0% found this document useful (0 votes)
92 views2 pages

JDM9 en

The JDM9 series preset counter manual describes a counter that is: 1. Used widely in industrial control systems for its anti-jamming and high reliability. 2. Has standard dimensions of 72x72mm and adheres to international standards. 3. Counts up to 999999 with a high accuracy crystal oscillator frequency splitting technique.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
92 views2 pages

JDM9 en

The JDM9 series preset counter manual describes a counter that is: 1. Used widely in industrial control systems for its anti-jamming and high reliability. 2. Has standard dimensions of 72x72mm and adheres to international standards. 3. Counts up to 999999 with a high accuracy crystal oscillator frequency splitting technique.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

JDM9 series preset counter manual

▇ Features
1. Strong anti-jamming, high reliability, used widely in industrial control systems.
2. Standard Dimensions (72x72mm), geared to international standards
3. Adopt high frequency crystal oscillator frequency splitting technique, with high accuracy.
4. 4. Time range is wide, max is 999999
5. 5. Fit to GB14048.5-2001 and JB/T JB/T 8794-1998 relevant provision.
6. Strictly produce according to standard, 9 working procedures and 5 times strict inspections.

▇ Apply range

Mainly used in industrial control systems, used widely at Petroleum, chemical, textile, machinery,
mining, national defence, agriculture, food, printing etc, Please make twice protection when use this
product to control precious equipment or the occasion which imperil person's life.

▇ Main technical parameter

om
Supply voltage Refer to the label of case, the Mechanical ≥1x106 ops
voltage fluctuation is life
85%-110%Ur
Power consumption
Counting range
≤3VA
JDM9-4: 1-9999; .c
JDM9-6:
Electrical life
Reset mode
≥1x105 ops
Press the panel pushbutton
ai
1-999999 or short circuit between 3,4
terminals
≥0.05s
l
Counting speed 30 cps max, the min count Pause time
ng

pulse width is 150ms


Auxiliary power DC12V (schematically) 25mA Power restart ≥1s
Input signal Contact, level, sensor, can be Counting ≤1
.fi

selected error
Contact quantity 1 group passive contacts output Mounting Panel type
w

type
Contact rating 3A@250Vac/5A@24Vdc Perforation 72x72mm
w

dimensions
Operating -5℃—45℃ No-power Can choose to keep the data
w

temperature memory or not, if keep, can remain 10


years
Store temperature -20℃—70℃

▇ Electric characteristic

Insulation 100MΩ min at 500Vdc Dielectric 2000Vac, 50/60Hz for 1min


resistance strength
Anti-jamming EFT execute GB/T17626-4 impact Impact resistance: 30G X、Y、Z direction 3
level times each
Anti-jamming ESD execute GB/T17626-3 impact Malfunction: 10G X、Y、Z direction 3 times
level each
vibration Shock resistance: 10-50Hz(1min periods) 0.75mm swing, X、Y、Z direction 1h each
vibration Malfunction: 10-55Hz(1min periods) 0.5mm swing, X、Y、Z direction 1min each
▇ External dimensions and Perforation dimensions (Unit: mm)
78 78 123 70

70
9 9 9 9 9 9

▇ Wiring diagram

12 11 10 9 8 7 12 11 10 9 8 7 12 11 10 9 8 7

Reset Reset Reset

1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6
UP counting

om
+12V CP GND +12V CP CP GND
Low level DC0-2V
BN BK BU BN BK +12V High level DC6-36V
(+) (-) PNP sensor (+) (-) (+) (-)
Power Power Count Power Count

Sensor input Contact input Level input

.c
ai
▇ Use description:
l
1. Please preset the count value before connecting to the power, it is invalid when set the value after
ng

power, the power supply re-start interval is ≥1 seconds.


.fi

2. Reset function: you can connect the reset terminals or press the panel reset button at any
power-on time, relay will return to the initial state.
w

3. In strong electrical environment or the count terminal cables are with long cable, please use a
w

shielded wire, if the input is sensor, recommended the working power DC6-36V sensors.
w

4. Reset terminal and add / minus count terminal is passive contact control mode, do not input
voltage, to avoid damaging the relay

▇ Product list

Host, panel mounting card, dust-proof cap, manual.