Hydrogen Sensor - Honeywell-XNX-Data-Sheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

XNX™ Universal Transmitter

A universal transmitter for


toxic, oxygen and combustible
gas detection compatible with
all Honeywell gas sensing
technologies
XNX Universal Transmitter Universal Gas Sensing Platform

High performance The XNX Universal Transmitter marks a Bringing together the best XNX is designed for flexible integration, simple
• Flammable gas detection 0 to 100% LFL/LEL solutions in gas detection
• Point IR with heated optics provides immunity to new turn in gas detection from Honeywell installation, user friendly operation and straight-
poisoning and no hidden faults Analytics. It supports the widest range of Electrochemical forward maintenance. It is ideal for use with a
• Open-path IR flammable gas detection in LEL-m
measurement sensors on a common platform and offers • 
Proven electrochemical sensing technology range of gas monitoring controllers or industry
• Surecell™ electrochemical cells are ideal for hot
• Electrochemical cell offers toxic gas detection in ppm a modular choice of inputs and outputs. and humid environments
standard PLCs. Users are assured of being
• IR cell provides CO2 and combustible gas monitoring
• Robust and reliable operation in explosive areas and
• Long life sensing cells (typical >2 years) protected in all conditions with Honeywell
harsh environments • Patented ‘Reflex’ sensing element verification Analytics gas monitoring solutions.
diagnostics
Flexible Operation • Sensor recognition software auto configures
• 3  versions - supports mV (Catalytic Bead and IR Cell), transmitter XNX’s modular design enables With the XNX, you are freed from the
Electrochemical Cell and IR (point and open-path) gas • Plug and play factory configured sensors Honeywell Analytics to offer appropriate, need to add extra controllers, junction
detection • Intrinsically safe sensor connection permits hot cost effective solutions to a wide range boxes, relays, monitors and other
• Multi-Purpose Detector (MPD) with field serviceable mV, swap, reducing down time of gas detection requirements. equipment accessories.
Catalytic bead and IR Cell capability
• 4-20mA with HART® as standard Catalytic Bead The XNX Universal Transmitter is an
• Multiple communications options include up to 3 relays, • 
Supports Honeywell Analytics 705, 705HT, excellent choice for those who want a
MODBUS® and FOUNDATION® H1 Fieldbus (pending) Sensepoint, Sensepoint HT and MPD sensors total integrated monitoring and safety
• Optional local IS port for handheld HART configurator • Fast response to wide range of solution for an industrial plant.
hydrocarbons and flammables
Easy to Use
• 
Large, backlit, easy-to-view LCD display offers multi- Infrared (Open Path IR, Point
sensory indicators (visual icons, colored buttons, text, IR, IR Cell)
etc.) to display gas and sensor readings • Supports Honeywell Analytics XNX Technology Enablers
• User interface supported by 8 selectable languages Searchline Excel, Searchpoint
(English, Spanish, German, Italian, Portuguese, French, Optima Plus Catalytic Bead IR Cell Electrochemical Infrared
Russian, Chinese) • Failsafe operation
• Self-test and fault indication features
• Fast speed of response
• Non-intrusive, one-man operation 705/705HT
• Reduced routine maintenance
• Quick calibration with auto-inhibit
• Immune to catalytic poisons
Easy to Install • Long operating life
Sensepoint Optima
• 3  or 4 wire operation, source, sink or isolated • Works in inert atmospheres HT (Point IR)
• Use with conduit or cable installations
• Simple plug-in sensors and replaceable cells MPD
• NEMA 4X IP66 rated for rugged indoor/outdoor use Catalytic
Bead MPD
Cost Effective IR
• 
Minimal training required CELL
• One-man operation
• Plug-in sensor replacement Sensepoint Searchline
• All necessary accessories included ECC Excel
Sensors (Open)
Applications
• 
Offshore Oil & Gas production platforms
mV EC IR
• Onshore Oil terminals
• Refineries
• Gas Transmission XNX Universal Platform
• Gas Distribution
• LNG terminals
• Gas storage terminals
• Chemical plants
• Petrochemical plants Photos not to scale.
• Solvent recovery operations
Communications Installation Details

Mechanical

The XNX enclosure is available in a painted stainless steel or accessories. Inside, customer and sensor connections to the unit
The XNX’s powerful advanced communications module adds increased aluminum housing with a marine grade coating. Five threaded are designed to protect against dangerous electrical misconnections.
conduits/cable entries are available in Metric or NPT versions, and With pending approvals to UL, CSA and ATEX requirements for
functionality and flexibility to a gas detection network. Standard HART ruggedized mounting options provide ultimate installation flexibility. Hazardous Locations, and IP66/67 rating to protect against dirt/water
communications, along with optional Modbus, Foundation Fieldbus (pending) Instrumentation built on various sensing technologies can be
attached locally to the transmitter or remotely with the appropriate
ingress, the XNX serves the most demanding industrial environments.

or relays, interface with a PLC and a host of other protocol compatible devices
found in industrial applications.
Back-lit, easy-to-read LCD display with icons includes a broad range of
language options including English, Spanish, French, Italian, Portuguese,
German, Russian and Chinese to meet global requirements.

Ordering Information
The XNX part numbering system contains all necessary information to convey the product configuration including options. Agency,
Port Thread, Enclosure Material, Sensor Personality define the standard unit. Three option fields are used to define optional Relay or
Fieldbus interfaces and factory installed local HART®. To order XNX parts, call 800-538-0363.

XNX-AM -

Agency Approval Port Threads Enclosure Sensor Interface Option Local HART® Sensor and Range
q q q q q q q q q
ATEX - A M25 - M Stainless - S Electrochem - E None - N None - N None - NNN
UL / CSA - U 3/4” NPT - T Aluminum - A Infrared - I Relay - R Local HART® - H MPD-AM (Catalytic Bead %LEL) - CB1
INMETRO - B milliVolt - V Modbus - M
®
MPD-AMIF1 (IR %LEL Flam) - IF1
Foundation TM MPD-AMIV1 (IR CH4 0-5% Vol) - IV1
Fieldbus - F MPD-AMIC1 (IR CO 0-2% Vol) - IC1
Technical Summary Technical Summary

XNX Transmitter Relay Module (Optional)


Material LM25 Aluminum, painted (SS316 painted optional) Description Provides three fully user configurable relay outputs that can be switched based on the current gas level and/or status of the transmitter. Provides 2 x SPCO
alarm and 1 x SPCO fault relays. Single Pole Double Throw SPDT. Option PCB Factory installed in display module.
Cable Entries 5 conduits/cable entries – (2 right, 2 left, 1 bottom) Available in ¾” NPT, or M25
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Termination Cage Clamp pluggable Terminal Blocks with retaining screws, 0.5 to 2.5mm (12-28 AWG) Rating Maximum: 240VAC, 5A (non inductive load) Minimum: 5V, 10mA (non inductive load)
Electrical Connections Fault: Common, Normally Open, Normally Closed
Mounting XNX Enclosure Bracket (ears on casting for u-bolt). Integral cast mounting flanges provide secure mounting to surfaces, channels or up to 6” Pipe.
Alarm 1: Common, Normally Open, Normally Closed
Optional Remote sensor (up to 50 ft / 15.2 M) for Cat Bead and Toxic
Alarm 2: Common, Normally Open, Normally Closed
User interface Standard Custom Backlit LCD. 2.5” High Resolution DOT Matrix Display. Discrete Alarm and Status indication. Reliable Non-Intrusive 4 button interface magnetic Configuration Default Configurable Options
wand access. Optional HART Handheld with IS Port
Fault Relay: Fault Relay:
Signal Standard HART over 3-wire 4-20mA (sink or source). Optional Modbus over RS-485 and Foundation Fieldbus Normally energized Normally energized / normally de-energized
Non latching None
Environmental Signal inhibit as fault Enable/disable

Temperature -40°C to +65°C / -40°F to +149°F (sensor dependent) Alarm 1 / 2 Relays: A1 / A2 Relays:
Normally de-energized Normally energized / de-energized
Humidity 20 to 90% RH non-condensing Non latching Latching / non latching
Alarm rising on gas reading Alarm on rising / falling
IP Rating NEMA 4X IP65 Alarm level 20% and 40% of scale Alarm level 10% to 90% of full scale
Hysteresis of 2% of scale
Options
Re-setting of Latched Relays Easily accessible interface on display (if used) or via HART interface (local or remote)
Form C and SPDT 3 Relays, 240 VAC, 5A (2 Alarm, 1 Fault) (Mutually exclusive with Modbus and Fieldbus Options)
Note Use of the Relay Module or ‘Other’ Communications Module (E.g. Foundation Fieldbus) is mutually exclusive. However, relay function may be used in conjunction
Power with standard communication output i.e. 4-20mA with HART.
Relay Specific Functions via Relay status information / Reset of latched conditions / Configuration of relays Forcing of relay state
18V to 32V (24V nominal)
HART Interface Reset through non intrusive User Interface. Remote Switch closure using Remote Reset input Remotely through HART
Hazardous Area Approvals (Pending) Foundation Fieldbus Module (Optional)
ATEX: Ex II 2 G D, EEx [ia] IIC T5 (Tamb -40°C to +65°C) Description Foundation Fieldbus compliant digital communications interface enables connection of the XNX transmitter to a multi-drop Foundation Fieldbus H1 network.
UL: Class I, Div 1, Groups B, C, and D / Class 1, Zone 1 AEx d IIC T5 (Tamb -40°C to +65°C) Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
CSA: Class I, Div 1, Groups B, C, and D T5 (Tamb -40°C to +65°C) Connections Sig+, Sig- and Screen
Performance Approvals EU – ATEX, EN45544, EN50104, EN50270, EN50271, EN13980, EN60079, EN60079-18, -1, -7, -29-1, EN45544-1, -2 Physical Layer Conforms to IEC 1158-2 and ISA 50.02, 31.25Kbits/s
(Pending) NA – UL 913, UL 1203, CSA 22.2 No. 152
Maximum No. of Nodes 32
Other – IEC61508 (SIL Assessment, SIL 2), IECEx OD 005
Functions Supported Gas Reading Detailed Sensor Information Including: Detailed Fault and Warning Information:
Gas Name and Units of measurement Optical Signal Level Fault and Alarm History
Display Module & User Interface (Standard) Instrument status (OK, warning, fault, over-range) Dynamic Reserve (Excel Only) Zero Calibration
General/Device Information Raw reading
Display Type Backlit LCD Remote zero and span calibration (detector dependent) 24V supply voltage
Temperature
Information Displayed Base Information: Gas Reading
RTC (Excel Only)
Gas Name and Units of measurement Calibration and Configuration status
Fault and Alarm Status Modbus RTU Module (Optional)
Large Numeric concentration or LEL display
Description The Modbus output module provides an Isolated RS485 output to enable the connection of the XNX transmitter to a multi-drop Modbus network
Bar graph showing current reading, set points and full scale.
Installation Fitted into housing base either at the factory or in the field by qualified service engineer.
Fault/Alarm and Security settings allow multi level operator access for set-up, configuration and calibration
Connections RS485+, RS485-, Drain
Operating Status Indication: Event history stores Time and Date of all Alarm, Diagnostic, Configuration events
Physical Layer Isolated RS485, 1200 to 19.2K Baud
Interface Magnetic wand with terminal screwdriver (supplied each unit)
Maximum No. of Nodes 254 XNX compatible transmitters only
4-20mA & HART (Standard Supply)
Protocol Modbus RTU
Description Fully configurable isolated 4-20mA & HART output module providing current sink, current source and isolated modes of operation. (supports HART 6.0 protocol) Functions Supported As per Foundation Fieldbus Module (Optional) - see above
Non-intrusive Interface Optional local IS port to enable HOT connection of a HART handheld configurator
Operating Modes Current sink / Current source / Isolated current sink /Conventional or with HART data Further information is available upon request.
Output Range 0 to 22mA * Foundation Fieldbus not available at time of publication. Please call your Honeywell Analytics sales person.
4-20mA Signal Accuracy +/- 1% FS XNXTM is a registered trademark of Honeywell International.
Max loop resistance 600 Ohms at 24Vdc loop supply HART® is a registered trademark of the HART Communication Foundation.
Functions Supported Gas Reading Detailed Sensor Information Including: RTC (Excel Only) MODBUS® is a registered trademark of Schneider Automation Inc.
via HART Gas Name and Units of measurement Optical Signal Level Calibration and Configuration status FoundationTM is a trademark of Fieldbus Foundation.
4-20mA signal level Dynamic Reserve (Excel Only) Detailed Fault and Warning Information
General/Device Information Raw reading Fault and Alarm History
Installation 24V supply voltage Zero Calibration
Configuration Temperature
Forcing of 4-20mA output
Local IS HART Port (Optional)
Description Provides externally accessible IS connections to the XNX transmitter to enable HOT connection of HC275/375 HART or equivalent hand held configurator.
Installation Fitted to one of the cable entries on the XNX transmitter.
Environmental Protection Terminals protected by cover to IP 66 when not in use
Honeywell Analytics Lines of Business

Commercial Industrial Portables


Vulcain-brand gas detection from stand- Renowned Sieger and Manning gas Single or multi-gas Lumidor and other
alone units to fully engineered, multi- detection systems with advanced premium detectors with compact,
point systems, all offering cost-effective electrochemical, infrared and open path lightweight designs ranging from
regulatory compliance sensing technologies simple alarm only units to advanced,
» Applications: parking structures, » Applications: oil and gas, cold storage, fully configurable and serviceable
chillers, mechanical rooms, office water/wastewater treatment, instruments
towers, commercial buildings, chemicals, engine rooms, plastics » Applications: underground utility
shopping centers, swimming pools, and fibers, agriculture, printing and and electricity ducts, boiler rooms,
golf courses, schools and universities, light industrial post-fire sites, sewers, industrial
laboratories plants, industrial hygiene, first
responder teams, remote fleets

Authorized Distributor:
GasDetectorsUSA.com
Houston, TX USA High Tech/Government Technical Services
832-615-3588 A complete portfolio of gas and chemical 24/7 global network includes
[email protected] detection instrumentation including post-sales service and Systems
infrared spectroscopy (MST) with no cross Integration teams
interference, to Chemcassette paper- » Emergency call out, service
based solutions (MDA Scientific) offering contracts, on/off-site repair, training
detection down to parts per billion and commissioning
» Applications: semiconductor » Complete range of spares,
manufacturing and nanotechnology, consumables and accessories
aerospace propulsion and safety,
specialty chemicals industry, research
laboratories, emergency response
HWA6181

Please Note:
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions.
Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations,
standards, and guidelines. This publication is not intended to form the basis of a contract.

H_XNX_DS01071_V1 9/08
© 2008 Honeywell Analytics