Load Calculation On Selected Column of Frame
Load Calculation On Selected Column of Frame
428571429
Floor Tributary scaled Area surrounded by column in the selected frame
Length (scaled) of beam within the scaled Tributary area of the columns in the selected frame
Length (scaled) of infill walls within the scaled Tributary area of the columns in the selected frame
Thickness of slab = 6"
Concrete density
Size of Beam = 250 x 350 mm
Size of Column = 250 x 250 mm
Height of story
Live load on Roof As per Pakistan Building Code (PBC) 2007
Live load on Floor As per Pakistan Building Code (PBC) 2007
Floor Finishing load As per Pakistan Building Code (PBC) 2007
3m
1.2 kN/m^2 As per UBC/PBC2007
2.4 kN/m^2 As per UBC/PBC2007
1.72 kN/m^2 As per UBC/PBC2007
1.2 kN/m^2
3.75 kN/m^2
1.72 kN/m^2
0.8 kN/m^2
6.27 kN/m^2
9.444 kN/m^2 Same load factors used as per ACI318-14 normal design practice in Pakistan
2.4 kN/m^2
3.75 kN/m^2
1.72 kN/m^2
5.47 kN/m^2
10.404 kN/m^2
1.855 m
18.5 kN/m^3
0.23 m
7.893025 kN/m
9.47163 kN/m Same load factors used as per ACI318-14 normal design practice in Pakistan
2.1875 kN/m
2.625 kN/m Same load factors used as per ACI318-14 normal design practice in Pakistan
1.5625 kN/m
1.875 kN/m Same load factors used as per ACI318-14 normal design practice in Pakistan
46.2756 kN
10.10625 kN
36.4657755 kN
92.8476255 kN
50.9796 kN
10.10625 kN
36.4657755 kN
97.5516255 kN
190.399251 kN
50.9796 kN
10.10625 kN
36.4657755 kN
11.8125 kN
109.3641255 kN
299.7633765 kN
e in Pakistan
e in Pakistan
e in Pakistan
e in Pakistan