Capa - 2
Capa - 2
SQA/QAF/01
Supplier Name DEAKIN WIRE INDUSTRIES Qty. Rejected Havells Plant IQC
1455.100 KGS.
Level 1 Response (To respond within 24hrs. Of receipt of notification )
Establish Team Defect Description
Name Dept. Contact No. AS PER HAVELLS CHECKED 5 SAMPLES IN LOT, FOUND 2 SAMPLES OD HIGH.
Harvir Singh Plant Head 7088000384
Aman Verma Production Head 7088000381
Vikas Kumar Saini Quality Manager 9389926561
Bhanu Partap Quality Inspector 7985972550
Why ? Overall diameter higher side, because operator not checked Why ? QC inspector not properly checked Overall Diameter.
properly on running lines.
Why ? Why ?
Why ? Why ?
Why ? Why ?
Action plan
Root Cause Action Responsibility Target Date Status
Machine Operator checked and verify by supervisor spool to spool. Prod./Quality Immediate OK
Occurrence
Given On Job Training to QC inspector and other concern person, Each and every spools Quality Manager Immediate OK
checked and recorded in QC registor