HNBQ Catalogue PDF (Low-Res) - Compressed

Download as pdf or txt
Download as pdf or txt
You are on page 1of 40

SET FREE Σ
VARIABLE REFRIGERANT FLOW
AIR SOURCE HEAT PUMP TYPE
HNBQ SERIES


Company Name
– –
CUSTOMER SERVICE CERTIFICATION


SALES OFFICE


SPARE PARTS –
WARRANTY


DISTRIBUTOR


SOCIAL MEDIA

1810-C-HNBQ-1
– –

Welcome The beauty of balance


No matter what the weather is like outside,
when you're indoors, you want to have complete
control over your environment. At work or play,
awake or asleep, you're free to create your own
atmosphere; balancing energy with calm, sound
with silence and light with shade. It's the same for
cooling and heating.

When the air around you is in balance,


– you can enjoy life indoors that much more.

Air. It’s a

SET FREE Σ HNBQ series



wonderful thing.
Living Harmony
Invisible, silent and life-giving, air makes
our entire world possible. It surrounds us, At Hitachi Cooling & Heating we like to think of
continuously energizing, cooling and warming. It this as creating harmony with your interior
can be unpredictable and sometimes challenging, environment. When we achieve that wonderful
but when air is in harmony with us, everything balance, productivity, learning, happiness
seems that much easier. and health can thrive.

This is our vision. We call this ‘Living Harmony’ and it’s at the
To create the air that makes life better. center of everything we do.


The future together
Living Harmony puts people first. By balancing
the human needs of our customers with an
uncompromising approach to innovation
and quality, we can continue to create the

WELCOME
technologies for a more comfortable and
balanced world.

Your world. We live in it together.

01

02
– –

Your world
Design for tomorrow’s
urban spaces.

and Hitachi
Space in our cities is under increasing
pressure and as new buildings become
more space efficient, the areas allocated
to cooling and heating are shrinking.
We are responding to these changes with
a new generation of space-efficient
outdoor units, giving architects,
building managers and owners greater
levels of flexibility.

SET FREE Σ HNBQ series


Learn more about Outdoor Unit
on page 07

– –
Change in the air. Redefining comfort.
Change is one of the few constants in life.
Comfort can be felt in a variety of ways, from the
The world around us changes continuously and as it does, so do our own
temperature to quietness and even the air flow
comfort levels and our requirements of our buildings.
itself. Our wide-ranging lineup of indoor units can
meet various comfort requirements. We offer two
Creating harmony in the face of change has always been the driving force
different types of ventilation units, and optional
behind Hitachi Cooling & Heating. From maintaining a perfect indoor climate
motion sensors are also available for superior
indoors as the seasons change, to developing new technology to address the
energy saving.
needs of our changing cities, we’re committed to solutions that help people

YOUR WORLD AND Hitachi


adapt to changes today and in the future.

Learn more about Indoor Unit
on page 29


You are in control.
Whether you wish to create a relaxing
atmosphere in your home, improve
productivity at work or manage the
energy and maintenance costs for your
building, We give you the technology
to achieve your goals. From setting
individual climate zones in every room,
to centralized monitoring and reporting
for multiple buildings.


Learn more about Controller
on page 53 03

04

INDEX

07 OUTDOOR UNITS

SET FREE Σ HNBQ series


09 LINE UP OVERVIEW
11 HIGH EFFICIENCY
13 DESIGN FLEXIBILITY
15 ADAPTABILITY
17 SPECIFICATIONS
28 OPTIONAL PARTS

29 INDOOR UNITS & VENTILATION


31 LINE UP OVERVIEW
35 CEILING CASSETTE

INDEX
39 DUCTED FSNQ series
45 EXPOSED & CONCEALED
49 VENTILATION
51 OPTIONAL PARTS
52 INTRODUCTION OF MOTION SENSOR KIT

53 CONTROLLERS
55 LINE UP OVERVIEW
57 INDIVIDUAL CONTROLLERS
63 CENTRALIZED CONTROLLERS
73 H-LINK
75 OTHERS
77 OUR HERITAGE 05

06

Raising
the standard

SET FREE Σ HNBQ series


RAISING THE STANDARD
The path to creating your perfect indoor
environment begins outdoors with
Hitachi Cooling & Heating’s range of
outdoor units —
the first step toward achieving Living
Harmony.
Protected by lighter and stronger
compact cabinets and powered by the
world’s most advanced compressor
controller technology, the next
generation SET FREE Σ outdoor units
deliver superior performance, maximum
installation flexibility and ease of
maintenance.

07

08

LINE UP OVERVIEW

Widest Range: from 8 to 88HP class

The HNBQ Series is newly launched with a wide range of models in its lineup,
as well as a variety of performance enhancements in design,
power and economy. Select the product(s) most suitable for your application,
either as a single unit or a combination of single units.
(HP Class / Cooling Capacity / Heating Capacity / Net Weight)
Single module

SET FREE Σ HNBQ series


up to 22HP class!

1,725mm
1,725mm

1,725mm
1,725mm

1,725mm

1,725mm
4,824mm 782mm 5,262mm 782mm 5,652mm 782mm
958mm 782mm 1,218mm 782mm 1,608mm 782mm

8HP Class / 22.4kW / 25.0kW / 248kg 12HP Class / 33.5kW / 37.5kW / 308kg 18HP Class / 50.0kW / 56.0kW / 390kg 54HP Class / 150.0kW / 168.0kW / 1,170kg 62HP Class / 175.0kW / 196.0kW / 1,458kg 64HP Class / 180.0kW / 202.0kW / 1,492kg
10HP Class / 28.0kW / 31.5kW / 248kg 14HP Class / 40.0kW / 45.0kW / 356kg 20HP Class / 56.0kW / 63.0kW / 415kg 56HP Class / 156.0kW / 175.0kW / 1,195kg 66HP Class / 185.0kW / 207.0kW / 1,492kg
16HP Class / 45.0kW / 50.0kW / 356kg 22HP Class / 61.5kW / 69.0kW / 416kg 58HP Class / 162.0kW / 182.0kW / 1,220kg
60HP Class / 168.0kW / 189.0kW / 1,245kg Whole range
up to 88HP class!

1,725mm
1,725mm
1,725mm
1,725mm
1,725mm

LINE UP OVERVIEW
6,042mm 782mm 6,432mm 782mm
2,436mm 782mm 2,826mm 782mm 3,216mm 782mm

24HP Class / 67.0kW / 75.0kW / 616kg 34HP Class / 95.0kW / 106.0kW / 746kg 36HP Class / 100.0kW / 112.0kW / 780kg 68HP Class / 190.0kW / 213.0kW / 1,526kg 72HP Class / 200.0kW / 224.0kW / 1,560kg 82HP Class / 229.5kW / 258.0kW / 1,661kg
26HP Class / 73.5kW / 82.5kW / 664kg 38HP Class / 106.0kW / 119.0kW / 805kg 70HP Class / 195.0kW / 218.0kW / 1,526kg 74HP Class / 206.0kW / 231.0kW / 1,585kg 84HP Class / 235.0kW / 264.0kW / 1,662kg
28HP Class / 80.0kW / 90.0kW / 712kg 40HP Class / 112.0kW / 126.0kW / 830kg 76HP Class / 212.0kW / 238.0kW / 1,610kg 86HP Class / 240.5kW / 270.0kW / 1,663kg
30HP Class / 85.0kW / 95.0kW / 712kg 78HP Class / 218.0kW / 245.0kW / 1,635kg 88HP Class / 246.0kW / 276.0kW / 1,664kg
32HP Class / 90.0kW / 100.0kW / 712kg 80HP Class / 224.0kW / 252.0kW / 1,660kg
SUMMARY TABLE
Item Unit HNBQ Series
HP class 8- 88
Capacity Nominal Cooling kW 22.4 - 246.0
Nominal Heating kW 25.0 - 276.0
Maximum connectable indoor unit quantity 14 - 64
1,725mm

Combination capacity ratio between ODU and IDU % 50 - 140


1,725mm

1,725mm

Total piping length m 1,000


Actual m 165
Refrigerant piping length
Equivalent m 190
Maximum piping length
Between piping connection kit and each outdoor unit m 10
Between 1st branch multi kit and farthest indoor unit m 90(*1)
3,654mm 782mm 4,044mm 782mm 4,434mm 782mm Between multi kit and each indoor unit m 40
Between outdoor units (combination of base units) m 0.1
42HP Class / 120.0kW / 135.0kW / 1,068kg 50HP Class / 140.0kW / 156.0kW / 1,102kg 52HP Class / 145.0kW / 162.0kW / 1,136kg ODU above IDU m 50 (standard) / up to 110m (custom order)(*2)
Maximum level difference ** Between outdoor unit and indoor units
44HP Class / 125.0kW / 140.0kW / 1,068kg IDU above ODU m 40
46HP Class / 130.5kW / 145.0kW / 1,068kg Between indoor units m 30
48HP Class / 135.0kW / 150.0kW / 1,068kg Cooling operation range * °C DB -5 to 52
Heating operation range * °C WB -20 to 15
* For more details, please consult your distributors or dealer, or, refer to technical catalogue.
** Concerning maximum level difference between ODU and IDU (ODU above IDU),
Standard: up to 50 metre/Custom Order: up to 110 metre. 09
Longer piping (up to 110 metre) is available for 8 to 48HP class models only.
Maximum level difference for 50-88HP class is 90 metre. 10

HIGH EFFICIENCY

EFFICIENCY RATIO 3 POINTS IMPROVEMENT


1) COMPRESSOR
EER: Energy Efficiency Ratio
Greater capacity control
5.0
4.62 The highly improved performance as well 100%
100% 15Hz ~ 100Hz 100%
100% 11Hz ~125Hz
4.09
4.0
4.10 4.02 3.91 3.77 3.62 3.68 as greater energy saving is achieved by 85 Steps 1140 Steps
adopting newly developed high efficiency (by 1Hz) (by 0.1Hz)

Inverter Compressor
Inverter Compressor

Control Capacity
Control Capacity
3.0
DC inverter compressor, with outstandingly
2.0 precise control technology of 0.1Hz

SET FREE Σ HNBQ series


1.0 increments inverter frequency. Another
feature is the dramatically extended Inverter
Inverter Inverter
Inverter
0.0 Compressor
Compressor Compressor
Compressor
8 10 12 14 16 18 20 22 HP Class working range, enabled by expanding the
20%
20% 10%
10%
compressor’s operating frequency band,
Max.
Max. Cooling
CoolingLoad
Load Min.
Min.
Max.
Max. Min.
Min.
both upwards and downwards. Cooling
CoolingLoad
Load

COP: Coefficient Of Performance Current model* New model*


*Example at 12HP class[33.5kW]

5.0
4.90 4.70 4.90 4.76
4.35 4.41
4.06 3.88
4.0
3.0
2.0
2) HEAT EXCHANGER
1.0
0.0
• The heat exchange area has been increased by more than 10% (single module)
8 10 12 14 16 18 20 22 HP Class • Greater heat exchange efficiency
Split left-right
New shape heat exchanger
Improved angle
Notes: of the curve
1. The cooling and heating capacities above show the maximum capacities when the outdoor
Σ shape !

HIGH EFFICIENCY
and indoor temperature are under the following conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB)
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre

2. Please see the technical catalogues for more details.

WHAT'S IMPROVED? 1) COMPRESSOR 2) HEAT EXCHANGER 3) AIR OUTLET Current model (single module) New single medium & Large cabinet Current model (single module) New single medium & Large cabinet

3) AIR OUTLET
• Improvement of airflow volume by 23
% (single module)
• Energy consumption in the driving shaft has decreased by 20% on average
Expansion of air outlet Improvement in air outlet
Air outlets area Smoother air flow

+ 40 %
Narrower

Longer
New (Twin-fan)

121
0m
m Less short
Air volume area………6334cm2
circuit !! 11
Current model New model Current model New model 12

DESIGN FLEXIBILITY

EASY TRANSPORTATION IMPROVED EXTERNAL STATIC PRESSURE


• Smaller cabinet Both more numbers of setting of ESP (up to 4), and, higher ESP (up to 80Pa) of outdoor unit,
offer better options for the indoor installation of the outdoor unit, which leads to 3 benefits for you.
• Less piping length
• Lower installation cost
• Visual aesthetics

Can be transported

SET FREE Σ HNBQ series


in an elevator 800mm Current Model New Model
by pallet jack 0Pa 60Pa 0Pa 30Pa 60Pa 80Pa
HNBQ:12HP class(33.5kW) Wall
Wall CeilingCeiling
Wall
Wall Air Outlet Duct Kit (*)
Air Outlet Duct Kit (*)
(Field Supply)
(Field Supply)
Duct
Duct Duct (Field Supplied)
Duct (Field Supplied) (Field Supplied)
(Field Supplied)
The recommended air
The recommended air
outlet duct kit (*) has
outlet duct kit (*) has
flanged opening, which makes
flanged opening, which makes
the field connection work possible
the field connection work possible
765mm
2,160mm 1,608mm 782mm
*Example at 22HP class [61.5kW]
1,218mm
Installation Space -24.4% (1.65m2 1.26m2)
22HP class
(61.5kw) 782mm
Product Weight -17.8% (530kg 416kg)
1,350mm Wall Outdoor Unit Wall Outdoor Unit
Wall Outdoor Unit Wall Outdoor Unit

DESIGN FLEXIBILITY
PIPING CONNECTION WORKABILITY Piping connection kit 1st Branch Multi kit OPERATION TEMPERATURE RANGE
• Suitable for a high- rise building or complex facilities. Enhanced performance in consideration of the actual installation environment of the outdoor unit
• Leads to cost/time saving for designers, with more efficient design.
Gas pipe Liquid pipe Gas pipe Liquid pipe

Cooling Operation
Maximum piping length
Unit
Total piping length m 1,000
52
Actual m 165
Refrigerant piping length Interval Operation Working Range

Outdoor Air Temperature °C DB


Equivalent m 190
Between "Piping connection kit" and each ODU m 10
48
Up to 110m(*1)

Between "1st branch Multi Kit" and farthest IDU m 90(*1)


Between "Multi Kit" and each IDU m 40

Maximum level difference


Continuous Operation
Unit
Working Range
Between ODU (combination of base units) m 0.1
50 (standard) /
ODU above IDU m
Between ODU and IDU up to 110 (custom order)(*2)
30m

IDU above ODU m 40


Between indoor units m 30 -5
Each maximum length or level difference has several conditions,please refer to the technical documents in inquiry.
(*1) 30 metre at maximum,in case the number of connected indoor unit is over the recommendation.
(*2) Standard:up to 50 metre/Custom Order:up to 110 metre.
When the maximum level difference is greater than 50 metre, please contact your local dealer or distributor.
Maximum level difference (up to 110 metre) is available for 8 to 48 HP class models only.
Maximum level difference for 50 to 88HP class is 90 metre.
15 23
Indoor Air Inlet Temperature (°C WB)
Multi kit 90m
165m
(Actual)
13
Gas pipe Liquid pipe
14

ADAPTABILITY

IMPROVED COMPRESSOR CONTROL TO PREVENT FAILURE


Smooth drive Standardize the running time of the individual outdoor units

The model calculates the appropriate amount of refrigerant supplied by the outdoor units on the basis and distribute the load by rotating the order of operation of the compressors of the outdoor units.
of information about the required load from the individual indoor units. The model employs smooth
operation control to control the number of revolutions of the inverter compressor. The model supplies
the appropriate amount of refrigerant to the indoor units according to the required load. The model
increases energy-saving efficiency by operating smoothly while controlling the switching on and off of

SET FREE Σ HNBQ series


the compressor at low-load operation.
off on on

concept of smooth drive control


Charge proper
Calculate proper amount of refrigerant
amount of refrigerant to
charge according Refrigerant flow
to the load information. Piping

Rotation

Inverter on on off on off on
compressor Indoor Unit Indoor Unit

Transmit Transmit
load load
Outdoor Unit information information

ADAPTABILITY
Transmission Wire (Conceptual Drawing)

Actual example of the new compressor control


Hitachi Original! BACK UP FUNCTION
Current model New model Full introduction of backup operation function. If one outdoor
unit should fail, the model can continue to operate using the
Room 30 Room 30
Temp Temp remaining outdoor units, thereby preventing total system failure.
(°C) (°C)
25 25
Unstable Temperature
20 Combined Outdoor Unit
20
Constant Room
15 15 Temperature
10 10
Energy Consumption Loss
Power 5 5 Smoother operation
consumption Power
(kW) consumption
0 (kW) 0
60 Time(min) 120 180 60 120 180
Time(min)

Room Temperature(°C)
Room Temperature(°C)
Power consumption(kW)
Power consumption(kW)
due to
frequent switching -39%
energy consumed
on/off operation
15

16

SPECIFICATIONS

HP class 8HP class 10HP class 12HP class 14HP class 16HP class 18HP class 20HP class 22HP class 24HP class

Combination of single module unit 12+12

Model RAS-8.0HNBBMQ RAS-10HNBBMQ RAS-12HNBBMQ RAS-14HNBBMQ RAS-16HNBBMQ RAS-18HNBBMQ RAS-20HNBBMQ RAS-22HNBBMQ RAS-24HNBBMQ

Power Supply V/Ph/Hz 380/400/415V±10% 3n~50Hz 380/400/415V±10% 3n~50Hz 380/400/415V±10% 3n~50Hz

SET FREE Σ HNBQ series


Cooling kW 22.4 28.0 33.5 40.0 45.0 50.0 56.0 61.5 67.0
Capacity
Heating kW 25.0 31.5 37.5 45.0 50.0 56.0 63.0 69.0 75.0
Cooling kW 4.85 6.83 8.19 9.95 11.50 13.25 15.45 16.70 16.38
Power Input
Heating kW 5.10 6.70 7.65 9.45 11.50 12.70 15.50 17.80 15.30
Air Flow Rate Standard m3/min 171 171 239 256 256 329 329 348 239+239
Dimension H×W×D mm 1,725×958×782 1,725×958×782 1,725×1,218×782 1,725×1,218×782 1,725×1,218×782 1,725×1,608×782 1,725×1,608×782 1,725×1,608×782 1,725×2,436×782
Weight Net kg 248 248 308 356 356 390 415 416 616
Footprint Area m2 0.75 0.75 0.95 0.95 0.95 1.26 1.26 1.26 0.95+0.95
Packaging Volume m3 1.62 1.62 2.03 2.03 2.03 2.67 2.67 2.67 2.03+2.03
Compressor type Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll)
Type R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant
Charge Amount kg 7.2 7.2 8.9 10.7 10.7 11.3 11.3 12.6 17.8
Model FV68H FV68H FV68H FV68H FV68H FV68H FV68H FV68H FV68H
Refrigerant Oil
Charge Amount L 6.0 6.0 6.9 7.9 7.9 8.4 8.4 8.4 13.8
Number of Fan Motors 1 1 2 2 2 2 2 2 4
Capacity Ratio of IDU/ODU 50-140% 50-140% 50-140% 50-140% 50-140% 50-140% 50-140% 50-140% 50-140%
Anechoic dB(A) 57 58 59 60 61 61 62 63 63
Noise
Semi-anechoic dB(A) 60 61 62 63 64 64 65 66 66
Liquid mm φ12.7(1/2) φ12.7(1/2) φ12.7(1/2) φ15.88(5/8) φ15.88(5/8) φ15.88(5/8) φ15.88(5/8) φ15.88(5/8) φ19.05(3/4)
Piping

SPECIFICATIONS
Gas mm φ25.4(1) φ25.4(1) φ25.4(1) φ28.58(1-1/8) φ28.58(1-1/8) φ28.58(1-1/8) φ28.58(1-1/8) φ28.58(1-1/8) φ31.75(1-1/4)
Max A 27.0 27.0 31.5 43.5 43.5 45.0 52.0 61.5 31.5+31.5
Breaker A 32 32 40 63 63 63 63 80 40+40
Current
Cooling A 8.4 11.9 14.6 17.0 19.9 23.4 27.1 33.2 14.6+14.6
Heating A 8.9 11.7 13.5 15.8 19.4 23.0 27.2 33.0 13.5+13.5
EER W/W 4.62 4.10 4.09 4.02 3.91 3.77 3.62 3.68 4.09
Efficiency
COP W/W 4.90 4.70 4.90 4.76 4.35 4.41 4.06 3.88 4.90
The max IDU connect qty. 14 17 21 24 28 31 35 38 42
Cooling Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB
Working temp. range
Heating Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB
Refrigerant control mode electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve
Tubing connection method Welding connection Welding connection Welding connection
Total piping length m 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
Actual m 165 165 165 165 165 165 165 165 165
Refrigerant piping length
Maximum Equivalent m 190 190 190 190 190 190 190 190 190
piping
length Between "Piping connection kit" and each outdoor unit m 10 10 10 10 10 10 10 10 10
Between "1st branch Multi Kit" and farthest indoor unit m 90(*1) 90 90 90 90 90 90 90 90
Between "Multi Kit" and each indoor unit m 40 40 40 40 40 40 40 40 40
Between outdoor units (combination of base units) m 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
50 (standard) / up to 1150 (standard) / 50 (standard) / up to 1150 (standard) / 50 (standard) / up to 1150 (standard) /
Maximum ODU above IDU(*) m
Between outdoor unit and indoor up to 110m (custom order)(*2)0m (custom order)(*2) up to 110m (custom order)(*2)0m (custom order)(*2) up to 110m (custom order)(*2)0m (custom order)(*2)
level
units
difference
IDU above ODU m 40 40 40 40 40 40 40 40 40

Between indoor units m 30 30 30 30 30 30 30 30 30

Notes:
1. The cooling and heating performances are the values when combined with our test indoor units. 2. The sound pressure is based on the following conditions. (*) Standard: up to 50 metre/Custom Order: up to 110 metre.
Cooling Operation Conditions Heating Operation Conditions 1 metre from the unit service cover surface, and 1.36 metre from floor level. Longer piping (up to 110 metre) is available for 8 to 48HP class models only.
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) The above data is based on the cooling mode. In case of heating mode, the sound pressure Maximum level difference for 50 to 88HP class is 90 metre.
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) level increases by approximately 1~2 dB(A). The above data was measured in a semi-anechoic
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) chamber so that reflected sound should be taken into consideration in the field. 17
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre 18

SPECIFICATIONS

HP class 26HP class 28HP class 30HP class 32HP class 34HP class 36HP class 38HP class 40HP class 42HP class

Combination of single module unit 12+14 14+14 14+16 16+16 16+18 18+18 18+20 20+20 14+14+14

Model RAS-26HNBBMQ RAS-28HNBBMQ RAS-30HNBBMQ RAS-32HNBBMQ RAS-34HNBBMQ RAS-36HNBBMQ RAS-38HNBBMQ RAS-40HNBBMQ RAS-42HNBBMQ

Power Supply V/Ph/Hz 380/400/415V±10% 3n~50Hz 380/400/415V±10% 3n~50Hz 380/400/415V±10% 3n~50Hz

SET FREE Σ HNBQ series


Cooling kW 73.5 80.0 85.0 90.0 95.0 100.0 106.0 112.0 120.0
Capacity
Heating kW 82.5 90.0 95.0 100.0 106.0 112.0 119.0 126.0 135.0
Cooling kW 18.14 19.90 21.45 23.00 24.75 26.50 28.70 30.90 29.85
Power Input
Heating kW 17.10 18.90 20.95 23.00 24.20 25.40 28.20 31.00 28.35
Air Flow Rate Standard m3/min 239+256 256+256 256+256 256+256 256+329 329+329 329+329 329+329 256+256+256
Dimension H×W×D mm 1,725×2,436×782 1,725×2,436×782 1,725×2,436×782 1,725×2,436×782 1,725×2,826×782 1,725×3,216×782 1,725×3,216×782 1,725×3,216×782 1,725×3,654×782
Weight Net kg 664 712 712 712 746 780 805 830 1,068
Footprint Area m2 0.95+0.95 0.95+0.95 0.95+0.95 0.95+0.95 0.95+1.26 1.26+1.26 1.26+1.26 1.26+1.26 0.95+0.95+0.95
Packaging Volume m3 2.03+2.03 2.03+2.03 2.03+2.03 2.03+2.03 2.03+2.67 2.67+2.67 2.67+2.67 2.67+2.67 2.03+2.03+2.03
Compressor type Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll)
Type R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant
Charge Amount kg 19.6 21.4 21.4 21.4 22.0 22.6 22.6 22.6 23.7
Model FV68H FV68H FV68H FV68H FV68H FV68H FV68H FV68H FV68H
Refrigerant Oil
Charge Amount L 14.8 15.8 15.8 15.8 16.3 16.8 16.8 16.8 23.7
Number of Fan Motors 4 4 4 4 4 4 4 4 6
Capacity Ratio of IDU/ODU 50-140% 50-140% 50-140% 50-140% 50-140% 50-140% 50-140% 50-140% 50-140%
Anechoic dB(A) 63 63 64 64 64 65 65 65 65
Noise
Semi-anechoic dB(A) 66 66 67 67 67 68 68 68 68
Liquid mm φ19.05(3/4) φ19.05(3/4) φ19.05(3/4) φ19.05(3/4) φ19.05(3/4) φ19.05(3/4) φ19.05(3/4) φ19.05(3/4) φ19.05(3/4)
Piping

SPECIFICATIONS
Gas mm φ31.75(1-1/4) φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2)
Max A 31.5+43.5 43.5+43.5 43.5+43.5 43.5+43.5 43.5+45.0 45.0+45.0 45.0+52.0 52.0+52.0 43.5+43.5+43.5
Breaker A 40+63 63+63 63+63 63+63 63+63 63+63 63+63 63+63 63+63+63
Current
Cooling A 14.6+17.0 17.0+17.0 17.0+19.9 19.9+19.9 19.9+23.4 23.4+23.4 23.4+27.1 27.1+27.1 17.0+17.0+17.0
Heating A 13.5+15.8 15.8+15.8 15.8+19.4 19.4+19.4 19.4+23.0 23.0+23.0 23.0+27.2 27.2+27.2 15.8+15.8+15.8
EER W/W 4.05 4.02 3.96 3.91 3.84 3.77 3.69 3.62 4.02
Efficiency
COP W/W 4.82 4.76 4.53 4.35 4.38 4.41 4.22 4.06 4.76
The max IDU connect qty. 45 49 52 56 59 63 64 64 64
Cooling Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB
Working temp. range
Heating Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB
Refrigerant control mode electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve
Tubing connection method Welding connection Welding connection Welding connection
Total piping length m 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
Actual m 165 165 165 165 165 165 165 165 165
Refrigerant piping length
Maximum Equivalent m 190 190 190 190 190 190 190 190 190
piping
length Between "Piping connection kit" and each outdoor unit m 10 10 10 10 10 10 10 10 10
Between "1st branch Multi Kit" and farthest indoor unit m 90 90 90 90 90 90 90 90 90
Between "Multi Kit" and each indoor unit m 40 40 40 40 40 40 40 40 40
Between outdoor units (combination of base units) m 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
50 (standard) 50 (standard) 50 (standard)
Maximum ODU above IDU(*) m
Between outdoor unit and indoor up to 110 (custom order) up to 110 (custom order) up to 110 (custom order)
level
units
difference
IDU above ODU m 40 40 40 40 40 40 40 40 40

Between indoor units m 30 30 30 30 30 30 30 30 30

Notes:
1. The cooling and heating performances are the values when combined with our test indoor units. 2. The sound pressure is based on the following conditions. (*) Standard: up to 50 metre/Custom Order: up to 110 metre.
Cooling Operation Conditions Heating Operation Conditions 1 metre from the unit service cover surface, and 1.36 metre from floor level. Longer piping (up to 110 metre) is available for 8 to 48HP class models only.
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) The above data is based on the cooling mode. In case of heating mode, the sound pressure Maximum level difference for 50 to 88HP class is 90 metre.
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) level increases by approximately 1~2 dB(A). The above data was measured in a semi-anechoic
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) chamber so that reflected sound should be taken into consideration in the field. 19
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre 20

SPECIFICATIONS

HP class 44HP class 46HP class 48HP class 50HP class 52HP class 54HP class 56HP class 58HP class 60HP class

Combination of single module unit 14+14+16 14+16+16 16+16+16 16+16+18 16+18+18 18+18+18 18+18+20 18+20+20 20+20+20

Model RAS-44HNBBMQ RAS-46HNBBMQ RAS-48HNBBMQ RAS-50HNBBMQ RAS-52HNBBMQ RAS-54HNBBMQ RAS-56HNBBMQ RAS-58HNBBMQ RAS-60HNBBMQ

Power Supply V/Ph/Hz 380/400/415V±10% 3n~50Hz 380/400/415V±10% 3n~50Hz 380/400/415V±10% 3n~50Hz

SET FREE Σ HNBQ series


Cooling kW 125.0 130.0 135.0 140.0 145.0 150.0 156.0 162.0 168.0
Capacity
Heating kW 140.0 145.0 150.0 156.0 162.0 168.0 175.0 182.00 189.0
Cooling kW 31.40 32.95 34.50 36.25 38.00 39.75 41.95 44.15 46.35
Power Input
Heating kW 30.40 32.45 34.50 35.70 36.90 38.10 40.90 43.70 46.50
Air Flow Rate Standard m3/min 256+256+256 256+256+256 256+256+256 256+256+329 256+329+329 329+329+329 329+329+329 329+329+329 329+329+329
Dimension H×W×D mm 1,725×3,654×782 1,725×3,654×782 1,725×3,654×782 1,725×4,044×782 1,725×4,434×782 1,725×4,824×782 1,725×4,824×782 1,725×4,824×782 1,725×4,824×782
Weight Net kg 1,068 1,068 1,068 1,102 1,136 1,170 1,195 1,220 1,245
Footprint Area m2 0.95+0.95+0.95 0.95+0.95+0.95 0.95+0.95+0.95 0.95+0.95+1.26 0.95+1.26+1.26 1.26+1.26+1.26 1.26+1.26+1.26 1.26+1.26+1.26 1.26+1.26+1.26
Packaging Volume m3 2.03+2.03+2.03 2.03+2.03+2.03 2.03+2.03+2.03 2.03+2.03+2.67 2.03+2.67+2.67 2.67+2.67+2.67 2.67+2.67+2.67 2.67+2.67+2.67 2.67+2.67+2.67
Compressor type Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll)
Type R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant
Charge Amount kg 23.7 23.7 23.7 24.2 24.7 25.2 25.2 25.2 33.9
Model FV68H FV68H FV68H FV68H FV68H FV68H FV68H FV68H FV68H
Refrigerant Oil
Charge Amount L 23.7 23.7 23.7 24.2 24.7 25.2 25.2 25.2 25.2
Number of Fan Motors 6 6 6 6 6 6 6 6 6
Capacity Ratio of IDU/ODU 50-140% 50-140% 50-140% 50-140% 50-140% 50-140% 50-140% 50-140% 50-140%
Anechoic dB(A) 66 66 66 66 66 67 67 67 67
Noise
Semi-anechoic dB(A) 69 69 69 69 69 70 70 70 70
Liquid mm φ19.05(3/4) φ19.05(3/4) φ19.05(3/4) φ19.05(3/4) φ19.05(3/4) φ19.05(3/4) φ19.05(3/4) φ19.05(3/4) φ19.05(3/4)
Piping

SPECIFICATIONS
Gas mm φ38.1(1-1/2) φ38.1(1-1/2) φ38.1(1-1/2) φ44.5(1-3/4) φ44.5(1-3/4) φ44.5(1-3/4) φ44.5(1-3/4) φ44.5(1-3/4) φ44.5(1-3/4)
Max A 43.5+43.5+43.5 43.5+43.5+43.5 43.5+43.5+43.5 43.5+43.5+45.0 43.5+45.0+45.0 45.0+45.0+45.0 45.0+45.0+52.0 45.0+52.0+52.0 52.0+52.0+52.0
Breaker A 63+63+63 63+63+63 63+63+63 63+63+63 63+63+63 63+63+63 63+63+63 63+63+63 63+63+63
Current
Cooling A 17.0+17.0+19.9 17.0+19.9+19.9 19.9+19.9+19.9 19.9+19.9+23.4 19.9+23.4+23.4 23.4+23.4+23.4 23.4+23.4+27.1 23.4+27.1+27.1 27.1+27 .1+27.1
Heating A 15.8+15.8+19.4 15.8+19.4+19.4 19.4+19.4+19.4 19.4+19.4+23.0 19.4+23.0+23.0 23.0+23.0+23.0 23.0+23.0+27.2 23.0+27.2+27.2 27.2+27.2+27.2
EER W/W 3.98 3.95 3.91 3.86 3.82 3.77 3.72 3.67 3.62
Efficiency
COP W/W 4.61 4.47 4.35 4.37 4.39 4.41 4.28 4.16 4.06
The max IDU connect qty. 64 64 64 64 64 64 64 64 64
Cooling Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB
Working temp. range
Heating Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB
Refrigerant control mode electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve
Tubing connection method Welding connection Welding connection Welding connection
Total piping length m 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
Actual m 165 165 165 165 165 165 165 165 165
Refrigerant piping length
Maximum Equivalent m 190 190 190 190 190 190 190 190 190
piping
length Between "Piping connection kit" and each outdoor unit m 10 10 10 10 10 10 10 10 10
Between "1st branch Multi Kit" and farthest indoor unit m 90 90 90 90 90 90 90 90 90
Between "Multi Kit" and each indoor unit m 40 40 40 40 40 40 40 40 40
Between outdoor units (combination of base units) m 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
50 (standard) 50 (standard) 50 (standard)
Maximum ODU above IDU(*) m
Between outdoor unit and indoor up to 110 (custom order) up to 90 (custom order) up to 90 (custom order)
level
units
difference
IDU above ODU m 40 40 40 40 40 40 40 40 40

Between indoor units m 30 30 30 30 30 30 30 30 30

Notes:
1. The cooling and heating performances are the values when combined with our test indoor units. 2. The sound pressure is based on the following conditions. (*) Standard: up to 50 metre/Custom Order: up to 110 metre.
Cooling Operation Conditions Heating Operation Conditions 1 metre from the unit service cover surface, and 1.36 metre from floor level. Longer piping (up to 110 metre) is available for 8 to 48HP class models only.
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) The above data is based on the cooling mode. In case of heating mode, the sound pressure Maximum level difference for 50 to 88HP class is 90 metre.
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) level increases by approximately 1~2 dB(A). The above data was measured in a semi-anechoic
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) chamber so that reflected sound should be taken into consideration in the field. 21
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre 22

SPECIFICATIONS

HP class 62HP class 64HP class 66HP class 68HP class 70HP class 72HP class 74HP class 76HP class 78HP class

Combination of single module unit 14+14+16+18 14+14+18+18 14+16+18+18 14+18+18+18 16+18+18+18 18+18+18+18 18+18+18+20 18+18+20+20 18+20+20+20

Model RAS-62HNBBMQ RAS-64HNBBMQ RAS-66HNBBMQ RAS-68HNBBMQ RAS-70HNBBMQ RAS-72HNBBMQ RAS-74HNBBMQ RAS-76HNBBMQ RAS-78HNBBMQ

Power Supply V/Ph/Hz 380/400/415V±10% 3n~50Hz 380/400/415V±10% 3n~50Hz 380/400/415V±10% 3n~50Hz

SET FREE Σ HNBQ series


Cooling kW 175.0 180.0 185.0 190.0 195.0 200.0 206.0 212.0 218.0
Capacity
Heating kW 196.0 202.0 207.0 213.0 218.0 224.0 231.0 238.0 245.0
Cooling kW 44.65 46.40 47.95 49.70 51.25 53.00 55.20 57.40 59.60
Power Input
Heating kW 43.10 44.30 46.35 47.55 49.60 50.80 53.60 56.40 59.20
Air Flow Rate Standard m3/min 256+256+256+329 256+256+329+329 256+256+329+329 256+329+329+329 256+329+329+329 329+329+329+329 329+329+329+329 329+329+329+329 329+329+329+329
Dimension H×W×D mm 1,725×5,262×782 1,725×5,652×782 1,725×5,652×782 1,725×6,042×782 1,725×6,042×782 1,725×6,432×782 1,725×6,432×782 1,725×6,432×782 1,725×6,432×782
Weight Net kg 1,458 1,492 1,492 1,526 1,526 1,560 1,585 1,610 1,635
Footprint Area m2 0.95+0.95+0.95+1.26 0.95+0.95+1.26+1.26 0.95+0.95+1.26+1.26 0.95+1.26+1.26+1.26 0.95+1.26+1.26+1.26 1.26+1.26+1.26+1.26 1.26+1.26+1.26+1.26 1.26+1.26+1.26+1.26 1.26+1.26+1.26+1.26
Packaging Volume m3 2.03+2.03+2.03+2.67 2.03+2.03+2.67+2.67 2.03+2.03+2.67+2.67 2.03+2.67+2.67+2.67 2.03+2.67+2.67+2.67 2.67+2.67+2.67+2.67 2.67+2.67+2.67+2.67 2.67+2.67+2.67+2.67 2.67+2.67+2.67+2.67
Compressor type Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll)
Type R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant
Charge Amount kg 43.4 44.0 44.0 44.6 44.6 45.2 45.2 45.2 45.2
Model FV68H FV68H FV68H FV68H FV68H FV68H FV68H FV68H FV68H
Refrigerant Oil
Charge Amount L 32.1 32.6 32.6 33.1 33.1 33.6 33.6 33.6 33.6
Number of Fan Motors 8 8 8 8 8 8 8 8 8
Capacity Ratio of IDU/ODU 50-140% 50-140% 50-140% 50-140% 50-140% 50-140% 50-140% 50-140% 50-140%
Anechoic dB(A) 67 67 67 67 68 68 68 68 68
Noise
Semi-anechoic dB(A) 70 70 70 70 71 71 71 71 71
Liquid mm φ22.2(7/8) φ22.2(7/8) φ22.2(7/8) φ22.2(7/8) φ22.2(7/8) φ22.2(7/8) φ22.2(7/8) φ22.2(7/8) φ22.2(7/8)
Piping

SPECIFICATIONS
Gas mm φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2)
Max A 43.5+43.5+43.5+45.0 43.5+43.5+45.0+45.0 43.5+43.5+45.0+45.0 43.5+45.0+45.0+45.0 43.5+45.0+45.0+45.0 45.0+45.0+45.0+45.0 45.0+45.0+45.0+52.0 45.0+45.0+52.0+52.0 45.0+52.0+52.0+52.0
Breaker A 63+63+63+63 63+63+63+63 63+63+63+63 63+63+63+63 63+63+63+63 63+63+63+63 63+63+63+63 63+63+63+63 63+63+63+63
Current
Cooling A 17.0+17.0+19.9+23.4 17.0+17.0+23.4+23.4 17.0+19.9+23.4+23.4 17.0+23.4+23.4+23.4 19.9+23.4+23.4+23.4 23.4+23.4+23.4+23.4 23.4+23.4+23.4+27.1 23.4+23.4+27.1+27.1 23.4+27.1+27.1+27.1
Heating A 15.8+15.8+19.4+23.0 15.8+15.8+23.0+23.0 15.8+19.4+23.0+23.0 15.8+23.0+23.0+23.0 19.4+23.0+23.0+23.0 23.0+23.0+23.0+23.0 23.0+23.0+23.0+27.2 23.0+23.0+27.2+27.2 23.0+27.2+27.2+27.2
EER W/W 3.92 3.88 3.86 3.82 3.80 3.77 3.73 3.69 3.66
Efficiency
COP W/W 4.55 4.56 4.47 4.48 4.40 4.41 4.31 4.22 4.14
The max IDU connect qty. 64 64 64 64 64 64 64 64 64
Cooling Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB
Working temp. range
Heating Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB
Refrigerant control mode electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve
Tubing connection method Welding connection Welding connection Welding connection
Total piping length m 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
Actual m 165 165 165 165 165 165 165 165 165
Refrigerant piping length
Maximum Equivalent m 190 190 190 190 190 190 190 190 190
piping
length Between "Piping connection kit" and each outdoor unit m 10 10 10 10 10 10 10 10 10
Between "1st branch Multi Kit" and farthest indoor unit m 90 90 90 90 90 90 90 90 90
Between "Multi Kit" and each indoor unit m 40 40 40 40 40 40 40 40 40
Between outdoor units (combination of base units) m 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
50 (standard) 50 (standard) 50 (standard)
Maximum ODU above IDU(*) m
Between outdoor unit and indoor up to 90 (custom order) up to 90 (custom order) up to 90 (custom order)
level
units
difference
IDU above ODU m 40 40 40 40 40 40 40 40 40

Between indoor units m 30 30 30 30 30 30 30 30 30

Notes:
1. The cooling and heating performances are the values when combined with our test indoor units. 2. The sound pressure is based on the following conditions. (*) Standard: up to 50 metre/Custom Order: up to 110 metre.
Cooling Operation Conditions Heating Operation Conditions 1 metre from the unit service cover surface, and 1.36 metre from floor level. Longer piping (up to 110 metre) is available for 8 to 48HP class models only.
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) The above data is based on the cooling mode. In case of heating mode, the sound pressure Maximum level difference for 50 to 88HP class is 90 metre.
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) level increases by approximately 1~2 dB(A). The above data was measured in a semi-anechoic
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) chamber so that reflected sound should be taken into consideration in the field. 23
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre 24

SPECIFICATIONS

HP class 80HP class 82HP class 84HP class 86HP class 88HP class

Combination of single module unit 20+20+20+20 20+20+20+22 20+20+22+22 20+22+22+22 22+22+22+22

Model RAS-80HNBBMQ RAS-82HNBBMQ RAS-84HNBBMQ RAS-86HNBBMQ RAS-88HNBBMQ

Power Supply V/Ph/Hz 380/400/415V±10% 3n~50Hz 380/400/415V±10% 3n~50Hz

SET FREE Σ HNBQ series


Cooling kW 224.0 229.5 235.0 240.5 246.0
Capacity
Heating kW 252.0 258.0 264.0 270.0 276.0
Cooling kW 61.80 63.05 64.30 65.55 66.80
Power Input
Heating kW 62.00 64.30 66.60 68.90 71.20
Air Flow Rate Standard m3/min 329+329+329+329 329+329+329+348 329+329+348+348 329+348+348+348 348+348+348+348
Dimension H×W×D mm 1,725×6,432×782 1,725×6,432×782 1,725×6,432×782 1,725×6,432×782 1,725×6,432×782
Weight Net kg 1,660 1,661 1,662 1,663 1,664
Footprint Area m2 1.26+1.26+1.26+1.26 1.26+1.26+1.26+1.26 1.26+1.26+1.26+1.26 1.26+1.26+1.26+1.26 1.26+1.26+1.26+1.26
Packaging Volume m3 2.67+2.67+2.67+2.67 2.67+2.67+2.67+2.67 2.67+2.67+2.67+2.67 2.67+2.67+2.67+2.67 2.67+2.67+2.67+2.67
Compressor type Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll) Hermetic(Scroll)
Type R410A R410A R410A R410A R410A
Refrigerant
Charge Amount kg 45.2 46.5 47.8 49.1 50.4
Model FV68H FV68H FV68H FV68H FV68H
Refrigerant Oil
Charge Amount L 33.6 33.6 33.6 33.6 33.6
Number of Fan Motors 8 8 8 8 8
Capacity Ratio of IDU/ODU 50-140% 50-140% 50-140% 50-140% 50-140%
Anechoic dB(A) 68 68 68 69 69
Noise
Semi-anechoic dB(A) 71 71 71 72 72
Liquid mm φ22.2(7/8) φ25.4(1) φ25.4(1) φ25.4(1) φ25.4(1)
Piping

SPECIFICATIONS
Gas mm φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2) φ50.8(2)
Max A 52.0+52.0+52.0+52.0 52.0+52.0+52.0+61.5 52.0+52.0+61.5+61.5 52.0+61.5+61.5+61.5 61.5+61.5+61.5+61.5
Breaker A 63+63+63+63 63+63+63+80 63+63+80+80 63+80+80+80 80+80+80+80
Current
Cooling A 27.1+27.1+27.1+27.1 27.1+27.1+27.1+33.2 27.1+27.1+33.2+33.2 27.1+33.2+33.2+33.2 33.2+33.2+33.2+33.2
Heating A 27.2+27.2+27.2+27.2 27.2+27.2+27.2+33.0 27.2+27.2+33.0+33.0 27.2+33.0+33.0+33.0 33.0+33.0+33.0+33.0
EER W/W 3.62 3.64 3.65 3.67 3.68
Efficiency
COP W/W 4.06 4.01 3.96 3.92 3.88
The max IDU connect qty. 64 64 64 64 64
Cooling Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB Stable work at-5~52°C DB(*1) and interval at 48°C~52°C DB
Working temp. range
Heating Stable work at -20°C~15°C WB Stable work at -20°C~15°C WB
Refrigerant control mode electronic expansion valve microcomputer-controlled electronic expansion valve microcomputer-controlled electronic expansion valve
Tubing connection method Welding connection Welding connection
Total piping length m 1,000 1,000 1,000 1,000 1,000
Actual m 165 165 165 165 165
Refrigerant piping length
Maximum Equivalent m 190 190 190 190 190
piping
length Between "Piping connection kit" and each outdoor unit m 10 10 10 10 10
Between "1st branch Multi Kit" and farthest indoor unit m 90 90 90 90 90
Between "Multi Kit" and each indoor unit m 40 40 40 40 40
Between outdoor units (combination of base units) m 0.1 0.1 0.1 0.1 0.1
50 (standard) 50 (standard)
Maximum ODU above IDU(*) m
Between outdoor unit and indoor up to 90 (custom order) up to 90 (custom order)
level
units
difference
IDU above ODU m 40 40 40 40 40

Between indoor units m 30 30 30 30 30

Notes:
1. The cooling and heating performances are the values when combined with our test indoor units. 2. The sound pressure is based on the following conditions. (*) Standard: up to 50 metre/Custom Order: up to 110 metre.
Cooling Operation Conditions Heating Operation Conditions 1 metre from the unit service cover surface, and 1.36 metre from floor level. Longer piping (up to 110 metre) is available for 8 to 48HP class models only.
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) The above data is based on the cooling mode. In case of heating mode, the sound pressure Maximum level difference for 50 to 88HP class is 90 metre.
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) level increases by approximately 1~2 dB(A). The above data was measured in a semi-anechoic
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) chamber so that reflected sound should be taken into consideration in the field. 25
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre 26

OPTIONAL PARTS

PIPING CONNECTION KIT


Number of modules of Example: M-30SNQ
Model Outdoor unit capacity
1 outdoor unit
OD31.75 ID22.2
M-30SNQ 24-26HP class 2 OD31.75 ID22.2
Gas side Liquid side Reducer
M-46SNQ 28-40HP class 2 ID9.53
ID38.1 ID22.2 ID9.53
ID15.88 ID28.6 ID25.4
M-46SNQ+M-30SNQ 42-48HP class 3 ID38.1 ID22.2 OD31.75
ID28.6 ID22.2
ID25.4
ID31.75 ID32.0 ID19.05 ID15.88
ID19.05
ID31.75 ID32.0 ID19.05 ID19.05 ID25.4 ID15.88
M-68SNQ+M-30SNQ 50-60HP class 3 ID38.1 Ø31.75 ID25.4
OD28.6 ID15.88ID12.7

SET FREE Σ HNBQ series


ID38.1 Ø31.75 ID9.53
M-68SNQ+M-30SNQ+M-30SNQ 62-88HP class 4 ID38.1 ID22.2Ø25.4 ID15.88 OD28.6
ID28.6 ID12.7
ID25.4
ID12.7
ID31.75 Ø31.75 ID32.0 Ø25.4
ID19.05 ID19.05
Ø19.05 ID12.7
ID22.2
Ø19.05 ID22.2 ID25.4 ID22.2 ID15.88 ID19.05
Ø31.75 Ø31.75
ID38.1 ID15.88 Ø22.2 OD28.6 ID22.2 ID19.05
ID12.7
Ø28.6 ID15.88 Ø22.2
Ø28.6 ID12.7 OD38.1
ID28.6 Ø25.4
ID12.7 ID12.7
ID28.6 ID9.53 ID6.35 OD38.1
Ø31.75 Ø19.05
ID9.53 ID22.2
ID6.35 ID22.2 ID19.05
ID15.88 Ø22.2
Ø28.6 ID34.92
ID12.7 ID34.92
OD38.1
ID28.6 ID9.53 ID6.35

ID34.92

MULTI-KIT
1) 1st branch Multi-kit
Main Piping ≥ 100m Main Piping < 100m Example: E-462SN
Model Outdoor unit capacity Model Outdoor unit capacity
Gas side Liquid side Reducer
E-242SN 8-12HP class E-162SN 8-12HP class
ID44.5 ID9.53
ID9.53 ID9.53 Ø44.5 Ø44.5Ø44.5 ID28.6
ID28.6 ID28.6
E-302SN 14-22HP class E-242SN 14-22HP class ID41.3
ID41.3 ID41.3 ID44.5 ID44.5 ID22.2
ID22.2
ID22.2ID12.7
ID12.7
ID12.7
ID44.5
ID44.5 ID44.5 ID41.3
ID41.3 ID41.3 ID19.05 ID25.4
ID25.4 ID25.4
E-462SN 24-48HP class E-302SN 24-48HP class ID19.05 ID19.05ID15.88
ID15.88 ID15.88
ID38.1
ID38.1 ID31.75
ID38.1 ID31.75 ID31.75
E-682SN 50-88HP class E-462SN 50-60HP class ID19.05
ID19.05 ID19.05
Ø41.3Ø41.3
Ø41.3 Ø41.3Ø41.3Ø25.4
Ø41.3 Ø25.4Ø25.4 ID22.2 Ø28.6Ø28.6 ID15.88
ID15.88 ID15.88
ID22.2 Ø28.6
ID22.2 ID12.7 ID25.4
ID25.4 ID
E-682SN 62-88HP class Ø19.05
Ø19.05 Ø19.05 Ø25.4 Ø25.4Ø25.4 ID12.7 ID12.7
Ø38.1Ø38.1 ID31.75
Ø38.1 ID31.75
ID31.75 ID15.88 ID9.53
ID15.88ID15.88 ID9.53 ID9.53
ID38.1
ID38.1 ID38.1 ID12.7 ID6.35

OPTIONS
ID28.6 ID12.7 ID12.7 ID6.35 ID6.35ID22.2
ID22.2 ID19.05
ID22.2 ID19.05 ID19.05
ID28.6 ID28.6
ID44.5 ID9.53 Ø44.5 ID28.6
ID41.3 ID22.2 ID12.7
2) Multi-kit after 1st branch and pipe diameter ID44.5 ID41.3 ID19.05 ID15.88 ID25.4
Diameter (mm) ID38.1 ID31.75
Q= ID19.05
Model Ø41.3 Ø41.3 Ø25.4 ID22.2 Ø28.6 ID15.88
Total indoor unit capacity (kW) Gas Pipe Liquid Pipe ID25.4
Ø19.05 Ø25.4 ID12.7
Ø38.1 ID31.75 ID15.88 ID9.53
Q ≤ 15.9 15.88 9.52 ID38.1
ID12.7 ID6.35 ID22.2 ID19.05
ID28.6
E-102SN 16 ≤ Q < 25 19.05 9.52
25 ≤ Q < 33.5 22.2 9.52
33.5 ≤ Q < 45 25.4 12.7
E-162SN
45 ≤ Q < 50 28.58 12.7
E-242SN 50 ≤ Q < 72.9 28.58 15.88
72.9 ≤ Q < 100.8 31.75 19.05
E-302SN
100.8 ≤ Q < 156.8 38.1 19.05
156.8 ≤ Q < 190.4 44.45 19.05
E-462SN
190.4 ≤ Q < 207.2 44.45 22.2
207.2 ≤ Q < 252 50.8 22.2
E-682SN 252 ≤ Q < 274.4 50.8 25.4
274.4 ≤ Q < 349.5 50.8 28.58

27

28

Indoor life

SET FREE Σ HNBQ series


INDOOR LIFE
At work or at home, you want to be in
control of your indoor environment.
Of course that environment can take
many forms, so the new SET FREE Σ range
offers you the widest choice of indoor
units, with the versatility to complement
any interior.
Named after the distinctive shape of its
patented heat exchanger, SET FREE Σ is a
next generation VRF system,
setting new standards in power, reliability
and efficiency.
From small spaces to the largest
buildings, you can create your own living
harmony.

29

30

LINE UP OVERVIEW

COMPARING INDOOR UNITS CAPACITY KEY INFORMATION

kW (Cooling) CEILING CASSETTE


IDU Category
1.6 2.2 2.8 3.6 4.0 4.3 5.0 5.6 6.3 7.1 7.4 8.0 8.4 9.0 11.0 14.0 14.2 16.0 22.4 28.0
4-WAY
CASSETTE TYPE

4-WAY CASSETTE
CEILING CASSETTE

4-WAY CASSETTE TYPE 4-WAY CASSETTE COMPACT TYPE 2-WAY CASSETTE TYPE 1-WAY CASSETTE TYPE
COMPACT TYPE ∙ With area of air distribution with ∙ Dimensions correspond with ∙ Motion sensor available for better ∙ Motion sensor available for better

SET FREE Σ HNBQ series


4 direction of louvers (distribution 600mm × 600mm architectural energy saving operation energy saving operation
with distance available with module ceiling design ∙ Ideal for a higher ceiling location ∙ Optimum air flow conditions
optional parts (duct flange) specifications for installation (up to 4.6m in are created by either downward
2-WAY CASSETTE TYPE ∙ Motion sensor available for better ∙ Quiet operation level (as low as cooling mode) air discharge or frontal air
energy saving operation 24.5 dB(A)) ∙ Individual louvres operation for discharge (via optional grille) or a
∙ Individual four-way louvres for ∙ Wide range of air flow rate ideal greater comfort for individual combination of both
greater comfort for individual for high ceiling installation with users ∙ Quiet operation level (as low as
users 4.6m air blow down in cooling ∙ Quiet operation level (as low as 27dB(A))
1-WAY CASSETTE TYPE ∙ Ideal for a higher ceiling location mode 27dB(A))
for installation (up to 5.5m in
cooling mode)

HIGH ESP TYPE

DUCTED
MEDIUM ESP TYPE

LOW ESP TYPE


DUCTED

HIGH ESP TYPE MEDIUM ESP TYPE LOW ESP TYPE SLIM TYPE COMPACT TYPE
∙ High ESP (90/120Pa for 3.0-6.0 HP ∙ 2 steps of medium ESP (50/80Pa ∙ Low ESP (30Pa for 0.8-2.5 HP ∙ Ideal for narrow ceiling voids (BOTH AC MOTOR TYPE AND
class, 180Pa for 8.0-10.0 HP class) for 0.8- 2.5 HP class, 100Pa for class, 60Pa for 3.0-6.0 HP class) installation thanks to low height DC MOTOR TYPE AVAILABLE)
SLIM TYPE ∙ Space saving design thanks to a 8.0-10.0 HP class) ∙ Space saving design thanks to a up to 192mm & width just 700mm
∙ Ideal for installation over the
height of only 300mm (3.0 - 6.0 ∙ Space saving design thanks to a height of only 270mm (0.8-2.5HP ∙ Drain-pump with 900mm lift as
closet or windows thanks to
HP class) or 470mm (8.0-10.0HP height of only 270mm (0.8 - 2.5HP class) or 350mm (3.0-6.0HP class) standard optional part
the up to the compactness with
class) class) or 470mm (8.0 - 10.0HP ∙ Quiet operation level (as low as 22
192mm height
class) dB(A))

LINE UP OVERVIEW
∙ Drain-pump with 900mm lift as
COMPACT TYPE standard optional part
(BOTH AC MOTOR TYPE ∙ Quiet operation level (as low as
AND DC MOTOR TYPE 21dB(A))
AVAILABLE) ∙ Fan air flow rate up to 6 taps (DC
motor model only)
FLOOR
CONCEALED TYPE
CONCEALED & EXPOSED

FLOOR / CEILING
CONVERTIBLE TYPE
OTHERS

CEILING FLOOR CONCEALED TYPE FLOOR/CEILING CONVERTIBLE TYPE CEILING SUSPENDED TYPE WALL MOUNTED TYPE
SUSPENDED TYPE ∙ Visual aesthetics: it can be hidden ∙ Fully [Floor mounted] or ∙ Ideal for a higher ceiling location ∙ Simple installation procedure
away even when there is no ceiling [Ceiling suspended] installation for installation (up to 5.6m in ∙ Flexible discreet design suitable
void. Little installation space convertible cooling) to any interior
required thanks to only 220mm ∙ Easy installation ∙ Better power-saving with
WALL depth ∙ Fresh air-intake design optional Motion Sensor
MOUNTED TYPE ∙ Height just up to 620mm, suitable ∙ Optional drain pump available ∙ Quiet operation level (as low as
for installation beneath the 28dB(A)
window

COMPARING VENTILATIONS
COMPARING VENTILATIONS CAPACITY

Fan Air Flow Rate (m3/h) 200 300 400 500 650 800 1,000 1,080 1,250 1,500 1,680 2,000 2,100 2,500 3,000 4,000 5,000 6,000
ALL FRESH AIR UNIT

ALL FRESH AIR UNIT TOTAL HEAT EXCHANGER


∙ Creates a comfortable and healthy ∙ Creates a healthy indoor
indoor environment thanks to environment thanks to
TOTAL HEAT EXCHANGER introducing fresh air function and introducing fresh air function and
heat/cool function ventilation function
∙ Various controllers can be selected ∙ Remote controller for Total Heat
and interfaced with the H-LINK Exchanger is equipped in unit as
system standard part 31
∙ Longer ducts can be connected
on-site, thanks to the higher ESP 32

LINE UP OVERVIEW

FEATURES COMPARISON
4-WAY 4-WAY 2-WAY 1-WAY HIGH/MEDIUM/ (8/10HP class) SLIM TYPE COMPACT TYPE COMPACT TYPE FLOOR FLOOR/CEILING CEILING WALL MOUNTED TYPE
CASSETTE CASSETTE CASSETTE CASSETTE LOW ESP TYPE HIGH/MEDIUM (AC) (DC) CONCEALED CONVERTIBLE SUSPENDED
TYPE COMPACT TYPE TYPE TYPE ESP TYPE TYPE TYPE TYPE

Model
RPIH-HNAUNQ
RPI-FSNQ
RCI-FSKDNQ RCIM-FSN4 RCD-FSN3 RCS-FSN RPIM-HNAUNQ RPIZ-FSNQS/P RPIZ-HNATNQ RPIZ-HNDTSQ RPFI-FSNQ RPFC-FSNQ RPC-FSN3 RPK-FSNQS RPK-FSN4M
RPI-FSN3Q
RPIL-HNAUNQ

SET FREE Σ HNBQ series


Temperature Setting Rate °C(0.5/1)_°F(1) °C(0.5/1)_°F(1) °C(0.5/1)_°F(1) °C(0.5/1)_°F(1) 1°C/1°F 1°C/1°F 1°C/1°F 1°C/1°F 1°C/1°F 1°C/1°F 1°C/1°F °C(0.5/1)_°F(1) 1°C/1°F °C(0.5/1)_°F(1)

Indoor Fan Speed 4 taps 4 taps 4 taps 4 taps 3 taps 1 tap 3 taps 3 taps 6 taps 3 taps 3 taps 4 taps 3 taps 4 taps

Louver Direction 7 (*4) 7 (*4) 7 (*4) 7 (*5) - - - - - - 7 (*5) 7 (*5) 7 (*5) 7 (*5)

Individual Louver Setting - - - - - - - - - - -

COMFORT Auto Louver Setting - - - - - -

Cold Draft Prevention Availability (*1)

Dry mode Availability

Power Saving with Motion Sensor - - - - - - - - -

Peak cut control - - - - - - - -


Outdoor Unit
capacity control
moderate control - - - - - - - -

Indoor Unit Address - - - - - - - -


POWER-SAVING Indoor Unit
(*2) Rotation Control
Indoor Air Temperature difference - - - - - - - -

Automatic Fan Operation

Quick Function - - - - - - - -

Comfort setting Control Cool Air - - - - - - - -

Daylight Saving Time

LINE UP OVERVIEW
Power Consumption visualization - - - - - - - -
MENU
(*2) Weekly Schedule Setting

Power-Saving Setting - - - - - - - -

Dirty Filter Notice Availability

Sensor Condition Check (*9)

Model Display (*2) - - - - - - - - - -


Check Menu
MAINTENANCE Indoor / Outdoor PCB Check (*2)

Alarm History Display (*9)

Colored Decoration Panel availability - - (*6) (*6) - - - - - - - - - -

Motion Sensor PS-MSK2 SOR-NEC SOR-NED SOR-NES - - - - - - - SOR-NEP - -


HR4A10NEWQ PC-RLH11 PC-RLH11 PC-RLH11 PC-RLH11 PC-RLH11 PC-RLH11 PC-RLH11 (*10) PC-RLH11 (*10)
Receiver Kit for wireless remote controller PC-ALHC1 PC-ALHD1 PC-ALHS1 PC-ALHP1 PC-ALHZ1 (*11)
PC-ALH3 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1 PC-ALHZ1
DUPC-63K1
DUPI-131Q
Drain-up mechanism availability (*3) (*3) (*3) (*3) DUPI-15H2Q (*3) (*3) (*3) - - DUPC-71K1 - (*8)
DUPI-361Q
DUPC-160K1
OPTIONAL
Fresh air intake design (*7) (*7) (*7) (*7) - - - - - - - (*7) - -
ACCESSORY
KW-PP5Q KW-PP5Q
Air filter (*8) (*8) (*8) (*8) KW-PP7/8/9/10Q - - (*8) (*8) (*8) (*8) (*8)
KW-PP6Q KW-PP6Q
MSF-NP63A1
Strainer kit - - - - - - - - - - - - MSF-NP63A1
MSF-NP112A1

(*1) This function is utilized to prevent cold discharged air at start-up of heating (*6) 3 colors available except white (Beige, Grey and Black)
operation, after defrosting operation, etc. The fan speed automatically switches (*7) Optional parts: Duct Adapter is availbale. please consult your distributor.
from Slow to Low and then to the set fan speed. The fan operation might be
stopped for up to 2 minutes. At this time the louver is fixed horizontally. (*8) Please consult your distributor for the availability.

(*2) Advanced wired remote controller PC-ARF1 needs to be connected. (*9) PC-ARF1 or HCWA10NEGQ needs to be connected.

(*3) included as standard equipment (*10) Standard Receiver kit (PC-RLH11) is equipped with the unit in package as
standard optional part with Wireless Remote Controller (PC-LH3A)
(*4) 7 steps are avilable by individual louver setting. 5 steps only in the operation of
Cooling or Dry. (*11) Receiver Kit is installed in the unit as standard part. Please use Receiver Kit
(PC-ALHZ1) when receiver kit needs to be installed separately from unit.
(*5) 5 steps only in the operation of Cooling or Dry.
33

34
– –
4-WAY CASSETTE TYPE 4-WAY CASSETTE COMPACT TYPE

DIMENSIONS DIMENSIONS

RCI-1.0 FSKDNQ 20kg 840mm 570mm 570mm


840mm

RCIM-0.6~1.5 FSN4 16kg


RCI-1.5~2.0 FSKDNQ 21kg
238mm
280mm
RCIM-2.0~2.5 FSN4 17kg
RCI-2.5 FSKDNQ 22kg

P-AP56NAM 3kg
Decoration panel 6.5kg 950mm 950mm
620mm 620mm

SET FREE Σ HNBQ series


840mm 840mm

RCI-3.0~6.0 FSKDNQ 26kg


288mm
Decoration panel 6.5kg

950mm 950mm

FEATURES AND BENEFITS FEATURES AND BENEFITS


Adaptability Design Flexibility Adaptability Design Flexibility
1) Wide Detection area of 2) Control air flow with
Suitable for high ceiling space Top-class silent operation Compact
motion sensor(PS-MSK2) individual four-way louvers
(optional part) to achieve better more comfortable air conditioning Thanks to cooling air blow as quiet as gentle breeze Adaptation to 600×600mm ceilings
up to 5.5m down

CEILING CASSETTE
energy-saving can be achieved along each zone
requirement

Model RCI-1.0FSKDNQ RCI-1.5FSKDNQ RCI-2.0FSKDNQ RCI-2.5FSKDNQ RCI-3.0FSKDNQ RCI-4.0FSKDNQ RCI-5.0FSKDNQ RCI-6.0FSKDNQ Model RCIM-0.6FSN4 RCIM-0.8FSN4 RCIM-1.0FSN4 RCIM-1.5FSN4 RCIM-2.0FSN4 RCIM-2.5FSN4
Indoor Unit Power Supply AC 1Φ, 220-240V/50Hz, 220V/60Hz Indoor Unit Power Supply AC 1Φ, 230V 50Hz, 220-240V 50Hz, 220V 60Hz
Nominal Cooling kW 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0 Nominal Cooling kW 1.6 2.2 2.8 4.0 5.6 7.1
Capacity Heating kW 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0 Capacity Heating kW 1.9 2.5 3.2 4.8 6.3 8.5
Sound Pressure Sound Pressure
(Hi2/Hi/Me/Lo) dB(A) 33/30/28/27 35/31/30/27 37/32/30/27 42/36/32/28 42/36/32/28 48/43/39/33 48/45/40/35 48/46/41/37 (Hi2/Hi/Me/Lo) dB(A) 34/30/28/24.5 36/33/29/24.5 38/34/30/24.5 41/37/33/27.5 45/39/35/31 47/43/39/35
Level Level
Outer Dimension (H×W×D) mm 238×840×840 238×840×840 238×840×840 238×840×840 288×840×840 288×840×840 288×840×840 288×840×840 Outer Dimension (H×W×D) mm 280×570×570 280×570×570 280×570×570 280×570×570 280×570×570 280×570×570
Net Weight kg 20 21 21 22 26 26 26 26 Net Weight kg 16 16 16 16 17 17
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A Refrigerant R410A R410A R410A R410A R410A R410A
Indoor Fan Indoor Fan
(Hi2/Hi/Me/Lo) m3/min 15/13/11/9 21/17/14/11 22/17/14/11 27/23/18/14 27/23/18/14 37/31/24/20 37/33/26/21 37/35/28/22 (Hi2/Hi/Me/Lo) m3/min 10/8.5/7.5/6 11/9.5/8/6 12/10/8.5/6 13/11/9.5/7 15/12/10/8 16/14/12/10
Air Flow Rate Air Flow Rate
Connections Flare-Nut Connection (with flare Nuts) Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52
Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.21 0.21 0.21 0.21 0.25 0.25 0.25 0.25
Adaptable Panel Model P-AP56NAM (without Motion Sensor)
Adaptable Panel Model Included (without Motion Sensor) Color Neutral White
Color Neutral White Outer Dimension (H×W×D) mm 30×620×620
Outer Dimension (H×W×D) mm 40×950×950 Net Weight kg 3.0
Net Weight kg 6.5
NOTE:
Approximate Packing Volume m3 0.10 1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
NOTE: Cooling Operation Conditions Heating Operation Conditions
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions. Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
Cooling Operation Conditions Heating Operation Conditions 19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) Piping Length:7.5 metre Piping Length:7.5 metre
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) Piping Lift:0 metre Piping Lift:0 metre
Piping Length:7.5 metre Piping Length:7.5 metre 2. The sound pressure level is based on following conditions. 
Piping Lift:0 metre Piping Lift:0 metre 1.5 metre Beneath the Unit.
2. The sound pressure level is based on following conditions.  The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
1.5 metre Beneath the Unit.
35
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Decoration panel is included. 36
– –
2-WAY CASSETTE TYPE 1-WAY CASSETTE TYPE

DIMENSIONS DIMENSIONS

860mm 630mm
RCS-0.8~1.0 FSN 25kg
RCD-0.8~1.0 FSN3 23kg 900mm 720mm

298mm RCS-1.5~2.0 FSN 26kg


RCD-1.5~3.0 FSN3 25kg 235mm
30mm
35mm
P-AP36CNA 4.5kg
P-AP90DNA 7.5kg
710mm 1,100mm
800mm 1,100mm
P-AP56CNA 4.5kg

SET FREE Σ HNBQ series


630mm
1,420mm
1,210mm 720mm
RCD-4.0~6.0 FSN3 39kg

298mm RCS-2.5~3.0 FSN 33kg


P-AP160DNA 10.5kg 30mm
235mm
35mm
P-AP80CNA 6kg
1,660mm
710mm
800mm 1,410mm

FEATURES AND BENEFITS FEATURES AND BENEFITS


Adaptability Design Flexibility Adaptability Design Flexibility
1) Wide Detection area of motion 2) Control air flow with
Suitable for high ceiling space Quiet operation 3 installation types selectable
sensor (SOR-NED) individual louvers
(optional part) to achieve better energy- suitable environment can be achieved for Thanks to 4.6m cooling air blow down new design in fan inlet and fan resulted in ∙ Corner type (standard)
saving each person the low sound pressure ∙ Clipped ceiling (one-way) type

CEILING CASSETTE
∙ Clipped ceiling (two-way) type

Model RCD-0.8FSN3 RCD-1.0FSN3 RCD-1.5FSN3 RCD-2.0FSN3 RCD-2.5FSN3 RCD-3.0FSN3 RCD-4.0FSN3 RCD-5.0FSN3 RCD-6.0FSN3 Model RCS-0.8FSN RCS-1.0FSN RCS-1.5FSN RCS-2.0FSN RCS-2.5FSN RCS-3.0FSN
Indoor Unit Power Supply AC 1Φ, 220-240V/50Hz, 220V/60Hz Indoor Unit Power Supply AC 1Φ, 220-240V/50Hz, 230V/50Hz, 220V/60Hz
Nominal Cooling kW 2.2 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0 Nominal Cooling kW 2.2 2.8 4.0 5.6 7.1 8.0
Capacity Heating kW 2.5 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0 Capacity Heating kW 2.5 3.2 4.8 6.3 8.5 9.0
Sound Pressure Sound Pressure
(Hi2/Hi/Me/Lo) dB(A) 30/29/28/27 31/29/28/27 37/34/31/30 39/36/33/30 42/39/36/33 45/42/38/33 43/40/37/34 47/44/41/35 48/45/42/39 (Hi2/Hi/Me/Lo) dB(A) 34/32/29/27 36/34/31/28 40/37/33/31 42/38/35/31 43/39/36/32 43/40/37/33
Level Level
Outer Dimension (H×W×D) mm 298×860×630 298×860×630 298×860×630 298×860×630 298×860×630 298×860×630 298×1,420×630 298×1,420×630 298×1,420×630 Outer Dimension (H×W×D) mm 235×900×720 235×900×720 235×900×720 235×900×720 235×1,210×720 235×1,210×720
Net Weight kg 23 23 25 25 25 25 39 39 39 Net Weight kg 25 25 26 26 33 33
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A Refrigerant R410A R410A R410A R410A R410A R410A
Indoor Fan 16.5/14.5 18.5/16.5 21/18.5/16 37/32.5/28.5 Indoor Fan
(Hi2/Hi/Me/Lo) m3/min 10/9/7.5/6.5 11/9.5/8.5/7 15/13/11.5/10 30/26.5/23/20 35/31/27/21 (Hi2/Hi/Me/Lo) m3/min 8.5/7.5/6.5/6 9.5/8.5/7.5/6.5 13/11.5/10/8.5 14.5/13/11/9.5 18.5/16.5/14.5/12.5 20/17.5/15.5/13
Air Flow Rate /12.5/10.5 /14.5/12.5 /12.5 /24 Air Flow Rate
Connections Flare-Nut Connection (with Flare Nuts) Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.24 0.24 0.24 0.24 0.24 0.24 0.36 0.36 0.36 Approximate Packing Volume m3 0.25 0.25 0.25 0.25 0.32 0.32

Adaptable Panel Model P-AP90DNA (for RCD- [0.8-3.0] FSN3) P-AP160DNA (for RCD- [4.0-6.0] FSN3) Adaptable Panel Model P-AP36CNA (for RCS-[0.8-1.0]FSN) P-AP56CNA (for RCS-[1.5-2.0]FSN) P-AP80CNA (for RCS-[2.5-3.0]FSN)
Color Neutral White Neutral White Color Neutral White Neutral White Neutral White
Outer Dimension (H×W×D) mm 30×1,100×710 30×1,660×710 Outer Dimension (H×W×D) mm 35×1,100×800 35×1,100×800 35×1,410×800
Net Weight kg 7.5 10.5 Net Weight kg 4.5 4.5 6.0
Approximate Packing Volume m3 0.13 0.20
NOTE:
NOTE: 1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions. Cooling Operation Conditions Heating Operation Conditions
Cooling Operation Conditions Heating Operation Conditions Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) 19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB)
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) Piping Length:7.5 metre Piping Length:7.5 metre
Piping Length:7.5 metre Piping Length:7.5 metre Piping Lift:0 metre Piping Lift:0 metre
Piping Lift:0 metre Piping Lift:0 metre 2. The sound pressure level is based on following conditions. 
2. The sound pressure level is based on following conditions.  1.5 metre Beneath the Unit. 37
1.5 metre Beneath the Unit. The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. 38
– –
DUCTED HIGH ESP (EXTERNAL STATIC PRESSURE) TYPE

Model RPIH-3.0HNAUNQ RPIH-3.3HNAUNQ RPIH-4.0HNAUNQ RPIH-5.0HNAUNQ RPIH-6.0HNAUNQ

Indoor Unit Power Supply AC 1 Φ, [220-240V/50Hz]

Cooling kW 8.4 9.0 11.2 14.2 16.0


Nominal
Capacity
Heating kW 9.6 10.0 13.0 16.3 18.0

Sound Pressure
COMPACT TYPE (Hi/Me/Lo) dB(A) 42/39/34 42/39/34 43/39/34 44/41/37 48/42/37
Type HIGH ESP TYPE MEDIUM ESP TYPE LOW ESP TYPE SLIM TYPE
(AC MOTOR / DC MOTOR)
Level
Outer
RPIH-(3.0~6.0)HNAUNQ RPIM-(0.8~2.5)HNAUNQ RPIZ-(0.8~2.5)HNATNQ (H×W×D) mm 300×1,175×800 300×1,175×800 300×1,175×800 300×1,475×800 300×1,475×800
Model RPI-(8.0~10.0)FSNQ RPI-(8.0~10.0)FSN3Q
RPIL-(0.8~6.0)HNAUNQ RPIZ-(0.8~1.5)FSNQS/P
RPIZ-(0.8~2.5)HNDTSQ
Dimension

Cooling kW 8.4 – 28.0 2.2 – 28.0 2.2 – 16.0 2.2 – 4.3 2.2 – 7.1 Net Weight kg 45 45 45 53 54
Capacity
Heating kW 9.6 – 31.5 2.8 – 31.5 2.8 – 18.0 2.8 – 4.9 2.5 – 8.0 Refrigerant R410A R410A R410A R410A R410A
Height mm 300 – 470 270 – 470 270 – 300 192 192
Indoor Fan

SET FREE Σ HNBQ series


Dimensions Width mm 1,060 – 1,475 725 – 1,250 725-1,475 700 700 – 1,180 (Hi/Me/Lo) m3/min 30/28/23 30/28/23 30/28/23 35.5/32/27 41/33/26
Air Flow Rate
Depth mm 800 – 1,120 720 – 1,120 720-800 602 447 External Static Pressure *3) Pa 120(90) 120(90) 120(90) 120(90) 120(90)
Net Weight kg 45 – 104 24 – 106 24 – 54 21 17 – 28
Connections Flare-Nut Connection (with Flare Nuts)

Refrigerant Liquid Line mm Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52


Piping
Diameter Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
FEATURES AND BENEFITS Condensate Drain VP25 VP25 VP25 VP25 VP25

High ESP type Slim type Approximate Packing Volume m3


0.40 0.40 0.40 0.49 0.49
∙ High ESP (90/120Pa for 3.0-6.0 HP class, 180Pa for 8.0- ∙ Ideal for narrow ceiling voids installation thanks to low
10.0 HP class) height up to 192mm & width just 700mm
∙ Space saving design thanks to a height of only 300mm ∙ Drain-pump with 900mm lift as standard optional part Model RPI-8.0FSNQ RPI-10.0FSNQ

(3.0 - 6.0 HP class) or 470mm (8.0-10.0HP class) ∙ Quiet operation level (as low as 22dB(A)) Indoor Unit Power Supply AC 3 Φ, [380-415V/50Hz]

Medium ESP type Compact type Cooling kW 22.4 28.0


Nominal
Capacity
∙ 2 steps of medium ESP (50/80Pa for 0.8- 2.5 HP class, ∙ Ideal for installation over the closet or windows thanks Heating kW 25.0 31.5
100Pa for 8.0-10.0 HP class) to the up to the compactness with 192mm height
Sound Pressure Level dB(A) 50 52
∙ Space saving design thanks to a height of only 270mm ∙ Drain-pump with 900mm lift as standard optional part
Outer
(0.8 - 2.5HP class) or 470mm (8.0 - 10.0HP class) ∙ Quiet operation level (as low as 21dB(A)) Dimension
(H×W×D) mm 470×1,060×1,120 470×1,250×1,120

∙ Fan air flow rate up to 6 taps (DC motor model only) Net Weight kg 96 104

DUCTED
Low ESP type
∙ Low ESP (30Pa for 0.8-2.5 HP class, 60Pa for 3.0-6.0 HP Refrigerant R410A R410A

class) Indoor Fan Air Flow Rate 3


m /min 58 72
∙ Space saving design thanks to a height of only 270mm
External Static Pressure *3) Pa 180 180
(0.8-2.5HP class) or 350mm (3.0-6.0HP class)
Connections Brazing

Refrigerant Liquid Line mm Φ9.52 Φ9.52


Piping
Diameter Gas Line mm Φ19.05 Φ22.23

Condensate Drain VP25 VP25

Approximate Packing Volume m3 0.90 1.06

NOTE:
1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under the following
conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB)
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre
2. The sound pressure level is based on following conditions.
1.4 metre Beneath the Unit.
With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
Voltage of the power source for the indoor fan motor is 220V.
(In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is not used.

39

40
– –
MEDIUM ESP (EXTERNAL STATIC PRESSURE) TYPE LOW ESP (EXTERNAL STATIC PRESSURE) TYPE

Model RPIM-0.8HNAUNQ RPIM-1.0HNAUNQ RPIM-1.3HNAUNQ RPIM-1.5HNAUNQ RPIM-1.8HNAUNQ Model RPIL-0.8HNAUNQ RPIL-1.0HNAUNQ RPIL-1.3HNAUNQ RPIL-1.5HNAUNQ RPIL-1.8HNAUNQ RPIL-2.0HNAUNQ RPIL-2.3HNAUNQ

Indoor Unit Power Supply AC 1 Φ, [220-240V/50Hz] Indoor Unit Power Supply AC 1 Φ, [220-240V/50Hz]

Cooling kW 2.2 2.8 3.6 4.3 5.0 Cooling kW 2.2 2.8 3.6 4.3 5.0 5.6 6.3
Nominal Nominal
Capacity Capacity
Heating kW 2.8 3.3 4.2 4.9 5.6 Heating kW 2.8 3.3 4.2 4.9 5.6 6.5 7.5

Sound Pressure Sound Pressure


(Hi/Me/Lo) dB(A) 32/27/24 32/27/24 35/33/28 35/33/28 35.5/33/28 (Hi/Me/Lo) dB(A) 28/25/22 28/25/22 34/32/30 34/32/30 34/32/29 34/32/29 36.5/30.5/25
Level Level
Outer Outer
(H×W×D) mm 270×725×720 270×725×720 270×725×720 270×725×720 270×975×720 (H×W×D) mm 270×725×720 270×725×720 270×725×720 270×725×720 270×975×720 270×975×720 270×975×720
Dimension Dimension

Net Weight kg 24 24 25 25 31 Net Weight kg 24 24 25 25 31 31 32

Refrigerant R410A R410A R410A R410A R410A Refrigerant R410A R410A R410A R410A R410A R410A R410A

Indoor Fan Indoor Fan

SET FREE Σ HNBQ series


(Hi/Me/Lo) m3/min 10/8/7 10/8/7 12/11/9 12/11/9 16/14/11.5 (Hi/Me/Lo) m3/min 9/8/7 9/8/7 13/11/9 13/11/9 15/14/12 15/14/12 21/17/11
Air Flow Rate Air Flow Rate

External Static Pressure *3) Pa 50(80) 50(80) 50(80) 50(80) 50(80) External Static Pressure (*3) Pa 30 30 30 30 30 30 30

Connections Flare-Nut Connection (with Flare Nuts) Connections Flare-Nut Connection (with Flare Nuts)

Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52
Piping Piping
Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88

Condensate Drain VP25 VP25 VP25 VP25 VP25 Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25

3 3
Approximate Packing Volume m 0.22 0.22 0.22 0.22 0.28 Approximate Packing Volume m 0.22 0.22 0.22 0.22 0.28 0.28 0.28

Model RPIM-2.0HNAUNQ RPIM-2.3HNAUNQ RPIM-2.5HNAUNQ RPI-8.0FSN3Q RPI-10.0FSN3Q Model RPIL-2.5HNAUNQ RPIL-3.0HNAUNQ RPIL-3.3HNAUNQ RPIL-4.0HNAUNQ RPIL-5.0HNAUNQ RPIL-6.0HNAUNQ

Indoor Unit Power Supply AC 1 Φ, [220-240V/50Hz] AC 3 Φ, [380-415V/50Hz] Indoor Unit Power Supply AC 1 Φ, [220-240V/50Hz]

Cooling kW 5.6 6.3 7.1 22.4 28.0 Cooling kW 7.1 8.4 9.0 11.2 14.2 16.0
Nominal Nominal
Capacity Capacity
Heating kW 6.5 7.5 8.5 25.0 31.5 Heating kW 8.5 9.6 10.0 13.0 16.3 18.0

Sound Pressure Sound Pressure


(Hi/Me/Lo) dB(A) 35.5/33/28 39/34/26 39/34/26 50 52 (Hi/Me/Lo) dB(A) 36.5/30.5/25 38/30/24 38/30/24 38/35/31 44/39/35 46/41/35
Level Level
Outer Outer
(H×W×D) mm 270×975×720 270×975×720 270×975×720 470×1,060×1,120 470×1,250×1,120 (H×W×D) mm 270×975×720 300×1,175×800 300×1,175×800 300×1,175×800 300×1,475×800 300×1,475×800
Dimension Dimension

Net Weight kg 31 32 32 96 104 Net Weight kg 32 45 45 45 53 54

DUCTED
Refrigerant R410A R410A R410A R410A R410A Refrigerant R410A R410A R410A R410A R410A R410A

Indoor Fan 3 Indoor Fan 3


(Hi/Me/Lo) m /min 16/14/11.5 20/16/11.5 20/16/11.5 58(56*) 72(70*) (Hi/Me/Lo) m /min 21/17/11 29/25/21 29/25/21 29/25/21 36/31/26 42/34/26
Air Flow Rate Air Flow Rate

External Static Pressure *3) Pa 50(80) 50(80) 50(80) 100 100 External Static Pressure (*3) Pa 30 60 60 60 60 60

Connections Flare-Nut Connection (with Flare Nuts) Brazing Connections Flare-Nut Connection (with Flare Nuts)

Refrigerant Liquid Line mm Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Refrigerant Liquid Line mm Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Piping Piping
Diameter Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ19.05 Φ22.23 Diameter Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88

Condensate Drain VP25 VP25 VP25 VP25 VP25 Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25

Approximate Packing Volume m3 0.28 0.28 0.28 0.90 1.06 Approximate Packing Volume m3 0.28 0.40 0.40 0.40 0.49 0.49

NOTE:
NOTE: 1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under the following
1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
conditions.
Cooling Operation Conditions Heating Operation Conditions
Cooling Operation Conditions Heating Operation Conditions Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) 19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB)
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) Piping Length:7.5 metre Piping Length:7.5 metre
Piping Length:7.5 metre Piping Length:7.5 metre Piping Lift:0 metre Piping Lift:0 metre
Piping Lift:0 metre Piping Lift:0 metre
2. The sound pressure level is based on following conditions.
2. The sound pressure level is based on following conditions. 1.4 metre Beneath the Unit.
1.4 metre Beneath the Unit. With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
With Discharge Duct (2.0 metre) and Return Duct (1.0 metre). Voltage of the power source for the indoor fan motor is 220V.
Voltage of the power source for the indoor fan motor is 220V. (In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
(In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).) The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is not used.
3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is not used.
41

42
– –
SLIM TYPE COMPACT TYPE
(BOTH AC MOTOR TYPE AND DC MOTOR TYPE AVAILABLE)
Model RPIZ-0.8FSNQS/P RPIZ-1.0FSNQS/P RPIZ-1.3FSNQS/P RPIZ-1.5FSNQS/P

RPIZ- RPIZ- RPIZ- RPIZ- RPIZ- RPIZ- RPIZ- RPIZ-


Indoor Unit Power Supply AC 1Φ, [220-240V 50Hz]
Model (AC MOTOR) 0.8HNATNQ 1.0HNATNQ 1.3HNATNQ 1.5HNATNQ 1.8HNATNQ 2.0HNATNQ 2.3HNATNQ 2.5HNATNQ
Indoor Unit Power Supply AC 1 Φ, [220-240V/50Hz]

Cooling kW 2.2 2.8 3.6 4.3 Cooling kW 2.2 2.8 3.6 4.0 5.0 5.6 6.3 7.1
Nominal
Nominal
Capacity
Capacity Heating kW 2.5 3.2 4.0 4.5 5.6 6.3 7.1 8.0
Heating kW 2.8 3.3 4.2 4.9 Sound Pressure
(Hi/Me/Lo) dB(A) 30/23/20 30/23/20 34/25/22 32.5/26/23 34/26/25 34/26/25 37/29/27 37/29/27
Level
Sound Pressure Outer
(Hi/Me/Lo) dB(A) 28/25/22 28/25/22 32/30/28 32/30/28 (H×W×D) mm 192×700×447 192×700×447 192×700×447 192×910×447 192×1,180×447 192×1,180×447 192×1,180×447 192×1,180×447
Level Dimension
Net Weight kg 17 17 17 21 27 27 28 28
Outer
(H×W×D) mm 192×700×602 192×700×602 192×700×602 192×700×602
Dimension Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A
Indoor Fan 3

SET FREE Σ HNBQ series


(Hi/Me/Lo) m /min 9.5/6.5/5.5 9.5/6.5/5.5 9.5/6.5/5.5 10/7/6 15/10/9 15/10/9 17/10/9 17/10/9
Net Weight kg 21 21 21 21 Air Flow Rate
External Static Pressure (*3) Pa 10(30) 10(30) 10(30) 10(30) 10(30) 10(30) 10(30) 10(30)

Refrigerant R410A R410A R410A R410A Connections Flare-Nut Connection (with Flare Nuts)

Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
Indoor Fan Piping
(Hi/Me/Lo) m3/min 8/7/6 8/7/6 10/8/7 10/8/7
Air Flow Rate Diameter Gas Line mm Φ12.70 Φ12.70 Φ12.70 Φ12.70 Φ15.88 Φ15.88 Φ15.88 Φ15.88
External Static Standard Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Pa 10(10/30) 10(10/30) 10(10/30) 10(10/30)
Pressure (min/max)
Approximate Packing Volume m3 0.142 0.142 0.142 0.15 0.18 0.18 0.18 0.18
Connections Flare-Nut Connection (with Flare Nuts)

Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35


Refrigerant RPIZ- RPIZ- RPIZ- RPIZ- RPIZ- RPIZ- RPIZ- RPIZ-
Piping Model (DC MOTOR) 0.8HNDTSQ 1.0HNDTSQ 1.3HNDTSQ 1.5HNDTSQ 1.8HNDTSQ 2.0HNDTSQ 2.3HNDTSQ 2.5HNDTSQ
Diameter
Gas Line mm Φ12.70 Φ12.70 Φ12.70 Φ12.70 Indoor Unit Power Supply AC 1 Φ, [220-240V/50Hz] [220V/60Hz]

Cooling kW 2.2 2.8 3.6 4.0 5.0 5.6 6.3 7.1


Condensate Drain VP25 VP25 VP25 VP25 Nominal
Capacity
Heating kW 2.5 3.2 4.0 4.5 5.6 6.3 7.1 8.0

Approximate Packing Volume m 3


0.15 0.15 0.15 0.15 Sound Pressure 33/31/28/ 33/31/28/ 33/31/28/ 31/30/28/ 36/33.5/31/ 36/33.5/31/ 36/33.5/31/ 36/33.5/31/
(6taps) dB(A)
Level 25/23.5/22.5 25/23.5/22.5 25/23.5/22.5 25/22/20 28/24.5/22.5 28/24.5/22.5 28/24.5/22.5 28/24.5/22.5
Outer
(H×W×D) mm 192×700×447 192×700×447 192×700×447 192×910×447 192×1,180×447 192×1,180×447 192×1,180×447 192×1,180×447
Dimension
NOTE:
1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under the following Net Weight kg 17 17 17 20 24 24 24 24
conditions.
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A

DUCTED
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) Indoor Fan 3 10/9/8/7.5/ 16.5/15/13/ 16.5/15/13/ 16.5/15/13/ 16.5/15/13/
(6taps) m /min 8.5/8/7/6/5.5/5 8.5/8/7/6/5.5/5 8.5/8/7/6/5.5/5
Air Flow Rate 6.5/6 12/10/9 12/10/9 12/10/9 12/10/9
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) External Static Pressure (*3) Pa 10(0-10-30) 10(0-10-30) 10(0-10-30) 10(0-10-30) 10(0-10-50) 10(0-10-50) 10(0-10-50) 10(0-10-50)
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre Connections Flare-Nut Connection (with Flare Nuts)

2. The sound pressure level is based on following conditions. Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.52 Φ9.52
1.4 metre Beneath the Unit. Piping
With Discharge Duct (2.0 metre) and Return Duct (1.0 metre). Diameter Gas Line mm Φ12.70 Φ12.70 Φ12.70 Φ12.70 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Voltage of the power source for the indoor fan motor is 220V.
(In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).) Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. 3
Approximate Packing Volume m 0.142 0.142 0.142 0.15 0.18 0.18 0.18 0.18
3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is not used.

NOTE:
1. The cooling capacities above show the maximum capacities when the outdoor and indoor temperature are under the following
conditions.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB)
Piping Length:7.5 metre Piping Length:7.5 metre
Piping Lift:0 metre Piping Lift:0 metre
2. The sound pressure level is based on following conditions.
1.4 metre Beneath the Unit.
With Discharge Duct (2.0 metre) and Return Duct (1.0 metre).
Voltage of the power source for the indoor fan motor is 220V.
(In case of the power source of 240V, the sound pressure level increases by about 1~2dB(A).)
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The data for external pressure (*3) indicates "Standard Pressure Setting values when a filter is not used.

43

44
– –
FLOOR CONCEALED TYPE FLOOR / CEILING CONVERTIBLE TYPE

DIMENSIONS DIMENSIONS

RPFI-1.0FSNQ 25kg RPFC-1.8~2.0FSNQ 31kg


680mm
620mm
230mm
RPFI-1.5FSNQ 26kg RPFC-2.3~2.5FSNQ 32kg
900mm 202mm 990mm

RPFC-3.0FSNQ 39kg

680mm

SET FREE Σ HNBQ series


RPFC-3.3FSNQ 40kg
230mm
RPFI-2.0~2.5FSNQ 34kg 620mm
1,285mm
RPFC-4.0FSNQ 41kg
1,170mm
202mm

680mm
RPFC-5.0FSNQ 47kg
230mm

FEATURES AND BENEFITS


1,580mm

Design Flexibility Air Outlet


FEATURES AND BENEFITS
• Blends unobtrusively with any interior décor: only the Cavity that
conceals
suction and discharge grilles are visible. the unit Adapts to both floor and ceiling New air-intake design
• Its low height (only 620mm) enables the unit to fit
⟦CEILING USE⟧ ⟦FLOOR USE⟧ Equipped with air-intakes, the unit
perfectly beneath a window.

620mm
• Supplies air to a wide area. • Smaller footprint: Only 230mm in depth. connects with ventilations such as a Total
• Requires little installation space thanks to its slim
• High ceiling use capability. • Suitable for installation beneath a Heat Exchanger using a duct, providing
202mm depth.
window thanks to the 680mm height. better interior air quality.
900-1,170mm
Air Inlet

EXPOSED & CONCEALED


202mm
Model RPFC-1.8FSNQ RPFC-2.0FSNQ RPFC-2.3FSNQ RPFC-2.5FSNQ RPFC-3.0FSNQ RPFC-3.3FSNQ RPFC-4.0FSNQ RPFC-5.0FSNQ

Indoor Unit Power Supply AC 1Φ, 220-240V 50Hz, 220V 60Hz


Model RPFI-1.0FSNQ RPFI-1.5FSNQ RPFI-2.0FSNQ RPFI-2.5FSNQ
Cooling kW 5.0 5.6 6.3 7.4 8.4 9.0 11.2 14.2
Indoor Unit Power Supply AC 1Φ , 220-240V/50Hz Nominal
Capacity
Heating kW 5.6 6.5 7.5 8.5 9.6 10.0 13.0 16.3
Cooling kW 2.8 4.3 5.6 7.1
Nominal
Capacity Ceiling Mode dB(A) 39/35/30 39/35/30 45/41/37 45/41/37 43/39/34 45/40/36 51/46/40 50/46/42
Heating kW 3.3 4.9 6.5 8.5 Sound Pressure
Level
Floor Mode dB(A) 43/38/35 43/38/35 48/44/40 48/44/40 46/41/37 48/43/39 54/49/43 55/50/46
Sound Pressure
(Hi/Me/Lo) dB(A) 37/34/31 40/38/35 42/38/36 45/43/40
Level
Outer Dimension (H×W×D) mm 230×990×680 230×990×680 230×990×680 230×990×680 230×1,285×680 230×1,285×680 230×1,285×680 230×1,580×680
Outer Dimension (H×W×D) mm 620×900×202 620×900×202 620×1,170×202 620×1,170×202
Net Weight kg 31 31 32 32 39 40 41 47
Net Weight kg 25 26 34 34
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant R410A R410A R410A R410A
Indoor Fan 3
(Hi/Me/Lo) m /h 780/660/540 780/660/540 966/840/678 966/840/678 1,092/912/732 1,164/978/798 1,488/1,230/978 1,980/1,680/1,380
Indoor Fan Air Flow Rate
(Hi/Me/Lo) m3/min 8.5/7/6 12/8/7 16/12.5/10.5 16/14/11
Air Flow Rate
Connections Flare-Nut Connection (with Flare Nuts)
Connections Flare-Nut Connection (with Flare Nuts)
Liquid Line mm Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52
Refrigerant
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ9.52 Piping Diameter
Refrigerant Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Piping Diameter
Gas Line mm Φ12.70 Φ12.70 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Condensate Drain VP25 VP25 VP25 VP25
Approximate Packing Volume m3 0.31 0.31 0.31 0.31 0.40 0.40 0.40 0.48
Approximate Packing Volume m3 0.19 0.19 0.23 0.23
NOTE:
NOTE: 1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions.
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions. Cooling Operation Conditions Heating Operation Conditions
Cooling Operation Conditions Heating Operation Conditions Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) 19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB)
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) Piping Length:7.5 metre Piping Length:7.5 metre
Piping Length:7.5 metre Piping Length:7.5 metre Piping Lift:0 metre Piping Lift:0 metre
Piping Lift:0 metre Piping Lift:0 metre 2. The sound pressure level is based on following conditions.
2. The sound pressure level is based on following conditions.  1.0 metre Beneath the unit.
1.0 metre from the unit. 1.0 metre from Discharge grille. 45
1.0 metre from inlet grille. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
The data in the table above was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure. 46
– –
CEILING SUSPENDED TYPE WALL MOUNTED TYPE

DIMENSIONS DIMENSIONS
220mm
780mm

960mm 280mm
690mm RPK-0.8-1.5FSNQS 10kg
RPC-1.5 FSN3 26kg

235mm
RPC-2.0 FSN3 27kg
220mm
1,050mm

1,270mm
690mm
290mm
RPK-1.8-2.3FSNQS 12.5kg

SET FREE Σ HNBQ series


RPC-2.5~3.0 FSN3 35kg 235mm

260mm
1,100mm
1,580mm 690mm

RPK-2.5-4.0FSN4M 15kg 300mm


RPC-4.0~6.0 FSN3 41kg 235mm

FEATURES AND BENEFITS


Simple installation procedure Flexible design suitable for any décor Easy maintenance
FEATURES AND BENEFITS Refrigerant piping can be connected from With smooth flat covers, the units match most Front flat panel keeps the unit from dust and
Adaptability Design Flexibility the rear, base, or left of the unit, providing modern interiors. Their compact size enables facilitates maintenance work. The front grille
much greater flexibility for piping and them to blend in, even in small spaces. hinges open easily—no tools are needed to
1) Wide Detection area of motion
2) Auto louver Suitable for high ceiling space selection of installation sites. gain quick access to the filter. The filter can
sensor (SOR-NEP)
be removed and cleaned as required.
(optional part) to achieve better energy- • S often the discomfort by temperature thanks to 5.6m cooling air blow down
saving irregularity and cold draft
Type Expansion Valve built-in type

EXPOSED & CONCEALED


Model RPK-0.8FSNQS RPK-1.0FSNQS RPK-1.3FSNQS RPK-1.5FSNQS RPK-1.8FSNQS RPK-2.0FSNQS RPK-2.3FSNQS
Indoor Unit Power Supply AC 1Φ, 220-240V/50Hz
Model RPC-1.5FSN3 RPC-2.0FSN3 RPC-2.5FSN3 RPC-3.0FSN3 RPC-4.0FSN3 RPC-5.0FSN3 RPC-6.0FSN3 Nominal Cooling kW 2.2 2.8 3.6 4.0 5.0 5.6 6.3
Capacity Heating kW 2.5 3.3 4.0 4.5 5.6 6.3 7.1
Indoor Unit Power Supply AC 1Φ, 220-240V/50Hz, 220V/60Hz
Sound Pressure
(Hi2/Hi/Me/Lo) dB(A) 35/32/31/29 39/35/32/30 39/35/32/30 46/40/36/33 39/35/32/30 46/40/36/33 42/40/38/33
Level
Cooling kW 4.0 5.6 7.1 8.0 11.2 14.0 16.0
Nominal Color White
Capacity
Heating kW 4.8 6.3 8.5 9.0 12.5 16.0 18.0 Outer Dimension (H×W×D) mm 280×780×220 280×780×220 280×780×220 280×780×220 290×1,050×220 290×1,050×220 290×1,050×220
Sound Pressure Net Weight kg 10 10 10 10 12.5 12.5 12.5
(Hi2/Hi/Me/Lo) dB(A) 37/35/31/28 38/35/31/28 38/35/31/28 40/37/33/29 44/42/37/32 48/45/41/35 49/47/42/36
Level Refrigerant R410A R410A R410A R410A R410A R410A R410A
Color Neutral White Indoor Fan
(Hi/Me/Lo) m3/min 8.5/7.5/6.5 8.5/7.5/6.5 9.2/7.5/6.7 10/8.5/7.5 12/10.3/8.7 12/10.3/8.7 13.7/12/10.3
Air Flow Rate
Outer Dimension (H×W×D) mm 235×960×690 235×960×690 235×1,270×690 235×1,270×690 235×1,580×690 235×1,580×690 235×1,580×690 Connections Flare-Nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35
Net Weight kg 26 27 35 35 41 41 41
Piping Diameter Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ12.7
Refrigerant R410A R410A R410A R410A R410A R410A R410A Condensate Drain VP16 VP16 VP16 VP16 VP16 VP16 VP16
Indoor Fan 3
Approximate Packing Volume m3 0.12 0.12 0.12 0.12 0.16 0.16 0.16
(Hi2/Hi/Me/Lo) m /min 15/13/11/9 15/13/11/9 19/16.5/14/11.5 21/18.5/15.5/12.5 30/26.5/22/17 35/31/25.5/20 37/32.5/27/21
Air Flow Rate
Connections Flare-Nut Connection (with Flare Nuts) Type Expansion valve built-in type NOTE:
1. The cooling and heating capacities above show the maximum capacities when

Refrigerant
Liquid Line mm Φ6.35 Φ6.35 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Φ9.52 Model RPK-2.5FSN4M RPK-3.0FSN4M RPK-4.0FSN4M the outdoor and indoor temperature are under the following conditions.
Cooling Operation Conditions
Piping Diameter Indoor Unit Power Supply AC 1Φ, [220-240V 50Hz]
Gas Line mm Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB)
Nominal Cooling kW 7.1 8.0 11.2 19.0ᵒC WB (66.2ᵒF WB)
Condensate Drain VP20 VP20 VP20 VP20 VP20 VP20 VP20 Capacity Heating kW 8.5 9.0 12.5 Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB)
Sound Pressure Piping Length:7.5 metre
Approximate Packing Volume m3 0.23 0.23 0.31 0.31 0.38 0.38 0.38 (Hi2/Hi/Me/Lo) dB(A) 45/42/38/35 47/44/40/35 51/48/44/39
Level Piping Lift:0 metre
Color White Heating Operation Conditions
NOTE:
1. The cooling and heating capacities above show the maximum capacities when the outdoor and indoor temperature are under the following conditions. Outer Dimension (H×W×D) mm 300×1,100×260 300×1,100×260 300×1,100×260 Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB)
Cooling Operation Conditions Heating Operation Conditions Net Weight kg 15 15 15 Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB)
Indoor Air Inlet Temperature: 27ᵒC DB (80ᵒF DB) Indoor Air Inlet Temperature: 20ᵒC DB (68ᵒF DB) Refrigerant R410A R410A R410A 6ᵒC WB (43ᵒF WB)
19.0ᵒC WB (66.2ᵒF WB) Outdoor Air Inlet Temperature: 7ᵒC DB (45ᵒF DB) Indoor Fan Piping Length:7.5 metre
Outdoor Air Inlet Temperature: 35ᵒC DB (95ᵒF DB) 6ᵒC WB (43ᵒF WB) (Hi2/Hi/Me/Lo) m3/min 18.5/16.5/14/12 20/17.5/15.5/12.5 23/20/17.5/14.5 Piping Lift:0 metre
Air Flow Rate
Piping Length:7.5 metre Piping Length:7.5 metre Motor W 38 38 38 2. The sound pressure level is based on following conditions.
Piping Lift:0 metre Piping Lift:0 metre Connections Flare-Nut Connection (with Flare Nuts) 1.0 metre Beneath the unit.
2. The sound pressure level is based on following conditions.  Liquid Line mm Φ9.52 Φ9.52 Φ9.52 1.0 metre from Discharge grille.
Refrigerant
1.0 metre Beneath the unit. Piping Diameter Gas Line The above data was measured in an anechoic chamber so that reflected
mm Φ15.88 Φ15.88 Φ15.88
1.0 metre from Discharge grille. sound should be taken into consideration in the field. 47
Condensate Drain VP16 VP16 VP16 When bottom air inlet is adopted, sound pressure will increase according
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
When bottom air inlet is adopted, sound pressure will increase according to factors such as installation mode and the room structure. Approximate Packing Volume m3 0.14 0.14 0.14 to factors such as installation mode and the room structure. 48

VENTILATION

ALL FRESH AIR UNIT TOTAL HEAT EXCHANGER


Model RPI-5.0KFNQ RPI-8.0KFNQ RPI-10.0KFNQ RPI-12.0KFNQ Model KPI-
20H-A-GQ
KPI-
30H-A-GQ
KPI-
40H-A-GQ
KPI-
50H-A-GQ
KPI-
65H-A-GQ
KPI-
80H-A-GQ
KPI-
100H-A-GQ
KPI-
125H-A-GQ
AC 3Φ
Unit Power Supply AC 1Φ, 220-240V/50Hz Unit Power Supply AC 1Φ, 220 50Hz
380-415V/50Hz
Cooling kW 14.0 22.4 28.0 33.5 Summer
Nominal % 64/64/70 60/60/65 61/61/66 60/60/62 65/65/69 65/65/69 65/65/69 65/65/69
Temp. (Hi/Me/Lo)
Capacity Efficiency
Heating kW 13.7 21.9 24.5 26.8 Winter
% 80/80/83 77/77/80 79/79/81 75/75/76 75/75/78 74/74/78 72/72/76 70/70/78
(Hi/Me/Lo)
Sound Pressure Level dB(A) 42 44 47 56 Summer
% 69/69/76 63/63/70 64/64/69 63/63/65 57/57/60 60/60/63 58/58/63 53/53/61
Outer Enthalpy (Hi/Me/Lo)
(H×W×D) mm 370 × 1,320 ×800 486 × 1,270 ×1,069 486 × 1,270 ×1,069 486 × 1,270 ×1,069 Efficiency Winter
Dimensions % 75/75/78 70/70/75 70/70/75 69/69/71 65/65/70 70/70/72 66/66/69 63/63/72
(Hi/Me/Lo)
Net Weight kg 63 110 110 110
Sound Pressure

SET FREE Σ HNBQ series


(Hi/Me/Lo) dB(A) 32/30/25 36/34/28 39/37/30 40/38/31 40/38/35 40/38/34 43/42/34 42/40/37
Refrigerant R410A R410A Level
Outer
(H×W×D) mm 220×962×735 220×962×735 220×1,112×735 220×1,112×735 388×1,119×884 388×1,119×884 388×1,119×884 430×1,250×1,135
Fan Air Flow Rate m3/h 1,080 1,680 2,100 3,000 Dimension
Net Weight kg 38 40 46 52 61 69 69 95
External Static Pressure Pa 200 220 220 220
Air Flow Rate (Hi/Me/Lo) m3/h 200/200/150 300/300/210 400/400/230 500/500/400 650/650/550 800/800/650 1,000/1,000/700 1,250/1,250/800
Refrigerant Liquid Line mm Φ9.53 Φ9.53 Φ9.53 Φ12.7
Piping External Static
Diameter Gas Line mm Φ15.88 Φ19.05 Φ22.2 Φ25.4 (Hi/Me/Lo) Pa 100/70/40 120/90/50 120/90/50 120/90/50 130/100/90 130/100/90 165/120/60 100/50/30
Pressure
Condensate Drain VP25, outer diameter: Φ32mm Power Input (Hi/Me/Lo) W 120/110/75 165/155/120 210/200/130 330/310/230 2×(188/173/142) 2×(207/188/165) 2×(250/228/205) 2×(308/266/237)

Temperature range of fresh air drawn Cooling: 20ᵒC ~ 43ᵒC, Heating: -7ᵒC ~ 15ᵒC Current (Hi/Me/Lo) A 0.6/0.5/0.4 0.8/0.7/0.6 1.0/1.0/0.7 1.6/1.5/1.1 1.72/1.58/1.31 2.04/1.93/1.73 2.35/2.09/1.92 3.03/2.45/2.18
320×250
Connection Duct Diameter mm Ø144 Ø144 Ø144 Ø194 Ø242 Ø242 Ø242
+320×250
Model RPI-16.0KFNQL RPI-16.0KFNQH RPI-20.0KFNQL RPI-20.0KFNQH RPI-20.0KFNQLF RPI-20.0KFNQHF Approximate Packing Volume m3 0.37 0.37 0.43 0.49 0.94 1.15 1.15 1.25

Unit Power Supply AC 3Φ 380-415V/50Hz


KPI- KPI- KPI- KPI- KPF- KPF-
Nominal
Cooling kW 45.0 45.0 56.0 56.0 56.0 56.0
Model 150H-E-GQ 200H-E-GQ 250H-E-GQ 300H-E-GQ 400H-E-GQ 500H-E-GQ
Capacity
Heating kW 36.0 36.0 44.8 44.8 44.8 44.8 Unit Power Supply AC 3 Φ, 380 50Hz
Sound Pressure Level dB(A) 58 62 61 65 63 67 Summer % 63 63 63 63 63 63
Temp.
Outer Efficiency
(H×W×D) mm 635 × 1,950 ×805 635 × 1,950 ×805 735 × 1,950 ×805 735 × 1,950 ×805 735 × 1,950 ×805 735 × 1,950 ×805 Winter % 68 72 75 75 73 73
Dimensions
Net Weight kg 196 196 222 222 222 222 Summer % 57 57 55 56 55 53
Enthalpy
Refrigerant R410A Efficiency
Winter % 68 68 72 72 63 61

VENTILATION
Fan Air Flow Rate m3/h 4,000 4,000 5,000 5,000 6,000 6,000 Sound Pressure Level dB(A) 50 51 53 54 57 58

External Static Pressure Pa 200 300 200 300 200 300 Outer
(H×W×D) mm 536×1,500×1,300 536×1,500×1,400 640×1,700×1,500 640×1,750×1,600 1,655×1,400×850 1,730×1,700×850
Dimension
Refrigerant Liquid Line mm Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Net Weight kg 144 155 180 220 225 260
Piping
Diameter Gas Line mm Φ25.4 Φ25.4 Φ28.6 Φ28.6 Φ28.6 Φ28.6 Air Flow Rate m3/h 1,500 2,000 2,500 3,000 4,000 5,000
Condensate Drain RC1 (Internal Screw) External Static Pressure Pa 165 160 180 200 220 240
Temperature range of fresh air drawn Cooling: 20ᵒC ~ 43ᵒC, Heating: -7ᵒC ~ 15ᵒC Power Input W 2×440 2×810 2×925 2×1080 2×1,470 2×1,980
NOTE: Current A 2.84 3.08 4.19 5.23 5.57 7.51
1. Cooling capacity and heating capacity test in the following conditions:
Cooling conditions: 33°CDB, 28°CWB, pipeline length 7.5 metre, pipe height difference 0.0 metre 400×320 400×320 500×350 500×350 400×320 500×350
Connection Duct Diameter mm
+400×320 +400×320 +500×350 +500×350 +590×320 +700×320
Heating conditions: 0°CDB, -2.9°CWB, pipeline length 7.5 metre, pipe height difference 0.0 metre
( heating is the data without defrosting) Approximate Packing Volume m3 1.82 1.95 2.63 2.93 3.01 3.75
2. Noise test conditions are as follows:
At a distance of 1.5 metre from the unit surface. NOTE:
The above parameters are measured in the anechoic chamber without reflected echo, therefore the impact of the reflected echo Please confirm the model name for "wires remote controller" compatible with Total Heat Exchanger to your local distributor.
must be counted at the scene.
3. An air filter with dust removal efficiency of 50% or more needs to be installed at the air inlet.
4. When the field duct resistance is small and the fan speed is too high, the unit will appear the phenomena of abnormal shutdown,
fault, water spray etc., and the duct pipe should be insulated to prevent generating dew.
5. Air processor can only be used for processing fresh air, indoor air conditioning load processing need to use other air conditioners.
6. Refer to capacity restrains shown on Table below for indoor unit capacity connectable to outdoor unit.
Mixed System
System Only All Fresh Air Unit System
(All Fresh Air Unit and Other Indoor Unit)
Range of i) 80 to 100%
Combination 80 to 100% and
Capacity ii) Total Capacity of All Fresh Air: 30%

7. When outdoor temperature is below 20°C in cooling operation, the system will be automatically converted to ventilation operation.
When outdoor temperature is higher than 15°C in heating operation, it will be automatically converted to ventilation operation.
When lower than -7°C, the fresh air processing unit will stop running.

49

50
– –
OPTIONAL PARTS INTRODUCTION OF MOTION SENSOR KIT
(Each number (HP class) represents the number in the model nomenclature of each indoor units)

( kW = Cooling capacity)

CEILING CASSETTE
What is it? Image
4-way cassette type 4-way cassette compact type
It senses the amount of human activity,
Decoration Panel - (included as standard equipment) Decoration Panel P-AP56NAM undertakes automatic saving and achieves
Motion Sensor

Standard HR4A10NEWQ Receiver Kit PC-ALHC1


Receiver Kit intelligent energy saving.
Optional PC-ALH3 Motion Sensor SOR-NEC
Motion Sensor PS-MSK2 Duct Adapter PD-75C
Duct Adapter PD-75A

SET FREE Σ HNBQ series


2-way cassette type 1-way cassette type
0.8-3.0 (HP class) P-AP90DNA 0.8-1.0 (HP class) P-AP36CNA
Decoration panel
4.0-6.0 (HP class) P-AP160DNA Decoration Panel 1.5-2.0 (HP class) P-AP56CNA
Receiver kit PC-ALHD1 2.5-3.0 (HP class) P-AP80CNA
Motion Sensor SOR-NED Receiver Kit PC-ALHS1
Duct Adapter PD-150D Motion Sensor SOR-NES
Duct Adapter PD-100

Motion Sensor Kit


detecting area

DUCTED How does it work?


Perceives the amount of human activity and

OPTIONAL PARTS / INTRODUCTION OF MOTION SENSOR KIT


Standard PC-RLH11 undertakes automatic saving.
Receiver Kit
Optional PC-ALHZ1
0.8-2.5 (HP class) DUPI-131Q <example>
Drain-up 3.0-6.0 (HP class) DUPI-361Q
mechanism kit 8.0-10.0 (HP class) DUPI-15H2Q
Slim/Compact - (included as standard equipment)
Medium ESP/Low ESP 0.8-1.5 (HP class) KW-PP7Q
Medium ESP/Low ESP 1.8-2.5 (HP class) KW-PP8Q
High ESP/Low ESP 3.0-4.0 (HP class) KW-PP9Q
Air filter
High ESP/Low ESP 5.0-6.0 (HP class) KW-PP10Q
Compact 0.8-1.5 (HP class) KW-PP5Q
Compact 1.8-2.5 (HP class) KW-PP6Q

Standard operation for a room Moderate operation for a room More moderate operation if It is also possible to stop
OTHERS with a lot of human movement. with little human movement. people are absent for a certain the operation of the unit by
period. applying a particular setting if
Floor concealed type Ceiling/Floor convertible type people remain absent for more
Standard PC-RLH11 Standard PC-RLH11 than 30 minutes.
Receiver Kit Receiver Kit
Optional PC-ALHZ1 Optional PC-ALHZ1
Standard Receiver kit (PC-RLH11) is equipped with the unit in package as standard optional
part with Wireless Remote Controller (PC-LH3A).

Ceiling suspended type Wall mounted type MODEL


Motion Sensor Kit Indoor Unit Motion Sensor Kit Indoor Unit
Receiver kit PC-ALHP1 Standard PC-RLH11
Receiver kit
Motion Sensor SOR-NEP Optional PC-ALHZ1 PS-MSK2 4-way cassette type SOR-NES 1-way cassette type
1.5 (HP class) DUPC-63K1 0.8-2.3 (HP class) MSF-NP63A1
Strainer kit
Optional Drain Pump 2.0 (HP class) DUPC-71K1 2.5-4.0 (HP class) MSF-NP112A1 SOR-NEC 4-way cassette compact type SOR-NEP Ceiling Suspended type
2.5-6.0 (HP class) DUPC-160K1 (0.8-2.3HP class)
Standard Receiver kit (PC-RLH11) is equipped with the unit in package as standard optional
SOR-NED 2-way cassette type
part with Wireless Remote Controller (PC-LH3A).
(2.5-4.0HP class) 51
Receiver Kit is installed in the unit as standard part. Please use Receiver Kit (PC-ALHZ1)
when receiver kit needs to be installed separately from unit. Motion Sensor Kit is available only when advanced wired remote controller (PC-ARF1) is connected to each indoor unit. 52

Management
made simple

SET FREE Σ HNBQ series


MANAGEMENT MADE SIMPLE
We all like to have control over the indoor
spaces where we live, work and play.
That power is at your fingertips with a range
of controllers for every application. Simple
and intuitive interfaces, wireless mobility
and seamless connectivity make managing
even the most complex systems second
nature.

53

54

LINE UP OVERVIEW

COMPARING INDIVIDUAL CONTROLLERS COMPARING CENTRALIZED CONTROLLERS


WIRED REMOTE SIMPLIFIED WIRED ADVANCED WIRED ADVANCED WIRELESS WIRELESS REMOTE CENTRAL STATION CENTRAL STATION CENTRAL STATION CENTRALIZED
CONTROLLER REMOTE CONTROLLER REMOTE CONTROLLER REMOTE CONTROLLER CONTROLLER CENTRAL STATION
mini EZ EX ON / OFF CONTROLLER

HCWA10NEGQ PC-ARH1 PC-ARF1 HCRB10NEWQ PC-LH3A PSC-A32MN PSC-A64GT PSC-A128EX PSC-A64S PSC-A16RS
RCS Groups 1 1 1 - -

SET FREE Σ HNBQ series


RCS group 32 64 2560 (*1) 64 16
Connection Capacity
Indoor units (*1) 16 16 16 - -
Group 4 64 2048 (*1) 64 -
Temperature Setting Rate (*2) °C (0.5/1) °F (1) °C (0.5/1) °F (1) °C (0.5/1) °F (1) °C (0.5/1) °F (1) °C (1)
Capacity Block 2/4/8/16 4 512 (*2) 4 -
Indoor Fan Speed (*2) (*3) 3/4/6 taps 3/4/6 taps 3/4/6 taps 3/4/6 taps 3 taps Total Connection capacity
comparison Area - - 512 (*2) - -
Louver Direction (*2)
Individual Louver Setting (*2) - - - Indoor unit 160 160 2560 (*1) 160 160
Setting
Remote Control Primary-Secondary Setting - - -
Outdoor unit 64 64 1024 (*1) 64 -
Automatic Restart with Eco-operation - - - -
Function Building scale Small Medium Large Medium Medium
Automatic Reset Temperature (Cooling) - -
Selection
Temperature Indication (*4) - - - Operation Touch screen Touch screen Touch screen Button Button
Filter Sign - - - Operation panel size options 4 2 7 - -
Filter Sign Reset -
Display Layout - - - -
Louver Open / Close - - - -
List options - - 3 - -
Room Name Setting - - - -
Alarm Sign - - All together
Identifying indoor units side-by-side - - - By layout - - - -
Service & Screen Adjustment - - - -
By area - - - -
Installation Language - - - -
Screen Operation unit By block -
Temperature Unit - °C / °F (*5) -
Adjusting Brightness of Run Indicator - - - - By group - - - -
Sensor Condition Check - - - By RCS group -

LINE UP OVERVIEW
Model Display (*2) - - - -
Check Menu By indoor unit - - - -
Indoor / Outdoor PCB Check - - - -
Main 5 functions (*5) - (*6)
Alarm History Display - - -
Operation Lock / Set (*6) - - - Individual controller lock △ (*3) -
Lower Limit for Cooling Operation - - Control Function Filter sign reset -
Upper Limit for Heating Operation - -
Outdoor unit capacity control △ (*4) - - -
Built-in Timer (On / Off) -
Outdoor unit noise control - - - -
Adjusting Date / Time Setting - - -
Management Main 5 functions (*5) -
Automatic OFF timer setting - - -
Weekly Schedule - - - - Individual controller lock -
Settable Timer Operation Times (Per Day) - - 5 - - Alarm status & code - (*7)
Schedule
Holiday Setting - - - - Monitor Function
Filter sign -
Schedule On / Off - - - -
Power Saving with Motion Sensor - - - - Air inlet temperature of indoor unit - -

Outdoor Unit Peak cut control - - - - Air inlet temperature of outdoor unit - -
capacity control moderate control - - - -
Power Weekly - (*8) - (*8)
Saving Indoor Unit Address - - - -
Indoor Unit
Rotation Control Indoor Air Temperature difference Schedule Setting times per day 10 10 16 3 (*8) 3 (*8)
- - - -
Function Special day setting - - 5 - -
Automatic Fan Operation - - - -
ODU silent mode - - - - Annual/Summer/Winter schedule - - - -
Quick Function - - - - Alarm history (records number) 100 100 10000 - -
Comfort setting Control Cool Air - - - -
MENU External in/output history - - 1000 - -
Saving/ODU Noise Reduction Schedule - - - - Other function
Daylight Saving Time - - - - Management report visualization - -

Power Consumption visualization - - - - Data output by external media - - SD card, USB flash device - -

(*1) One external adapter can control [128 remote controller groups / 128 groups / 32 blocks],
(*1) All 16 indoor units need to be connected with transition wire. and Central Station EX can connect up to 15 adapters.
(*2) Availability depends on the indoor unit type connected to the each individual controllers. Please consult (*2) No restriction on the number of H-LINK
your distributors for more details. (*3) Individual Function Control in Each Remote Controller is not applicable
(*3) 6 taps is available for Ducted indoor unit, compact type, RPIZ-HNDTSQ only. (*4) Applicable by Schedule function or External Signal input
(*4) Indicated temperature can be selected from two options, the thermistor in the indoor unit or in the (*5) Main 5 functions mean 1) Run/Stop 2) Operation mode 3) Temperature setting 4) Fan speed 5) Louver control
individual controller. (*6) Only Run/Stop is available 55
(*5) Please contact your distributor in case temperature unit needs to be changed from °C to °F. (*7) Alarm Code cannot be displayed, but Operation indicator keeps flashing in red to inform abnormal condition
(*6) Only "bulk operation lock" available (*8) Available with 7-day timer (PSC-A1T) 56

WIRED REMOTE CONTROLLER HCWA10NEGQ

Temperature display
Room temperature
SPECIFICATIONS
Outer Dimensions (H×W×D)
Set temperature
(mm) 88.0×88.0×15.5
Liquid Crystal Display
(LCD) Screen FUNCTIONS
ON/OFF Button Run / Stop
Mode Button Up Button & Down Button Operation Mode
Auto Mode
Operation Mode Temperature Setting Rate _ 0.5°C/1°C/1°F
Setting
Temperature Unit _ °C/ °F
Cooling Mode Fan Speed _ 3/4/6 taps

SET FREE Σ HNBQ series


Louver Direction
Heating Mode Individual Louver Setting
Filter Sign
Dry Mode Filter Sign Reset
Fan Speed Setting Timer/Clock Setting Service
Alarm Sign
Fan Mode Alarm Sign History
Fan Speed Timer Setting
Daily Timer
Auto Mode Weekly Timer
(flickering) Timer On Schedule &
Management Main-sub Control
MAX Timer Off Operation Lock
Timer Valid for One Time Notes:
Timer Valid for One Day 1. Fan Speed Taps setting unit availability varies with the indoor
unit. Please check each technical catalog in advance.
Timer Set for a Week
2. Initial Setting of temperature display is "Set temperature"
display only. Please contact your dealer to display room
temperature.

MIN

INDIVIDUAL CONTROLLERS

SIMPLIFIED WIRED REMOTE CONTROLLER PC-ARH1

SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 120.0×70.0×17.0

FUNCTIONS
TEMP (Temperature Setting) Run / Stop
Run Indicator (Red)
Switch Operation Mode
ON / OFF Switch
Auto Mode Setting
Temperature Setting
Operation Mode Switch Swing Louver Setting
(Swing Louver Operation) Temperature setting rate_°C (0.5/1)_°F(1)
: FAN
: COOL Switch Back-light screen
: HEAT
: DRY Fan Speed_ 3/4/6 taps
: AUTO Louver Direction
By repeatedly pressing
Fan Speed Switch *Please contact your dealer in case “temperature setting rate”
the button, the setting
By repeatedly pressing the button, needs to be changed from °C to °F.
will change sequentially.
the fan speed setting will change sequentially.

57

58

ADVANCED WIRED REMOTE CONTROLLER PC-ARF1

Room Name Indicator


Swing Louver Indicator
Filter Sign Indicator Fltr
SPECIFICATIONS SIMPLE OPERATION
Operation Lock Indicator
Fan Speed Indicator
Schedule Timer Indicator Outer Dimensions (H×W×D)
Ventilation Indicator
(mm) 120.0×120.0×17.9 Directional Key Power-saving button
4 main items [Mode] [Speed] [Louver] [Temperature] Easy access to the any power-
saving functions, including
support-guidance.
Operation Mode
Indicator Setting
Temperature [Left] [Right]: [Up] [Down]:

SET FREE Σ HNBQ series


Indicator select one from 4 change the settings
main items in each item
Operation Guide
Indicator
Menu button
Display all setting except 4
Run Indicator Menu Switch
main items, like schedule.

Run / Stop Switch

Directional Key Enter Key Back/Help ECO


Switch Switch

EXAMPLE OF SYSTEM CONFIGURATION ADAPTABILITY

INDIVIDUAL CONTROLLERS
2 IDU Connection Up to 16 IDU Connection
Improved main-sub RCS control Thermometer function
By one main RCS, you can Current temperature can be
control the multiple IDUs displayed anytime, without
which are controlled by being in maintenance mode.
........
2 RCS sub RCS. *Thermometer can be chosen out of 3
control is ........ sensors (Air inlet, Air outlet, Remote
available * Operation Mode controller)
* Setting Temperature
Up to 16 IDU Main RCS Sub RCS Sub RCS Sub RCS

H-LINK
Primary RCS Secondary RCS Transition wiring is necessary Remote Control Cable Alarm code check Help Menu
Contact address shown in Access when in trouble.
the same display. Screen guide, Operation
Manuals, Troubleshooting
Q&A listed.
Run/Stop Filter Sign With Motion Sensor Kit
Operation Mode Filter Sign Reset
ODU Capacity Control
Auto Mode Setting Louver Open / Close • Peak Shaving Control
Service
Room Name Setting • Proper Limit Control
Temperature Setting
Fan Speed _ 3/4/6 taps Alarm Sign Power-Saving Indoor Unit Rotation Control ODU silent mode
Louver Direction Alarm History Display Automatic Fan Operation
Setting Screen Adjustment Set in the weekly schedule by
Individual Louver Setting Auto Recovery of Temperature
Screen Temperature Unit - °C /°F 5 times.
Remote Control Primary-Secondary Setting Upper Limit for Heating Operation
Automatic Restart with Adjusting Brightness of Run Indicator
Lower Limit for Cooling Operation
Eco-operation Operation Lock / Set
Function Weekly Schedule
Automatic Reset Temperature Main / Sub Control
Selection (Cooling/Heating) Settable Timer Operation Times (per day): 5
Management Built-in-Timer (on/off)
Temperature Indication Schedule Holiday Setting
Adjusting Date / Time Setting
Schedule On / Off 59
Thermometer Indication
ODU Noise Reduction Schedule
60
– –
ADVANCED WIRELESS REMOTE CONTROLLER HCRB10NEWQ RECEIVER KIT FOR WIRELESS REMOTE CONTROLLER

Transmitter SPECIFICATIONS HR4A10NEWQ PC-ALH3 PC-ALHC1 PC-ALHD1 PC-ALHS1 PC-ALHP1


(Standard) (Optional)
PC-RLH11
(Standard)
PC-ALHZ1
(Optional)
Outer Dimensions (H×W×D) (*1) (*1)

(mm) 140.0×55.0×16.8 Model


Transmitting Indication
LCD (Liquid Crystal Display) FUNCTIONS
Run / Stop 4-way cassette 4-way cassette 2-way cassette 1-way cassette Ceiling Ducted Floor Floor/ceiling Wall mounted
compact suspended concealed convertible
Mode Selection Switch Fan Speed Switch Operation Mode
Reset Switch On Switch Auto Mode Setting
Off Switch Setting Temperature Setting
Temperature Setting Rate _ °C (0.5/1)_°F(1) IDU type
Louver Angle Switch RCI-FSKDNQ RCIM-FSN4 RCD-FSN3 RCS-FSN RPC-FSN3 RPIH-HNAUNQ RPFI-FSNQ RPFC-FSNQ (*2) RPK-FSNQS (*2)
Fan Speed _ 3/4/6 taps RPIM-HNAUNQ RPK-FSN4M (*3)
Timer Switches RPIL-HNAUNQ

SET FREE Σ HNBQ series


Temp. Switch Louver Direction RPIZ-FSNQS/P
Filter Sign Reset Switch RPIZ-HNATNQ
Filter Sign Reset
RPIZ-HNDTSQ
Service Identifying indoor units side-by-side RPI-FSNQ
RPI-FSN3Q
Temperature Unit - °C / °F
HCRB10NEWQ
Schedule Built-in Timer (On / Off)

EXAMPLE OF SYSTEM Compatible


wireless
remote
CONFIGURATION
PC-LH3A
controller
— — — —
1 IDU connection

(*1) Fan speed = 3 taps available only when you use the standard receiver kit (PC-RLH11 or HR4A10NEWQ)
(*2) Concerning only [Floor/Ceiling Convertible type: RPFC-FSNQ] & [Wall Mounted Unit: RPK-FSNQS]Standard Receiver kit (PC-RLH11) is
equipped with the unit in package as standard optional part with Wireless Remote Controller (PC-LH3A)
(*3) Receiver Kit is installed in the unit as standard part. Please use Receiver Kit (PC-ALHZ1) when receiver kit needs to be installed
separately from unit.
H-LINK Notes
Remote Control Cable When you use standard receiver kit (PC-RLH11 or HR4A10NEWQ) equipped with wireless remote controller (PC-LH3A)
1) Setting Hi2 air flow rate is not available even if the connected indoor units has Hi2 air flow rate setting
2)It is not available to set up "remote control switch operation prohibited by each function setting" from central station (mini/EZ/EX)
3) It is not available to set up "remote control switch temperature setting range limitation function" from central station (mini/EZ/EX)

INDIVIDUAL CONTROLLERS

WIRELESS REMOTE CONTROLLER PC-LH3A

Transmitter
SPECIFICATIONS
Outer Dimensions (H×W×D)
Transmitting Indication (mm) 125.0×56.0×16.4

LCD (Liquid Crystal Display) FUNCTIONS


Run / Stop
Run/Stop Switch Fan Speed Switch Operation Mode
Auto Mode Setting
Reset Switch Louver Angle Switch
Setting Temperature Setting
Temp. Switch Temperature Setting Rate _ 1°C
Fan Speed _ 3 Taps
Louver Direction
Timer Switches
Identifying indoor units side-by-side
Service
Temperature Unit _ °C
Schedule Built-in Timer (On / Off)

 hen you use Standard Receiver kit equipped with PC-LH3A


W
(Wired Remote Controller), Centralized Controller cannot be
operated.

61

62

FOR SMALL-SCALE BUILDINGS
CENTRAL STATION mini PSC-A32MN

22 52.7
CAPACITY (5-inch) Touch Panel Operation Schedule
RC group 32 Easy to check the operation status using either of two monitoring Up to 10 actions/day per RCS
For example :
Group 32 screens (all groups or four pattern blocks [2/4/8/16]) group can be set as available as auto School
Block 4 Patterns (2/4/8/16) switch‑off timer
Indoor Unit 160
Outdoor Unit 64
Building Scale Small In case of classroom
120mm mini
in cooling mode

SPECIFICATIONS
9:00 ~ 10:00 27 °C Class: on
10:00 ~ 11:00 27 °C Class: on
Rated Power Supply 1-, AC 100-240V, 50/60Hz 11:00 ~ 12:00 - °C No class: off
Electrical Power Consumption 20W (Max.) 12:00 ~ 13:00 25 °C LUNCH TIME

SET FREE Σ HNBQ series


Communication Unit Units of Adopting for H-LINK 13:00 ~ 14:00 - °C No class: off
Lateral View (mm) Communication Line Non-polar 2-wire 14:00 ~ 15:00 27 °C Class: on
Communication Speed 9,600bps 15:00 ~ 16:00 - °C No class: off
140mm
Wiring Length 1,000m (Total Length) 16:00 ~ 17:00 27 °C Class: on
Display 5.0-inch Wide Color LCD (Full Dot) 17:00 ~ - °C No class: off
Display Control Touch Panel

FUNCTIONS
[Monitor (Block)]
• Run/Stop/Abnormality • Setting Temperature
• RCS Operation Prohibited Setting
Monitor Function • Accumulated Operating Time
Most compact in our touch panel centralized • Operation Mode • Setting Fan Speed
• Setting Louver • Filter Sign • Alarm Code"
controller. Its down-to-detail control • Run/Stop* • Fan Speed
functionalities, such as Weekly Scheduling, Control Function
• Operation Mode • Louver
• Temperature Setting RCS Group Function Control Accumulated Operation-Time Visualization
Accumulated Work Hours, etc., help you save • RCS Operation Prohibited
‑each operational item blocking‑prevent incorrect operation Support energy-saving management
• Filter Sign Reset
energy. Up to 32 remote-controlled groups and
*:“All Groups Run/Stop” command signal exception function for selected groups is
up to 160 indoor units can be connected to the available by “Exception of Run/Stop Operation.” function.
single air-conditioning system.

CENTRALIZED CONTROLLERS
RECOMMENDED FACILITIES

OFFICE SHOPS CULTURAL SMALL HOSPITAL SCHOOL


HERITAGE BUILDING

ON/OFF, "operation mode," "fan speed," "swing louver direction," "setting


temperature," and "prohibition of remote control operation for individual items
(run/stop, operation mode, fan speed, wind direction, setting temperature)"

EXAMPLE OF SYSTEM CONFIGURATION


Energy Saving
Outdoor unit power consumption control by schedule or external signals. Setting temperature range.
CS mini

Total 32
RCS Groups
H-LINK
Remote Control Cable

[Capacity Control of ODU] [Temperature Limitation for Each Remote Controller] 63

64

FOR MEDIUM-SCALE BUILDINGS
CENTRAL STATION EZ PSC-A64GT

25
80
55 CAPACITY (8.5-inch) Touch Panel Operation
RC group 64 A total of 64 remote controller groups (4 blocks)(64 outdoor units/160 indoor units) can be controlled
Group 64 Easy to check the operation status using either of two monitoring screens (all groups or blocks)
Block 4 Patterns
The panel for the block is bigger than for the CS MINI; you can check Mode, Fan Speed, Louver, Temperature, Inlet and Ambient Temperature.
Indoor Unit 160
Outdoor Unit 64
170mm Building Scale Small - Medium

SPECIFICATIONS
Rated Power Supply 1-, AC 100-240V, 50/60Hz
Electrical Power Consumption 30W (Max.)

SET FREE Σ HNBQ series


Communication Unit Units of Adopting for H-LINK
Lateral View (mm) Communication Line Non-polar 2-wire
250mm Communication Speed 9,600bps
Wiring Length 1,000m (Total Length)
Display 8.5-inch Wide Color LCD (Full Dot)
Display Control Touch Panel

FUNCTIONS
[Monitor 1 (all groups)] [Monitor 2 (block)]

• Run/Stop/Abnormality • Setting Temperature

Monitor Function
• RCS Operation Prohibited Setting
• Accumulated Operating Time ACCUMULATED OPERATION-TIME VISUALIZATION
Easy control with 8.5 inch color touch panel, • Operation Mode • Setting Fan Speed
• Setting Louver • Filter Sign • Alarm Code Supports Energy-Saving Management
Its down-to-detail control functionalities, • Run/Stop* • Fan Speed
such as Weekly Scheduling, Accumulated Work Hours, Control Function
• Operation Mode • Louver
• Temperature Setting
etc., help you save energy. Up to 64 remote-controlled • RCS Operation Prohibited
• Filter Sign Reset
groups and up to 160 indoor units can be connected *:“All Groups Run/Stop” command signal exception function for selected groups
to the single air-conditioning system. is available by “Exception of Run/Stop Operation.” function.

CENTRALIZED CONTROLLERS
RECOMMENDED FACILITIES

Alarm Information
Red color indication: immediate display of malfunction location and cause.
HOSPITAL OFFICE SMALL NURSING HOME HOTEL SCHOOL
BUILDING

EXAMPLE OF SYSTEM CONFIGURATION

CS EZ

Schedule
Up to 10 actions/day per RCS groups can be set as available as auto switch‑off timer.

Total 64
RCS Groups
H-LINK
Remote Control Cable

65

[Weekly Schedule] [Holiday Setting] 66



FOR LARGE-SCALE BUILDINGS
CENTRAL STATION EX PSC-A128EX

Flick and swipe to turn pages


32.5 27.8
CAPACITY EASY TO READ, EASY TO USE
H-LINK 16
Remote Controller group 2,560 (*1) The stand-alone Central Station EX uses a touch screen,
Group 2,048 (*1) capacitive LCD panel.
Block 512 (*2)
227.2mm Area 512 (*2)
Indoor unit 2,560 (*1)
Better display resolution (1,280x800)
Outdoor unit 1,024 (*1)
Building scale Large Larger screen (12.1 inches wide)
(*1) One external adapter can control [160 RC groups / 128 groups / 160 IDUs / 64
ODUs / Each layout], and Central Station EX can connect up to 15 adapters.
(*2) No restriction on the number of H-LINK

SET FREE Σ HNBQ series


372mm Lateral View (mm)
SPECIFICATIONS
Rated power supply 100~240VAC ± 10% (50/60Hz)
Electrical power consumption 50W (Max.)
SD Communication unit Units of Adopting for H-LINK
Communication line Nonpolar Two Wires
Communication speed 9,600bps
Energy Calculation Software* Wiring length 1,000m (Total Length)
Display 12.1 inch TFT color liquid crystal display
Extension Adapter PSC-AS01EXC
Display control Touch Panel
PSC-AD128EX *Required only for calculating electricity

For large scale buildings such as hotels, educational BETTER ENERGY SAVING AND QUICKER MANAGEMENT
facilities, or hospitals, our Central Station EX features
Management reports can be visualized in various ways, and data
a highly intuitive and functional 12.1-inch wide, wall-
mountable, colorful LCD screen. Control up to 2,560 can be acquired using SD memory and USB flash devices.
indoor units with our proprietary H-LINK system with
15 Extension Adapters (PSC-AD128EX) The following data can be displayed up
Various data such as operation time, to the previous two years:
settings, and log history can be

CENTRALIZED CONTROLLERS
saved to CSV files for better energy • Accumulated operation time (min.)
management and quicker service • Accumulated thermo-ON time (min.)
maintenance. • Average air intake temperature of
RECOMMENDED FACILITIES SD indoor unit
• Average air intake temperature of
outdoor unit
USB
• Average setting temperature
• Average RC sensor temperature
OFFICE HOSPITAL HOTEL SCHOOL
(It may not be available depending
on RC settings.)

FUNCTIONS
All together Each of the following setting is available in 3 Energy saving
Each area different [annual] [summer][winter] category • Run/Stop
Operation Drag to change the schedule
Each block => Weekly schedule • RC prohibition
unit
Each group => Up to 16 actions can be set per day • Temperature shift IMPROVED SCHEDULE SETTING Flick and swipe to see a different screen
Each RCS group => Exception day setting: 5 different types (For Cool/Dry mode: +1°C ~ +9°C (+1°F ~ +18°F))
=> Holiday setting (For Heat mode: -1°C ~ -9°C (-1°F ~ -18°F))
On/Off
• Mode shift
Three long-term category settings are now available: Annual,
Mode
Set temperature Schedule Setting items in schedule is as below; (Mode shifted to Fan when in Cool/Dry mode, Summer, and Winter.
Fan speed function • On/off and shifted to Stop in Heat mode)
Louver • Operation mode • Capacity control on outdoor units
Control • Setting temperature • Lower noise control for outdoor units
RC prohibition
function • Louver External input Touch and hold the memory axis to
Filter sign reset
Function selection for indoor units (*1) • Fan speed / output Control/Monitor add the memory to the schedule
Function selection for outdoor units (*2) • RC operation prohibition => Controlled items:
Capacity control for outdoor units (*2) • Capacity control for outdoor units • Run/Stop
Lower noise control for outdoor units (*2) • Lower noise control for outdoor units • Mode (Cool/Heat) Schedules can be color coded for
Alarm history: 10,000 records => Monitored items:
On/Off
• Run/Stop
easy confirmation
Mode History External In/Output history: 1,000 records
Pulse input history: 6 months • Mode (Cool/Heat)
Set temperature
• Alarm state
Air intake temperature Each of the following data of up to 2 years
RC sensor temperature (*3) can be shown: Touch the + button to see the
Others detailed schedule
Monitor Air intake temperature of outdoor unit • Accumulated operation time (min.)
function • Power consumption signal input
Fan Speed • Accumulated thermo-ON time (min.)
Management • Emergency stop
Louver • Average air intake temp temperature of
report
RC prohibition indoor unit (*1) Some indoor units may not fully support all functions.
visualization
Thermo-ON information • Average air intake temperature of outdoor (*2) It is available for applicable outdoor units only.
Filter sign/Auto cleaning fault unit (*3) There is a case that it cannot be shown in the screen, 67
Alarm status/Alarm codes • Average setting temperature
depending on the remote controller setting.
• Average RC sensor temperature 68

FOR LARGE-SCALE BUILDINGS
CENTRAL STATION EX PSC-A128EX

INTUITIVE INTERFACE FOR BETTER MONITORING


Three monitoring styles are available.

1. Panel style 3. List style


The panel color clearly shows the air conditioner operation mode. Setting/control information is shown in a list that can be filtered and sorted for
easy confirmation and comparison. In the list display, normal temperature and
One maximum-sized panel can show the following items with colors and icons
power consumption are provided so users can select formats according to their
for easy confirmation:
• Room name • Run/stop • Mode • Temperature • Fan speed • Louver desired items.
• Air intake temperature (RC sensor temperature or indoor temperature)
• Current status icon

SET FREE Σ HNBQ series


Maximum Minimum
size size

Largest range of sizes (seven)

2. Layout style
Upload your own layout images in multiple formats (BMP, JPEG,
PNG) and easily arrange indoor units by dragging them on the

CENTRALIZED CONTROLLERS
touch panel.
Normal mode Temperature mode Power consumption mode

Floor view

69

System diagram Actual room image 70


– –
FOR SMALL-MEDIUM-SCALE BUILDINGS
CENTRAL STATION PSC-A64S CENTRALIZED ON / OFF CONTROLLER PSC-A16RS

SPECIFICATIONS SPECIFICATIONS
Outer Dimensions (H×W×D) Outer Dimensions (H×W×D)
(mm) 120.0×120.0×70.5 (mm) 120.0×120.0×68.5

CAPACITY CAPACITY
120mm RC group 64 120mm RCS group 16
Group 64 Group 64
Block 4 Patterns Block -
Indoor Unit 160 Indoor Unit 160
Outdoor Unit 64 Outdoor Unit -

SET FREE Σ HNBQ series


FUNCTIONS FUNCTIONS
• Run/Stop/Abnormality • Setting Temperature • Run/Stop
Monitor Function
• RCS Operation Prohibited Setting • Alarm Notification
120mm Monitor Function • Accumulated Operating Time 120mm • Individual Run/Stop
• Operation Mode • Setting Fan Speed Control Function
• Simultaneous All Run/Stop
• Setting Louver • Filter Sign • Alarm Code
• Run/Stop* • Fan Speed
If your site has a dedicated building manager, the • Operation Mode • Louver · Only performs operation / stop control per remote
Control Function • Temperature Setting
Central Station PSC-A64S is suitable for providing • RCS Operation Prohibited control group.
• Filter Sign Reset
convenient monitoring of indoor climates. It controls
up to 160 indoor units and up to 8 sub-controllers *:“All Groups Run/Stop” command signal exception function for selected groups · By connecting to the H-LINK, up to 16 remote control
is available by “Exception of Run/Stop Operation.” function.
can be connected via H-LINK. In addition to setting groups and 160 indoor units can be controlled.
the operation mode and temperature, PSC-A64S also Up to 8 controllers can be connected to the H-LINK.
gives you advanced control over air quality and louver
orientation. Should a problem occur, a dedicated · An external input terminal is provided as standard.
alarm code helps you identify the issue. External signals enable the following functions:
central operation / stop, emergency stop, central
operation output, central alarm output.

· Can be used in combination with the central station.

CENTRALIZED CONTROLLERS
*Be sure to use it with a remote control switch. Indoor
units cannot be used without a remote control
switch.

*There are restrictions on remote group registration.


Please contact our sales staff for more information.

71

72

H-LINK
PO I N T
Flexible Wiring Routes

WHAT IS H-LINK? H-LINK is a "Hitachi" original communication system that can be used to control multiple outdoor (1) If indoor units are located
and indoor units from one control point. Its use assists installers and service engineers by simplifying in one place and the indoor
commissioning and service maintenance. For building owners and occupants, it provides outstanding unit to be controlled is in the
Point!
versatility enabling the connection of various types of central control options, enabling better system room where “Centralized
Controller” is installed
management. Our proprietary high-performance communication system enables the connection
 verall control is possible by
O
of control wiring between indoor and outdoor units, and between a centralized control system and connecting “Centralized Controller” to
indoor/outdoor units across two or more refrigerant systems. the indoor unit.
Delivery distance can be greatly

Basic Wiring reduced.

SET FREE Σ HNBQ series


PSC-A32MN

(2) If indoor units are located in


two places and any indoor units
of each system are located close
Point!
together
 verall control is possible by connecting
O
part of the indoor units of each system.
Delivery distance can be greatly reduced.
PSC-A32MN

ADVANTAGES 1. A multi air conditioner for a building and a package air conditioner for a store or office. It can be used
PSC-A32MN
with a home air conditioner.

2. There are no restrictions on the delivery route or order for wiring.

3. Just connect to a terminal block.


(An adapter and a dedicated connector are not necessary.) (3) If two systems are

H-LINK
completely separated
 verall control is possible by separately
O Point!
Point!
RECOMMENDED connecting the two systems to
“Centralized Controller.”
FACILITY (EXAMPLE) It is possible to select a wiring route based
on the wiring distance and the ease of
Educational institutions such  otels where it is preferable
H Rehabilitation facilities or installation.
as primary schools where to complete installation work hospitals where it is necessary
installation work cannot be during late evenings. to minimize the burden on
performed on weekdays. users.

PSC-A32MN

DEFINITION OF TERMS IN HITACHI CENTRALIZED CONTROL SYSTEMS


1. CS-Net / Central Station
Hitachi original central controller Outdoor unit (4) If indoor units are located
discretely
2. RCS Group (Remote Controller System Group)
 verall control is possible by connecting
O
Stands for a number of indoor units (up to 16 units) Point! Point! Point!
indoor units.
Indoor unit
connected using "same remote controller" wiring. Installation is possible through indoor
In this group, connected indoor units are all controlled wiring only without outdoor wiring.

in the same way.


3. Group
Stands for the multiple "RCS groups" that are
3. Group 2. RCS Group
registered in the central controller network setting.
CS-NET 3. Group PSC-A32MN
4. Block
Stands for the multiple "groups" that are registered in 4. Block 73

the central controller network setting. 74


– –
HC-A64BNP1 PSC-A1T
BMS ADAPTER for BACnet® Control up to 64 Indoor Units 7 DAY TIMER Scheduling Operation with PSC-A64S / PSC-A16RS

SPECIFICATIONS SPECIFICATIONS
Outer Dimensions (H×W×D) Outer Dimensions (H×W×D)
(mm) 68.0×240.0×154.0 (mm) 120.0×120.0×17.0

FUNCTIONS
Corresponding ANSI / ASHRAE Standard 135-2004
BACnet® Standard BACnet®
• Run Stop (Setting)
• Operation Mode (Setting)
EXAMPLE OF SYSTEM H-LINK
Remote Control Cable
Control Item at
Upper System
• Fan Speed Level (Setting)
• Indoor Temperature (Setting)
CONFIGURATION BACnet ® • Prohibiting RC Operation (Setting)
• Filter Sign Reset
• Run Stop (State)

SET FREE Σ HNBQ series


• Operation Mode (State)
• Fan Speed Level (State)
• Indoor Temperature (State)
· By using PSC-A1T with PSC-A64S or PSC-A16RS EXAMPLE OF SYSTEM CONFIGURATION
Field-supplied Monitoring Item • Prohibiting RC Operation (State) controllers, the air conditioners controlled by them
at Upper System • Filter Sign
Fire • Indoor Air Intake Temperature can be operated according to a schedule.
H-LINK
Lighting alarm Lift Ventilation • Alarm Signal
• Alarm Code Remote Control Cable
Centralized • Communication State · The timer can be set at 7-day intervals, and operation
Controller / stop can be set 3 times daily.

· Remote control can be prohibited in accordance with


the OFF time (when used with PSC-A64S and PSC-
A16RS).

· Two types of weekly schedule (A and B) can be set,


BACnet ®
and can easily be changed for summer and winter.
HC-A64BNP1
· The settings are all digitally displayed, allowing
operations and settings to be checked easily.

· The power failure backup function prevents the


timer from being stopped due to a power failure
– lasting up to 2 weeks. «PSC-A1T» «PSC-A64S»
HARC70-PE1
BMS ADAPTER for LONWORKS®

OTHERS
Bigger Connection Capacity (Up to 128 Indoor Units)

SPECIFICATIONS
Outer Dimensions (H×W×D)
(mm) 80.0×170.0×75.0

FUNCTIONS
Connection Connection by SNVT

EXAMPLE OF SYSTEM H-LINK


Remote Control Cable
Method to Upper
System
(Standard Network Variable Type)
to LONWORKS® Network

CONFIGURATION BACnet ® Quantity of


Connection
8 Remote Control Groups
(Max. 128 indoor Units)
• On / Off Order (nviOnOff_ng)
Control Item in
• Operation Mode Setting (nviMode_ng)
Upper System
• Temperature Setting (nviSetPoint_ng)
(ng: 0~7)
• All On / Off Order (nvi All OnOff)
Field-supplied
• On / Off State & Alarm (nvoOnOff_ng)
Monitoring Item • Operation Mode State (nvoMode_ng)
in Upper System • Temperature Setting (nvoSetPoint_ng)
Fire (ng: 0~7) • Individual Thermostat State
Lighting alarm Lift Ventilation (nvoThermo_ng)
·The number of maximum connectable refrigerant systems is
8 (0 to 7). The available setting range of refrigerant system
number and indoor unit addresses is 0 to 15.

LONWORKS®
75
HARC-70PE1 76

OUR HERITAGE

MAIN PRODUCTS
Air Compressor, Roller, PAC, Refrigerators, Compressor PAC, Refrigerators, VRF, PAC,
Casting Casting for REF, Casting Compressor Compressors

SET FREE Σ HNBQ series


VRF 1ST GENERATION

Hitachi’s first VRF “High-Multi” series
Contains multiple reciprocating compressors 5th overseas factory 1st Scroll Compressor 6th overseas factory
Individual indoor unit control available in the Philippines Factory in China in China

Indoor unit:
Indoor unit: Ceiling
Compressor for Floor-exposed
Cassette type
Refrigerators type (RPF)

VRF 5TH GENERATION


30HP
VRF 3RD GENERATION – VRF 7TH GENERATION
– Up to 12 indoor units 54HP
Japan’s 1st window- Up to 5 indoor units (130% in capacity) –
type air conditioner, PAC exported from World 1st IGBT Newly R407C adopted VRF “SET FREE Heat-pump/Heat-recovery
installed in a hotel Shimizuto UK for 1st training Indoor unit: Ceiling Outdoor unit: Inverter-driven VRF FSG”: heat-pump type “SET FREE FXG”: compatible Modular System VRF
in Kyoto the 1st time school established Suspended type (RPC) PAC controlled by Up to 115 Hz 1986 heat-recovery type “SET FREE FSXN”
micro-computer
built-in

OUR HERITAGE
1943

1951
1952

1956

1958

1961

1963

1965

1970
1971
1972
1973

1976

1978

1979

1981
1982
1983
1984

1986

1988

1990
1991

1996

1999

2003

2005

2011
2012

2016
Roller for mill
Indoor unit: Centrifugal VRF
1st air-cooled Unitary Point:“Outdoor unit”
Shimizu Factory Wall Mounted VRF 2ND GENERATION
PAC for export market Outdoor unit: that can be installed
Founded type (RPK) –
for low-ambient- 5HP 8HP & 10HP inside the building
Hitachi’s 1st Inverter-
temperature driven VRF With Scroll VRF 4TH GENERATION
market Compressor built-in 10 HP
Large casting; Hitachi’s 1st Packaged –
fan for tunnel AC (Water-cooled) Up to 8 indoor units (130% capacity)
(Floor Standing type) World 1st IGBT built-in Inverter
VRF leading to top-in-class
quietest operation
2nd Overseas Factory
founded in Brazil VRF 8TH GENERATION
Scroll Compressor
96HP
Production for

AC unit
Hitachi New Generation VRF