FTD00917 - TT01-TT03 PCR3 - CODDE - v14 - ENVPEP2012004 - V1

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

ENVPEP2012004_V1 - Product Environmental Profile - Resi9 Combi SPU 1PN C Surge Protection Device

Product Environmental Profile


Resi9 Combi SPU 1PN C Surge Protection Device

ENVPEP2012004_V1 # Internal 2/2022


ENVPEP2012004_V1 - Product Environmental Profile - Resi9 Combi SPU 1PN C Surge Protection Device

General information

Representative product Resi9 Combi SPU 1PN C Surge Protection Device - R9L20625

The function of Resi9 Combi SPU 1PN C Surge Protection Device is to provide in low voltage
power systems:
--SPU (Surge transient overvoltages and Power frequency overvoltage protection Unit):

Protect during against direct or indirect effects of lightning or against transient overvoltages
Description of the product electrical equipements connected to electrical networks

Detect power frequency overvoltage and trigger MCB and indicate overvoltage fault
--MCB (Miniature Circuit Breaker):

Protect the installation against overloads and short-circuits in circuit (with assigned voltage 400
VAC (Ue) and rated current 25A (In)).

The function of the product is to provide for 20 years in low voltage power system with operational
voltage Ue = 400 VAC and rated current In=25A.
This protection is ensured in accordance with the following parameters:
- Number of poles 1P+N
- Rated breaking capacity 6kA
Functional unit - Tripping curve C Type
Resi9 Combi SPU 1PN C Surge Protection Device withstands the following:
- IEC 61643-11:2011
- IEC 63052:2019
- BS EN 50550:2011+A1:2014
- IEC 60898-1:2016

Constituent materials

Reference product mass 375 g including the product, its packaging and additional elements and accessories

PBT Polybutylene PPS Polyphenylene sulfure -


Terephtalate - 1.9% 1.6%
PET Polyethilene
Terephtalate - 1.4%
PC Polycarbonate - 2.4%

PA Polyamide - 19.1%

Miscellaneous - 0.4%
Steel - 49.9%

Various - 0.4%

Electronic components -
19.1%

Cardboard - 6.7%

Aluminium - 0.4%
Copper - 5.6%
Zamak - 0.9%
Brass - 1.1% Stainless steel - 1.5% Ferrous alloys - 2.9%

Plastics 26.3%
Metals 62.2%
Others 26.5%

ENVPEP2012004_V1 # Internal 2/2022


ENVPEP2012004_V1 - Product Environmental Profile - Resi9 Combi SPU 1PN C Surge Protection Device

Substance assessment
Products of this range are designed in conformity with the requirements of the RoHS directive (European Directive 2011/65/EU of 2
January 2013, amended in March 2015, 2015/863/EU and in November 2017, 2017/2102/EU) and do not contain, or only contain in the
authorised proportions, lead, mercury, cadmium, hexavalent chromium or flame retardants (polybrominated biphenyls - PBB,
polybrominated diphenyl ethers – PBDE), Bis (2-ethylhexyl)phthalate - DEHP, Benzyl butyl phthalate– BBP, Dibutyl phthalate - DBP,
Diisobutyl phthalate - DIBP) as mentioned in the Directive.
Details of ROHS and REACH substances information are available on the Schneider-Electric Green Premium website
http://www2.schneider-electric.com/sites/corporate/en/products-services/green-premium/green-premium.page

Additional environmental information

The Resi9 Combi SPU 1PN C Surge Protection Device presents the following relevent environmental aspects
Manufacturing Manufactured at a Schneider Electric production site ISO14001 certified
Weight and volume of the packaging optimized, based on the European Union's packaging directive
Distribution
Packaging weight is 26.5 g, consisting of cardboard (99.92%), paper (0.08%)
The product does not require special installation procedure and requires little to no energy to install. The disposal of
Installation
the packaging materials are accounted for during the installation phase (including transport to disposal).
Use The product does not require special maintenance operations.

End of life optimized to decrease the amount of waste and allow recovery of the product components and materials

This product contains electronic card (14.735g) that should be separated from the stream of waste so as to optimize
end-of-life treatment.

End of life The location of these components and other recommendations are given in the End of Life Instruction document
which is available on the Schneider-Electric Green Premium website
http://www2.schneider-electric.com/sites/corporate/en/products-services/green-premium/green-premium.page
Based on “ECO’DEEE recyclability and recoverability calculation method”
Recyclability potential: 63% (version V1, 20 Sep. 2008 presented to the French Agency for Environment
and Energy Management: ADEME).

Environmental impacts

Reference life time 20 years(According to PSR0005)


Product category Combination of functions

The product does not require special installation procedure and requires little to no energy to install. The
Installation elements disposal of the packaging materials are accounted for during the installation phase (including transport to
disposal).

SPU:Product power consumption is 1.98 W at 100% Load rate and Load factor : 100% of In,Use rate: 100%
of the RLT.
Use scenario
MCB:Product power consumption is 3.55 W at 100% Load rate and 0.8875 W at Load factor : 50% of In,Use
rate: 30% of the RLT.

Geographical
Spain
representativeness

Technological
All the technologies pertaining to product manufacturing are represented in manufacturing phase properly.
representativeness
Manufacturing Installation Use End of life
Electricity grid mix;
Energy model used Electricity grid mix; AC; Electricity grid mix; AC;
AC; consumption mix,
Energy model used: China consumption mix, at consumption mix, at
at consumer; 230V;
consumer; 230V; ES consumer; 230V; ES
ES

ENVPEP2012004_V1 # Internal 2/2022


ENVPEP2012004_V1 - Product Environmental Profile - Resi9 Combi SPU 1PN C Surge Protection Device

Compulsory indicators Resi9 Combi SPU 1PN C Surge Protection Device - R9L20625

Impact indicators Unit Total Manufacturing Distribution Installation Use End of Life
Contribution to mineral resources depletion kg Sb eq 7.60E-04 7.47E-04 0* 0* 1.29E-05 0*
Contribution to the soil and water acidification kg SO2 eq 8.82E-01 1.43E-02 2.94E-04 0* 8.67E-01 1.54E-04
Contribution to water eutrophication kg PO43- eq 5.79E-02 3.58E-03 6.77E-05 0* 5.42E-02 4.56E-05
Contribution to global warming kg CO2 eq 1.81E+02 4.97E+00 6.44E-02 0* 1.76E+02 9.41E-02
kg CFC11
Contribution to ozone layer depletion 6.56E-06 5.82E-07 0* 0* 5.98E-06 4.06E-09
eq
Contribution to photochemical oxidation kg C2H4 eq 5.29E-02 1.36E-03 2.10E-05 0* 5.15E-02 1.57E-05
Resources use Unit Total Manufacturing Distribution Installation Use End of Life
Net use of freshwater m3 6.38E+01 3.41E-02 0* 0* 6.38E+01 0*
Total Primary Energy MJ 3.80E+03 7.17E+01 9.10E-01 0* 3.73E+03 7.42E-01

100%

90%

80%

70%

60%

50%

40%

30%

20%

10%

0%
Contribution to Contribution to Contribution to Contribution to Contribution to Contribution to Net use of Total Primary
mineral the soil and water water global warming ozone layer photochemical freshwater Energy
resources acidification eutrophication depletion oxidation
depletion

Manufacturing Distribution Installation Use End of life

ENVPEP2012004_V1 # Internal 2/2022


ENVPEP2012004_V1 - Product Environmental Profile - Resi9 Combi SPU 1PN C Surge Protection Device

Optional indicators Resi9 Combi SPU 1PN C Surge Protection Device - R9L20625
Impact indicators Unit Total Manufacturing Distribution Installation Use End of Life
Contribution to fossil resources depletion MJ 2.29E+03 5.02E+01 9.04E-01 0* 2.24E+03 5.97E-01
Contribution to air pollution m³ 6.98E+03 9.62E+02 2.74E+00 0* 6.01E+03 5.33E+00
Contribution to water pollution m³ 5.14E+03 9.38E+02 1.06E+01 0* 4.18E+03 6.84E+00
Resources use Unit Total Manufacturing Distribution Installation Use End of Life
Use of secondary material kg 3.98E-02 3.98E-02 0* 0* 0* 0*
Total use of renewable primary energy resources MJ 6.97E+02 9.60E-01 0* 0* 6.96E+02 0*

Total use of non-renewable primary energy resources MJ 3.11E+03 7.08E+01 9.09E-01 0* 3.03E+03 7.41E-01

Use of renewable primary energy excluding renewable


MJ 6.97E+02 8.55E-01 0* 0* 6.96E+02 0*
primary energy used as raw material
Use of renewable primary energy resources used as
MJ 1.05E-01 1.05E-01 0* 0* 0* 0*
raw material

Use of non renewable primary energy excluding non


MJ 3.10E+03 6.70E+01 9.09E-01 0* 3.03E+03 7.41E-01
renewable primary energy used as raw material

Use of non renewable primary energy resources used


MJ 3.72E+00 3.72E+00 0* 0* 0* 0*
as raw material
Use of non renewable secondary fuels MJ 0.00E+00 0* 0* 0* 0* 0*
Use of renewable secondary fuels MJ 0.00E+00 0* 0* 0* 0* 0*
Waste categories Unit Total Manufacturing Distribution Installation Use End of Life
Hazardous waste disposed kg 3.40E+01 3.31E+01 0* 0* 2.56E-01 6.89E-01
Non hazardous waste disposed kg 2.48E+02 2.50E+00 0* 0* 2.45E+02 0*
Radioactive waste disposed kg 3.29E-01 1.09E-03 0* 0* 3.28E-01 0*
Other environmental information Unit Total Manufacturing Distribution Installation Use End of Life
Materials for recycling kg 3.94E-01 4.98E-02 0* 3.51E-02 0* 3.09E-01
Components for reuse kg 0.00E+00 0* 0* 0* 0* 0*
Materials for energy recovery kg 1.53E-02 0* 0* 0* 0* 1.53E-02
Exported Energy MJ 1.11E-04 1.05E-05 0* 1.01E-04 0* 0*
* represents less than 0.01% of the total life cycle of the reference flow
Life cycle assessment performed with EIME version EIME v5.9.1, database version 2016-11 in compliance with ISO14044.

The use phase is the life cycle phase which has the greatest impact on the Acidification potential of soil and water,Eutrophication,Global
warming,Ozone layer depletion ODP steady state,Photochemical oxidation(high NOx),Net use of freshwater,Total Primary Energy.
The manufacturing phase is the life cycle phase which has the greatest impact on the Abiotic depletion(elements,ultimate reserves).
Please note that the values given above are only valid within the context specified and cannot be used directly to draw up the
environmental assessment of an installation.

Registration number ENVPEP2012004_V1 Drafting rules PCR-ed3-EN-2015 04 02

Date of issue 2/2022 Supplemented by PSR-0005-ed2-EN-2016 03 29

Information and reference


Validity period 5 years www.pep-ecopassport.org
documents
Independent verification of the declaration and data
Internal X External
The elements of the present PEP cannot be compared with elements from another program.
Document in compliance with ISO 14021:2016 « Environmental labels and declarations - Self-declared environmental claims (Type II
environmental labelling) »

ENVPEP2012004_V1 # Internal 2/2022


ENVPEP2012004_V1 - Product Environmental Profile - Resi9 Combi SPU 1PN C Surge Protection Device

Schneider Electric Industries SAS


Country Customer Care Center
http://www.schneider-electric.com/contact

35, rue Joseph Monier

CS 30323
F- 92506 Rueil Malmaison Cedex
RCS Nanterre 954 503 439
Capital social 896 313 776 €
www.schneider-electric.com Published by Schneider Electric
ENVPEP2012004_V1 © 2019 - Schneider Electric – All rights reserved 2/2022

ENVPEP2012004_V1 # Internal 2/2022