0% found this document useful (0 votes)
76 views

Multi Detector

The document provides information on two fire safety devices: 1. The S-A4014 Multisensor contains both a photoelectric smoke sensor and a thermistor to detect a wide range of fires unaffected by environmental conditions. 2. The S-A4051 Isolator Module is placed along detector loops to isolate short circuits so they only affect the section between isolators, automatically restoring power when short circuits are removed. 3. Both devices have technical specifications including operating voltages, current draw, temperature range, and dimensions.

Uploaded by

Tarik
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
76 views

Multi Detector

The document provides information on two fire safety devices: 1. The S-A4014 Multisensor contains both a photoelectric smoke sensor and a thermistor to detect a wide range of fires unaffected by environmental conditions. 2. The S-A4051 Isolator Module is placed along detector loops to isolate short circuits so they only affect the section between isolators, automatically restoring power when short circuits are removed. 3. Both devices have technical specifications including operating voltages, current draw, temperature range, and dimensions.

Uploaded by

Tarik
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SHIELD

Addressable Fire Detectors and Standard Base

S-A4014 Multisensor
...................................................................................................................................................................................................................................................................................

SHIELD Multisensor contains a photo-electric smoke sensor and a thermistor


(temperature sensor) whose outputs are combined to give the final analog
value.

• Sensitive to a wide range of fires


• Well suited for environments such as hotel bedrooms, warehouses &
loading docks
• Unaffected by wind or atmospheric pressure

Technical Data
Detector Type Photoelectric smoke sensor and Thermistor
Working Voltage 17 - 28 VDC
Modulation Voltage 5-9V
(V peak to peak)
Maximum Alarm Current LED on 3.5mA
Surge Current 0mA
Supervisory Current 500μA
Test Method Home safeguard, Gemini 501
Dimensions (diameter x height) 100mm x 50mm
Weight 105g

S-A4051 Isolator Module


...................................................................................................................................................................................................................................................................................

The Isolator is placed at intervals on the loop and ensures that, in the case of a
short circuit, only the section between the isolators will be affected. When the
short circuit is removed, the isolators automatically restore power and data
to the isolated section.
• Detects wiring short-circuits using patented technology
• Minimizes disruption from short-circuits
• Automatic de-isolation on short-circuit removal
• Up to 20 devices may be installed between isolators

Technical Data
Device Type Isolator
Style Mounting Base and twist-in isolator module
Working Voltage 17 - 28 VDC
Operating Current Modulation Voltage 5 - 9 V (peak to peak)
Supervisory Current 110μA
Surge Current 0mA
Maximum Current drawn 8.5mA
Maximum Line Impedance 50Ω
Temprature Range 0°C to 38°C
Dimensions (diameter x height) 100mm x 31.25mm
Weight 82g

Ordering Information
S-A4051 Isolator module
S-A4002 Isolator base
Note: Specifications are subject to change without notice