Straight Connectors

The 'elmex' PV Solar Straight Connectors EMPV4 and EMPV4N are constructed from flame retardant engineering thermoplastic suitable for UV exposure and PV power generation. They have an IP68 water tight seal and are supplied as male and female connectors to minimize wrong connections. The connectors are certified for 2.5, 4.0, 6.0 mm2 double insulated and UV protected solar cables, as tested for 500 hours of UV exposure. Key features include TUV certification, snap fit locking, low contact resistance, and IP68 protection when mated.

Uploaded by

SEO BDM
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
74 views1 page

Straight Connectors

The 'elmex' PV Solar Straight Connectors EMPV4 and EMPV4N are constructed from flame retardant engineering thermoplastic suitable for UV exposure and PV power generation. They have an IP68 water tight seal and are supplied as male and female connectors to minimize wrong connections. The connectors are certified for 2.5, 4.0, 6.0 mm2 double insulated and UV protected solar cables, as tested for 500 hours of UV exposure. Key features include TUV certification, snap fit locking, low contact resistance, and IP68 protection when mated.

Uploaded by

SEO BDM
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

‘elmex’ PV Solar Straight Connectors

‘elmex’ PV Solar Straight connectors EMPV4 and EMPV4N with plug and socket design are constructed using flame retardant engineering
thermoplas c suitable for exposure to UV rays and for applica on in PV power genera on system. These connectors incorporate a flexible
water ght sealing conforming to IP 68 and are supplied as ‘male (plug)’ and ‘female (socket)’ types to minimize the chance of wrong
connec ons. For proper assembly of individual male and female connectors and for proper func oning of the mated pair, it is necessary
that solar cables used are TUV cer fied as per standard 2Pfg 1169/EN 50618. ‘elmex’ straight connectors are cer fied for PV solar cables
2.5, 4.0, 6.0 mm2 size, double insulated (Insula on plus black) & UV protec on (as UV rays tend to damage the connec on).

with NEC Interlock*

EMPV4 EMPV4N

Features
v TUV Cer fied v Low Contact Resistance
v Snap Fit Locking Arrangement v Provides UV Protec on (Tested for 500 hrs as per ISO 4892-2)
v IP 68 Protec on when mated v Tested as per Interna onal Standards / IEC 62852

Descrip on Specifica ons


Rated Voltage 1500V DC
Rated Current 25A (2.5 mm2), 30A (4.0 mm2, 6.0 mm2)
RMS Test Voltage 8 kV (1500V)
Impulse with stand Voltage 16 kV
Degree of Protec on IP 67 / IP 68
Contact Material Copper with Tin Pla ng
Ambient Temperature -40o C to +85o C
Max. Opera ng Temp. +110O C
Pollu on Degree 3
Contact Resistance < 0.5 mΩ
Inser on Force ≤ 50 N
Withdrawal Force ≥ 50 N
Locking System Snap In R60126561

Note : Our Connectors are suitable for PV Solar Cables of 2.5 / 4.0 / 6.0 mm2 diameter (As per 2Pfg 1169 / EN 50618).
*Connectors when mated, need a tool to open in accordance with NEC 2014.

Manufactured in Vadodara, Gujarat, India