ACCURET-A20 Product Specifications

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ACCURET-A20

Actuator, AISG 2.0 default protocol

Connects to the base station antenna for remote electrical tilt


Easy to install; no tools required
Easily mounts to back of antenna
Factory set to AISG 2.0 mode

This product will be discontinued on: March 31, 2023

Product Classification
Product Type RET actuator

General Specifications
AISG Input Connector 8-pin DIN Male

AISG Input Connector Quantity 1

AISG Output Connector 8-pin DIN Female

AISG Output Connector Quantity 1

Color Black

Dimensions
Height 205 mm   |   8.071 in

Width 125 mm   |   4.921 in

Depth 50 mm   |   1.969 in

Electrical Specifications
Input Voltage 10–30 Vdc

Adjustment Cycles, minimum 10000 cycles

Adjustment Time, full range, maximum 30 s

Default Protocol AISG 2.0

Electromagnetic Compatibility (EMC) CFR 47 Part 15, Subpart B, Class A    |   EN 55022

Interface Protocol Signal RS-485

Lightning Surge Capability 5 times @ -10 kA    |   5 times @ 10 kA


Page 1 of 2

©2022 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: April 14, 2022
ACCURET-A20
Lightning Surge Capability Test Method IEC 61000-4-5

Lightning Surge Capability Waveform 1.2/50 voltage and 8/20 current combination waveform

Lightning Surge Test Mode Common mode

Protocol AISG 2.0

Material Specifications
Material Type ABS

Environmental Specifications
Operating Temperature -40 °C to +70 °C (-40 °F to +158 °F)

Climatic Sequence Test Method IEC 60068-2-14

Cold Exposure Test Method IEC 60068-2-1

Corrosion Test Method IEC 60068-2-11, Test Condition Ka    |   IEC 60068-2-52, Test Condition Kb

Damp Heat Exposure Test Method IEC 60068-2-30, Test Condition Db

Heat Exposure Test Method IEC 60068-2-2

Ingress Protection Test Method IEC 60529:2001, IP56

Packaged Product Shock Test Method ASTM D4169    |   GR-63-CORE, Section 4.1.1

Rain Simulation Test Method IEC 60068-2-18, Test Condition Ra, Method 1

UV Resistance Test Method IEC 60068-2-5, Test Condition B

Vibration Test Method ASTM D4169    |   IEC 60068-2-6

Packaging and Weights


Weight, net 0.5 kg   |   1.102 lb

Regulatory Compliance/Certifications
Agency Classification
CE Compliant with the relevant CE product directives
CHINA-ROHS Above maximum concentration value
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
ROHS Compliant/Exempted

Page 2 of 2

©2022 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: April 14, 2022

You might also like