Echnical Ulletin: Important Information About Normal/Smart Panel Firmware Updates
Echnical Ulletin: Important Information About Normal/Smart Panel Firmware Updates
Echnical Ulletin: Important Information About Normal/Smart Panel Firmware Updates
Reissued: 09-Mar-17
Model: Cor-C1 / Cor-C1_SOP Date: 05-Sep-14 No.: RD197002d
RTB Reissue
The items in bold italics have been corrected or added.
Subject: Firmware Release Note: browser Prepared by: H. Morishima
From: 2nd Tech Service Sect., MFP/Printer Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the browser.
Symptom corrected:
- When a certain page is loaded or printed, an SC899 might occur.
1.05.00 Symptom corrected:
- Keyboard response is slow when using the Web Scanner application.
- SC899 may occur when performing Java Script functions.
1.04.00 Version number changed for version management purposes (No program changes
made).
1.03.00 Symptom corrected
SC899 may occur when performing continuous scanning.
1.02.00 1st Mass production
Technical Bulletin PAGE: 2/2
Reissued: 09-Mar-17
Model: Cor-C1 / Cor-C1_SOP Date: 05-Sep-14 No.: RD197002d
Technical Bulletin PAGE: 1/1
Reissued: 01-Sep-15
Model: Cor-C1 / Cor-C1_SOP Date: 05-Sep-14 No.: RD197003c
RTB Reissue
The items in bold italics have been corrected or added.
Subject: Firmware Release Note: Extended JS Prepared by: T. Tachibana
From: 1st Tech Service Sect., MFP/Printer Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the Extended JS.
This RTB has been issued to announce the firmware release information for the GWFCU3.8-7
(WW).
This RTB has been issued to announce the firmware release information for the NetworkDocBox.
Other changes:
Technical Bulletin PAGE: 2/2
Reissued: 27-Jan-17
Model: Cor-C1 / Cor-C1_SOP Date: 05-Sep-14 No.: RD197005f
Version Modified Points or Symptom Corrected
- Support for user code authentication in applications that use Web Browser NX.
1.06 Symptom corrected:
- If a user logs in to a device via Basic Authentication just after the device is started up,
the Smart Operation Panel application may not work as expected.
- Pressing the copy program button may cause the operation panel to become inactive
for 30 sec followed by SC997.
1.05 Other changes:
Changes were applied for the domestic (Japan) model only.
1.04 Other Change:
- Supported RICOH SmartSDK v1.04.
1.03 Symptom corrected:
- SC997 will occur if a user logs in to an MFP via an SDK application when the device
management software is collecting the Volume Use Counter.
1.02 1st Mass production
Technical Bulletin PAGE: 1/1
Model: Cor-C1 / Cor-C1_SOP Date: 05-Sep-14 No.: RD197006
This RTB has been issued to announce the firmware release information for the Option Netware.
This RTB has been issued to announce the firmware release information for the PDF.
Note that this f/w must be used in combination with printer f/w v.1.05 or later.
1.02 1st Mass production
Technical Bulletin PAGE: 1/1
Reissued: 16-Apr-15
Model: Cor-C1 / Cor-C1_SOP Date: 05-Sep-14 No.: RD197009a
RTB Reissue
The items in bold italics have been corrected or added.
Subject: Firmware Release Note: PowerSaving Sys Prepared by: T. Hirakawa
From: 2nd Tech Service Sect., MFP/Printer Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the PowerSaving Sys.
This RTB has been issued to announce the firmware release information for the RPCS.
This RTB has been issued to announce the firmware release information for the Web Uapl.
This RTB has been issued to announce the firmware release information for the aics.
This RTB has been issued to announce the firmware release information for the animation.
Reissued: 22-Feb-16
Model: Cor-C1/Cor-C1_SOP/GR-C2_SOP/Lef-C1 Date: 05-Sep-14 No.: RD197027b
RTB Reissue
The items in bold italics have been corrected or added.
Subject: Firmware Release Note: Data Erase Onb Prepared by: T. Tachibana
From: 1st Tech Service Sect., MFP/Printer Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the Data Erase Onb.
This RTB has been issued to announce the firmware release information for the CSPF.
This RTB has been issued to announce the firmware release information for the CheetahSystem.
Other changes:
Affected models: MP C2003/2503 Smart Operation panel models only
3. The banner message that appears when a tray ascend/descend error occurs was
changed to indicate the tray.
For this release to take effect, make sure to update animation v.14.00 (D1765564D)
or later as a set.
1.50 Symptom corrected:
- Applications may disappear from the home screen, if logged on to a machine set with the
custom authentication.
- The screen may suddenly black out while using the operation panel.
Other changes:
Applications for the smart operation panel can be installed, un-installed, and updated using
Remote tools such as DMNX.
1.49 Symptom corrected:
- Operation panel does not start up, if the machine was left unused for an extended period
in energy saver mode.
- Keys on the preview screen become unresponsive, if repeatedly logged in to and logged
out of the screen on the simple scanner application.
- If an address of a user registered with an authentication without a fax address is
selected in the simple FAX application, the selection cannot be canceled.
- Cannot scroll the address list in the simple FAX application depending on the number of
the addresses contained in the list.
- The operation panel may stall with the message "Please wait" displayed, if a non-legacy
(classic) application is used for an extended period.
- The operation panel may stall with the message "Processing" displayed, if attempted to
start up the on-demand print application.
1.48 Symptom corrected:
- Through the Stagefright vulnerability (CVE-2015-1538), a malicious attack can be
conducted when an infected video file on a USB memory drive, an SD card, or a
website is played.
- Copy/Scanner/Fax show the state of jobs as being conducted immediately after the
device is rebooted.
- Webpages might not be displayed properly in the web browser when connected to a
proxy server.
- Operation panel stalls at the log in screen.
Others:
Security of user information was enhanced in the process of obtaining Smart Operation
Panel logs.
1.47 Symptom corrected:
The Cheetah operation panel may falsely detect a multi-touch.
1.46 Error Correction:
Technical Bulletin PAGE: 4/12
Reissued: 14-Mar-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/ MET-C1yz_SOP/ Date: 15-Aug-13 No.: RD147150g
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
Version Modified Points or Symptom Corrected
When a client device is connected to the Smart Operation Panel via Wi-Fi Direct, corporate
LAN environments connected via the network interface of the MFP can be accessed if the
following settings are configured:
- Wi-Fi Direct: Set to "Enable" (default: Disable)
- Port Forwarding: Set to "Enable" (default: Enable)
- Interface Settings: Set to "Machine Network" (default: Machine Network)
Please note that the Wi-Fi Direct setting is set to "Enable" when using the RICOH Smart
Device Connector.
1.45 Symptom corrected:
- Login screen appears even if "Home Key Customization: Login Setting (SP5-074-002)"is
set to "1(OFF)."
Important: To apply this change, in addition to this firmware, you also need to update
System/Copy firmware to the following version or later.
MP C2003/C2503 : 2.15(D1765550T)
MP C3003/C3503 : 3.15(D1465575B)
MP C4503/C5503/C6003 : 3.16(D1485553C)
- Some touch panel coordinates are shifted.
1.44 Symptom corrected:
Operation panel may stall, if it is kept ON for an extended period.
1.43 Specification Change:
Alert message appears when attempted to download files that are not supported of the
format, for example, PDF.
Symptom corrected:
Coordination of the touchscreen may shift.
Note that this firmware must be used in combination with Legacy UI version 1.29 or later.
1.42 Specification Change:
More detailed logs can be collected.
Symptom corrected:
HDD may not be accessible with Smart Operation Panel immediately after rebooting the
machine.
1.41 Symptom corrected:
Security issues was resolved.
1.40 Symptom corrected:
- Screen may flicker, if System Auto Reset is performed while displaying the preferred
application.
- The operation panel remains blank and there is no response from the hard keys or
touch panel following an RFU.
1.39 Symptom corrected:
1. "Wi-Fi Direct" in the Wireless & Networks settings has been renamed to "Wireless
Direct".
2. The SOP cannot recover from Energy Saver mode or cannot be used during the first
two minutes after device start-up under the following conditions:
- The Proxy settings are enabled on the SOP and,
- The domain name (specified as a proxy server) cannot be resolved.
1.38 Symptom corrected:
Technical Bulletin PAGE: 5/12
Reissued: 14-Mar-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/ MET-C1yz_SOP/ Date: 15-Aug-13 No.: RD147150g
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
Version Modified Points or Symptom Corrected
1. Users may access the app menu screen without Administrator privileges.
2. Apps may take a long time to be installed when the operation panel is connected via
direct connection.
3. Files cannot be forwarded from SOP apps to external Web servers.
1.37 Symptom corrected:
1. Network connection error may occur (e.g. Browser displays 'Web page not available')
when an application attempts to connect to the network, if the screen start up mode is
specified to 'quick' and the wireless & networks interface setting is specified to
'machine'.
1.35 Symptom corrected:
1. The Copy Interrupt screen is not displayed when the Interrupt key is pressed.
2. [Android App]: An error occurs when trying to download the log data.
3. [Streamline NX] (SDK app): The priority app does not start up when the machine
recovers from Energy Saver mode (the LUI and Launcher black screens appear in
alternation).
4. [Streamline NX] (SDK app): The following occurs after logging out of Streamline NX:
- A different SDK app is displayed and the user cannot switch over to another app, or
- A different SDK app is displayed, followed by Streamline NX
1.34 Symptom corrected:
1. [Operation Panel Browser]: Cannot print except when the language is set to English or
Japanese.
2. [Operation Panel Browser]: Cannot print if the user logs in with a blank password.
3. Machine does not enter Energy Saver mode for a while after the user repeatedly logs in
and logs out quickly.
4. The Home screen is displayed instead of the priority app when "Ubiquitech" has been
set as the priority app, and the machine is awoken from Energy Saver with a card login.
5. "Browser" appears on the settings screen if an app that uses the MFP browser's
Favorites (RAC ICE, OSK or eValue) has been set as the priority app.
6. Operation panel freezes/stalls if the machine enters or recovers from Energy Saver
mode during displaying the copy interrupt screen.
7. The login screen is not displayed after logging out of Stren.
8. No machine operations are possible following a cancelled login.
9. Cannot login if the timer sounds while the password login screen for password-
embedded IC cards is being displayed.
10. Logout is possible when the logout lock is enabled.
11. The icon for the RIS app. is not displayed on the Home screen when logging in via
Streamline NX.
12. Cannot login or logout if the user logs back in with an IC card just after logging out from
the System Settings screen.
13. SC998 occurs when card authentication package is installed.
14. The Home screen for the Smart Operation panel is displayed if the machine is brought
out of Energy Save mode just after it enters the mode via Streamline NX.
15. Cannot logout (only login button is displayed) if the Home key is pressed while the user
signs in via a customized UI authentication app.
16. The operation panel stalls (screen turns black) if the machine is repeatedly put into and
taken out of Energy Saver mode following a controller reboot in a customized
authentication environment.
Technical Bulletin PAGE: 6/12
Reissued: 14-Mar-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/ MET-C1yz_SOP/ Date: 15-Aug-13 No.: RD147150g
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
Version Modified Points or Symptom Corrected
17. The machine stalls if the [Home] button is pressed just as the screen turns dark to
transition to Energy Saver mode (following the pressing of the Streamline NX Energy
Saver button).
18. Machine cannot enter Energy Saver mode while Streamline NX continues to operate.
1.33 Symptom corrected:
"Commencing forced shut-down" is displayed on the Smart Operation Panel when the
machine is turned ON.
1.32 Symptoms corrected:
1. Cannot return to Ready/stand-by mode from Sleep mode due to leakage current.
2. An error occurs when processing the SSID and password of a Wi-Fi direct network.
3. Cannot access NAT connection in quick recovery.
4. Icons do not show up after reconnection.
5. Incorrect user account access rights are sent to the SSDK application.
Other changes:
1. Supports Web application API V1.02.
2. Supports QR code applications
3. The WiFi channel was changed.
4. G1.5 system remote F/W update
1.30 Symptom corrected:
1. Printing from the browser (Smart Operation Panel) fails if the user has signed in with a
multi-byte user ID and password.
2. A user account without access rights to the browser may be displayed inside the
authentication UI customized app as having these access rights ("Authorized for
browsing").
3. An error dialog is displayed and login is not possible if the user tries the login without a
user name.
Other changes:
1. Web application API V1.01
2. Supports business sineage apps for the Smart Operation Panel.
1.29 Speification Change
1. Supports Wi-Fi Direct Printing
Error Corrected:
1. Garbled Chinese characters
2. Data-in LED turns is ON when the machine enters Energy Saver mode following a
machine reboot.
3. Data-in LED turns ON when the engine reaches off status if the machine is rebooted
(turned OFF/ON) during a job.
4. The machine does not recover from Energy Saver mode.
5. Translation errors in Russian.
6. Job Stop screen is not displayed when the Stop key is pressed while the user is logged
out of Simple Copy mode.
7. The previous screen appears if the user logs out from the 'linkage failed' screen.
8. Display does not return to Home screen if the Home button is pressed right after the Job
History tab is pressed.
9. Wording errors in several languages were corrected (Cloud FAX).
Technical Bulletin PAGE: 7/12
Reissued: 14-Mar-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/ MET-C1yz_SOP/ Date: 15-Aug-13 No.: RD147150g
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
Version Modified Points or Symptom Corrected
10. Stop key does not respond while the user is logged out.
11. LUI is displayed when a system reset is performed after completing import/export.
12. Display does not return to the Home screen if the Home key is pressed after the
machine recovers from Sleep mode.
1.28 Specification change:
Added support for using external tools to install applications on the Smart Operation Panel.
1.25 Symptom corrected:
1. Duplicates of the Printer, Scanner, and FAX icons appear when the main power is
turned OFF/ON after the display language is changed.
Other changes:
2. The machine hard disk can now be used by applications displayed on the Smart
Operation Panel.
IMPORTANT: To apply this change, update the System/Copy firmware to v3.00
(D1485550K/D1465550L) or later.
1.24 Symptom corrected:
The Smart Operation Panel unit does not reach the Ready condition.
Other changes:
Some words in Portuguese have been revised in accordance with new spelling changes
made to the Portuguese language.
1.22 Symptom corrected:
1. The application icon does not respond after the machine reboots automatically after an
SC.
2. The beep sound can still be heard even when the Warm-up Beeper setting (User Tools)
is turned OFF.
1.20 Symptom corrected:
1. Some touch panel coordinates are shifted.
2. The SC screen is not displayed and the Home key does not respond if an SC error
occurs while the status confirmation screen is displayed.
1.19 Symptom corrected:
1. Usernames registered using simplified Chinese characters will appear garbled in the
upper and lower banners after login.
2. Minor bug correction
1.17 1st Mass production
Other changes:
Affected models: MP C2003/2503 Smart Operation panel models only
Technical Bulletin PAGE: 8/12
Reissued: 14-Mar-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/ MET-C1yz_SOP/ Date: 15-Aug-13 No.: RD147150g
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
Version Modified Points or Symptom Corrected
3. The banner message that appears when a tray ascend/descend error occurs was
changed to indicate the tray.
For this release to take effect, make sure to update animation v.14.00 (D1765564D)
or later as a set.
1.50 Symptom corrected:
- Applications may disappear from the home screen, if logged on to a machine set with the
custom authentication.
- The screen may suddenly black out while using the operation panel.
Other changes:
Applications for the smart operation panel can be installed, un-installed, and updated using
Remote tools such as DMNX.
1.49 Symptom corrected:
- Operation panel does not start up, if the machine was left unused for an extended
period in energy saver mode.
- Keys on the preview screen become unresponsive, if repeatedly logged in to and logged
out of the screen on the simple scanner application.
- If an address of a user registered with an authentication without a fax address is
selected in the simple FAX application, the selection cannot be canceled.
- Cannot scroll the address list in the simple FAX application depending on the number of
the addresses contained in the list.
- The operation panel may stall with the message "Please wait" displayed, if a non-legacy
(classic) application is used for an extended period.
- The operation panel may stall with the message "Processing" displayed, if attempted to
start up the on-demand print application.
1.48 Symptom corrected:
- Through the Stagefright vulnerability (CVE-2015-1538), a malicious attack can be
conducted when an infected video file on a USB memory drive, an SD card, or a
website is played.
- Copy/Scanner/Fax show the state of jobs as being conducted immediately after the
device is rebooted.
- Webpages might not be displayed properly in the web browser when connected to a
proxy server.
- Operation panel stalls at the log in screen.
Others:
Security of user information was enhanced in the process of obtaining Smart Operation
Panel logs.
1.47 Symptom corrected:
The Cheetah operation panel may falsely detect a multi-touch.
1.46 Error Correction:
When a client device is connected to the Smart Operation Panel via Wi-Fi Direct, corporate
LAN environments connected via the network interface of the MFP can be accessed if the
following settings are configured:
- Wi-Fi Direct: Set to "Enable" (default: Disable)
- Port Forwarding: Set to "Enable" (default: Enable)
- Interface Settings: Set to "Machine Network" (default: Machine Network)
Technical Bulletin PAGE: 9/12
Reissued: 14-Mar-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/ MET-C1yz_SOP/ Date: 15-Aug-13 No.: RD147150g
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
Version Modified Points or Symptom Corrected
Please note that the Wi-Fi Direct setting is set to "Enable" when using the RICOH Smart
Device Connector.
1.45 Symptom corrected:
- Login screen appears even if "Home Key Customization: Login Setting (SP5-074-002)"is
set to "1(OFF)."
Important: To apply this change, in addition to this firmware, you also need to update
System/Copy firmware to the following version or later.
MP C2003/C2503 : 2.15(D1765550T)
MP C3003/C3503 : 3.15(D1465575B)
MP C4503/C5503/C6003 : 3.16(D1485553C)
- Some touch panel coordinates are shifted.
1.44 Symptom corrected:
Operation panel may stall, if it is kept ON for an extended period.
1.43 Specification Change:
Alert message appears when attempted to download files that are not supported of the
format, for example, PDF.
Symptom corrected:
Coordination of the touchscreen may shift.
Note that this firmware must be used in combination with Legacy UI version 1.29 or later.
1.42 Specification Change:
More detailed logs can be collected.
Symptom corrected:
HDD may not be accessible with Smart Operation Panel immediately after rebooting the
machine.
1.41 Symptom corrected:
Security issues was resolved.
1.40 Symptom corrected:
- Screen may flicker, if System Auto Reset is performed while displaying the preferred
application.
- The operation panel remains blank and there is no response from the hard keys or
touch panel following an RFU.
1.39 Symptom corrected:
1. "Wi-Fi Direct" in the Wireless & Networks settings has been renamed to "Wireless
Direct".
2. The SOP cannot recover from Energy Saver mode or cannot be used during the first
two minutes after device start-up under the following conditions:
- The Proxy settings are enabled on the SOP and,
- The domain name (specified as a proxy server) cannot be resolved.
1.38 Symptom corrected:
1. Users may access the app menu screen without Administrator privileges.
2. Apps may take a long time to be installed when the operation panel is connected via
direct connection.
3. Files cannot be forwarded from SOP apps to external Web servers.
1.37 Symptom corrected:
1. Network connection error may occur (e.g. Browser displays 'Web page not available')
when an application attempts to connect to the network, if the screen start up mode is
Technical Bulletin PAGE: 10/12
Reissued: 14-Mar-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/ MET-C1yz_SOP/ Date: 15-Aug-13 No.: RD147150g
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
Version Modified Points or Symptom Corrected
specified to 'quick' and the wireless & networks interface setting is specified to
'machine'.
1.35 Symptom corrected:
1. The Copy Interrupt screen is not displayed when the Interrupt key is pressed.
2. [Android App]: An error occurs when trying to download the log data.
3. [Streamline NX] (SDK app): The priority app does not start up when the machine
recovers from Energy Saver mode (the LUI and Launcher black screens appear in
alternation).
4. [Streamline NX] (SDK app): The following occurs after logging out of Streamline NX:
- A different SDK app is displayed and the user cannot switch over to another app, or
- A different SDK app is displayed, followed by Streamline NX
1.34 Symptom corrected:
1. [Operation Panel Browser]: Cannot print except when the language is set to English or
Japanese.
2. [Operation Panel Browser]: Cannot print if the user logs in with a blank password.
3. Machine does not enter Energy Saver mode for a while after the user repeatedly logs in
and logs out quickly.
4. The Home screen is displayed instead of the priority app when "Ubiquitech" has been
set as the priority app, and the machine is awoken from Energy Saver with a card login.
5. "Browser" appears on the settings screen if an app that uses the MFP browser's
Favorites (RAC ICE, OSK or eValue) has been set as the priority app.
6. Operation panel freezes/stalls if the machine enters or recovers from Energy Saver
mode during displaying the copy interrupt screen.
7. The login screen is not displayed after logging out of Stren.
8. No machine operations are possible following a cancelled login.
9. Cannot login if the timer sounds while the password login screen for password-
embedded IC cards is being displayed.
10. Logout is possible when the logout lock is enabled.
11. The icon for the RIS app. is not displayed on the Home screen when logging in via
Streamline NX.
12. Cannot login or logout if the user logs back in with an IC card just after logging out from
the System Settings screen.
13. SC998 occurs when card authentication package is installed.
14. The Home screen for the Smart Operation panel is displayed if the machine is brought
out of Energy Save mode just after it enters the mode via Streamline NX.
15. Cannot logout (only login button is displayed) if the Home key is pressed while the user
signs in via a customized UI authentication app.
16. The operation panel stalls (screen turns black) if the machine is repeatedly put into and
taken out of Energy Saver mode following a controller reboot in a customized
authentication environment.
17. The machine stalls if the [Home] button is pressed just as the screen turns dark to
transition to Energy Saver mode (following the pressing of the Streamline NX Energy
Saver button).
18. Machine cannot enter Energy Saver mode while Streamline NX continues to operate.
1.33 Symptom corrected
"Commencing forced shut-down" is displayed on the Smart Operation Panel when the
machine is turned ON.
1.32 Symptoms corrected:
Technical Bulletin PAGE: 11/12
Reissued: 14-Mar-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/ MET-C1yz_SOP/ Date: 15-Aug-13 No.: RD147150g
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
Version Modified Points or Symptom Corrected
1. Cannot return to Ready/stand-by mode from Sleep mode due to leakage current.
2. An error occurs when processing the SSID and password of a Wi-Fi direct network.
3. Cannot access NAT connection in quick recovery.
4. Icons do not show up after reconnection.
5. Incorrect user account access rights are sent to the SSDK application.
Other changes:
1. Supports Web application API V1.02.
2. Supports QR code applications
3. The WiFi channel was changed.
4. G1.5 system remote F/W update
1.30 Symptom corrected:
1. Printing from the browser (Smart Operation Panel) fails if the user has signed in with a
multi-byte user ID and password.
2. A user account without access rights to the browser may be displayed inside the
authentication UI customized app as having these access rights ("Authorized for
browsing").
3. An error dialog is displayed and login is not possible if the user tries the login without a
user name.
Other changes:
1. Web application API V1.01
2. Supports business sineage apps for the Smart Operation Panel.
1.29 Error Corrected:
1. Garbled Chinese characters
2. Data-in LED turns is ON when the machine enters Energy Saver mode following a
machine reboot.
3. Data-in LED turns ON when the engine reaches off status if the machine is rebooted
(turned OFF/ON) during a job.
4. The machine does not recover from Energy Saver mode.
5. Translation errors in Russian.
6. Job Stop screen is not displayed when the Stop key is pressed while the user is logged
out of Simple Copy mode.
7. The previous screen appears if the user logs out from the 'linkage failed' screen.
8. Display does not return to Home screen if the Home button is pressed right after the Job
History tab is pressed.
9. Wording errors in several languages were corrected (Cloud FAX).
10. Stop key does not respond while the user is logged out.
11. LUI is displayed when a system reset is performed after completing import/export.
12. Display does not return to the Home screen if the Home key is pressed after the
machine recovers from Sleep mode.
1.28 Other changes:
Added support for using external tools to install applications on the Smart Operation Panel.
1.25 Symptom corrected:
1. Duplicates of the Printer, Scanner, and FAX icons appear when the main power is
turned OFF/ON after the display language is changed.
Other changes:
Technical Bulletin PAGE: 12/12
Reissued: 14-Mar-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/ MET-C1yz_SOP/ Date: 15-Aug-13 No.: RD147150g
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
Version Modified Points or Symptom Corrected
2. The machine hard disk can now be used by applications displayed on the Smart
Operation Panel.
IMPORTANT: To apply this change, update the System/Copy firmware to v3.00
(D1485550K/D1465550L) or later.
1.24 Symptom corrected:
The Smart Operation Panel unit does not reach the Ready condition.
Other changes:
Some words in Portuguese have been revised in accordance with new spelling changes
made to the Portuguese language.
1.22 Symptom corrected:
1. The application icon does not respond after the machine reboots automatically after an
SC.
2. The beep sound can still be heard even when the Warm-up Beeper setting (User Tools)
is turned OFF.
Important:
These firmware changes only apply to the China (CHN) model (only this model is
supported).
1.21 Symptom corrected:
1. The browser displays the page that was last viewed in the previous session if the user
opens the default browser after another has logged out, or after the machine has auto-
reset itself.
2. The display language is changed but the name of the ESA application remains displayed
in the first language.
Important:
The above changes apply only to the CHN model.
1.20 Symptom corrected:
1. Some touch panel coordinates are shifted.
2. The SC screen is not displayed and the Home key does not respond if an SC error
occurs while the status confirmation screen is displayed.
1.19 Symptom corrected:
1. Usernames registered using simplified Chinese characters will appear garbled in the
upper and lower banners after login.
2. Minor bug correction
1.17 1st Mass production
Technical Bulletin PAGE: 1/2
Reissued: 05-Jan-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/MET-C1yz_SOP/ Date: 15-Aug-13 No.: RD147048f
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
RTB Reissue
The items in bold italics have been corrected or added.
Subject: Firmware Release Note: Banner for eDC Prepared by: E. Hinata
From: 1st Tech Service Sect., MFP/Printer Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the Banner for eDC.
Version Program No. Effective Date Availability of RFU
1.13 D1501448H_forEDC November 2016 production Not Available
1.12 D1501448G_forEDC October 2014 production Not Available
1.11 D1501448F_forEDC June 2014 production Not Available
1.10 D1501448E_forEDC March 2014 production Not Available
1.09 D1501448D_forEDC January 2014 production Not Available
1.08 D1501448C_forEDC August 2013 production Not Available
1.07.2 D1501448B_forEDC 1st Mass production Not Available
Note: Definition of Availability of RFU via @Remote
“Available”: The firmware can be updated via RFU or SD card.
“Not available”: The firmware can only be updated via SD card.
Other changes:
Applications for the smart operation panel can be installed, un-installed, and
updated using Remote tools such as DMNX.
1.12 Symptom corrected:
The operational panel display cannot be switched to the FAX screen while the ECO screen
is being displayed.
1.11 Specification change:
Supports the Function Priority setting.
1.10 Error Correction:
Translation errors in Russian were corrected.
Technical Bulletin PAGE: 2/2
Reissued: 05-Jan-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/MET-C1yz_SOP/ Date: 15-Aug-13 No.: RD147048f
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
Version Modified Points or Symptom Corrected
1.09 Symptom corrected:
- Minor bug correction
1.08 Symptom corrected:
The login name is spelled incorrectly if the user logs in using a simplified Chinese user
name.
1.07.2 1st Mass production
Technical Bulletin PAGE: 1/1
Reissued: 05-Jan-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/ MET-C1yz_SOP/ Date: 15-Nov-13 No.: RD147054e
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
RTB Reissue
The items in bold italics have been corrected or added.
Subject: Firmware Release Note: ClockWidget for eDC Prepared by: E. Hinata
From: 1st Tech Service Sect., MFP/Printer Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the ClockWidget
for eDC.
Version Program No. Effective Date Availability of RFU
1.08 D1501453D_forEDC November 2016 production Not Available
1.07 D1501453C_forEDC June 2015 production Not Available
1.06 D1501453B_forEDC Initial release Not Available
This RTB has been issued to announce the firmware release information for the
LanguageWidget for eDC.
Version Program No. Effective Date Availability of RFU
1.11 D1501454C_forEDC November 2016 production Not Available
1.10 D1501454B_forEDC Initial release Not Available
This RTB has been issued to announce the firmware release information for the START_RICOH
for eDC.
Version Program No. Effective Date Availability of RFU
1.26 D1501435D_forEDC November 2016 production Not Available
1.25 D1501435C_forEDC December 2013 production Not Available
1.22 D1501435B_forEDC November 2013 production Not Available
1.17.1 D1501435A_forEDC June 2013 production Not Available
- D1501435_forEDC 1st Mass production Not Available
This RTB has been issued to announce the firmware release information for the ScanToME for
eDC.
Version Program No. Effective Date Availability of RFU
1.11 D1501444E_forEDC November 2016 production Not Available
1.10 D1501444D_forEDC January 2014 production Not Available
1.09 D1501444C_forEDC December 2013 production Not Available
1.08 D1501444B_forEDC Initial release Not Available
Note: Definition of Availability of RFU via @Remote
“Available”: The firmware can be updated via RFU or SD card.
“Not available”: The firmware can only be updated via SD card.
This RTB has been issued to announce the firmware release information for the SimpleFAX for
eDC.
Version Program No. Effective Date Availability of RFU
1.30 D1501447F October 2016 production Not Available
1.29 D1501447E_forEDC July 2016 production Not Available
1.28 D1501447D_forEDC March 2014 production Not Available
1.23 D1501447C_forEDC December 2013 production Not Available
1.11 D1501447B_forEDC Initial release Not Available
RTB Reissue
The items in bold italics have been corrected or added.
Subject: Firmware Release Note: TonnerWidget for eDC Prepared by: E. Hinata
From: 1st Tech Service Sect., MFP/Printer Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the TonnerWidget
for eDC.
Version Program No. Effective Date Availability of RFU
1.08 D1501455C_forEDC November 2016 production Not Available
1.07.1 D1501455B_forEDC Initial release Not Available
This RTB has been issued to announce the firmware release information for the SimpleCopy for
eDC.
Version Program No. Effective Date Availability of RFU
1.19 D1501445K_forEDC January 2017 production Not Available
1.18 D1501445J_forEDC November 2016 production Not Available
1.17 D1501445H_forEDC October 2014 production Not Available
1.16 D1501445G_forEDC June 2014 production Not Available
1.14 D1501445F_forEDC March 2014 production Not Available
1.13 D1501445E_forEDC December 2013 production Not Available
1.12 D1501445D_forEDC November 2013 production Not Available
1.11 D1501445C_forEDC October 2013 production Not Available
1.10 D1501445B_forEDC Initial release Not Available
Note: Definition of Availability of RFU via @Remote
“Available”: The firmware can be updated via RFU or SD card.
“Not available”: The firmware can only be updated via SD card.
Other changes:
2. The specification was changed for the machine's error notification to the Flair API when
the machine is in Simple Copy mode.
1.14 Other changes:
Supports business signage apps for the Smart Operation Panel.
1.13 Other changes:
Some words in Portuguese have been revised in accordance with new spelling changes
made to the Portuguese language.
1.12 Symptom corrected:
Minor bug correction
1.11 Symptom corrected:
[MP C8002/6502 series only]: The replacement alert for the lubricant bar is not displayed at
bar replacement, and the machine cannot perform any jobs.
1.10 Initial release
Technical Bulletin PAGE: 1/2
Reissued: 05-Jan-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/MET-C1yz_SOP/ Date: 14-Feb-14 No.: RD147096i
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
RTB Reissue
The items in bold italics have been corrected or added.
Subject: Firmware Release Note: Web Browser NX for eDC Prepared by: E. Hinata
From: 1st Tech Service Sect., MFP/Printer Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the Web Browser
NX for eDC.
Version Program No. Effective Date Availability of RFU
1.405.0 D1501434J_forEDC November 2016 production Not Available
1.404.0 D1501434H_forEDC September 2016 production Not Available
1.403.0 D1501434G_forEDC September 2015 production Not Available
1.402.0 D1501434F_forEDC May 2015 production Not Available
1.401.0 D1501434E_forEDC October 2014 production Not Available
1.301.0 D1501434D__forEDC October 2014 production Not Available
1.201.0 D1501434C__forEDC June 2014 production Not Available
1.101.0 D1501434B March 2014 production Not Available
1.02.0 D1501434A March 2014 production Not Available
1.01.0 D1501434_forEDC 1st Mass production Not Available
Note: Definition of Availability of RFU via @Remote
“Available”: The firmware can be updated via RFU or SD card.
“Not available”: The firmware can only be updated via SD card.
This RTB has been issued to announce the firmware release information for the
CH1a_QRCodeforSDC for eDC.
This RTB has been issued to announce the firmware release information for the Announce for
eDC.
Version Program No. Effective Date Availability of RFU
1.11 D1501449F_forEDC November 2016 production Not Available
1.10 D1501449E_forEDC October 2014 production Not Available
1.09 D1501449D_forEDC March 2014 production Not Available
1.08.1 D1501449A_forEDC March 2014 production Not Available
1.07.1 D1501449B_forEDC Initial release Not Available
This RTB has been issued to announce the firmware release information for the IWnnIME for
eDC.
Version Program No. Effective Date Availability of RFU
2.1.7 D1501452_forEDC Initial release Not Available
-----------------
Initial release
Technical Bulletin PAGE: 1/2
Reissued: 13-Mar-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/ MET-C1yz_SOP/ Date: 29-Nov-13 No.: RD147060n
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
RTB Reissue
The items in bold italics have been corrected or added.
Subject: Firmware Release Note: LegacyUI Prepared by: E. Hinata
From: 1st Tech Service Sect., MFP/Printer Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the LegacyUI .
Version Program No. Effective Date Availability of RFU
1.31 D1501443T_forEDC March 2017 production Not Available
1.30 D1501443S_forEDC November 2016 production Not Available
1.29 D1501443R_forEDC October 2015 production Not Available
1.28 D1501443Q_forEDC October 2015 production Not Available
1.27 D1501443P_forEDC March 2015 production Not Available
1.26 D1501443N_forEDC October 2014 production Not Available
1.25 D1501443M_forEDC June 2014 production Not Available
1.24 D1501443L_forEDC June 2014 production Not Available
1.23 D1501443K_forEDC April 2014 production Not Available
1.22 D1501443J_forEDC March 2014 production Not Available
1.21 D1501443H_forEDC December 2013 production Not Available
1.19 D1501443F_forEDC October 2013 production Not Available
1.18 D1501443E_forEDC 1st Mass production Not Available
Other changes:
2. Supports the SDK/J application priority setting.
1.24 Symptom corrected:
[Smart Operation Panel only]: The machine may not recover from Energy Saver mode.
1.23 Other changes:
Deleted unnecessary function to print out event logs.
1.22 Symptom collected
The display freezes if the machine is repeatedly put into and then recovered from Energy
Saver mode from the Smart Operation Panel.
1.21 Symptom corrected:
The icon for an SDK application disappears from the display when the machine recovers
from Energy Saver mode.
1.19 Other changes:
A touch screen function was added to the preview screen.
IMPORTANT: To apply the above change, in addition to this firmware, make sure to update
the System/Copy firmware to Ver.2.24 or later and all applications that use this feature to the
supported versions.
1.18 1st Mass production
Technical Bulletin PAGE: 1/2
Reissued: 13-Mar-17
Model: MET-C1ab_SOP/ MET-C1cde_SOP/MET-C1yz_SOP/ Date: 15-Nov-13 No.: RD147069g
Cor-C1_SOP/OR-C2_SOP/Z-C2_SOP
RTB Reissue
The items in bold italics have been added.
Subject: Firmware Release Note: StateInfo for eDC Prepared by: E. Hinata
From: 1st Tech Service Sect., MFP/Printer Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the StateInfo for
eDC.
Version Program No. Effective Date Availability of RFU
1.22 D1501450K_forEDC March 2017 production Not Available
1.21 D1501450J_forEDC November 2016 production Not Available
1.20 D1501450H_forEDC June 2014 production Not Available
1.16 D1501450F_forEDC March 2014 production Not Available
1.13 D1501450E_forEDC January 2014 production Not Available
1.12 D1501450D_forEDC December 2013 production Not Available
1.11 D1501450C_forEDC October 2013 production Not Available
1.10 D1501450B_forEDC Initial release Not Available
This RTB has been issued to announce the firmware release information for the
PersonalizationService for eDC.
Version Program No. Effective Date Availability of RFU
1.30 D1501433C_forEDC November 2016 production Not Available
1.29.1 D1501433B_forEDC March 2014 production Not Available
1.28 D1501433A January 2014 production Not Available
1.25 D1501433_forEDC Initial release Not Available
This RTB has been issued to announce the firmware release information for the iWnnIME_Greek
for eDC.
Version Program No. Effective Date Availability of RFU
2.1.7 D1501436_forEDC Initial release Not Available
-----------------
Spec change:
Supported Greek characteristic IME
Technical Bulletin
Reissued:04-July-19 PAGE: 1/6
Model: Cor-C1 Date: 31-Oct-14 No.: RD197035a
RTB Reissue
The items in bold italics were corrected or added.
Subject: Service Manual Correction (Toner Prepared by: Shunsuke Kuramoto
Replenishment)
From: 2nd Tech Support Sect.,Tech Support Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other () Tier 2
Toner Bottle
This machine has toner bottle set detection and does not operate without the toner
bottle.
D197, D198, and D199 toner bottles are compatible with D200, D201, and D202.
However, D200, D201, and D202 toner bottles are incompatible with D197, D198,
and D199.
1. Open the front cover.
2. Make sure that the black cap of the toner bottle is tightened firmly, then shake
the toner bottle up and down seven or eight times while the cap faces upward.
Shaking the bottle while the cap faces downward causes a possible toner
blockage.
3. Remove the toner bottle protection cap [A].
5. Turn on the main power switch while the front cover is open to execute the initial
toner supply.
If the front cover is closed after turning on the main power switch, the
machine starts a normal toner supply initialization.
6. Tap [System SP] on Copier screen to access the SP mode.
IMPORTANT: Make sure to access the SP mode from the Copier screen.
Initializing messages do not show up if you enter SP mode from the home
screen, so please make sure that you enter SP mode from the copy
window.
7. Set the setting of SP3-510-031 (ImgQltyAdj: ExeFlag: Init Toner Replenish: K) to
“1”, and then press “#” on the operation panel.
Technical Bulletin
Reissued:04-July-19 PAGE: 3/6
Model: Cor-C1 Date: 31-Oct-14 No.: RD197035a
It takes about one to two minutes to finish the initial toner supply. If the toner
has not been shaken well, it may take up to about 10 minutes.
If a toner bottle has not been set, the machine does not work because there is
a toner bottle set detection mechanism.
If you turn on the machine without closing the front cover, the initial toner
supply is not performed at installation, and the machine goes to the toner
end condition even if the machine has plenty of toner in the toner bottle.
If you access the SP mode from the [Home] screen, the initialization
messages mentioned above will appear as banners, not on the entire
display.
11. Enter SP mode again, and then press [System Sp].
12. Enter SP7-622-250 (PM Counter Reset: SCS), and then press [Execute].
14. Enter SP3-011-001 (Manual ProCon :Exe), and then press [Execute].
This RTB has been issued to announce the firmware release information for the SimpleScan for
eDC.
Version Program No. Effective Date Availability of RFU
1.16 D1501446H February 2017 production Not Available
1.15 D1501446G November 2016 production Not Available
1.14 D1501446F July 2016 production Not Available
1.13 D1501446E_forEDC March 2014 production Not Available
1.12 D1501446D_forEDC December 2013 production Not Available
1.11 D1501446C_forEDC November 2013 production Not Available
1.10 D1501446B_forEDC Initial release Not Available
This RTB has been issued to announce the firmware release information for the PS3 Font.
This RTB has been issued to announce the firmware release information for the PCL Font.
This RTB has been issued to announce the firmware release information for the Font EXP.
Reissue: 12-May-15
Model: Cor-C1 Date:12-Dec-14 No.: RD197036a
RTB Reissue
The areas in bold/italics were added or revised.
Subject: Service Manual Correction Prepared by: A.Ishida
From: 2nd Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Specification) Tier 2
5. System Maintenance
SP Mode Tables- SP5000-1 P737
Note:
• When changing the screen in the field (standard panel smart operation panel), perform the
following steps.
• Smart Operation Panel Type M3 is not an option for the EU region. (Standard model)
From Step 2 to Step 13, the replacement procedure of the operation panel is not changed.
14. Download package firmware (D2015506*) for the SOP model from the firmware download
center.
If the SD card is blank, make a "Package" folder on the SD card, and copy the package firmware
there.
15. Insert the SD card into SD Card Slot 2 (Lower Slot) and turn the main switch on.
16. An alert message appears after turning the main switch on due to a difference in the firmware
part numbers, and press the OK button.
17. Select the package file and update the controller firmware version.
18. Turn the main switch off-on, then check to see if the updating is done with the following user
tool: User tool > System Setting > Administrator Setting > Firmware Version)
Technical Bulletin PAGE: 1/1
Model: Cor-C1 Date: No.: RD197038
Subject: Parts Number Corrected Prepared by: A.Ishida
From: 2nd Tech. Service Section, MFP/P Tech. Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier2
Change/Reason: The following part is now provided as a set, and not as an individual
service part.
Note: The new set (P/N D2023028) consists of the three old parts below (D2023225,
D2023224, D2023242 (x2)).
Reissue
Model: Cor-C1c Date: 9-Feb-15 No.: RD197039a
RTB Reissue
The items in bold italics were corrected or added.
7. Insert the Ethernet cable into the Ethernet post on this option.
8. Insert the other end of the Ethernet cable to a PC for network setting.
9. Plug the power cord into the wall socket and turn on the main power of the machine.
Note:
Do not unplug the USB cable while the machine is recognizing this option. It may take
between 30 seconds to 1 minute to finish recognizing it (the LEDs on the Ethernet port of
this option; see below). If unplugged, connect the cable again.
10. Print out the “Configuration Page”, and then check if this option is correctly recognized.
・User tools/Counter >Printer Features >List/Test Page >Configuration Page
10. Do one of the following (a) – (d) to check to see that the option is detected correctly.
10-(a). Access the option’s IP address from a PC browser.
10-(b). Ping the option’s IP address from a command prompt on a Windows PC in the same
network as the Cor-C1.
If IP address cannot be found (DHCP server), use the MAC address. This is the number
printed on the seal affixed to the printed circuit board for the USB server.
Technical Bulletin PAGE: 2/3
Reissue
Model: Cor-C1c Date: 9-Feb-15 No.: RD197039a
10-(c). Use “RX” + the option’s MAC address and access a PC browser.
EX. http://RX0080926A3264
10-(d). Ping the “RX” + “MAC address” from command prompt, windows PC which is in the
same network with Cor-C1.
Note:
・When Installing the USB Device Server Option Type M12, the installation status couldn’t be
shown in Configuration Page.
Technical Bulletin PAGE: 3/3
Reissue
Model: Cor-C1c Date: 9-Feb-15 No.: RD197039a
Notes for Energy Save Mode Setting (pg.134)
If the machine which has this option enters into the energy save mode, you cannot print because
there will be a communication error. Follow the instructions below to disable the machine’s entering
into the energy save mode.
1. Press [Features Settings] on the operation panel.
2. Press [Administrator Tools] in [System Settings].
3. Press [Energy Saver Mode to Disable Print Server].
4. Press [Disable Mode].
5. Press [OK].
6. Press [Features Settings].
Symptom
Smart Operation Panel is sometimes unable to connect to the network when "Screen
Startup Mode" is set to "Quick" (as the default, this setting is set to "Normal"). If Smart
Operation Panel cannot connect to the network, the following applications and functions
cannot work properly:
- Web Browser
- Web Browser NX
- Scan to Me
- Installing an application via the eDC server
Applications that use the network function on the device (GW controller) are not affected,
such as the printer, scanner, and Web Image Monitor.
Occurrence conditions:
When all of the following conditions are met, this issue might occur:
- "Screen Startup Mode" is set to "Quick"
Cause
Smart Operation Panel uses the device's network function via a USB cable between Smart
Operation Panel and the device when it connects to the network. For this communication,
Smart Operation Panel obtains the IP address from the DHCP service on the device's
controller.
Because of the slow booting of the controller, Smart Operation Panel starts obtaining the
IP address before the connection between Smart Operation Panel and the device is
completely established. In addition, the process for retrying to obtaining the IP address
does not work properly. This results in Smart Operation Panel being unable to connect to
the network.
Workaround:
Rebooting the device might solve the problem. The USB connection between Smart
Operation Panel and the device is affected by the timing of when the Android OS
establishes that connection, but the details about the process of establishing the
connection are not clear.
Solution
Update the “CheetahSystem” firmware on the following machines to v1.37 or newer if the
symptom occurs:
- For US, European, and Asian (except for Chinese and Taiwanese) models: D1501457W
- For Chinese and Taiwanese models: D1501440W
Technical Bulletin PAGE: 1/6
Model: Model Cor-C1 Date: 08-Jan-15 No.: RD197040
Important Information on Installing the COR-C1 models (SP models for NA and GSA) as a
CC-CERTIFIED Machine compliant with IEEE Std 2600.2TM-2009
Do the following seven steps if you want to install the COR-C1 models (SP models for NA
and GSA) as a CC-CERTIFIED MACHINE compliant with IEEE Std 2600.2TM-2009.
Note: Machines in production are CC-certified beginning in December 2014.
Important: If the customer requests maintenance on the machine, please perform the
maintenance without accessing SP mode.
1. Make sure the customer has received the English language Operating Instructions (O/I)
shown in the page 6 - 7.
Important:
・Confirm that the URLs written on "Manuals for This Machine" in "Read This First"
are the same as the following URLs:
http://support-download.com/services/device/ccmanual/
mp_2554_3054_3554_4054_5054_6054 /en/download_admin.html
http://support-download.com/services/device/ccmanual/
mp_2554_3054_3554_4054_5054_6054/en/download_user.html
・Tell the customer that those manuals evaluated for CC certification are
the manuals listed in The list of Operating Instructions (O/I).
・Tell the customer to see the Online Document Set 1 from the following URL:
http://support-download.com/services/device/ccmanual/MP2554SP/en/booklist/
int/index_book.htm
・Tell the customer to see the Online Document Set 2 from the following URL:
http://support-download.com/services/device/ccmanual/MP2554SP/en/pdf/User.html
・Tell the customer to see the Online Document Set 3 from the following URL:
http://support-download.com/services/device/ccmanual/MP2554SP/en/pdf/
DriverInstall.html
・Tell the customer to see the Online Document Set 4 from the following URL:
http://support-download.com/services/device/ccmanual/MP2554SP/en/pdf/Oss.html
・Tell the customer to download the Online Document Set 5 (the information about the
authentication based on the CC certification system) from the URLs provided in
"Manuals for This Machine" in "Manuals Provided with This Machine" in "Read
This First".
2. Tell the customer to read the “Notes for Administrators: Using This Machine in a
Network Environment Compliant with IEEE Std 2600.2TM-2009”.
By comparing the ADF and the images in "2. Installation", "ARDF DF3090", "Installation
Procedure" in "Model COR-C1 Machine Code: D197/D198/D199/D200/D201/D202 Field
Service Manual", and by comparing the ADF and the images in "2. Installation", "SPDF
DF3080", "Installation Procedure" in "Model COR-C1 Machine Code:
D197/D198/D199/D200/D201/D202 Field Service Manual", confirm that no suspicious
parts or devices are attached to the ADF cable.
Firmware versions with which the COR-C1 models (SP models for NA and GSA) first
achieved CC-CERTIFICATION:
(December 2014)
Ic Key and Ic Ctlr versions with which the COR-C1 models (SP models for NA and GSA)
first achieved CC-CERTIFICATION:
(December 2014)
Hardware: Version:
Ic Key 01020714
Ic Ctlr 3330
Technical Bulletin PAGE: 5/6
Model: Model Cor-C1 Date: 08-Jan-15 No.: RD197040
<For GSA>
Paper Documents
・D202-7008 MP 2554/3054/3554/4054/
Technical Bulletin PAGE: 6/6
Model: Model Cor-C1 Date: 08-Jan-15 No.: RD197040
5054/6054 series
Read This First
・D202-7051 Notes for Using This Machine Safely
・D202-7058A Notes for Users
・D193-7658 SOFTWARE LICENSE AGREEMENT
・D193-7659 NOTICE TO USERS
This RTB has been issued to announce the firmware release information for the SD card for Fonts
Type D.
Reissued: 20-Apr-15
Model: Cor-C1 Date: 05-Feb-15 No.: RD197041b
RTB Reissue
The items in bold italics were added.
Subject: Troubleshooting for offset issue on Cor-C1 Prepared by: T. Hirakawa
From: 2nd Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual
Paper path Transmit/receive revision
Product Safety Other ( ) Retrofit information
Tier 2
SYMPTOM
Fusing offset occurs at the edge or center of the paper.
Note: The customer may report a strange odor coming from the machine.
CAUSE
The temperature is too low at the edge or center of the paper when the paper enters the
fusing unit.
SOLUTION
If the symptom occurs on Cor-C1f, please apply the following modified
firmware.
Engine/Ver.1.11:03/D2025501E
Reissued: 20-Apr-15
Model: Cor-C1 Date: 05-Feb-15 No.: RD197041b
Technical Bulletin PAGE: 3/5
Reissued: 20-Apr-15
Model: Cor-C1 Date: 05-Feb-15 No.: RD197041b
Workaround A:
Change the paper tray setting (paper thickness setting) in User Tools to match the
actual paper thickness.
User Tools -> Tray paper setting -> page 2 -> Select tray -> Select paper thickness
Workaround B:
Change the paper tray setting in User Tools.
Note: There is no workaround for Thick Paper 4.
Thin paper -> Plain paper
Plain paper -> Mid thick (For g/h models, plain paper -> thick paper 1)
Note: The copy speed will be reduced from 60cpm to 50cpm on the “h” model.
Mid thick -> Thick paper 1
Note: The copy speed will be reduced (See the chart below).
Thick paper 1 -> Thick paper 2
Note: The copy speed will be reduced (See the chart below).
Thick paper 2 -> Thick paper 3
Thick paper 3 -> Thick paper 4
Note: Auto duplex cannot be used (See the chart below).
Postcards: Thick paper 2 -> Thick paper 3
Side effects: The following may occur, depending on the paper thickness.
- Paper curl
- Decreased productivity
Technical Bulletin PAGE: 4/5
Reissued: 20-Apr-15
Model: Cor-C1 Date: 05-Feb-15 No.: RD197041b
Workaround C:
Increase the target fusing temperature by 5 degrees using the following SPs:
SP 1-105-003
SP 1-105-007
SP 1-105-011
SP 1-105-015
If the symptom occurs with 1200 dpi printing, also increase the target temperature
by 5 degrees for these SPs as well:
SP 1-105-107
SP 1-105-137
SP 1-105-111
Side effects: Paper curl may occur.
Workaround D
Change the target temperature using the following SPs as shown below.
SP 1- 105-109: 145 deg -> 150 deg
SP 1- 105-023: 130 deg -> 140 deg
SP 1- 105-027: 135 deg -> 140 deg
SP 1- 105-141: 140 deg -> 145 deg
SP 1- 105-115: 120 deg -> 125 deg (For 1200 dpi mode)
Side effects: Paper curl may occur.
Workaround C’
Increase the target fusing temperature by 5 more degrees using the following SPs:
SP 1-105-003
SP 1-105-007
SP 1-105-011
SP 1-105-015
For 1200 dpi printing:
SP 1-105-107
SP 1-105-137
SP 1-105-111
Side effects: Paper curl may occur.
Technical Bulletin PAGE: 5/5
Reissued: 20-Apr-15
Model: Cor-C1 Date: 05-Feb-15 No.: RD197041b
Workaround D’
Increase the target fusing temperature by 5 more degrees using the following SPs:
SP 1- 105-109: 145 deg -> 150 deg -> 155 deg
SP 1- 105-023: 130 deg -> 140 deg -> 145 deg
SP 1- 105-027: 135 deg -> 140 deg -> 145 deg
SP 1- 105-141: 140 deg -> 145 deg -> 150 deg
SP 1- 105-115: 120 deg -> 125 deg -> 130 deg (For 1200 dpi mode)
Side effects: Paper curl may occur.
CPM information:
Cor-C1c Cor-C1d Cor-C1e Cor-C1f Cor-C1g Cor-C1h
Plain paper 25 30 35 40 50 60
Mid-thick 25 30 35 40 50 50
Thick paper 1 25 28 28 30 30 30
Thick paper 2 18 18 18 18 18 18
Thick paper 3 18 18 18 18 18 18
Thick paper 4 18 18 18 18 18 18
Technical Bulletin PAGE: 1/4
Model: Cor-C1 Date: 19-Feb-15 No.: RD197042
SYMPTOM
・SC121 (HP error) at installation.
CAUSE
The shoe (resin part circled in red) on the second scanner carriage disengages from the
rail, due to shock and/or shaking during machine transport.
Technical Bulletin PAGE: 2/4
Model: Cor-C1 Date: 19-Feb-15 No.: RD197042
SOLUTION
Production line:
Temporary countermeasure
Before shipment, the first carriage will be moved to the new position shown below (the
distance from the left scale to the edge of the carriage was decreased from 53 +/-3mm
to 17 +/-3mm).
Note:
This ensures that the second carriage stays firmly fixed in place. When the first carriage is
in this position, the second carriage is supported by the screw (circled in red).
See Cut-in Serial Numbers below.
Before:
Permanent countermeasure
The shape of the second carriage will be changed so that it does not disengage from the
rail.
Technical Bulletin PAGE: 3/4
Model: Cor-C1 Date: 19-Feb-15 No.: RD197042
In the field:
Do the Procedure below.
PROCEDURE
4. Carefully lift up the second scanner carriage, and then put the shoe back into the rail.
SYMPTOM
The image density decreases with continuous printing, especially in solid image areas
(though it is within specification).
Note: This does not occur in text areas.
CAUSE
This may occur due to the condition of the developer, and also occurs more easily when
repeat prints are made from the same original.
SOLUTION
Change the following SP modes as shown.
Note:
- This will increase the amount of toner used to develop the image.
- As a side effect, this will shorten the yield of the toner bottle.
Important Information on Installing the COR-C1 models (SP models for EU and Asia) as a
CC-CERTIFIED Machine compliant with IEEE Std 2600.2TM-2009
Do the following seven steps if you want to install the COR-C1 models (SP models for EU
and Asia)) as a CC-CERTIFIED MACHINE compliant with IEEE Std 2600.2TM-2009.
Note: Machines in production are CC-certified beginning in March 2015.
Important: If the customer requests maintenance on the machine, please perform the
maintenance without accessing SP mode.
1. Make sure the customer has received the English language Operating Instructions (O/I)
shown in the page 6 - 7.
Important:
・For installations in the EU market, make sure this is the Ricoh-genuine O/I.
・Confirm that the URLs written on "Manuals for This Machine" in "Read This First"
are the same as the following URLs:
http://support-download.com/services/device/ccmanual/
mp_2554_3054_3554_4054_5054_6054 /en/download_admin.html
http://support-download.com/services/device/ccmanual/
mp_2554_3054_3554_4054_5054_6054/en/download_user.html
・Tell the customer that those manuals evaluated for CC certification are
the manuals listed in The list of Operating Instructions (O/I).
・Tell the customer to see the Online Document Set 1 from the following URL:
http://support-download.com/services/device/ccmanual/MP2554SP/en/booklist/
int/index_book.htm
・Tell the customer to see the Online Document Set 2 from the following URL:
http://support-download.com/services/device/ccmanual/MP2554SP/en/pdf/User.html
・Tell the customer to see the Online Document Set 3 from the following URL:
http://support-download.com/services/device/ccmanual/MP2554SP/en/pdf/
DriverInstall.html
・Tell the customer to see the Online Document Set 4 from the following URL:
http://support-download.com/services/device/ccmanual/MP2554SP/en/pdf/Oss.html
・Tell the customer to download the Online Document Set 5 (the information about the
authentication based on the CC certification system) from the URLs provided in
"Manuals for This Machine" in "Manuals Provided with This Machine" in "Read
This First".
2. Tell the customer to read the “Notes for Administrators: Using This Machine in a
Network Environment Compliant with IEEE Std 2600.2TM-2009”.
See the following pages for Step 3 to Step 7.
Technical Bulletin PAGE: 2/6
Model: Model Cor-C1 Date: 23-Mar-15 No.: RD197044
By comparing the ADF and the images in "2. Installation", "ARDF DF3090", "Installation
Procedure" in "Model COR-C1 Machine Code: D197/D198/D199/D200/D201/D202 Field
Service Manual", and by comparing the ADF and the images in "2. Installation", "SPDF
DF3080", "Installation Procedure" in "Model COR-C1 Machine Code:
D197/D198/D199/D200/D201/D202 Field Service Manual", confirm that no suspicious
parts or devices are attached to the ADF cable.
Firmware versions with which the COR-C1 models (SP models for EU and Asia)) first
achieved CC-CERTIFICATION:
(March 2015)
Ic Key and Ic Ctlr versions with which the COR-C1 models (SP models for EU and Asia))
first achieved CC-CERTIFICATION:
(March 2015)
Hardware: Version:
Ic Key 01020714
Ic Hdd 3330
Technical Bulletin PAGE: 5/6
Model: Model Cor-C1 Date: 23-Mar-15 No.: RD197044
<For Asia>
Paper Documents
・D202-7009 MP 2554/3054/3554/4054/
5054/6054 series
Read This First
・D202-7150 Notes for Using This Machine Safely
・D202-7058A Notes for Users
・D193-7658 SOFTWARE LICENSE AGREEMENT
・D193-7659 NOTICE TO USERS
SYMPTOM
The bracket for the handset kit (Handset HS3020) used on the Cor-C1, Met-C1, and Or-C2
cannot be installed on the Cor-C1.
CAUSE
The screw used to attach the handset is too small compared to the screw hole in the
cover.
SOLUTION
Temporary countermeasure:
Install the modified handset kit (P/N D1979900). The size of the screw hole in the bracket
was changed to fit the M4 screws.
Note: The handset kits that contain the modified bracket have a green seal affixed to the
top of the box.
Technical Bulletin PAGE: 2/2
Model: Cor-C1 Date: 9-Apr-15 No.: RD197045
Permanent countermeasure:
The EDP code of the handset kit will changed from 416683 to 417548.
Affected machines
The destination for all affected machines is LA.
Appendices:
Page Contents
p.57
Add/Delete:
Mainframe: D197/D198/D199
Apply lubrication
as needed. When
the oil runs out, a
squeaking noise
may occur.
- C/I/L - - -
Technical Bulletin PAGE: 2/2
Model: Cor-C1 Date: 17-Apr-15 No.: RD197047
Mainframe: D200/D201/D202
Apply lubrication
as needed. When
the oil runs out, a
squeaking noise
may occur.
Technical Bulletin PAGE: 1/4
Reissued: 25-Jun-19
Model: Cor-C1.5cdefgh Date: 11-Mar-19 No.: RD284048b
RTB Reissue
The items in bold italics were corrected or added.
Subject: Jam 63 (SPDF DF3120/ 3100/3080) Prepared by: T.Kiyohara
From: MFP section, OPOS Product Quality managemt Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2
SYMPTOM
A paper non-feed (multi-feed and/or Jam 63) occurs.
Affected models:
MET-C2.1abcdeyz (D0AC/D0AD/D0AE/D0AF/D0AG/D0AH/D0AJ)
MET-C2abcdeyz (D238/D239/D240/D241/D242/D243/D244)
COR-C1.5cdefgh (D284/D285/D286/D287/D288/D289)
CAUSE
Paper dust and toner attaches to the reverse roller. If the attraction strength between
sheets of paper is too large, the ability of the paper to separate is decreased.
SOLUTION
If the symptom occurs, do the following:
Note: This will suppress the slight rotation of the reverse roller that is generated when the paper
feed motor is stopped.
2. If this does not solve the issue, replace the separation pad with the following one,
which has been customized specifically for this symptom.
IMPORTANT: Only install this part if the firmware upgrade does not work. This is
because there are side effects with this part (explained below).
Technical Bulletin PAGE: 2/4
Reissued: 25-Jun-19
Model: Cor-C1.5cdefgh Date: 11-Mar-19 No.: RD284048b
2.
[A]
Technical Bulletin PAGE: 3/4
Reissued: 25-Jun-19
Model: Cor-C1.5cdefgh Date: 11-Mar-19 No.: RD284048b
PROCEDURE
1. Remove the separate unit.
Reissued: 25-Jun-19
Model: Cor-C1.5cdefgh Date: 11-Mar-19 No.: RD284048b
This RTB has been issued to announce the firmware release information for the Option IPDS.
Subject: Service Manual Correction(USB Device Server Option Prepared by: Y.Saitoh
Type M12)
From: 1st Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2
Page Contents
p.342
Notes for Energy Save Mode Setting
If the machine which has this option enters into the energy save mode, you
cannot print because there will be a communication error. Follow the
instructions below to disable the machine’s entering into the energy save
mode.
1. Set SP5-191-001 (Power Str Set) to a value of “0”.
2. Exit SP mode.
3. Turn the machine main power OFF/ON.
Technical Bulletin PAGE: 1/2
Model: Cor-C1 Date: 25-May-15 No.: RD197052
Subject: Parts Catalog Correction for Guide Plate for Fusing Prepared by: T. Tachibana
Exit
From: 1st Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2
Change: Ribs were added to the fusing unit guide plate and a retaining ring was added.
Reason: To further strengthen the guide plate and prevent it from breaking.
See IMPORTANT NOTE on next page regarding the attachment of the retaining ring.
Old part New part Description Q’ty Int Page Index Note
number number
08050106 RETAINING RINGS- 0-1 Set
E:SILENCER:DIA6 as
AA061215 AA066435 SPRING:RELEASE:FUSING 1-1 X/X X/O
EXIT
D2024214 D2024215 GUIDE PLATE:FUSING EXIT 1-1 X/X
Attach the retaining ring on the left side of the spring, as shown.
CORRECT: Incorrect:
Technical Bulletin PAGE: 1/2
Reissued: 07-Jul-15
Model: Z-C2_SOP/ OR-C2_SOP/ Cor-C1_SOP/ Date: 27-Mar-15 No.: RD193046b
MET-C1ab_SOP/ MET-C1cde_SOP/MET-C1yz_SOP
RTB Reissue
The items in bold italics have been corrected or added.
Subject: Firmware Release Note: SCANTOFOLDERHELPER Prepared by: Y. Fukuzaki
From: Connectivity Support Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the
SCANTOFOLDERHELPER.
Version Program No. Effective Date Availability of RFU
1.2 D1505532B June 2015 production Not Available
1.1 D1505532B Initial release Not Available
Note: Definition of Availability of RFU via @Remote
“Available” The firmware can be updated via RFU or SD card.
“Not available”: The firmware can only be updated via SD card.
- System/copy:
Model Met-C1 ab v3.11 or later (D1465550X)
Model Met-C1 cde v3.12 or later (D1485550Y)
Model Met-C1 xyz v2.11 or later (D1765550N)
Model Cor-C1 v1.11 or later (D2025550M)
Model Z-C2 v1.07 or later (D1935771G)
Model OR-C2 v1.14 or later (D1835530K)
- CheetahSystem:
v1.39 or later (D1501440Y)
- SDKService:
v1.06.01 or later (D1501437F)
1.1 Initial release
Technical Bulletin PAGE: 1/2
Reissued: 07-Jul-15
Model: Z-C2_SOP/ OR-C2_SOP/ Cor-C1_SOP/ Date: 27-Mar-15 No.: RD193047b
MET-C1ab_SOP/ MET-C1cde_SOP/MET-C1yz_SOP
RTB Reissue
The items in bold italics have been corrected or added.
Subject: Firmware Release Note: IDCARDCOPY Prepared by: Y. Fukuzaki
From: Connectivity Support Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the
IDCARDCOPY.
Version Program No. Effective Date Availability of RFU
1.2 D1505531A June 2015 production Not Available
1.1 D1505531A Initial release Not Available
Note: Definition of Availability of RFU via @Remote
“Available” The firmware can be updated via RFU or SD card.
“Not available”: The firmware can only be updated via SD card.
2. When the "Stop" key is pressed after scanning only one side of a
document and then "Continue Printing" is selected, the following
problems occur:
- An error message for Quick Copy will be displayed above the
screen.
Technical Bulletin PAGE: 2/2
Reissued: 07-Jul-15
Model: Z-C2_SOP/ OR-C2_SOP/ Cor-C1_SOP/ Date: 27-Mar-15 No.: RD193047b
MET-C1ab_SOP/ MET-C1cde_SOP/MET-C1yz_SOP
- CheetahSystem:
v1.39 or later (D1501440Y)
- SDKService:
v1.06.01 or later (D1501437F)
1.1 Initial release
Technical Bulletin PAGE: 1/1
Model: Cor-C1 Date: 25-May-15 No.: RD197050
Subject: FSM correction (USB Device Server Option Type Prepared by: T. Tachibana
M12)
From: 1st Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2
Installation Procedure
When installing this option in North America only:
6-1. Bind both cores with two bands [A], as shown below.
Note: The two binds are not included in options produced before March, 2015. To bind the
cores, use the binds (P/N: 11050047) registered as service parts or similar ones.
Technical Bulletin PAGE: 1/4
Reissued: 3-June-15
Model: Cor-C1c Date: 28-May-15 No.: RD197053a
RTB Reissue
Subject: Troubleshooting for SC721-70 Prepared by: T.Hirakawa
From: 2nd Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2
SYMPTOM
SC721 (Tray Lift Motor Error) occurs on the SR3140/SR3150 finisher.
CAUSE
There is a difference in level on the frame of the side plate tray. If the screw is tightened
too tightly, the side plate may deform.
SOLUTION
Attach the sheet (P/N: D6833644) between the frame and the side plate in the areas
circled.
Reissued: 3-June-15
Model: Cor-C1c Date: 28-May-15 No.: RD197053a
Installation Procedure
1. Remove the finisher.
2. Access the tray upper motor.
SR3140
Access the tray upper motor in the area circled in red (from underneath).
SR3150
Pull the booklet staple unit to access the motor.
Technical Bulletin PAGE: 3/4
Reissued: 3-June-15
Model: Cor-C1c Date: 28-May-15 No.: RD197053a
3. Remove the snap ring
4. Shift the drive gear to the side (in the direction of the red arrow) while holding the up-
and-down frame.
Reissued: 3-June-15
Model: Cor-C1c Date: 28-May-15 No.: RD197053a
6. Attach the sheets to each base frame.
SYMPTOM
Noise may occur in the paper exit unit.
CAUSE
Friction between the inner face of the exit driven roller and roller shaft.
SOLUTION
Apply Silicone Grease G-501(P/N: 52039502) to the roller (P/N: D1494459).
See Procedure below.
Technical Bulletin PAGE: 2/4
Model: Cor-C1c Date: 16-Jun-15 No.: RD197054
Procedure for applying grease to the exit driven rollers
4. Remove the sensor connector and harness from the guide plate.
SYMPTOM
SC672-11 or -12 (Controller start up error) occurs.
SC672-11: Communication error between operation panel and CTL after the machine is powered up.
SC672-12: Communication error between operation panel and CTL after normal start-up.
Note:
- SC672 does not appear on the SMC report, because it is not logged.
- The operation panel (Normal Operation Panel / Smart Operation Panel) communicates with the
controller via a USB cable and the IPU. SC672 is triggered when the panel cannot communicate with
the controller.
- Applicable models: MP 2554/3054/3554/4054/5054/6054
CAUSE
Possible causes include:
1. Failure of USB communication path (USB cable, IPU)
2. Data corruption of CTL onboard Flash memory
3. Poor supply voltage for CTL onboard ASIC
4. Firmware bug related to the energy saving system
5. Defective CTL onboard converter
6. Defective CTL onboard resistors
7. FCU start-up error
IPU Controller
USB
Operation panel
FCU
Figure 1: Operation panel, IPU and Controller / FCU
Technical Bulletin PAGE: 2/11
Model: Cor-C1c Date: 22-Jun-15 No.: RD197055
SOLUTION
In the field:
Do the following.
1. Turn the machine power OFF/ON.
2. Check the power saving system firmware version.
If this firmware is older than ver. F.23 update it to ver. F.23 or newer.
3. Re-connect the USB cable between IPU board and operation panel.
4. Do the action in the flowchart on the next page to determine the cause and best course of
action.
Parts needed:
- USB cable
- CTL board
- IPU board
- FCU board
- Operation panel
Technical Bulletin PAGE: 3/11
Model: Cor-C1c Date: 22-Jun-15 No.: RD197055
Important: If the SC recurs after you do the action in this flowchart, do the following.
- If SC819 (cache error) appears in the SC history, replace the controller board.
- If SC991 (SCS: scs time count level c’) appears in the SC history, replace the controller
board and the USB cable.
Flowchart to determine the replacement parts
Important: When you re-attach the ARDF later, make sure to attach the right hinge
screw on the left side.
15. Remove the USB cable connector [A] (screws x1, clamps x2)
Important:
Never loosen or remove the following screw when you remove or re-attach the unit. This is
because this screw fixes the scanner cam in place. If the position of the scanner cam
changes, the scanner will be misaligned. This will result in image skew and other image
alignment issues.
Important
Make sure that there is no space between the machine frame and the following three areas of
the scanner unit when you re-attach the scanner unit.
Mass-production:
The following modifications were applied for each possible cause.
Subject: FSM correction for SC990, 991, 997 Prepared by: T. Tachibana
From: 1st Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2
6. Troubleshooting
- SC Tables: SC9xx (Others)
SC No. Level Error Name/Error Condition/Major Cause/Solution
Software operation error
Software attempted an unexpected operation.
Parameter error
Internal parameter error
SC990-00 D Insufficient work memory
Operation error caused by abnormalities that are normally
undetectable.
Turn the main power off/on.
Reinstall the software of the controller and BCU board.
Subject: Parts information for Tray Heater Accessory Prepared by: T. Tachibana
From: 1st Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2
Note:
This part is used on the NA, EU, AA, TWN and CHN models.
D2150502 consists of the following parts:
Field Service Manual
- 2. Installation
- Anti-Condensation Heater for Trays
- Accessory Check
Technical Bulletin PAGE: 1/2
Model: Z-C2_SOP/ OR-C2_SOP/ Cor-C1_SOP/ Date: 07-Jul-15 No.: RD193049
MET-C1ab_SOP/ MET-C1cde_SOP/MET-C1yz_SOP
This RTB has been issued to announce the firmware release information for the
CONFERENCECONCIERGE.
Version Program No. Effective Date Availability of RFU
1.1 D1505530B June 2015 production Not Available
Note: Definition of Availability of RFU via @Remote
“Available” The firmware can be updated via RFU or SD card.
“Not available”: The firmware can only be updated via SD card.
2. If the document is set as landscape even though there is no tray that is set to
A4 landscape, Conference Concierge might not be able to staple the upper-
left side.
- CheetahSystem:
v1.39 or later (D1501440Y)
- SDKService:
v1.06.01 or later (D1501437F)
Technical Bulletin PAGE: 1/1
Model: Cor-C1 Date: 28-Jul-15 No.: RD197058
Subject: FSM correction for SP4013 (Scanner Free Run) Prepared by: T. Tachibana
From: 1st Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2
5. System Maintenance
- SP Mode Tables - SP4000
- SP4-XXX (Scanner)
[Scanner Free Run]
4013
SYMPTOM
SC547-02 (Zero cross Error (relay contact fault)) occurs.
CAUSE
The relay harness was mistakenly routed between the air duct and the frame on
the production line.
SOLUTION
If this SC occurs, do the PROCEDURE on the following page.
Technical Bulletin PAGE: 2/7
Model: Cor-C1 Date: 9-Sep-15 No.: RD197059
PROCEDURE
Rear side
8. Check whether or not the relay harness (circled in red) is caught between the
air duct and frame.
If it is, replace all parts shown in the table below.
IMPORTANT: See How to replace the relay harness below.
If it is not, do the action in the Service Manual, SP tables, pg.1114.
C/D/E models:
Part number Description
D1995322 HARNESS:POWER SUPPLY UNIT:POWER SOURCE:FAN
AZ230282 (NA/TWN) POWER SUPPLY UNIT:NA:166W
AZ230284 (EU/AA/KOR) POWER SUPPLY UNIT:EU/AP:166W
AZ230286 (CHN) POWER SUPPLY UNIT:CO-C1E:CHN
D2025106 PCB:BCU:CRN-C1:SRD:ASS'Y
F/G/H models:
Part number Description
D2025322 HARNESS:POWER SUPPLY UNIT:POWER SOURCE:FAN:FGH
AZ230276 (NA/TWN) POWER SUPPLY UNIT:NA:249.7W
AZ230278 (EU/AA/KOR) POWER SUPPLY UNIT:EU/AP
AZ230280 (CHN) POWER SUPPLY UNIT:CO-C1H:CHN
D2025106 PCB:BCU:CRN-C1:SRD:ASS'Y
Technical Bulletin PAGE: 4/7
Model: Cor-C1 Date: 9-Sep-15 No.: RD197059
Left side
Left side
Technical Bulletin PAGE: 5/7
Model: Cor-C1 Date: 9-Sep-15 No.: RD197059
Rear side
5. Disconnect the connector for the relay harness (circled in red) and then
replace the harness.
EU
Model code Serial number
D249-67 G144PC08001 - G145P500368
D250-27 G155P200489 - G155P500841
D251-67 G164PC08001 - G165P500133
CHINA
Model code Serial number
D197-61 G144PB00001 - G145P500174
D197-62 G144PA00002 - G145P401260
Technical Bulletin PAGE: 7/7
Model: Cor-C1 Date: 9-Sep-15 No.: RD197059
NEVER touch the areas outlined in red in the photos below, to prevent electric shock
caused by residual charge.
Residual charge of about 100V-400V remains on the PSU board for several months
even when the board has been removed from the machine after turning off the machine
power and unplugging the power cord.
The procedure to discharge residual charge from the machine by unplugging the power
cord from the AC wall outlet and pressing the main power switch works only for the DC
circuits on this board. Residual charge remains in the AC circuits.
For NA/TWN:
Front: Back:
For EU/AA/CHN:
Front: Back:
Technical Bulletin PAGE: 1/4
Reissued:30-Jan-19
Model: Cor-C1 Date: 4-Nov-15 No.: RD197061a
RTB Reissue
The items in red is the latest one.
Subject: List of controller boards by model and Prepared by: R. Tsurumi
product destination
From: 2nd Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2
This bulletin provides the p/n and description of Controller Boards by model and
product destination.
Updated on 30th Jan 2019:
This bulletin is regarding the new numbers given to the parts. The parts number listed in
red is the latest one.
NA
SP model (Non-SOP) SOP Model
Code P/N Description P/N Description
D197 D1975673 PCB:CTL_JL2:CRN-C1C:EXP D1975676 PCB:CTL_JL2:CRN-C1C_CH:EXP
D2025640 D2005600
D198 D1985673 PCB:CTL_JL2:CRN-C1D:EXP D1985676 PCB:CTL_JL2:CRN-C1D_CH:EXP
D2005641 D2005601
D199 D1995673 PCB:CTL_JL2:CRN-C1E:EXP D1995676 PCB:CTL_JL2:CRN-C1E_CH:EXP
D2005642 D2005602
D200 D2005663 PCB:CTL_JL2:CRN-C1F:EXP D2005676 PCB:CTL_JL2:CRN-C1F_CH:EXP
D2005673 D2005603
D201 D2015673 PCB:CTL_JL2:CRN-C1G:EXP D2015676 PCB:CTL_JL2:CRN-C1G_CH:EXP
D2005644 D2005604
D202 D2025653 PCB:CTL_JL2:CRN-C1H:EXP D2025676 PCB:CTL_JL2:CRN-C1H_CH:EXP
D2005645 D2005605
EU
Non-SOP Model
Basic model SP model
Code P/N Description P/N Description
Technical Bulletin PAGE: 2/4
Reissued:30-Jan-19
Model: Cor-C1 Date: 4-Nov-15 No.: RD197061a
D197 - - D1975673 PCB:CTL_JL2:CRN-C1C:EXP
D2005640
D198 D1985672 PCB:CTL_JL2:CRN-C1D_BASIC:EXP D1985673 PCB:CTL_JL2:CRN-C1D:EXP
D2005651 D2005641
D199 - - D1995673 PCB:CTL_JL2:CRN-C1E:EXP
D2005642
D200 - - D2005663 PCB:CTL_JL2:CRN-C1F:EXP
D2005673
D201 - - D2015673 PCB:CTL_JL2:CRN-C1G:EXP
D2005644
D202 - - D2025653 PCB:CTL_JL2:CRN-C1H:EXP
D2005645
SOP Model
Code P/N Description
D197 D1975676 PCB:CTL_JL2:CRN-C1C_CH:EXP
D2005600
D198 D1985676 PCB:CTL_JL2:CRN-C1D_CH:EXP
D2005601
D199 D1995676 PCB:CTL_JL2:CRN-C1E_CH:EXP
D2005602
D200 D2005666 PCB:CTL_JL2:CRN-C1F_CH:EXP
D2005666
D201 D2015676 PCB:CTL_JL2:CRN-C1G_CH:EXP
D2005604
D202 D2025676 PCB:CTL_JL2:CRN-C1H_CH:EXP
D2005605
AA/TWN
Non-SOP Model
Basic model SP model
Code P/N Description P/N Description
D197 - - D1975673 PCB:CTL_JL2:CRN-C1C:EXP
D2005640
D198 D1985672 PCB:CTL_JL2:CRN-C1D_BASIC:EXP D1985673 PCB:CTL_JL2:CRN-C1D:EXP
Technical Bulletin PAGE: 3/4
Reissued:30-Jan-19
Model: Cor-C1 Date: 4-Nov-15 No.: RD197061a
D2005651 D2005641
D199 D1995672 PCB:CTL_JL2:CRN-C1E_BASIC:EXP D1995673 PCB:CTL_JL2:CRN-C1E:EXP
D2005652 D2005642
D200 D2005672 PCB:CTL_JL2:CRN-C1F_BASIC:EXP D2005663 PCB:CTL_JL2:CRN-C1F:EXP
D2005653 D2005673
D201 D2015672 PCB:CTL_JL2:CRN-C1G_BASIC:EXP D2015673 PCB:CTL_JL2:CRN-C1G:EXP
D2005654 D2005644
D202 D2025662 PCB:CTL_JL2:CRN-C1H_BASIC:EXP D2025653 PCB:CTL_JL2:CRN-C1H:EXP
D2025652 D2005645
SOP Model
Basic model SP model
This parts needed when install SOP to Basic
model.
Code P/N Description P/N Description
D197 - - D1975676 PCB:CTL_JL2:CRN-C1C_CH:EXP
D2005600
D198 D1985675 PCB:CTL_JL2:CRN-C1D_BAS_CH:EXP D1985676 PCB:CTL_JL2:CRN-C1D_CH:EXP
D2005611 D2005601
D199 D1995675 PCB:CTL_JL2:CRN-C1E_BAS_CH:EXP D1995676 PCB:CTL_JL2:CRN-C1E_CH:EXP
D2005612 D2005602
D200 D2005665 PCB:CTL_JL2:CRN-C1F_BAS_CH:EXP D2005666 PCB:CTL_JL2:CRN-C1F_CH:EXP
D2005675 D2005676
D201 D2015675 PCB:CTL_JL2:CRN-C1G_BAS_CH:EXP D2015676 PCB:CTL_JL2:CRN-C1G_CH:EXP
D2005614 D2005604
D202 D2025685 PCB:CTL_JL2:CRN-C1H_BAS_CH:EXP D2025676 PCB:CTL_JL2:CRN-C1H_CH:EXP
D2005620 D2005605
CHN
Non-SOP Model
Basic model SP model
Code P/N Description P/N Description
D197 - - D1975673 PCB:CTL_JL2:CRN-C1C:EXP
D2005640
D198 - - D1985673 PCB:CTL_JL2:CRN-C1D:EXP
D2005641
Technical Bulletin PAGE: 4/4
Reissued:30-Jan-19
Model: Cor-C1 Date: 4-Nov-15 No.: RD197061a
D199 - - D1995673 PCB:CTL_JL2:CRN-C1E:EXP
D2005642
D200 D2005672 PCB:CTL_JL2:CRN-C1F_BASIC:EXP D2005663 PCB:CTL_JL2:CRN-C1F:EXP
D2005653 D2005673
D201 D2015672 PCB:CTL_JL2:CRN-C1G_BASIC:EXP D2015673 PCB:CTL_JL2:CRN-C1G:EXP
D2005654 D2005644
D202 D2025662 PCB:CTL_JL2:CRN-C1H_BASIC:EXP D2025653 PCB:CTL_JL2:CRN-C1H:EXP
D2025652 D2005645
SOP Model
Basic model SP model
This parts needed when install SOP to Basic
model.
Code P/N Description P/N Description
D197 - - D1975676 PCB:CTL_JL2:CRN-C1C_CH:EXP
D2005600
D198 - - D1985676 PCB:CTL_JL2:CRN-C1D_CH:EXP
D2005601
D199 - - D1995676 PCB:CTL_JL2:CRN-C1E_CH:EXP
D2005602
D200 D2005665 PCB:CTL_JL2:CRN-C1F_BAS_CH:EXP D2005666 PCB:CTL_JL2:CRN-C1F_CH:EXP
D2005675 D2005676
D201 D2015675 PCB:CTL_JL2:CRN-C1G_BAS_CH:EXP D2015676 PCB:CTL_JL2:CRN-C1G_CH:EXP
D2005614 D2005604
D202 D2025685 PCB:CTL_JL2:CRN-C1H_BAS_CH:EXP D2025676 PCB:CTL_JL2:CRN-C1H_CH:EXP
D2005620 D2005605
Technical Bulletin PAGE: 1/2
Reissued: 9-May-16
Model: Cor-C1 Date: 5-Nov-16 No.: RD197062b
RTB Reissue
The items in bold italics were corrected.
Subject: Supplementary information on the optional anti-condensation Prepared by: A Ishida
heater
From: 1st Tech. Support Sec. Service Support Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2 Tier 0.5
4 types of anti-condensation heaters are available as service parts for the following
components:
- Mainframe tray
- Optional tray (PB3150, PB3220/PB3210, PB3230/PB3170)
- PCU
- Scanner
See the table below for the parts required when installing the heater.
Scanner Heater
+ PCU heater
+ PCU heater
PCU Heater
Reissued: 9-May-16
Model: Cor-C1 Date: 5-Nov-16 No.: RD197062b
RTB Reissue
The items in bold italics were corrected.
Assembly-1: Heater PCB is composed of the following parts.
Part number Description Q’ty
D2025185 PCB:DHB 1
D2025396 HARNESS:BCU:DEHUMIDIFIER:DC 1
D2025397 HARNESS:POWER SUPPLY UNIT: 1
DEHUMIDIFIER:AC
D2025398 HARNESS:DEHUMIDIFIER:PAPER FEED:BANK 1
04543006Q TAPPING SCREW - M3X6 3
11050758 CLAMP:LWSM-0306A 7
11050763 CLAMP:LWS-1211A 1
IMPORTANT:
Make sure to install the tray heater with the rated voltage that matches your
country/region.
If you do not, the heater will overheat and damage the tray and/or cause
carbonization (Example: If a 100V heater is installed on a 200V rated machine), or
the heater will not be able to reduce enough moisture (Example: If a 200V heater is
installed on a 100V rated machine).
Technical Bulletin PAGE: 1/2
Model: Cor-C1 Date: 13-Nov-15 No.: RD197063
Subject: Request for mylar replacement when installing the Document Prepared by: T. Tachibana
Feeder DF3090
From: 1st Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Request at Tier 2 Tier 0.5
installation)
Request
When installing the Document Feeder (DF3090), replace the mylar originally attached to
its exposure glass with the new mylar included as an accessory to the Document Feeder.
Scan quality, especially at the trailing edge of the original, is better with the new mylar.
Replace the mylar for the following combination of the mainframe and DF3090:
- DF3090 manufactured from October 2015 and main unit manufactured before
October 2015 production.
S/N information
Main unit Document Feeder (DF3090)
Before October 2015 production From October 2015 production
e.g.
G145f9xxxxx, G145f8xxxxx,
G155f9xxxxx, G155f8xxxxx,
E935fAxxxxx,
G165f9xxxxx, G165f8xxxxx,
E935fBxxxxx,
G175f9xxxxx, G175f8xxxxx,
E935fCxxxxx,
G185f9xxxxx, G185f8xxxxx,
G195f9xxxxx, G195f8xxxxx,
e.g. G14yfmxxxxx
y: Right most digit of the year of production
m: Production month
Technical Bulletin PAGE: 2/2
Model: Cor-C1 Date: 13-Nov-15 No.: RD197063
Mylar Replacement Procedure:
Note:
- If the mylar could not be attached properly, remove it and attach a new one at your
next visit.
- Without the new mylar, feeding thick paper for more than 90K pages may cause
jitter.
1. Remove the mylar originally attached from the document feeder exposure glass.
2. Wipe the document feeder exposure glass with cloth.
3. Attach the new mylar.
- The cutout on the mylar faces to the left.
- Set the top left corner (circled in red) flush against the top edge of the exposure glass.
0~0.5 mm
0~0.5 mm
Cutout
Part Information:
Part number Description Q’ty
D2411727 SHEET:GAP:ASS'Y 1
Technical Bulletin PAGE: 1/10
Model: Cor-C1 Date: 30-Nov-15 No.: RD197064
SC302-00 to SC392-01
Motor defective
Connector disconnected
Harness broken
IOB BCU defective.
Unit torque increased
Motor defective
Connector disconnected
Harness broken
IOB BCU defective
PCU torque increased
Technical Bulletin PAGE: 2/10
Model: Cor-C1 Date: 30-Nov-15 No.: RD197064
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC440-00 to SC498-00
Hardware error
Input / Output connector is disconnected.
Input / Output harness is short-circuited.
IOB BCU error (signal error)
HVPS defective
Load error
Transfer roller's impedance increases.
Transfer unit is not set properly.
Hardware error
Input / Output connector is disconnected.
Input / Output harness is short-circuited.
Transfer unit is not set properly.
IOB BCU error (signal error)
HVPS defective
Load error
Grounding fault of separation power output, short-circuit
with other outputs
Surface/air clearance insufficient in separation power
output path (including distance from other outputs)
SC501-01 to SC589-02
The machine detects the error of the 1st tray lift motor 3 times
consecutively when the 1st tray is lifted.
(The message of resetting the tray is displayed when the
machine detects the error consecutively 2 times or less.)
The machine detects the error of the 1st tray lift motor 5 times
consecutively when the 1st tray is lowered.
(The message of resetting the tray is displayed when the
machine detects the error consecutively 4 times or less.)
The machine detects the error of the 2nd tray lift motor 3 times
consecutively when the 2nd tray is lifted.
(The message of resetting the tray is displayed when the
machine detects the error consecutively 2 times or less.)
The machine detects the error of the 2nd tray lift motor 5 times
consecutively when the 2nd tray is lowered.
(The message of resetting the tray is displayed when the
machine detects the error consecutively 4 times or less.)
Motor defective
Connector disconnected
Harness broken
IOB BCU defective
Encoder defective
Motor defective
Connector disconnected
Harness broken
IOB BCU defective
Encoder defective
Motor defective
Connector disconnected
Harness broken
IOB BCU defective
Encoder defective
Motor defective
Connector disconnected
Harness broken
IOB BCU defective
Motor defective
Connector disconnected
Harness broken
IOB BCU defective
Motor defective
Connector disconnected
Harness broken
IOB BCU defective
Motor defective
Connector disconnected
Harness broken
IOB BCU defective
Technical Bulletin PAGE: 8/10
Model: Cor-C1 Date: 30-Nov-15 No.: RD197064
SC No. Level Error Name/Error Condition/Major Cause/Solution
Motor defective
Connector disconnected
Harness broken
IOB BCU defective
During motor ON, after checking lock signals for 2sec, a High
level was detected at least 20 times.
Motor defective
Connector disconnected
Harness broken
IOB BCU defective
Unit torque increased
Triac short-circuit
IOB board defective
BCU board defective
Triac short-circuit
IOB defective
BCU defective
Triac short-circuit
IOB defective
BCU defective
Triac short-circuit
IOB defective
BCU defective
Technical Bulletin PAGE: 10/10
Model: Cor-C1 Date: 30-Nov-15 No.: RD197064
SC No. Level Error Name/Error Condition/Major Cause/Solution
SP6-XXX (Peripherals)
If you install the COR-C1 model (for NA, GSA, Asia, EU and KOR), please follow this RTB
instead of RTB No.RD197040 (for NA, GSA), No.RD197044 (for EU and Asia).
Because the firmware has been updated.
Do the following seven steps if you want to install the COR-C1 models (SP models) as a
CC-CERTIFIED MACHINE compliant with IEEE Std 2600.2TM-2009.
Note: Machines in production are CC-certified beginning in October 2015.
Important: If the customer requests maintenance on the machine, please perform the
maintenance without accessing SP mode.
1. Make sure the customer has received the English language Operating Instructions (O/I)
shown in the page 6 -11.
Important:
・For installations in the EU market, make sure this is the Ricoh-genuine O/I.
・Confirm that the URLs written on "Manuals for This Machine" in "Read This First"
are the same as the following URLs:
http://support-
download.com/services/device/ccmanual/mp_2554_3054_3554_4054_5054_6054/en/
download_admin.html
http://support-
download.com/services/device/ccmanual/mp_2554_3054_3554_4054_5054_6054/en/
download_user.html
・Tell the customer that those manuals evaluated for CC certification are
the manuals listed in The list of Operating Instructions (O/I).
・Tell the customer to see the Online Document Set 1 from the following URL:
http://support-download.com/services/device/ccmanual/MP2554SP/en/booklist/
int/index_book.htm
・Tell the customer to see the Online Document Set 2 from the following URL:
http://support-download.com/services/device/ccmanual/MP2554SP/en/pdf/User.html
・Tell the customer to see the Online Document Set 3 from the following URL:
http://support-download.com/services/device/ccmanual/MP2554SP/en/pdf/
DriverInstall.html
・Tell the customer to see the Online Document Set 4 from the following URL:
http://support-download.com/services/device/ccmanual/MP2554SP/en/pdf/Oss.html
・Tell the customer to download the Online Document Set 5 (the information about the
Technical Bulletin PAGE: 2/11
Model: Cor-C1 Date: 08-Dec-15 No.: RD197066
2. Tell the customer to read the “Notes for Administrators: Using This Machine in a
Network Environment Compliant with IEEE Std 2600.2TM-2009”.
By comparing the ADF and the images in "2. Installation", "ARDF DF3090", "Installation
Procedure" in "Model COR-C1 Machine Code: D197/D198/D199/D200/D201/D202 Field
Service Manual", and by comparing the ADF and the images in "2. Installation", "SPDF
DF3080", "Installation Procedure" in "Model COR-C1 Machine Code:
D197/D198/D199/D200/D201/D202 Field Service Manual", confirm that no suspicious
parts or devices are attached to the ADF cable.
Firmware versions with which the COR-C1 models (SP models) first achieved CC-
CERTIFICATION:
(October 2015)
Ic Key and Ic Hdd versions with which the COR-C1 models (SP models) first achieved CC-
CERTIFICATION:
(October 2015)
Hardware: Version:
Ic Key 01020714
Ic Hdd 3330
Technical Bulletin PAGE: 6/11
Model: Cor-C1 Date: 08-Dec-15 No.: RD197066
<For EU (D249/D250/D251)>
Paper Documents
Technical Bulletin PAGE: 7/11
Model: Cor-C1 Date: 08-Dec-15 No.: RD197066
・D202-7007 MP 2554/3054/3554/4054/
5054/6054 series
Read This First
・D202-7360 Notes for Using This Machine Safely
・A232-8561A Safety Information
・D202-7365A Notes for Users
・D193-7657 SOFTWARE LICENSE AGREEMENT
・D193-7659 NOTICE TO USERS
<For EU (D200/D201/D202)>
Paper Documents
・D202-7007 MP 2554/3054/3554/4054/
5054/6054 series
Read This First
Technical Bulletin PAGE: 8/11
Model: Cor-C1 Date: 08-Dec-15 No.: RD197066
<For KOR_J(D197/D198/D199)>
Paper Documents
・D202-7009 MP 2554/3054/3554/4054/
5054/6054 series
Read This First
・D202-7150 Notes for Using This Machine Safely
・D193-7658 SOFTWARE LICENSE AGREEMENT
・D193-7659 NOTICE TO USERS
・D202-7058C Notes for Users
・D202-7474 Print
・D202-7475 Scan
・D202-7476 Troubleshooting
・D202-7477 Connecting the Machine/ System Settings
・D202-7478 Security Guide
・D193-7479 Extended Feature Settings
・D202-7480 PostScript 3
・D202-7481 Appendix
Reissued:21-Dec-15
Model: Cor-C1 Date: 11-Dec-15 No.: RD197067a
RTB Reissue
The items in bold italics were added
Subject: SC142 occurs after replacing a “LENS:HOLDER:ASS'Y” Prepared by:T.Hirakawa
From: 1st Tech. Support Sec. Service Support Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2 Tier 0.5
SYMPTOM
SC142-00 occurs after replacing the lens holder assembly with the service part
(LENS:HOLDER:ASS'Y, P/N: D2021771).
CAUSE
The focus adjustment and positioning adjustment of the lens and CCD (service parts only)
were not performed at the RMT factory.
SOLUTION
Production line:
The adjustments have been performed on lens holder assemblies beginning in January
2015.
In the field:
Replace the assembly.
Important: Use the information below to identify the affected service parts from
unaffected (normal) service parts.
Technical Bulletin PAGE: 2/2
Reissued:21-Dec-15
Model: Cor-C1 Date: 11-Dec-15 No.: RD197067a
How to identify the affected and unaffected (OK) parts
Check the production date by looking at the lot number on the packaging.
The lot number is circled in red in the photo below.
The right 4 digits show the production date (example: production month: 01,
production year: 14)
Subject: FSM revision (1 Bin Tray BN3110 Installation Procedure) Prepared by: T. Tachibana
From: 1st Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2 Tier 0.5
2. Installation
- 1 Bin Tray BN3110 (D692/ D3CQ)
Accessory Check
No. Description Q’ty Note
1 Tray support bar 1
2 Harness cover 1
3 Tray 1
4 Screw: M3 x 8 2
5 Gear 1
6 Left lower cover 1 D3CQ Only
Technical Bulletin PAGE: 2/3
Model: Cor-C1 Date: 22-Dec-15 No.: RD197068
Installation Procedure
(D3CQ Only) Before installing the 1 bin tray, attach the left side cover to the left cover.
1. Attach the cover from the left side by matching the bosses.
Continue with the 1 Bin Tray installation procedure as described in the service manual (P151~).
Technical Bulletin PAGE: 1/1
Model: Cor-C1/Cor-C1_SOP/Gim-MF1d/ Gim-MF1dM/GR-C2/GR- Date: 21-Jan-16 No.: RD184064
C2_SOP/ Lef-C1/OR-C2/OR-C2_SOP
This RTB has been issued to announce the firmware release information for the PCL Font.
This RTB has been issued to announce the firmware release information for the Font EXP.
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
RTB Reissue
The item in bold italics was corrected.
Subject: HE Model Installation Procedure Prepared by: Y.Taniguchi
From: 1st Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (New model) Tier 2
For NA ONLY
The new HE model, targeting only the NA market, will launch in Feb 2016. This model will
be available for the following product series:
- D146-D150 series: MP C3003/C3503/C4503/C5503/C6003
- D197-D202 series: MP 2554/3054/3554/4054/5054/6054
- Peripherals: Paper Feed Unit PB3160 (for D146-D150)
Paper Feed Unit PB3220 (for D197-D202)
|1)| |2)|
] ]
|3)|
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
Overview
D146-D150 / Touch D146-D150 / Swipe
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
Accessories Check
3 Keyboard 1
4 Keyboard Tray 1
7 Keyboard Bracket 1
9 Cover:Cables 1
10 BRACKET:SHIFT:D197-D202 1
11 COVER:FRONT:UPPER:(for D146-D150) 1
12 COVER:FRONT:UPPER:(for D197-D202) 1
A SCREW:M3X10 2
B SCREW:M3X6 13
C SCREW:M4X10 1
D SCREW:M4X6 2
E SCREW:M4X12 2
F SCREW:M3X8 2
G Clamp 3
Technical Bulletin PAGE: 4/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
[3]
[1] [2]
[6]
[4] [5]
[9]
[11] [12]
Technical Bulletin PAGE: 5/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
Installation Procedure
3. Replace the upper piece of the Main Power Switch Cover. ( x2)
Technical Bulletin PAGE: 6/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
5. Attach the clamps (x3) to the right hand side of the scanner unit.
Technical Bulletin PAGE: 7/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
6. Insert the cable of the Card Reader through the cover and bracket as shown below.
Screw: B (x4)
Screw: A (x2)
Technical Bulletin PAGE: 8/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
Screw: F (x2)
Screw: B (x1)
11. Insert the cable of the Keyboard through the Keyboard Tray.
Technical Bulletin PAGE: 9/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
12. Insert the cables of the Card Reader and Keyboard through the Bracket.
13. For D197-D202 ONLY: Insert the cables through the hole in the Shift Bracket.
14. Insert the cables through the Main Power Switch Cover.
Technical Bulletin PAGE: 10/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
15. Route the cables through the top of the controller box as shown.
17. Route the cables under the Scanner front cover and lock with the clamps.
Technical Bulletin PAGE: 11/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
Screw: E (x2)
Screw: C (x1)
Technical Bulletin PAGE: 12/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
Screw: E (x2)
Screw: C (x1)
D197-D202
Screw: D (x2)
Screw: B (x1)
Screw: B (x3)
Technical Bulletin PAGE: 13/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
Screw: B (x4)
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
24. Remove the cutout from the left rear cover to make a hole for the cable.
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
Note:
Check with the customer or the sales person before attaching the decal. If the
customer wishes to use the Bypass Tray, do not attach it.
Accessories Check
1 Decal:Bypass Tray 1
Installation Procedure
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
Parts Catalog for HE models
[3]
[1] [2]
[6]
[4]
[5] [7]
Technical Bulletin PAGE: 17/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
[8] [9]
[1] Note:
Two spare keys come with
the part.
[2]
[4]
Technical Bulletin PAGE: 18/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
[1]
[2]
[1]
[2]
Technical Bulletin PAGE: 19/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
[1]
[2]
[1]
[2]
Technical Bulletin PAGE: 20/20
Reissued: 19-Feb-16
Model: MET-C1/COR-C1 HE Model (for NA Only) Date: 10-Feb-15 No.: RD197069a
[1]
[2]
[1]
[2]
Technical Bulletin PAGE: 1/1
Model: Cor-C1 Date: 30-Mar-16 No.: RD197070
Subject: Parts Catalog Correction: Separate bracket of the Prepared by: T. Tachibana
paper feed unit
From: 1st Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2
Old part New part Description Q’ty Int Page Index Note
number number
D1472736 D2412736 BRACKET:SEPARATE:REAR 2-2 X/X - - Set
D2412730 STAY:SEPARATE:PEEN 0-1 - - - as
O/O
Note: When replacing the Separate bracket, replace together with the Separate Stay as a
set.
Technical Bulletin PAGE: 1/1
Reissued: 05-Jan-17
Model: Al-C2/AP-C3/AT-C3/MT-C5/Ch-C1/Cor-C1/MET- Date: 23-Feb-12 No.: RD129022c
C1ab/MET-C1ab_ch/MET-C1cde/MET-C1cde_ch/MET-
C1yz/MET-C1yz_ch/MET-C2ab/MET-C2cde/MET-
C2yz/OR-C2/OR-C2_ch/MT-C6/Ch-C2/Cor-C1.5
RTB Reissue
The items in bold italics have been corrected or added.
Subject: Firmware Release Note: SG3-ND Prepared by: M. Kumagai
From: 1st Tech Service Sect., MFP/Printer Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other (Firmware) Tier 2
This RTB has been issued to announce the firmware release information for the SG3-ND.
SYMPTOM
The front lever is broken when the duplex unit is opened and closed.
Affected models:
Met-C2abcde (D238/D239/D240/D241/D242),
Met-C1abcdeyz (D146/D147/D148/D149/D150/D176/D177),
Cor-C1 (D197, D198, D199, D200, D201, D202)
CAUSE
The strength of the front lever was decreased when a modification was applied to this part
in March 2016.
SOLUTION
If the symptom occurs, replace the lever (P/N: D2399901).
Technical Bulletin PAGE: 2/3
Model: MET-C1b Date: 25-Aug-16 No.: RD147161
PROCEDURE
1. Open the duplex unit.
PROBLEM
Small insects may get inside the machine from the open space at the bottom right.
Technical Bulletin PAGE: 2/2
Model: Corona-C1cdefgh Date: 3-Feb-17 RD197071
SOLUTION
Procure and install the cover [A] below.
1 D1491268 COVER:RIGHT:LOWER 1
Technical Bulletin
Model: COR-C1 Date: 13-Apr-17 No.: RD197072
Subject: SC670-00 occurs frequently Prepared by:
From: 1st FQM Sect, 1st FQM Dept. Yuusuke Taniguchi
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2
SYMPTOM
SC670 occurs frequently.
CAUSE
Insufficient contact of the ground plate for the Fusing Unit/Paper Exit Unit.
When the plate is deformed, it may lose contact with the metal frame of the fusing unit or
paper exit unit. As a result, electrical noise (produced by paper transport inside the unit) is
not discharged through the plate correctly.
Note: Please be careful not to deform the plate when installing such a unit.
SOLUTION
Do the following:
Correct the deformation in the ground plate as shown in the photos, so that the plate
touches the contact point on the frame.
Fusing unit:
Technical Bulletin
Model: COR-C1 Date: 13-Apr-17 No.: RD197072
If SC670-00 still occurs, do the action in the following flowchart (from the Field Service
Manual).
Note: This is because the cause is different from the one described above.
Technical Bulletin PAGE: 1/2
Reissued: 22-Jun-17
Model: Cor-C1 Date: 7-Jun-17 No.: RD197073a
RTB Reissue
The item (only Model name) in bold italics was corrected.
Subject: Parts Catalog Correction: Front Door and Case Prepared by: K. Moriizumi
From: 1st Tech Service Sect., MFP/P Tech Service Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2 Tier 0.5
Old part New part Description Q’ty Int Page Index Note
number number
D2021242 D2011242 DOOR:FRONT 1-1 X/X - - Set
D2021241 D2011241 CASE:DOOR:FRONT 1-1 X/X - - as
O/O
Note: When replacing the front door, replace the front door case also at the same time.
Technical Bulletin PAGE: 2/2
Reissued: 22-Jun-17
Model: Cor-C1 Date: 7-Jun-17 No.: RD197073a
Technical Bulletin
Reissued: 11-Jan-18
Model: Cor-C1 Date: 25-Aug-17 No.: RD197074a
RTB Reissue
The item in bold italics were corrected.
Subject: SC672-11 always occur just after System Reset Prepared by: Y. Taniguchi
From: 1st FQM Sect, 1st FQM Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2
SYMPTOM
SC672-11 occurs just after a “System Reset” is performed on the Affected Models below.
Note:
The machine works normally until System Reset is performed.
A System Reset is performed in the following cases:
- Remote installation of a solution app
- After RFU/ARFU completed
- The # and * keys are pressed together for 10 seconds
- Remote reboot via WIM (HDD format, A time area change and a
measurement unit change “mm/inch”).
The above operations are completed normally, but SC672-11 will occur and it
must be cancelled when by the manual power OFF/ON.
CAUSE
Defective NAND chips are used on controller boards produced between Aug 2016 to April
2017 (see Affected Models below). A software bug is in the NAND chip. As a result of this
bug, the chip cannot perform a restore after the System Reset, which triggers the SC.
NAND chip
Technical Bulletin
Reissued: 11-Jan-18
Model: Cor-C1 Date: 25-Aug-17 No.: RD197074a
Affected Models
- COR-C1 (MP 2554/3054/3554/4054/5054/6054)
- GR-C2 (MP C306/C307)
- Lef-C1 (MP 305+)
- Z-P2 (SP C435DN/C440DN)
- Service parts of Controller Boards for the above models.
SOLUTION
Production line:
The NAND chip was modified (applied from: April 2017 production).
Note: This was applied to the Lef-C1 and Z-P2 only, since production of the COR-C1 and GR-C2
have already been discontinued.
In the field:
A new firmware module “NAND FLASH” is added. Install this firmware into the affected
NAND chip by the following procedure.
1) Update System/Copy to the following version or later. This is a preparation for installation
of NAND FLASH firmware.
Product Firmware name P/N Version
COR-C1 System/Copy D2025550X 1.19
COR-C1_SOP System/Copy D2015550W 1.19
GR-C2 System/Copy D1965400R 1.14
LEF-C1 System/Copy D2595552M 1.11
Z-P2a System M2575735B 1.02
Z-P2b System M2575731D 1.05
Important:
- Both firmwares cannot be updated at the same time (by SD card and remote update).
Please be sure to follow the order above because NAND FLASH cannot be installed unless
the System/Copy is updated to this version.
- Either the new System/Copy or NAND FLASH is available for RFU/ARFU, but a System
Reset is performed after step 1) completed, and then SC672-11 occurs because the
affected NAND chip is not modified yet at that moment. Second System Reset will be
performed after step 2) but SC672-11 does not occur at that time.
- If the System/Copy is the new version or later, the version information of NAND FLASH
can be shown on SMC Diagnostic report. If the version is “Q0310E” or later, NAND FLASH
is installed correctly.
- In the case that a customized System/Copy firmware have been installed to the machine,
please overwrite System/Copy with the customized version after the procedure above.
Once the software in NAND chip is modified, System/Copy can be downgraded to the
customized version.
Affected S/N
Product Affected S/N Production month
COR-C1c/COR-C1c_(SOP) G146x800001~ Aug 2016 to
COR-C1d/COR-C1d_(SOP) G156x800001~ Discontinuation
COR-C1e/COR-C1e_(SOP) G166x800001~
COR-C1f/COR-C1f_(SOP) G176x800001~
COR-C1g/COR-C1g_(SOP) G186x800001~
COR-C1h/COR-C1h_(SOP) G196x800001~
GR-C2a (SP model) G436P800001~ Aug 2016 to
GR-C2a (SPF model) G446P800001~ Discontinuation
GR-C2b (SP model) G276P800001~
GR-C2b (SPF model) G136P900001~
Lef-C1 G586P902194~ Aug 2016 to Apr 2017
G587P400986
Z-P2a Y016P900085~ Aug 2016 to Apr 2017
Y017P100040
Z-P2b X686P900477~
X687P500096
Note:
- Not all units which are produced in this period are affected. Some units should not be
affected.
- Besides, also some service parts for CTL board have been affected. A machine which is
not produced in the period may be also affected if its CTL board has been replaced.
Technical Bulletin
Reissued: 11-Jan-18
Model: Cor-C1 Date: 25-Aug-17 No.: RD197074a
Reissued: 19-Mar-18
Model: Cor-C1 Date: 28 -Nov-17 No.: RD197075a
RTB Reissue
The items in bold italics were corrected or added.
Subject:Part catalog correction: Guide plate for Prepared by: H.Kameda
PB3150/PB3160/PB3170/PB3230
From: Technical Support Sect., Product Marketing Dept.
Classification: Troubleshooting Part information Action required
Mechanical Electrical Service manual revision
Paper path Transmit/receive Retrofit information
Product Safety Other ( ) Tier 2 Tier 0.5
Shape
1. Deleted stopper
2. Changed angle regulation
3. Strengthened part
Technical Bulletin PAGE: 2/9
Reissued: 19-Mar-18
Model: Cor-C1 Date: 28 -Nov-17 No.: RD197075a
Angle
Technical Bulletin PAGE: 3/9
Reissued: 19-Mar-18
Model: Cor-C1 Date: 28 -Nov-17 No.: RD197075a
Procedure:
1. Release the hook and remove the guide plate.
Reissued: 19-Mar-18
Model: Cor-C1 Date: 28 -Nov-17 No.: RD197075a
Parts catalog correction 2
Affected model: D693 (Paper Feed Unit: PB3160)
Change: Added cushions and changed the shape of the guide plate.
Reason: To further strengthen and prevent breaking of the guide plate.
Important: Be sure to attach the above CUSHION when installing the paper guide plates.
2. Remove the auxiliary guide plate for the “lower paper guide:lower” (screws x1).
Technical Bulletin PAGE: 5/9
Reissued: 19-Mar-18
Model: Cor-C1 Date: 28 -Nov-17 No.: RD197075a
4. Attach the auxiliary guide plate for the lower guide plate (screw x1).
Reissued: 19-Mar-18
Model: Cor-C1 Date: 28 -Nov-17 No.: RD197075a
Important: Be sure to attach the above CUSHION when installing the paper guide plates.
Reissued: 19-Mar-18
Model: Cor-C1 Date: 28 -Nov-17 No.: RD197075a
Important: Be sure to attach the above STOPPER, when installing the paper guide plates.
Procedure
1. Remove the guide plate.
Reissued: 19-Mar-18
Model: Cor-C1 Date: 28 -Nov-17 No.: RD197075a
Reissued: 19-Mar-18
Model: Cor-C1 Date: 28 -Nov-17 No.: RD197075a
SYMPTOM
The following occur if the toner bottle is replaced at Toner Near End:
- The Supply Call for Toner bottle is not sent to the @Remote Center even though
SP5-507-080 (Toner Call Trigger) is set to “0: Toner replacement” (default).
- The value of SP8-781-001 (Toner Replacement Counter) does not count up.
Note: This does not occur if the bottle is used until Toner End.
CAUSE
Software Bug in the Engine firmware
SOLUTION
Update the Engine firmware to the modified version or later.
SYMPTOM
The following may occur:
- Black lines, toner dropping, or dirty background
- A smashing/impact noise
- The waste toner transport coil breaks
CAUSE
- The PCU drive unit gear (D2021126) breaks due to excessive loads or other factor. As a
result, the waste toner (unit) transportation mechanism cannot be driven, and toner
coagulates inside the waste toner unit and PCU (Ex., in the PCU upper cover, as
shown in the photo).
- The machine is used even after the waste toner bottle is full. As a result, the waste toner
coagulates inside the waste toner unit and PCU (Ex., in the PCU upper cover, as shown
in the photo).
Note: The waste toner replacement message can be temporarily cleared by just
removing the bottle and placing it back in the machine (even if still full).
Technical Bulletin
Model: COR-C1 Date: 7-Jun-18 No.: RD197077
SOLUTION
Production line:
The gear was strengthened to prevent breakage.
Note: This modification was applied to the Cor-C1.5 and Cor-P1.5 since May 18 production,
but not to the Cor-C1 (as this model has since been discontinued).
In the field:
1) Check the status of the waste toner bottle, and replace it if it is full of waste toner.
2) Replace the PCU.
3) Replace the waste toner unit.
See: FSM “Replacement and adjustment” -> “Drive unit” -> “Waste toner Shutter
Solenoid”.
P/N Description
D2026511 BRACKET:TONER RECYCLING
SECTION:MAIN ASS'Y:ASS'Y