Sinchai Bhawan G+3 Patna.

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 13

BILL OF QUANTITY

Name of
Work :- SITC of Main Panel in place of Damaged Panel in Sinchai Bhawan (G+3), Patna.

Sl No. Description of Items Unit Qty Rate Amount


PART-A
1 SITC of Indoor cubicle extensible type compartmetalized Main
LT Panel, suitable for 415 V 50 Hz AC supply, suitable for 50 kA
short circuit rating, confirming to IP: 42 degree of protection,
made of 14SWG MS sheet floor mounted, dust & vermin proof
enclosure, having hinged cover on front and back having
neoprene gasket stuck to the doors, duly painted with 65-75
micron thick dry epoxy powder paint after 7 tank process of
degreasing, derusting etc comprising of the following
accessories complete with all interconnections with suitable
size of Electrical Grade Aluminum strip/hard drawn PVC
insulated copper cable i/c keeping the panel in position, minor
civil works as necessary, painting, sign writing etc complete as
required (as per Instruction of EIC) 1 set 3,878,067.00 3,878,067.00
INCOMING: -
A. 800A INCOMER FEEDER: QTY- 2NOS -
800A, ACB, 4 Poles, EDO Type, 50 kA, microprocessor based
1 release for LSIG protection. -
2 230V AC Under voltage release -
3 Breaker Control Switch(TNC) -
4 Auto-Manual Selector Switch -
5 Digital Multiffunction Meter, CL-1.0 -
6 R-Y-B Phase Indication Lamp -
7 On-Off-Trip Indication Lamp -
8 Current Transformer, 800/5A, 10VA CL-1.0 -
10 Single Phase Preventer with U/V & O/V Protection( ALVD2) -
11 On Delay Timer, 230V AC -
12 Aux. Contactor 2NO+2NC, 230V AC -
13 2A, SP, 10KA, MCB -
14 2A, FP, 10KA, MCB -
B. 630A INCOMER FEEDER : QTY- 1NO -
1 630A, ACB, 4 Poles, EDO Type, 50 kA, microprocessor based
release for LSIG protection. -
2 230V AC Under voltage release -
3 Breaker Control Switch(TNC) -
4 Auto-Manual Selector Switch -
5 Digital Multiffunction Meter, CL-1.0 -
6 R-Y-B Phase Indication Lamp -
7 On-Off-Trip Indication Lamp -
8 Current Transformer, 600/5A, 10VA CL-1.0 -
9 On Delay Timer, 230V AC -
10 Aux. Contactor 2NO+2NC, 230V AC -
11 2A, SP, 10KA, MCB -
12 2A, FP, 10KA, MCB -
C. 800A BUS-COUPLER FEEDER : QTY- 2NOS -
1 800A, ACB, 4 Poles, EDO Type, 50 kA, microprocessor based
without release. -
2 230V AC Under voltage release -
3 Breaker Control Switch(TNC) -
4 Auto-Manual Selector Switch -
5 On-Off-Trip Indication Lamp -
6 On Delay Timer, 230V AC -
7 Aux. Contactor 2NO+2NC, 230V AC -
8 2A, SP, 10KA, MCB -
BUS BAR: Bus Bar shall be enclosed in separate bus bar
chamber having screwed cover on front. Bus bar shall be
supported by DMC/SMC bus bar supports fixed at a distance
not more than 1.5 mtr between 2 sets of supports.

-
a) Horizontal Run: 800 amp 4 strip aluminum bar with 50%
neutral duly insulated with Heat shrinking sleeves in distinct
colour as reqd.
-
a)Vertical Run: 800 amp 4 strip aluminum bar with 50% neutral
duly insulated with Heat shrinking sleeves in distinct colour as
reqd.
-
OUTGOING: -
OUTGOING SECTION-I -
A. 630A OUTGOING FEEDER : QTY- 5 NOS -
1 630A, 4P, 36 kA, MCCB TMD Based with O/L & S/C Release 5 -
2 Spreader Link 10 -
3 Extended Rotary Handle 5 -
OUTGOING SECTION-II -
B. 630A OUTGOING FEEDER : QTY- 3 NOS -
1 630A, 4P, 36 kA, MCCB TMD Based with O/L & S/C Release 3 -
2 Spreader Link 6 -
3 Extended Rotary Handle 3 -
OUTGOING SECTION-III -
C. 630A OUTGOING FEEDER : QTY- 1 NOS -
1 630A, 4P, 36 kA, MCCB TMD Based with O/L & S/C Release 2 -
2 Spreader Link 4 -
3 Extended Rotary Handle 2 -
D. 320A OUTGOING FEEDER QTY. -1 NOS. -
1 320A, 4P, 36KA, MCCB TMD Based with O/L (70% to 100%) & 1
S/C Release -
2 Spreader Link 2 -
3 Extended Rotary Handle 1 -
E. 250A OUTGOING FEEDER QTY. -3 NOS. -
1 250A, 4P, 36KA, MCCB TMD Based with O/L (70% to 100%) & 3
S/C Release -
2 Spreader Link 6 -
3 Extended Rotary Handle 3 -
-
FEEDER PILAR -
2 SITC of Indoor cubicle extensible type compartmetalized
Feeder Pillar, suitable for 415 V 50 Hz AC supply, suitable
& CPRI certified for 70 kA short circuit rating, confirming
to & CPRI certified for IP: 42 degree of protection & CPRI
certified for temperature rise test, made of 16SWG MS
sheet floor mounted, dust & vermin proof enclosure,
having hinged cover on front and back having neoprene
gasket stuck to the doors, duly painted with 65-75 micron
thick dry epoxy powder paint after 7 tank process of
degreasing, derusting etc comprising of the following
accessories complete with all interconnections with
suitable size of Electrical Grade Copper strip/hard drawn
PVC insulated copper cable i/c keeping the panel in
position, minor civil works as necessary, painting, sign
writing etc complete as required (as per Instruction of
EIC) 1 set 316582.00 316,582.00
INCOMING: -
A. 320A INCOMER FEEDER: QTY- 1NO -
1 320A, 4P, 36 kA, MCCB TMD Based with O/L ( 70% to 100%) & S/C
Release -
2 Spreader Link -
3 Extended Rotary Handle -
4 3-Phase Digital Ammeter, CL-1.0 -
5 3-Phase Digital Voltmeter, CL-1.0 -
6 R-Y-B Phase Indication Lamp -
7 Current Transformer, 300/5A, 10VA CL-1.0 -
8 2A, SP, 10KA, MCB -
BUS BAR: Bus Bar shall be enclosed in separate bus
bar chamber having screwed cover on front. Bus bar
shall be supported by DMC/SMC bus bar supports
fixed at a distance not more than 1.5 mtr between 2
sets of supports.
-
400 amp 4 strip Copper bar with 50% neutral duly
insulated with Heat shrinking sleeves in distinct colour as
reqd.
-
OUTGOING: -
A. 100A OUTGOING FEEDER : QTY- 4 NOS -
100A, 4P, 25 kA, MCCB TMD Based with O/L ( 70% to 100%) & S/C
1 Release -
2 Spreader Link -
3 Extended Rotary Handle -
B. 63A OUTGOING FEEDER : QTY- 1 NO -
63A, 4P, 25 kA, MCCB TMD Based with O/L ( 70% to 100%)& S/C
1 Release -
2 Spreader Link -
3 Extended Rotary Handle -
3 SITC of Load Bank D/D Incomer 250A, FP MCCB, O/G FP - MCCB 1 Each
- 6 WAYS. -
S/F of CABLE ALLEY 1 Each -
S/F of METER MODULE 1 Each -
S/F of 250A/36KA/FP MCCB 1 Each -
S/F of SPREADER TERMINAL 2 Each -
S/F of 63A/25KA/FP MCCB 6 Each -
6 WAYS LOAD BANK 3 Set 164,440.00 493,320.00
4 Repacement of all existing main and sub distribution panel
after removal of cable both incoming and outgoing,
recovery of incoming cable as much as possible, doing
good to minor damages caused to the masonory work and
re connection of outgoing cable to the new panel etc ar
reqd. A special note to be made that the work shall be
carried out after office hour or on holidays only and it
must be ensured that there is no power disruption during
office hours. No extra payment shall be made in liue of
overtime etc.

1 job 100,000.00 100,000.00


5 DSR 9.2 Supplying and making outdoor end termination with cast resin
compound including aluminium lugs and other jointing
materials for following size of PVC insulated and PVC
sheathed /XLPE aluminium conductor cable of 1.1 KV grade as
required. -
9.2.20 3½ X 70 sq. mm 6 Each 1,565.00 9,390.00
9.2.21 3½ X 95 sq. mm 2 Each 1,694.00 3,388.00
9.2.26 3½ X 240 sq. mm 14 Each 2,655.00 37,170.00
9.2.28 3½ X 400 sq. mm 2 Each 3,362.00 6,724.00
6 4.2 Supplying and installing following size of perforated painted
with powder coating M.S. cable trays bends with perforation not
more than 17.5%,, joined with connectors, suspended from the
ceiling with M.S. suspenders including bolts & nuts, painting
suspenders etc as required.
-
4.2.4 300 mm width X 50 mm depth X 1.6 mm thickness 50 P/Mtr. 1,340.00 67,000.00
7 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE
power cable of 1.1 KV grade of following size direct in ground
including excavation, sand cushioning, protective covering and
refilling the trench etc. as required.
-
7.1.2 Above 35 sq. mm and upto 95 sq. mm 95 Metre 151.00 14,345.00
7.1.3 Above 95 sq. mm and upto 185 sq. mm 102 Metre 157.00 16,014.00
7.1.4 Above 185 sq. mm and upto 400 sq. mm 440 P/Mtr. 178.00 78,320.00
8 9.13 Providing , laying and fixing of following dia G.I. pipe (medium
class) in ground complete with G.I. fittings including trenching
(75 cm deep) and re-filling etc as required.
-
9.13.4 150 mm dia 50 P/Mtr. 1,626.00 81,300.00
9 3.21 Providing chemical/mineral maintenance free earthing system
comprising of copper coated earth electrode 3 metre length and
17.2 mm outer dia along with 25 kg earth conductivity
enhancing back fill mineral compound for earth electrode to fill
up the excavated earth and earth inspection pit etc. as required.
5 Set 16,586.00 82,930.00
10 3.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in
recess for connections etc. as required.
60 Metre 1,032.00 61,920.00
11 Supply and fixing Carbon dioxide fire extinguishers of 4.5 kg
capacity each as per IS : 2878-1976 and mounting the same on
wall by means of suitable hooks.
10 Each 6,000.00 60,000.00
12 M/R S/F of 12mm chequred Rubber Sheet as reqd. 4,202.00
6 P/Roll 25,212.00
13 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FR PVC insulated copper conductor
single core cable in surface / recessed medium class PVC
conduit with modular switch , modular plate, suitable size G.I.
box etc as required. -
1.3.3 Group C 14 Point 724.00 10,136.00
14 1.7 Wiring for circuit/ submain wiring alongwith earth wire with
the following sizes of FR PVC insulated copper conductor, single
core cable in surface/ recessed medium class PVC conduit as
required. -
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 100 Meter 130.00 13,000.00
1.7.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 8 Meter 271.00 2,168.00
15 1.5 Wiring for light/ power plug plug with 2 X 4 sq. mm FR PVC
insulated copper conductor single core cable in surface /
recessed medium class PVC conduit along with 1 Nos 4 sq. mm
FR PVC insulated copper conductor single core cable for loop
earthing as required.
30 Meter 200.00 6,000.00
16 1.31 Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess including providing and
fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps
modular switch, connection etc. as required.
2 Each 362.00 724.00
17 1.32 Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess including providing and
fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16
amps modular switch, connection etc. as required.
3 Each 413.00 1,239.00
18 2.8 Supplying and fixing following way single pole & neutral, sheet
steel, MCB distribution board, 240 volts, on surface/ recess,
complete with tinned copper bus bar, neutral bus-bar, earth bar,
din bar, interconnections, powder painted including earthing
etc. as required. (But without MCB/RCCB/Isolator)
-
2.8.7 2 + 6 way, Double door 1 Each 1,081.00 1,081.00
19 8.11.4 Supply and installation of 300 mm, 230 v A.C. exhaust fan in the
existing opening including making good the damage, connection
testing, commissioning etc as required.
2 Each 1,483.00 2,966.00
20 8.11.2 Supply and installation of regular/standard model A.C. ceiling
fan of 1200 mm sweep including wiring the down rods of
standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated
copper conductor etc as required.
2 Each 1,618.00 3,236.00
21 5.9.3 Supplying and fixing single wall mounted 18/22 watt LED type
batten fitting complete with electronic driver and LED tube etc
directly on wall/ ceiling including connections with 1.5 sq.mm
FR PVC insulated copper conductor and earthing the body etc. as
required. 6 Each 684.00 4,104.00
22 1.33 Supplying and fixing 2 pin, 6 amp ceiling rose on the existing
junction box/ wooden block including connection etc as 10 Each 42.00 420.00
required.
23 5.12.5 Supplying and fixing 40/45 watt LED type street light with die
cast aluminium housing for ingress protection of IP65 and
complete with all accessories etc, on pole/building including
connection with FR PVC insulated copper conductor cable and
earthing the body etc. as required.
4 Each 4,056.00 16,224.00
24 8.4 Supplying and embedding following dia G.I. pipe (medium class)
in pole collar/ foundation (during casting) for cable entry
including bending the pipe to the required shape complete as
required. -
8.4.2 40 mm dia 4 Meter 390.00 1,560.00
25 AR-1 Supply of following sizes and core PVC/XLPE insulated, PVC
sheathed armoured electrical cable with aluminium conductor
for working voltage upto 1.1 KV etc as required.
-
400 sq. mm., 3.5 core (Including Proposed Parking Building)
(one no. Stand by) 520 P/Mtr. 1,648.00
856,960.00
TOTAL Rs. 6,251,500.00
PART-B
26 SITC of Load Bank D/D Incomer 400A, FP MCCB, O/G FP - MCCB 1 Each
- 8 WAYS . -
S/F of CABLE ALLEY 1 Each -
S/F of METER MODULE 1 Each -
S/F of 400A/36KA/FP MCCB 1 Each -
S/F of SPREADER TERMINAL 2 Each -
S/F of 125A/25KA/FP MCCB 8 Each -
8 WAYS LOAD BANK 3 Set 219,354.00 658,062.00
27 SITC of Load Bank D/D Incomer 400A, FP MCCB, O/G FP - MCCB 1 Each
- 12 WAYS. -
S/F of CABLE ALLEY 1 Each -
S/F of METER MODULE 1 Each -
S/F of 400A/36KA/FP MCCB 1 Each -
S/F of SPREADER TERMINAL 2 Each -
S/F of 63A/25KA/FP MCCB 12 Each -
12 WAYS LOAD BANK 4 Set 269,446.00 1,077,784.00
28 AR-1 Supply of following sizes and core PVC/XLPE insulated, PVC
sheathed armoured electrical cable with aluminium conductor
for working voltage upto 1.1 KV etc as required.
-
240 sq. mm., 3.5 core (For 400A Load Bank 7 Nos.) 460 P/Mtr. 1,056.00 485,760.00
70 sq. mm., 3.5 core (For 250A Load Bank 3 Nos.) 310 p/mtr. 376.00 116,560.00
95 sq. mm., 3.5 core (For Feeder Pilar) 125 p/mtr. 455.00 56,875.00
29 2.9 Supplying and fixing following way, horizontal type three pole &
neutral, sheet steel, MCB distribution board, 415 volts, on
surface/ recess, complete with tinned copper bus - bar, neutral
bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without
MCB/RCCB/Isolator)
-
2.9.5 6 way ( 4 + 18 ), double door, horizontal type 11 Each 2,905.00 31,955.00
30 2.8 Supplying and fixing following way single pole & neutral, sheet
steel, MCB distribution board, 240 volts, on surface/ recess,
complete with tinned copper bus bar, neutral bus-bar, earth bar,
din bar, interconnections, powder painted including earthing
etc. as required. (But without MCB/RCCB/Isolator)
-
2.8.12 12 way, Double door 4 Each 1,574.00 6,296.00
2.8.13 14/16 way, Double door 1 Each 1,936.00 1,936.00
31 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive loads of
following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
-
2.12.1 6/32 amps, Single pole 234 Each 192.00 44,928.00
2.12.7 50/63 amps, Tripole pole and neutral 11 Each 1,635.00 17,985.00
32 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive loads of
following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
-
2.13.2 40 amps, Double pole 24 Each 805.00 19,320.00
2.13.3 50/63 amps, Double pole 2 Each 919.00 1,838.00
33 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FR PVC insulated copper conductor
single core cable in surface / recessed medium class PVC
conduit with modular switch , modular plate, suitable size G.I.
box etc as required. -
1.3.3 Group C 32 Point 724.00 23,168.00
34 1.7 Wiring for circuit/ submain wiring alongwith earth wire with
the following sizes of FR PVC insulated copper conductor, single
core cable in surface/ recessed medium class PVC conduit as
required. -
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 96 Meter 130.00 12,480.00
1.7.5 2 X 10 sq. mm + 1 X 10 sq. mm earth wire 80 Meter 382.00 30,560.00
1.7.13 4 X 16 sq. mm + 1 X 16 sq. mm earth wire 480 Meter 879.00 421,920.00
35 1.5 Wiring for light/ power plug plug with 2 X 4 sq. mm FR PVC
insulated copper conductor single core cable in surface /
recessed medium class PVC conduit along with 1 Nos 4 sq. mm
FR PVC insulated copper conductor single core cable for loop
earthing as required.
30 Meter 200.00 6,000.00
36 1.31 Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess including providing and
fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps
modular switch, connection etc. as required.
1 Each 362.00 362.00
37 1.32 Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess including providing and
fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16
amps modular switch, connection etc. as required.
2 Each 413.00 826.00
38 8.11.4 Supply and installation of 300 mm, 230 v A.C. exhaust fan in the
existing opening including making good the damage, connection
testing, commissioning etc as required.
1 Each 1,483.00 1,483.00
39 8.11.2 Supply and installation of regular/standard model A.C. ceiling
fan of 1200 mm sweep including wiring the down rods of
standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated
copper conductor etc as required.
1 Each 1,618.00 1,618.00
40 5.9.3 Supplying and fixing single wall mounted 18/22 watt LED type
batten fitting complete with electronic driver and LED tube etc
directly on wall/ ceiling including connections with 1.5 sq.mm
FR PVC insulated copper conductor and earthing the body etc. as
required. 2 Each 684.00 1,368.00
41 1.33 Supplying and fixing 2 pin, 6 amp ceiling rose on the existing
junction box/ wooden block including connection etc as 4 Each 42.00 168.00
required.
42 3.21 Providing chemical/mineral maintenance free earthing system
comprising of copper coated earth electrode 3 metre length and
17.2 mm outer dia along with 25 kg earth conductivity
enhancing back fill mineral compound for earth electrode to fill
up the excavated earth and earth inspection pit etc. as required.
2 Set 16,586.00 33,172.00
43 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in
recess for loop earthing etc. as required.
50 Metre 116.00 5,800.00
1st Floor -
44 2.9 Supplying and fixing following way, horizontal type three pole &
neutral, sheet steel, MCB distribution board, 415 volts, on
surface/ recess, complete with tinned copper bus - bar, neutral
bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without
MCB/RCCB/Isolator)
-
2.9.5 6 way ( 4 + 18 ), double door, horizontal type 18 Each 2,905.00 52,290.00
45 2.8 Supplying and fixing following way, horizontal type three pole &
neutral, sheet steel, MCB distribution board, 415 volts, on
surface/ recess, complete with tinned copper bus - bar, neutral
bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without
MCB/RCCB/Isolator)
-
2.9.4 4 way ( 4 + 12 ), double door, horizontal type 18 Each 2,388.00 42,984.00
46 2.10 Supplying and fixing following ways, surface/ recess mounting,
vertical type, 415 volts, TPN MCB distribution board of sheet
steel, dust protected, duly powder painted, inclusive of 200 amp
tinned copper bus bar, common neutral link, earth bar, din bar,
for mounting MCB's (but without MCB's and incomer) as
required. (Note : Vertical type MCB TPDB is normally used
where 3 phase outlets are required.)
-
2.10.4 4 way ( 8 + 12 ), Double door, Vertical type 1 Each 6,321.00 6,321.00
47 2.4 Providing and fixing following rating and breaking capacity
MCCB in existing cubicle panel board including drilling holes in
cubicle panel, making connections etc. as required.
-
2.4.3 125 Amp, 16 KA 1 Each 4,004.00 4,004.00
48 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive loads of
following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
-
2.12.1 6/32 amps, Single pole 492 Each 192.00 94,464.00
2.12.7 50/63 amps, Tripole pole and neutral 48 Each 1,635.00 78,480.00
49 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive loads of
following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
-
2.13.2 40 amps, Double pole 24 Each 805.00 19,320.00
50 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FR PVC insulated copper conductor
single core cable in surface / recessed medium class PVC
conduit with modular switch , modular plate, suitable size G.I.
box etc as required. -
1.3.3 Group C 28 Point 724.00 20,272.00
51 1.7 Wiring for circuit/ submain wiring alongwith earth wire with
the following sizes of FR PVC insulated copper conductor, single
core cable in surface/ recessed medium class PVC conduit as
required. -
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 84 Meter 130.00 10,920.00
1.7.15 4 X 35 sq. mm + 1 X 16 sq. mm earth wire 55 Meter 1,587.00 87,285.00
1.7.13 4 X 16 sq. mm + 1 X 16 sq. mm earth wire 1008 Meter 879.00 886,032.00
52 1.5 Wiring for light/ power plug plug with 2 X 4 sq. mm FR PVC
insulated copper conductor single core cable in surface /
recessed medium class PVC conduit along with 1 Nos 4 sq. mm
FR PVC insulated copper conductor single core cable for loop
earthing as required.
30 Meter 200.00 6,000.00
53 1.31 Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess including providing and
fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps
modular switch, connection etc. as required.
1 Each 362.00 362.00
54 1.32 Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess including providing and
fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16
amps modular switch, connection etc. as required.
2 Each 413.00 826.00
55 8.11.4 Supply and installation of 300 mm, 230 v A.C. exhaust fan in the
existing opening including making good the damage, connection
testing, commissioning etc as required.
1 Each 1,483.00 1,483.00
56 8.11.2 Supply and installation of regular/standard model A.C. ceiling
fan of 1200 mm sweep including wiring the down rods of
standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated
copper conductor etc as required.
1 Each 1,618.00 1,618.00
57 5.9.3 Supplying and fixing single wall mounted 18/22 watt LED type
batten fitting complete with electronic driver and LED tube etc
directly on wall/ ceiling including connections with 1.5 sq.mm
FR PVC insulated copper conductor and earthing the body etc. as
required. 2 Each 684.00 1,368.00
58 1.33 Supplying and fixing 2 pin, 6 amp ceiling rose on the existing
junction box/ wooden block including connection etc as
required. 4 Each 42.00 168.00
59 3.21 Providing chemical/mineral maintenance free earthing system
comprising of copper coated earth electrode 3 metre length and
17.2 mm outer dia along with 25 kg earth conductivity
enhancing back fill mineral compound for earth electrode to fill
up the excavated earth and earth inspection pit etc. as required.
2 Set 16,586.00 33,172.00
60 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in
recess for loop earthing etc. as required.
50 Metre 116.00 5,800.00
2nd Floor -
61 2.9 Supplying and fixing following way, horizontal type three pole &
neutral, sheet steel, MCB distribution board, 415 volts, on
surface/ recess, complete with tinned copper bus - bar, neutral
bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without
MCB/RCCB/Isolator)
-
2.9.5 6 way ( 4 + 18 ), double door, horizontal type 16 Each 2,905.00 46,480.00
2.9.4 4 way ( 4 + 12 ), double door, horizontal type 10 Each 2,388.00 23,880.00
62 2.10 Supplying and fixing following ways, surface/ recess mounting,
vertical type, 415 volts, TPN MCB distribution board of sheet
steel, dust protected, duly powder painted, inclusive of 200 amp
tinned copper bus bar, common neutral link, earth bar, din bar,
for mounting MCB's (but without MCB's and incomer) as
required. (Note : Vertical type MCB TPDB is normally used
where 3 phase outlets are required.)
-
2.10.4 4 way ( 8 + 12 ), Double door, Vertical type 1 Each 6,321.00 6,321.00
63 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive loads of
following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
-
2.12.1 6/32 amps, Single pole 360 Each 192.00 69,120.00
2.12.7 50/63 amps, Tripole pole and neutral(28+12) 40 Each 1,635.00 65,400.00
64 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive loads of
following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
-
2.13.2 40 amps, Double pole 30 Each 805.00 24,150.00
65 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FR PVC insulated copper conductor
single core cable in surface / recessed medium class PVC
conduit with modular switch , modular plate, suitable size G.I.
box etc as required. -
1.3.3 Group C 25 Point 724.00 18,100.00
66 1.7 Wiring for circuit/ submain wiring alongwith earth wire with
the following sizes of FR PVC insulated copper conductor, single
core cable in surface/ recessed medium class PVC conduit as
required. -
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 75 Meter 130.00 9,750.00
1.7.13 4 X 16 sq. mm + 1 X 16 sq. mm earth wire 784 Meter 879.00 689,136.00
1.7.15 4 X 35 sq. mm + 1 X 16 sq. mm earth wire 45 Meter 1,587.00 71,415.00
67 1.5 Wiring for light/ power plug plug with 2 X 4 sq. mm FR PVC
insulated copper conductor single core cable in surface /
recessed medium class PVC conduit along with 1 Nos 4 sq. mm
FR PVC insulated copper conductor single core cable for loop
earthing as required.
30 Meter 200.00 6,000.00
68 1.31 Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess including providing and
fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps
modular switch, connection etc. as required.
1 Each 362.00 362.00
69 1.32 Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess including providing and
fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16
amps modular switch, connection etc. as required.
2 Each 413.00 826.00
70 8.11.4 Supply and installation of 300 mm, 230 v A.C. exhaust fan in the
existing opening including making good the damage, connection
testing, commissioning etc as required.
1 Each 1,483.00 1,483.00
71 8.11.2 Supply and installation of regular/standard model A.C. ceiling
fan of 1200 mm sweep including wiring the down rods of
standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated
copper conductor etc as required.
1 Each 1,618.00 1,618.00
72 5.9.3 Supplying and fixing single wall mounted 18/22 watt LED type
batten fitting complete with electronic driver and LED tube etc
directly on wall/ ceiling including connections with 1.5 sq.mm
FR PVC insulated copper conductor and earthing the body etc. as
required. 2 Each 684.00 1,368.00
73 1.33 Supplying and fixing 2 pin, 6 amp ceiling rose on the existing
junction box/ wooden block including connection etc as 4 Each 42.00 168.00
required.
74 3.21 Providing chemical/mineral maintenance free earthing system
comprising of copper coated earth electrode 3 metre length and
17.2 mm outer dia along with 25 kg earth conductivity
enhancing back fill mineral compound for earth electrode to fill
up the excavated earth and earth inspection pit etc. as required.
2 Set 16,586.00 33,172.00
75 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in
recess for loop earthing etc. as required.
50 Metre 116.00 5,800.00
76 2.4 Providing and fixing following rating and breaking capacity
MCCB in existing cubicle panel board including drilling holes in
cubicle panel, making connections etc. as required.
-
2.4.3 125 Amp, 16 KA 1 Each 4,004.00 4,004.00
3rd Floor -
77 2.9 Supplying and fixing following way, horizontal type three pole &
neutral, sheet steel, MCB distribution board, 415 volts, on
surface/ recess, complete with tinned copper bus - bar, neutral
bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without
MCB/RCCB/Isolator)
-
2.9.4 4 way ( 4 + 12 ), double door, horizontal type 18 Each 2,388.00 42,984.00
2.9.5 6 way ( 4 + 18 ), double door, horizontal type 18 Each 2,905.00 52,290.00
78 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive loads of
following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
-
2.12.1 6/32 amps, Single pole 508 Each 192.00 97,536.00
2.12.7 50/63 amps, Tripole pole and neutral 34 Each 1,635.00 55,590.00
79 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve,
miniature circuit breaker suitable for inductive loads of
following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
-
2.13.2 40 amps, Double pole 10 Each 805.00 8,050.00
80 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FR PVC insulated copper conductor
single core cable in surface / recessed medium class PVC
conduit with modular switch , modular plate, suitable size G.I.
box etc as required. -
1.3.3 Group C 45 Point 724.00 32,580.00
81 1.7 Wiring for circuit/ submain wiring alongwith earth wire with
the following sizes of FR PVC insulated copper conductor, single
core cable in surface/ recessed medium class PVC conduit as
required. -
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 135 Meter 130.00 17,550.00
1.7.13 4 X 16 sq. mm + 1 X 16 sq. mm earth wire 1008 Meter 879.00 886,032.00
82 1.5 Wiring for light/ power plug plug with 2 X 4 sq. mm FR PVC
insulated copper conductor single core cable in surface /
recessed medium class PVC conduit along with 1 Nos 4 sq. mm
FR PVC insulated copper conductor single core cable for loop
earthing as required.
30 Meter 200.00 6,000.00
83 1.31 Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess including providing and
fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps
modular switch, connection etc. as required.
1 Each 362.00 362.00
84 1.32 Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess including providing and
fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16
amps modular switch, connection etc. as required.
2 Each 413.00 826.00
85 8.11.4 Supply and installation of 300 mm, 230 v A.C. exhaust fan in the
existing opening including making good the damage, connection
testing, commissioning etc as required.
1 Each 1,483.00 1,483.00
86 8.11.2 Supply and installation of regular/standard model A.C. ceiling
fan of 1200 mm sweep including wiring the down rods of
standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated
copper conductor etc as required.
1 Each 1,618.00 1,618.00
87 5.9.3 Supplying and fixing single wall mounted 18/22 watt LED type
batten fitting complete with electronic driver and LED tube etc
directly on wall/ ceiling including connections with 1.5 sq.mm
FR PVC insulated copper conductor and earthing the body etc. as
required. 2 Each 684.00 1,368.00
88 1.33 Supplying and fixing 2 pin, 6 amp ceiling rose on the existing
junction box/ wooden block including connection etc as 4 Each 42.00 168.00
required.
89 3.21 Providing chemical/mineral maintenance free earthing system
comprising of copper coated earth electrode 3 metre length and
17.2 mm outer dia along with 25 kg earth conductivity
enhancing back fill mineral compound for earth electrode to fill
up the excavated earth and earth inspection pit etc. as required.
2 Set 16,586.00 33,172.00
90 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in
recess for loop earthing etc. as required.
50 Metre 116.00 5,800.00
91 5.9.3 Supplying and fixing single wall mounted 18/22 watt LED type
batten fitting complete with electronic driver and LED tube etc
directly on wall/ ceiling including connections with 1.5 sq.mm
FR PVC insulated copper conductor and earthing the body etc. as
required. 20 Each 684.00 13,680.00
Total Amount 6,747,035.00

Less Dismentelled@2% 134,940.70

PART-B 6,612,094.30

PART-A 6,251,500.00

SUM OF PART-A + PART-B 12,863,594.30

Say Rs.1,28,63,594.00

Elect.Executive Engineer,
Elect. Works Div.No.3,
B.C.Deptt.,Patna.
0.18