PWM
0-10V/PWM
47k 47k

Speed Speed 1mF


GND
setting with setting with GND
PWM 1-10kHz potentiometer
15V
Tacho 3 1
+ 10V Tacho
680R
Imax=10mA 4 2

AC axial fans
ZMM47

0-10V/PWM 0-10V/PWM
10K

12V
GND GND
100% PWM -> n = max
10% PWM -> n = min
<10% PWM -> n = 0

AC centrifugal fans

Connection Colour Assignment / function


L black Power supply 230 VAC, 50 - 60 Hz, see type plate for voltage range
N blue Neutral conductor
PE green/yellow Protective earth
+10V/max.1.1mA red Voltage output +10 V / 1.1 mA, electrically isolated, not short-circuit-proof
Tacho white Tach output: Open Collector, 1 pulse per revolution, electrically isolated
Accessories

0-10V PWM yellow Control input 0 - 10 V or PWM, electrically isolated


GND blue GND - Connection for control interface
Representatives
2016-01

261
Electrical connections EC
J5)
Technical features (Nominal voltage 24 / 48 VDC):
• Control input 0-10 VDC / PWM
• Tach output
• Reverse polarity and locked-rotor protection
• Motor current limitation
• Line undervoltage detection
• Soft start

Notes on various control possibilities and their applications

max. Speed setting Speed setting with


speed potentiometer UN
1 UB
1 2 1 +24/48VDC
4.7K
1-10V
2 4 0-10VDC
10V -> n = max 2 RE>100K
1V -> n = min 2
<1V -> n = 0 10K
safe start-up at
Unom -30%
as of 4V Ucontr. 4
DUE
3
680R

DUE
39V
Speed setting with Setting of values via GND
PWM 1-10kHz temperature controller 4 GND1
Reverse
-polarity
protection
1 1
33K
P

OUT
2 T 2

50003-1-0174
N

12V
4 4
100% PWM -> n = max T<10°C -> n = 0
10% PWM -> n = min T>45°C -> n = max
<10% PWM -> n = 0
safe start-up at
Unom -30%
as of 40% PWM

Customer circuit Connection Fan

Line Connection Colour Assignment / function


1 UN +24/48 VDC red Power supply 24/48 VDC, Maximum ripple ± 3,5 %
2 0-10 VDC yellow Control input Re >100 K
3 Tach white Speed monitoring output, 3 pulses / revolution, Isink max. = 10 mA
4 GND blue Reference ground
2016-01

262
Information
Electrical connections AC
A1) / A3) / C2)

DC axial fans
A1) Single-phase capacitor motor (1~ 115/230 VAC power line)
with TOP wired internally

L PE N U1 = blue
C
U2 = black

DC centrifugal fans
Z = brown
U1 U2 Z = green/yellow

TOP

DC fans - specials
A3) Single-phase capacitor motor (1~ 115/230 VAC power line)
with TOP wired internally
C
L = blue

ACmaxx / EC fans
N = black
= green/yellow

PE N L

AC axial fans
C2) Star connection (3~ 400 VAC power line)
without TOP

U1 = black AC centrifugal fans


PE L1 L2 L3
U2 = green
V1 = blue
U1 V1 W1
V2 = white
W1 = brown
U2 V2 W2 W2 = yellow
= green/yellow
Accessories
Representatives
2016-01

263
Electrical connections AC
J7)

J7) Energy-saving motor (ESM) (1~ 115/230 VAC power line)


L1 black

Mains supply
Energy-saving
voltage blue
motor / fan
N (ESM)
Speed selection brown
L1 or N
S

S off on (L1 or N)
Speed selection n1 n2
2016-01

264
Information
ebm-papst in Germany

DC axial fans
ebm-papst Mulfingen GmbH & Co. KG ebm-papst St. Georgen GmbH & Co. KG ebm-papst Landshut GmbH
Bachmühle 2 Hermann-Papst-Straße 1 Hofmark-Aich-Straße 25
74673 Mulfingen 78112 St. Georgen 84030 Landshut
GERMANY GERMANY GERMANY
Phone +49 7938 81-0 Phone +49 7724 81-0 Phone +49 871 707-0

DC centrifugal fans
Fax +49 7938 81-110 Fax +49 7724 81-1309 Fax +49 871 707-465
[email protected] [email protected] [email protected]

Berlin Heilbronn / Heidelberg Ulm


Dipl.-Ing. (TH) Jens Duchow Dipl.-Ing. Mark Gartner M.Sc. Reinhard Sommerreißer
Händelstraße 7 Gehrweg 12 Am Germanenring 13
16341 Panketal 74199 Unterheinriet 86674 Baar / Schwaben
GERMANY GERMANY GERMANY
Phone +49 30 944149-62 Phone +49 7130 404569-1 Phone +49 8276 5899-775

DC fans - specials
Fax +49 30 944149-63 Fax +49 7130 404569-2 Fax +49 8276 5899-776
[email protected] [email protected] [email protected]
Bielefeld Kassel
Dipl.-Ing. (FH) Wolf-Jürgen Weber Dipl.-Ing. (FH) Ralph Brück Distributors
Niehausweg 13 Hoherainstraße 38 Burgdorf
33739 Bielefeld 35075 Gladenbach ETB Electronic Team
GERMANY GERMANY Beratungs- u. Vertriebs GmbH
Phone +49 5206 91732-31 Phone +49 6462 4071-10 Wundramweg 1
Fax +49 5206 91732-35 Fax +49 6462 4071-11 31303 Burgdorf
[email protected] [email protected] GERMANY

ACmaxx / EC fans
Dortmund Koblenz Phone +49 5136 97229-30
Dipl.-Ing. (FH) Hans-Joachim Pundt Winfried Schaefer Fax +49 5136 97229-39
Auf den Steinern 3 Hinter der Kirch 10 [email protected]
59519 Möhnesee-Völlinghausen 56767 Uersfeld www.etb-electronic.de
GERMANY GERMANY Frankfurt
Phone +49 2925 800-407 Phone +49 2657 16-96 R.E.D. Handelsgesellschaft mbH
Fax +49 2925 800-408 Fax +49 2657 16-76 Gutenbergstraße 3
[email protected] [email protected] 63110 Rodgau - Jügesheim
Frankfurt Munich GERMANY
Dipl.-Ing. Christian Kleffmann Dipl.-Wirt.-Ing. (FH) Jens Peter Phone +49 6106 841-0
Dr.-Hermann-Krause-Straße 23 Landsbergerstraße 14 Fax +49 6106 841-111

AC axial fans
63452 Hanau 86932 Pürgen [email protected]
GERMANY GERMANY www.red-elektromechanik.de
Phone +49 6181 1898-12 Phone +49 8196 99877-54 Frankfurt / Neu-Isenburg
Fax +49 6181 1898-13 Fax +49 8196 99877-55 Arrow Central Europe GmbH
[email protected] [email protected] Frankfurter Straße 211
Halle Nuremberg 63263 Neu-Isenburg
Dipl.-Ing. (TU) Michael Hanning Dipl.-Wirt.-Ing. (FH) Axel Resch GERMANY
Lercheneck 4 Dr.-August-Koch-Str. 1 Telefon: +49(0)6102/5030-0
AC centrifugal fans
06198 Salzatal / OT Lieskau 91639 Wolframs-Eschenbach Telefax: +49(0)6102/5030-8455
GERMANY GERMANY E-Mail: [email protected]
Phone +49 345 55124-56 Phone +49 9875 9783-170 Hamburg
Fax +49 345 55124-57 Fax +49 9875 9783-171 Breuell + Hilgenfeldt GmbH
[email protected] [email protected] Oststraße 96
Hamburg Offenburg 22844 Norderstedt
Ingenieurbüro Breuell GmbH Dipl.-Ing. (FH) Ralf Braun GERMANY
Ing. Dirk Kahl Hubeneck 21 Phone +49 40 538092-20
Elektroingenieur 77704 Oberkirch Fax +49 40 538092-84
Oststraße 96 GERMANY [email protected]
22844 Norderstedt Phone +49 7802 9822-52 Walter Kluxen GmbH
Accessories

GERMANY Fax +49 7802 9822-53 Neuer Höltigbaum 6


Phone +49 40 538092-19 [email protected] 20097 Hamburg
Fax +49 40 538092-84 GERMANY
Stuttgart
[email protected] Phone +49 40 237010
Dipl.-Ing. (FH) Rudi Weinmann
Hindenburgstraße 100/1 Fax +49 40 23701309
73207 Plochingen
GERMANY
Phone +49 7153 9289-80
Fax +49 7153 9289-81
[email protected]
Representatives
2016-01

Fan agent Compact fan agent Motor specialist Motor agent 265
ebm-papst in Europe

Klausdorf Europe Bulgaria


ETB Electronic Team ebm-papst Romania S.R.L.
Austria
Beratungs- u. Vertriebs GmbH Str. Tarnavei No. 20
ebm-papst Motoren & Ventilatoren GmbH
Zossener Straße 27 500327 Brasov
Straubingstraße 17
15838 Klausdorf ROMANIA
4030 Linz
GERMANY Phone +40 268 331859
AUSTRIA
Phone +49 33703 69-0 Fax +40 268 312805
Phone +43 732 321150-0
Fax +49 33703 69-149 [email protected]
Fax +43 732 321150-20
[email protected]
[email protected] Compex Ges.m.b.H
www.etb-electronic.de
www.ebmpapst.at Wurlitzergasse 10/3
Munich 1160 Wien
Avnet Abacus Vienna
A. Schweiger GmbH AUSTRIA
Schönbrunner Str. 297-307
Ohmstraße 1 Phone +43 1 4804223
1120 Wien
82054 Sauerlach Fax +43 1 4864230
AUSTRIA
GERMANY [email protected]
Phone +43 1 86642-0
Phone +49 8104 897-0
Fax +43 1 86642-250 Croatia
Fax +49 8104 897-90
[email protected] ebm-papst Industries Kft.
[email protected]
www.avnet-abacus.eu Ezred u. 2.
www.schweiger-gmbh.com
1044 Budapest
Compex Ges.m.b.H
Multi-Bauelemente-Service HUNGARY
Wurlitzergasse 10/3
Vertrieb von elektr. Bauelementen GmbH Phone +36 1 8722-190
1160 Wien
Römerstraße 8 Fax +36 1 8722-194
AUSTRIA
85661 Forstinning [email protected]
Phone +43 1 4804223
GERMANY
Fax +43 1 4864230 Compex Ges.m.b.H
Phone +49 8121 2506-0
[email protected] Wurlitzergasse 10/3
Fax +49 8121 2506-200
1160 Wien
[email protected] Belarus
AUSTRIA
ebm-papst Bel AgmbH
Phone +43 1 4804223
(1 to 5 pieces) Lipkovskaya Gasse 34
Fax +43 1 4864230
Office No. 6, Room 106, 107
North [email protected]
223010 Minsk
Breuell + Hilgenfeldt GmbH BELARUS Czech Republic / Slovakia
Oststraße 96 Phone +375 17 3851556 ebm-papst CZ s.r.o.
22844 Norderstedt Fax +375 17 3851556 Kaštanová 34a
GERMANY [email protected] 620 00 Brno
Phone +49 40 538092-20 www.ebmpapst.by CZECH REPUBLIC
Fax +49 40 538092-84 Phone +420 544 502-411
[email protected] Belgium
Fax +420 547 232-622
ebm-papst Benelux B.V.
South [email protected]
Sales office Belgium-Luxemburg
HDS Ventilatoren Vertriebs GmbH www.ebmpapst.cz
Romeinsestraat 6/0101
Glaswiesenstraße 1 Research Park Haasrode Denmark
74677 Dörzbach 3001 Heverlee-Leuven ebm-papst Denmark ApS
GERMANY BELGIUM Vallensbækvej 21
Phone +49 7937 80355-0 Phone +32 16 396-200 2605 Brøndby
Fax +49 7937 80355-25 Fax +32 16 396-220 DENMARK
[email protected] [email protected] Phone +45 43 631111
www.hds-gmbh.net www.ebmpapst.be Fax +45 43 630505
[email protected]
Avnet Abacus Diegem
www.ebmpapst.dk
Eagle Building
Kouterveldstraat 20 Estonia
1831 Diegem ebm-papst Oy, Eesti Filiaal
BELGIUM Kesk tee 13
Phone +32 2 7099 167 Aaviku küla, Jüri Tehnopark
Fax +32 2 7099 801 75301 Rae Vald, Harjumaa
[email protected] ESTONIA
www.avnet-abacus.eu Phone +372 65569-78
Fax +372 65569-79
www.ebmpapst.ee
2016-01

266 Fan agent Compact fan agent Motor specialist Motor agent
Information
ebm-papst in Europe

DC axial fans
DC centrifugal fans
Finland Ireland Poland
ebm-papst Oy ebm-papst UK Ltd. ebm-papst Polska Sp. z o.o.
Puistotie 1 Chelmsford Business Park ul. Annopol 4A
02760 Espoo Chelmsford Essex CM2 5EZ 03236 Warszawa
FINLAND UNITED KINGDOM POLAND
Phone +358 9 887022-0 Phone +44 1245 468555 Phone +48 22 6757819

DC fans - specials
Fax +358 9 887022-13 Fax +44 1245 466336 Fax +48 22 6769587
[email protected] [email protected] [email protected]
www.ebmpapst.fi www.ebmpapst.co.uk www.ebmpapst.pl
France Italy Compex Ges.m.b.H
ebm-papst sarl ebm-papst Srl Wurlitzergasse 10/3
ZI Nord - rue A. Mohler Via Cornaggia 108 1160 Wien
BP 62 22076 Mozzate (Co) AUSTRIA
67212 Obernai Cedex ITALY Phone +43 1 4804223
FRANCE Phone +39 0331 836201 Fax +43 1 4864230
Phone +33 820 326266 Fax +39 0331 821510 [email protected]

ACmaxx / EC fans
Fax +33 3 88673883 [email protected]
Portugal
[email protected] www.ebmpapst.it
ebm-papst (Portugal), Lda.
www.ebmpapst.fr
Macedonia Centro Empresarial de Alverca
Greece ebm-papst Industries Kft. Rua de Adarse, Vale D’Ervas
Helcoma Ezred u. 2. Corpo D / Fracção 3
Th. Rotas & Co OE 1044 Budapest 2615-178 Alverca do Ribatejo
Davaki 65 HUNGARY PORTUGAL
17672 Kallithea-Attiki Phone +36 1 8722-190 Phone +351 218 394 880
GREECE Fax +36 1 8722-194 Fax +351 218 394 759
Phone +30 210 9513-705 [email protected] [email protected]
Fax +30 210 9513-490 www.ebmpapst.pt
Netherlands

AC axial fans
[email protected]
ebm-papst Benelux B.V. Romania
www.helcoma.gr
Polbeemd 7 - 5741 TP Beek en Donk ebm-papst Romania S.R.L.
Assimacopoulos S.A. P. O. Box 140 - 5740 AC Beek en Donk Str. Tarnavei Nr. 20
11, Karitsi Square NETHERLANDS 500327 Brasov
10561 Athen Phone +31 492 502-900 ROMANIA
GREECE Fax +31 492 502-950 Phone +40 268 331859
Phone +30 10 322 1737 [email protected] Fax +40 268 312805
Fax +30 10 322 5708 www.ebmpapst.nl [email protected]
[email protected]
www.assimacopoulos.gr
Avnet Abacus Netherlands Compex Ges.m.b.H AC centrifugal fans
Takkebijsters 2 Wurlitzergasse 10/3
Hungary 4817 BL Breda 1160 Wien
ebm-papst Industries Kft. NETHERLANDS AUSTRIA
Ezred u. 2. Phone +31 765 722 300 Phone +43 1 4804223
1044 Budapest Fax +31 765 722 303 Fax +43 1 4864230
HUNGARY [email protected] [email protected]
Phone +36 1 8722-190 www.avnet-abacus.eu
Russia
Fax +36 1 8722-194
Norway ebm-papst Ural GmbH
[email protected]
ebm-papst AS Posadskaja-Strasse, 23(E), 3
Iceland P. B. 173 Holmlia 620102 Ekaterinburg
Accessories

RJ Engineers 1251 Oslo RUSSIA


Stangarhyl 1a NORWAY Phone +7 343 2338000
110 Reykjavik Phone +47 22 763340 Fax +7 343 2337788
ICELAND Fax +47 22 619173 [email protected]
Phone +354 567 8030 [email protected] www.ebmpapst.ur.ru
Fax +354 567 8015 www.ebmpapst.no
ebm-papst Rus GmbH
[email protected]
proezd 4529, vladenie 5, stroenie 1
www.rj.is
141000 Mytistschi, Oblast Moskau
RUSSIA
Phone +7 495 9807524
Representatives

Fax +7 495 5140924


[email protected]
www.ebmpapst.ru
2016-01

Fan agent Compact fan agent Motor specialist Motor agent 267
ebm-papst in Europe and America

Serbia & Montenegro Ukraine America


ebm-papst Industries Kft. ebm-papst Ukraine LLC
Argentina
Ezred u. 2. Lepse Boulevard, 4, Building 21
ebm-papst de Argentina S.A.
1044 Budapest 03067 Kiev
Hernandarias 148 Lomas del Mirador
HUNGARY UKRAINE
Pcia. de Buenos Aires (1752)
Phone +36 1 8722-190 Phone +38 044 2063091
ARGENTINA
Fax +36 1 8722-194 Fax +38 044 2063091
Phone +54 11 46576135
[email protected] [email protected]
Fax +54 11 46572092
www.ebmpapst.ua
Spain [email protected]
ebm-papst Ibérica S.L. United Kingdom www.ebmpapst.com.ar
Avda. del Sistema Solar, 29 ebm-papst UK Ltd.
Brasil
28830 San Fernando de Henares (Madrid) Chelmsford Business Park
ebm-papst Motores Ventiladores Ltda.
SPAIN Chelmsford Essex CM2 5EZ
Av. José Giorgi, 301 Galpões B6+B7
Phone +34 91 6780894 UNITED KINGDOM
Condominio Logical Center
Fax +34 91 6781530 Phone +44 1245 468555
06707-100 Cotia - São Paulo
[email protected] Fax +44 1245 466336
BRAZIL
www.ebmpapst.es [email protected]
Phone +55 11 4613-8700
www.ebmpapst.co.uk
Sweden Fax +55 11 4777-1456
ebm-papst AB ebm-papst Automotive & Drives (UK) Ltd. [email protected]
Äggelundavägen 2 The Smithy www.ebmpapst.com.br
17562 Järfälla Fidlers Lane
Canada
SWEDEN East Ilsley, Berkshire RG20 7LG
ebm-papst Canada Inc.
Phone +46 10 4544400 UNITED KINGDOM
1800 Ironstone Manor, Unit 2
Fax +46 8 362306 Phone +44 1635 2811-11
Pickering, Ontario, L1W3J9
[email protected] Fax +44 1635 2811-61
CANADA
www.ebmpapst.se A&[email protected]
Phone +1 905 420-3533
www.ebmpapst-ad.com
Switzerland Fax +1 905 420-3772
ebm-papst AG [email protected]
Rütisbergstrasse 1 www.ebmpapst.ca
8156 Oberhasli
Mexico
SWITZERLAND
ebm Industrial S. de R.L. de C.V.
Phone +41 44 73220-70
Paseo de Tamarindos 400-A-5to Piso
Fax +41 44 73220-77
Col. Bosques de las Lomas
[email protected]
Mexico 05120, D.F.
www.ebmpapst.ch
MEXICO
Omni Ray AG Phone +52 55 3300-5144
Im Schörli 5 Fax +52 55 3300-5243
8600 Dübendorf [email protected]
SWITZERLAND www.ebmpapst.com.mx
Phone +41 44 802 2880
USA
Fax +41 44 802 2828
ebm-papst Inc.
[email protected]
P.O. Box 4009
www.omniray.ch
100 Hyde Road
Turkey Farmington, CT 06034
Akantel Elektronik San. Tic. LTD. Sti. UNITED STATES
Atatürk Organize Sanayi Phone +1 860 674-1515
Bölgesi 10007 SK. No.:6 Fax +1 860 674-8536
35620 Cigli-Izmir [email protected]
TURKEY www.ebmpapst.us
Phone +90 232 3282090
ebm-papst Automotive & Drives, Inc.
Fax +90 232 3280270
3200 Greenfield, Suite 255
[email protected]
Dearborn, MI 48120
www.ebmpapst.com.tr
UNITED STATES
Phone +1 313 406-8080
Fax +1 313 406-8081
[email protected]
www.ebmpapst-automotive.us
2016-01

268 Fan agent Compact fan agent Motor specialist Motor agent
Information
ebm-papst in Africa, Asia and Australia

DC axial fans
DC centrifugal fans
Africa Israel TAIWAN
Polak Bros. Import Agencies Ltd. Phone +886 7 557-4268
South Africa
9 Hamefalsim Street Fax +886 7 557-2788
ebm-papst South Africa (Pty) Ltd.
Kiryat Arie, Petach-Tikva 49514 [email protected]
P.O. Box 3124
ISRAEL www.ebmpapst.com.tw
1119 Yacht Avenue
Phone +972 3 9100300
2040 Honeydew Thailand

DC fans - specials
Fax +972 3 5796679
SOUTH AFRICA ebm-papst Thailand Co., Ltd.
[email protected]
Phone +27 11 794-3434 99/9 Moo 2, Central Chaengwattana Tower
www.polak.co.il
Fax +27 11 794-5020 14th Floor, Room 1402
[email protected] AVNET Components Israel LTD Chaengwattana Road Bangtarad, Pakkret
www.ebmpapst.co.za P.O.Box 48 Tel-Mond 4065001 11120 Nonthaburi
ISRAEL THAILAND
Asia Phone +972 9 7780280 Phone +66 2 8353785-7
Fax +972 3 760 1115 Fax +66 2 8353788
China [email protected] [email protected]
ebm-papst Ventilator (Shanghai) Co., Ltd.
Japan United Arab Emirates

ACmaxx / EC fans
No. 418, Hua Jing Road
Wai Gao Qiao Free Trade Zone ebm-papst Japan K.K. ebm-papst Middle East FZE
No. 2001, Yang Gao (N) Road Attend on Tower 13F PO Box 17755
200131 Shanghai Shinyokohama 2-8-12, Kohoku-ku Jebel Ali Free Zone / FZS1 / AP05
P.R. of CHINA 222-0033 Yokohama-City, Kanagawa Dubai
Phone +86 21 5046-0183 JAPAN UNITED ARAB EMIRATES
Fax +86 21 5046-1119 Phone +81 45 47057-51 Phone +971 4 88608-26
[email protected] Fax +81 45 47057-52 Fax +971 4 88608-27
www.ebmpapst.com.cn [email protected] [email protected]
www.ebmpapst.jp www.ebmpapst.ae
Hong Kong
ebm-papst Hong Kong Ltd. Korea Vietnam
ebm-papst Korea Co. Ltd. ebm-papst SEA Pte. Ltd.

AC axial fans
Room 17E, MG Tower
133 Hoi Bun Road, Kwun Tong 6F, Trutec Bldg. Representative Office
Hong Kong 12, WorldCupbuk-ro 56-gil Room 402, 4th Floor, Sai Gon 3 Building
P.R. of CHINA Mapo-Gu 140 Nguyen Van Thu, District 1
Phone +852 2145-8678 Seoul 121-835 Ho Chi Minh City
Fax +852 2145-7678 KOREA VIETNAM
[email protected] Phone +82 2 366213-24 Phone +84 8 39104099 / 39103969
Fax +82 2 366213-26 Fax +84 8 39103970
India [email protected]
ebm-papst India Pvt. Ltd. www.ebmpapst.co.kr Oceania
26/3, G.N.T. Road, Erukkencherry AC centrifugal fans
Chennai-600118 Malaysia Australia
INDIA ebm-papst Malaysia ebm-papst A&NZ Pty Ltd.
Phone +91 44 25372556 Representative Office 10 Oxford Road
Fax +91 44 25371149 Unit 12-2, Jalan USJ Sentral 3 Laverton North, Victoria, 3026
[email protected] Persiaran Subang, Selangor Darul Ehsan AUSTRALIA
www.ebmpapst.in 47600 Subang Jaya Phone +61 3 9360-6400
MALAYSIA Fax +61 3 9360-6464
Indonesia Phone +60 3 8024-1680 [email protected]
ebm-papst Indonesia Fax +60 3 8024-8718 www.ebmpapst.com.au
Representative Office [email protected]
German Centre, 4th Floor, Suite 4470 New Zealand
Accessories

Jl. Kapt. Subijono Dj. Bumi Serpong Damai Singapore ebm-papst A&NZ Pty Ltd.
15321 Tangerang ebm-papst SEA Pte. Ltd. 61 Hugo Johnston Drive, Unit H
INDONESIA No. 23 Ubi Road 4 Penrose 1061, Auckland
Phone +62 21 5376250 #06-00 Olympia Industrial Building NEW ZEALAND
Fax +62 21 5388305 Singapore 408620 PO Box 112278,
[email protected] SINGAPORE Penrose 1642, Auckland
Phone +65 65513789 Phone +64 9 525-0245
Fax +65 68428439 Fax +64 9 525-0246
[email protected] [email protected]
Taiwan www.ebmpapst.com.au
Representatives

ETECO Engineering & Trading Corp.


10F-I, No. 92, Teh-Wei Str.
Tsow-Inn District, Kaohsiung
2016-01

Fan agent Compact fan agent Motor specialist Motor agent 269
2016-01

270
Notes

2016-01

271
www.ebmpapst.com 37634-7-8811 · 2016-01
Printed in Germany

ebm-papst ebm-papst ebm-papst


St. Georgen GmbH & Co. KG Mulfingen GmbH & Co. KG Landshut GmbH

Hermann-Papst-Straße 1 Bachmühle 2 Hofmark-Aich-Straße 25


D-78112 St. Georgen D-74673 Mulfingen D-84030 Landshut
Germany Germany Germany
Phone +49 7724 81-0 Phone +49 7938 81-0 Phone +49 871 707-0
Fax +49 7724 81-1309 Fax +49 7938 81-110 Fax +49 871 707-465
[email protected] [email protected] [email protected]
2016-01

You might also like