ACU+ CONTROLLER

M820B, M821B, M820D, M821D, M820N

Designed for global use, the ACU+ Controller with stands


KEY FEATURES
high telecom standards, providing outstanding reliability
yy Flexible and scalable and availability.
to satisfy your present
and future needs
with configurable IB Description
(interface boards)
The ACU+ is an advanced control unit
yy Easily configurable file designed for DC power applications. It can
upload/download minimizes provide remote monitoring of the telecom
installation time site's AC mains supply, DC power plant,
yy Long battery battery backup, diesel generator and site
life-span – sophisticated environment etc. M820B
M821B
boost charge management Featuring advanced battery management
such as sophisticated boost charge
yy Unattended battery
control, remaining time and capacity
test – advanced scheduled
prediction, constant current test,
test/constant test/fast test
scheduled test and short test, and Battery
yy High quality failure Low Voltage Disconnection (BLVD),
information – programmable the ACU+ realizes easy and predictive
logic controller provides battery maintenance. Furthermore, with
intelligent alarm setup basic energy saving and power split
function, the ACU+ is a highly
yy Lower operating cost-efficient product. M820D
M821D
cost – energy-saving
The information and alarms from a
standby function
specific site can be monitored or checked
for rectifier
with a simple web browser or special
monitoring software. When using a web
browser, no additional software is needed,
and the web browser login is
password protected.

M820N

1
ACU+ CONTROLLER

Technical Specifications Diagram


GENERAL IE ENEC
Power Supply 19 VDC to 60 VDC SNMP HTTP TCP
Power Consumption 5W
Operating
-40°C to +75°C / -40°F to +167°F
Temperature Range TCP/IP PSTN,GSM
Relative Humidity 0 to 90%
EMC EN 300 386, 2001 class B, FCC part 15 class B MODEM

Safety IEC 60950-1, EN 60950-1, UL 60950-1 DC POWER RS232

Approvals CE, UL and NEBS level 3 ACU+ USB


memory stick
CAN I2C RS485
MECHANICAL DATA
PSU PSU PSU SM conv IB1 EIB SM Large
42 x 86.6 x 211.5 (mm) / DU or IB2 Modules DU
M820B and M821B:
Dimensions 1.65 x 3.41 x 8.33 (inches)
(H x W x D) 86.6 x 86.8 x 211.5 (mm) / Network Operation Center (NOC)
M820D, M821D and M820N:
3.41 x 3.42 x 8.33 (inches)
NOC ABBREVIATIONS
Standard Installation
Hot pluggable in stand-alone or embedded power plants Public Switched Telephone Network,
Methods PSTN
an ordinary telephone line
Weight < 1 kg / 2.2 Ibs
IE Internet Explorer
EnergyMaster™ Vertiv Energy Center,
INPUTS/OUTPUTS multi-platform, multi-user, distributed
ENEC multi- language web environment
Model M820B M821B M820D M821D M820N
for monitoring of Vertiv DC, HPAC
Display LCD with 8 x 16 characters LCD with 4 x 16 characters and UPS equipment

RS232, 10/100M Power Supply Unit


PSU
Communication RS232, RS485, Ethernet, USB Ethernet, TCP/IP, (AC/DC converter/rectifier)
SNMP, web server
Supervision Module for additional alarms
SM DU
Protocol HTTP, SNMP, EEM, SocTpe, Rsoc in extension cabinets

2 battery EIB Extension Interface Board IB


2 battery currents, currents, IB Interface Board
3 DC system
1 load current, 1 load
voltages, 3 DC
1 bus voltage, current, Refer Refer
Analog system currents,
2 battery voltages, 1 bus voltage, to M820B to M821B
3 temperatures, 2 battery
3 temperatures, Ordering Information
3 AC voltages
3 AC voltages voltages,
2 temperatures MODEL PRODUCT CODE / DESCRIPTION
Inputs
M820B 1M820BAXX / ACU+ controller
1 input for status of
SPD auxiliary 1 input for M821B 1M821BAXX / ACU+ controller
contacts, 1 input status of SPD
Refer Refer M820D 1M820DAXX / ACU+ controller
Digital 10 load fuses, for status of SPD auxiliary contacts
to M820B to M821B
4 battery fuses, auxiliary contacts 10 load fuses, 4 M821D 1M821DAXX / ACU+ controller
bi-stable battery fuses
contactor status M820N 1M820NXX / ACU+ controller
MODEL OPTIONAL INTERFACE BOARD
2 LVD mono Refer Refer 2 LVD mono &
Outputs None
& bistable contactors to M820B to M821B bistable contactors IB1 4 relay outputs, 4 digital inputs
IB2 8 relay outputs, 8 digital inputs,
EXAMPLES OF ALARMS 2 temperatures

DC Power Plant AC mains failure, rectifier failure, DC/DC converter failure, high voltage shutdown, EIB 5 relay outputs, 8DC voltages,
Alarms fan failure, thermal derating (of rectifier output due to high temperature) 3DC currents, 2 temperatures

VertivCo.com | Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA