0% found this document useful (0 votes)
58 views2 pages

OptiClean Air Handler

The Carrier OptiClean™ rolls easily into any room and plugs into a standard electrical outlet to quickly improve indoor air quality (IAQ) in schools, dental offices, hospitals, and other commercial facilities. It can be operated in two modes: Air Scrubber —uses 99.97% efficient, long-life HEPA filters to remove particles as small as 0.3 microns, then discharge cleaner air back into the room. Ideal for a wide range of commercial applications, including K–12 classrooms , dental office exam rooms

Uploaded by

carrier india
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
58 views2 pages

OptiClean Air Handler

The Carrier OptiClean™ rolls easily into any room and plugs into a standard electrical outlet to quickly improve indoor air quality (IAQ) in schools, dental offices, hospitals, and other commercial facilities. It can be operated in two modes: Air Scrubber —uses 99.97% efficient, long-life HEPA filters to remove particles as small as 0.3 microns, then discharge cleaner air back into the room. Ideal for a wide range of commercial applications, including K–12 classrooms , dental office exam rooms

Uploaded by

carrier india
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CARRIER OPTICLEAN™

NEGATIVE AIR MACHINE


FN1SXF00500G

The Carrier OptiCleanTM negative air machine is a portable, solution primarily designed to help convert
normal hospital rooms into airborne infectious isolation rooms (AIIR). Designed to comply with ASHRAE’s
Standard 170 for Ventilation of Health Care Facilities, the Carrier OptiCleanTM uses a 99.97% efficient filter
and a heavy duty, yet quiet, motor to remove filtered contaminated air from the room. The resulting negative
air pressure, or “vacuum effect,” helps limit the spread of airborne contaminants into surrounding areas.
If negative pressure is not required, such as an open-air, temporary hospital, the machine can be used
as an air “scrubber,” pulling air in, removing many contaminants, and discharging cleaner air
back into the space.

Product Highlights and Specifications


• 99.97% efficient, long-life HEPA filter removes • Portable and adaptable to nearly any
particles as small as 0.3 microns. appropriately-sized location.
• Pleated synthetic MERV 7 pre-filter. • Heavy-duty, lockable casters for easy transportation.
• Nominal Air Flow: • Red filter indicator light alerts user when it’s time to
687 CFM in Air Scrubber mode replace a filter.
500 CFM in Negative Air mode
• Green on/off switch illuminates when the unit is on
(0.45 in w.g. ESP)
and operating.
• 5 selectable motor speeds for wide range of airflow.
• 3 meters long power cord with strain relief and plug type G.
• Meets ASHRAE Standard 170: Ventilation of Health Care
Facilities. • Exhaust transition plate to standard 10-inch round.

• HEPA filter rack and sealing design meeting filter • Galvanized steel, powder painted cabinet is fully insulated.
air by-pass leakage Class F9 EN 1886. • 230V / 1Ph - 50 Hz Power.
• Vertical design for smaller footprint. • Unit dimensions, cm: 44.5W x 56D x 126H.

Opticlean CFM, ESP, Power


TM

Airflow with factory installed filters MERV 7,


HEPA H13, and standard connector plate.

Note: This catalogue provides certain general information and is intended for general guidance only and Carrier India disclaim any liability
for any damage arising out of the use of this catalogue.
ADDITIONAL PRODUCT DETAILS

Pre-Installed Filters
• The Carrier OptiClean ships with two filters pre-installed for your convenience:
TM

synthetics pleated MERV 7 pre-filter and a HEPA H13 filter.


– MERV 7 pre-filter recommended replacement is 60-90 days.
– The long-life HEPA filter provides approximately 40,000 hours of operation,
or four years, under normal operation and maintenance*

* Applies to negative air machine applications only.


Filter life in air scrubber applications would be reduced.

Multi-Function Control Panel


• On/Off Switch – A green on/off switch illuminates when the unit is on
and operating.
• Filter Alert – A red light illuminates when it is time to check and/or replace
one or both of the unit’s filters.
• Pressure Indicator – Compares room/ambient pressure versus internal
pressure on the back side of the HEPA filter. Sets off the red indicator light
when the filters are dirty.
• 5 selectable motor speeds for wide range of airflow.

Some Assembly Required


• Locking casters and round duct transition assembly are shipped packed
underneath with every unit.

Note: This catalogue provides certain general information and is intended for general guidance only and Carrier India disclaim any liability
for any damage arising out of the use of this catalogue.

Manufacturer reserves the right to discontinue, or change at any time,


specifications or designs without notice or without incurring obligations.
©2021 Carrier. All Rights Reserved.

Corporate & Registered Office: Carrier Airconditioning & Refrigeration Ltd, Narsingpur, Kherki Daula Post, Gurgaon 122004, Haryana, India
Tel: 0124-4825500 Corporate Identification Number: U74999HR1992FLC036104
Website: www.carrierindia.com E-mail: [email protected]