UL Certificate
UL Certificate
CLIENT INFORMATION
Company Name SmartBond Chemicals Pvt Ltd
Address 92A, shiv Vihar , opp Vishwakarma industrial area road no. 5, Murlipura
Jaipur, Rajasthan, 302013
India
AUDIT INFORMATION:
Description of Tests Per Standard UL 94 Edition 6th June 27, 2020
No. CSA C22.2 /Revisi 2nd Oct 2000 (R 2018)
No.0.17-00 on Date
[] Tests Conducted by +
Printed Name Signature
[]UL Staff witnessing
testing (WTDP only)
[]Authorized Signatory Printed name Signature, and include date for
(CTDP, TPTDP, TCP) CTDP, TPTDP, TCP
Reviewed and accepted
by qualified Project
Handler
Printed Name Signature
TESTS TO BE CONDUCTED:
Test [] Comments/Parameters
No. Done Test Name [x]Tests Conducted by ++
1 X HORIZONTAL BURNING TEST; HB MADDUX CHEN 2021-03-15
Instructions -
+ - When all tests are conducted by one person, printed name and signature
can be inserted here instead of including printed name and signature on each
page containing data. Must indicate number of pages in the data package.
++ - When test conducted by more than one person, printed name and signature
of person conducting the test can be inserted next to the test name instead
of including printed name and signature on each page containing data. Must
indicate number of pages in the data package.
Special Instructions -
[X] Unless specified otherwise in the individual Methods, the tests shall be
conducted under the following ambient conditions. Confirmation of these
conditions shall be recorded at the time the test is conducted.
Note to Lab:
Please refer the below mentioned LPGs as applicable, before conducting the
test
00-LO-L0884- LPG for UL94 50W and 500 W Vertical Burning Test Flame
Confirmation Procedure
00-LO-L0924- LPG For Glow wire series (GWEPT, GWFI, GWIT) of Tests in IEC
60695-2-10, -11, -12, and -13
TEST LOCATION:
[X]UL or Affiliate []WTDP []CTDP []OTHER
Company Name Underwriters Laboratories Taiwan Co., LtdUL
Address 1st Fl, 260 Da-Yeh Road, Peitou, Taipei City, Taiwan 112
+ - If Test Number is used, the Test Number must be identified on the data
sheet pages or on the Data Sheet Package cover page.
Inst.
ID No. Make/Model/Serial Number/Asset No.
+ - If the Test Number is used, then the Test Number or Numbers the sample
was used in must be identified on the data sheet pages or on the Data Sheet
Package cover page.
[] Sampling Procedure –
Chamber setting(s) [was] [were] monitored to ensure that the setting(s) [was]
[were] stable throughout the test time frame. Any deviations from the
setting(s) are noted below.
M.W
2021-03-11
Burning
Specimen Thickness Damaged Rate Flame
No. mm Time, t (s) Length, L (mm) X1 (mm/min) Class
HB
Set #: 1 Material: SL-1000 IN (1.9 mm) Color: WT
Test Date: 2021-03-15 09:00 [X] Yes
1 1.904 0 0 ( 2 ) -
2 1.991 0 0 ( 2 ) -
3 1.975 0 0 ( 2 ) -
HB
Set #: 2 Material: SL-1000 IN (3.2 mm) Color: WT
Test Date: 2021-03-15 09:10 [X] Yes
1 3.428 0 0 ( 2 ) -
2 3.370 0 0 ( 2 ) -
3 3.435 0 0 ( 2 )
Set #: HB
Material: Color:
Test Date: [ ] Yes
1 ( )
2 ( )
3 ( )
HB
Set #: Material: Color:
Test Date: [ ] Yes
1 ( )
2 ( )
3 ( )
Note: Damaged Length (L) equals distance beyond 25 mm reference mark M.C
Linear Burning Rate = 60L/t (Not calculated if 25 mm mark not passed) 2021-03-15
Observation (X1):
(1) Ceased to burn before the 100 mm reference mark. Specimen is HB
(2) Ceased to burn before the 25 mm reference mark. Specimen is HB
(3) Misc:
Lab Ambient: 21 °C (25±10°C) and 64 %RH (< 75% RH)