This document provides specifications for multiple air conditioning models including the GMV-ND28T/C-T, GMV-ND100T/C-T, GMV-ND160T/C-T, and GMV-ND56T/C-T. It includes information on noise levels, electrical specifications, refrigerant type, dimensions, weights and other technical details. Key specifications listed are cooling and heating capacity, airflow, power consumption, pipe diameters and electrical requirements. Units of measurement are provided in both metric and imperial systems.
This document provides specifications for multiple air conditioning models including the GMV-ND28T/C-T, GMV-ND100T/C-T, GMV-ND160T/C-T, and GMV-ND56T/C-T. It includes information on noise levels, electrical specifications, refrigerant type, dimensions, weights and other technical details. Key specifications listed are cooling and heating capacity, airflow, power consumption, pipe diameters and electrical requirements. Units of measurement are provided in both metric and imperial systems.
This document provides specifications for multiple air conditioning models including the GMV-ND28T/C-T, GMV-ND100T/C-T, GMV-ND160T/C-T, and GMV-ND56T/C-T. It includes information on noise levels, electrical specifications, refrigerant type, dimensions, weights and other technical details. Key specifications listed are cooling and heating capacity, airflow, power consumption, pipe diameters and electrical requirements. Units of measurement are provided in both metric and imperial systems.
This document provides specifications for multiple air conditioning models including the GMV-ND28T/C-T, GMV-ND100T/C-T, GMV-ND160T/C-T, and GMV-ND56T/C-T. It includes information on noise levels, electrical specifications, refrigerant type, dimensions, weights and other technical details. Key specifications listed are cooling and heating capacity, airflow, power consumption, pipe diameters and electrical requirements. Units of measurement are provided in both metric and imperial systems.
Series name - - Model designation - - Noise (sound pressure 33 dB(A) 39 dB(A) level) (high)
Noise (sound pressure
30 dB(A) 37 dB(A) level) (medium) Noise (sound pressure 28 dB(A) 34 dB(A) level) (low) Rated voltage 220-240 V 220-240 V Rated frequency 50 Hz 50 Hz Phase 1 - 1 - Power cable (core) 3 N 3 N Circuit breaker 6 A 6 A capacity MOP — A — A MCA — A — A Consumed power 0,026 kW 0,085 kW Refrigerant type R410A - R410A - Standard controller YAP1F - YAP1F - Optional controller XK46 & XK79 & XE70-33/H - XK46 & XK79 & XE70-33/H - Connection method Flare Connection - Flare Connection - IDU loading quantity 120 unit 120 unit (40') IDU loading quantity 140 unit 140 unit (40' HQ) Imperial Metric Imperial British Item Metric system Metric Unit British Unit Metric Unit system system system Unit Cooling capacity 2,8 kW 9,55 kBtu/h 10 kW 34,12 kBtu/h Heating capacity 3,2 kW 10,92 kBtu/h 11,2 kW 38,21 kBtu/h Airflow (high) 800 m3/h 471 CFM 1250 m3/h 736 CFM Airflow (medium) 700 m3/h 412 CFM 1000 m3/h 589 CFM Airflow (low) 600 m3/h 353 CFM 900 m3/h 530 CFM Static pressure 0 Pa 0 Pa outside the unit Cross-sectional area of power line 1 mm2 0,0016 sq in 1 mm2 0,0016 sq in conductor Dimension of gas pipe Φ9.52 mm 3/8 inch Φ15.9 mm 5/8 inch Dimension of liquid Φ6.35 mm 1/4 inch Φ9.52 mm 3/8 inch pipe Flare Flare Flare Flare Connection method - - - - Connection Connection Connection Connection Outline dimensions 840 mm 33 1/16 inch 840 mm 33 1/16 inch (main body) (W) Condensing pipe φ25 mm φ25 mm (outer diameter) Outline dimensions 840 mm 33 1/16 inch 840 mm 33 1/16 inch (main body) (D) Condensing pipe (wall 2,5 mm 2,5 mm thickness) Outline dimensions 240 mm 9 7/16 inch 240 mm 9 7/16 inch (main body) (H) Outline dimensions 1030 mm 40 1/2 inch 1030 mm 40 1/2 inch (front panel) (W) Outline dimensions 1017 mm 40 inch 1017 mm 40 inch (front panel) (D) Outline dimensions 95 mm 3 3/4 inch 95 mm 3 3/4 inch (front panel) (H) Package dimensions 960 mm 37 13/16 inch 960 mm 37 13/16 inch (main body) (L) Package dimensions 960 mm 37 13/16 inch 960 mm 37 13/16 inch (main body) (W) Package dimensions 310 mm 12 13/16 inch 310 mm 12 13/16 inch (main body) (H) Package dimensions 950 mm 37 3/8 inch 950 mm 37 3/8 inch (front panel) (L) Package dimensions 950 mm 37 3/8 inch 950 mm 37 3/8 inch (front panel) (W) Package dimensions 65 mm 2 9/16 inch 65 mm 2 9/16 inch (front panel) (H) Net weight (main body) 27 kg 59,5 lb 29 kg 63,9 lb Net weight (front 6 kg 13,2 lb 6 kg 13,2 lb panel) Gross weight (main 35 kg 77,2 lb 37 kg 81,6 lb body) Gross weight (front 9,5 kg 20,9 lb 9,5 kg 20,9 lb panel) Item Value Unit Value Unit Model GMV-ND160T/C-T - GMV-ND56T/C-T - Series name - - Model designation - - Noise (sound pressure 51 dB(A) 37 dB(A) level) (high)
Noise (sound pressure
48 dB(A) 33 dB(A) level) (medium) Noise (sound pressure 42 dB(A) 30 dB(A) level) (low) Rated voltage 220-240 V 220-240 V Rated frequency 50 Hz 50 Hz Phase 1 - 1 - Power cable (core) 3 N 3 N Circuit breaker 6 A 6 A capacity MOP — A - A MCA — A - A Consumed power 0,17 kW 0,035 kW Refrigerant type R410A - R410A - Standard controller YAP1F - YAP1F - Optional controller XK46 & XK79 & XE70-33/H - XK46 & XK79 & XE70-33/H - Connection method Flare Connection - Flare Connection - IDU loading quantity 120 unit 120 unit (40') IDU loading quantity 140 unit 140 unit (40' HQ) Imperial Metric Imperial British Item Metric system Metric Unit British Unit Metric Unit system system system Unit Cooling capacity 16 kW 54,59 kBtu/h 5,6 kW 19,11 kBtu/h Heating capacity 18 kW 61,42 kBtu/h 6,3 kW 21,5 kBtu/h Airflow (high) 2000 m3/h 1177 CFM 950 m3/h 559 CFM Airflow (medium) 1800 m3/h 1059 CFM 850 m3/h 500 CFM Airflow (low) 1430 m3/h 842 CFM 750 m3/h 441 CFM Static pressure 0 Pa 0 Pa outside the unit Cross-sectional area of power line 1 mm2 0,0016 sq in 1 mm2 0,0016 sq in conductor Dimension of gas pipe Φ19.05 mm 3/4 inch Φ15.9 mm 5/8 inch Dimension of liquid Φ9.52 mm 3/8 inch Φ9.52 mm 3/8 inch pipe Flare Flare Flare Flare Connection method - - - - Connection Connection Connection Connection Outline dimensions 840 mm 33 1/16 inch 840 mm 33 1/16 inch (main body) (W) Condensing pipe φ25 mm φ25 mm (outer diameter) Outline dimensions 840 mm 33 1/16 inch 840 mm 33 1/16 inch (main body) (D) Condensing pipe (wall 2,5 mm 2,5 mm thickness) Outline dimensions 290 mm 11 3/8 inch 240 mm 9 7/16 inch (main body) (H) Outline dimensions 1030 mm 40 1/2 inch 1030 mm 40 1/2 inch (front panel) (W) Outline dimensions 1017 mm 40 inch 1017 mm 40 inch (front panel) (D) Outline dimensions 95 mm 3 3/4 inch 95 mm 3 3/4 inch (front panel) (H) Package dimensions 960 mm 37 13/16 inch 960 mm 37 13/16 inch (main body) (L) Package dimensions 960 mm 37 13/16 inch 960 mm 37 13/16 inch (main body) (W) Package dimensions 364 mm 14 3/8 inch 310 mm 12 13/16 inch (main body) (H) Package dimensions 950 mm 37 3/8 inch 950 mm 37 3/8 inch (front panel) (L) Package dimensions 950 mm 37 3/8 inch 950 mm 37 3/8 inch (front panel) (W) Package dimensions 65 mm 2 9/16 inch 65 mm 2 9/16 inch (front panel) (H) Net weight (main body) 36 kg 79,4 lb 28 kg 61,7 lb Net weight (front 6 kg 13,2 lb 6 kg 13,2 lb panel) Gross weight (main 44 kg 97 lb 36 kg 79,4 lb body) Gross weight (front 9,5 kg 20,9 lb 9,5 kg 20,9 lb panel) Item Value Unit Model GMV-ND160PHS/B-T - Series name - Model designation - Noise (sound pressure 44 dB(A) level) (high)
Noise (sound pressure
41 dB(A) level) (medium) Noise (sound pressure 38 dB(A) level) (low) Rated voltage 220-240 V Rated frequency 50 Hz Phase 1 - Power cable (core) 3 N Circuit breaker 6 A capacity MOP / A MCA / A Consumed power / kW Refrigerant type R410A - Standard controller XK46 - Optional controller YAP1F/YV1L1/XK86/XK79 - Connection method Flare Connection & Brazing - IDU loading quantity 84 unit (40') IDU loading quantity 98 unit (40' HQ) Imperial Item Metric system Metric Unit British Unit system Cooling capacity 16 kW 54,59 kBtu/h Heating capacity 18 kW 61,42 kBtu/h Airflow (high) 2500 m3/h 1471 CFM Airflow (medium) 2000 m3/h 1177 CFM Airflow (low) 1750 m3/h 1030 CFM Static pressure 90/200/0~200 Pa outside the unit Cross-sectional area of power line 1 mm2 0,0016 sq in conductor Dimension of gas pipe Φ19.05 mm 3/4' inch Dimension of liquid Φ9.52 mm 3/8' inch pipe Flare Flare Connection & Connection Connection method - - Brazing & Brazing Connection Connection Outline dimensions 1400 mm 55 1/8 inch (main body) (W) Condensing pipe 25 mm (outer diameter) Outline dimensions 700 mm 27 9/16 inch (main body) (D) Condensing pipe (wall 2,5 mm thickness) Outline dimensions 300 mm 11 13/16 inch (main body) (H) Outline dimensions / mm / inch (front panel) (W) Outline dimensions / mm / inch (front panel) (D) Outline dimensions / mm / inch (front panel) (H) Package dimensions 1675 mm 65 15/16 inch (main body) (L) Package dimensions 805 mm 31 11/16 inch (main body) (W) Package dimensions 350 mm 13 3/4 inch (main body) (H) Package dimensions / mm / inch (front panel) (L) Package dimensions / mm / inch (front panel) (W) Package dimensions / mm / inch (front panel) (H) Net weight (main body) 58 kg 127,9 lb Net weight (front / kg / lb panel) Gross weight (main 67 kg 147,7 lb body) Gross weight (front / kg / lb panel)