WIZ1000 User's Manual: (Version1.0)
WIZ1000 User's Manual: (Version1.0)
(Version1.0)
CLICK
Copyright Notice
WARNING : This equipment has been tested for a Class A digital device.
1. INTRODUCTION......................................................................................... 7
2. WIZ1000 ................................................................................................ 10
8. WARRANTY............................................................................................. 38
Tables
Table 1. Specification............................................................................. 8
Table 2. Products Contents...................................................................... 9
Table 3. Serial Configuration Frame Format ................................................. 25
Table 4. Serial Configuration Reply Frame Format ......................................... 25
Table 5. Serial Configuration STX & ETX .................................................... 25
Table 6. Serial Configuration Reply Code .................................................... 25
Table 7. Serial Configuration Command Code .............................................. 27
Table 8. Serial Configuration Testing Process ............................................... 29
Table 9 Telnet Com Port Options List ......................................................... 32
Table 10. Testing Environment of WIZ1000 .................................................. 34
Table 11. RS-232 PIN Assignment ............................................................ 37
- RoHS Compliant
ITEM Description
8051 compliant
MCU
(having internal 62K Flash, 16K SRAM, 2K EEPROM)
TCP/IP W5100 (Ethernet MAC & PHY Embedded)
Protocol TCP, UDP, IP, ARP, ICMP, MAC, DHCP, PPPoE, DNS
Network Interface 10/100 Mbps(Auto detection), RJ-45 Connector
Serial Interface RS232(DB9)
Serial Signal TXD, RXD, RTS, CTS, GND
Parity : None, Even, Odd
Data Bits : 7,8
Serial Parameters
Flow Control : None, RTS/CTS, XON/XOFF
Speed : up to 230Kbps
Input Voltage DC 5V
Power Consumption Under 200mA
Temperature 0°C ~ 80°C (Operation), -40°C ~ 85°C (Storage)
Humidity 10 ~ 90%
Table 1. Specification of WIZ1000
WIZ1000 is a protocol converter that transmits the data sent by serial equipment to Ethernet
and converts back the TCP/IP data received through the network into serial data to transmit
back to the equipment. When the data is received from serial port, it is sent to W5100 by
MCU. If any data is transmitted from Ethernet, it is received to the internal buffer of W5100,
and sent to the serial port by MCU. MCU in the module controls the data according to the
configuration value that user defined.
ⓐ ⓑ
ⓒ ⓔ
ⓕ
ⓖ
ⓙ
ⓚ
ⓝ ⓞ ⓟ ⓠ
ⓜ
ⓑ Enable Serial Debug Mode : If this mode is checked, you can monitor the status and
socket message of WIZ1000 (listen OK, connect fail etc.) through serial terminal. If Debug
mode is on, debug message can cause abnormal operation of the serial device. Therefore,
just use this mode only for Debug mode.
ⓒ Board List : If you click “Search” button, all the MAC addresses on a same subnet, will be
ⓓ IP Configuration Method: Select IP setting mode, you can select one from Static, DHCP,
PPPoE mode.
Static: “Static” is the option for setting WIZ1000 with static IP address. First select MAC
address that you want to set it as static IP in ‘board list’. Then, the “Local IP, Subnet,
Gateway boxes are enabled. Input Static IP address and click “setting” button. Then IP is set
as you want. (PPPoE ID, Password box will be disabled)
DHCP: Set this option to use DHCP mode. First, check ‘DHCP’ and click ‘Setting’ button. If IP
address is successfully acquired from DHCP server, the MAC address will be displayed on the
board list. (It takes some time to acquire IP address from DHCP server)
When a module on the board list is selected, IP address, Subnet mask and Gateway are
displayed. If module could not acquire network information from DHCP server, IP address,
Gateway Address and Subnet mask will be initialized to 0.0.0.0.
PPPoE : WIZ1000 supports PPPoE for ADSL user. When you select PPPoE in “IP Configuration
Method” PPPoE ID and Password box will be enabled.
1. To set PPPoE, connect PC to WIZ1000 directly and execute Configuration Tool program on
PC. (Configuration Tool version should be 2.1 or above)
2. Select ‘PPPoE’ of the “IP Configuration Method” tab and input ID & Password.
3. Click “setting” button to apply.
4. Connect Module to ADSL Line.
5. If “Enable Serial Debug Mode” is selected, you can see PPPoE access status
via Serial console.
ⓗ PPPoE ID/Password : If you select ‘PPPoE’ mode, input ID/Password which you received
from ISP company.
ⓘ Server IP/Port : When WIZ1000 is set as “Client mode” or Mixed mode”, server IP and port
should be set. WIZ1000 attempts to connect this IP address.
ⓙ Network mode :
client/server/mixed : This is to select the communication method based on TCP. TCP is the
protocol to establish the connection before data communication, but UDP just processes the
data communication without connection establishment.
The Network mode of WIZ1000 can be divided into TCP Server, TCP Client and Mixed mode
according to the connection establishing method. At the TCP server mode, WIZ1000
operates as server on the process of connection, and waits for the connection trial from the
client. WIZ1000 operates as client at the TCP Client mode on the process of connection, and
tries to connect to the server’s IP and Port. Mixed modes supports both of Server and Client.
The communication process of each mode is as below.
At the TCP Server mode, WIZ1000 waits for the connection requests.
In order to operate this mode, Local IP, Subnet, Gateway Address and Local Port Number
should be configured first.
As illustrated in the above figure, data transmission proceeds as follows,
1. The host connects to the WIZ1000 which is configured as TCP Server mode.
2. As the connection is established, data can be transmitted in both directions – from the host
to the WIZ1000, and from the WIZ1000 to the host
In TCP Client mode, WIZ1000 can actively establish a TCP connection to a host computer
when power is supplied.
As like TCP Server mode, the Mixed mode is useful for the case that the monitoring center
tries to connect to the serial device (in which WIZ1000 is used) to check device status. In
addition to this, if any emergency occurs in the serial device, the module will change to
Client mode to establish the connection to the server and deliver the emergency status of the
device.
ⓚ UDP
As we know, UDP is not a connection oriented protocol. But the communication port should
also be defined well. If the UDP mode is selected, the data from serial interface can be
defined where to delivery via the “Sever IP Address” and “Port”, and the WIZ1000 can also be
defined where to receive Ethernet data from via the “Remote Peer IP Address” definition. If
the data destination and source are the same, the two IP address will also be the same.
Please note the destination and source are using the same port.
ⓛ Use DNS : If DNS function is needed, check this option and input the domain name of DNS
server. DNS(Domain Name System) is the database system having information about IP address
and corresponding domain name. When connecting to domain name, you can use DNS function
of WIZ1000. Input IP address of DNS server provided by ISP in DNS Server IP, and domain name
in the Server (Domain)
If server has dynamic IP address, but domain name, if you use DNS function, you do not need
to configure server IP address whenever it’s changed.
☞ If module does not have valid network information, Direct IP search is not available.
ⓝ Search
This function is used for searching the connected WIZ1000s in the same sub-network. If you
want to configure or update the firmware of your WIZ1000, you have to find your WIZ1000 at
first. In order to protect WIZ1000 from attacking, a search password is needed to input in the
popup dialog after “Search” button clicked as shown in Figure 7. The password can be
modified by using this configuration tool and its maximum length is 8 bytes. Be sure to input
the correct password of your WIZ1000, otherwise, your device cannot be found. After
searching over, the MAC addresses of found WIZ1000s are listed in the “Board list”. The
default password is ‘wiznet’.
ⓞ Setting
This function is to complete the configuration change.
If you select the MAC address from the “Board list”, the default configuration value of the
module will be displayed. Change the configuration and click “Setting” button to complete
the configuration. The module will re-initialize with the changed configuration. Changed
value is saved in the EEPROM of the module. Thus, the value is not removed even though
power is disconnected.
The configuration value can be changed in below steps.
ⓟ Upload
Firmware will be uploaded through network
☞ After uploading the firmware, 20~30 seconds are required for initialization.
ⓠ Exit :
Close the configuration tool program.
Time: If there is not any new data during designated time, all data in the serial buffer is
converted to Ethernet packet. If new data is received, the time is re-calculated and the
received data is saved in the serial buffer. Time condition can be utilized when the
serial data size is variable and has no ending character, but needs to be delivered in
frame unit. (If the value is ‘0’, option is not used)
Size: When data is collected as much as the defined size in the serial buffer, it is transmitted
to Ethernet (If the value is ‘0’, option is not used)
Character: The data is collected in the serial buffer until specified character is received, and
transmitted to Ethernet. The character can be specified in Hex formation. (The value is
‘0’, this option is not used)
Any one of three conditions is satisfied, the data is transmitted to the Ethernet.
Ex) Delimiter: Size=10, Char=0x0D
Serial data: 0123456789abc
Ethernet data: 0123456789
☞ “abc” will be remained in the serial buffer of module.
ⓣInactivity timer
After the connection is established, if there is not data transmission within the time defined
in Inactivity time, the connection is closed automatically.
The default value is ‘0’. If ‘0’ is set, this function is not activated. In this default setting, the
connection is maintained even though there is no data transmission. In order to close the
connection, the ‘Close’ command should be given.
This function can be used for more than two or more systems to connect to a WIZ1000 module.
If one system holds the connection to the WIZ1000, other systems cannot connect to the
module. If there is no data transmission during the time defined in Inactivity time, the
connection will be closed for other system to be connected.
This function is for module configuration not through network with Configuration tool but
through serial communication. When you want to set via serial communication, check
“enable”. Please detail about serial configuration refers to “4. Serial Configuration”.
ⓦ Search Password
For the security issues, WIZ1000 can have its own password for searching. The password is
stored in the EEPROM of WIZ1000, and it can be modified via this configuration tool. The
password can be any alphabet or number. Its length can be variable and its maximum length
is 8 bytes. The password is case sensitive and the default password is ‘wiznet’.
ⓧConnection Password
‘Connection Password’ function is for blocking client’s access which is not allowed.
’Connection Password’ function can be operated only in ‘TCP Server’ mode. When ‘password’
function operates, clients should input password to access.
3. As shown in Figure 8, select Option tab and check 'Enable' combo box of "Password" menu.
4. Input password.
5. Click "Setting" button to apply password setting
6. When any client accesses the module, client should send 'password' to server module first,
and then access will be allowed.
The port of telnet and login password can also be defined by users. The maximum length of
telnet login password is 8 bytes and its default password is ‘wiznet’. The default telnet port is
23.
② If the module is properly connected to the network, “Complete Searching” message and
MAC address will be displayed on the “Search Result” as shown below Figure.
☞ Before uploading through Ethernet, you should set the network information of
WIZ1000 first by Configuration Tool program as shown above Fig 10. By using Ping test,
“Open” button.
⑥ When the firmware is uploaded successfully, the following message will be shown.
<Frame Format>
Reply Code
Reply Comments
S Command was successful
F Command failed
0 Invalid STX
1 Invalid command
2 Invalid parameter
3 Invalid ETX
E Enter serial command mode
Table 6. Serial Configuration Reply Code
① Check WIZ1000 Firmware version. If version is lower, download the latest firmware from
download page of http://www.wiznet.co.kr
② At the default status, the serial configuration is disabled. So, click ‘enable’ check box of
serial configuration and click ‘setting’ button. The defaut value of string is “+++”.
③ The testing can be processed as below, This testing is for checking module IP and
changing it to another.
WIZ1000 Ver.01.00
>Config socket : OK
>Listen : OK
<E><S><S192.168.11.3><S>
If the client is connected with WIZ1000, the disabled login frame and setting frame will be
enabled. If the telnet login password is set, you will get a login message. After login correctly,
the following configuration procedure can be started. Please note the default login password
of WIZ1000 is ‘wiznet’, and it can be modified through the option page by users.
Once the “Start!” button is clicked, the “WILL” command will be sent to WIZ1000. If WIZ1000
Power
Serial Cable
Reset
LAN Cable
z Above function can be tested by Device Terminal program that WIZnet is providing.
7.2. Specification
MCU 8051 Compliant
FLASH 62KByte (MCU Internal)
SRAM 16KByte (MCU Internal)
EEPROM 2KByte (MCU Internal)
7.3.2.1. RJ45
Pin Signal
1 TX+
2 TX-
3 RX+
6 RX-
7.3.2.2. RS-232
1 2 3 4 5
6 7 8 9
WIZnet Co., Ltd offers the following limited warranties applicable only to the original purchaser.
This offer is non-transferable.
WIZnet warrants our products and its parts against defects in materials and workmanship under
normal use for period of standard ONE(1) YEAR for the WIZ1000 board and labor warranty after
the date of original retail purchase. During this period, WIZnet will repair or replace a defective
products or part free of charge.
Warranty Conditions:
1. The warranty applies only to products distributed by WIZnet or our official distributors.
2. The warranty applies only to defects in material or workmanship as mentioned above in
6.Warranty. The warranty applies only to defects which occur during normal use and
does not extend to damage to products or parts which results from alternation, repair,
modification, faulty installation or service by anyone other than someone authorized by
WIZnet Inc. ; damage to products or parts caused by accident, abuse, or misuse, poor
maintenance, mishandling, misapplication, or used in violation of instructions furnished
by us ; damage occurring in shipment or any damage caused by an act of God, such as
lightening or line surge.