Model : SW-U801-WIN
OPERATION MANUAL
TABLE OF CONTENTS
1. INTRODUCTION.......................................................... 1
2. GENERAL SPECIFICATION............................................ 2
4. USING SW-U801-WIN.................................................. 5
4-1 SYSTEM SETUP...................................................... 5
4-2 CREATE NEW DATA FILE........................................ 5
4-3 ANGULAR DISPLAY................................................ 6
4-4 TEXT DISPLAY....................................................... 8
4-5 SYSTEM MONITOR................................................. 8
4-6 DATA QUERY......................................................... 8
1
2. GENERAL SPECIFICATIONS
System Computer with following operating system :
Requirement Win 98
Win 2000
XP
Monitor : VGA, EGA monitor
Common Port Select COM 1 to COM 8.
Function Data recorder, text display, analog display, chart
display, high/low limit, data query, text report,
chart report.
Data Record Auto or Manual
Sample Rate 2 to 3,600 seconds.
Data Save Data file : XXX.mdb.
* Automatic save to disk.
Data file : XXX.txt.
* When execute the " Print data " function, will
generate the xxx.text file.
Accessories CD disk................................. 1 PC.
Included Operation manual.................. 1 PC.
2
Optional RS232 cable, Model : UPCB-01
Accessory Direct RS232 cable be used to connect the meter
to the computer ( COM port ).
RS232 cable, Model : UPCB-02
Isolated RS232 cable be used to connect the
meter to the computer ( COM port ).
USB cable, Model : USB-01
USB interface cable be used to connect the meter
to the computer ( USB port ).
RS232 cable, Model : UPCB-04
* UPCB-04 is the double D9 RS232 cable.
* Available for FG-5000A-232, FG-20KG-232.
3
3-2 Star the program
Once you finish the installation, click the " Lutron801 "
from the program file to start the program.
UPCB-01
UPCB-02
USB-01
UPCB-04
4
4. USING SW-U801-WIN
4-1 System setup
After run the program & the computer will show the Fig. 1.
1. Chose System setup from the Setup menu in the top-left
corner and you will see a dialog box as Fig. 2
2. Enter a value in the " System Scan Rate " grid to determine
the sampling time.
3. Enter a value in the " Max Record Data " grid to determine
computer's max. recording number.
4. Click the arrow of " Common Port " to chose which port you
are connecting.
5. Click the arrow of " Text Display Type " to determine how
many displays will show in the Text display screen.
6. Click the arrow of " Angular Display Type " to determine
how many displays will show in the Angular display screen.
7 Click the up-down arrow of " Chart Display Chan. " to select
which channel will show in the Chart display screen.
8 To determine the meter with how many display.
9 Click " Save " to save your above setting then click " Exit " to
close this dialog box.
4-2 Create New Data File
Chose " Create New Data File " from the " Setup menu ( Fig. 3 )
1. Enter a file name in the Data File Name grid.
2. Click on " Create " then click on " Exit " to close this dialog.
5
4-3 Angular Display
We recommend you start from the " Angular Display " for serial
setting, and following instructions are based on the meter with 2
channels.
1. Select " Angular Display " from the commander line of
measurement system dialog box ( Fig. 1 ), and you will see the
Angular Display dialog box with four sheet.
The initial screen 2 Angular Display depending on your
selection of " System Setup " dialog box, Channel No.
Please refer to the highlight blue number at the
top-left corner of the angular panel.
2. Select " Page Setup " ( Fig-4 ) sheet for the proper range
setting of the angular panel and charts.
3. Select the up-down arrow of " Channel No " to determine
which channel that you want to adjust.
4. Enter a number of the " Min Value " and the " Max Value "
grid to determine the range of the angular panel.
5. Enter a number of the " Large Tick Delta " and " Small Tick
Delta " grid to determine the graduation of the angular panel.
6. Enter a number of " Label Delta " grid to determine the
numerical graduation of the angular panel.
7. Enter a number of " High Warning " and " Low Warning "
grid to set the tolerable range.
8. Input a integer in " Decimal " grid to determine how many
numbers behind the decimal point.
6
9. The number of the "Scale" grid must be an integer, and the
scale value will time your meter's reading value. For instance
scale is 10 and the meter's reading value is 65.4. The reading
value on the screen value would be 654.
10 To judge the unit of your measurement, please click the
grid in front of " Unit Auto Sense ".
11 Press " Save " button to save the setting.
Press Save button every time to make new
setting value work.
12 Change to sheet " Angular Display " ( Fig-5 ) you can find
the angular panel and inspect whether the setting is OK.
Panel Description
7
4-4 Text Display
1. Page setup sheet ( Fig-6 ).
Select the group that is suitable your measurement, and select
a channel for each display,
Change to "2 channel Display" sheet, you can see the setting
result.
2. Channel Display sheet ( Fig-7 )
The light blue grid shows the unit selected.
The Light orange grid shows the channel selected..
* Before make the data query, you should firstly select the
Database ( Chan. 1 to Chan. 8 ) and the sampling date.
* If user intend to have period data analysis, please check
the grid in front of the " Add Time condition ". Key in the
time in the " Start Time " and " END Time " grid.
8
1) Click the " Data Query " button, and each data would be listed
in the data list icon.
2) Click the " Show chart " button to show the data recorded with
chart display.
3) Click the " Print Chart " and " print Data " button to print the
detail of data recorded.
4) Click the " Clear Chart " button to clear the chart display.
5) * Enter the chart's header and in the " Header " grid.
* Enter the chart's footer and in the " Footer " grid.
* Enter numbers in " Y-Max " and " Y-Min " to set the Y-axsis.
* Enter numbers in " Y-Grid " and " X-Grid " to divide the chart
with vertical line and horizontal line and the numbers you
entered is the interval of two line.
6) Click on " Setup " button to display it on the chart.
7) Click Setup button every time when the setting value has been
changed to make a new setting value work.
8) Click "Exit" to close the program.