T7 SWB
T7 SWB
84477609A 27/09/2011
A.50.A / 87
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 88
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 89
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 90
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 91
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 92
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 93
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 94
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
2011 Clutch pedal potentiometer – voltage too low
2012 Clutch pedal potentiometer – voltage too high
2021 Transmission harness disconnected
2024 All clutches not calibrated
2025 Synchronisers not calibrated
2026 Engine speed – too high
2027 Engine speed – no signal
2035 Dump solenoid – short to 12V
2036 Dump solenoid – short to ground or open circuit
2037 Clutch pedal disconnect switch – open circuit
2047 Clutch pedal disconnect switch set too high
2048 Clutch pedal disconnect switch set too low
2049 Wheel speed (transmission output speed) sensor – short to ground or open circuit
2050 Wheel speed (transmission output speed) sensor – short to 12V
2051 Oil temperature sensor – open circuit
2052 Oil temperature sensor – short circuit
2055 Wheel speed (transmission output speed) sensor – no signal
2059 Shuttle lever switch disagreement ("N" displayed)
2070 Shuttle lever forward switch – voltage too high
2071 Shuttle lever forward switch – voltage too low
2072 Shuttle lever reverse switch – voltage too high
2073 Shuttle lever reverse switch – voltage too low
2075 Flywheel speed sensor signal error
2076 Flywheel speed sensor – open circuit
2077 Flywheel speed sensor – short circuit
2079 Flywheel speed sensor – no signal
2110 Shuttle lever neutral switch - voltage too low
2111 Shuttle lever neutral switch - voltage too high
2124 Flywheel speed sensor not calibrated
2303 Damper calibration – low error
2304 Damper calibration – high error
2331 Clutch slipping fault (CP displayed)
2342 Clutch A solenoid – open circuit or short circuit to ground
2343 Clutch B solenoid – open circuit or short circuit to ground
2352 Clutch A solenoid – voltage too high
2353 Clutch B solenoid – voltage too high
2362 Clutch A not calibrated
2363 Clutch B not calibrated
2380 Parklock – unable to reach desired position
2381 Parklock – bus off
2382 Parklock – bus integrity error
2500 Input over speed error
2501 Oil pressure sensor – open circuit or short circuit to ground
2502 Oil pressure sensor – short circuit to +5V
2503 Clutch A solenoid – in use, an open circuit or short circuit to ground
2504 Clutch B solenoid – in use, an open circuit or short circuit to ground
2505 Clutch A pressure not plausible (mismatch between clutch A pressure and solenoid current)
2506 Clutch B pressure not plausible (mismatch between clutch B pressure and solenoid current)
2517 F2/R1 synchro potentiometer – signal too high
2518 F2/R1 synchro potentiometer – signal too low
2519 Synchro not moving towards F2
2520 Synchro not moving towards R1
2521 F2 solenoid - open circuit or short circuit to ground
2522 R1 solenoid - open circuit or short circuit to ground
2523 F2 solenoid - circuit fault
84477609A 27/09/2011
A.50.A / 95
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
2524 R1 solenoid - circuit fault
2525 F2/R1 synchroniser – neutral did not engage
2538 Ring speed sensor – open circuit or short circuit to ground
2539 Ring speed sensor – short to 12V
2540 A clutch pressure transducer – open circuit or short circuit to ground
2541 B clutch pressure transducer – open circuit or short circuit to ground
2542 A clutch pressure transducer – short circuit to 5V
2543 B clutch pressure transducer – short circuit to 5V
2544 Ring speed sensor critical air gap
2545 Wheel speed (transmission output speed) sensor - critical air gap
2547 Ring speed sensor – no signal
2548 Brake pressure transducer – open circuit or short circuit to ground
2549 Brake pressure transducer – short to 12V
2550 Stuck dump solenoid or clutch A solenoid (mismatch between clutch A pressure command and
pressure sensor reading when clutch A is commanded)
2551 Stuck dump solenoid or clutch B solenoid (mismatch between clutch B pressure command and
pressure sensor reading when clutch B is commanded)
2552 Transmission oil pressure too high
2553 Transmission oil pressure too low
2554 Transmission oil pressure above maximum boost pressure
2555 Transmission oil pressure below warning pressure
2557 Hydro 1 solenoid – open circuit or short circuit to ground
2558 Hydro 1 solenoid – short circuit to 12V
2559 ORPM and Ring sensor fault
2561 Uncommanded movement of synchroniser F2/R1 to neutral
2563 HST inlet (hydro Gport) - pressure too low
2564 HST inlet (hydro Gport) - low pressure warning
2565 HST inlet (hydro Gport) - high pressure warning
2566 HST inlet (hydro Gport) - pressure too high
2567 Gear pump (hydro filter) - pressure too low
2568 Gear pump (hydro filter) - low pressure warning
2569 Gear pump (hydro filter) - high pressure warning
2570 Gear pump (hydro filter) - pressure on filter too high
2571 Hydro Gport pressure sensor - open circuit or short to ground
2572 Hydro Gport pressure sensor - short to 5V
2573 Hydro filter pressure sensor - open circuit or short to ground
2574 Hydro filter pressure sensor - short to 5V
2575 F2/R1 synchroniser transducer - transducer failure
2576 Wheel speed (transmission output speed) sensor #2 - short to ground or open circuit
2577 Wheel speed (transmission output speed) sensor #2 - short to 12V
2578 Wheel speed (transmission output speed) sensor #2 - no signal
2579 Wheel speed (transmission output speed) sensor #2 - critical air gap
84477609A 27/09/2011
A.50.A / 96
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
2027 Engine speed – no signal
2037 Clutch pedal disconnect switch – open circuit
2047 Clutch pedal disconnect switch set too high
2048 Clutch pedal disconnect switch set too low
2049 Wheel speed (transmission output speed) sensor – short to ground or open circuit
2050 Wheel speed (transmission output speed) sensor – short to 12V
2051 Oil temperature sensor – open circuit
2052 Oil temperature sensor – short circuit
2053 5V references – voltage too high
2054 5V references – voltage too low
2055 Wheel speed (transmission output speed) sensor – no signal
2058 Seat switch closed
2059 Shuttle lever switch disagreement ("N" displayed)
2070 Shuttle lever forward switch – voltage too high
2071 Shuttle lever forward switch – voltage too low
2072 Shuttle lever reverse switch – voltage too high
2073 Shuttle lever reverse switch – voltage too low
2075 Flywheel speed sensor signal error
2076 Flywheel speed sensor – open circuit
2077 Flywheel speed sensor – short circuit
2079 Flywheel speed sensor – no signal
2110 Shuttle lever neutral switch - voltage too low
2111 Shuttle lever neutral switch - voltage too high
2124 Flywheel speed sensor not calibrated
2300 19th gear solenoid open circuit or short to ground
2302 19th gear clutch dump solenoid open circuit or short to ground
2303 Damper calibration – low error
2304 Damper calibration – high error
2305 19th gear clutch solenoid over voltage
2306 19th gear clutch dump solenoid over voltage
2308 Reverse not allowed
2314 Forward pressure switch - open circuit or short to ground
2315 Reverse pressure switch - open circuit or short to ground
2316 Transmission oil pressure sensor - not configured
2317 Transmission oil pressure sensor - configuration error
2323 Transmission mid speed sensor - open circuit
2324 Transmission mid speed sensor - short to groundt
2325 Mid speed sensor and output speed sensor swapped
2326 Engine torque/RPM sensor swapped with either mid or output speed sensors
2328 Transmission mid speed sensor - no signal
2330 Transmission output RPM too high for the selected gear
2334 Pressure indicated on the forward clutch pressure switches when the clutch solenoids are off
2335 Pressure indicated on the reverse clutch pressure switches when the clutch solenoids are off
2336 Creeper fails to engage
2337 Creeper fails to disengage
2338 Creeper potentiometer - short circuit to 8V or 12V
2339 Creeper potentiometer - open circuit or short to ground
2342 Clutch A solenoid – open circuit or short circuit to ground
2343 Clutch B solenoid – open circuit or short circuit to ground
2344 Clutch C solenoid – open circuit or short circuit to ground
2345 Clutch D solenoid – open circuit or short circuit to ground
2346 Clutch E solenoid – open circuit or short circuit to ground
2347 Low range clutch solenoid - open circuit or short to ground
2348 Medium range clutch solenoid - open circuit or short to ground
2349 High range clutch solenoid - open circuit or short to ground
84477609A 27/09/2011
A.50.A / 97
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
2350 Reverse clutch solenoid - open circuit or short to ground
2351 Creeper solenoid - open circuit or short to ground
2352 Clutch A solenoid – voltage too high
2353 Clutch B solenoid – voltage too high
2354 Clutch C solenoid – voltage too high
2355 Clutch D solenoid – voltage too high
2356 Clutch E solenoid – voltage too high
2357 Low range clutch solenoid - over voltage
2358 Medium range clutch solenoid - over voltage
2359 High range clutch solenoid - over voltage
2360 Reverse clutch solenoid - over voltage
2361 Creeper solenoid - over voltage
2362 Clutch A not calibrated
2363 Clutch B not calibrated
2364 Clutch C not calibrated
2365 Clutch D not calibrated
2366 Clutch E not calibrated
2367 Low range clutch not calibrated
2368 Medium range clutch not calibrated
2369 High range clutch not calibrated
2370 Reverse clutch not calibrated
2371 Creeper position out of range
2372 Creeper not calibrated
2373 Clutch 19 not calibrated
2374 Creeper calibration error
2375 Creeper - cold oil
2376 Fault on 19th gear
2377 Fault on dump
2380 Parklock – unable to reach desired position
2381 Parklock – bus off
2382 Parklock – bus integrity error
2385 Inconsistent ratio of transmission output speed and engine speed
2501 Oil pressure sensor – open circuit or short circuit to ground
2502 Oil pressure sensor – short circuit to +5V
2601 Pressure mower blower fault
84477609A 27/09/2011
A.50.A / 98
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
2052 Oil temperature sensor – short circuit
2053 5V references – voltage too high
2054 5V references – voltage too low
2055 Wheel speed (transmission output speed) sensor – no signal
2058 Seat switch closed
2059 Shuttle lever switch disagreement ("N" displayed)
2070 Shuttle lever forward switch – voltage too high
2071 Shuttle lever forward switch – voltage too low
2072 Shuttle lever reverse switch – voltage too high
2073 Shuttle lever reverse switch – voltage too low
2075 Flywheel speed sensor signal error
2076 Flywheel speed sensor – open circuit
2077 Flywheel speed sensor – short circuit
2079 Flywheel speed sensor – no signal
2110 Shuttle lever neutral switch - voltage too low
2111 Shuttle lever neutral switch - voltage too high
2124 Flywheel speed sensor not calibrated
2300 19th gear solenoid open circuit or short to ground
2302 19th gear clutch dump solenoid open circuit or short to ground
2303 Damper calibration – low error
2304 Damper calibration – high error
2305 19th gear clutch solenoid over voltage
2306 19th gear clutch dump solenoid over voltage
2308 Reverse not allowed
2316 Transmission oil pressure sensor - not configured
2317 Transmission oil pressure sensor - configuration error
2323 Transmission mid speed sensor - open circuit
2324 Transmission mid speed sensor - short to groundt
2326 Engine torque/RPM sensor swapped with either mid or output speed sensors
2328 Transmission mid speed sensor - no signal
2330 Transmission output RPM too high for the selected gear
2336 Creeper fails to engage
2337 Creeper fails to disengage
2338 Creeper potentiometer - short circuit to 8V or 12V
2339 Creeper potentiometer - open circuit or short to ground
2342 Clutch A solenoid – open circuit or short circuit to ground
2343 Clutch B solenoid – open circuit or short circuit to ground
2344 Clutch C solenoid – open circuit or short circuit to ground
2345 Clutch D solenoid – open circuit or short circuit to ground
2346 Clutch E solenoid – open circuit or short circuit to ground
2347 Low range clutch solenoid - open circuit or short to ground
2348 Medium range clutch solenoid - open circuit or short to ground
2349 High range clutch solenoid - open circuit or short to ground
2350 Reverse clutch solenoid - open circuit or short to ground
2351 Creeper solenoid - open circuit or short to ground
2352 Clutch A solenoid – voltage too high
2353 Clutch B solenoid – voltage too high
2354 Clutch C solenoid – voltage too high
2355 Clutch D solenoid – voltage too high
2356 Clutch E solenoid – voltage too high
2361 Creeper solenoid - over voltage
2362 Clutch A not calibrated
2363 Clutch B not calibrated
2364 Clutch C not calibrated
2365 Clutch D not calibrated
84477609A 27/09/2011
A.50.A / 99
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
2366 Clutch E not calibrated
2371 Creeper position out of range
2372 Creeper not calibrated
2373 Clutch 19 not calibrated
2374 Creeper calibration error
2375 Creeper - cold oil
2380 Parklock – unable to reach desired position
2381 Parklock – bus off
2382 Parklock – bus integrity error
2385 Inconsistent ratio of transmission output speed and engine speed
2400 Low / high range synchroniser not calibrated or bad calibration
2401 Mid / reverse range synchroniser not calibrated or bad calibration
2403 Range shift synchroniser did not engage
2405 Range shift synchroniser did not disengage
2407 Range shift synchroniser did not engage during a shuttle shift
2410 Synchroniser did not disengage during a shuttle shift
2412 Synchroniser did not engage previous range after error code 2403 or 2405
2413 Synchroniser disengaged without operator initiation
2414 Disable range selected by operator
2415 Medium / reverse range synchroniser potentiometer - voltage is too high
2416 Medium / reverse range synchroniser potentiometer - voltage is too low
2417 Low / high range synchroniser potentiometer - voltage is too high
2418 Low / high range synchroniser potentiometer - voltage is too low
2419 Medium / reverse range synchroniser potentiometer - voltage is out of calibrated range
2420 Low / high range synchroniser potentiometer - voltage is out of calibrated range
2425 Attempted to select a disabled range
84477609A 27/09/2011
A.50.A / 100
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
3048 Main relay 2 failure – short circuit to ground
3051 Battery voltage to ECM – voltage too high
3052 Battery voltage to ECM – voltage too low
3059 ECM afterrun was interrupted
3060 Cylinder 1 – unclassifiable error in injector
3061 Cylinder 1 – injector cable short circuit (low side to battery)
3063 Cylinder 1 – injector cable short circuit (high side to battery)
3064 Cylinder 5 – unclassifiable error in injector
3065 Cylinder 5 – injector cable short circuit (low side to battery)
3067 Cylinder 5 – injector cable short circuit (high side to battery)
3068 Cylinder 3 – unclassifiable error in injector
3069 Cylinder 3 – injector cable short circuit (low side to battery)
3071 Cylinder 3 – injector cable short circuit (high side to battery)
3072 Cylinder 6 – unclassifiable error in injector
3073 Cylinder 6 – injector cable short circuit (low side to battery)
3075 Cylinder 6 – injector cable short circuit (high side to battery)
3076 Cylinder 2 – unclassifiable error in injector
3077 Cylinder 2 – injector cable short circuit (low side to battery)
3079 Cylinder 2 – injector cable short circuit (high side to battery)
3080 Cylinder 4 – unclassifiable error in injector
3081 Cylinder 4 – injector cable short circuit (low side to battery)
3083 Cylinder 4 – injector cable short circuit (high side to battery)
3088 Crankshaft sensor – no signal
3089 Crankshaft sensor – invalid signal
3090 Camshaft sensor – no signal
3091 Camshaft sensor – invalid signal
3093 Offset between camshaft and crankshaft – outside boundaries
3095 Operating with camshaft sensor only – backup mode
3096 ECM busoff on vehicle CAN bus
3097 ECM busoff on engine private CAN bus
3102 Rail pressure sensor CP3 – signal below range minimum
3104 Rail pressure relief valve – open
3105 Rail pressure relief valve – pressure shock requested
3106 Rail pressure relief valve – did not open after pressure shock
3107 Metering unit – short circuit to battery
3108 Metering unit – short circuit to ground
3110 Rail pressure sensor offset monitoring – value above limit
3111 Rail pressure sensor offset monitoring – value below limit
3112 Rail pressure sensor CP3 – signal above maximum range
3113 Main relay 1 (High pressure pump - power supply to the fuel metering unit) - short to battery
3114 Main relay 1 (High pressure pump - power supply to the fuel metering unit) - short to ground
3118 ECM 12V sensor - supply voltage high
3119 ECM 12V sensor - supply voltage low
3120 PTO twist sensor – not plausible
3121 PTO twist sensor – open circuit
3122 PTO twist sensor – short circuit to ground
3123 PTO twist sensor – not calibrated
3131 Grid heater always switched on
3137 Metering unit – open load
3138 Metering unit – temperature too high
3141 Fuel flow setpoint too low
3142 High pressure test – test active
3145 Terminal 15 – no signal
3146 Water detected in fuel
84477609A 27/09/2011
A.50.A / 101
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
3147 Oil temperature too high
3148 Coolant temperature sensor dynamic test – failure (minimum temperature raise not reached)
3154 Grid heater relay – short circuit to battery
3155 Grid heater relay – short circuit to ground
3156 Grid heater relay – no load
3157 ECM not detected on CAN bus or anti-tamper security check timeout
3158 Engine anti-tamper - security check failed
3159 Invalid engine reference torque
3160 Fan actuator – short circuit to battery
3161 Fan actuator – short circuit to ground
3162 Fan actuator – no load
3163 Fan actuator – temperature too high
3166 Fuel filter heater relay - short circuit to battery
3167 Fuel filter heater relay - short circuit to ground
3168 Fuel filter heater relay - open load
3169 Fuel filter heater relay - signal not plausible
3176 Setpoint of metering unit not plausible in overrun
3177 Engine overspeed detected
3179 Timeout of CAN message BC2EDC2
3180 Timeout of CAN message VM2EDC
3182 Timeout of CAN message RxCCVS
3183 Timeout of CAN message TSC1-VR (when active)
3184 Timeout of CAN message TSC1-VR (when inactive)
3185 Timeout of CAN message TF
3188 Cylinder 1 warning – open load
3192 Cylinder 2 warning – open load
3196 Cylinder 3 warning – open load
3200 Cylinder 4 warning – open load
3204 Cylinder 5 warning – open load
3208 Cylinder 6 warning – open load
3210 Bank 1 – general short circuit to injection cable
3211 Bank 1 – injection cable short circuit low side to ground
3213 Bank 1 – unclassifiable error
3218 Bank 2 – general short circuit to injection cable
3219 Bank 2 – injection cable short circuit low side to ground
3221 Bank 2 – unclassifiable error
3227 Injection processor (CY33X) error – internal reset / clock loss / voltage too low
3228 Injection processor (CY33X) error – unlocked / initialisation failure
3229 Injection processor (CY33X) error – injections limited by software
3230 Injection processor (CY33X) error – SPI communication failure
3231 Injection processor error – internal reset / clock loss / voltage too low
3232 Injection processor error – unlocked / initialisation failure
3233 Injection processor error – test mode
3234 Injection processor error – SPI communication failure
3238 ECM internal SPI communications error – CJ940
3239 ECM EEPROM – read operation failure
3240 ECM EEPROM – write operation failure
3241 ECM EEPROM – default value used
3242 ECM (locked) recovery occurred
3243 ECM recovery (suppressed) – recovery occurred
3244 ECM recovery (visible) – recovery occurred
3245 ECM processor – watchdog not plausible
3246 Shutoff paths during initialisation – watchdog
3247 Shutoff paths during initialisation – supply voltage too high
3248 Shutoff paths during initialisation – supply voltage too low
84477609A 27/09/2011
A.50.A / 102
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
3249 TPU monitoring – time deviation between TPU and system not plausible
3250 Dataset – variant defect
3251 Dataset – requested variant could not be set
3252 Controller watchdog – SPI communication failure
3253 ADC monitoring – reference voltage too low
3254 ADC monitoring – reference voltage too high
3255 ADC monitoring – test impulse error
3256 ADC monitoring – queue error
3258 High side power - short circuit to battery
3259 High side power - short circuit to ground
3261 Low side power - short circuit to battery of excess temperature
3262 Low side power - short circuit to ground
3265 Overrun monitoring - injection time too long
3266 Redundant engine speed in overrun monitoring - speed signal not plausible
3267 Main relay 3 - short circuit to battery
3268 Main relay 3 - short circuit to ground
3278 ECM internal supply voltage too high - CJ940 above limit
3279 ECM internal supply voltage too low - CJ940 below limit
3280 Sensor supply voltage 1 high
3281 Sensor supply voltage 1 low
3283 Sensor supply voltage 2 high
3284 Sensor supply voltage 2 low
3285 Sensor supply voltage 3 high
3286 Sensor supply voltage 3 low
3297 Rail pressure positive deviation high and high fuel flow setpoint value
3301 Rail pressure negative deviation too high on minimum metering
3305 Rail pressure below minimum limit in controller mode
3309 Rail pressure above maximum limit in controlled mode
3313 Rail pressure drop rate too high
3316 Minimum number of injections not reached – stop engine
3319 DM1DCU SPN2 message - error in DCU active
3320 DM1DCU SPN3 message - error in DCU active
3321 DM1DCU SPN4 message - error in DCU active
3322 DM1DCU SPN5 message - error in DCU active
3334 Timeout of CAN message TSC1–PE Torque (when active)
3335 Timeout of CAN message TSC1–PE Torque (when inactive)
3338 Timeout of CAN message TSC1–VE Speed (when inactive)
3339 Timeout of CAN message TSC1–VE Speed (when active)
3350 Terminal 50 - always on
3354 Main relay 4 (engine brake exhaust valve) short circuit to ground
3355 Main relay 4 (engine brake exhaust valve) short circuit to battery or open load
3358 CAN transmit timeout
3367 Coolant temperature test failure
3368 INFO: Torque limitation due to OBD performance limiter by legislation
3369 INFO: Torque reduction due to smoke reduction
3370 INFO: Torque limitation due to Engine Protection (against excessive torque, engine overspeed and
overheat)
3371 INFO: Torque limitation due to Fuel Quantity Limitation because of injector system errors
3512 DCU state monitoring - DCU not ready in time
3513 SCR catalyst not present - relation of temperature behaviour between both catalyst temperatures
not plausible
3517 Ambient air temperature sensor failure (of humidity sensor) - signal too high
3518 Ambient air temperature sensor failure (of humidity sensor) - signal too low
3521 NOx estimation failure - estimated NOx signal not reliable
3528 NOx sensor plausibility failure - signal not plausible
84477609A 27/09/2011
A.50.A / 103
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
3529 NOx sensor failure - open load
3530 NOx sensor failure - short circuit
3532 NOx sensor failure - sensor not ready in time
3533 CAN message timeout NOx (from NOx sensor) - CAN timeout
3537 CAN message timeout DM1DCU (from DCU) - CAN timeout
3541 CAN message timeout SCR1 (from DCU) - CAN timeout
3545 INFO: SCR dosing valve overheat protection - torque limitation level 2 for SCR protection active
3546 INFO: SCR dosing valve overheat protection - torque limitation level 1 for SCR protection active
3549 Humidity sensor signal ratio failure - signal ratio above limit
3550 Humidity sensor signal ratio failure - signal ratio below limit
3555 CAN message timeout SCR2 (from DCU) - CAN timeout
3557 INFO: Humidity sensor possibly saturated with water droplets - signal ratio above limit
3558 INFO: Humidity sensor possibly saturated with water droplets - signal ratio below limit
3561 NOx value not plausible (aftertreatment plausibility)
3565 Urea quality and urea warning level 1
3569 Urea quality and urea warning level 2
3577 DM1DCU SPN 1 message - error in DCU active
3581 Performance limitation active due to either stage
3585 Engine shut off (after idling phase)
3586 Plausibility check of catalyst system - temperature after catalyst not plausible
3587 Plausibility check of catalyst system - temperature before catalyst not plausible
3588 Plausibility check of catalyst system - ambient temperature of humidity sensor or both catalyst
temperatures not plausible
3589 Plausibility check of catalyst system - temperature deviation between up and downstream catalyst
temperature too high during operation
3591 SCR catalyst thermal ageing limit exceeded - P0422 main catalyst efficiency below threshold
3593 Poor reagent quality
3594 Torque limitation due to SCR
3599 Error path of oxidation catalyst not present - P0421 warm up catalyst efficiency below threshold
3602 Defect ratio between threshold limits - P0425 catalyst temperature sensor circuit
3605 Temperature of Outer control loop - temperature deviation above limit
3606 Temperature of Outer control loop - temperature deviation below limit
3609 Urea quality and urea warning level 4
3611 Catalyst efficiency lower than first Nox prediction threshold level
3612 Catalyst efficiency lower than second Nox prediction threshold level
3613 Too high efficiency of catalyst system
3614 SRA2EDC - high effort fault
3615 SRA2EDC - initialisation fault
3616 Torque limitation due to turbo charger protection
3617 Urea quality and urea warning level 9
3618 Emergency start time expired and shutdown initiated
3619 Urea quality and urea warning level 7
3620 Urea quality and urea warning level 8
3621 Urea quality and urea warning level 5
3623 Lambda signal of NOx sensor deviation (NOx sensor removal is detected)
3999 Unknown ECM SPN Error Code
84477609A 27/09/2011
A.50.A / 104
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
4106 Rear remote no.1 – spool movement too low
4107 Rear remote no.1 – spool movement too high
4108 Rear remote no.1 – float position not reached
4109 Rear remote no.1 – manually operated
4110 Rear remote no.1 – driver faulty
4111 Rear remote no.1 – potentiometer faulty
4112 Rear remote no.1 – unable to reach neutral
4113 Rear remote no.1 – spool not in neutral at key on
4114 Rear remote no.2 – no control message received
4115 Rear remote no.2 – control message not plausible
4116 Rear remote no.2 – EEPROM error
4117 Rear remote no.2 – switched to failsafe
4118 Rear remote no.2 – under voltage
4119 Rear remote no.2 – over voltage
4120 Rear remote no.2 – spool movement too low
4121 Rear remote no.2 – spool movement too high
4122 Rear remote no.2 – float position not reached
4123 Rear remote no.2 – manually operated
4124 Rear remote no.2 – driver faulty
4125 Rear remote no.2 – potentiometer faulty
4126 Rear remote no.2 – unable to reach neutral
4127 Rear remote no.2 – spool not in neutral at key on
4128 Rear remote no.3 – no control message received
4129 Rear remote no.3 – control message not plausible
4130 Rear remote no.3 – EEPROM error
4131 Rear remote no.3 – switched to failsafe
4132 Rear remote no.3 – under voltage
4133 Rear remote no.3 – over voltage
4134 Rear remote no.3 – spool movement too low
4135 Rear remote no.3 – spool movement too high
4136 Rear remote no.3 – float position not reached
4137 Rear remote no.3 – manually operated
4138 Rear remote no.3 – driver faulty
4139 Rear remote no.3 – potentiometer faulty
4140 Rear remote no.3 – unable to reach neutral
4141 Rear remote no.3 – spool not in neutral at key on
4142 Rear remote no.4 – no control message received
4143 Rear remote no.4 – control message not plausible
4144 Rear remote no.4 – EEPROM error
4145 Rear remote no.4 – switched to failsafe
4146 Rear remote no.4 – under voltage
4147 Rear remote no.4 – over voltage
4148 Rear remote no.4 – spool movement too low
4149 Rear remote no.4 – spool movement too high
4150 Rear remote no.4 – float position not reached
4151 Rear remote no.4 – manually operated
4152 Rear remote no.4 – driver faulty
4153 Rear remote no.4 – potentiometer faulty
4154 Rear remote no.4 – unable to reach neutral
4155 Rear remote no.4 – spool not in neutral at key on
4156 Rear remote no.5 – no control message received
4157 Rear remote no.5 – control message not plausible
4158 Rear remote no.5 – EEPROM error
4159 Rear remote no.5 – switched to failsafe
4160 Rear remote no.5 – under voltage
84477609A 27/09/2011
A.50.A / 105
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
4161 Rear remote no.5 – over voltage
4162 Rear remote no.5 – spool movement too low
4163 Rear remote no.5 – spool movement too high
4164 Rear remote no.5 – float position not reached
4165 Rear remote no.5 – manually operated
4166 Rear remote no.5 – driver faulty
4167 Rear remote no.5 – potentiometer faulty
4168 Rear remote no.5 – unable to reach neutral
4169 Rear remote no.5 – spool not in neutral at key on
4170 Rear EHR control No.1 – not calibrated
4173 Rear EHR control No.2 – not calibrated
4177 Rear EHR control no.3 – not calibrated
4180 Rear EHR control no.4 – not calibrated
4190 Rear remote no.1 – no communications
4191 Rear remote no.2 – no communications
4192 Rear remote no.3 – no communications
4193 Rear remote no.4 – no communications
4198 Rear remote no.5 – no communications
4216 Rear remote no.1 – spool not calibrated
4217 Rear remote no.2 – spool not calibrated
4218 Rear remote no.3 – spool not calibrated
4219 Rear remote no.4 – spool not calibrated
4220 Rear remote no.5 – spool not calibrated
84477609A 27/09/2011
A.50.A / 106
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 107
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
4554 Front remote no.4 – unable to reach neutral
4555 Front remote no.4 – spool not in neutral at key on
4560 Front remote no.1 – no communications
4561 Front remote no.2 – no communications
4562 Front remote no.3 – no communications
4563 Front remote no.4 – no communications
4564 EHR joystick – no communications
4565 High flow pump connection error
4566 High flow pump configuration error
84477609A 27/09/2011
A.50.A / 108
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 109
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
12148 CAN – VCU_KEY error / not available
12150 CAN – VCU_HB_SWITCH error / not available
12151 Logic core – second microprocessor not present
12160 Logic core – EEPROM check
12162 ACU temperature – out of range / spike diagnosis
12163 ACU temperature – power stage over temperature
12172 Actuator – cable disconnection
12183 Actuator – actuator moving without command
12184 Actuator – actuator end stop zone reached
12185 Actuator – actuation timeout (energy) expired
12188 Actuator – excess pad wear
12189 Actuator – EPL misuse
12192 Shuttle park – shuttle park invalid status
12202 Handbrake switch – handbrake switch incongruence
12212 Factory – accelerometer not calibrated
12213 Factory – actuator not initialised
12214 Factory – disable actuation
12215 Factory – trailer relay present but not configured
84477609A 27/09/2011
A.50.A / 110
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
14061 Air brake pressure sensor – short circuit to VCC or option set but sensor not connected
14095 Vane pump – short circuit to ground or open circuit
14096 Vane pump – short circuit to VCC
14100 Air brake pressure – not configured
14102 SWCD present - not configured
14106 Steering sensor – present but not configured
14300 Electronic park lock– mismatch between CAN and direct frequency input value
14301 Electronic park lock– direct frequency input shorted to Vcc or open circuit
14304 Electronic park lock– status not validated
14900 Transmission controller missing
14901 Engine controller missing
14904 Armrest controller missing (LC)
14905 Keypad missing (JA)(ADIC only)
14906 Steering controller missing (KA)
14908 TECU missing (OA)
14909 SWCD missing (VA)
14910 Climate controller missing
14911 Enhanced cluster without keypad (New Holland only)
14912 Basic cluster with keypad (New Holland only)
14914 Electronic park lock controller missing (XA)
14920 Configuration error
84477609A 27/09/2011
A.50.A / 111
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
16128 High pressure– low pressure switch (–) input shorted to ground
16129 High pressure cycling error (2 in 1 minute)
16130 Low pressure switch (+) input shorted to power
16131 Low pressure switch (+) input shorted to ground
16132 Low pressure switch (–) input shorted to power
16133 Low pressure switch (–) input shorted to ground
16134 Low pressure switch open for greater than 1 minute
84477609A 27/09/2011
A.50.A / 112
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
18045 EHR 3 lever position – voltage too high
18046 EHR float control switch error
18047 EHR 4 lever position – voltage too low
18048 EHR 4 lever position – voltage too high
18049 Joystick 1 X-axis position – voltage too low
18050 Joystick 1 X-axis position – voltage too high
18051 Joystick 1 Y-axis position – voltage too low
18052 Joystick 1 Y-axis position – voltage too high
18053 Joystick 1 proportional rocker switch – voltage too low
18054 Joystick 1 proportional rocker switch – voltage too high
18055 Joystick 2 X-axis position – voltage too low
18056 Joystick 2 X-axis position – voltage too high
18057 Joystick 2 Y-axis position – voltage too low
18058 Joystick 2 Y-axis position – voltage too high
18059 Joystick 2 proportional rocker switch – voltage too low
18060 Joystick 2 proportional rocker switch – voltage too high
18061 Reference voltage – short circuit to ground
18062 Reference voltage – short circuit to 12V
18063 EEPROM error
18064 MFH communication error
18065 MFH basic assurance test error
18066 EHR 1 lever implausibility error
18067 EHR 2 lever implausibility error
18068 EHR 3 lever implausibility error
18069 EHR 4 lever implausibility error
18070 EHR 5 lever implausibility error
18071 EHR 6 lever implausibility error
18072 EDC mouse raise / work switch fault (NH)
84477609A 27/09/2011
A.50.A / 113
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
19055 UREA Temperature sensor in box (electrical) – signal high – P2045 Reagent - temperature sensor
of pump module - short circuit high
19056 UREA Temperature sensor in box (electrical) – 'signal low – 'P2044 Reagent - temperature sensor
of pump module - short circuit low
19057 UREA Temperature sensor in box (electrical) – signal high – P2043 Reagent - temperature sensor of
pump module - out of range
19058 UREA Temperature sensor in box (electrical) – signal low – P2043 Reagent - temperature sensor of
pump module - out of range
19073 Voltage supply 2 - tube heaters (UB2) electrical – 'Short to bat at UB2 with Key 15 off – 'P20C4
Reagent - suction tube heating - short circuit high
19074 Voltage supply 2 - tube heaters (UB2) electrical – 'Open circuit to UB2 – 'P20C1 Reagent - suction
tube heating - open circuit
19075 Voltage supply 2 - tube heaters (UB2) electrical – 'Short circuit to Ground UB2 – 'P20C3 Reagent -
suction tube heating - short circuit low
19082 Voltage supply 3 - Coolant control valve and reverting valve (UB3) electrical – 'Short to bat at UB3
with Key 15 off – 'P20A3 Vent valve (Reductant Purge Control Valve) - short circuit high
19083 Voltage supply 3 - Coolant control valve and reverting valve (UB3) electrical – 'Open circuit to UB3 –
'P20A0 Vent valve (Reductant Purge Control Valve) - open circuit
19084 Voltage supply 3 - Coolant control valve and reverting valve (UB3) electrical – 'Short circuit to Ground
UB3 – 'P20A2 Vent valve (Reductant Purge Control Valve) - short circuit low
19091 Monitoring VDD11/VDD25 voltage - Dosing valve/pump motor– 'supply voltage VD11 low – 'P0659
12 volt supply for dosing module - below lower limit
19092 Monitoring VDD11/VDD25 voltage - Dosing valve/pump motor– 'supply voltage VD11 high – 'P0658
12 volt supply for dosing module - above upper limit
19093 Monitoring VDD11/VDD25 voltage - Dosing valve/pump motor– 'supply voltage VD25 high – 'P0659
12 volt supply for dosing module - above upper limit
19094 Monitoring VDD11/VDD25 voltage - Dosing valve/pump motor– 'supply voltage VD25 low – 'P0658
12 volt supply for dosing module - below lower limit
19145 Dosing Valve (electrical) – 'short circuit to batt + – 'P2049 Reductant Injector - circuit high
19147 Dosing Valve (electrical) – 'open load – 'P2047 Reductant Injector - circuit open
19149 Dosing Valve (electrical) – short circuit to ground - P0248 Reductant Injector circuit low
19150 Dosing Valve (electrical) – 'Dosing valve permanent "ON" (detection via fast decay) – 'P209B
Reagent - dosing nozzle pressure too high
19154 UREA Pump speed – 'pump motor unplugged – 'P208B Reagent-pump not delivering
19155 UREA Pump speed – pump motor blocked – P208A Reagent-pump
19156 UREA Pump speed – 'pump overspeed – 'P208D Reagent-pump over speed
19157 UREA Pump speed – 'Hall sensors defect – 'P208B Reagent-pump not delivering
19181 Reverting valve (4-2way valve?) electrically – 'Short circuit to battery – 'P20A3 Vent valve (Reductant
Purge Control Valve) - short circuit high
19183 Reverting valve (4-2way valve?) electrically – 'Open load – 'P20A0 Vent valve (Reductant Purge
Control Valve) - open circuit
19184 Reverting valve (4-2way valve?) electrical – short circuit to ground – P20A0 Vent valve (Reductant
Purge Control Valve) - short circuit low
19244 Urea pump heater - short circuit to battery
19247 Urea pump heater - open circuit
19248 Urea pump heater - short circuit to ground
19262 Tank heating Valve – 'Short circuit to battery – 'P20B4 Reagent - tank heating valve - short circuit high
19264 Tank heating Valve – 'Open load – 'P20B1 Reagent - tank heating valve - open circuit
19265 Tank heating Valve – 'Short circuit to ground – 'P20B3 Reagent - tank heating valve - short circuit low
19280 Filterbox heater - short circuit to battery
19283 Filterbox heater - open circuit
19284 Filterbox heater - short circuit to ground
19290 Temperature after catalyst too low – Down stream catalyst temp - physical (Catalyst heating time
failed) – P042B Catalyst Temperature Sensor - Circuit Range/Performance
19298 UREA pressure too low at system start – 'UREA pressure too low at system start – 'P208B Reagent
pump not delivering
84477609A 27/09/2011
A.50.A / 114
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
19307 UREA pressure too high – 'Urea pressure not plausible (urea pressure too high) – 'P204B Reagent
- pressure above threshold
19316 UREA Temperature in Pump Module out of range – 'Urea temperature box - physical (Urea Box Temp
NOT OK: outside range) – 'P2043 Reagent - temperature sensor of pump module out of range
19325 UREA Temperature in Tank out of range – 'Urea temperature tank - physical (Urea Tank Temp NOT
OK: outside range) – 'P205B Reagent - tank temperature sensor (temperature of the Reagent
- solution in the tank) out of range
19334 System frozen and not free in time – Defreezing Mode and Detection Errors (Inlet line defreezing
failed) – P20C2 Reagent - suction tube heating - detection mode of heating
19335 System frozen and not free in time – 'Defreezing Mode and Detection Errors (pressure line defreezing
failed) – 'P20BE Reagent - pressure tube heating - detection mode of heating
19336 System frozen and not free in time – 'Defreezing Mode and Detection Errors (pressure build-up in
detection mode failed) – 'P20C5 Pump module - Internal heating - open circuit
19337 System frozen and not free in time – 'Defreezing Mode and Detection Errors (Back-flow line
defreezing failed) – 'P20B9 Reagent - backflow tube heating - open circuit
19352 Reverting valve (4-2way valve?) mechanically – 'valve does not open – 'P20A0 Vent valve
(Reductant Purge Control Valve) - open circuit
19361 Battery Voltage (actual value) – 'High battery voltage – 'P0562 Battery voltage evaluation - below
lower limit
19362 Battery Voltage (actual value) – Low battery voltage – P0563 Battery voltage evaluation - above
upper limit
19370 UREA pressure too low (in "commissioning" status) – 'Pump motor error during commissioning
(pump not delivering) – 'P208B Reagent-pump not delivering
19379 UREA Temperature too low during commissioning – 'Temperatures not plausible during
commissioning.
19415 Empty UREA Tank – urea tank empty – P203F Reagent - fluid level in tank - too low
19496 Urea pressure sensor plausibility error (checked during system startup)P204B Reagent - pressure -
Above threshold
19505 Urea box temperature sensor plausibility error (dynamic / static) - P2043 Reagent - temperature
sensor of pump module - Out of range
19514 Urea tank temperature sensor plausibility error (dynamic / static) - P205B Reagent - tank temperature
sensor (temperature of the Reagent - solution in the tank) - Out of range
19532 Back flow line clogged – 'P2063 Reagent - dosing valve - short circuit low
19541 Coolant control valve mechanically – 'Blocked closed – 'P20A1 Vent valve test plausibility test
(startup)
19550 Pressure line blocked – 'pressure line blocked – 'P209B Reagent - dosing nozzle - pressure too high
19559 Low UREA level 1 (warning) - UREA level below Limit 1 - P203F Reagent - fluid level in tank - too low
19568 Low UREA level 2 (warning) - UREA level below Limit 2 - P203F Reagent - fluid level in tank - too low
19577 CAN receive frame E2SCR (Dosing, Exh gas flow, Exh gas temp, Error Suppression, Heater, Long
Term failure) – 'SAE J1939 Check for CAN receive signal : (UREA quantity not in range) – 'P0600
Serial Communication Link
19578 CAN receive frame E2SCR (Dosing,Exh gas flow, Exh gas temp, Error Suppression, Heater, Long
Term failure) – 'SAE J1939 Check for CAN receive signal : (Dosing status not in range) – 'P0600
Serial Communication Link
19579 CAN receive frame E2SCR (Dosing, Exh gas flow, Exh gas temp, Error Suppression, Heater, Long
Term failure) – timeout – P0600 Serial Communication Link
19580 CAN receive frame E2SCR (Dosing, Exh gas flow, Exh gas temp, Error Suppression, Heater, Long
Term failure) – 'too many CAN messages – 'P0600 Serial Communication Link
19581 CAN receive frame E2SCR (Dosing,Exh gas flow, Exh gas temp, Error Suppression, Heater, Long
Term failure) – SAE J1939 Check for CAN receive signal – P0600 Serial Communication Link
19595 CAN receive frame EEC1 (Driver demand, eng speed, eng torque) – 'SAE J1939 Check for CAN
receive signal : (Engine torque not in range) – 'P0600 Serial Communication Link
19596 CAN receive frame EEC1 (Driver demand, eng speed, eng torque) – 'SAE J1939 Check for CAN
receive signal : (Engine speed not in range) – 'P0600 Serial Communication Link
19597 CAN receive frame EEC1 (Driver demand, eng speed, eng torque) – timeout – P0600 Serial
Communication Link
19598 CAN receive frame EEC1 (Driver demand, eng speed, eng torque) – 'too many CAN messages –
'P0600 Serial Communication Link
84477609A 27/09/2011
A.50.A / 115
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
19599 CAN receive frame EEC1 (Driver demand, eng speed, eng torque) – 'SAE J1939 Check for CAN
receive signal : (Torque driver demand not in range) – 'P0600 Serial Communication Link
19604 CAN receive frame ET1 (Oil and Water temp engine) – 'SAE J1939 Check for CAN receive signal :
(Oil temperature not in range) – 'P0600 Serial Communication Link
19605 CAN receive frame ET1 (Oil and Water temp engine) – timeout – P0600 Serial Communication Link
19606 CAN receive frame ET1 (Oil and Water temp engine) – 'too many CAN messages – 'P0600 Serial
Communication Link
19607 CAN receive frame ET1 (Oil and Water temp engine) – 'SAE J1939 Check for CAN receive signal :
(Water temperature not in range) – 'P0600 Serial Communication Link
19649 UREA Tank level error (CAN message or electrical with real sensor) – 'Level over CAN: SAE J1939
no Signal available Level sensor connected directly: Sensor Supply error – 'P203A Reagent - tank
level sensor - open circuit
19650 UREA Tank level error (CAN message or electrical with real sensor) – Level over CAN: SAE J1939
Signal Not in Range Level sensor connected directly: SRC high – P203D Reagent - tank level
sensor - short circuit high
19651 UREA Tank level error (CAN message or electrical with real sensor) – 'Level over CAN: SAE J1939
Erroneous Signal Level sensor connected directly: SRC low – 'P203C Reagent - tank level sensor -
short circuit low
19652 UREA Tank level error (CAN message or electrical with real sensor) – (TIMEOUT)
19653 UREA Tank level error (CAN message or electrical with real sensor) – Level over CAN: SAE J1939
Erraneous Signal Level sensor connected directly: SRC low – P203C Reagent - tank level sensor
(too many CAN messages)
19654 UREA Tank level error (CAN message or electrical with real sensor) – Level over CAN: SAE
J1939 Erraneous Signal Level sensor connected directly: SRC low – P203A Reagent - tank level
sensor - Open circuit
19676 Ambient Temperature: SAE J1939 Check for CAN receive signal : (Signal Range Check: Signal not
in range / Erroneous Signal / Signal not available) – 'SAE J1939 Check for CAN receive signal :
(Ambient air temperature not in range) – 'P0600 Serial Communication Link
19677 Ambient Temperature: SAE J1939 Check for CAN receive signal : (Signal Range Check: Signal
not in range / Erroneous Signal / Signal not available) – timeout – P0071 Ambient Air Temperature
Sensor Range/Performance
19678 Ambient Temperature: SAE J1939 Check for CAN receive signal : (Signal Range Check: Signal not
in range / Erroneous Signal / Signal not available) – 'too many CAN messages – 'P0071 Ambient
Air Temperature Sensor Range/Performance
19679 Ambient Temperature: SAE J1939 Check for CAN receive signal : (Signal Range Check: Signal not
in range / Erroneous Signal / Signal not available) – 'SAE J1939 Check for CAN receive signal :
(Barometric pressure not in range) – 'P0071 Ambient Air Temperature Sensor Range/Performance
19721 EEPROM / Checksum failures – 'EEPROM write error – 'P062F Internal Control Module EEPROM
Error
19722 EEPROM / Checksum failures – 'No corresponding variant number error – 'P062F Internal Control
Module EEPROM Error
19723 EEPROM / Checksum failures – 'EEPROM communication error – 'P062F Internal Control Module
EEPROM Error
19724 EEPROM / Checksum failures – EEPROM Detection error OR 'Codierwort error – 'P062F Internal
Control Module EEPROM Error
19725 EEPROM / Checksum failures – 'Wrong EEPROM size – 'P062F Internal Control Module EEPROM
Error
19730 Ignition "on" signal K15 – 'digital input ignition ON not sensed during initialisation – 'P2530 Ignition
switch - plausibility error
19739 Main Relay opens too early / too late – 'main relay shut off too late – 'P0687 ECM/PCM Power
Relay Control Circuit High
19740 Main Relay opens too early / too late – 'main relay short circuit – 'P0685 ECM/PCM Power Relay
Control Circuit /Open
19741 Main Relay opens too early / too late – 'main relay open circuit – 'P0687 ECM/PCM Power Relay
Control Circuit High
19742 Main Relay opens too early / too late – main relay shut off too early (before EEPROM update) –
P0685 ECM/PCM Power Relay Control Circuit /Open
84477609A 27/09/2011
A.50.A / 116
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
19748 Too high UREA Temperature in Pump module or Leakage test failed (Emergency shut off) – over
temperature detection (urea temp. in pump module) – P2043 Reagent - temperature sensor of
pump module - Out of range
19802 UREA Tank Temperature not plausible with pump module temperature - Temp over CAN: SAE J1939
Timeout Temp sensor connected directly SRC high - P0600 Serial Communication Link
19803 UREA Tank Temperature not plausible with pump module temperature - Temp over CAN: SAE J1939
- Too many messages Temp sensor connected directly SRC low - P0600 Serial Communication Link
19804 UREA Tank Temperature not plausible with pump module temperature - Temp over CAN: SAE
J1939 erroneous signal - P205A Reagent - tank temperature sensor (temperature of the Reagent -
solution in tank) - Open circuit
19805 UREA Tank Temperature not plausible with pump module temperature - SRC High - raw value UREA
temperature too high - P205D Reagent - tank temperature sensor (temperature of the Reagent -
solution in the tank) - Short circuit high
19806 UREA Tank Temperature not plausible with pump module temperature - SRC Low - raw value UREA
temperature too low - P205C Reagent - tank temperature sensor (temperature of the Reagent -
solution in the tank) - Short circuit low
19807 UREA Tank Temperature not plausible with pump module temperature - SRC High - diagnostic
value UREA temperature too high - P205B Reagent - tank temperature sensor (temperature of the
Reagent - solution in the tank) - Out of range
19808 UREA Tank Temperature not plausible with pump module temperature - SRC Low - diagnostic
value UREA temperature too low - P205B Reagent - tank temperature sensor (temperature of the
Reagent - solution in the tank) - Out of range
19813 Startup cycle for pressure drop dosing - P208B Reagent pump - Not delivering
19817 Plausibility of UDV stuck - P202F - Reagent dosing valve - Blocked (only stuck closed)
19818 Plausibility of UDV stuck - P202D - Dynamic urea leakage test - Leakage detected
19822 UDV valve stuck position unknown error - P202D Dynamic urea leakage test - Leakage detected
19999 Unknown DeNOX fault code
84477609A 27/09/2011
A.50.A / 117
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 118
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 119
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 120
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 121
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 122
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
1019 Load sensing pin 8V reference – voltage too low
1020 Load sensing pin 8V reference – voltage too high
1021 Draft sensitivity control potentiometer error
1024 Perform the hydraulic lift calibration
1025 Position control potentiometer error
1027 Lift arm position sensor – voltage too low
1028 Lift arm position sensor – voltage too high
1029 Hydraulic control valve disconnected
1031 Chassis harness disconnected
1033 Draft control potentiometer error
1049 Wheel speed sensor open circuit
1053 5 Volt reference 3– voltage too high
1054 5 Volt reference 3– voltage too low
1063 Hydraulic valve lower solenoid – open circuit
1064 Hydraulic valve raise solenoid – open circuit
1065 Hydraulic valve lower solenoid – short circuit
1066 Hydraulic valve raise solenoid – short circuit
1067 Hydraulic valve supply voltage – voltage too low
1068 Height limit control not set to maximum during calibration
1070 Hydraulic ram configuration not set
84477609A 27/09/2011
A.50.A / 123
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
2111 Shuttle lever neutral switch - voltage too high
2124 Flywheel speed sensor not calibrated
2300 19th gear solenoid open circuit or short to ground
2302 19th gear clutch dump solenoid open circuit or short to ground
2303 Damper calibration – low error
2304 Damper calibration – high error
2305 19th gear clutch solenoid over voltage
2306 19th gear clutch dump solenoid over voltage
2308 Reverse not allowed
2314 Forward pressure switch - open circuit or short to ground
2315 Reverse pressure switch - open circuit or short to ground
2316 Transmission oil pressure sensor - not configured
2317 Transmission oil pressure sensor - configuration error
2323 Transmission mid speed sensor - open circuit
2324 Transmission mid speed sensor - short to ground
2325 Mid speed sensor and output speed sensor swapped
2326 Engine torque/RPM sensor swapped with either mid or output speed sensors
2328 Transmission mid speed sensor - no signal
2330 Transmission output RPM too high for the selected gear
2334 Pressure indicated on the forward clutch pressure switches when the clutch solenoids are off
2335 Pressure indicated on the reverse clutch pressure switches when the clutch solenoids are off
2336 Creeper fails to engage
2337 Creeper fails to disengage
2338 Creeper potentiometer - short circuit to 8V or 12V
2339 Creeper potentiometer - open circuit or short to ground
2342 Clutch A solenoid – open circuit or short circuit to ground
2343 Clutch B solenoid – open circuit or short circuit to ground
2344 Clutch C solenoid – open circuit or short circuit to ground
2345 Clutch D solenoid – open circuit or short circuit to ground
2346 Clutch E solenoid – open circuit or short circuit to ground
2347 Low range clutch solenoid - open circuit or short to ground
2348 Medium range clutch solenoid - open circuit or short to ground
2349 High range clutch solenoid - open circuit or short to ground
2350 Reverse clutch solenoid - open circuit or short to ground
2351 Creeper solenoid - open circuit or short to ground
2352 Clutch A solenoid – voltage too high
2353 Clutch B solenoid – voltage too high
2354 Clutch C solenoid – voltage too high
2355 Clutch D solenoid – voltage too high
2356 Clutch E solenoid – voltage too high
2357 Low range clutch solenoid - over voltage
2358 Medium range clutch solenoid - over voltage
2359 High range clutch solenoid - over voltage
2360 Reverse clutch solenoid - over voltage
2361 Creeper solenoid - over voltage
2362 Clutch A not calibrated
2363 Clutch B not calibrated
2364 Clutch C not calibrated
2365 Clutch D not calibrated
2366 Clutch E not calibrated
2367 Low range clutch not calibrated
2368 Medium range clutch not calibrated
2369 High range clutch not calibrated
2370 Reverse clutch not calibrated
2371 Creeper position out of range
84477609A 27/09/2011
A.50.A / 124
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
2372 Creeper not calibrated
2373 Clutch 19 not calibrated
2374 Creeper calibration error
2375 Creeper - cold oil
2376 Fault on 19th gear
2377 Fault on dump
2380 Parklock – unable to reach desired position
2381 Parklock – bus off
2382 Parklock – bus integrity error
2385 Inconsistent ratio of transmission output speed and engine speed
2501 Oil pressure sensor – open circuit or short circuit to ground
2502 Oil pressure sensor – short circuit to +5V
84477609A 27/09/2011
A.50.A / 125
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
2308 Reverse not allowed
2316 Transmission oil pressure sensor - not configured
2317 Transmission oil pressure sensor - configuration error
2323 Transmission mid speed sensor - open circuit
2324 Transmission mid speed sensor - short to ground
2328 Transmission mid speed sensor - no signal
2330 Transmission output RPM too high for the selected gear
2336 Creeper fails to engage
2337 Creeper fails to disengage
2338 Creeper potentiometer - short circuit to 8V or 12V
2339 Creeper potentiometer - open circuit or short to ground
2342 Clutch A solenoid – open circuit or short circuit to ground
2343 Clutch B solenoid – open circuit or short circuit to ground
2344 Clutch C solenoid – open circuit or short circuit to ground
2345 Clutch D solenoid – open circuit or short circuit to ground
2346 Clutch E solenoid – open circuit or short circuit to ground
2347 Low range clutch solenoid - open circuit or short to ground
2348 Medium range clutch solenoid - open circuit or short to ground
2349 High range clutch solenoid - open circuit or short to ground
2350 Reverse clutch solenoid - open circuit or short to ground
2351 Creeper solenoid - open circuit or short to ground
2352 Clutch A solenoid – voltage too high
2353 Clutch B solenoid – voltage too high
2354 Clutch C solenoid – voltage too high
2355 Clutch D solenoid – voltage too high
2356 Clutch E solenoid – voltage too high
2361 Creeper solenoid - over voltage
2362 Clutch A not calibrated
2363 Clutch B not calibrated
2364 Clutch C not calibrated
2365 Clutch D not calibrated
2366 Clutch E not calibrated
2371 Creeper position out of range
2372 Creeper not calibrated
2373 Clutch 19 not calibrated
2374 Creeper calibration error
2375 Creeper - cold oil
2380 Parklock – unable to reach desired position
2381 Parklock – bus off
2382 Parklock – bus integrity error
2385 Inconsistent ratio of transmission output speed and engine speed
2400 Low / high range synchroniser not calibrated or bad calibration
2401 Mid / reverse range synchroniser not calibrated or bad calibration
2403 Range shift synchroniser did not engage
2405 Range shift synchroniser did not disengage
2407 Range shift synchroniser did not engage during a shuttle shift
2410 Synchroniser did not disengage during a shuttle shift
2412 Synchroniser did not engage previous range after error code 2403 or 2405
2413 Synchroniser disengaged without operator initiation
2414 Disable range selected by operator
2415 Medium / reverse range synchroniser potentiometer - voltage is too high
2416 Medium / reverse range synchroniser potentiometer - voltage is too low
2417 Low / high range synchroniser potentiometer - voltage is too high
2418 Low / high range synchroniser potentiometer - voltage is too low
2419 Medium / reverse range synchroniser potentiometer - voltage is out of calibrated range
84477609A 27/09/2011
A.50.A / 126
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
2420 Low / high range synchroniser potentiometer - voltage is out of calibrated range
2425 Attempted to select a disabled range
84477609A 27/09/2011
A.50.A / 127
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
3090 Camshaft sensor – no signal
3091 Camshaft sensor – invalid signal
3093 Offset between camshaft and crankshaft – outside boundaries
3095 Operating with camshaft sensor only – backup mode
3096 ECM busoff on vehicle CAN bus
3097 ECM busoff on engine private CAN bus
3102 Rail pressure sensor CP3 – signal below range minimum
3104 Rail pressure relief valve – open
3105 Rail pressure relief valve – pressure shock requested
3106 Rail pressure relief valve – did not open after pressure shock
3107 Metering unit – short circuit to battery
3108 Metering unit – short circuit to ground
3110 Rail pressure sensor offset monitoring – value above limit
3111 Rail pressure sensor offset monitoring – value below limit
3112 Rail pressure sensor CP3 – signal above maximum range
3113 Main relay 1 (High pressure pump - power supply to the fuel metering unit) - short to battery
3114 Main relay 1 (High pressure pump - power supply to the fuel metering unit) - short to ground
3118 ECM 12V sensor - supply voltage high
3119 ECM 12V sensor - supply voltage low
3120 PTO twist sensor – not plausible
3121 PTO twist sensor – open circuit
3122 PTO twist sensor – short circuit to ground
3123 PTO twist sensor – not calibrated
3131 Grid heater always switched on
3137 Metering unit – open load
3138 Metering unit – temperature too high
3141 Fuel flow setpoint too low
3142 High pressure test – test active
3145 Terminal 15 – no signal
3146 Water detected in fuel
3147 Oil temperature too high
3148 Coolant temperature sensor dynamic test – failure (minimum temperature raise not reached)
3154 Grid heater relay – short circuit to battery
3155 Grid heater relay – short circuit to ground
3156 Grid heater relay – no load
3157 ECM not detected on CAN bus or anti-tamper security check timeout
3158 Engine anti-tamper - security check failed
3159 Invalid engine reference torque
3160 Fan actuator – short circuit to battery
3161 Fan actuator – short circuit to ground
3162 Fan actuator – no load
3163 Fan actuator – temperature too high
3166 Fuel filter heater relay - short circuit to battery
3167 Fuel filter heater relay - short circuit to ground
3168 Fuel filter heater relay - open load
3169 Fuel filter heater relay - signal not plausible
3176 Setpoint of metering unit not plausible in overrun
3177 Engine overspeed detected
3179 Timeout of CAN message BC2EDC2
3180 Timeout of CAN message VM2EDC
3182 Timeout of CAN message RxCCVS
3183 Timeout of CAN message TSC1-VR (when active)
3184 Timeout of CAN message TSC1-VR (when inactive)
3185 Timeout of CAN message TF
3188 Cylinder 1 warning – open load
84477609A 27/09/2011
A.50.A / 128
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
3192 Cylinder 2 warning – open load
3196 Cylinder 3 warning – open load
3200 Cylinder 4 warning – open load
3204 Cylinder 5 warning – open load
3208 Cylinder 6 warning – open load
3210 Bank 1 – general short circuit to injection cable
3211 Bank 1 – injection cable short circuit low side to ground
3213 Bank 1 – unclassifiable error
3218 Bank 2 – general short circuit to injection cable
3219 Bank 2 – injection cable short circuit low side to ground
3221 Bank 2 – unclassifiable error
3227 Injection processor (CY33X) error – internal reset / clock loss / voltage too low
3228 Injection processor (CY33X) error – unlocked / initialisation failure
3229 Injection processor (CY33X) error – injections limited by software
3230 Injection processor (CY33X) error – SPI communication failure
3231 Injection processor error – internal reset / clock loss / voltage too low
3232 Injection processor error – unlocked / initialisation failure
3233 Injection processor error – test mode
3234 Injection processor error – SPI communication failure
3238 ECM internal SPI communications error – CJ940
3239 ECM EEPROM – read operation failure
3240 ECM EEPROM – write operation failure
3241 ECM EEPROM – default value used
3242 ECM (locked) recovery occurred
3243 ECM recovery (suppressed) – recovery occurred
3244 ECM recovery (visible) – recovery occurred
3245 ECM processor – watchdog not plausible
3246 Shutoff paths during initialisation – watchdog
3247 Shutoff paths during initialisation – supply voltage too high
3248 Shutoff paths during initialisation – supply voltage too low
3249 TPU monitoring – time deviation between TPU and system not plausible
3250 Dataset – variant defect
3251 Dataset – requested variant could not be set
3252 Controller watchdog – SPI communication failure
3253 ADC monitoring – reference voltage too low
3254 ADC monitoring – reference voltage too high
3255 ADC monitoring – test impulse error
3256 ADC monitoring – queue error
3258 High side power - short circuit to battery
3259 High side power - short circuit to ground
3261 Low side power - short circuit to battery of excess temperature
3262 Low side power - short circuit to ground
3265 Overrun monitoring - injection time too long
3266 Redundant engine speed in overrun monitoring - speed signal not plausible
3267 Main relay 3 - short circuit to battery
3268 Main relay 3 - short circuit to ground
3278 ECM internal supply voltage too high - CJ940 above limit
3279 ECM internal supply voltage too low - CJ940 below limit
3280 Sensor supply voltage 1 high
3281 Sensor supply voltage 1 low
3283 Sensor supply voltage 2 high
3284 Sensor supply voltage 2 low
3285 Sensor supply voltage 3 high
3286 Sensor supply voltage 3 low
3297 Rail pressure positive deviation high and high fuel flow setpoint value
84477609A 27/09/2011
A.50.A / 129
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
3301 Rail pressure negative deviation too high on minimum metering
3305 Rail pressure below minimum limit in controller mode
3309 Rail pressure above maximum limit in controlled mode
3313 Rail pressure drop rate too high
3316 Minimum number of injections not reached – stop engine
3319 DM1DCU SPN2 message - error in DCU active
3320 DM1DCU SPN3 message - error in DCU active
3321 DM1DCU SPN4 message - error in DCU active
3322 DM1DCU SPN5 message - error in DCU active
3334 Timeout of CAN message TSC1–PE Torque (when active)
3335 Timeout of CAN message TSC1–PE Torque (when inactive)
3338 Timeout of CAN message TSC1–VE Speed (when inactive)
3339 Timeout of CAN message TSC1–VE Speed (when active)
3350 Terminal 50 - always on
3354 Main relay 4 (engine brake exhaust valve) short circuit to ground
3355 Main relay 4 (engine brake exhaust valve) short circuit to battery or open load
3358 CAN transmit timeout
3367 Coolant temperature test failure
3368 INFO: Torque limitation due to OBD performance limiter by legislation
3369 INFO: Torque reduction due to smoke reduction
3370 INFO: Torque limitation due to Engine Protection (against excessive torque, engine overspeed and
overheat)
3371 INFO: Torque limitation due to Fuel Quantity Limitation because of injector system errors
3512 DCU state monitoring - DCU not ready in time
3513 SCR catalyst not present - relation of temperature behaviour between both catalyst temperatures
not plausible
3517 Ambient air temperature sensor failure (of humidity sensor) - signal too high
3518 Ambient air temperature sensor failure (of humidity sensor) - signal too low
3521 NOx estimation failure - estimated NOx signal not reliable
3528 NOx sensor plausibility failure - signal not plausible
3529 NOx sensor failure - open load
3530 NOx sensor failure - short circuit
3532 NOx sensor failure - sensor not ready in time
3533 CAN message timeout NOx (from NOx sensor) - CAN timeout
3537 CAN message timeout DM1DCU (from DCU) - CAN timeout
3541 CAN message timeout SCR1 (from DCU) - CAN timeout
3545 INFO: SCR dosing valve overheat protection - torque limitation level 2 for SCR protection active
3546 INFO: SCR dosing valve overheat protection - torque limitation level 1 for SCR protection active
3549 Humidity sensor signal ratio failure - signal ratio above limit
3550 Humidity sensor signal ratio failure - signal ratio below limit
3555 CAN message timeout SCR2 (from DCU) - CAN timeout
3557 INFO: Humidity sensor possibly saturated with water droplets - signal ratio above limit
3558 INFO: Humidity sensor possibly saturated with water droplets - signal ratio below limit
3561 NOx value not plausible (aftertreatment plausibility)
3577 DM1DCU SPN 1 message - error in DCU active
3581 Performance limitation active due to either stage
3585 Engine shut off (after idling phase)
3586 Plausibility check of catalyst system - temperature after catalyst not plausible
3587 Plausibility check of catalyst system - temperature before catalyst not plausible
3588 Plausibility check of catalyst system - ambient temperature of humidity sensor or both catalyst
temperatures not plausible
3589 Plausibility check of catalyst system - temperature deviation between up and downstream catalyst
temperature too high during operation
3591 SCR catalyst thermal ageing limit exceeded - P0422 main catalyst efficiency below threshold
3593 Poor reagent quality
84477609A 27/09/2011
A.50.A / 130
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
3594 Torque limitation due to SCR
3599 Error path of oxidation catalyst not present - P0421 warm up catalyst efficiency below threshold
3602 Defect ratio between threshold limits - P0425 catalyst temperature sensor circuit
3605 Temperature of Outer control loop - temperature deviation above limit
3606 Temperature of Outer control loop - temperature deviation below limit
3609 Urea quality and urea warning level 4
3611 Catalyst efficiency lower than first Nox prediction threshold level
3612 Catalyst efficiency lower than second Nox prediction threshold level
3613 Too high efficiency of catalyst system
3614 SRA2EDC - high effort fault
3615 SRA2EDC - initialisation fault
3616 Torque limitation due to turbo charger protection
3617 Urea quality and urea warning level 9
3618 Emergency start time expired and shutdown initiated
3619 Urea quality and urea warning level 7
3620 Urea quality and urea warning level 8
3621 Urea quality and urea warning level 5
3623 Lambda signal of NOx sensor deviation (NOx sensor removal is detected)
3999 Unknown ECM SPN Error Code
84477609A 27/09/2011
A.50.A / 131
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
4133 Rear remote no.3 – over voltage
4134 Rear remote no.3 – spool movement too low
4135 Rear remote no.3 – spool movement too high
4136 Rear remote no.3 – float position not reached
4137 Rear remote no.3 – manually operated
4138 Rear remote no.3 – driver faulty
4139 Rear remote no.3 – potentiometer faulty
4140 Rear remote no.3 – unable to reach neutral
4141 Rear remote no.3 – spool not in neutral at key on
4142 Rear remote no.4 – no control message received
4143 Rear remote no.4 – control message not plausible
4144 Rear remote no.4 – EEPROM error
4145 Rear remote no.4 – switched to failsafe
4146 Rear remote no.4 – under voltage
4147 Rear remote no.4 – over voltage
4148 Rear remote no.4 – spool movement too low
4149 Rear remote no.4 – spool movement too high
4150 Rear remote no.4 – float position not reached
4151 Rear remote no.4 – manually operated
4152 Rear remote no.4 – driver faulty
4153 Rear remote no.4 – potentiometer faulty
4154 Rear remote no.4 – unable to reach neutral
4155 Rear remote no.4 – spool not in neutral at key on
4156 Rear remote no.5 – no control message received
4157 Rear remote no.5 – control message not plausible
4158 Rear remote no.5 – EEPROM error
4159 Rear remote no.5 – switched to failsafe
4160 Rear remote no.5 – under voltage
4161 Rear remote no.5 – over voltage
4162 Rear remote no.5 – spool movement too low
4163 Rear remote no.5 – spool movement too high
4164 Rear remote no.5 – float position not reached
4165 Rear remote no.5 – manually operated
4166 Rear remote no.5 – driver faulty
4167 Rear remote no.5 – potentiometer faulty
4168 Rear remote no.5 – unable to reach neutral
4169 Rear remote no.5 – spool not in neutral at key on
4170 Rear EHR control No.1 – not calibrated
4173 Rear EHR control No.2 – not calibrated
4177 Rear EHR control no.3 – not calibrated
4180 Rear EHR control no.4 – not calibrated
4190 Rear remote no.1 – no communications
4191 Rear remote no.2 – no communications
4192 Rear remote no.3 – no communications
4193 Rear remote no.4 – no communications
4198 Rear remote no.5 – no communications
4216 Rear remote no.1 – spool not calibrated
4217 Rear remote no.2 – spool not calibrated
4218 Rear remote no.3 – spool not calibrated
4219 Rear remote no.4 – spool not calibrated
4220 Rear remote no.5 – spool not calibrated
84477609A 27/09/2011
A.50.A / 132
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 133
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
4554 Front remote no.4 – unable to reach neutral
4555 Front remote no.4 – spool not in neutral at key on
4560 Front remote no.1 – no communications
4561 Front remote no.2 – no communications
4562 Front remote no.3 – no communications
4563 Front remote no.4 – no communications
4564 EHR joystick – no communications
4565 High flow pump connection error
4566 High flow pump configuration error
84477609A 27/09/2011
A.50.A / 134
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
84477609A 27/09/2011
A.50.A / 135
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
12163 ACU temperature – power stage over temperature
12172 Actuator – cable disconnection
12183 Actuator – actuator moving without command
12184 Actuator – actuator end stop zone reached
12185 Actuator – actuation timeout (energy) expired
12188 Actuator – excess pad wear
12189 Actuator – EPL misuse
12192 Shuttle park – shuttle park invalid status
12202 Handbrake switch – handbrake switch incongruence
12212 Factory – accelerometer not calibrated
12213 Factory – actuator not initialised
12214 Factory – disable actuation
12215 Factory – trailer relay present but not configured
84477609A 27/09/2011
A.50.A / 136
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
14914 Electronic park lock controller missing (XA)
14920 Configuration error
84477609A 27/09/2011
A.50.A / 137
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
19020 Temperature sensor before catalyst (electrical) – 'signal low – 'P0427 Catalyst Temperature Sensor
Circuit Low
19021 Temperature sensor before catalyst (electrical) – signal high – signal above high error threshold
19022 Temperature sensor before catalyst (electrical) – signal low – signal below low error threshold
19037 Sensor supply 2 (5V internal; for UREA pressure sensors) – Supply Voltage too high – P204D
Reagent - pressure sensor - short circuit high
19038 Sensor supply 2 (5V internal; for UREA pressure sensors) – 'Supply voltage too low – 'P204C
Reagent - pressure sensor - short circuit low
19046 UREA pressure sensor in box (electrical) – 'supply voltage error – 'P204A Reagent - pressure
sensor - open circuit
19047 UREA pressure sensor in box (electrical) – signal high – P204D Reagent - pressure sensor - short
circuit high
19048 UREA pressure sensor in box (electrical) – 'signal low – 'P204C Reagent - pressure sensor - short
circuit low
19055 UREA Temperature sensor in box (electrical) – signal high – P2045 Reagent - temperature sensor
of pump module - short circuit high
19056 UREA Temperature sensor in box (electrical) – 'signal low – 'P2044 Reagent - temperature sensor
of pump module - short circuit low
19057 UREA Temperature sensor in box (electrical) – signal high – P2043 Reagent - temperature sensor of
pump module - out of range
19058 UREA Temperature sensor in box (electrical) – signal low – P2043 Reagent - temperature sensor of
pump module - out of range
19073 Voltage supply 2 - tube heaters (UB2) electrical – 'Short to bat at UB2 with Key 15 off – 'P20C4
Reagent - suction tube heating - short circuit high
19074 Voltage supply 2 - tube heaters (UB2) electrical – 'Open circuit to UB2 – 'P20C1 Reagent - suction
tube heating - open circuit
19075 Voltage supply 2 - tube heaters (UB2) electrical – 'Short circuit to Ground UB2 – 'P20C3 Reagent -
suction tube heating - short circuit low
19082 Voltage supply 3 - Coolant control valve and reverting valve (UB3) electrical – 'Short to bat at UB3
with Key 15 off – 'P20A3 Vent valve (Reductant Purge Control Valve) - short circuit high
19083 Voltage supply 3 - Coolant control valve and reverting valve (UB3) electrical – 'Open circuit to UB3 –
'P20A0 Vent valve (Reductant Purge Control Valve) - open circuit
19084 Voltage supply 3 - Coolant control valve and reverting valve (UB3) electrical – 'Short circuit to Ground
UB3 – 'P20A2 Vent valve (Reductant Purge Control Valve) - short circuit low
19091 Monitoring VDD11/VDD25 voltage - Dosing valve/pump motor– 'supply voltage VD11 low – 'P0659
12 volt supply for dosing module - below lower limit
19092 Monitoring VDD11/VDD25 voltage - Dosing valve/pump motor– 'supply voltage VD11 high – 'P0658
12 volt supply for dosing module - above upper limit
19093 Monitoring VDD11/VDD25 voltage - Dosing valve/pump motor– 'supply voltage VD25 high – 'P0659
12 volt supply for dosing module - above upper limit
19094 Monitoring VDD11/VDD25 voltage - Dosing valve/pump motor– 'supply voltage VD25 low – 'P0658
12 volt supply for dosing module - below lower limit
19145 Dosing Valve (electrical) – 'short circuit to batt + – 'P2049 Reductant Injector - circuit high
19147 Dosing Valve (electrical) – 'open load – 'P2047 Reductant Injector - circuit open
19149 Dosing Valve (electrical) – short circuit to ground - P0248 Reductant Injector circuit low
19150 Dosing Valve (electrical) – 'Dosing valve permanent "ON" (detection via fast decay) – 'P209B
Reagent - dosing nozzle pressure too high
19154 UREA Pump speed – 'pump motor unplugged – 'P208B Reagent-pump not delivering
19155 UREA Pump speed – pump motor blocked – P208A Reagent-pump
19156 UREA Pump speed – 'pump overspeed – 'P208D Reagent-pump over speed
19157 UREA Pump speed – 'Hall sensors defect – 'P208B Reagent-pump not delivering
19181 Reverting valve (4-2way valve?) electrically – 'Short circuit to battery – 'P20A3 Vent valve (Reductant
Purge Control Valve) - short circuit high
19183 Reverting valve (4-2way valve?) electrically – 'Open load – 'P20A0 Vent valve (Reductant Purge
Control Valve) - open circuit
19262 Tank heating Valve – 'Short circuit to battery – 'P20B4 Reagent - tank heating valve - short circuit high
19264 Tank heating Valve – 'Open load – 'P20B1 Reagent - tank heating valve - open circuit
84477609A 27/09/2011
A.50.A / 138
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
19265 Tank heating Valve – 'Short circuit to ground – 'P20B3 Reagent - tank heating valve - short circuit low
19290 Temperature after catalyst too low – Down stream catalyst temp - physical (Catalyst heating time
failed) – P042B Catalyst Temperature Sensor - Circuit Range/Performance
19298 UREA pressure too low at system start – 'UREA pressure too low at system start – 'P208B Reagent
pump not delivering
19307 UREA pressure too high – 'Urea pressure not plausible (urea pressure too high) – 'P204B Reagent
- pressure above threshold
19316 UREA Temperature in Pump Module out of range – 'Urea temperature box - physical (Urea Box Temp
NOT OK: outside range) – 'P2043 Reagent - temperature sensor of pump module out of range
19325 UREA Temperature in Tank out of range – 'Urea temperature tank - physical (Urea Tank Temp NOT
OK: outside range) – 'P205B Reagent - tank temperature sensor (temperature of the Reagent
- solution in the tank) out of range
19334 System frozen and not free in time – Defreezing Mode and Detection Errors (Inlet line defreezing
failed) – P20C2 Reagent - suction tube heating - detection mode of heating
19335 System frozen and not free in time – 'Defreezing Mode and Detection Errors (pressure line defreezing
failed) – 'P20BE Reagent - pressure tube heating - detection mode of heating
19336 System frozen and not free in time – 'Defreezing Mode and Detection Errors (pressure build-up in
detection mode failed) – 'P20C5 Pump module - Internal heating - open circuit
19337 System frozen and not free in time – 'Defreezing Mode and Detection Errors (Back-flow line
defreezing failed) – 'P20B9 Reagent - backflow tube heating - open circuit
19352 Reverting valve (4-2way valve?) mechanically – 'valve does not open – 'P20A0 Vent valve
(Reductant Purge Control Valve) - open circuit
19361 Battery Voltage (actual value) – 'High battery voltage – 'P0562 Battery voltage evaluation - below
lower limit
19362 Battery Voltage (actual value) – Low battery voltage – P0563 Battery voltage evaluation - above
upper limit
19370 UREA pressure too low (in "commissioning" status) – 'Pump motor error during commissioning
(pump not delivering) – 'P208B Reagent-pump not delivering
19379 UREA Temperature too low during commissioning – 'Temperatures not plausible during
commissioning.
19415 Empty UREA Tank – urea tank empty – P203F Reagent - fluid level in tank - too low
19496 Urea pressure sensor plausibility error (checked during system startup)P204B Reagent - pressure -
Above threshold
19505 Urea box temperature sensor plausibility error (dynamic / static) - P2043 Reagent - temperature
sensor of pump module - Out of range
19514 Urea tank temperature sensor plausibility error (dynamic / static) - P205B Reagent - tank temperature
sensor (temperature of the Reagent - solution in the tank) - Out of range
19532 Back flow line clogged – 'P2063 Reagent - dosing valve - short circuit low
19541 Coolant control valve mechanically – 'Blocked closed – 'P20A1 Vent valve test plausibility test
(startup)
19550 Pressure line blocked – 'pressure line blocked – 'P209B Reagent - dosing nozzle - pressure too high
19559 Low UREA level 1 (warning) - UREA level below Limit 1 - P203F Reagent - fluid level in tank - too low
19568 Low UREA level 2 (warning) - UREA level below Limit 2 - P203F Reagent - fluid level in tank - too low
19577 CAN receive frame E2SCR (Dosing, Exh gas flow, Exh gas temp, Error Suppression, Heater, Long
Term failure) – 'SAE J1939 Check for CAN receive signal : (UREA quantity not in range) – 'P0600
Serial Communication Link
19578 CAN receive frame E2SCR (Dosing,Exh gas flow, Exh gas temp, Error Suppression, Heater, Long
Term failure) – 'SAE J1939 Check for CAN receive signal : (Dosing status not in range) – 'P0600
Serial Communication Link
19579 CAN receive frame E2SCR (Dosing, Exh gas flow, Exh gas temp, Error Suppression, Heater, Long
Term failure) – timeout – P0600 Serial Communication Link
19580 CAN receive frame E2SCR (Dosing, Exh gas flow, Exh gas temp, Error Suppression, Heater, Long
Term failure) – 'too many CAN messages – 'P0600 Serial Communication Link
19581 CAN receive frame E2SCR (Dosing,Exh gas flow, Exh gas temp, Error Suppression, Heater, Long
Term failure) – SAE J1939 Check for CAN receive signal – P0600 Serial Communication Link
19595 CAN receive frame EEC1 (Driver demand, eng speed, eng torque) – 'SAE J1939 Check for CAN
receive signal : (Engine torque not in range) – 'P0600 Serial Communication Link
84477609A 27/09/2011
A.50.A / 139
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
19596 CAN receive frame EEC1 (Driver demand, eng speed, eng torque) – 'SAE J1939 Check for CAN
receive signal : (Engine speed not in range) – 'P0600 Serial Communication Link
19597 CAN receive frame EEC1 (Driver demand, eng speed, eng torque) – timeout – P0600 Serial
Communication Link
19598 CAN receive frame EEC1 (Driver demand, eng speed, eng torque) – 'too many CAN messages –
'P0600 Serial Communication Link
19599 CAN receive frame EEC1 (Driver demand, eng speed, eng torque) – 'SAE J1939 Check for CAN
receive signal : (Torque driver demand not in range) – 'P0600 Serial Communication Link
19604 CAN receive frame ET1 (Oil and Water temp engine) – 'SAE J1939 Check for CAN receive signal :
(Oil temperature not in range) – 'P0600 Serial Communication Link
19605 CAN receive frame ET1 (Oil and Water temp engine) – timeout – P0600 Serial Communication Link
19606 CAN receive frame ET1 (Oil and Water temp engine) – 'too many CAN messages – 'P0600 Serial
Communication Link
19607 CAN receive frame ET1 (Oil and Water temp engine) – 'SAE J1939 Check for CAN receive signal :
(Water temperature not in range) – 'P0600 Serial Communication Link
19649 UREA Tank level error (CAN message or electrical with real sensor) – 'Level over CAN: SAE J1939
no Signal available Level sensor connected directly: Sensor Supply error – 'P203A Reagent - tank
level sensor - open circuit
19650 UREA Tank level error (CAN message or electrical with real sensor) – Level over CAN: SAE J1939
Signal Not in Range Level sensor connected directly: SRC high – P203D Reagent - tank level
sensor - short circuit high
19651 UREA Tank level error (CAN message or electrical with real sensor) – 'Level over CAN: SAE J1939
Erroneous Signal Level sensor connected directly: SRC low – 'P203C Reagent - tank level sensor -
short circuit low
19652 UREA Tank level error (CAN message or electrical with real sensor) – (TIMEOUT)
19653 UREA Tank level error (CAN message or electrical with real sensor) – Level over CAN: SAE J1939
Erraneous Signal Level sensor connected directly: SRC low – P203C Reagent - tank level sensor
(too many CAN messages)
19654 UREA Tank level error (CAN message or electrical with real sensor) – Level over CAN: SAE
J1939 Erraneous Signal Level sensor connected directly: SRC low – P203A Reagent - tank level
sensor - Open circuit
19676 Ambient Temperature: SAE J1939 Check for CAN receive signal : (Signal Range Check: Signal not
in range / Erroneous Signal / Signal not available) – 'SAE J1939 Check for CAN receive signal :
(Ambient air temperature not in range) – 'P0600 Serial Communication Link
19677 Ambient Temperature: SAE J1939 Check for CAN receive signal : (Signal Range Check: Signal
not in range / Erroneous Signal / Signal not available) – timeout – P0071 Ambient Air Temperature
Sensor Range/Performance
19678 Ambient Temperature: SAE J1939 Check for CAN receive signal : (Signal Range Check: Signal not
in range / Erroneous Signal / Signal not available) – 'too many CAN messages – 'P0071 Ambient
Air Temperature Sensor Range/Performance
19679 Ambient Temperature: SAE J1939 Check for CAN receive signal : (Signal Range Check: Signal not
in range / Erroneous Signal / Signal not available) – 'SAE J1939 Check for CAN receive signal :
(Barometric pressure not in range) – 'P0071 Ambient Air Temperature Sensor Range/Performance
19721 EEPROM / Checksum failures – 'EEPROM write error – 'P062F Internal Control Module EEPROM
Error
19722 EEPROM / Checksum failures – 'No corresponding variant number error – 'P062F Internal Control
Module EEPROM Error
19723 EEPROM / Checksum failures – 'EEPROM communication error – 'P062F Internal Control Module
EEPROM Error
19724 EEPROM / Checksum failures – EEPROM Detection error OR 'Codierwort error – 'P062F Internal
Control Module EEPROM Error
19725 EEPROM / Checksum failures – 'Wrong EEPROM size – 'P062F Internal Control Module EEPROM
Error
19730 Ignition "on" signal K15 – 'digital input ignition ON not sensed during initialisation – 'P2530 Ignition
switch - plausibility error
19739 Main Relay opens too early / too late – 'main relay shut off too late – 'P0687 ECM/PCM Power
Relay Control Circuit High
84477609A 27/09/2011
A.50.A / 140
HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - ELECTRONIC SYSTEM
Code Description
19740 Main Relay opens too early / too late – 'main relay short circuit – 'P0685 ECM/PCM Power Relay
Control Circuit /Open
19741 Main Relay opens too early / too late – 'main relay open circuit – 'P0687 ECM/PCM Power Relay
Control Circuit High
19742 Main Relay opens too early / too late – main relay shut off too early (before EEPROM update) –
P0685 ECM/PCM Power Relay Control Circuit /Open
19748 Too high UREA Temperature in Pump module or Leakage test failed (Emergency shut off) – over
temperature detection (urea temp. in pump module) – P2043 Reagent - temperature sensor of
pump module - Out of range
19802 UREA Tank Temperature not plausible with pump module temperature - Temp over CAN: SAE J1939
Timeout Temp sensor connected directly SRC high - P0600 Serial Communication Link
19803 UREA Tank Temperature not plausible with pump module temperature - Temp over CAN: SAE J1939
- Too many messages Temp sensor connected directly SRC low - P0600 Serial Communication Link
19804 UREA Tank Temperature not plausible with pump module temperature - Temp over CAN: SAE
J1939 erroneous signal - P205A Reagent - tank temperature sensor (temperature of the Reagent -
solution in tank) - Open circuit
19805 UREA Tank Temperature not plausible with pump module temperature - SRC High - raw value UREA
temperature too high - P205D Reagent - tank temperature sensor (temperature of the Reagent -
solution in the tank) - Short circuit high
19806 UREA Tank Temperature not plausible with pump module temperature - SRC Low - raw value UREA
temperature too low - P205C Reagent - tank temperature sensor (temperature of the Reagent -
solution in the tank) - Short circuit low
19807 UREA Tank Temperature not plausible with pump module temperature - SRC High - diagnostic
value UREA temperature too high - P205B Reagent - tank temperature sensor (temperature of the
Reagent - solution in the tank) - Out of range
19808 UREA Tank Temperature not plausible with pump module temperature - SRC Low - diagnostic
value UREA temperature too low - P205B Reagent - tank temperature sensor (temperature of the
Reagent - solution in the tank) - Out of range
19813 Startup cycle for pressure drop dosing - P208B Reagent pump - Not delivering
19817 Plausibility of UDV stuck - P202F - Reagent dosing valve - Blocked (only stuck closed)
19818 Plausibility of UDV stuck - P202D - Dynamic urea leakage test - Leakage detected
19822 UDV valve stuck position unknown error - P202D Dynamic urea leakage test - Leakage detected
19999 Unknown DeNOX fault code
84477609A 27/09/2011