ZEST-ZQ310 Series Catalog
ZEST-ZQ310 Series Catalog
ZEST-ZQ310 Series Catalog
www.zest-electric.com
ZEST Electric Product introduction
ZEST Electric Specialized in developing, manufacturing, selling of industrial automatic ZQ310 is a high-performance VFD with ZEST ELECTRIC that integrates vector frequency
products, also committed to provide excellent integrated solutions! conversion technology. With high-performance current vector technology, it can easily
drive induction motors. The technical and performance problems encountered so far in
ZEST taking up the mission of improving industry automation progress, upholding the
equipment such as cables, machine tools, metal products, petrochemicals, natural
design & development of Independent intellectual property rights, working hard at gas, lifting equipment, pulp and paper, textiles, printing and dyeing, ceramics and
domestic market, established famous brand in this industry, and expanding other industries can be easily solved. High performance, high quality, high power
our business in international market. ZEST Electric determined to be a reliable density design, and significant improvements in ease of use, maintainability,
partner to constantly create value for customers & users. environmental protection, installation space and design standards can further optimize
Now the products are widely used in electric power, mining ,metallurgy ,petroleum, the user experience.
chemical, building materials, lifting, machine tools, textiles, paper, packaging, light-
industry and various industrial automation products.
Customer first is what we always insist, ZEST is committed to becoming one of the leading
1 2
Product Detail Low Loss High Frequency Transformer
Intelligent Control
And Improve The Service Life Of The Fan Resistant To Moisture, Corrosion
3 4
Appearance of Keyboard panel
Main loop wiring diagram
▲ Increase key Function code, menu group, or set parameter value increment
▼ Decrease key Function code, menu group, or set parameter value decrement.
RUN Run key Enter into run mode under keypad model. POWER SUPPLYR
Used for shutdown operation during operation; Reset
MOTOR
STOP stop/reset key
operation key in fault alarm state.
5 6
Product Parameter Product characteristics
7 8
Industry application System wiring diagram
Widely used in electric power, mining ,metallurgy ,petroleum, chemical, building materials, The wiring parts of VFD include major loop and control loop. Open the cover of I/O
lifting, machine tools, textiles, paper, packaging, light-industry and various industrial terminals, users can see the major loop terminal and control loop terminal, and must
automation products. conduct the wiring according to the following diagram.
9 10
Detailed technical specifications Detailed technical specifications
Item Description Item Description
Output Output voltage 0V to the input voltage (continued) Undervoltage Specially for users with a low or unsteady voltage power grid: even lower
Output frequency 0.00 Hz to 500.00 Hz Restrain during than the allowable voltage range, the system can maintain the longest
Running possible operating time based on its unique algorithm and residual energy
Carrier frequency 0.8khz to 8.0khz (automatic adjustment according to the load) allocation strategy
Overload capacity G machine :110% long term; 150% / 1 min Command source Allows different methods of switching between command sources:
Control input
P machine :105% long term; 120% / 1 min and output Operating panel (keypad & display), Terminal I/O control and Serial
Input Voltage/Frequency 3-phase: 380V;50/60Hz signals communication
1-phase: 220V;50/60Hz Main frequency Allows different methods of switching between frequency reference setting
the fluctuation of 3-phase: -15% to 10%, allowable range: 323V AC to 528V AC reference setting channels: Digital setting, Analog voltage reference, Analog current
voltage 1-phase: -15% to 10%, allowable range: 170V AC to 264V AC channel reference, Pulse reference, Communication reference
Frequency range G type: 110% for long-term, 120% for 22 min, 150% for 1min P Auxiliary frequency
Allows fine tuning of the auxiliary frequency and main & auxiliary
type: 105% for long-term, 120% for 8 min, 150% for 1min reference setting
calculation.
channel
Control Frequency Setting Analog Input 0.025% of maximum output frequency
Input terminals 0 to 5V keyboard potentiometer input
Character Resolution Digital Setting 0.01 Hz Six digital input (X) terminals, one of which supports up to 50 kHz high-speed
Control Mode Voltage/Frequency (V/F) control, Sensorless vector control (SVC) pulse inputs.
and Feedback vector control (FVC) MPPT Two analog input (AI) terminals, one of which supports only 0 to10 V input,
Startup torque SVC 0.25 Hz/150% and the other supports 0 to 10 V and 4 to 20 mA current input.
FVC 0 Hz/180% Output terminals Single high-speed pulse output terminal (open-collector) for a square-wave
signal
Speed range SVC 1:200
Single relay output terminal
FVC 1:1000 Single extra AO terminal
Speed stability SVC ±0.5% (SVC) serial
accuracy FVC ±0.02% (FVC) communication RS-485 interface
Torque boost Customized boost 0.0 % to 30.0 % interface
V/F curve Straight-line V/F curve, Multi-point V/F curve, Complete V/Fseparation and Overcurrent, overvoltage, undervoltage, module fault, electric thermal
Half V/F separation Protective Function relay, overheat, short circuit, default phase of input and output, motor
parameter adjustment abnormality, internal memory fault, etc.
Wave current limit In V/F mode, to achieve fast response and ensure the normal operation of
the inverter Display Five digit digital Parameter setting:
Ramp mode Straight-line ramp, S-curve ramp display (LED) and Display parameter number and value.
Four separate acceleration/deceleration time: 0.1s to 6500s Status indicator light
Running state display: Function code,
Automatic voltage The system maintains a constant output voltage automatically when the grid Display operation frequency, current, etc. Data, status
regulation (AVR) voltage changes through the permissible range. Fault display: Display
DC injection braking DC injection braking frequency: 0 Hz to max frequency the fault code.
DC injection braking active time: 0.0s to 100.0s Current Installation location Install the inverter where it is indoors and protected from direct sunlight,
Environment
level of DC injection braking: 0% to 100% dust and corrosive or combustible gases. Running in derated capacity above
Jog running Frequency range of jog running: 0.00 to 50.00 Hz Acceleration/ 1000m.
Deceleration time of jog running:0.0s to 6500.0s Ambient -10°C to +40°C (please run the VFD in derated capacity when ambient
Onboard multiple The system implements up to 16 speeds by using simple PLC function or by Temperature temperature is 40°C to 50°C )
preset speeds using digital input signals. Ambient Humidity 20% to 95%RH, without condensing drops
Overvoltage and Operation
temperature –10°C to +50°C
overcurrent stall Overvoltage and overcurrent stall control
control Vibration Less than 0.5 g
Torque limit and The system limits the torque automatically. Storage temperature –25°C to +65°C
control Torque control is applied in vector control. Installation Method Wall-hanging type, cabinet type
Structure Protection Level IP20
Cooling Method Air cooling with fan control
11 12