0% found this document useful (0 votes)
372 views2 pages

GSI312-1indicator User Manual

The document provides instructions for operating a GSI312-1 weighing batching controller. It describes the controller's input/output options including power supply, auxiliary power, communication interfaces, alarm settings. It also provides a diagram of controller connections for load cells and control outputs. The controller allows direct connection of 1-4 load cells and has up to 6 control outputs for processes like alarms and relays.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
372 views2 pages

GSI312-1indicator User Manual

The document provides instructions for operating a GSI312-1 weighing batching controller. It describes the controller's input/output options including power supply, auxiliary power, communication interfaces, alarm settings. It also provides a diagram of controller connections for load cells and control outputs. The controller allows direct connection of 1-4 load cells and has up to 6 control outputs for processes like alarms and relays.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

↓ SET

Code Illustration Operation process


Units selection (inactive)
312-1 □ - □□□□□□□ Input Signal: Blank: load cell
GSI312-1 Weighing Batching Controller
↓ SET


1:4-20mA 2:0-10V F:Others


Power ON
Instruction Manual Auxiliary Power:A: DC +12V /40mA Communication address :000-250
Self check
B: DC +24V/40mA C: DC 5V/80mA all LED on PV display
Baud rate:9.6k bit
Preset (AL1)value
Thanks a lot for selecting GALOCE product!
Communication interface:Blank:none ↓ SET
2: R232 4: R485 Parameter setting(press SET for 3 seconds to enter or quit) LCK=010,is for read only.
Before operating this instrument, please carefully read this manual and fully
↓ SET>3S LCK=000 means the parameter can be momodified.
AL3: R:relay S: SSR/LOGIC N:none
understand its contents. If any probroms, please contact our sales or distribu- Password selection,range:0-200
tors whom you buy from. This manual is subject to change without prior notice. AL2: R:relay S:SSR/LOGIC N:none Alarm 1 setting, range:0-999999
Connections (If any changed, refer the label on the meter).
AL1: R:relay S:SSR/LOGIC N:none ↓ SET
Application
Analog : Blank: none Alarm 1 mode setting,
AL3 0-10V AL2 AL1 Power24V
I : DC 4-20mA V: 0-10V H:High output L: Low output -
The instrument provides isolated aux. power.(regularly 5V/80mA) which al- -

1 7→
1 8→
+

+

lows1-4 loadcells connection directly. Up to 6 controll outputs are available for ↓ SET

20
21
19

22
23
13
14

16
Power Supply: Blank: 80-265V AC/DC

15

24
group ingredients weighing or fast/slow weighing;Data/Peak value holding E: 24V DC Alarm 2 setting, range:0-999999
function for choice.RS485 communication interface provides remote link with GSI312-1 Weighing Controller
PC/PLC.Besides,you can Start/Pause/Accumulate/Clear tare weight/average/ ↓ SET
Dimemsion: LH8: 6 digits display,48H*96W*80L mm EXC SG
clear zero,etc. for the displaying weight with external control terminal. Alarm 2 mode setting,

10
11
→7

12
1

→8
3

→5

9
2

→6
4
H: High output L: Low output
Parameters setting
Code Illustration ↓ SET EXC+ EXC- SG- SG+
Alarm hysteresis value setting(for AL1,AL2), RST
①↑ 1.Parameter setting: In displaying estate,
Range:0-999999 Application examples
a.press and hold SET key>3s, enter / quit parameters setting menu.
OUT1
b. Press <</Rst key, LED flashes, ↓ SET 1、 LH8-IRRC wiring
PV
OUT2
BT/SV2
←③ c.Press Up / Down key to modify, Alarm 3 setting, OUT 4-20mA

1 6→
1 5→

+
d. Press SET key to confirm. (not available if no AL3)

20
17
18
19
11

13
14
12
←⑥ ↓ SET
<<

e. Press SET key again to read the following parameters one by one.
②→SV SET <</Rst Alarm 3 mode setting, range:0-999999
2.Adjustment:
<<

LOADCELL
a. well connected wires and sensor,turn the power on, H: High output L: Low output(not available if no AL3)
↑ ↑ ↑ b.Parameter 5EL setting. press UP and DOWN key >3s to enter the menu ↓ SET
④ ⑤ ⑦

10
7
→1

→ 8
3

5
→2

→9
4
① Measuring value/Parameter code display set the data in hundredth bit to 0. press SET key to confirm. Alarm hysteresis value setting(for AL3),



+
② Parameter value/ preset value

+
b. Set USP=Standard weight(suggest more than 20% load cell scale) range:0-999999(not available if no AL3) 80- 260V GND SG
set PVF= 0000. AL1 AL2 5V
③ Control output indicate lamps: On: active, Off: inactive ↓ SET AC/DC
c.Without any weight on the instument,press DOWN key >5s until OK Marterial loss compensation value setting,
OUT1: Alarm 1, OUT2: Alarm 2, BT/SV2: Alarm 3 2、LH8E-IRNB with 6-wire input
flashes. That’s to set the zero point and it displays 0.0;
④ Parameters Select / Confirm key PV(display value)=actual value+PVF 4-20mA
d. Add the weight equal to setted USP,press UP key>5s until OK flashes. -

1 6→
1 5→

+
⑤ Shift key / tare weight Clear key ↓ SET

20
That’s to set the high value.and it displays the added weight.

17
18
19
11

13
14
12
⑥⑦ UP & DOWN key e. Should big error happens,just repeat the above operation. Reference weighing for calibration/
Input Regular: mV(Load cell) Customized:mA/V
f. After finish the above operation, press<</Rst key >2 s. to clear tare weight. Loadcell scale, range:0~999999
Specifications g. Parameter 5EL setting. press UP and DOWN key >3s to enter the menu
↓ SET
set the data in hundredth bit to 1. press SET key to confirm.

10
→7
→1

8
3

5
→2

9
4
Power 90-260V AC/DC OR 15-30V AC/DC Decimal point setting for PV value:
3: Clear tare weight :in display estate, press <</Rst or external RST more


+→



- -
0000 000.0 00.00 0.000 -

+
Power Consump. ≤ 5VA than 2 seconds to clear, then it displays 0; 24V DC SENSE SG EXC
Accuracy 0.1%F.SˇŔ2digit (24 bit A/D convertion) 4.The instrument will return to the measuring estate without any operation ↓ SET Response for 4mA/0V output low value
AL1

Sampling speed 16-128 times/sec for 25 seconds. 3、 LH8E-RRR4C wiring


setting,range:0-999999
5.when accumulated/average function is needed,the accumulate value will (not available if no analog output) AL3 AL2 AL1
Relay Open contact 250V AC 3A or 30V DC 3A COS¢=1 Power24V
be in the Low LED. Press external terminal RST to reset,SUM to add up ↓ SET -



+
Input Regular:mV(loadcell), Customize:mA/V Response for 20mA/10V output high value
the value will be added when each operation to SUM .

20
21
19

22
23
13

17
14

16

18
15

24
Analog Output 0-10V / 4-20mA output,configurable by software setting,range:0-999999
6.Decimal point setting for parameter AL1,AL2,AL3,HY1,HY2,PVF,USP
Auxiliary Power Isolated DC 24V/12V/Max 40mA, or 5V/80mA (not available if no analog output)
tRL,rRH: press <</Rst key,LED flashes,then one hand to hold SET key,
and the other hand to press UP key to shift the decimal point.Press SET
↓ SET Digital filter constant, 0: direct display
Communication RS232 or RS485 MODBUS RTU protocol RS485 EXC SG
key again to confirm and save. 1: mean value of 2 sampling display,

10
11
12
→7
Mounting dimemsions: 91+0.5X45+0.5mm

→8
→3

→ 5

9
2

→6
4
2: mean value of 4 sampling display


B- A+ EXC+ EXC- SG- SG+
RST
On displaying estate,press UP and DOWN key for more than 3 seconds to access to parameter SEL setting.The operation steps are
the same as the other settings. After setting, press UP and DOWN key to quit.
This operation is to modify SEL value ONLY..Other parameters are fixed by manufactor.Please do not make any changement.

If SEL=XXX1XX,
that means the user canˇŻt do on-site weight adjustment by pressing UP/DOWN key.
↓ If SEL=XXX0XX,
that means the user can do on-site weight adjustment by pressing UP/DOWN key.
Note:
×××.×
*** X means the original data. Do not make modification.
***Just make modification to data 1/0
***Factory setting is XXX0XX. After on-site adjustment,make sure SEL=XXX1XX.This is to avoide incorrect display by userˇŻs inapropriate key-pressing operation.

SET
↓ Zero point adjustment for current/volt output,4mA/
Adjustment for large-tonnage scale loadcell:
0.1V adjustable. Available when have analog A. Set USP=the total weight of all input loadcells(eg. each loacell is 1000KG, 3 loadcells in total, the total
×××.× output.Factory setting,do not make modification.
weight is 3000kg.Then set USP=3000.).
↓SET Full point adjustment for current/volt output,20mA/ Set PVF=0.000,
10V adjustable. Available when have analog
×××.× output.Factory setting,do not make modification. B. Record the displaying value(PV1) when no weight on the loadcells(eg.100.5kg).
↓SET A/D convert data when no weight
C. Add the standard weight(the weight should be larger than 20% of the total loadcell weight,eg.500kg).
on the loadcell,that is the factory Recorder the displaying value(PV2)(eg. 630kg).
setting for zero point.
D. Calculation: The actual weight added(eg. 500kg)/(PV2-PV1)
↓SET eg.500/(630-100.5)=0.9442.
A/D convert data when some
weights on the loadcell,that is the E. Calculation: USP*(The actual weight added/(PV2-PV1)).
factory setting for full point.
eg. USP*(500/529.5)=2832.86,
Note: All the above parameters are for factory setting.Do not make any adjustmnet.
Then set USP=2832.86 again.
F. The adjsutment is finished.