VARIABLE REFRIGERANT FLOW
AIR SOURCE HEAT PUMP TYPE
HNBQ SERIES
–
Company Name
– –
CUSTOMER SERVICE CERTIFICATION
–
SALES OFFICE
–
SPARE PARTS –
WARRANTY
–
DISTRIBUTOR
–
SOCIAL MEDIA
1810-C-HNBQ-1
– –
Air. It’s a
This is our vision. We call this ‘Living Harmony’ and it’s at the
To create the air that makes life better. center of everything we do.
–
The future together
Living Harmony puts people first. By balancing
the human needs of our customers with an
uncompromising approach to innovation
and quality, we can continue to create the
WELCOME
technologies for a more comfortable and
balanced world.
01
02
– –
Your world
Design for tomorrow’s
urban spaces.
and Hitachi
Space in our cities is under increasing
pressure and as new buildings become
more space efficient, the areas allocated
to cooling and heating are shrinking.
We are responding to these changes with
a new generation of space-efficient
outdoor units, giving architects,
building managers and owners greater
levels of flexibility.
– –
Change in the air. Redefining comfort.
Change is one of the few constants in life.
Comfort can be felt in a variety of ways, from the
The world around us changes continuously and as it does, so do our own
temperature to quietness and even the air flow
comfort levels and our requirements of our buildings.
itself. Our wide-ranging lineup of indoor units can
meet various comfort requirements. We offer two
Creating harmony in the face of change has always been the driving force
different types of ventilation units, and optional
behind Hitachi Cooling & Heating. From maintaining a perfect indoor climate
motion sensors are also available for superior
indoors as the seasons change, to developing new technology to address the
energy saving.
needs of our changing cities, we’re committed to solutions that help people
–
You are in control.
Whether you wish to create a relaxing
atmosphere in your home, improve
productivity at work or manage the
energy and maintenance costs for your
building, We give you the technology
to achieve your goals. From setting
individual climate zones in every room,
to centralized monitoring and reporting
for multiple buildings.
–
Learn more about Controller
on page 53 03
04
–
INDEX
07 OUTDOOR UNITS
INDEX
39 DUCTED FSNQ series
45 EXPOSED & CONCEALED
49 VENTILATION
51 OPTIONAL PARTS
52 INTRODUCTION OF MOTION SENSOR KIT
53 CONTROLLERS
55 LINE UP OVERVIEW
57 INDIVIDUAL CONTROLLERS
63 CENTRALIZED CONTROLLERS
73 H-LINK
75 OTHERS
77 OUR HERITAGE 05
06
–
Raising
the standard
07
08
–
LINE UP OVERVIEW
The HNBQ Series is newly launched with a wide range of models in its lineup,
as well as a variety of performance enhancements in design,
power and economy. Select the product(s) most suitable for your application,
either as a single unit or a combination of single units.
(HP Class / Cooling Capacity / Heating Capacity / Net Weight)
Single module
1,725mm
1,725mm
1,725mm
1,725mm
1,725mm
1,725mm
4,824mm 782mm 5,262mm 782mm 5,652mm 782mm
958mm 782mm 1,218mm 782mm 1,608mm 782mm
8HP Class / 22.4kW / 25.0kW / 248kg 12HP Class / 33.5kW / 37.5kW / 308kg 18HP Class / 50.0kW / 56.0kW / 390kg 54HP Class / 150.0kW / 168.0kW / 1,170kg 62HP Class / 175.0kW / 196.0kW / 1,458kg 64HP Class / 180.0kW / 202.0kW / 1,492kg
10HP Class / 28.0kW / 31.5kW / 248kg 14HP Class / 40.0kW / 45.0kW / 356kg 20HP Class / 56.0kW / 63.0kW / 415kg 56HP Class / 156.0kW / 175.0kW / 1,195kg 66HP Class / 185.0kW / 207.0kW / 1,492kg
16HP Class / 45.0kW / 50.0kW / 356kg 22HP Class / 61.5kW / 69.0kW / 416kg 58HP Class / 162.0kW / 182.0kW / 1,220kg
60HP Class / 168.0kW / 189.0kW / 1,245kg Whole range
up to 88HP class!
1,725mm
1,725mm
1,725mm
1,725mm
1,725mm
LINE UP OVERVIEW
6,042mm 782mm 6,432mm 782mm
2,436mm 782mm 2,826mm 782mm 3,216mm 782mm
24HP Class / 67.0kW / 75.0kW / 616kg 34HP Class / 95.0kW / 106.0kW / 746kg 36HP Class / 100.0kW / 112.0kW / 780kg 68HP Class / 190.0kW / 213.0kW / 1,526kg 72HP Class / 200.0kW / 224.0kW / 1,560kg 82HP Class / 229.5kW / 258.0kW / 1,661kg
26HP Class / 73.5kW / 82.5kW / 664kg 38HP Class / 106.0kW / 119.0kW / 805kg 70HP Class / 195.0kW / 218.0kW / 1,526kg 74HP Class / 206.0kW / 231.0kW / 1,585kg 84HP Class / 235.0kW / 264.0kW / 1,662kg
28HP Class / 80.0kW / 90.0kW / 712kg 40HP Class / 112.0kW / 126.0kW / 830kg 76HP Class / 212.0kW / 238.0kW / 1,610kg 86HP Class / 240.5kW / 270.0kW / 1,663kg
30HP Class / 85.0kW / 95.0kW / 712kg 78HP Class / 218.0kW / 245.0kW / 1,635kg 88HP Class / 246.0kW / 276.0kW / 1,664kg
32HP Class / 90.0kW / 100.0kW / 712kg 80HP Class / 224.0kW / 252.0kW / 1,660kg
SUMMARY TABLE
Item Unit HNBQ Series
HP class 8- 88
Capacity Nominal Cooling kW 22.4 - 246.0
Nominal Heating kW 25.0 - 276.0
Maximum connectable indoor unit quantity 14 - 64
1,725mm
1,725mm
Inverter Compressor
Inverter Compressor
Control Capacity
Control Capacity
3.0
DC inverter compressor, with outstandingly
2.0 precise control technology of 0.1Hz
5.0
4.90 4.70 4.90 4.76
4.35 4.41
4.06 3.88
4.0
3.0
2.0
2) HEAT EXCHANGER
1.0
0.0
• The heat exchange area has been increased by more than 10% (single module)
8 10 12 14 16 18 20 22 HP Class • Greater heat exchange efficiency
Split left-right
New shape heat exchanger
Improved angle
Notes: of the curve
1. The cooling and heating capacities above show the maximum capacities when the outdoor
Σ shape !
HIGH EFFICIENCY
and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB)
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre
WHAT'S IMPROVED? 1) COMPRESSOR 2) HEAT EXCHANGER 3) AIR OUTLET Current model (single module) New single medium & Large cabinet Current model (single module) New single medium & Large cabinet
3) AIR OUTLET
• Improvement of airflow volume by 23
% (single module)
• Energy consumption in the driving shaft has decreased by 20% on average
Expansion of air outlet Improvement in air outlet
Air outlets area Smoother air flow
+ 40 %
Narrower
Longer
New (Twin-fan)
121
0m
m Less short
Air volume area………6334cm2
circuit !! 11
Current model New model Current model New model 12
–
DESIGN FLEXIBILITY
Can be transported
DESIGN FLEXIBILITY
PIPING CONNECTION WORKABILITY Piping connection kit 1st Branch Multi kit OPERATION TEMPERATURE RANGE
• Suitable for a high- rise building or complex facilities. Enhanced performance in consideration of the actual installation environment of the outdoor unit
• Leads to cost/time saving for designers, with more efficient design.
Gas pipe Liquid pipe Gas pipe Liquid pipe
Cooling Operation
Maximum piping length
Unit
Total piping length m 1,000
52
Actual m 165
Refrigerant piping length Interval Operation Working Range
The model calculates the appropriate amount of refrigerant supplied by the outdoor units on the basis and distribute the load by rotating the order of operation of the compressors of the outdoor units.
of information about the required load from the individual indoor units. The model employs smooth
operation control to control the number of revolutions of the inverter compressor. The model supplies
the appropriate amount of refrigerant to the indoor units according to the required load. The model
increases energy-saving efficiency by operating smoothly while controlling the switching on and off of
Rotation
Inverter on on off on off on
compressor Indoor Unit Indoor Unit
Transmit Transmit
load load
Outdoor Unit information information
ADAPTABILITY
Transmission Wire (Conceptual Drawing)
Room Temperature(°C)
Room Temperature(°C)
Power consumption(kW)
Power consumption(kW)
due to
frequent switching -39%
energy consumed
on/off operation
15
16
–
SPECIFICATIONS
HP class 8HP class 10HP class 12HP class 14HP class 16HP class 18HP class 20HP class 22HP class 24HP class
Model RAS-8.0HNBBMQ RAS-10HNBBMQ RAS-12HNBBMQ RAS-14HNBBMQ RAS-16HNBBMQ RAS-18HNBBMQ RAS-20HNBBMQ RAS-22HNBBMQ RAS-24HNBBMQ
SPECIFICATIONS
Gas mm φ25.4(1) φ25.4(1) φ25.4(1) φ28.58(1-1/8) φ28.58(1-1/8) φ28.58(1-1/8) φ28.58(1-1/8) φ28.58(1-1/8) φ31.75(1-1/4)
Max A 27.0 27.0 31.5 43.5 43.5 45.0 52.0 61.5 31.5+31.5
Breaker A 32 32 40 63 63 63 63 80 40+40
Current
Cooling A 8.4 11.9 14.6 17.0 19.9 23.4 27.1 33.2 14.6+14.6
Heating A 8.9 11.7 13.5 15.8 19.4 23.0 27.2 33.0 13.5+13.5
EER W/W 4.62 4.10 4.09 4.02 3.91 3.77 3.62 3.68 4.09
Efficiency
COP W/W 4.90 4.70 4.90 4.76 4.35 4.41 4.06 3.88 4.90
The max IDU connect qty. 14 17 21 24 28 31 35 38 42
Cooling Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB
Working temp. range
Heating Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB
Refrigerant control mode electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve
Tubing connection method Welding connection Welding connection Welding connection
Total piping length m 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
Actual m 165 165 165 165 165 165 165 165 165
Refrigerant piping length
Maximum Equivalent m 190 190 190 190 190 190 190 190 190
piping
length Between "Piping connection kit" and each outdoor unit m 10 10 10 10 10 10 10 10 10
Between "1st branch Multi Kit" and farthest indoor unit m 90(*1) 90 90 90 90 90 90 90 90
Between "Multi Kit" and each indoor unit m 40 40 40 40 40 40 40 40 40
Between outdoor units (combination of base units) m 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
50 (standard) / up to 1150 (standard) / 50 (standard) / up to 1150 (standard) / 50 (standard) / up to 1150 (standard) /
Maximum ODU above IDU(*) m
Between outdoor unit and indoor up to 110m (custom order)(*2)0m (custom order)(*2) up to 110m (custom order)(*2)0m (custom order)(*2) up to 110m (custom order)(*2)0m (custom order)(*2)
level
units
difference
IDU above ODU m 40 40 40 40 40 40 40 40 40
Notes:
1. The cooling and heating performances are the values when combined with our test indoor units. 2. The sound pressure is based on the following conditions. (*) Standard: up to 50 metre/Custom Order: up to 110 metre.
Cooling Operation Conditions Heating Operation Conditions 1 metre from the unit service cover surface, and 1.36 metre from floor level. Longer piping (up to 110 metre) is available for 8 to 48HP class models only.
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) The above data is based on the cooling mode. In case of heating mode, the sound pressure Maximum level difference for 50 to 88HP class is 90 metre.
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) level increases by approximately 1~2 dB(A). The above data was measured in a semi-anechoic
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) chamber so that reflected sound should be taken into consideration in the field. 17
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre 18
–
SPECIFICATIONS
HP class 26HP class 28HP class 30HP class 32HP class 34HP class 36HP class 38HP class 40HP class 42HP class
Combination of single module unit 12+14 14+14 14+16 16+16 16+18 18+18 18+20 20+20 14+14+14
Model RAS-26HNBBMQ RAS-28HNBBMQ RAS-30HNBBMQ RAS-32HNBBMQ RAS-34HNBBMQ RAS-36HNBBMQ RAS-38HNBBMQ RAS-40HNBBMQ RAS-42HNBBMQ
SPECIFICATIONS
Gas mm φ31.75(1-1/4) φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2)
Max A 31.5+43.5 43.5+43.5 43.5+43.5 43.5+43.5 43.5+45.0 45.0+45.0 45.0+52.0 52.0+52.0 43.5+43.5+43.5
Breaker A 40+63 63+63 63+63 63+63 63+63 63+63 63+63 63+63 63+63+63
Current
Cooling A 14.6+17.0 17.0+17.0 17.0+19.9 19.9+19.9 19.9+23.4 23.4+23.4 23.4+27.1 27.1+27.1 17.0+17.0+17.0
Heating A 13.5+15.8 15.8+15.8 15.8+19.4 19.4+19.4 19.4+23.0 23.0+23.0 23.0+27.2 27.2+27.2 15.8+15.8+15.8
EER W/W 4.05 4.02 3.96 3.91 3.84 3.77 3.69 3.62 4.02
Efficiency
COP W/W 4.82 4.76 4.53 4.35 4.38 4.41 4.22 4.06 4.76
The max IDU connect qty. 45 49 52 56 59 63 64 64 64
Cooling Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB
Working temp. range
Heating Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB
Refrigerant control mode electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve
Tubing connection method Welding connection Welding connection Welding connection
Total piping length m 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
Actual m 165 165 165 165 165 165 165 165 165
Refrigerant piping length
Maximum Equivalent m 190 190 190 190 190 190 190 190 190
piping
length Between "Piping connection kit" and each outdoor unit m 10 10 10 10 10 10 10 10 10
Between "1st branch Multi Kit" and farthest indoor unit m 90 90 90 90 90 90 90 90 90
Between "Multi Kit" and each indoor unit m 40 40 40 40 40 40 40 40 40
Between outdoor units (combination of base units) m 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
50 (standard) 50 (standard) 50 (standard)
Maximum ODU above IDU(*) m
Between outdoor unit and indoor up to 110 (custom order) up to 110 (custom order) up to 110 (custom order)
level
units
difference
IDU above ODU m 40 40 40 40 40 40 40 40 40
Notes:
1. The cooling and heating performances are the values when combined with our test indoor units. 2. The sound pressure is based on the following conditions. (*) Standard: up to 50 metre/Custom Order: up to 110 metre.
Cooling Operation Conditions Heating Operation Conditions 1 metre from the unit service cover surface, and 1.36 metre from floor level. Longer piping (up to 110 metre) is available for 8 to 48HP class models only.
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) The above data is based on the cooling mode. In case of heating mode, the sound pressure Maximum level difference for 50 to 88HP class is 90 metre.
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) level increases by approximately 1~2 dB(A). The above data was measured in a semi-anechoic
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) chamber so that reflected sound should be taken into consideration in the field. 19
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre 20
–
SPECIFICATIONS
HP class 44HP class 46HP class 48HP class 50HP class 52HP class 54HP class 56HP class 58HP class 60HP class
Combination of single module unit 14+14+16 14+16+16 16+16+16 16+16+18 16+18+18 18+18+18 18+18+20 18+20+20 20+20+20
Model RAS-44HNBBMQ RAS-46HNBBMQ RAS-48HNBBMQ RAS-50HNBBMQ RAS-52HNBBMQ RAS-54HNBBMQ RAS-56HNBBMQ RAS-58HNBBMQ RAS-60HNBBMQ
SPECIFICATIONS
Gas mm φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2) φ44.5(1-3/4) φ44.5(1-3/4) φ44.5(1-3/4) φ44.5(1-3/4) φ44.5(1-3/4) φ44.5(1-3/4)
Max A 43.5+43.5+43.5 43.5+43.5+43.5 43.5+43.5+43.5 43.5+43.5+45.0 43.5+45.0+45.0 45.0+45.0+45.0 45.0+45.0+52.0 45.0+52.0+52.0 52.0+52.0+52.0
Breaker A 63+63+63 63+63+63 63+63+63 63+63+63 63+63+63 63+63+63 63+63+63 63+63+63 63+63+63
Current
Cooling A 17.0+17.0+19.9 17.0+19.9+19.9 19.9+19.9+19.9 19.9+19.9+23.4 19.9+23.4+23.4 23.4+23.4+23.4 23.4+23.4+27.1 23.4+27.1+27.1 27.1+27 .1+27.1
Heating A 15.8+15.8+19.4 15.8+19.4+19.4 19.4+19.4+19.4 19.4+19.4+23.0 19.4+23.0+23.0 23.0+23.0+23.0 23.0+23.0+27.2 23.0+27.2+27.2 27.2+27.2+27.2
EER W/W 3.98 3.95 3.91 3.86 3.82 3.77 3.72 3.67 3.62
Efficiency
COP W/W 4.61 4.47 4.35 4.37 4.39 4.41 4.28 4.16 4.06
The max IDU connect qty. 64 64 64 64 64 64 64 64 64
Cooling Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB
Working temp. range
Heating Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB
Refrigerant control mode electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve
Tubing connection method Welding connection Welding connection Welding connection
Total piping length m 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
Actual m 165 165 165 165 165 165 165 165 165
Refrigerant piping length
Maximum Equivalent m 190 190 190 190 190 190 190 190 190
piping
length Between "Piping connection kit" and each outdoor unit m 10 10 10 10 10 10 10 10 10
Between "1st branch Multi Kit" and farthest indoor unit m 90 90 90 90 90 90 90 90 90
Between "Multi Kit" and each indoor unit m 40 40 40 40 40 40 40 40 40
Between outdoor units (combination of base units) m 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
50 (standard) 50 (standard) 50 (standard)
Maximum ODU above IDU(*) m
Between outdoor unit and indoor up to 110 (custom order) up to 90 (custom order) up to 90 (custom order)
level
units
difference
IDU above ODU m 40 40 40 40 40 40 40 40 40
Notes:
1. The cooling and heating performances are the values when combined with our test indoor units. 2. The sound pressure is based on the following conditions. (*) Standard: up to 50 metre/Custom Order: up to 110 metre.
Cooling Operation Conditions Heating Operation Conditions 1 metre from the unit service cover surface, and 1.36 metre from floor level. Longer piping (up to 110 metre) is available for 8 to 48HP class models only.
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) The above data is based on the cooling mode. In case of heating mode, the sound pressure Maximum level difference for 50 to 88HP class is 90 metre.
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) level increases by approximately 1~2 dB(A). The above data was measured in a semi-anechoic
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) chamber so that reflected sound should be taken into consideration in the field. 21
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre 22
–
SPECIFICATIONS
HP class 62HP class 64HP class 66HP class 68HP class 70HP class 72HP class 74HP class 76HP class 78HP class
Combination of single module unit 14+14+16+18 14+14+18+18 14+16+18+18 14+18+18+18 16+18+18+18 18+18+18+18 18+18+18+20 18+18+20+20 18+20+20+20
Model RAS-62HNBBMQ RAS-64HNBBMQ RAS-66HNBBMQ RAS-68HNBBMQ RAS-70HNBBMQ RAS-72HNBBMQ RAS-74HNBBMQ RAS-76HNBBMQ RAS-78HNBBMQ
SPECIFICATIONS
Gas mm φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2)
Max A 43.5+43.5+43.5+45.0 43.5+43.5+45.0+45.0 43.5+43.5+45.0+45.0 43.5+45.0+45.0+45.0 43.5+45.0+45.0+45.0 45.0+45.0+45.0+45.0 45.0+45.0+45.0+52.0 45.0+45.0+52.0+52.0 45.0+52.0+52.0+52.0
Breaker A 63+63+63+63 63+63+63+63 63+63+63+63 63+63+63+63 63+63+63+63 63+63+63+63 63+63+63+63 63+63+63+63 63+63+63+63
Current
Cooling A 17.0+17.0+19.9+23.4 17.0+17.0+23.4+23.4 17.0+19.9+23.4+23.4 17.0+23.4+23.4+23.4 19.9+23.4+23.4+23.4 23.4+23.4+23.4+23.4 23.4+23.4+23.4+27.1 23.4+23.4+27.1+27.1 23.4+27.1+27.1+27.1
Heating A 15.8+15.8+19.4+23.0 15.8+15.8+23.0+23.0 15.8+19.4+23.0+23.0 15.8+23.0+23.0+23.0 19.4+23.0+23.0+23.0 23.0+23.0+23.0+23.0 23.0+23.0+23.0+27.2 23.0+23.0+27.2+27.2 23.0+27.2+27.2+27.2
EER W/W 3.92 3.88 3.86 3.82 3.80 3.77 3.73 3.69 3.66
Efficiency
COP W/W 4.55 4.56 4.47 4.48 4.40 4.41 4.31 4.22 4.14
The max IDU connect qty. 64 64 64 64 64 64 64 64 64
Cooling Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB
Working temp. range
Heating Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB
Refrigerant control mode electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve
Tubing connection method Welding connection Welding connection Welding connection
Total piping length m 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
Actual m 165 165 165 165 165 165 165 165 165
Refrigerant piping length
Maximum Equivalent m 190 190 190 190 190 190 190 190 190
piping
length Between "Piping connection kit" and each outdoor unit m 10 10 10 10 10 10 10 10 10
Between "1st branch Multi Kit" and farthest indoor unit m 90 90 90 90 90 90 90 90 90
Between "Multi Kit" and each indoor unit m 40 40 40 40 40 40 40 40 40
Between outdoor units (combination of base units) m 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
50 (standard) 50 (standard) 50 (standard)
Maximum ODU above IDU(*) m
Between outdoor unit and indoor up to 90 (custom order) up to 90 (custom order) up to 90 (custom order)
level
units
difference
IDU above ODU m 40 40 40 40 40 40 40 40 40
Notes:
1. The cooling and heating performances are the values when combined with our test indoor units. 2. The sound pressure is based on the following conditions. (*) Standard: up to 50 metre/Custom Order: up to 110 metre.
Cooling Operation Conditions Heating Operation Conditions 1 metre from the unit service cover surface, and 1.36 metre from floor level. Longer piping (up to 110 metre) is available for 8 to 48HP class models only.
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) The above data is based on the cooling mode. In case of heating mode, the sound pressure Maximum level difference for 50 to 88HP class is 90 metre.
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) level increases by approximately 1~2 dB(A). The above data was measured in a semi-anechoic
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) chamber so that reflected sound should be taken into consideration in the field. 23
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre 24
–
SPECIFICATIONS
HP class 80HP class 82HP class 84HP class 86HP class 88HP class
SPECIFICATIONS
Gas mm φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2)
Max A 52.0+52.0+52.0+52.0 52.0+52.0+52.0+61.5 52.0+52.0+61.5+61.5 52.0+61.5+61.5+61.5 61.5+61.5+61.5+61.5
Breaker A 63+63+63+63 63+63+63+80 63+63+80+80 63+80+80+80 80+80+80+80
Current
Cooling A 27.1+27.1+27.1+27.1 27.1+27.1+27.1+33.2 27.1+27.1+33.2+33.2 27.1+33.2+33.2+33.2 33.2+33.2+33.2+33.2
Heating A 27.2+27.2+27.2+27.2 27.2+27.2+27.2+33.0 27.2+27.2+33.0+33.0 27.2+33.0+33.0+33.0 33.0+33.0+33.0+33.0
EER W/W 3.62 3.64 3.65 3.67 3.68
Efficiency
COP W/W 4.06 4.01 3.96 3.92 3.88
The max IDU connect qty. 64 64 64 64 64
Cooling Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB
Working temp. range
Heating Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB
Refrigerant control mode electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve
Tubing connection method Welding connection Welding connection
Total piping length m 1,000 1,000 1,000 1,000 1,000
Actual m 165 165 165 165 165
Refrigerant piping length
Maximum Equivalent m 190 190 190 190 190
piping
length Between "Piping connection kit" and each outdoor unit m 10 10 10 10 10
Between "1st branch Multi Kit" and farthest indoor unit m 90 90 90 90 90
Between "Multi Kit" and each indoor unit m 40 40 40 40 40
Between outdoor units (combination of base units) m 0.1 0.1 0.1 0.1 0.1
50 (standard) 50 (standard)
Maximum ODU above IDU(*) m
Between outdoor unit and indoor up to 90 (custom order) up to 90 (custom order)
level
units
difference
IDU above ODU m 40 40 40 40 40
Notes:
1. The cooling and heating performances are the values when combined with our test indoor units. 2. The sound pressure is based on the following conditions. (*) Standard: up to 50 metre/Custom Order: up to 110 metre.
Cooling Operation Conditions Heating Operation Conditions 1 metre from the unit service cover surface, and 1.36 metre from floor level. Longer piping (up to 110 metre) is available for 8 to 48HP class models only.
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) The above data is based on the cooling mode. In case of heating mode, the sound pressure Maximum level difference for 50 to 88HP class is 90 metre.
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) level increases by approximately 1~2 dB(A). The above data was measured in a semi-anechoic
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) chamber so that reflected sound should be taken into consideration in the field. 25
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre 26
–
OPTIONAL PARTS
ID34.92
MULTI-KIT
1) 1st branch Multi-kit
Main Piping ≥ 100m Main Piping < 100m Example: E-462SN
Model Outdoor unit capacity Model Outdoor unit capacity
Gas side Liquid side Reducer
E-242SN 8-12HP class E-162SN 8-12HP class
ID44.5 ID9.53
ID9.53 ID9.53 Ø44.5 Ø44.5Ø44.5 ID28.6
ID28.6 ID28.6
E-302SN 14-22HP class E-242SN 14-22HP class ID41.3
ID41.3 ID41.3 ID44.5 ID44.5 ID22.2
ID22.2
ID22.2ID12.7
ID12.7
ID12.7
ID44.5
ID44.5 ID44.5 ID41.3
ID41.3 ID41.3 ID19.05 ID25.4
ID25.4 ID25.4
E-462SN 24-48HP class E-302SN 24-48HP class ID19.05 ID19.05ID15.88
ID15.88 ID15.88
ID38.1
ID38.1 ID31.75
ID38.1 ID31.75 ID31.75
E-682SN 50-88HP class E-462SN 50-60HP class ID19.05
ID19.05 ID19.05
Ø41.3Ø41.3
Ø41.3 Ø41.3Ø41.3Ø25.4
Ø41.3 Ø25.4Ø25.4 ID22.2 Ø28.6Ø28.6 ID15.88
ID15.88 ID15.88
ID22.2 Ø28.6
ID22.2 ID12.7 ID25.4
ID25.4 ID
E-682SN 62-88HP class Ø19.05
Ø19.05 Ø19.05 Ø25.4 Ø25.4Ø25.4 ID12.7 ID12.7
Ø38.1Ø38.1 ID31.75
Ø38.1 ID31.75
ID31.75 ID15.88 ID9.53
ID15.88ID15.88 ID9.53 ID9.53
ID38.1
ID38.1 ID38.1 ID12.7 ID6.35
OPTIONS
ID28.6 ID12.7 ID12.7 ID6.35 ID6.35ID22.2
ID22.2 ID19.05
ID22.2 ID19.05 ID19.05
ID28.6 ID28.6
ID44.5 ID9.53 Ø44.5 ID28.6
ID41.3 ID22.2 ID12.7
2) Multi-kit after 1st branch and pipe diameter ID44.5 ID41.3 ID19.05 ID15.88 ID25.4
Diameter (mm) ID38.1 ID31.75
Q= ID19.05
Model Ø41.3 Ø41.3 Ø25.4 ID22.2 Ø28.6 ID15.88
Total indoor unit capacity (kW) Gas Pipe Liquid Pipe ID25.4
Ø19.05 Ø25.4 ID12.7
Ø38.1 ID31.75 ID15.88 ID9.53
Q ≤ 15.9 15.88 9.52 ID38.1
ID12.7 ID6.35 ID22.2 ID19.05
ID28.6
E-102SN 16 ≤ Q < 25 19.05 9.52
25 ≤ Q < 33.5 22.2 9.52
33.5 ≤ Q < 45 25.4 12.7
E-162SN
45 ≤ Q < 50 28.58 12.7
E-242SN 50 ≤ Q < 72.9 28.58 15.88
72.9 ≤ Q < 100.8 31.75 19.05
E-302SN
100.8 ≤ Q < 156.8 38.1 19.05
156.8 ≤ Q < 190.4 44.45 19.05
E-462SN
190.4 ≤ Q < 207.2 44.45 22.2
207.2 ≤ Q < 252 50.8 22.2
E-682SN 252 ≤ Q < 274.4 50.8 25.4
274.4 ≤ Q < 349.5 50.8 28.58
27
28
–
Indoor life
29
30
–
LINE UP OVERVIEW
4-WAY CASSETTE
CEILING CASSETTE
4-WAY CASSETTE TYPE 4-WAY CASSETTE COMPACT TYPE 2-WAY CASSETTE TYPE 1-WAY CASSETTE TYPE
COMPACT TYPE ∙ With area of air distribution with ∙ Dimensions correspond with ∙ Motion sensor available for better ∙ Motion sensor available for better
DUCTED
MEDIUM ESP TYPE
HIGH ESP TYPE MEDIUM ESP TYPE LOW ESP TYPE SLIM TYPE COMPACT TYPE
∙ High ESP (90/120Pa for 3.0-6.0 HP ∙ 2 steps of medium ESP (50/80Pa ∙ Low ESP (30Pa for 0.8-2.5 HP ∙ Ideal for narrow ceiling voids (BOTH AC MOTOR TYPE AND
class, 180Pa for 8.0-10.0 HP class) for 0.8- 2.5 HP class, 100Pa for class, 60Pa for 3.0-6.0 HP class) installation thanks to low height DC MOTOR TYPE AVAILABLE)
SLIM TYPE ∙ Space saving design thanks to a 8.0-10.0 HP class) ∙ Space saving design thanks to a up to 192mm & width just 700mm
∙ Ideal for installation over the
height of only 300mm (3.0 - 6.0 ∙ Space saving design thanks to a height of only 270mm (0.8-2.5HP ∙ Drain-pump with 900mm lift as
closet or windows thanks to
HP class) or 470mm (8.0-10.0HP height of only 270mm (0.8 - 2.5HP class) or 350mm (3.0-6.0HP class) standard optional part
the up to the compactness with
class) class) or 470mm (8.0 - 10.0HP ∙ Quiet operation level (as low as 22
192mm height
class) dB(A))
LINE UP OVERVIEW
∙ Drain-pump with 900mm lift as
COMPACT TYPE standard optional part
(BOTH AC MOTOR TYPE ∙ Quiet operation level (as low as
AND DC MOTOR TYPE 21dB(A))
AVAILABLE) ∙ Fan air flow rate up to 6 taps (DC
motor model only)
FLOOR
CONCEALED TYPE
CONCEALED & EXPOSED
FLOOR / CEILING
CONVERTIBLE TYPE
OTHERS
CEILING FLOOR CONCEALED TYPE FLOOR/CEILING CONVERTIBLE TYPE CEILING SUSPENDED TYPE WALL MOUNTED TYPE
SUSPENDED TYPE ∙ Visual aesthetics: it can be hidden ∙ Fully [Floor mounted] or ∙ Ideal for a higher ceiling location ∙ Simple installation procedure
away even when there is no ceiling [Ceiling suspended] installation for installation (up to 5.6m in ∙ Flexible discreet design suitable
void. Little installation space convertible cooling) to any interior
required thanks to only 220mm ∙ Easy installation ∙ Better power-saving with
WALL depth ∙ Fresh air-intake design optional Motion Sensor
MOUNTED TYPE ∙ Height just up to 620mm, suitable ∙ Optional drain pump available ∙ Quiet operation level (as low as
for installation beneath the 28dB(A)
window
COMPARING VENTILATIONS
COMPARING VENTILATIONS CAPACITY
Fan Air Flow Rate (m3/h) 200 300 400 500 650 800 1,000 1,080 1,250 1,500 1,680 2,000 2,100 2,500 3,000 4,000 5,000 6,000
ALL FRESH AIR UNIT
FEATURES COMPARISON
4-WAY 4-WAY 2-WAY 1-WAY HIGH/MEDIUM/ (8/10HP class) SLIM TYPE COMPACT TYPE COMPACT TYPE FLOOR FLOOR/CEILING CEILING WALL MOUNTED TYPE
CASSETTE CASSETTE CASSETTE CASSETTE LOW ESP TYPE HIGH/MEDIUM (AC) (DC) CONCEALED CONVERTIBLE SUSPENDED
TYPE COMPACT TYPE TYPE TYPE ESP TYPE TYPE TYPE TYPE
Model
RPIH-HNAUNQ
RPI-FSNQ
RCI-FSKDNQ RCIM-FSN4 RCD-FSN3 RCS-FSN RPIM-HNAUNQ RPIZ-FSNQS/P RPIZ-HNATNQ RPIZ-HNDTSQ RPFI-FSNQ RPFC-FSNQ RPC-FSN3 RPK-FSNQS RPK-FSN4M
RPI-FSN3Q
RPIL-HNAUNQ
Indoor Fan Speed 4 taps 4 taps 4 taps 4 taps 3 taps 1 tap 3 taps 3 taps 6 taps 3 taps 3 taps 4 taps 3 taps 4 taps
Louver Direction 7 (*4) 7 (*4) 7 (*4) 7 (*5) - - - - - - 7 (*5) 7 (*5) 7 (*5) 7 (*5)
Quick Function - - - - - - - -
LINE UP OVERVIEW
Power Consumption visualization - - - - - - - -
MENU
(*2) Weekly Schedule Setting
Power-Saving Setting - - - - - - - -
(*1) This function is utilized to prevent cold discharged air at start-up of heating (*6) 3 colors available except white (Beige, Grey and Black)
operation, after defrosting operation, etc. The fan speed automatically switches (*7) Optional parts: Duct Adapter is availbale. please consult your distributor.
from Slow to Low and then to the set fan speed. The fan operation might be
stopped for up to 2 minutes. At this time the louver is fixed horizontally. (*8) Please consult your distributor for the availability.
(*2) Advanced wired remote controller PC-ARF1 needs to be connected. (*9) PC-ARF1 or HCWA10NEGQ needs to be connected.
(*3) included as standard equipment (*10) Standard Receiver kit (PC-RLH11) is equipped with the unit in package as
standard optional part with Wireless Remote Controller (PC-LH3A)
(*4) 7 steps are avilable by individual louver setting. 5 steps only in the operation of
Cooling or Dry. (*11) Receiver Kit is installed in the unit as standard part. Please use Receiver Kit
(PC-ALHZ1) when receiver kit needs to be installed separately from unit.
(*5) 5 steps only in the operation of Cooling or Dry.
33
34
– –
4-WAY CASSETTE TYPE 4-WAY CASSETTE COMPACT TYPE
DIMENSIONS DIMENSIONS
P-AP56NAM 3kg
Decoration panel 6.5kg 950mm 950mm
620mm 620mm
950mm 950mm
CEILING CASSETTE
energy-saving can be achieved along each zone
requirement
Model RCI-1.0FSKDNQ RCI-1.5FSKDNQ RCI-2.0FSKDNQ RCI-2.5FSKDNQ RCI-3.0FSKDNQ RCI-4.0FSKDNQ RCI-5.0FSKDNQ RCI-6.0FSKDNQ Model RCIM-0.6FSN4 RCIM-0.8FSN4 RCIM-1.0FSN4 RCIM-1.5FSN4 RCIM-2.0FSN4 RCIM-2.5FSN4
Indoor Unit Power Supply AC 1Φ, 220-240V/50Hz, 220V/60Hz Indoor Unit Power Supply AC 1Φ, 230V 50Hz, 220-240V 50Hz, 220V 60Hz
Nominal Cooling kW 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0 Nominal Cooling kW 1.6 2.2 2.8 4.0 5.6 7.1
Capacity Heating kW 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0 Capacity Heating kW 1.9 2.5 3.2 4.8 6.3 8.5
Sound Pressure Sound Pressure
(Hi2/Hi/Me/Lo) dB(A) 33/30/28/27 35/31/30/27 37/32/30/27 42/36/32/28 42/36/32/28 48/43/39/33 48/45/40/35 48/46/41/37 (Hi2/Hi/Me/Lo) dB(A) 34/30/28/24.5 36/33/29/24.5 38/34/30/24.5 41/37/33/27.5 45/39/35/31 47/43/39/35
Level Level
Outer Dimension (H×W×D) mm 238×840×840 238×840×840 238×840×840 238×840×840 288×840×840 288×840×840 288×840×840 288×840×840 Outer Dimension (H×W×D) mm 280×570×570 280×570×570 280×570×570 280×570×570 280×570×570 280×570×570
Net Weight kg 20 21 21 22 26 26 26 26 Net Weight kg 16 16 16 16 17 17
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A Refrigerant R410A R410A R410A R410A R410A R410A
Indoor Fan Indoor Fan
(Hi2/Hi/Me/Lo) m3/min 15/13/11/9 21/17/14/11 22/17/14/11 27/23/18/14 27/23/18/14 37/31/24/20 37/33/26/21 37/35/28/22 (Hi2/Hi/Me/Lo) m3/min 10/8.5/7.5/6 11/9.5/8/6 12/10/8.5/6 13/11/9.5/7 15/12/10/8 16/14/12/10
Air Flow Rate Air Flow Rate
Connections Flare-Nut Connection (with flare Nuts) Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52
Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.21 0.21 0.21 0.21 0.25 0.25 0.25 0.25
Adaptable Panel Model P-AP56NAM (without Motion Sensor)
Adaptable Panel Model Included (without Motion Sensor) Color Neutral White
Color Neutral White Outer Dimension (H×W×D) mm 30×620×620
Outer Dimension (H×W×D) mm 40×950×950 Net Weight kg 3.0
Net Weight kg 6.5
NOTE:
Approximate Packing Volume m3 0.10 1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
NOTE: Cooling Operation Conditions Heating Operation Conditions
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions. Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
Cooling Operation Conditions Heating Operation Conditions 19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) Piping Length:7.5 metre Piping Length:7.5 metre
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) Piping Lift:0 metre Piping Lift:0 metre
Piping Length:7.5 metre Piping Length:7.5 metre 2. The sound pressure level is based on following conditions.
Piping Lift:0 metre Piping Lift:0 metre 1.5 metre Beneath the Unit.
2. The sound pressure level is based on following conditions. The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
1.5 metre Beneath the Unit.
35
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Decoration panel is included. 36
– –
2-WAY CASSETTE TYPE 1-WAY CASSETTE TYPE
DIMENSIONS DIMENSIONS
860mm 630mm
RCS-0.8~1.0 FSN 25kg
RCD-0.8~1.0 FSN3 23kg 900mm 720mm
CEILING CASSETTE
∙ Clipped ceiling (two-way) type
Model RCD-0.8FSN3 RCD-1.0FSN3 RCD-1.5FSN3 RCD-2.0FSN3 RCD-2.5FSN3 RCD-3.0FSN3 RCD-4.0FSN3 RCD-5.0FSN3 RCD-6.0FSN3 Model RCS-0.8FSN RCS-1.0FSN RCS-1.5FSN RCS-2.0FSN RCS-2.5FSN RCS-3.0FSN
Indoor Unit Power Supply AC 1Φ, 220-240V/50Hz, 220V/60Hz Indoor Unit Power Supply AC 1Φ, 220-240V/50Hz, 230V/50Hz, 220V/60Hz
Nominal Cooling kW 2.2 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0 Nominal Cooling kW 2.2 2.8 4.0 5.6 7.1 8.0
Capacity Heating kW 2.5 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0 Capacity Heating kW 2.5 3.2 4.8 6.3 8.5 9.0
Sound Pressure Sound Pressure
(Hi2/Hi/Me/Lo) dB(A) 30/29/28/27 31/29/28/27 37/34/31/30 39/36/33/30 42/39/36/33 45/42/38/33 43/40/37/34 47/44/41/35 48/45/42/39 (Hi2/Hi/Me/Lo) dB(A) 34/32/29/27 36/34/31/28 40/37/33/31 42/38/35/31 43/39/36/32 43/40/37/33
Level Level
Outer Dimension (H×W×D) mm 298×860×630 298×860×630 298×860×630 298×860×630 298×860×630 298×860×630 298×1,420×630 298×1,420×630 298×1,420×630 Outer Dimension (H×W×D) mm 235×900×720 235×900×720 235×900×720 235×900×720 235×1,210×720 235×1,210×720
Net Weight kg 23 23 25 25 25 25 39 39 39 Net Weight kg 25 25 26 26 33 33
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A Refrigerant R410A R410A R410A R410A R410A R410A
Indoor Fan 16.5/14.5 18.5/16.5 21/18.5/16 37/32.5/28.5 Indoor Fan
(Hi2/Hi/Me/Lo) m3/min 10/9/7.5/6.5 11/9.5/8.5/7 15/13/11.5/10 30/26.5/23/20 35/31/27/21 (Hi2/Hi/Me/Lo) m3/min 8.5/7.5/6.5/6 9.5/8.5/7.5/6.5 13/11.5/10/8.5 14.5/13/11/9.5 18.5/16.5/14.5/12.5 20/17.5/15.5/13
Air Flow Rate /12.5/10.5 /14.5/12.5 /12.5 /24 Air Flow Rate
Connections Flare-Nut Connection (with Flare Nuts) Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.24 0.24 0.24 0.24 0.24 0.24 0.36 0.36 0.36 Approximate Packing Volume m3 0.25 0.25 0.25 0.25 0.32 0.32
Adaptable Panel Model P-AP90DNA (for RCD- [0.8-3.0] FSN3) P-AP160DNA (for RCD- [4.0-6.0] FSN3) Adaptable Panel Model P-AP36CNA (for RCS-[0.8-1.0]FSN) P-AP56CNA (for RCS-[1.5-2.0]FSN) P-AP80CNA (for RCS-[2.5-3.0]FSN)
Color Neutral White Neutral White Color Neutral White Neutral White Neutral White
Outer Dimension (H×W×D) mm 30×1,100×710 30×1,660×710 Outer Dimension (H×W×D) mm 35×1,100×800 35×1,100×800 35×1,410×800
Net Weight kg 7.5 10.5 Net Weight kg 4.5 4.5 6.0
Approximate Packing Volume m3 0.13 0.20
NOTE:
NOTE: 1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions. Cooling Operation Conditions Heating Operation Conditions
Cooling Operation Conditions Heating Operation Conditions Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) 19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB)
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) Piping Length:7.5 metre Piping Length:7.5 metre
Piping Length:7.5 metre Piping Length:7.5 metre Piping Lift:0 metre Piping Lift:0 metre
Piping Lift:0 metre Piping Lift:0 metre 2. The sound pressure level is based on following conditions.
2. The sound pressure level is based on following conditions. 1.5 metre Beneath the Unit. 37
1.5 metre Beneath the Unit. The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. 38
– –
DUCTED HIGH ESP (EXTERNAL STATIC PRESSURE) TYPE
Sound Pressure
COMPACT TYPE (Hi/Me/Lo) dB(A) 42/39/34 42/39/34 43/39/34 44/41/37 48/42/37
Type HIGH ESP TYPE MEDIUM ESP TYPE LOW ESP TYPE SLIM TYPE
(AC MOTOR / DC MOTOR)
Level
Outer
RPIH-(3.0~6.0)HNAUNQ RPIM-(0.8~2.5)HNAUNQ RPIZ-(0.8~2.5)HNATNQ (H×W×D) mm 300×1,175×800 300×1,175×800 300×1,175×800 300×1,475×800 300×1,475×800
Model RPI-(8.0~10.0)FSNQ RPI-(8.0~10.0)FSN3Q
RPIL-(0.8~6.0)HNAUNQ RPIZ-(0.8~1.5)FSNQS/P
RPIZ-(0.8~2.5)HNDTSQ
Dimension
Cooling kW 8.4 – 28.0 2.2 – 28.0 2.2 – 16.0 2.2 – 4.3 2.2 – 7.1 Net Weight kg 45 45 45 53 54
Capacity
Heating kW 9.6 – 31.5 2.8 – 31.5 2.8 – 18.0 2.8 – 4.9 2.5 – 8.0 Refrigerant R410A R410A R410A R410A R410A
Height mm 300 – 470 270 – 470 270 – 300 192 192
Indoor Fan
(3.0 - 6.0 HP class) or 470mm (8.0-10.0HP class) ∙ Quiet operation level (as low as 22dB(A)) Indoor Unit Power Supply AC 3 Φ, [380-415V/50Hz]
∙ Fan air flow rate up to 6 taps (DC motor model only) Net Weight kg 96 104
DUCTED
Low ESP type
∙ Low ESP (30Pa for 0.8-2.5 HP class, 60Pa for 3.0-6.0 HP Refrigerant R410A R410A
NOTE:
1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under the following
conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB)
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre
2. The sound pressure level is based on following conditions.
1.4 metre Beneath the Unit.
With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
Voltage of the power source for the indoor fan motor is 220V.
(In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is not used.
39
40
– –
MEDIUM ESP (EXTERNAL STATIC PRESSURE) TYPE LOW ESP (EXTERNAL STATIC PRESSURE) TYPE
Model RPIM-0.8HNAUNQ RPIM-1.0HNAUNQ RPIM-1.3HNAUNQ RPIM-1.5HNAUNQ RPIM-1.8HNAUNQ Model RPIL-0.8HNAUNQ RPIL-1.0HNAUNQ RPIL-1.3HNAUNQ RPIL-1.5HNAUNQ RPIL-1.8HNAUNQ RPIL-2.0HNAUNQ RPIL-2.3HNAUNQ
Indoor Unit Power Supply AC 1 Φ, [220-240V/50Hz] Indoor Unit Power Supply AC 1 Φ, [220-240V/50Hz]
Cooling kW 2.2 2.8 3.6 4.3 5.0 Cooling kW 2.2 2.8 3.6 4.3 5.0 5.6 6.3
Nominal Nominal
Capacity Capacity
Heating kW 2.8 3.3 4.2 4.9 5.6 Heating kW 2.8 3.3 4.2 4.9 5.6 6.5 7.5
Refrigerant R410A R410A R410A R410A R410A Refrigerant R410A R410A R410A R410A R410A R410A R410A
External Static Pressure *3) Pa 50(80) 50(80) 50(80) 50(80) 50(80) External Static Pressure (*3) Pa 30 30 30 30 30 30 30
Connections Flare-Nut Connection (with Flare Nuts) Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52
Piping Piping
Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25
3 3
Approximate Packing Volume m 0.22 0.22 0.22 0.22 0.28 Approximate Packing Volume m 0.22 0.22 0.22 0.22 0.28 0.28 0.28
Model RPIM-2.0HNAUNQ RPIM-2.3HNAUNQ RPIM-2.5HNAUNQ RPI-8.0FSN3Q RPI-10.0FSN3Q Model RPIL-2.5HNAUNQ RPIL-3.0HNAUNQ RPIL-3.3HNAUNQ RPIL-4.0HNAUNQ RPIL-5.0HNAUNQ RPIL-6.0HNAUNQ
Indoor Unit Power Supply AC 1 Φ, [220-240V/50Hz] AC 3 Φ, [380-415V/50Hz] Indoor Unit Power Supply AC 1 Φ, [220-240V/50Hz]
Cooling kW 5.6 6.3 7.1 22.4 28.0 Cooling kW 7.1 8.4 9.0 11.2 14.2 16.0
Nominal Nominal
Capacity Capacity
Heating kW 6.5 7.5 8.5 25.0 31.5 Heating kW 8.5 9.6 10.0 13.0 16.3 18.0
DUCTED
Refrigerant R410A R410A R410A R410A R410A Refrigerant R410A R410A R410A R410A R410A R410A
External Static Pressure *3) Pa 50(80) 50(80) 50(80) 100 100 External Static Pressure (*3) Pa 30 60 60 60 60 60
Connections Flare-Nut Connection (with Flare Nuts) Brazing Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Refrigerant Liquid Line mm Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Piping Piping
Diameter Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ19.05 Φ22.23 Diameter Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.28 0.28 0.28 0.90 1.06 Approximate Packing Volume m3 0.28 0.40 0.40 0.40 0.49 0.49
NOTE:
NOTE: 1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under the following
1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
conditions.
Cooling Operation Conditions Heating Operation Conditions
Cooling Operation Conditions Heating Operation Conditions Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) 19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB)
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) Piping Length:7.5 metre Piping Length:7.5 metre
Piping Length:7.5 metre Piping Length:7.5 metre Piping Lift:0 metre Piping Lift:0 metre
Piping Lift:0 metre Piping Lift:0 metre
2. The sound pressure level is based on following conditions.
2. The sound pressure level is based on following conditions. 1.4 metre Beneath the Unit.
1.4 metre Beneath the Unit. With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
With Discharge Duct (2.0 metre) and Return Duct (1.0 metre). Voltage of the power source for the indoor fan motor is 220V.
Voltage of the power source for the indoor fan motor is 220V. (In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
(In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).) The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is not used.
3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is not used.
41
42
– –
SLIM TYPE COMPACT TYPE
(BOTH AC MOTOR TYPE AND DC MOTOR TYPE AVAILABLE)
Model RPIZ-0.8FSNQS/P RPIZ-1.0FSNQS/P RPIZ-1.3FSNQS/P RPIZ-1.5FSNQS/P
Cooling kW 2.2 2.8 3.6 4.3 Cooling kW 2.2 2.8 3.6 4.0 5.0 5.6 6.3 7.1
Nominal
Nominal
Capacity
Capacity Heating kW 2.5 3.2 4.0 4.5 5.6 6.3 7.1 8.0
Heating kW 2.8 3.3 4.2 4.9 Sound Pressure
(Hi/Me/Lo) dB(A) 30/23/20 30/23/20 34/25/22 32.5/26/23 34/26/25 34/26/25 37/29/27 37/29/27
Level
Sound Pressure Outer
(Hi/Me/Lo) dB(A) 28/25/22 28/25/22 32/30/28 32/30/28 (H×W×D) mm 192×700×447 192×700×447 192×700×447 192×910×447 192×1,180×447 192×1,180×447 192×1,180×447 192×1,180×447
Level Dimension
Net Weight kg 17 17 17 21 27 27 28 28
Outer
(H×W×D) mm 192×700×602 192×700×602 192×700×602 192×700×602
Dimension Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A
Indoor Fan 3
Refrigerant R410A R410A R410A R410A Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
Indoor Fan Piping
(Hi/Me/Lo) m3/min 8/7/6 8/7/6 10/8/7 10/8/7
Air Flow Rate Diameter Gas Line mm Φ12.70 Φ12.70 Φ12.70 Φ12.70 Φ15.88 Φ15.88 Φ15.88 Φ15.88
External Static Standard Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Pa 10(10/30) 10(10/30) 10(10/30) 10(10/30)
Pressure (min/max)
Approximate Packing Volume m3 0.142 0.142 0.142 0.15 0.18 0.18 0.18 0.18
Connections Flare-Nut Connection (with Flare Nuts)
DUCTED
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) Indoor Fan 3 10/9/8/7.5/ 16.5/15/13/ 16.5/15/13/ 16.5/15/13/ 16.5/15/13/
(6taps) m /min 8.5/8/7/6/5.5/5 8.5/8/7/6/5.5/5 8.5/8/7/6/5.5/5
Air Flow Rate 6.5/6 12/10/9 12/10/9 12/10/9 12/10/9
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) External Static Pressure (*3) Pa 10(0-10-30) 10(0-10-30) 10(0-10-30) 10(0-10-30) 10(0-10-50) 10(0-10-50) 10(0-10-50) 10(0-10-50)
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre Connections Flare-Nut Connection (with Flare Nuts)
2. The sound pressure level is based on following conditions. Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
1.4 metre Beneath the Unit. Piping
With Discharge Duct (2.0 metre) and Return Duct (1.0 metre). Diameter Gas Line mm Φ12.70 Φ12.70 Φ12.70 Φ12.70 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Voltage of the power source for the indoor fan motor is 220V.
(In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).) Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. 3
Approximate Packing Volume m 0.142 0.142 0.142 0.15 0.18 0.18 0.18 0.18
3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is not used.
NOTE:
1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under the following
conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB)
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre
2. The sound pressure level is based on following conditions.
1.4 metre Beneath the Unit.
With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
Voltage of the power source for the indoor fan motor is 220V.
(In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is not used.
43
44
– –
FLOOR CONCEALED TYPE FLOOR / CEILING CONVERTIBLE TYPE
DIMENSIONS DIMENSIONS
RPFC-3.0FSNQ 39kg
680mm
680mm
RPFC-5.0FSNQ 47kg
230mm
620mm
• Supplies air to a wide area. • Smaller footprint: Only 230mm in depth. connects with ventilations such as a Total
• Requires little installation space thanks to its slim
• High ceiling use capability. • Suitable for installation beneath a Heat Exchanger using a duct, providing
202mm depth.
window thanks to the 680mm height. better interior air quality.
900-1,170mm
Air Inlet
DIMENSIONS DIMENSIONS
220mm
780mm
960mm 280mm
690mm RPK-0.8-1.5FSNQS 10kg
RPC-1.5 FSN3 26kg
235mm
RPC-2.0 FSN3 27kg
220mm
1,050mm
1,270mm
690mm
290mm
RPK-1.8-2.3FSNQS 12.5kg
260mm
1,100mm
1,580mm 690mm
Refrigerant
Liquid Line mm Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Model RPK-2.5FSN4M RPK-3.0FSN4M RPK-4.0FSN4M the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions
Piping Diameter Indoor Unit Power Supply AC 1Φ, [220-240V 50Hz]
Gas Line mm Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB)
Nominal Cooling kW 7.1 8.0 11.2 19.0ᵒC WB (66.2ᵒF WB)
Condensate Drain VP20 VP20 VP20 VP20 VP20 VP20 VP20 Capacity Heating kW 8.5 9.0 12.5 Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB)
Sound Pressure Piping Length:7.5 metre
Approximate Packing Volume m3 0.23 0.23 0.31 0.31 0.38 0.38 0.38 (Hi2/Hi/Me/Lo) dB(A) 45/42/38/35 47/44/40/35 51/48/44/39
Level Piping Lift:0 metre
Color White Heating Operation Conditions
NOTE:
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions. Outer Dimension (H×W×D) mm 300×1,100×260 300×1,100×260 300×1,100×260 Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
Cooling Operation Conditions Heating Operation Conditions Net Weight kg 15 15 15 Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) Refrigerant R410A R410A R410A 6ᵒC WB (43ᵒF WB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) Indoor Fan Piping Length:7.5 metre
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) (Hi2/Hi/Me/Lo) m3/min 18.5/16.5/14/12 20/17.5/15.5/12.5 23/20/17.5/14.5 Piping Lift:0 metre
Air Flow Rate
Piping Length:7.5 metre Piping Length:7.5 metre Motor W 38 38 38 2. The sound pressure level is based on following conditions.
Piping Lift:0 metre Piping Lift:0 metre Connections Flare-Nut Connection (with Flare Nuts) 1.0 metre Beneath the unit.
2. The sound pressure level is based on following conditions. Liquid Line mm Φ9.52 Φ9.52 Φ9.52 1.0 metre from Discharge grille.
Refrigerant
1.0 metre Beneath the unit. Piping Diameter Gas Line The above data was measured in an anechoic chamber so that reflected
mm Φ15.88 Φ15.88 Φ15.88
1.0 metre from Discharge grille. sound should be taken into consideration in the field. 47
Condensate Drain VP16 VP16 VP16 When bottom air inlet is adopted, sound pressure will increase according
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure. Approximate Packing Volume m3 0.14 0.14 0.14 to factors such as installation mode and the room structure. 48
–
VENTILATION
Temperature range of fresh air drawn Cooling: 20ᵒC ~ 43ᵒC, Heating: -7ᵒC ~ 15ᵒC Current (Hi/Me/Lo) A 0.6/0.5/0.4 0.8/0.7/0.6 1.0/1.0/0.7 1.6/1.5/1.1 1.72/1.58/1.31 2.04/1.93/1.73 2.35/2.09/1.92 3.03/2.45/2.18
320×250
Connection Duct Diameter mm Ø144 Ø144 Ø144 Ø194 Ø242 Ø242 Ø242
+320×250
Model RPI-16.0KFNQL RPI-16.0KFNQH RPI-20.0KFNQL RPI-20.0KFNQH RPI-20.0KFNQLF RPI-20.0KFNQHF Approximate Packing Volume m3 0.37 0.37 0.43 0.49 0.94 1.15 1.15 1.25
VENTILATION
Fan Air Flow Rate m3/h 4,000 4,000 5,000 5,000 6,000 6,000 Sound Pressure Level dB(A) 50 51 53 54 57 58
External Static Pressure Pa 200 300 200 300 200 300 Outer
(H×W×D) mm 536×1,500×1,300 536×1,500×1,400 640×1,700×1,500 640×1,750×1,600 1,655×1,400×850 1,730×1,700×850
Dimension
Refrigerant Liquid Line mm Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Net Weight kg 144 155 180 220 225 260
Piping
Diameter Gas Line mm Φ25.4 Φ25.4 Φ28.6 Φ28.6 Φ28.6 Φ28.6 Air Flow Rate m3/h 1,500 2,000 2,500 3,000 4,000 5,000
Condensate Drain RC1 (Internal Screw) External Static Pressure Pa 165 160 180 200 220 240
Temperature range of fresh air drawn Cooling: 20ᵒC ~ 43ᵒC, Heating: -7ᵒC ~ 15ᵒC Power Input W 2×440 2×810 2×925 2×1080 2×1,470 2×1,980
NOTE: Current A 2.84 3.08 4.19 5.23 5.57 7.51
1. Cooling capacity and heating capacity test in the following conditions:
Cooling conditions: 33°CDB, 28°CWB, pipeline length 7.5 metre, pipe height difference 0.0 metre 400×320 400×320 500×350 500×350 400×320 500×350
Connection Duct Diameter mm
+400×320 +400×320 +500×350 +500×350 +590×320 +700×320
Heating conditions: 0°CDB, -2.9°CWB, pipeline length 7.5 metre, pipe height difference 0.0 metre
( heating is the data without defrosting) Approximate Packing Volume m3 1.82 1.95 2.63 2.93 3.01 3.75
2. Noise test conditions are as follows:
At a distance of 1.5 metre from the unit surface. NOTE:
The above parameters are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo Please confirm the model name for "wires remote controller" compatible with Total Heat Exchanger to your local distributor.
must be counted at the scene.
3. An air filter with dust removal efficiency of 50% or more needs to be installed at the air inlet.
4. When the field duct resistance is small and the fan speed is too high, the unit will appear the phenomena of abnormal shutdown,
fault, water spray etc., and the duct pipe should be insulated to prevent generating dew.
5. Air processor can only be used for processing fresh air, indoor air conditioning load processing need to use other air conditioners.
6. Refer to capacity restrains shown on Table below for indoor unit capacity connectable to outdoor unit.
Mixed System
System Only All Fresh Air Unit System
(All Fresh Air Unit and Other Indoor Unit)
Range of i) 80 to 100%
Combination 80 to 100% and
Capacity ii) Total Capacity of All Fresh Air: 30%
7. When outdoor temperature is below 20°C in cooling operation, the system will be automatically converted to ventilation operation.
When outdoor temperature is higher than 15°C in heating operation, it will be automatically converted to ventilation operation.
When lower than -7°C, the fresh air processing unit will stop running.
49
50
– –
OPTIONAL PARTS INTRODUCTION OF MOTION SENSOR KIT
(Each number (HP class) represents the number in the model nomenclature of each indoor units)
( kW = Cooling capacity)
CEILING CASSETTE
What is it? Image
4-way cassette type 4-way cassette compact type
It senses the amount of human activity,
Decoration Panel - (included as standard equipment) Decoration Panel P-AP56NAM undertakes automatic saving and achieves
Motion Sensor
Standard operation for a room Moderate operation for a room More moderate operation if It is also possible to stop
OTHERS with a lot of human movement. with little human movement. people are absent for a certain the operation of the unit by
period. applying a particular setting if
Floor concealed type Ceiling/Floor convertible type people remain absent for more
Standard PC-RLH11 Standard PC-RLH11 than 30 minutes.
Receiver Kit Receiver Kit
Optional PC-ALHZ1 Optional PC-ALHZ1
Standard Receiver kit (PC-RLH11) is equipped with the unit in package as standard optional
part with Wireless Remote Controller (PC-LH3A).
53
54
–
LINE UP OVERVIEW
HCWA10NEGQ PC-ARH1 PC-ARF1 HCRB10NEWQ PC-LH3A PSC-A32MN PSC-A64GT PSC-A128EX PSC-A64S PSC-A16RS
RCS Groups 1 1 1 - -
LINE UP OVERVIEW
Model Display (*2) - - - -
Check Menu By indoor unit - - - -
Indoor / Outdoor PCB Check - - - -
Main 5 functions (*5) - (*6)
Alarm History Display - - -
Operation Lock / Set (*6) - - - Individual controller lock △ (*3) -
Lower Limit for Cooling Operation - - Control Function Filter sign reset -
Upper Limit for Heating Operation - -
Outdoor unit capacity control △ (*4) - - -
Built-in Timer (On / Off) -
Outdoor unit noise control - - - -
Adjusting Date / Time Setting - - -
Management Main 5 functions (*5) -
Automatic OFF timer setting - - -
Weekly Schedule - - - - Individual controller lock -
Settable Timer Operation Times (Per Day) - - 5 - - Alarm status & code - (*7)
Schedule
Holiday Setting - - - - Monitor Function
Filter sign -
Schedule On / Off - - - -
Power Saving with Motion Sensor - - - - Air inlet temperature of indoor unit - -
Outdoor Unit Peak cut control - - - - Air inlet temperature of outdoor unit - -
capacity control moderate control - - - -
Power Weekly - (*8) - (*8)
Saving Indoor Unit Address - - - -
Indoor Unit
Rotation Control Indoor Air Temperature difference Schedule Setting times per day 10 10 16 3 (*8) 3 (*8)
- - - -
Function Special day setting - - 5 - -
Automatic Fan Operation - - - -
ODU silent mode - - - - Annual/Summer/Winter schedule - - - -
Quick Function - - - - Alarm history (records number) 100 100 10000 - -
Comfort setting Control Cool Air - - - -
MENU External in/output history - - 1000 - -
Saving/ODU Noise Reduction Schedule - - - - Other function
Daylight Saving Time - - - - Management report visualization - -
Power Consumption visualization - - - - Data output by external media - - SD card, USB flash device - -
(*1) One external adapter can control [128 remote controller groups / 128 groups / 32 blocks],
(*1) All 16 indoor units need to be connected with transition wire. and Central Station EX can connect up to 15 adapters.
(*2) Availability depends on the indoor unit type connected to the each individual controllers. Please consult (*2) No restriction on the number of H-LINK
your distributors for more details. (*3) Individual Function Control in Each Remote Controller is not applicable
(*3) 6 taps is available for Ducted indoor unit, compact type, RPIZ-HNDTSQ only. (*4) Applicable by Schedule function or External Signal input
(*4) Indicated temperature can be selected from two options, the thermistor in the indoor unit or in the (*5) Main 5 functions mean 1) Run/Stop 2) Operation mode 3) Temperature setting 4) Fan speed 5) Louver control
individual controller. (*6) Only Run/Stop is available 55
(*5) Please contact your distributor in case temperature unit needs to be changed from °C to °F. (*7) Alarm Code cannot be displayed, but Operation indicator keeps flashing in red to inform abnormal condition
(*6) Only "bulk operation lock" available (*8) Available with 7-day timer (PSC-A1T) 56
–
WIRED REMOTE CONTROLLER HCWA10NEGQ
Temperature display
Room temperature
SPECIFICATIONS
Outer Dimensions (H×W×D)
Set temperature
(mm) 88.0×88.0×15.5
Liquid Crystal Display
(LCD) Screen FUNCTIONS
ON/OFF Button Run / Stop
Mode Button Up Button & Down Button Operation Mode
Auto Mode
Operation Mode Temperature Setting Rate _ 0.5°C/1°C/1°F
Setting
Temperature Unit _ °C/ °F
Cooling Mode Fan Speed _ 3/4/6 taps
MIN
INDIVIDUAL CONTROLLERS
–
SIMPLIFIED WIRED REMOTE CONTROLLER PC-ARH1
SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 120.0×70.0×17.0
FUNCTIONS
TEMP (Temperature Setting) Run / Stop
Run Indicator (Red)
Switch Operation Mode
ON / OFF Switch
Auto Mode Setting
Temperature Setting
Operation Mode Switch Swing Louver Setting
(Swing Louver Operation) Temperature setting rate_°C (0.5/1)_°F(1)
: FAN
: COOL Switch Back-light screen
: HEAT
: DRY Fan Speed_ 3/4/6 taps
: AUTO Louver Direction
By repeatedly pressing
Fan Speed Switch *Please contact your dealer in case “temperature setting rate”
the button, the setting
By repeatedly pressing the button, needs to be changed from °C to °F.
will change sequentially.
the fan speed setting will change sequentially.
57
58
–
ADVANCED WIRED REMOTE CONTROLLER PC-ARF1
INDIVIDUAL CONTROLLERS
2 IDU Connection Up to 16 IDU Connection
Improved main-sub RCS control Thermometer function
By one main RCS, you can Current temperature can be
control the multiple IDUs displayed anytime, without
which are controlled by being in maintenance mode.
........
2 RCS sub RCS. *Thermometer can be chosen out of 3
control is ........ sensors (Air inlet, Air outlet, Remote
available * Operation Mode controller)
* Setting Temperature
Up to 16 IDU Main RCS Sub RCS Sub RCS Sub RCS
H-LINK
Primary RCS Secondary RCS Transition wiring is necessary Remote Control Cable Alarm code check Help Menu
Contact address shown in Access when in trouble.
the same display. Screen guide, Operation
Manuals, Troubleshooting
Q&A listed.
Run/Stop Filter Sign With Motion Sensor Kit
Operation Mode Filter Sign Reset
ODU Capacity Control
Auto Mode Setting Louver Open / Close • Peak Shaving Control
Service
Room Name Setting • Proper Limit Control
Temperature Setting
Fan Speed _ 3/4/6 taps Alarm Sign Power-Saving Indoor Unit Rotation Control ODU silent mode
Louver Direction Alarm History Display Automatic Fan Operation
Setting Screen Adjustment Set in the weekly schedule by
Individual Louver Setting Auto Recovery of Temperature
Screen Temperature Unit - °C /°F 5 times.
Remote Control Primary-Secondary Setting Upper Limit for Heating Operation
Automatic Restart with Adjusting Brightness of Run Indicator
Lower Limit for Cooling Operation
Eco-operation Operation Lock / Set
Function Weekly Schedule
Automatic Reset Temperature Main / Sub Control
Selection (Cooling/Heating) Settable Timer Operation Times (per day): 5
Management Built-in-Timer (on/off)
Temperature Indication Schedule Holiday Setting
Adjusting Date / Time Setting
Schedule On / Off 59
Thermometer Indication
ODU Noise Reduction Schedule
60
– –
ADVANCED WIRELESS REMOTE CONTROLLER HCRB10NEWQ RECEIVER KIT FOR WIRELESS REMOTE CONTROLLER
(*1) Fan speed = 3 taps available only when you use the standard receiver kit (PC-RLH11 or HR4A10NEWQ)
(*2) Concerning only [Floor/Ceiling Convertible type: RPFC-FSNQ] & [Wall Mounted Unit: RPK-FSNQS]Standard Receiver kit (PC-RLH11) is
equipped with the unit in package as standard optional part with Wireless Remote Controller (PC-LH3A)
(*3) Receiver Kit is installed in the unit as standard part. Please use Receiver Kit (PC-ALHZ1) when receiver kit needs to be installed
separately from unit.
H-LINK Notes
Remote Control Cable When you use standard receiver kit (PC-RLH11 or HR4A10NEWQ) equipped with wireless remote controller (PC-LH3A)
1) Setting Hi2 air flow rate is not available even if the connected indoor units has Hi2 air flow rate setting
2)It is not available to set up "remote control switch operation prohibited by each function setting" from central station (mini/EZ/EX)
3) It is not available to set up "remote control switch temperature setting range limitation function" from central station (mini/EZ/EX)
INDIVIDUAL CONTROLLERS
–
WIRELESS REMOTE CONTROLLER PC-LH3A
Transmitter
SPECIFICATIONS
Outer Dimensions (H×W×D)
Transmitting Indication (mm) 125.0×56.0×16.4
61
62
–
FOR SMALL-SCALE BUILDINGS
CENTRAL STATION mini PSC-A32MN
22 52.7
CAPACITY (5-inch) Touch Panel Operation Schedule
RC group 32 Easy to check the operation status using either of two monitoring Up to 10 actions/day per RCS
For example :
Group 32 screens (all groups or four pattern blocks [2/4/8/16]) group can be set as available as auto School
Block 4 Patterns (2/4/8/16) switch‑off timer
Indoor Unit 160
Outdoor Unit 64
Building Scale Small In case of classroom
120mm mini
in cooling mode
SPECIFICATIONS
9:00 ~ 10:00 27 °C Class: on
10:00 ~ 11:00 27 °C Class: on
Rated Power Supply 1-, AC 100-240V, 50/60Hz 11:00 ~ 12:00 - °C No class: off
Electrical Power Consumption 20W (Max.) 12:00 ~ 13:00 25 °C LUNCH TIME
FUNCTIONS
[Monitor (Block)]
• Run/Stop/Abnormality • Setting Temperature
• RCS Operation Prohibited Setting
Monitor Function • Accumulated Operating Time
Most compact in our touch panel centralized • Operation Mode • Setting Fan Speed
• Setting Louver • Filter Sign • Alarm Code"
controller. Its down-to-detail control • Run/Stop* • Fan Speed
functionalities, such as Weekly Scheduling, Control Function
• Operation Mode • Louver
• Temperature Setting RCS Group Function Control Accumulated Operation-Time Visualization
Accumulated Work Hours, etc., help you save • RCS Operation Prohibited
‑each operational item blocking‑prevent incorrect operation Support energy-saving management
• Filter Sign Reset
energy. Up to 32 remote-controlled groups and
*:“All Groups Run/Stop” command signal exception function for selected groups is
up to 160 indoor units can be connected to the available by “Exception of Run/Stop Operation.” function.
single air-conditioning system.
CENTRALIZED CONTROLLERS
RECOMMENDED FACILITIES
Total 32
RCS Groups
H-LINK
Remote Control Cable
64
–
FOR MEDIUM-SCALE BUILDINGS
CENTRAL STATION EZ PSC-A64GT
25
80
55 CAPACITY (8.5-inch) Touch Panel Operation
RC group 64 A total of 64 remote controller groups (4 blocks)(64 outdoor units/160 indoor units) can be controlled
Group 64 Easy to check the operation status using either of two monitoring screens (all groups or blocks)
Block 4 Patterns
The panel for the block is bigger than for the CS MINI; you can check Mode, Fan Speed, Louver, Temperature, Inlet and Ambient Temperature.
Indoor Unit 160
Outdoor Unit 64
170mm Building Scale Small - Medium
SPECIFICATIONS
Rated Power Supply 1-, AC 100-240V, 50/60Hz
Electrical Power Consumption 30W (Max.)
FUNCTIONS
[Monitor 1 (all groups)] [Monitor 2 (block)]
Monitor Function
• RCS Operation Prohibited Setting
• Accumulated Operating Time ACCUMULATED OPERATION-TIME VISUALIZATION
Easy control with 8.5 inch color touch panel, • Operation Mode • Setting Fan Speed
• Setting Louver • Filter Sign • Alarm Code Supports Energy-Saving Management
Its down-to-detail control functionalities, • Run/Stop* • Fan Speed
such as Weekly Scheduling, Accumulated Work Hours, Control Function
• Operation Mode • Louver
• Temperature Setting
etc., help you save energy. Up to 64 remote-controlled • RCS Operation Prohibited
• Filter Sign Reset
groups and up to 160 indoor units can be connected *:“All Groups Run/Stop” command signal exception function for selected groups
to the single air-conditioning system. is available by “Exception of Run/Stop Operation.” function.
CENTRALIZED CONTROLLERS
RECOMMENDED FACILITIES
Alarm Information
Red color indication: immediate display of malfunction location and cause.
HOSPITAL OFFICE SMALL NURSING HOME HOTEL SCHOOL
BUILDING
CS EZ
Schedule
Up to 10 actions/day per RCS groups can be set as available as auto switch‑off timer.
Total 64
RCS Groups
H-LINK
Remote Control Cable
65
For large scale buildings such as hotels, educational BETTER ENERGY SAVING AND QUICKER MANAGEMENT
facilities, or hospitals, our Central Station EX features
Management reports can be visualized in various ways, and data
a highly intuitive and functional 12.1-inch wide, wall-
mountable, colorful LCD screen. Control up to 2,560 can be acquired using SD memory and USB flash devices.
indoor units with our proprietary H-LINK system with
15 Extension Adapters (PSC-AD128EX) The following data can be displayed up
Various data such as operation time, to the previous two years:
settings, and log history can be
CENTRALIZED CONTROLLERS
saved to CSV files for better energy • Accumulated operation time (min.)
management and quicker service • Accumulated thermo-ON time (min.)
maintenance. • Average air intake temperature of
RECOMMENDED FACILITIES SD indoor unit
• Average air intake temperature of
outdoor unit
USB
• Average setting temperature
• Average RC sensor temperature
OFFICE HOSPITAL HOTEL SCHOOL
(It may not be available depending
on RC settings.)
FUNCTIONS
All together Each of the following setting is available in 3 Energy saving
Each area different [annual] [summer][winter] category • Run/Stop
Operation Drag to change the schedule
Each block => Weekly schedule • RC prohibition
unit
Each group => Up to 16 actions can be set per day • Temperature shift IMPROVED SCHEDULE SETTING Flick and swipe to see a different screen
Each RCS group => Exception day setting: 5 different types (For Cool/Dry mode: +1°C ~ +9°C (+1°F ~ +18°F))
=> Holiday setting (For Heat mode: -1°C ~ -9°C (-1°F ~ -18°F))
On/Off
• Mode shift
Three long-term category settings are now available: Annual,
Mode
Set temperature Schedule Setting items in schedule is as below; (Mode shifted to Fan when in Cool/Dry mode, Summer, and Winter.
Fan speed function • On/off and shifted to Stop in Heat mode)
Louver • Operation mode • Capacity control on outdoor units
Control • Setting temperature • Lower noise control for outdoor units
RC prohibition
function • Louver External input Touch and hold the memory axis to
Filter sign reset
Function selection for indoor units (*1) • Fan speed / output Control/Monitor add the memory to the schedule
Function selection for outdoor units (*2) • RC operation prohibition => Controlled items:
Capacity control for outdoor units (*2) • Capacity control for outdoor units • Run/Stop
Lower noise control for outdoor units (*2) • Lower noise control for outdoor units • Mode (Cool/Heat) Schedules can be color coded for
Alarm history: 10,000 records => Monitored items:
On/Off
• Run/Stop
easy confirmation
Mode History External In/Output history: 1,000 records
Pulse input history: 6 months • Mode (Cool/Heat)
Set temperature
• Alarm state
Air intake temperature Each of the following data of up to 2 years
RC sensor temperature (*3) can be shown: Touch the + button to see the
Others detailed schedule
Monitor Air intake temperature of outdoor unit • Accumulated operation time (min.)
function • Power consumption signal input
Fan Speed • Accumulated thermo-ON time (min.)
Management • Emergency stop
Louver • Average air intake temp temperature of
report
RC prohibition indoor unit (*1) Some indoor units may not fully support all functions.
visualization
Thermo-ON information • Average air intake temperature of outdoor (*2) It is available for applicable outdoor units only.
Filter sign/Auto cleaning fault unit (*3) There is a case that it cannot be shown in the screen, 67
Alarm status/Alarm codes • Average setting temperature
depending on the remote controller setting.
• Average RC sensor temperature 68
–
FOR LARGE-SCALE BUILDINGS
CENTRAL STATION EX PSC-A128EX
2. Layout style
Upload your own layout images in multiple formats (BMP, JPEG,
PNG) and easily arrange indoor units by dragging them on the
CENTRALIZED CONTROLLERS
touch panel.
Normal mode Temperature mode Power consumption mode
Floor view
69
SPECIFICATIONS SPECIFICATIONS
Outer Dimensions (H×W×D) Outer Dimensions (H×W×D)
(mm) 120.0×120.0×70.5 (mm) 120.0×120.0×68.5
CAPACITY CAPACITY
120mm RC group 64 120mm RCS group 16
Group 64 Group 64
Block 4 Patterns Block -
Indoor Unit 160 Indoor Unit 160
Outdoor Unit 64 Outdoor Unit -
CENTRALIZED CONTROLLERS
*Be sure to use it with a remote control switch. Indoor
units cannot be used without a remote control
switch.
71
72
–
H-LINK
PO I N T
Flexible Wiring Routes
WHAT IS H-LINK? H-LINK is a "Hitachi" original communication system that can be used to control multiple outdoor (1) If indoor units are located
and indoor units from one control point. Its use assists installers and service engineers by simplifying in one place and the indoor
commissioning and service maintenance. For building owners and occupants, it provides outstanding unit to be controlled is in the
Point!
versatility enabling the connection of various types of central control options, enabling better system room where “Centralized
Controller” is installed
management. Our proprietary high-performance communication system enables the connection
verall control is possible by
O
of control wiring between indoor and outdoor units, and between a centralized control system and connecting “Centralized Controller” to
indoor/outdoor units across two or more refrigerant systems. the indoor unit.
Delivery distance can be greatly
ADVANTAGES 1. A multi air conditioner for a building and a package air conditioner for a store or office. It can be used
PSC-A32MN
with a home air conditioner.
H-LINK
completely separated
verall control is possible by separately
O Point!
Point!
RECOMMENDED connecting the two systems to
“Centralized Controller.”
FACILITY (EXAMPLE) It is possible to select a wiring route based
on the wiring distance and the ease of
Educational institutions such otels where it is preferable
H Rehabilitation facilities or installation.
as primary schools where to complete installation work hospitals where it is necessary
installation work cannot be during late evenings. to minimize the burden on
performed on weekdays. users.
PSC-A32MN
SPECIFICATIONS SPECIFICATIONS
Outer Dimensions (H×W×D) Outer Dimensions (H×W×D)
(mm) 68.0×240.0×154.0 (mm) 120.0×120.0×17.0
FUNCTIONS
Corresponding ANSI / ASHRAE Standard 135-2004
BACnet® Standard BACnet®
• Run Stop (Setting)
• Operation Mode (Setting)
EXAMPLE OF SYSTEM H-LINK
Remote Control Cable
Control Item at
Upper System
• Fan Speed Level (Setting)
• Indoor Temperature (Setting)
CONFIGURATION BACnet ® • Prohibiting RC Operation (Setting)
• Filter Sign Reset
• Run Stop (State)
OTHERS
Bigger Connection Capacity (Up to 128 Indoor Units)
SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 80.0×170.0×75.0
FUNCTIONS
Connection Connection by SNVT
LONWORKS®
75
HARC-70PE1 76
–
OUR HERITAGE
MAIN PRODUCTS
Air Compressor, Roller, PAC, Refrigerators, Compressor PAC, Refrigerators, VRF, PAC,
Casting Casting for REF, Casting Compressor Compressors
Indoor unit:
Indoor unit: Ceiling
Compressor for Floor-exposed
Cassette type
Refrigerators type (RPF)
OUR HERITAGE
1943
1951
1952
1956
1958
1961
1963
1965
1970
1971
1972
1973
1976
1978
1979
1981
1982
1983
1984
1986
1988
1990
1991
1996
1999
2003
2005
2011
2012
2016
Roller for mill
Indoor unit: Centrifugal VRF
1st air-cooled Unitary Point:“Outdoor unit”
Shimizu Factory Wall Mounted VRF 2ND GENERATION
PAC for export market Outdoor unit: that can be installed
Founded type (RPK) –
for low-ambient- 5HP 8HP & 10HP inside the building
Hitachi’s 1st Inverter-
temperature driven VRF With Scroll VRF 4TH GENERATION
market Compressor built-in 10 HP
Large casting; Hitachi’s 1st Packaged –
fan for tunnel AC (Water-cooled) Up to 8 indoor units (130% capacity)
(Floor Standing type) World 1st IGBT built-in Inverter
VRF leading to top-in-class
quietest operation
2nd Overseas Factory
founded in Brazil VRF 8TH GENERATION
Scroll Compressor
96HP
Production for
–
AC unit
Hitachi New Generation VRF
This New Generation VRF
is 8th Generation VRF
VRF 6TH GENERATION after 33 Years Experience in VRF
1st Overseas Factory 3rd overseas factory 32 HP
founded in Taiwan in Malaysia –
Newly R410A adopted VRF 77
“SET FREE FSN”: heat-pump type
“SET FREE FXN”: heat-recovery type 78