High Performance Vector Control Inverter: Product Series
High Performance Vector Control Inverter: Product Series
High Performance Vector Control Inverter: Product Series
SB70G
High Performance Vector Control Inverter
COMPANY PROFILE
As one of the earliest companies which embark upon the frequency conversion
technology research field, SLANVERT has become one of the biggest inverter
manufacturers in China. SLANVERT is one of the winner of 'China Top Brand' in
China's low-voltage inverter industry that had successfully obtained international
standards such as ISO9001:2008, ISO14001 and CE certifications. SLANVERT
enjoys the reputation of 'Chinese Frequency Technology Expert' as we own an
independent intellectual property system that is supported by dozens of patents and
proprietary technologies. Based on these technologies and patents, SLANVERT has
successfully developed many top rank Chinese high-quality inverters include SB70
series, SB60/61 series, SB60+/61+ series, SE62 series, SB61Z+ series, SBH series,
and SB200 series. Our products are widely used in many fields such as metallurgy,
machinery, building material, chemical industry, petroleum, biotechnology and
pharmacy. Our efforts and contribution finally won lots of honour’s, such as 'Gold
Medal of the Fourth Shanghai Science and Technology Exposition', 'Gold Medal of
China Fair of Inventions and Technologies', 'National Torch Program Project',
'National Innovation Fund Project' and 'National Key & New Product Project'.
PRODUCT OVERVIEW
APPLICATION FIELDS
Frequency converters of SLANVERT SB70G series are widely applied draw bench,
blender, extruder, air compressor, grinder, belt conveyor, hoister, centrifuge,
numerically-controlled machine tool, food and packing machinery, and drive, fans
and bumps used in various industries.
FUNCTIONAL CHARACTERISTICS
Programmable modules
2 groups of comparators and 4 groups of logical units are internally set
4 groups of timers and 6 groups of arithmetic units
TECHNICAL SPECIFICATIONS
Item Description
Rated voltage
1Ph: 200V, 3Ph:200V/400V/690V/1140V; 50/60Hz
Input and frequency
Range Fluctuation range:-15%~10%;imbalance:<3%;Frequency:47-63Hz
Voltage 0~input voltage;with the error less than 5%
Output Frequency
V/F control:0~650Hz; Vector control:0~200Hz
range
Motor control V/F control without PG,V/F control with PG, vector control without PG, vector
mode control with PG,V/F separate control
Steady-state
speed vector control without PG:≤1%,vector control with PG:≤0.02%
precision
Starting
Not less than 150% or rated torque at 0.5Hz
torque
Overload
150% of rated current for 1 minute
capacity
Frequency
Digital reference:0.01Hz,Analog reference:0.1% of max frequency
resolution
Output Analog reference:±0.02%of max frequency(25±10℃)
frequency
Digital reference:0.01Hz (-10~40℃)
precision
Basic Specifications
Operating
command Keypad, terminal and communication. They can be switched over by terminals
channel
Frequency
Keypad, communication, UP/DOWN value, AI1, AI2,
setting
PFI and arithmetic unit
channel
Torque boost Manual, auto, manual + auto
V/F curve User defined V/F,linear V/F and 5 reduced-curves
Accel/decel Linear or S-curve acceleration/deceleration
JOG Jog frequency:0.1~50Hz,Jog acel / decel:0.1~60S
Auto energy V/F curve is optimized automatically based on the load condition, achieving auto
saving energy-saving run
Keep the output voltage constant automatically when the voltage of power grid
AVR
fluctuates
Momentary
Ensures uninterrupted operation by controlling the DC link voltage
power failure
Dynamis
Built-in braking unit and external braking resistor for models of 15KW or less
braking
DC braking Braking time:0-60S,braking current:0-100% of rated current
Highest input frequency:50KHz/ Open-collector pulse (aquare wave) output of 0-
PFI/PFO
50KHz,programmable
Terminal
WIRING
P+, N- DC bus terminal Connect a braking unit, common DC bus or external rectifying
unit. Contact us for the usage of the common DC bus.
485+/- 485 differential RS485 communication prot Connect 1-32 RS485 station(s)
signal Input impedance:>10KΩ
GND Ground Grounding terminal for analog Its inside is isolated from
I/O,PFI,PFO,communication,+10v COM,CMX and CMY
or 24v power
+10v +10v reference +10v power supply offered to Max.output current is 15mA, the
power supply user voltage accuracy better than 2%
PFO Pulse frequency View analog output menu 0—50 kHz, open collector
output output;
Specification: 24V/50mA
24V 24V power terminal 24V power supply offered to user Max. output current:80mA
AI1/2 Analog input Jumpers CJ1/2 are used to select Input voltage:
the output type(voltage or -10~+10V 110KΩ
current) Input current:
-20~+20mA 250Ω
Digital input Common terminal for X1-X6, Its inside is isolated from COM
CMX
common terminal FWD,REV and P12.
P12 12V power supply offered to user
12V power terminal Max. output current:80mA
COM Ground of 12V power
Digital output Opto-isolation, bi-directional,
Y1/2 View digital output menu
terminal Open collector output,
Specification: 24V DC/50mA
Common terminal Common terminal of Y1/2 digital Action frequency: <500Hz
CMY Start-up voltage: 2.5V
of Y1/2 output
(relative to CMY)
TA-TB: normally open
1TA/B/C Relay output TB-TC: normally closed
View digital output menu
2TA/B/C terminal Contacts: AC 250V 3A
DC 24V 5A
2: Multistep frequency 2 18: Coast stop 34: DC braking(at stop) 47: Multi-PID select 2
3: Multistep frequency 3 19: UP/DOWN increase 35: Process PID disabled 48: Multi-PID select 3
4: Multistep frequency 4 20: UP/DOWN decrease 36: PID 2 49: Zero-servo command
5: Multistep frequency 5 21: UP/DOWN clear 37: 3-wire stop command 50: Counter preset
6: Multistep frequency 6 22: PLC control disabled 38: Internal virtual FWD terminal 51: Counter clear
7: Multistep frequency 7 23: PLC operation pause 39: Internal virtual REV terminal 52: Meter-counter clear
8: Multistep frequency 8 24: PLC standby state reset 40: Analog reference frequency hold 53: Wobble frequency injection
9: Accel/decel time select 1 25: PLC mode select 1 41: Accel/decel disabled 54: Wobble state reset
10: Accel/decel time select 2 26: PLC mode select 2 42: Run command source switched to 55:Fan running time
terminal/keypad clear
11: Accel/decel time select 3 27: PLC mode select 3
12: External fault input 28: PLC mode select 4 43: Reference frequency switched to
56: PFI Location given reverse
13: Fault reset 29: PLC mode select 5 AI1(top priority)
14: Jog forward 30: PLC mode select 6 57:Motor Rated current 1
44: Reference frequency switched to
15: Jog reverse 31: PLC mode select 7 arithmetic unit 1(2nd top priority) 58:Motor Rated current 2
6: Reference torque 17: Counter error 29: Comparator 2 digital setting 41: Keypad POT value(POT:
7: PID feedback value 18: Count percentage 30: Arithmetic unit 1digital setting potentiometer)
8: PID reference value 19: Arithmetic unit 1 output 31: Arithmetic unit 2digital setting 42: Counter 2 count value
9: PID output value 20: Arithmetic unit 2 output 32: Arithmetic unit 3digital setting 43: 1 Temp of the radiator
10: AI1 21: Arithmetic unit 3 output 33: Arithmetic unit 4digital setting 44: 2 Temp of the radiator
11: AI2 22: Arithmetic unit 4 output 34: Arithmetic unit 5digital setting
Notes: As to the products with voltage class of 690V, on-hook products with
18.5~315kW are conventional. Products with other specifications are customized
products. If you have any requirement, please consult with the local agency or
personnel of our company.
In addition, the company also can customize special frequency converter with supply
voltage being 1140V. If you have any requirement, please consult with the local
agency or personnel of our company.
DIMENSION
SB70G0.55D2
SB70G0.75D2
SB70G0.75
Wall
SB70G1.5 mounted
type
SB70G1.5D2
SB70G2.2D2
135 240 140 170 125 230 φ4.5 3
SB70G2.2
SB70G4
SB70G4T2, SB70G5.5T2,
SB70G5.5~SB70G15
SB70G4T2
SB70G5.5T2
150 300 195 138 288 φ5.5 7
SB70G5.5 Wall
SB70G7.5 mounted
type
SB70G11
200 380 225 185 367 φ7 10
SB70G15
SB70G18.5~SB70G375, SB70G18.5T6~SB70G315T6
Outlines and installation dimensions of SB70G355T6 and above are shown in the
following table:
Overall dimensions Mounting dimensions
Structure Weight
Model W H H1 D A B d Form (kg)
(mm) (mm) (mm) (mm) (mm) (mm) (mm)
SB70G355T6C 350
SB70G375T6C 800 2200 320 800 550 700 φ12 350
SB70G400T6C 400
SB70G450T6C 450
1200 2200 320 600 1050 450 φ14 Cabinet
SB70G500T6C 500
type
SB70G560H6C 1600 2200 320 600 460/660 500 φ14 600
SB70G630T6C 1200 2200 320 600 1050 450 φ14 650
SB70G710T6C
1200 2200 320 600 1040 506 φ14 730
SB70G850T6C
SB70G900T6C
SB70G1000T6C
Customized type
SB70G1100Q6C
SB70G1200H6C
SELECTION OF ACCESSORIES
Brake unit
If the frequency converter has brake units internally set, just
choose the appropriate braking resistance.
If the frequency converter does not have brake units internally
set, brake units of SZ series and braking resistance are needed.
Braking resistance should be determined according to the actual
generated power of loading, frequency of power generation, etc.
Resistance should not be more than 1.5~2.0 times of the value
recommended.
Communication components
Extension cord components on the operation panel
Background monitor software SB Monitor
Profibus-DP module
SERVICE NETWORK
Greater China
International
CHINA
No.181, Airport Road,
South West Airport Development Zone
Chengdu, P.R. China 610225
Tel: +86 28-8596 3211
Fax: +86 28-8596 5772