Wonderware Silo - Tips - Alarm-Db-Logger-Object-For-Wonderware-Application-Server-Demo-Guide-Ver-10-Rev-10

This 3 sentence summary provides the high level details about configuring and running the Alarm DB Logger demo: The document provides instructions for installing the Alarm DB Logger software, configuring the alarm databases and Wonderware objects, and viewing alarms logged to the databases. Two alarm databases are created and configured for alarms and events. Wonderware objects are set up to log alarms and events to the appropriate databases. The InTouch application is then run to generate sample alarms and view them logged in the alarm and event databases.

Uploaded by

Dino Pradana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
249 views20 pages

Wonderware Silo - Tips - Alarm-Db-Logger-Object-For-Wonderware-Application-Server-Demo-Guide-Ver-10-Rev-10

This 3 sentence summary provides the high level details about configuring and running the Alarm DB Logger demo: The document provides instructions for installing the Alarm DB Logger software, configuring the alarm databases and Wonderware objects, and viewing alarms logged to the databases. Two alarm databases are created and configured for alarms and events. Wonderware objects are set up to log alarms and events to the appropriate databases. The InTouch application is then run to generate sample alarms and view them logged in the alarm and event databases.

Uploaded by

Dino Pradana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

Alarm DB Logger Object

for Wonderware
Application Server

Demo Guide
Ver 1.0 Rev 1.0

WONDERWARE FINLAND
P.O. Box 38
FIN-00371 Helsinki Finland
tel. int. + 358 9 5404940
fax int. + 358 9 5413541
www.klinkmann.com
Wonderware Finland Alarm Extension Pack Demo Guide i

Table of Contents
Alarm DB Logger Demo ................................................................................................. 1
Software requirements................................................................................................ 1
Installation .................................................................................................................. 1
Configuration .............................................................................................................. 2
Alarm database creation ......................................................................................... 2
Logger configuration ................................................................................................... 7
WAS object configuration ........................................................................................... 10
aAlarm_DBLogger_Alarms...................................................................................... 10
eAlarm_DBLogger_Events ...................................................................................... 11
InTouch Application .................................................................................................... 12

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide 1

Alarm DB Logger Demo

Software requirements
Alarm DB Logger demo requires WAS (Wonderware Application Server) 3.1 SP3
or later and InTouch 10.1 SP2 or later installed.

Installation
1. Create a new galaxy or use existing galaxy for this demo installation.

2. Create and Configure WinPlatform (WinPlatform_001) object with enabled


alarming if it does not exists already:

3. Import demo objects (AEP_DemoVer1.aaPKG) into galaxy:

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide 2

Note: this package already contains Alarm DB Logger object and Alarm Gateway object
no separate imports are required.

Configuration
Following steps is needed to configure and run Alarm DB Logger demo.

Alarm database creation


For this demo 2 alarm databases (named wwAlarms
And wwEvents) with following configuration are needed:

1) Run Alarm DB Logger application (Alarm DB logger object do not have


functionality to create Alarm database):

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide 3

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide 4

2) Press Settings button:

3) Enter configuration for first alarm database

 Database – wwAlarms
 Password – current sa account password

4) Press Create button and new alarm database is created:

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide 5

5) Press OK button and enter second wwEvent database configuration:

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide 6

 Database – wwEvents
 Password – current sa account password.

6) Press Create button and new alarm database is created:

7) Press OK button and exit Alarm DB Logger application by pressing Cancel button and
close Alarm DB Logger Manager application.

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide 7

Logger configuration
To avoid log messages “Invalid alarm transition state found in FormatAlarmRecord
function”, uncheck UNKNOWN component Log Flag Info:

1) Run System Management Console:

2) Select Log Viewer component, expand to Local group and right click it for context
menu:

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide 8

3) Browse to Unknown component and uncheck UNKNOWN component Log Flag Info:

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide 9

4) Close Log flag editor and save changes:

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide
10

WAS object configuration


Following objects are needed to configure before deploying demo objects.

aAlarm_DBLogger_Alarms
This object at runtime sets alarm database connection configuration for object
AlarmDBLogger_Det_Alarms

1) Configure aAlarm_DBLogger_Alarms object script Ini – set for SQL server password
and user name. sa password SQL.Password

Logmessage("auto set config for AlarmDBLogger_Det_Alarms");

AlarmDBLogger_Det_Alarms.Consumer.AlarmQuery = "\Galaxy!F1";
'"\AlarmGatewayProvider!F1"; ' connect to
AlarmDBLogger_Det_Alarms.SQL.ServerName = "LOCALHOST";
AlarmDBLogger_Det_Alarms.SQL.Database = "wwAlarms";

AlarmDBLogger_Det_Alarms.SQL.User = "sa";
AlarmDBLogger_Det_Alarms.SQL.Password = "x";

AlarmDBLogger_Det_Alarms.Consumer.QueryMode = 1; ' 1 - alarms 2 - events 3 -


both
AlarmDBLogger_Det_Alarms.SQL.LoggingMode = 1;' Alarm Logging Mode 1 - detailed
2 - Consolidated
AlarmDBLogger_Det_Alarms.Restart = true;

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide
11

eAlarm_DBLogger_Events
This object at runtime sets alarm database connection configuration for object
AlarmDBLogger_Det_Alarms and AlarmDBLogger_Det_Events)

1) Configure aAlarm_DBLogger_Alarms object script Ini – set for SQL server password
and user name. sa password SQL.Password

Logmessage("auto set config for AlarmDBLogger_Det_Events");

AlarmDBLogger_Det_Events.Consumer.AlarmQuery = "\Galaxy!F1";
AlarmDBLogger_Det_Events.SQL.ServerName = "LOCALHOST";
AlarmDBLogger_Det_Events.SQL.Database = "wwEvents";

AlarmDBLogger_Det_Events.SQL.User = "sa";
AlarmDBLogger_Det_Events.SQL.Password = "x;

AlarmDBLogger_Det_Events.Consumer.QueryMode = 2; ' 1 - alarms 2 - events 3 -


both
AlarmDBLogger_Det_Events.SQL.LoggingMode = 1;' Alarm Logging Mode 1 - detailed
2 - Consolidated
AlarmDBLogger_Det_Events.Restart = true;

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide
12

2) After object AlarmDBLogger_AutoConfig is configured save object configuration and


deploy all objects.

InTouch Application
Run managed InTouch application Demo_AEP_001.

1) All Extension Pack objects requires license to run, enter demo license code below:

3B 21 3A 99 27 9F 2C 0C B1 CC A8 7F 4B 94 D2 9B 6B 11 90 B4 64 AC D4 56 E6 F7 9B
33 EC 2E A4 47

Click on text Enter here:

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide
13

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide
14

2) Enter same Demo License key also for both Alarm DB Logger objects:

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide
15

3) After all objects are licensed after 15-20 seconds both Alarms views are filled with
alarms:

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide
16

UReason alarming system

1) Alarm Gateway object can transfer Alarms to UReason alarming system to


configure alarm gateway for connection to UReason enter computer IP were UReason
alarm system is running and UReason alarming system user and password:

2) And press button Restart to establish connection to UReason alarming system.

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide
17

Alarm DB Logger Demo Guide Rev 1.0 AlarmDBLoggerDemoGuide10


Wonderware Finland Alarm Extension Pack Demo Guide
18

WONDERWARE FINLAND
Alarm DB Logger Demo Guide
Revision History

Oct 2011 Rev 1.0 First Release