Upper Ground Floor To 2nd Floor

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 3

Wind Along X

Upper Ground Floor to 2nd Floor

Windward

( 4.370
@C 1 , P=1529.1414
2 ) N
=3341.17396 →3.3412
m
kN
m

@C , P=1529.1414 ( )
4.370+ 3.5 kN
2 =6017.1714 → 6.0172
2 m

@C , P=1529.1414 ( )
3.5+3.8 N kN
3 =5581.3661 → 5.5814
2 m m

@C , P=1529.1414 (
2 )
3.8 N kN
4 =2905.3687 → 2.9054
m m

Sidewall

@C 1 , P=−1594.8307( 3.52 )=−2790.9537 Nm →−2.7910 kNm


@C , P=−1594.8307 ( )
3.5+4.5 N kN
2 =−6379.3228 →−6.3793
2 m m

@C , P=−1594.8307 ( )
4.5 N kN
3 =−3588.3691 →−3.5884
2 m m

Leeward

@C 1 , P=−1244.9968( 4.372 )=−2720.318 Nm →−2.7203 kNm


@C , P=−1244.9968 ( )=−4899.062 Nm →−4.8991 kNm
4.37+3.5
2
2

@C , P=−1244.9968 ( )
3.5+3.8 N kN
3 =−4544.2383 →−4.5442
2 m m

@C , P=−1244.9968 ( )
3.8 N kN
4 =−2 365.4939 →−2.3655
2 m m
Wind Along Z

Upper Ground Floor to 2nd Floor

Windward

( 3.52 )=2675.9975 Nm → 2.6760 kNm


@C 1 , P=1529.1414

@C , P=1529.1414 ( )
3.5+ 4.5 N kN
2 =6116.5656 → 6.1166
2 m m

@C , P=1529.1414 ( )
4.5 N kN
3 =3440.5682 → 3.4406
2 m m

Sidewall

@C 1 , P=−1594.8307( 4.372 )=−3484.7051 Nm →−3.4847 kNm


@C , P=−1594.8307 ( )
4.37+ 3.5 N kN
2 =−6275.6588 →−6.2757
2 m m

@C , P=−1594.8307 ( )
3.5+3.8 N kN
3 =−5821.1321 →−5.8211
2 m m

@C , P=−1594.8307 ( )
3.8 N kN
4 =−3030.1783 →−3.0302
2 m m

Leeward

@C 1 , P=−989.7931( 3.52 )=−1732.1379 Nm →−1.7321 kNm


@C , P=−989.7931 ( )
3.5+4.5 N kN
2 =−3959.1724 →−3.9592
2 m m

@C , P=−989.7931 ( )
4.5 N kN
3 =−2227.0344 →−2.227
2 m m
Table of Summary for Upper Ground Floor to 2 nd Floor
Wind Along X Wind Along Z
Column Windward P- kN/m Windward P- kN/m
1 3.3412 2.6750
2 6.0172 6.1166
3 5.5814 3.4406
4 2.9054
Column Sideward P- kN/m Sideward P- kN/m
1 -2.791 -3.4847
2 -6.3793 -6.2757
3 -3.5884 -5.8211
4 -3.0302
Column Leeward P- kN/m Leeward P- kN/m
1 -2.7203 -1.7321
2 -4.8991 -3.9592
3 -4.5442 -2.227
4 -2.3655

You might also like